626 S. Galena St. Air Conditioning Unit As.en, CO S.ecifications M-SERIES SUBMITTAL DATA: MSZ-GL18NA U1 � MITSUBISHI 18,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS /`ELECTRIC Job Name: System Reference: Date: SPECIFICATIONS: Rated Capacity° Cooling' Btu/h/w 18,000 — - ' Heating at47°F2 Bu/h/W 21,600 \ — o0 Rating Conditions per AHRI Standard: 'Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB;Outdoor:95°F(35°C)DB/75°F(24°C)WB Indoor Unit:IVS7.GI18NAU1 °Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB;Outdoor:47°F(8°C)DB/43°F(6°C)WB For data on specific indoor units(all ducted,all non-ducted,and both ducted and non-ducted) combinations,see the MXZ Technical and Service Manual. Wireless Remote Controller Applications should be restricted to comfort cooling only;equipment cooling applications are not recommended for low ambient temperature conditions. Electrical Power 208/230V, 1-Phase,60 Hz ACCESSORIES: Requirements Indoor Unit Minimum Circuit A 1 o Condensate Pump(BlueDiamond X87-711/721;115/230V) Ampacity(MCA) ❑ Condensate Pump(Sauermann SI30-115/230;115/230V) ❑ Anti-Allergy Enzyme Filter(MAC-408FT-E) ❑ Platinum Catalyst Deodorizing Filter(MAC-308FT-E) Blower Motor(ECM) ELA 0.76 o Drain Pan Level Sensor(DPLS2) Blower Motor Output W 55 Controls o Wireless Controller(MHK1) Field Drainpipe Size O.D. In.(mm) 5/8(15) o Wireless Interface for kumo cloud TM(PAC-WHS01 WF-E) o Thermostat Interface(PAC-US444CN-1) Airflow Rate(Quiet-Lo-Med-Hi-Super Hi) DRY 259-333-416-523-646 Cooling WET CFM 233-300-375-470-581 Heating DRY 296-384-469-563-646 Sound Pressure Level(Quiet-Lo-Med-Hi-Super Hi) Cooling 28-33-38-44-49 dB(A) Heating 28-33-38-43-48 External Dimensions In( ) 12 x 36-5/16 x 9-13/16 mm (HxWxD) (305x923x250) Net Weight Ibs.(kg) 28(13) External Finish Munsell 1.0Y 9.2/0.2 Refrigerant Piping(Flared) Liquid(High Pressure) 1/4(6.35) In.(mm) Gas(Low Pressure) 1/2(12.7) RECEIVED Specifications are subject to change without notice. ©2016 Mitsub hi Elec-frlcZ.1S,nc. 21 1 of 8 ASPEN BUILDING DEPARTMENT 626 S. Galena St. Air Conditioning Unit Aspen, CO Specifications DIMENSIONS: Z-GL18NA U1 MSZ-GL18NA-U1 Unit:in.(mm) 7/16x13116 Installation plate Oblong hole Indoor unit 1x7/16 Oblong hole 3-11116 36-5/16 3-11/16 8-7/8 8-7/8 35-13/16 tiv 1/4>( R (i1IIi -'I v % / � w w /, co � 9-13/16 8-11/16 > 8-1/16 co 3/16 MI 2.5116 15-7/8 15-3/16 -c3 n I Air inWall hole 03 I� v Installation plate '-il� v v_ _I p 1 -4- 2-1/2 2-1/16 27-15/16 =6-5116 Pi in N 'I ,� o N / Drain hose 2-5/161 11 3/4 ` _,-*-,-*,-�-*-r !!i ^ 2-9/16 LN3) 4 i liiill_ � 4-1/2 H . Nrout 5-314 N 2-9/16 2-9/16 k� N N 3-11/16 > cr, Insulation 02 O.D .a Liquid line 05/16 15-3/8 (Flared connection 01/4) a Gas line 015/32 13-3/8(Flared connection 01/2) Drain hose Insulation 01-1/8 Connected part 05/8 O.D MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA30024 Toll Free:800-433-4822 wwwmAIED ehvac.com AVw�CERTIFIED t FORM#MSZ-GL18NA-U1 FOR MXZ-C MULTI-ZONE SYSTEMS-201608 u.,`""^-"-^--"`""^^^^""—^^ Intertekek Specifications are subject to change without notice. ©2016 Mitslili'E/lectn`c US2nc0 21 2 of 8 ASPEN BUILDING DEPARTMENT 626 S. Galena St. Air Conditioning Unit As.en, CO S.ecifications M-SERIES SUBMTTAL DATA M�3 C30NA2 � MITSUBISHI MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM M ELECTRIC Job Name: System Reference: Date: 1.