HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0072-2020-BRES (38)REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM
QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC
POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY
BACKFLOW PREVENTION ASSEMBLY:FEBCO 825YA
UNCONNECTED PIPE CROSSING
IRRIGATION CONTROLLER UNIT WITHC WR2-RFC WIRELESS RAIN SENSOR AND
IQ NCC COMMUNICATION CARTRIDGE
CONTROLLER A: RAIN BIRD LXMEF; 12 STATIONS IN USE
LATERAL PIPE TO SPRINKLERS:
1-INCH SIZE UNLESS OTHERWISE INDICATED
CLASS 200 PVC
MAINLINE PIPE:CLASS 200 PVC
1.25-INCH SIZE UNLESS OTHERWISE INDICATED
LATERAL PIPE TO DRIP EMITTERS:
3/4-INCH SIZE UNLESS OTHERWISE INDICATED, ROUTING IS DIAGRAMMATIC
UV RADIATION RESISTANT POLYETHYLENE
SLEEVES:CLASS 200 PVC
MASTER VALVE ASSEMBLY:RAIN BIRD PESB
FLUSH CAP ASSEMBLY
POP-UP ROTATING SPRAY SPRINKLER:
PRESSURE: RADIUS:
FLOW (GPM):
LM O HUNTER PROS-06-PRS40-CV W/MP1000 NOZZLES
40 PSI 8 FEET TO 15 FEET
M-0.42 L-0.63 O-0.84
POP-UP ROTATING SPRAY SPRINKLER:
PRESSURE: RADIUS:
FLOW (GPM):
RGK HUNTER PROS-06-PRS40-CV W/MP2000 NOZZLES
40 PSI
K-0.77 G-1.10 R-1.48
13 FEET TO 21 FEET
POP-UP ROTATING SPRAY SPRINKLER:
PRESSURE: RADIUS:
FLOW (GPM):
LST RST SST HUNTER PROS-06-PRS40-CV W/MPSTRIP NOZZLES
40 PSI
SST - 4'X24'-0.34 5'X30'-0.47 LCS/RCS - 4'X12'-0.17 5'X15'-0.23
ADJUSTABLE RECTANGULAR SPRAY
REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS:
RAIN BIRD PEB (SIZED PER PLAN)
FLOW SENSOR ASSEMBLY:F RAIN BIRD FS100B
I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND APPLIED THEM ACCORDINGLY
FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN.
EDWARD W PRICE, CID, CLIA DATE
1.APPLICANT IS RESPONSIBLE FOR ASSURING OPERATING PRESSURE AT EACH
EMISSION DEVICE IS WITHIN THE MANUFACTURER'S RECOMMENDED PRESSURE
RANGE FOR OPTIMAL PERFORMANCE. IF PRESSURE IS NOT WITHIN THE
PREFERRED RANGE, ACTIONS DESCRIBED IN SECTION 5.1.11 OF THE WATER
EFFICIENT LANDSCAPING STANDARDS MUST BE TAKEN.
2.SPRINKLERS WITHIN INDIVIDUAL IRRIGATION ZONE SHALL HAVE MATCHED
PRECIPITATION RATES, UNLESS OTHERWISE DIRECTED BY THE
MANUFACTURER'S RECOMMENDATIONS.
3.SLOPES GREATER THAN TWENTY-FIVE PERCENT (25%) SHALL NOT USE
SPRINKLERS WITH AN APPLICATION RATE EXCEEDING 0.75 INCHES PER HOUR.
REFER TO CITY OF ASPEN WATER EFFICIENT LANDSCAPING STANDARDS
SECTION 5.2.4 FOR EXCEPTIONS, AND TO SECTION 5.5 FOR LANDSCAPE
SCHEDULING TO PREVENT RUNOFF.
4.REMOVING VEGETATION OR AMENDING SOIL UNDER EXISTING TREES REQUIRES
HAND GRUBBING NO DEEPER THAN FOUR INCHES (4") WITH ADDITIONAL SOIL
ABOVE EXISTING GRADE LIMITED TO A MAXIMUM OF THREE INCHES (3").
IRRIGATION WORK PERFORMED WITHIN THE DRIP LINE OF EXISTING TREES
REQUIRES HAND GRUBBING AS FAR FROM TREE TRUNKS AS PRACTICALLY
POSSIBLE, NO DEEPER THAN THREE INCHES (3"). DO NOT CUT ROOTS LARGER
THAN TWO INCHES (2") IN DIAMETER.
5.AN IRRIGATION MAINTENANCE SCHEDULE AND IRRIGATION MANAGEMENT
PLAN IS REQUIRED AS DESCRIBED IN SECTIONS 5.4 THROUGH 5.8 OF THE
ASPEN WATER EFFICIENT LANDSCAPING STANDARDS.
