HomeMy WebLinkAboutFile Documents.13 E Water Pl.0008-2023-BREP (10) I--I P
Hepworth-Pawlak Geotechnical,Inc.
5020 County Road 154
Ge .)tecl-"i Glenwood Springs,Colorado 81601
Phone:970-945-7988
HEPWORTH-PAWLAK GEOTECHNICAL Fax:970-945-8454
email:hpgeo@hpgeotech.com
Revised March 23, 2010
March 10, 2010
City of Aspen
Attn: Larry Doble
<Larry.Doble@ci.aspen.co.us
Job No. 110 030A
Subject: Slope Stability Analysis, Steep Slope Between Castle Creek Road and
Water Place Housing, Aspen, Colorado
Dear Larry:
As requested, we observed the subject slope and performed stability analysis at the
subject site to evaluate the existing slope conditions and possible mitigation methods.
The findings of our analysis and preliminary recommendations for the mitigation design
are presented in this report. The services were performed in accordance with our
agreement for professional engineering services to the City of Aspen, dated February 4,
2010. We previously conducted a subsoil study for design of foundations at Water Place
Housing and presented our findings in a report dated May 8, 1995, Job No. 195 192.
Slope Conditions: We observed the slope conditions on February 23, 2010. Overall, the
slope faces east and is up to 90 feet high above Castle Creek Road. The slope has been
over steepened by Castle Creek Road construction. No attempt to mitigate the steep slope
has been performed resulting in a large escarpment which appears to be actively raveling
down into Castle Creek Road. Jersey barriers have been placed on the uphill side of the
road to catch rocks falling from the slope. The snow directly behind the Jersey barriers is
about 3 feet deep. The lower two thirds of the escarpment slope is snow covered and very
steep, estimated at about 45 to 50 degrees from horizontal. The upper third is clear of
snow and near vertical, estimated at an average of 70 degrees with some areas that are
steeper. The soils exposed in the snow clear, near vertical slope appeared to be glacial
moraine deposits consisting of relatively dense, silty sandy gravel with cobbles and
boulders. The top of the slope,just below Water Place Housing, is snow covered,
vegetated with oak brush and slopes at 30 to 45 degrees. No water seepage from the slope
was observed.
Slope Stability Analysis: We analyzed the highest part of the slope which is directly
below the portion of Water Place Housing closest to Castle Creek Road. The slope profile
was taken from the aerial photograph with topographic lines that was provided to us. The
stability of the existing natural slope was evaluated by a two-dimensional limiting
equilibrium method computer program(SLOPE/W—Version 5) which calculates the
factor of safety against instability by the Janbu simplified method of slices. We assumed
that the soils in the slope consist of relatively dense sand and gravel with cobbles and
Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthome 970-468-1989
City of Aspen
March 10, 2010
Page 2
boulders. Based on the slope of the lower escarpment and our experience with similar
soils, we estimated that the angle of repose is similar to the slope indicating a strength
angle of 50 degrees with an assumed moist unit weight of 135 pcf. The groundwater level
was assumed to be about 7 feet below the ground surface in the middle of the Water Place
Housing (based on our previous study) and linearly down to the ground surface at the toe
of the slope next to Castle Creek Road.
Analyzing the near vertical portion of the slope and assuming a factor of safety of 1.0 for
that part of the slope results in an "apparent cohesion"value of 175 psf. The"apparent
cohesion" may be caused by temporary, light cementing of the soil. Based on that
cohesion value and a 50 degree strength angle, we analyzed the overall slope, which
results in a calculated factor of safety of 1.0 for a slip surface that extends back to the
eastern foundation walls of the nearest buildings. Subsequently, we analyzed two
potential mitigation techniques which consisted of two rows of tiebacks placed just above
Castle Creek Road or a 17 foot high mechanically stabilized earth (MSE) retaining wall
• placed on the uphill side of Castle Creek Road.
