HomeMy WebLinkAboutFile Documents.215 N Garmisch St.0019-2023-BREP (6) City of Aspen
Commercial Projects
CREMP Calculation
Version 1.4(4/6/2023) Complete and submit this page for Commercial projects.
Project Address: 215 N Garmisch
Permit Number
Relevant Sheet Number(s): A1.3 and A1.4
List all drawing sheets containing REMP information.
Use this tab for Commercial projects(and Group R2&R3,4 stories or greater)or for commercial portions of mixed used buildings.
1.Enter all new exterior energy uses on the site
If existing energy uses are being replaced or relocated enter those uses in this tab as new and also enter them in the REMP-Existing tab under'existing to be
removed.'To receive credit for existing to be replaced or relocated energy uses,use the REMP-Existing tab.
Exempt energy uses:The following energy uses may be entered as'exempt'but you must demonstrate how this exemption is met(subject to approval by the I
In-Slab Snowmelt and Outdoor Electric Heat Mats:
1.A nine square foot portion of emergency escape and rescue window wells is exempt
2.Accessible routes as defined by IBC section 1104.1 and 1104.2 and limited to 48"in width is exempt
3.Sidewalks serving buildings or portions of buildings that are not residential buildings in the City Right of Way limited to 48"in width
Outdoor spa:
1.A maximum of(1)portable spa per property with a water surface area of not mom than 64 square
Heat tape including roof and gutter deicing systems and exterior piping:
1.Up to 1000 watts are exempt.
2.Enter all new interior fireplaces.
3.Use the appropriate tabs to enter renewable energy credits.Solar hot water system square footage is entered hem.
4.Energy offset amounts are totaled here,along with total credits.Credit received from existing to be removed or replaced systems as calculated in the REMP-Exis
tab is accounted for here.If you made a payment in lieu earlier in this project,enter that amount in"amont previously paid."
1.Exterior Energy Use Calculations
Offset required Exemption
Application EHcienc Full Offset kW %Offset - PV kW Payment in lieu
1.In-Slab Snowmelt 524 sq.ft. 96.0% I 15.60 i n/a
Calculated-Total area of proposed in-slab snowme0 and heat source efficiency. approved
(1 a)Exempt In-Slab Snowmelt: 524 sq.ft. 96.0% r 15.60 I n/a by B M
Enter area of exempt in-slab snowmen.COA to verify.
(lb)Non-Exempt In-Slab Snowmelt: 0 sq.ft. 96.0% I 0.00 100% P 0.00 $0.00 I
Enter total area of in-slab Snowmelt less the exempt area.
2.Outdoor Electric Heat Mats: I 0 I Watts I 100.0%I I 0.00 I n/a
Calculated-Total watts of proposed heat mats.
(5a)Exempt Heat Mats: 0 Watts I 100.0%I I 0.00 I n/a
Enter watts of exempt electrical heat mats COA to verify.
(5b)Non-Exempt Heat Mats: 0 Watts I 100.0%I I 0.00 I 100% I 0.00 I $0.00 I
Enter total wattage of heat mats less the exempt wattage.
3.Outtloor Spa: I 0 I sq.ft. I 92.0% I I 0.00 I n/a
Calculated-Total area of proposed spa and heat source efficiency.
(2a)Exempt Spa: 0 sq.ft. 92.0% I 0.00 I n/a
Enter total area of exempt spa(64 sq.ft.max)COA to verify.
(2b)Non-Exempt Spa: 0 sq.ft. 96.0% I 0.00 I 100% I 0.00 I $0.00 I
Enter total area of spa less the exempt area.
4.Outdoor Pool: 0 sq.ft. 96.0% I 0.00 I 100% I 0.00 I $0.00 I
Enter total area of proposed pool.
5.Heat Tape: I 0 I Watts I 100.0%I I 0.00 1 n/a
Calculated-Total watts of proposed heat tape/trace.
(4a)Exempt Heat Tape: 0 Watts I 100.0%I I 0.00 I n/a
Enter watts of exempt electrical heat tape/trace(lkw max).
(4b)Non-Exempt Heat Tape: 0 Watts I 100.0%I I 0.00 I 100% 0.00 $0.00
Enter total wattage of heat tape/trace less the exempt wattage.
6.Outdoor Electric Heaters: 0 Watts I 100.0%I I 0.00 I 100% 0.00 $0.00
Enter watts of permanently installed electricaly powered exterior heaters.
7.Temporary Outdoor Electric Heaters: 0 Watts I 100.0%I I 0.00 I 100% 0.00 $0.00
Enter watts of electricaly powered exterior heaters.
For uses not exceeding 180 days
B.Outdoor Gas Fireplaces&Firepits: 0 Btu/hr C 0.00 100% I 0.00 $0.00
Enter total fireplace&firepft BTUs.
Exterior Energy CREMP Payment Total: I 0.00 $0.00
2.Interior Energy Use Calculations
Offset required
Application Full Offset kW %Offset PV kW Payment in lieu
1.Indoor Gas Fireplaces: 0 Btu/hr 0.00 100% 0.00 $0.00
Enter total fireplace BTUs.Direct vent-sealed combustion units only.
Use RREMP tab for fireplaces inside individual sleeping&dwelling units Interior Energy CREMP Payment Total: I 0.00 I $0.00 I
3.On-site Renewable Credits
Offset Applied
Supplemental Energy Sources(options for on-site offset of projected energy consumption) equiv PV kW I Credit applied
1.GSHP(Ground Source Heat Pump) Btu I 0 I I 0.00 I $0.00
From GSHP Btu capacity on GSHP tab.Complete and submit that sheet
2.ASHP(Air Source Heat Pump) Btu I 0 I 0.00 $0.00
From ASHP Btu capacity on ASHP tab.Complete and submit that sheet
3.SHW(Solar Hot Water) sq.ft. I 0 I 0.00 $0.00
Use installed panel area.
4.PV Its be installed on site) kW I 0.00 I I 0.00 I $0.00
From PV Generation tab.Complete and submit that sheet.
5.Alternative Renewable Energy Source 0.00 I $0.00
From Alt Energy Source tab.Complete and submit that sheet.
Supplemental Energy Credit Total: I 0.00 I 80.00
4.Total CREMP Payment:
PV kW Payment In lieu
Total Exterior and Interior Energy(Sections 1&2 above): 0.00 $0.00
Total On-site Mitigation(Section 2 above): 0.00 $0.00
Prorated Credit for"Existing to be Removed": $0.00
Amount previously paid on this project: $0.00
Prepared by: Barry Gereb Total CREMP Due: $0.00
email bany.gereb@bgadaspen.com
phone 9709486709
COA reviewer: Jim Pomeroy
ro' RECEIVED