ENSURE THE FOLLOWING:
1.TURF GRASS SPRINKLER HEADS SHALL HAVE A DISTRIBUTION UNIFORMITY OF
0.65 OR HIGHER USING THE PROTOCOL DEFINED IN ASABE/ICC 802-2014.
2.POP-UPS IN TURF AREAS HAVE A MINIMUM HEIGHT OF 6".
ID#: 50322
06/26/2020
CITY OF ASPEN GENERAL NOTES
LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3
A1141"
INDICATES LATERAL DISCHARGE (GPM)
INDICATES VALVE SIZE (INCHES)
INDICATES CONTROLLER AND STATION NUMBER
INDICATES ZONE DESIGN PRESSURE (PSI)
INDICATES PRECIP. RATE (INCHES PER HOUR)0.50
30
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY
OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW
PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, SAME
SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S
REPRESENTATIVE.
WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE
LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER
WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL
THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR
MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS,
NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL LOCATION TO BE
APPROVED BY OWNER'S REPRESENTATIVE.
THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION
GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION
DEVICE AT THE APPROXIMATE LOCATION SHOWN, PER CITY OF ASPEN
REQUIREMENTS.
SEE GREENROOF OVER GARAGE
THE IRRIGATION CONTRACTOR SHALL ROUTE DRIP LATERAL TO THE
APPROXIMATE LOCATION SHOWN; COORDINATE WITH MECHANICAL
ENGINEER FOR PIPE MATERIAL TRANSITION AND ROUTING TO GREEN ROOF.
THE IRRIGATION CONTRACTOR SHALL MINIMIZE DISTURBANCE OF TREE
ROOTS IN THIS AREA. PURSUANT TO WELS SECTION 4.3.2 (L & M), THE CITY
FORESTER MUST REVIEW AND APPROVE ANY DISTURBANCE WITHIN THE
DRIPLINES OF EXISTING TREES.
ALTHOUGH TREES AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS
ARE IRRIGATED ON THE SAME DRIP ZONE, THE CONTRACTOR SHALL REFER
TO THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE
CORRECT SIZE AND QUANTITY OF EMITTERS PER PLANT WATER
REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES
AND WATER REQUIREMENTS.
CONSTRUCTION NOTES
1
2
3
IRRIGATION LEGEND
1.THE SYSTEM DESIGN ASSUMES A MINIMUM PRESSURE FOR THE IRRIGATION SYSTEM OF 70 PSI ,
AT A MAXIMUM DISCHARGE OF 12 GPM AT THE 3/4-INCH IRRIGATION POINT-OF-CONNECTION
(POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION.
2.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION
DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION.
3.COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION.
4.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN
THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN
CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND,
NOTES, OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR
DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE.
5.THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED:
A.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR
CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER
POSSIBLE.
B.TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER
IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION
SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES.
C.USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE
CONFIGURATION, OR USE OF CROSS TYPE FITTINGS IS NOT ALLOWED.
6.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE
PROJECT:
A.TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES.
B.TWO (2) OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS,
ADJUSTMENT, AND REPAIR OF ALL ROTARY SPRINKLERS.
7.SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE
AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS.
CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY
SPRINKLER TO PROVIDE THE BEST PERFORMANCE.
8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION
SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH
HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY
PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT
INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. PIPE
SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE OF THE PIPE PASSING THROUGH.
9.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH
THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES.
10.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS
LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME
NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED
WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND.
11.INSTALL TWO (2) #14 AWG CONTROL WIRES, FOR USE AS SPARES. INSTALL SPARE WIRES FROM
CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX.
12.THE IRRIGATION CONTRACTOR SHALL USE FLOW CONTROL ON ALL ZONE CONTROL VALVES TO
ACHIEVE DESIGN PRESSURE AT MOST REMOTE OR HIGHEST ELEVATION EMISSION DEVICE ON
EACH ZONE. SEE LEGEND AND VALVE DESIGNATORS FOR EQUIPMENT DESIGN PRESSURE.
13.ALTHOUGH TREES AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS ARE IRRIGATED ON
THE SAME DRIP ZONE, THE CONTRACTOR SHALL REFER TO THE EMITTER SCHEDULE IN THE
IRRIGATION DETAILS TO INSTALL THE CORRECT SIZE AND QUANTITY OF EMITTERS PER PLANT
WATER REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES AND
WATER REQUIREMENTS.
