HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0072-2020-BRES (38)REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY BACKFLOW PREVENTION ASSEMBLY:FEBCO 825YA UNCONNECTED PIPE CROSSING IRRIGATION CONTROLLER UNIT WITHC WR2-RFC WIRELESS RAIN SENSOR AND IQ NCC COMMUNICATION CARTRIDGE CONTROLLER A: RAIN BIRD LXMEF; 12 STATIONS IN USE LATERAL PIPE TO SPRINKLERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC MAINLINE PIPE:CLASS 200 PVC 1.25-INCH SIZE UNLESS OTHERWISE INDICATED LATERAL PIPE TO DRIP EMITTERS: 3/4-INCH SIZE UNLESS OTHERWISE INDICATED, ROUTING IS DIAGRAMMATIC UV RADIATION RESISTANT POLYETHYLENE SLEEVES:CLASS 200 PVC MASTER VALVE ASSEMBLY:RAIN BIRD PESB FLUSH CAP ASSEMBLY POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LM O HUNTER PROS-06-PRS40-CV W/MP1000 NOZZLES 40 PSI 8 FEET TO 15 FEET M-0.42 L-0.63 O-0.84 POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): RGK HUNTER PROS-06-PRS40-CV W/MP2000 NOZZLES 40 PSI K-0.77 G-1.10 R-1.48 13 FEET TO 21 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LST RST SST HUNTER PROS-06-PRS40-CV W/MPSTRIP NOZZLES 40 PSI SST - 4'X24'-0.34 5'X30'-0.47 LCS/RCS - 4'X12'-0.17 5'X15'-0.23 ADJUSTABLE RECTANGULAR SPRAY REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: RAIN BIRD PEB (SIZED PER PLAN) FLOW SENSOR ASSEMBLY:F RAIN BIRD FS100B I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPING STANDARDS AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE IRRIGATION DESIGN PLAN. EDWARD W PRICE, CID, CLIA DATE 1.APPLICANT IS RESPONSIBLE FOR ASSURING OPERATING PRESSURE AT EACH EMISSION DEVICE IS WITHIN THE MANUFACTURER'S RECOMMENDED PRESSURE RANGE FOR OPTIMAL PERFORMANCE. IF PRESSURE IS NOT WITHIN THE PREFERRED RANGE, ACTIONS DESCRIBED IN SECTION 5.1.11 OF THE WATER EFFICIENT LANDSCAPING STANDARDS MUST BE TAKEN. 2.SPRINKLERS WITHIN INDIVIDUAL IRRIGATION ZONE SHALL HAVE MATCHED PRECIPITATION RATES, UNLESS OTHERWISE DIRECTED BY THE MANUFACTURER'S RECOMMENDATIONS. 3.SLOPES GREATER THAN TWENTY-FIVE PERCENT (25%) SHALL NOT USE SPRINKLERS WITH AN APPLICATION RATE EXCEEDING 0.75 INCHES PER HOUR. REFER TO CITY OF ASPEN WATER EFFICIENT LANDSCAPING STANDARDS SECTION 5.2.4 FOR EXCEPTIONS, AND TO SECTION 5.5 FOR LANDSCAPE SCHEDULING TO PREVENT RUNOFF. 4.REMOVING VEGETATION OR AMENDING SOIL UNDER EXISTING TREES REQUIRES HAND GRUBBING NO DEEPER THAN FOUR INCHES (4") WITH ADDITIONAL SOIL ABOVE EXISTING GRADE LIMITED TO A MAXIMUM OF THREE INCHES (3"). IRRIGATION WORK PERFORMED WITHIN THE DRIP LINE OF EXISTING TREES REQUIRES HAND GRUBBING AS FAR FROM TREE TRUNKS AS PRACTICALLY POSSIBLE, NO DEEPER THAN THREE INCHES (3"). DO NOT CUT ROOTS LARGER THAN TWO INCHES (2") IN DIAMETER. 5.AN IRRIGATION MAINTENANCE SCHEDULE AND IRRIGATION MANAGEMENT PLAN IS REQUIRED AS DESCRIBED IN SECTIONS 5.4 THROUGH 5.8 OF THE ASPEN WATER EFFICIENT LANDSCAPING STANDARDS. ENSURE THE FOLLOWING: 1.TURF GRASS SPRINKLER HEADS SHALL HAVE A DISTRIBUTION UNIFORMITY OF 0.65 OR HIGHER USING THE PROTOCOL DEFINED IN ASABE/ICC 802-2014. 