HomeMy WebLinkAboutFile Documents.626 S Galena St.0140-2021-BRES (15) F I_ AR E SPEC SHEET : RD-80
‘FIREPLACES
DIRECT VENT FLARE RD-80
FLARE FRAMELESS MODERN ROOM DEFINER FIREPLACE
(SS)Safety Screen/(DG) Double Glass
SUBJECT DETAILS
Gas Type Natural Gas (NG) or Liquid Propane (LP)
Safety Standard CSA File#263124-ANSI Z21.88-CSA 2.33
Operation Mertix GV60 Honeywell SIT
Electrical Requirements 110 Volts, 15 Amps (DEDICATED POWER RECOMMENDED)
Glass Height 16"
Optional RGB LED
Optional Multi-Colored Interior RGB LED Lighting System
System
Optional Power Vent End-Of-Line
System End-Of-Line Vertical Horizontal Inline
Optional Double Glass Optional Cooler Touch Double Glass
IN CRATE NO CRATE
Weight
507 (SS)/556 lbs (DG) 406 (SS)/443 lbs (DG)
Cool Wall Tech Allows for TV or art above your Flare
Burners Multi-Row Stainless Steel Burner
FIRE GLASS 1/2" & 1/4" CERAMIC LOGS EMBERS
Interior Media Options FIRE BEADS CERAMIC CERAMIC STONES
BRANCHES
ZIRCON DIAMONDS CERAMIC CERAMIC STONE BALLS
BIRCHWOOD
Product Specifications
• The Flare Fireplace is certified for use with either Natural Gas (NG) or Propane (LP)
• The Flare Fireplace operates with a direct vent, balanced flue system.A direct vent gas fireplace is room-sealed using
ceramic glass.
• The Flare Fireplace use's double pipe vent flue to pull in fresh air from outside& release exhaust gases to the outside.
Clearances to combustible materials MUST be maintained. Refer to Installation Manual for clearance distances.
• The Flare Fireplace must be properly connected to a venting system. RECEIVED
• The Flare Fireplace must be installed according to requirements as presented in the Installation Manual, as well as
complying with all local codes. If no codes exist,then the current CSA installation code must be followap2/19/2022
ASPEN
BUILDING DEPARTMENT
F I_ AR E SPEC SHEET : RD-80
‘FIREPLACES
Parts Included: Optional Features &Accessories:
• Flare Fireplace • Reflective Black Ceramic Back
• Ceramic Glass Panel(s) • Summer Kit Heat Control System
• Invisible Mesh Safety Screen • Home Automation Integration (3rd
• Option of "Classic" Media Party Support Only)
• Complete Electronic ignition Pilot • Battery Backup (Screen Units Only)
Assembly
• Spare Parts Kit Approved Venting Specification:
• Adjustable Telescopic Legs & Mounting • DuraVent
Brackets • ICC
• AC Power Supply, Remote Control, & • Natural Draft Pipe Size: 5x8
Wall Switch • Power Vented Pipe Size: 3x5
Gas Pressure& Power Output
GV-60
GAS INLET PRESSURE MANIFOLD MAX BTU ORIFICE SIZE BURNER SIZE(inches)
MIN. MAX. PRESSURE INPUT Burner 1 Burner 2 Burner 3 Burner 1 Burner 2 Burner 3
NG 7.0"WC 8.0"WC 3.09 55,700 480 1200 480
LP 10.0"WC 11.0"WC 6.38 46,000 160 380 160 14 40 14
SIT
GAS INLET PRESSURE MANIFOLD MAX BTU ORIFICE SIZE BURNER SIZE(inches)
MIN. MAX. PRESSURE INPUT Burner 1 Burner 2 Burner 3 Burner 1 Burner 2 Burner 3
NG 7.2 "WC 8.2"WC 3.5 55,000 420 1000 420
LP 10.0"WC 11.0"WC 9.5 49,000 140 320 140 14 40 14
HONEYWELL
GAS INLET PRESSURE MANIFOLD MAX BTU ORIFICE SIZE BURNER SIZE(inches)
—
MIN. MAX. PRESSURE INPUT Burner 1 Burner 2 Burner 3 Burner 1 Burner 2 Burner 3
NG 7.0"WC 8.0"WC 2.61 55,700 480 1200 480
LP 10.0"WC 11.0"WC 5.46 46,000 160 380 160 14 40 14
For more information on Flare or our amazing features please visit: https://www.flarefireplaces.com
RECEIVED
12/19/2022
ASPEN