Discussion: Typically, factors of safety greater than 1.5 are considered adequate for slope
stability. Factors of safety between 1.5 and 1.0 are considered temporarily stable but
could become unstable due to erosion, rising groundwater table, additional loading or
vibration from seismic events. Factors of safety below 1.0 indicate a high risk of potential
failure. The actual values calculated in our analysis are based on assumptions including
soil strength and location of water table averaged over the slope. We intended that these
values be on the conservative side (resulting in lower factors of safety) while remaining
reasonable for the observed conditions. The purpose of our mitigation analysis was to
evaluate the potential increase in stability for the trial mitigation method.
While the slope has probably been eroding since Castle Creek Road was built and
probably widened, we expect it has been more or less stable with regard to massive slope
failure for many years including some very wet periods and many freeze/thaw cycles.
Eventually, the slope will continue to erode back to somewhere between 45 and 50
degrees, similar to natural slopes in the area. That slope will extend back into the eastern
foundation elements of the easternmost Water Place Housing buildings. The most likely
part of the slope for massive failure is the near vertical portion near the middle of the
overall slope which is probably the most difficult part of the slope to access. In order to
mitigate long-term progressive erosion of the slope which could potentially impact the
nearest Water Place housing units, we analyzed two mitigation methods (retaining wall
and tiebacks) Iocated at the bottom of the slope adjacent to Castle Creek Road which we
considered relatively accessible. These two methods provide increased factor of safety for
the overall slope (1.1 for the retaining wall and 1.3 for the tiebacks) but do nothing for the
stability of the higher, steeper portions which are the most likely to fail. The third option
is a micropile wall placed adjacent to Water Place Housing and constructed on that
property. This option does nothing to improve the slope condition but does protect Water
Job No. 110 030A
Ptech
City of Aspen
March 10, 2010
Page 3
Place Housing in the event of massive slope failure or the progressive eroding of the
slope. All three options would require a design/build specialty contractor.
Retaining Wall: Placing a 17 foot tall MSE wall along Castle Creek Road would buttress
the lower part of the slope and would provide a"landing area" for rockfall and a possible
working platform off Castle Creek Road for continuing mitigation of the upper slopes.
The increase in overall slope stability would only be about 10%. Placing a 1:1 reinforced
fill slope above the retaining wall would increase the factor of safety against overall slope
failure by about 20%but also greatly reduce the erosion potential. Construction would
involve the County and would be disruptive to traffic on Castle Creek Road.
Tiebacks: Placing two rows of 100 kip capacity tiebacks on 5 foot spacing at 5 and 10
feet above Castle Creek Road would result in an increase in stability of about 30% for
overall slope failure but would do nothing for slope failures in the upper, near vertical
portion of the slope. Placing 2 or 3 rows of tiebacks in the near vertical portion of the
slope would greatly increase the stability of that area but would be difficult to construct if
not impractical. Construction of some form of tiebacks would also involve the County
and be disruptive to traffic on Castle Creek Road.
Micropile Retaining Wall: It may be possible to construct a micropile retaining wall on
Water Place Housing property just downslope of the two buildings closest to the slope
which are about 20 feet off the property line. The wall would need to be about 80 feet
long and would consist of a series of vertical and battered micropiles connected at the top
with a concrete cap beam. We expect that the micropiles would be at least 40 to 50 feet
deep. The wall would be buried completely and designed to be self supported in the event
of progressive slope movement towards the buildings. This option would not involve the
County or disrupt traffic on Castle Creek Road. There would likely be some
inconvenience during construction to the residents of Water Place Housing.
Additional subsurface information and further evaluation of a selected option or options
should be obtained for design purposes.
The recommendations submitted in this letter are based on our observation of the
conditions exposed at the time of our site visit and the previous limited subsurface
exploration at the Water Place Housing site. Variations in the subsurface conditions
could increase the risk of slope movement. We should be advised of any variations
encountered in the slope conditions for possible changes to recommendations contained
in this letter.
Job No. 110 030A
COtech
City of Aspen
March 10, 2010
Page 4
If you have any questions or need further assistance, please call our office.
Sincerely,
HEPWORTH - PAWLI .PTCHNICAL, INC.
get E
Daniel E. Hardit P E 24443 s
t ter.
Reviewed by: SL o,� •, °•'�'�ti
DEH/kac
Job No. 110 030A
G Etech