2.POP-UPS IN TURF AREAS HAVE A MINIMUM HEIGHT OF 6". ID#: 50322 06/26/2020 CITY OF ASPEN GENERAL NOTES LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3 A1141" INDICATES LATERAL DISCHARGE (GPM) INDICATES VALVE SIZE (INCHES) INDICATES CONTROLLER AND STATION NUMBER INDICATES ZONE DESIGN PRESSURE (PSI) INDICATES PRECIP. RATE (INCHES PER HOUR)0.50 30 THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION DEVICE AT THE APPROXIMATE LOCATION SHOWN, PER CITY OF ASPEN REQUIREMENTS. SEE GREENROOF OVER GARAGE THE IRRIGATION CONTRACTOR SHALL ROUTE DRIP LATERAL TO THE APPROXIMATE LOCATION SHOWN; COORDINATE WITH MECHANICAL ENGINEER FOR PIPE MATERIAL TRANSITION AND ROUTING TO GREEN ROOF. THE IRRIGATION CONTRACTOR SHALL MINIMIZE DISTURBANCE OF TREE ROOTS IN THIS AREA. PURSUANT TO WELS SECTION 4.3.2 (L & M), THE CITY FORESTER MUST REVIEW AND APPROVE ANY DISTURBANCE WITHIN THE DRIPLINES OF EXISTING TREES. ALTHOUGH TREES AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS ARE IRRIGATED ON THE SAME DRIP ZONE, THE CONTRACTOR SHALL REFER TO THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE CORRECT SIZE AND QUANTITY OF EMITTERS PER PLANT WATER REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES AND WATER REQUIREMENTS. CONSTRUCTION NOTES 1 2 3 IRRIGATION LEGEND 1.THE SYSTEM DESIGN ASSUMES A MINIMUM PRESSURE FOR THE IRRIGATION SYSTEM OF 70 PSI , AT A MAXIMUM DISCHARGE OF 12 GPM AT THE 3/4-INCH IRRIGATION POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 2.READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 3.COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 4.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 5.THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. B.TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. C.USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE CONFIGURATION, OR USE OF CROSS TYPE FITTINGS IS NOT ALLOWED. 6.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A.TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES. B.TWO (2) OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS, ADJUSTMENT, AND REPAIR OF ALL ROTARY SPRINKLERS. 7.SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE OF THE PIPE PASSING THROUGH. 9.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 11.INSTALL TWO (2) #14 AWG CONTROL WIRES, FOR USE AS SPARES. INSTALL SPARE WIRES FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX. 12.THE IRRIGATION CONTRACTOR SHALL USE FLOW CONTROL ON ALL ZONE CONTROL VALVES TO ACHIEVE DESIGN PRESSURE AT MOST REMOTE OR HIGHEST ELEVATION EMISSION DEVICE ON EACH ZONE. SEE LEGEND AND VALVE DESIGNATORS FOR EQUIPMENT DESIGN PRESSURE. 