HomeMy WebLinkAboutFile Documents.1010 E Hyman Ave.0008-2022-BROF (6) ECO CHIEF
CIO
•
r � 1�="/t" -y�
1 41.
411,
- A
4THE ENERGY SAVING
UNDERLAYMENT
SOLAR HIDE
AN ENERGY SAVING ADDITION FOR ANY ROOF
SYSTEM, INCLUDING ASPHALT SHINGLES
ATTIC TEMPS UP TO 30° COOLER WHEN PROPERLY
INSTALLED AS A RADIANT BARRIER
DURABLE & SLIP RESISTENT, EXCEEDS MIAMI
DADE SPECIFICATIONS
SYNTHETIC & 100% RECYCLABLE
10 SQ. ROLL (48" X 250')
`s' EripiFIVED
icc - 03/22/2022
888.733.2640 ( QRI'.
www.EcoChiefProducts.com ESR oas Yin.
BUILDING DEPARTMENT
• •
SAVES ENERGY!
SOLARHIDE .0 •
all
SOLARHIDE-SRW is a durable and energy
saving one-step radiant barrier roofing
underlayment. SOLARHIDE-SRW can
significantly increase energy savings and
overall energy efficiency of a structure. The
unique design of SOLARHIDE-SRW allows it SOLARHIDE-SRW ALSO
to reflect up to 97% of the radiant heat it MEETS CLASS A FIRE
encounters. When installed with the REQUIREMENTS WITH ANY
reflective surface facing an air space in the OF THESE ROOF COVERINGS:
roof system, SOLARHIDE-SRW acts as a
radiant barrier dramatically reducing radiant c.._�__
heat transfer. Roof assemblies installed fe" _.� =
with batten systems are excellent zwir r�
applications for the use of SOLARHIDE-SRW
_,____I,
-
underlayment. SOLARHIDE-SRW has also f --_ —
been proven effective at reducing heat
transfer under asphalt shingles. (Although Asphalt Shingles Slate
effective, this application cannot be ,‘11,�
classified as a "radiant barrier"). %101111114
0111''
40"._
SOLARHIDE-SRW can be used with most any
steep slope roofing assembly: Metal, Wood,
%Oh Pk,
Slate, Clay Tile, Stone Coated Steel,
Concrete Tile, and Asphalt Shingles. Concrete Tile Clay Tile
SOLARHIDE-SRW is a vapor barrier and
should always be installed on roof systems
with adequate ventilation.
Rip Installs Synthetic
Resistant Quickly & Recyclable
Synthetic Slate Synthetic Shake
- --'N — _ _ ----z-.-- _ L__------ ___-----
41,17.
iiiim ___ .--:- 1
____ _. 0 ra '___ _. __
iii
:, 20
-- �- -- — -- — — '- :1Uu11hid11,...
__,..
SOLARHIDE
SOLARHIDE-SRW
roof underlayment, 1
t\ roof deck
so, \ \\, \
w.. t
metal dApedge ,,, \ OLARHIOE' � \
on toe°f \1` 5
sOLARHIDE _
\ :-------
.y13e6,P"ei.......o+f•\ 4"Inc)
\ (side 1il1'
o \\
tt\
—
6"inch
(end laps)
'When used with batten roof systems.SOLARHIDE should be installed shiny side up.
SOLARHIDE performs best with the shiny side facing an air space.
CAUTION - Always follow OSHA safe roofing codes & practices when
installing any roofing product. Workers should always use and wear fall
protection devices when working on a roof. Proper high traction footwear,
toe boards, ropes and harnesses should always be a part of your safety
measures. Use extra caution on SOLARHIDE-SRW if it becomes wet or
dusty, as this may reduce traction. Serious injury or death can occur if you
fail to use proper safety gear and footwear.
/\ICC Chan A Fire Wing
......1EM MIAMI-DADE COUNTY 7�2 0 2 2
APPROVED
10
ESR-4035 u>sDoflzams4 1 SOU4IIDE FbnOa Pro..I Auu"r+N'F31931) PA
-
USE SOLARHIDE FOR A COOLER ROOF SYSTEM!
+ j
JUMP
� �!
likshib,
SOLARHIDE
INSTALL INSTRUCTIONS
Safety First! Always use on OSHA approved fall protection system, and carefully observe safe roofing codes
and practices. OSHA 1926.502
I MAKE SURE YOUR ROOF DECK IS CLEAN AND DRY. REMOVE ANY DEBRIS OR FASTENERS THAT MAY BE
PROTRUDING FROM THE ROOF DECK.
2.SOLARHIDE-SRW SHOULD BE INSTALLED HORIZONTALLY(PARALLEL)TO THE EAVE OF THE ROOF. INSTALL
SOLARHIDE-SRW WITH 4'INCH HORIZONTAL OR SIDE LAPS,AND 6"INCH VERTICAL OR END LAPS, FOR LOW
SLOPE ROOFS WITH A PITCH LESS THAN 4:12.OVERLAP SOLARHIDE-SRW AT LEAST 24"INCHES HORIZONTALLY
OVER THE UNDERLYING COURSE AND INCREASE END LAPS TO 8"INCHES.
3.ALWAYS USE CORROSION RESISTANT PLASTIC CAP NAILS,PLASTIC CAP STAPLES,OR TIN CAP NAILS.WITH AT
LEAST 1'INCH DIAMETER PLASTIC/METAL HEAD TO ATTACH SOLARHIDE-SRW TO THE ROOF DECK. FASTENERS
SHOULD PENETRATE THE ROOF DECK TO A MINIMUM DEPTH OF 3/4"INCH. FASTEN THE HORIZONTAL AND END
LAPS EVERY 6"INCHES AT CENTER ALONG THE CENTER OF THE ROLL IN THE FIELD. ALL FASTENERS MUST BE AT
90 DEGREES TO THE ROOF DECK AND DRIVEN FLUSH WITH SOLARHIDE-SRW
4.IF THE ROOF SYSTEM REQUIRES THE USE OF SEALANTS ON THE SEAMS AND JOINTS.USE A HIGH QUALITY.
LOW SOLVENT,PLASTIC ROOFING CEMENT.MEETING ASTM D-4586 TYPE 1 REQUIREMENTS. ALWAYS CONSULT
THE MANUFACTURER'S APPLICATION INSTRUCTIONS.
5.SOLARHIDE-SRW SHOULD BE COVERED WITH THE FINAL ROOFING MATERIALS WITHIN 180 DAYS OF BEING
INSTALLED.
SOLARWIDE--SAW is one component of a high quality roof system. Always make sure your roof system has
proper ventilation, and be sure to check and follow all applicable building ede nir
SOLRRHfDE-SRW meets or exceeds requirements for RSTM D-226 Type / d�
LA
03/22/2022
888.733.2640
www.EcoChiefProducts.com ASPEN
BUILDING DEPARTMENT