Loading...
HomeMy WebLinkAboutFile Documents.855 Chatfield Rd.0072-2020-BRES (47)1/2" THICK POOL FINISH RE: TYPICAL WALL DETAIL FOR CONCRETE & REBAR SPECIFICATIONS WATER LEVEL VERTICAL SECTION SUCTION LINE RE: PIPE DIAGRAM PLAN SECTION 1' - 4" SKIMMER; RE: DATA SKIMMER RE: DATA 6" SKIMMER RECESSED 3" INTO WALL & FULLY TILED COPING; RE: DATA 1' - 4" 3" SKIMMER THROAT FULLY TILED 9" 3" DIRECTIONAL EYEBALL RE: DATA FOR SIZE POOL WALL FINISH EYEBALL RETAINER 1 1/2" SCHEDULE 40 PVC GREENSTREAK, LOCKSTOP NON-SHRINK, MASTIC WATER STOP POOL WALL DE F A U L T 1 8 " B E L O W W A T E R L E V E L RE : T O S E C T I O N STRUCTURAL INSTALLATION NOTES: GOVERNING BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE. 1. CONTRACTOR MUST VERIFY THE LOCATION OF ANY EXISTING BUILDING FOUNDATIONS AND UNDERGROUND UTILITIES PRIOR TO EXCAVATING FOR SPA CONSTRUCTION. ANY ADJACENT BUILDING FOOTINGS SHALL BE AT OR BELOW THE BOTTOM OF THE POOL SHELL AND AT A DISTANCE SPECIFIED BY THE BUILDING STRUCTURAL ENGINEER (ANY FOOTING WITHIN 3 FEET OF POOL SHELL MUST BE VERIFIED BY BUILDING STRUCTURAL ENGINEER. GEOTECHNICAL RECOMMENDATIONS: THE SPA HEREIN HAS BEEN DESIGNED IN ACCORDANCE TO GUIDANCE PROVIDED BY THE PROJECT GEOTECHNICAL REPORT ISSUED BY: H-P KUMAR, PROJECT NO. 18-7-516, DATED SEPTEMBER 5, 2018 DESIGN LATERAL SOIL PRESSURES: 45 PCF ALLOWABLE BEARING PRESSURE: 3500 PCF BACKFILL SPA SHELL WITH CLEAN, IMPORTED, GRANULAR SOIL SUCH AS SAND OR ROCK. REFER TO GEOTECHNICAL REPORT FOR ADDITIONAL RECOMMENDATIONS. CONCRETE AND REINFORCEMENT: USE TYPE II CEMENT SHOTCRETE SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF THE LATEST EDITION OF ACI-301. MINIMUM 28 DAY COMPRESSIVE STRENGHT SHALL BE 4,500 PSI. SHOTCRETE SHALL BE PLACED AGAINST FIRM, NATURAL, UNDISTURBED SOIL, COMPACTED ENGINEER FILL OR FORMS. STEEL REINFORCING FOR THE SPA STRUCTURE SHALL BE ASTM GRADE 60 AND IN ACCORDANCE WITH THE ACI DETAILING MANUAL OF STANDARD PRACTICE. UNLESS SPECIFICALLY NOTED OTHERWISE, STEEL REINFORCEMENT SHALL BE INSTALLED PER CHAPTER 25 AND SECTION 26.6 OF ACI 318-14. SPLICE LENGTH, DOWEL PROTECTION OR EMBEDMENT SHALL BE AS SPECIFIED IN 6/PL1.0 MAINTAIN CONTINUITY OF ALL HORIZONTAL REINFORCEMENT AT CORNERS, INTERSECTIONS AND AT STEPS AND BENCHES. MINIMUM CONCRETE COVERAGE FOR REBAR: -1 1/2" NOT EXPOSED TO WEATHER IN CONTACT WITH THE GROUND. -2" CONCRETE EXPOSED TO EARTH OR WEATHER. -3" CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. GENERAL NOTES: SPA SHALL BE PLACED OVER A MIN. FREE DRAINING GRAVEL. REFER TO 6/PL1.0 FOR ADDITIONAL DETAILS & REQUIREMENTS. NOTES: 1. TYPICAL FOR ALL OPENINGS IN CONCRETE WALLS & SLAB UNLESS INDICATED OTHERWISE ON PLANS. 2. DO NOT WELD REINFORCEMENT TO PIPE SLEEVES AND INSERTS. 