13.ALTHOUGH TREES AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS ARE IRRIGATED ON THE SAME DRIP ZONE, THE CONTRACTOR SHALL REFER TO THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE CORRECT SIZE AND QUANTITY OF EMITTERS PER PLANT WATER REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES AND WATER REQUIREMENTS. 14.SENSORS (E.G., RAIN, FREEZE, WIND, AND/OR SOIL MOISTURE ETC.), EITHER INTEGRAL OR AUXILIARY, THAT SUSPEND OR ALTER IRRIGATION OPERATION DURING UNFAVORABLE WEATHER CONDITIONS OR WHEN SUFFICIENT SOIL MOISTURE IS PRESENT SHALL BE REQUIRED ON ALL IRRIGATION SYSTEMS. INSTALLATION GENERAL NOTES 4 5 6 SOIL MOISTURE SENSOR:HUNTER SOIL-CLIK 7 85 5 C h a t f i e l d R o a d IR-1.0 scale: 3/16" = 1' - 0" e l e m e n t s Irrigation Legend and Notes Ch a t f i e l d V i e w As p e n , C o l o r a d o 8 1 6 1 1 ~03.15.2020 SD ~06.02.2020 DD ~06.26.2020 permit ~12.23.2020 permit 12/30/2020 K KK KK K KKRMM MM L M M M M M ML M M M M M M M M M C F C3 Drip 0.15 1" C4 6.76 0.51 1" C1 Drip 0.15 1" C5 Drip 0.15 1" C6 Drip 0.15 1" C7 6.73 0.41 1" C8 Drip 0.15 1" C12 8.15 0.57 1" C11 Drip 0.15 1" CONTROLLER 120 VAC POWER REQUIRED 2 POC SIZE: 3/4-INCH PRESSURE: 70 PSI FLOW: 12 GPM 1 30PSI 40PSI 30PSI 30PSI30PSI 40PSI30PSI 40PSI 30PSI 3 4 5 6 6 6 6 6 M M M MM M G K M M K B M M M MM M M C2 Drip 0.15 1" C9 Drip 0.15 1" 30PSI C13 Drip 0.15 1" C14 Drip 0.15 1" 30PSI 30PSI 30PSI 7 B B K KK K K K M M M M M M M M RST SST SST SST SST C15 11.7 0.60 1" 40PSI C10 Drip 0.15 1" 30PSI 7 6 REMOTE CONTROL DRIP VALVE ASSEMBLY:RAIN BIRD XCZ-PRB-100-COM QUICK COUPLING VALVE ASSEMBLY:RAIN BIRD 5RC POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY BACKFLOW PREVENTION ASSEMBLY:FEBCO 825YA UNCONNECTED PIPE CROSSING IRRIGATION CONTROLLER UNIT WITHC WR2-RFC WIRELESS RAIN SENSOR AND IQ NCC COMMUNICATION CARTRIDGE CONTROLLER A: RAIN BIRD LXMEF; 12 STATIONS IN USE LATERAL PIPE TO SPRINKLERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC MAINLINE PIPE:CLASS 200 PVC 1.25-INCH SIZE UNLESS OTHERWISE INDICATED LATERAL PIPE TO DRIP EMITTERS: 3/4-INCH SIZE UNLESS OTHERWISE INDICATED, ROUTING IS DIAGRAMMATIC UV RADIATION RESISTANT POLYETHYLENE SLEEVES:CLASS 200 PVC MASTER VALVE ASSEMBLY:RAIN BIRD PESB FLUSH CAP ASSEMBLY POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LM O HUNTER PROS-06-PRS40-CV W/MP1000 NOZZLES 40 PSI 8 FEET TO 15 FEET M-0.42 L-0.63 O-0.84 POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): RGK HUNTER PROS-06-PRS40-CV W/MP2000 NOZZLES 40 PSI K-0.77 G-1.10 R-1.48 13 FEET TO 21 FEET POP-UP ROTATING SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): LST RST SST HUNTER PROS-06-PRS40-CV W/MPSTRIP NOZZLES 40 PSI SST - 4'X24'-0.34 5'X30'-0.47 LCS/RCS - 4'X12'-0.17 5'X15'-0.23 ADJUSTABLE RECTANGULAR SPRAY REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: RAIN BIRD PEB (SIZED PER PLAN) FLOW SENSOR ASSEMBLY:F RAIN BIRD FS100B ID#: 50322 LOCKABLE VALVE PER ASPEN WELS SECTION 