- 11 11 11 Outdoor Unit:I XZ-3C30NA2 ACCESSORIES o 3/8"x 1/2"Port Adapter(MAC-A454JP-E) o 1/2"x 3/8"Port Adapter(MAC-A455JP-E) o 1/2"x 5/8"Port Adapter(MAC-A456JP-E) o 1/4"x 3/8"Port Adapter(PAC-493PI) o 3/8"x 5/8"Port Adapter(PAC-SG76RJ-E) o M-NET Adapter(PAC-IF01MNT-E) o Base Heater(PAC-645BH-E) (For data on specific indoor units,see the MXZ-C Technical and Service Manual.) Specifications Model Name Unit Type MXZ-3C30NA2 Rated Capacity Btu/h 28,400/27,400 Cooling* Capacity Range Btu/h 12,600-28,400/12,600-27,400 (Non-ducted/Ducted) Rated Total Input W 2,680/2,860 Rated Capacity Btu/h 28,600/27,600 Heating at 47°F* Capacity Range Btu/h 11,400-36,000/11,400-35,000 (Non-ducted/Ducted) Rated Total Input W 2,150/2,220 Heating at 17°F* Rated Capacity Btu/h 16,000/15,100 (Non-ducted/Ducted) Rated Total Input W 2,120/2,140 Power Supply Voltage,Phase,Hertz 208/230V,1-Phase,60 Hz Electrical Requirements Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor-Outdoor S1-S2 V AC 208/230 Indoor-Outdoor S2-S3 V DC±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor(ECM) F.L.A. 2.43 52 Sound Pressure Level Heating Cooling dB(A) 56 External Dimensions(H x W x D) In(mm) 31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs(kg) 137(62) External Finish _ Munsell 3.0Y 7.8/1.1_ Refrigerant Pipe Size O.D.— Liquid(High Pressure) In(mm) 1/4(12.7) Eight Ports Gas(Low Pressure) A:1/2(6.35);B,C:3/8(9.52) Max.Refrigerant Line Length Ft(m) 230(70) Max.Piping Length for Each Indoor Unit Ft(m) 82(25) Max.Refrigerant Pipe Height If IDU is Above ODU 49(15) Difference If IDU is Below ODU Ft(m) 49(15) Connection Method Flared/Flared Refrigerant I R410A *Rating Conditions per AHRI Standard: Cooling I Indoor:80°F(27°C)DB/67°F(19°C)WB Heating at 47°F I Indoor:70°F(21°C)DB/60°F(16°C)WB Heating at 17°F I Indoor:70°F(21°C)DB —s Cooling I Outdoor:95°F(35°C)DB/23.9°C(75°F)WB Heating at 47°F I Outdoor:47°F(8°C)DB/43°F(6°C)W B Heating at 17°F I Outdoor:17°F(-8°C)DB/15° 1 Specifications are subject to change without notice. ©2016 Mitsub hi Elec-fricZ.1S, nc021 3 of 8 ASPEN BUILDING DEPARTMENT 626 S. Galena St. Air Conditioning Unit Aspen, CO Specifications SPECIFICATIONS: MXZ-3C30NA2, contd. OPERATING RANGE: ENERGY EFFICIENCIES: Outdoor Indoor Unit Type SEER EER HSPF COP @ COP 47°F @ 17°F Cooling 14 to 115°F(-10 to 46°C)DB Non-ducted Heating 5 to 65°F(-15 to 18°C)WB (06+06+09) 19.0 10.6 10.6 3.90 2.77 Ducted and 17.6 10.1 10.1 3.77 2.78 Non-ducted Ducted 16.2 9.6 9.6 3.64 2.78 (09+09+09) NOTES: • Minimum of two Indoor Units must