3. ALL OPENINGS THROUGH WATERTIGHT TANK REQUIRE WATERSTOP. PROVIDE MINIMUM LAP AS NOTED OR SHOWN ON PLANS (TYP.) ADD 1-#5x4'-0" DIAG. @ EACH CORNER FOR EACH LAYER OF REINFORCING AREA OF BARS EQUAL BAND "A" BARS CUT 1-#5 HOOP, DIA. OF OPENING + 8", IN EACH LAYER OF REINF'G FOR OPENINGS LARGER THAN 8". AREA OF BARS EQUAL BAND "A" BARS CUT STEEL REINF. CUT BAND "A" STEEL REINF. CUT BAND "B" SEE STRUCTURAL NOTES FOR REQUIREMENTS NOTE: CORNER BAR TO MATCH PRIMARY HORIZ. REINFORCING LAP LENGTH LA P L E N G T H SE E S T R U C T U R A L N O T E S FO R R E Q U I R E M E N T S REMOVABLE COPING STONE TO MATCH DECK; COORDINATE THICKNESS WITH GC. STAINLESS STEEL SUPPORT BRACKET BY COVER MANUF. WATER LEVEL DECK SLAB & FINISH BY OTHERS POOL AUTO COVER RE: DATA WATERLINE TILE POOL PLASTER FINISH #4 "Z" BARS @ 8" O.C. DOUBLE MAT #4 @ 16" O.C. EA. WAY. RE: 2/PL1.1 IN AUTOCOLOR WALL ONLY. USE RE: 2/PL 1.1 REFER TO COVER MANUF. 3" COVER BOX DRAIN TO DAY LIGHT#4 HORIZ. BARS @ 8" O.C. 6" 1' - 0"6" REFER TO 3/PL2.1 FOR MANUF. DIMENSIONS/DETAILS WALL THICKNESS AT AUTOCOVER WALL ONLY. RE: 2/PL1.1 FOR ALL OTHER WALLS. INTERIOR OF AUTOCOVER BOX TO BE FULLY TILED COMPOUND GAUGE SUCTION VALVE PRESSURE GAUGE DISCHARGE VALVE CHECK VALVE ANTI-VIBRATION FITTING 4" HOUSEKEEPING PAD 1/2" RUBBER PAD CONCENTRIC REDUCER ONLY WHEN REDUCING GROUND PUMP PER NEC 680 NOTE: REFER TO MANUFACTURERS INSTRUCTIONS FOR ADDITIONAL DETAILS & REQUIREMENTS FLOW FL O W 2" SENSOR WELL LOCATED AT VERY END OF AUTO COVER BOX SO NOT TO INTERFERE WITH COVER INSTALLATION SENSOR CABLE WATER LEVEL SENSOR SECURELY INSTALLED @ IDEAL WATER LEVEL (-6" BELOW T.O. COPING) SOLENOID LOOP BACKFLOW PREVENTER BALL VALVES TO POOL CIRC LINE RE: PIPING SCHEMATIC FROM CITY SUPPLY 1" WATERTIGHT CONDUIT WATER LEVEL CONTROLLER SELECT POWER LEVEL SENSOR FILLING LOW WATER FILL TIMEALARM LOW WATERALARMSENSOR ALARMRESET ELC 800rElectronic Level Control AquatiControl.com AquatiControl Technolog Englewood, CO PENTAIR, 08417, 1.5" FLOOR INLET @ 18" BELOW WATER LEVEL IN SPA WALL POOL WALL, RE; WALL DETAILS & SECTIONS FOR DESIGN GASKET RING/ CORD SEAL WATERPROOFING BACK OF AUTO COVER BOX AUTOCOVER POOL WATER LEVEL SENSOR TO BE LOCATED IN POOL HOLDING TANK NOTE: DRAIN COVER & SUMP MUST BE VGB COMPLIANT. CONTRACTOR IS FULLY RESPONSIBLE TO CONFIRM ALL SUBMERGED SUCTIONS MEET OR EXCEED ANSI/APSP/ICC-7 2013 APSP-7/VGBA APPROVED "UNBLOCKABLE" CHANNEL DRAIN COVER & SUMP, FOR CONCRETE INSTALLATION. INSTALL PER MANUFACTURES INSTRUCTIONS CIRC. SUCTION PIPE GRAVEL BASE DRAIN FULLY ENCASED IN MIN. 8" CONCRETE RE: SLAB DETAIL FOR THICKNESS & REBAR DESIGN POOL FINISH SCALE: ISSUE DATE: DRAWN BY: PROJECT #: SHEET #: SHEET TITLE: DA T E TI T L E / P U R P O S E NO . 3. 2 2 . 2 0 2 2 10 0 % C D S E T 13301 W. 43rd Drive Suite #10 Golden, Colorado 80403 Phone: 720.693.8146 As indicated CPD 3/22/2022 1221 CONSTRUCTION DETAILS PL2.2 85 5 C h a t f i e d R o a d As p e n , C o l o r a d o 8 1 6 1 1 CH A T F I E L D V I E W S P A 3/4" = 1'-0"1 FRONT ACCESS SKIMMER DETAIL 3" = 1'-0"3 CIRC. INLET DETAIL NO SCALE4STRUCTURAL INSTALLATION NOTES NO SCALE5POOL SHELL PENETRATION REINF. NO SCALE6 POOL STRUCTURE CORNER MAT REINFORCING 3/4" = 1'-0"8 POOL AUTO COVER BOX DETAIL NO SCALE7POOL PUMP INSTALLATION 1" = 1'-0"9 SPA AUTO FILL DETAIL 1" = 1'-0"2 CHANNEL DRAIN DETAIL 48409 COL O R A D O L ICE N S E D P R O F E SSIONA L E N GINEER A DAM J . S HAUG H N E S S Y 3/22/2022 THESE DRAWINGS WERE NOT PRODUCED BY STRUCTURAL ENGINEERING SOLUTIONS, INC. BUT HAVE BEEN REVIEWED FOR STRUCTURAL ADEQUACY. THE P.E. STAMP PROVIDED HEREIN APPLIES ONLY TO THE STRUCTURAL ITEMS ON THIS SHEET. 08/05/2022