5.1.3 A1141" INDICATES LATERAL DISCHARGE (GPM) INDICATES VALVE SIZE (INCHES) INDICATES CONTROLLER AND STATION NUMBER INDICATES ZONE DESIGN PRESSURE (PSI) INDICATES PRECIP. RATE (INCHES PER HOUR)0.50 30 IRRIGATION LEGEND SOIL MOISTURE SENSOR:HUNTER SOIL-CLIK SEE ABOVE THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE IRRIGATION WATER TAP AND METER INSTALLED BY OTHERS AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTER VALVE ASSEMBLY AS INDICATED, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION GATE VALVE ASSEMBLY DOWNSTREAM OF THE BACKFLOW PREVENTION DEVICE AT THE APPROXIMATE LOCATION SHOWN, PER CITY OF ASPEN REQUIREMENTS. SEE GREENROOF OVER GARAGE THE IRRIGATION CONTRACTOR SHALL ROUTE DRIP LATERAL TO THE APPROXIMATE LOCATION SHOWN; COORDINATE WITH MECHANICAL ENGINEER FOR PIPE MATERIAL TRANSITION AND ROUTING TO GREEN ROOF. THE IRRIGATION CONTRACTOR SHALL MINIMIZE DISTURBANCE OF TREE ROOTS IN THIS AREA. PURSUANT TO WELS SECTION 4.3.2 (L & M), THE CITY FORESTER MUST REVIEW AND APPROVE ANY DISTURBANCE WITHIN THE DRIPLINES OF EXISTING TREES. ALTHOUGH TREES AND SHRUBS WITH DIFFERENT WATER REQUIREMENTS ARE IRRIGATED ON THE SAME DRIP ZONE, THE CONTRACTOR SHALL REFER TO THE EMITTER SCHEDULE IN THE IRRIGATION DETAILS TO INSTALL THE CORRECT SIZE AND QUANTITY OF EMITTERS PER PLANT WATER REQUIREMENTS. REFER TO LANDSCAPE PLANS FOR SPECIFIC PLANT SPECIES AND WATER REQUIREMENTS. CONSTRUCTION NOTES 1 2 3 4 5 6 7 85 5 C h a t f i e l d R o a d IR-2.0 north scale: 1/8" = 1' - 0" e l e m e n t s ~03.15.2020 SD Irrigation plan - lower & main level Ch a t f i e l d V i e w As p e n , C o l o r a d o 8 1 6 1 1 ch a t f i e l d r o a d ~06.02.2020 DD ~06.26.2020 permit GREENROOF OVER GARAGE ~12.23.2020 permit 12/30/2020 85 5 C h a t f i e l d R o a d IR-3.0 scale: N.T.S. e l e m e n t s Irrigation details Ch a t f i e l d V i e w As p e n , C o l o r a d o 8 1 6 1 1 ~03.15.2020 SD ~06.02.2020 DD ~06.26.2020 permit 1 2 4 6 87 9 FLOW SENSOR ASSEMBLY ISOLATION GATE VALVE ASSEMBLY 2.5-INCH MAINLINE AND SMALLER QUICK COUPLING VALVE ASSEMBLY REMOTE CONTROL TURF VALVE ASSEMBLY REMOTE CONTROL DRIP VALVE ASSEMBLY 6-INCH POP UP MP-ROTATOR ASSEMBLY SINGLE OUTLET DRIP EMITTER ASSEMBLY MASTER VALVE ASSEMBLY 3 EMITTER SCHEDULE11 BACKFLOW PREVENTION UNIT ASSEMBLY 5 10 MULTI-OUTLET DRIP EMITTER ASSEMBLY FOR TREES IN BEDS ~12.23.2020 permit 12/30/2020 85 5 C h a t f i e l d R o a d IR-4.0 scale: N.T.S. e l e m e n t s Irrigation details Ch a t f i e l d V i e w As p e n , C o l o r a d o 8 1 6 1 1 ~03.15.2020 SD ~06.02.2020 DD ~06.26.2020 permit 11 12DRIP FLUSH CAP ASSEMBLY WALL MOUNT CONTROLLER ASSEMBLY TYPICAL TRENCHING DETAIL14 TYPICAL SLEEVING DETAIL15 16 TYPICAL VALVE BOX INSTALLATION RCV A1 RCV A2 RCV A3 QC 13 PLAN VIEWPROFILE VIEW TYPICAL IRRIGATION CONTROLLER GROUNDING ROD OR PLATE INSTALLATION ~12.23.2020 permit 12/30/2020