be connected to the MXZ-3C30NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130%of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: -MXZ-C Technical&Service Manual for detailed specifications and additional information per Indoor Unit Combination. -MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. MVZ CONNECTION RULES: • Only 1 MVZ may be used on any system. • When an MVZ is connected,total connected capacity must be 100%or less. • When an MVZ is connected,no P-Series indoor units can be used(PCA,PLA,or PEAD). Notes: RECEIVED Specifications are subject to change without notice. ©2016 Mitsui h E1c,/u iPc2 1 4of8 ASPEN BUILDING DEPARTMENT 626 S. Galena St. Air Conditioning Unit Aspen, CO Specifications MXZ 3C3ONA2 OPERATIONAL PERFORMANCE DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor Heating Capacity Range(Btu/h) Power Usage Range Current(208/230V) Unit Combinations (W) (Unit A+Unit B+Unit C) UnitA Unit B Unit C 9 9000 0 0 10900 0 0 12 12000 0 0 13600 0 0 15 15000 0 0 18000 0 0 18 17200 0 0 21600 0 0 24 24000 0 0 26000 0 0 9+9 9000 9000 0 10900 10900 0 9+12 9000 12000 0 10500 14000 0 9+15 9000 15000 0 10200 17000 0 g+18 8733 17467 0 9133 18267 0 9+24 7418 19782 0 7473 19927 0 12+12 12000 12000 0 — 13600 13600 0 12+15 11644 14556 0 12178 15222 0 TBD 12+18 10880 16320 0 10960 16440 0 12+24 9067 18133 0 9133 18267 0 15+15 13600 13600 0 13700 13700 0 15+18 12364 14836 0 12455 14945 0 18+18 13600 13600 0 13700 13700 0 g+g+g 9000 9000 9000 9133 9133 9133 9+9+12 8220 8220 10960 8280 8280 11040 g+g+15 7582 7582 12636 7582 7582 12636 9+9+18 7050 7050 14100 7000 7000 14000 9+12+12 7582 10109 10109 7582 10109 10109 9+12+15 7050 9400 11750 7000 9333 11667 12+12+12 9400 9400 9400 9333 9333 9333 RECEIVED Specifications are subject to change without notice. ©2016 Mitslisni'E1ec5 USinc.c 21 5 of 8 ASPEN BUILDING DEPARTMENT 626 S. Galena St. Air Conditioning Unit Aspen, CO Specifications MXZ-3C30NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Cooling Capacity Range(Btu/h) Performance for Indoor Heating Capacity Range(Btu/h) Power Usage Range Current(208/230V) Unit Combinations (W) (Unit A+Unit B+Unit C) Unit A Unit B Unit C 6 6000 0 0 7400 0 0 9 9000 0 0 11000 0 0 12 12000 0 0 14400 0 0 15 14000 0 0 18000 0 _ 0 18 17200 0 0 21600 0 0 24 22500 0 0 27600 0 0 6+6 6000 6000 0 7400 7400 0 6+9 6000 9000 0 7360 11040 0 6+12 6000 12000 0 7333 14667 0 6+ 15 5714 14286 0 7257 18143 0 6+18 5750 17250 0 — 6900 20700 0 6+24 5440 21760 0 5520 22080 0 9+9 9000 9000 0 11000 11000 0 9+ 12 8571 11429 0 10886 14514 0 9+15 8625 14375 0 10350 17250 0 TBD 9+18 8600 17200 0 9200 18400 0 9+24 7418 19782 0 7527 20073 0 12+12 11500 11500 0 13800 13800 0 12+15 11467 14333 0 12267 15333 0 12+18 10880 16320 0 11040 16560 0 12+24 9067 18133 0 9200 18400 0 15+15 13600 13600 0 13800 13800 0 15+18 12364 14836 0 12545 15055 0 18+18 13600 13600 0 13800 13800 0 6+6+6 6000 6000 6000 7400 7400 7400 6+6+9 6000 6000 