14.SENSORS (E.G., RAIN, FREEZE, WIND, AND/OR SOIL MOISTURE ETC.), EITHER INTEGRAL OR
AUXILIARY, THAT SUSPEND OR ALTER IRRIGATION OPERATION DURING UNFAVORABLE
WEATHER CONDITIONS OR WHEN SUFFICIENT SOIL MOISTURE IS PRESENT SHALL BE REQUIRED
ON ALL IRRIGATION SYSTEMS.
INSTALLATION GENERAL NOTES
4
5
6
SOIL MOISTURE SENSOR:HUNTER SOIL-CLIK
7
85
5
C
h
a
t
f
i
e
l
d
R
o
a
d
IR-1.0
scale:
3/16" = 1' - 0"
e
l
e
m
e
n
t
s
Irrigation Legend and Notes
Ch
a
t
f
i
e
l
d
V
i
e
w
As
p
e
n
,
C
o
l
o
r
a
d
o
8
1
6
1
1
~03.15.2020 SD
~06.02.2020 DD
~06.26.2020 permit
~12.23.2020 permit
12/30/2020
K KK
KK K
KKRMM
MM
L
M
M
M
M
M
ML
M
M
M
M
M
M
M
M
M
C
F
C3
Drip
0.15
1"
C4
6.76
0.51
1"
C1
Drip
0.15
1"
C5
Drip
0.15
1"
C6
Drip
0.15
1"
C7
6.73
0.41
1"
C8
Drip
0.15
1"
C12
8.15
0.57
1"
C11
Drip
0.15
1"
CONTROLLER
120 VAC POWER REQUIRED
2
POC
SIZE: 3/4-INCH
PRESSURE: 70 PSI
FLOW: 12 GPM
1
30PSI
40PSI
30PSI
30PSI30PSI
40PSI30PSI
40PSI
30PSI
3
4
5
6
6
6
6
6
M
M
M
MM
M
G
K M
M
K
B
M
M
M MM
M
M
C2
Drip
0.15
1"
C9
Drip
0.15
1"
30PSI
C13
Drip
0.15
1"
C14
Drip
0.15
1"
30PSI
30PSI
30PSI
7
B
B
K
KK
K
K
K
M
M
M
M
M
M
M
M
RST SST
SST
SST
SST
C15
11.7
0.60
1"
40PSI
C10
Drip
0.15
1"
30PSI
7
6
REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM
QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC
POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY
BACKFLOW PREVENTION ASSEMBLY:FEBCO 825YA
UNCONNECTED PIPE CROSSING
IRRIGATION CONTROLLER UNIT WITHC WR2-RFC WIRELESS RAIN SENSOR AND
IQ NCC COMMUNICATION CARTRIDGE
CONTROLLER A: RAIN BIRD LXMEF; 12 STATIONS IN USE
LATERAL PIPE TO SPRINKLERS:
1-INCH SIZE UNLESS OTHERWISE INDICATED
CLASS 200 PVC
MAINLINE PIPE:CLASS 200 PVC
1.25-INCH SIZE UNLESS OTHERWISE INDICATED
LATERAL PIPE TO DRIP EMITTERS:
3/4-INCH SIZE UNLESS OTHERWISE INDICATED, ROUTING IS DIAGRAMMATIC
UV RADIATION RESISTANT POLYETHYLENE
SLEEVES:CLASS 200 PVC
MASTER VALVE ASSEMBLY:RAIN BIRD PESB
FLUSH CAP ASSEMBLY
POP-UP ROTATING SPRAY SPRINKLER:
PRESSURE: RADIUS:
FLOW (GPM):
LM O HUNTER PROS-06-PRS40-CV W/MP1000 NOZZLES
40 PSI 8 FEET TO 15 FEET
M-0.42 L-0.63 O-0.84
POP-UP ROTATING SPRAY SPRINKLER:
PRESSURE: RADIUS:
FLOW (GPM):
RGK HUNTER PROS-06-PRS40-CV W/MP2000 NOZZLES
40 PSI
K-0.77 G-1.10 R-1.48
13 FEET TO 21 FEET
POP-UP ROTATING SPRAY SPRINKLER:
PRESSURE: RADIUS:
FLOW (GPM):
LST RST SST HUNTER PROS-06-PRS40-CV W/MPSTRIP NOZZLES
40 PSI
SST - 4'X24'-0.34 5'X30'-0.47 LCS/RCS - 4'X12'-0.17 5'X15'-0.23
ADJUSTABLE RECTANGULAR SPRAY
REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS:
RAIN BIRD PEB (SIZED PER PLAN)
FLOW SENSOR ASSEMBLY:F RAIN BIRD FS100B
ID#: 50322
LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3
A1141"
INDICATES LATERAL DISCHARGE (GPM)
INDICATES VALVE SIZE (INCHES)
INDICATES CONTROLLER AND STATION NUMBER
INDICATES ZONE DESIGN PRESSURE (PSI)
INDICATES PRECIP. RATE (INCHES PER HOUR)0.50
30
IRRIGATION LEGEND
SOIL MOISTURE SENSOR:HUNTER SOIL-CLIK
SEE ABOVE
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY
OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW
PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, SAME
SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S
REPRESENTATIVE.
WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE
LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER
WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL
THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR
MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS,
NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL LOCATION TO BE
APPROVED BY OWNER'S REPRESENTATIVE.
THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION
GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION
DEVICE AT THE APPROXIMATE LOCATION SHOWN, PER CITY OF ASPEN
REQUIREMENTS.
SEE GREENROOF OVER GARAGE
THE IRRIGATION CONTRACTOR SHALL ROUTE DRIP LATERAL TO THE
APPROXIMATE LOCATION SHOWN; COORDINATE WITH MECHANICAL
ENGINEER FOR PIPE MATERIAL TRANSITION AND ROUTING TO GREEN ROOF.
THE IRRIGATION CONTRACTOR SHALL MINIMIZE DISTURBANCE OF TREE
ROOTS IN THIS AREA. PURSUANT TO WELS SECTION 4.3.2 (L & M), THE CITY
FORESTER MUST REVIEW AND APPROVE ANY DISTURBANCE WITHIN THE
DRIPLINES OF EXISTING TREES.
ALTHOUGH TREES AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS
ARE IRRIGATED ON THE SAME DRIP ZONE, THE CONTRACTOR SHALL REFER
TO THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE
CORRECT SIZE AND QUANTITY OF EMITTERS PER PLANT WATER
REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES
AND WATER REQUIREMENTS.
CONSTRUCTION NOTES
1
2
3
4
5
6
7
85
5
C
h
a
t
f
i
e
l
d
R
o
a
d
IR-2.0
north
scale:
1/8" = 1' - 0"
e
l
e
m
e
n
t
s
~03.15.2020 SD
Irrigation plan -
lower & main level
Ch
a
t
f
i
e
l
d
V
i
e
w
As
p
e
n
,
C
o
l
o
r
a
d
o
8
1
6
1
1
ch
a
t
f
i
e
l
d
r
o
a
d
~06.02.2020 DD
~06.26.2020 permit
GREENROOF OVER GARAGE
~12.23.2020 permit
12/30/2020
85
5
C
h
a
t
f
i
e
l
d
R
o
a
d
IR-3.0
scale:
N.T.S.
e
l
e
m
e
n
t
s
Irrigation details
Ch
a
t
f
i
e
l
d
V
i
e
w
As
p
e
n
,
C
o
l
o
r
a
d
o
8
1
6
1
1
~03.15.2020 SD
~06.02.2020 DD
~06.26.2020 permit
1 2 4
6 87
9
FLOW SENSOR
ASSEMBLY
ISOLATION GATE VALVE ASSEMBLY
2.5-INCH MAINLINE AND SMALLER
QUICK COUPLING
VALVE ASSEMBLY
REMOTE CONTROL TURF
VALVE ASSEMBLY
REMOTE CONTROL DRIP
VALVE ASSEMBLY
6-INCH POP UP
MP-ROTATOR ASSEMBLY
SINGLE OUTLET DRIP
EMITTER ASSEMBLY
MASTER VALVE
ASSEMBLY 3
EMITTER SCHEDULE11
BACKFLOW PREVENTION
UNIT ASSEMBLY
5
10 MULTI-OUTLET DRIP EMITTER
ASSEMBLY FOR TREES IN BEDS
~12.23.2020 permit
12/30/2020
85
5
C
h
a
t
f
i
e
l
d
R
o
a
d
IR-4.0
scale:
N.T.S.
e
l
e
m
e
n
t
s
Irrigation details
Ch
a
t
f
i
e
l
d
V
i
e
w
As
p
e
n
,
C
o
l
o
r
a
d
o
8
1
6
1
1
~03.15.2020 SD
~06.02.2020 DD
~06.26.2020 permit
11 12DRIP FLUSH CAP
ASSEMBLY
WALL MOUNT
CONTROLLER ASSEMBLY
TYPICAL TRENCHING
DETAIL14 TYPICAL SLEEVING
DETAIL15 16 TYPICAL VALVE BOX
INSTALLATION
RCV
A1
RCV
A2
RCV
A3
QC
13
PLAN VIEWPROFILE VIEW
TYPICAL IRRIGATION CONTROLLER GROUNDING
ROD OR PLATE INSTALLATION
~12.23.2020 permit
12/30/2020