Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.1039 E Cooper Ave.0127-2020-BRES (15)
GENERAL NOTE: FLOOR AND COMMON PARTITION WALLS TO MAINTAIN THE CURRENT STC RATING OR BETTER ri• I INTERIOR I 'INTERIOR I I INTERIOR I I INTERIOR I rowl a n d+b ro u g hto n architecture/urban design/interior design 1 1/2" 500 w.main st. 1830 blake st. X aspen,co 81611 denser,co 80202 970.544.9006 303.308.1373 ���I I FINISH,RE:FINISH SCHEDULE �%1% II Consultants: �/ I GYP BD,5/8" 1 I I WOOD PANELING ��, i I BATT INSULATION i PLYWOOD SHEATHING I'A' 2X WD FRAMING 11N 2X WD FRAMING 1 I� I �1 I GYP BD,5/S" Ln,���i1 GYP BD,1/2" I ' l' �010 FINISH,RE:FINISH SCHEDULE 111 FINISH,RE:FINISH SCHEDULE II /I r iiIH I %1% 1 hIII i.. Issuances and Revisions: 0A 2020-10-26 11 B 2020-12-17 PRICING SET ION DOCUMENTS ��;� I.. C 2021-01-08 CONSTRUCTION DOCUMENTS AMENDMENT 1 D 2021-02-11 CONSTRUCTION DOCUMENTS AMENDMENT 2 W 1 INTERIOR WALL ASSEMBLY IW2 INTERIOR MILLWORK WALL ASSEMBLY A6.1 SCALE: 3"=1'-0" A6.1 SCALE: 3"=1'-0" IEXTERIORI W U EXISTING ROOF/CEILING w N ASSEMBLY. y EXISTING ROOF ASSEMBLY. w NO PROPOSED CHANGES TO 4 NO PROPOSED CHANGES TO STRUCTURE/RATED ASSEMBLY Cr STRUCTURE/RATED ASSEMBLY , O F____D, I sl f u f GYP BD,5/8" IY / _ � RECESSED LIGHT-IC RATED �0 , _ ? w ,- , BATH EXHAUST FAN WITH FIRE i� �- 1 DAMPER i --- GYP BD,5/8" U j . o RE:RCP FOR LOCATION St 3-5/8"CFS FRAMING iii -__Z- GYP BD,5/8" SUSPENDED CEILING SYSTEM FOR CITY OF ASPEN FINISH,RE:FINISH SCHEDULE FINISH,RE:FINISH SCHEDULE RECESSED LIGHT-IC RATED EXISTING BEAM BEYOND RE:RCP FOR LOCATION I INTERIOR I All GYP BD,5/8" P�OF CO(09 I INTERIOR I /yti 9O SARA., , IB B . •,r 5 ti CEILING ASSEMBLY- �' �,� illi CEILING ASSEMBLY C2 TYP.SUSPENDED CEILING y`r-D pR�a\ ® SCALE: 3"=1'-0" ® SCALE: 3"=1,-0„ RECEIVED 03/15/2021 BALDWIN IUI I ASPEN BUILDING DEPARTMENT OFIREPLACE HEARTH _ 1039 E COOPER AVE, UNIT 30A ASPEN,CO 81611 11 EXISTING FIREPLACE TO BE RECLAD METAL TRIM AT EXISTING OPENING �111 METAL CORNER TRIM ® I PROJECT NO: © 22025.00 —— I THIN SET STONE AND MORTAR ■1r rll - SHEET TITLE: EXISTING FIREPLACE. � EXISTING CLADDING TO BE REMOVED. iji i SHEETDETAILS/ FIREPLACE 03/15/2021 J FDRGCMCOMPLIAl117E SCALE:As indicated denism i A6. 1 PLAN TRUE NORTH NORTH I° 7. 1 ENLARGED FIREPLACE PLAN j\ � 2 FIREPLACE ELEVATION 3 DTL-FIREPLACE CORNER TMEaE," S A6.1 SCALE: 1/2"=1'-0" l ` .® SCALE: 1/2"=1'-0" A6.1 SCALE: 11/2"=1'-0" COMMON LAVYSTATUTORIANDOTIEPRESERVEDPIGKS,„C,,a„GCo„p,GI„ €'s