9000 7371 7371 11057 6+6+12 6000 6000 12000 7100 7100 14200 6+6+15 5778 5778 - 14444 6311 6311 15778 6+6+18 5680 5680 17040 5720 5720 17160 6+6+24 5000 5000 20000 5000 5000 20000 RECEIVED Specifications are subject to change without notice. ©2016 Mitslisni'Elec5 US29 21 6 of 8 ASPEN BUILDING DEPARTMENT 626 S. Galena St. Air Conditioning Unit Aspen, CO Specifications MXZ-3C30NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: Operational Coding Capacity Range(Btu/h) Performance for Indoor Heating Capacity Range(Btu/h) Power Usage Range Current(208/230V) Unit Combinations (W) (Unit A+Unit B+Unit C) Unit A Unit B Unit C 6+9+9 6000 9000 9000 7100 10650 10650 6+9+12 5778 8667 11556 6311 9467 12622 6+9+15 5680 8520 14200 5720 8580 I 14300 6+9+18 5382 8073 16145 5382 8073 16145 6+12+12 5680 11360 I 11360 5720 11440 11440 6+12+15 5382 10764 13455 5382 10764 I 13455 6+12+18 5000 10000 15000 5000 10000 15000 6+15+15 5000 12500 12500 TBD 5000 12500 12500 g+g+9 8667 8667 8667 9467 9467 9467 9+9+ 12 8520 8520 11360 8580 8580 11440 g+g+15 8073 8073 13455 — 8073 8073 13455 9+9+18 7500 7500 15000 7500 7500 15000 9+12+12 8073 10764 10764 8073 10764 10764 9+12+15 7500 10000 12500 7500 10000 12500 12+ 12+12 10000 10000 10000 10000 10000 10000 RECEIVED Specifications are subject to change without notice. ©2016 Mitslisni'Elec5 US29 21 7 of 8 ASPEN BUILDING DEPARTMENT 626 S. Galena St. Air Conditioning Unit Aspen, CO Specifications DIMENSIONS: MXZ 3C30NA2 Unit: inch (mm) 6-7/8' 23-5/8' .-7/8' Rear Air 111 Intake 2-13/16' 1/16' 4-19/32' 2-1/32' 2-U Shaped Notched Hole 13/32' SE. N (Foundation Bolt M10) ZN Sltle Air Intake b A_ o p m a IU Av ry 113/32' 6-01-5/16•Droin Hole Otcharge 13/32' 19. 2-(15/32'X1-13/32')Oval Hole 1-1/32' 2-07/8'knackout hole (Foundotlon Bolt M10) 1-1/2' I (Connectin•wne hoLe) 1 5/8" 37 13/32 31/32' 13' 19/32' 3-07/8'punehed hole I (Connect'ng wire hole) Handle _ ��� I Handle 1{ 1 j1 p�1 H Ifillloli1lllll a tlle III q 2-3/4II illIP I IllllllllIIPIill gllllllllllllll l' • Rl���il Air Intake f j® 11llllllllllllll'llp�l��lpllllllllllll!II l -- Ill (III .' LIO l Unit C 1I} 1 j® EllllilllillllllllllllllllllIIIII IIIIIIIIIIPI'Idl 111�11 Gm J Unit816A5 3/BY0952lFLARE e .__, _ Mil ( llllllll�l���l�llllll II�IIA }ui.11l 1® lull 11� 1LIOwolf A- LIO 1/L'106.35)FLARE It 6@' 'r�'-11 GAS GAS 1/21012.1iFLARE 41 I1-11/32' 14-7/32' .. 1.FREE SPACE E O 3-15/16' or more p o 0 3-15/16' or13-25/32'or more sii/'1 Conduit plates more ifinifOR iv Conduit connector 2.SERVICE SPACE / .:I . I. Lock nut 3-15/16'or more SERVICE SPACE 13-25/32"or more 13-25/32' or more MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard.Suwanee,GA30024 Toll Free:800-433-4822 wwwmehvac.com ti /CERTIFIED-. Ltazgo, w E . ED FORM#MXZ-3C30NA2 for Multiple Indoor Unit Styles-201608Ver2 ``-ten•""""'-•`""`•`"".-."- l l interte/k Specifications are subject to change without notice. ©2016 Mits ibti Ee n5U?Pic?1 8of8 ASPEN BUILDING DEPARTMENT