Loading...
HomeMy WebLinkAboutFile Documents.5 E Water Pl.0059-2023-BROF (12) CITY OF ASPEN PERMIT NO.0059-2023-BROF _ �_ Snow stops required at all locations Field Plan Set Must Be Printed In Color ,`1 • where roofs could shed snow onto OWNER BARNETT FORREST S _ walkways,stairs,alleys,decks,exits, ACC �''',I �+ utilities and meters,emergency escape [� ADDRESS ` Existing downspout - • I and rescue opening window wells,or ES EVALUATION 5 E WATER PL to be replaced like ` -� adjacent properties-IBC 1513/COA 'ERVICE PARCEL IDfor like.Drains to 1ti s 8.20.020(z)._ _ _ CITY OF 273513204005O landscaping - - �� ASPEN Heat trace/tape must be self-regulating , type cable and must include automatic - • l .• lit e controls and timer capable of turning ,,lL c lance wits mterna0onal Codes APPLICATION ACCEPTED DATE: 12023-06-08 PERMIT NUMBER: 0059-2023-BROF r ` • it, 7a=`e a Extent of proposed off the system when the outdoor 0 '- • Compliance with State Codes These plans must De Kept at the i_a work • temperature is above 50 degrees and Or•• during daylight hours. building site or inspection COMMUNITY DEVELOPMENT DEPARTMENT a \ \ ♦ . P • www,icc-es.ora I (800)423-6587 I (562)699-0543 A Subsidiary of the International Code Council°' delays may occur.Construction 1 4,I r • A shall conform to these plans.All BUILDING PERMIT COVERSHEET All areas not called ►VI changes be approved by CITY OF ASPEN _ , ICC-ES Evaluation Report Reissued January 2023 the shallofficial. out as hardscape building are landscaping # 11)4, ' ESR-1389 This report is subject to renewal January 2024. PROPERTY INFORMATION �77 t •` - •i ADDRESS 5 E WATER PL UNIT. Hardscapepatio 10411"` SEPARATE PERMITS ARE P At" ( DIVISION:07 00 00—THERMAL AND MOISTURE with asphalt on both sides,and surfaced with mineral roofing PARCEL ID: 273513204005 LEGAL DESCRIPTION: WATER PLANT AFFORDABLE PROTECTION granules on the weather side and a mineral release agent REQUIRED FOR ELECTRICAL, ifou5ING PLUMBING,MECHANICAL,OR OWNER', BARNETTFORRESTS , 7• Section:07 31 13—Asphalt Shingles on the back side JJ FIRE SPRINKLER WORK PERMIT CONTRACTOR: CITY OF ASPEN-ASSET MANAGEMENT — 3.3 Laminated Shingles: Existing gutter to be AA-• , • REPORT HOLDER: replaced like for like . •, •►►- _ _ • ` • Laminated shingles, including two-layer laminated,three- SMOKE ALARMS AND ik • CERTAINTEED LLC layer laminated and tri-laminate laminated shingles. are CARBON MONOXIDE DESCRIPTION OF WORK :The existing asphalt shingle roofs of 5-6 E Water Place have reached the end of their usable life.The existing I. `1 °S. roofs are approximately 25 years old.Project scope will include removal and disposal of the existing roof r r .. composed of multiple thicknesses of coated and surfaced DETECTORS REQUIRED Snow guard above II EVALUATION SUBJECT: fiberglass mat,cut and bonded together in different patterns. THROUGHOUT DWELLING assembly,and mnallationora new roof assembly. ir patio area The weather side is surfaced with mineral roofing granules. UNIT PER CITY OF ASPEN ' y ti CERTAINTEED ASPHALT SHINGLES• and the back side is surfaced with a mineral release agent. MUNICIPAL CODE 8.15 j • I 1.0 EVALUATION SCOPE 3.4 Accessory Shingles: USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? , Existing gutter to be Compliance with the followingcodes: 3.4.1 HI and Ridge Shingles:Hipand ride shingles are r Existing gutter to be 7 eplaced like for like P B 9 g replaced like for like. �t • 6 A G.r-• •2021,2018,2015.2012 and 2009 International Building factory-made shingles to be used for covering hips and 04 Downspout drains to Code°(IBC) ridges.The hip and ridge shingles are composed of the It should be known that this review shall CLASS OF WORK Residential FIRE SPRINKLER TYPE P • not relieve the applicant of their • lower roof Isame materials as the root shingles.Some of the hip and •2021, 2018, 2015. 2012 and 2009 International ridge shingles have perforations that extend from the top ofig AI responsibility to comply with the REQUIRED SPECIAL Residential Code'D(IRC) the cut-out to the top of the shingle,which facilitate the requirements of the City of Aspen BUILDING TYPE(IRC) - Existing downspout , INSPECTIONS ■2013 Abu Dhabi lntemational Building Code(ADIBC) tearing of the shingle into three or four equal pieces.Others Municipal Code.Pursuant to t to be replaced like Sec.26.104.050,anypermit or approval • \� I 'The ADIBC is based an the 2009 IBC.2009 IBC code sections referenced are manufactured as single hip and ridge units pP for like.Drains to in Iles sport era Inc serve sections In Inc AOIBC. issued in error or otherwise not in CONSTRUCTION TYPE ENERGY CODE COMPLIANCE Existing gutter to be ' , landscaping 3.4.2 Starter Strip Shingles: Starter Strip shingles are conformitywith the requirements of this replaced like for like. - -e Properties evaluated: G • factory-made shingles to be used as the starter course Title,shall be void.Similarly,any permit WORK CHANGES BUILDING Downspout to _Alliliple3p1 •Weather resistance (under the first course of roof shingles).The Starter Strip or approval issued in reliance upon or OCCUPANCY GROUP IIBC) FOOTPRINT? landscaping • _ I ■Fire classification shingles are composed of the same materials as the roof pp p shingles. The shingles are supplied in 7-inch-b 36-inch- as a result of,a materially false r ' ` II It ► •Wind resistance n9 n9 P Y statement or representation made in CODE EDmONS 2015 ARC TOTAL SPA SQ.FT. Hardscape walkway %. 1 r 2.0 USES long (178 by 914 min): 10-inch-by-36-inchJong (254 by the process of obtaining the permit or 914 mm);or 7-inch by-393/a inch-long(178 by 1000 min) development approval shall,likewise, miiiThe CertainTeed asphalt shingles described in this report strips. As an alternative to facto made starter strips. compl with ASTM D3462 and are Class A roof coven s factory-made �' be void.Any person having received a OTHER CODE EDITIONS TOTAL SNOWMELT SQFT. /a► - • •� 4! Ill - Y n9 starter strips can be formed by removing the lower tab _ - ' Hardscape walkway when installed as described in this report. portions of the factory-made shingles except for the void or voidable permit or approval 3.0 DESCRIPTION Presidential Shake and Presidential Shake TL shingles.For shall not be relieved from having to HISTORIC PROPERTY? No TOTAL POOL SQ.FT. S Presidential Shake and Presidential Shake TL shingles.the comply with all applicable terms and �-� ' /►• v d 3.1 General: conditions of this Title and the City shall I•- E F Presidential Starter shingles consist of one 13!.-inch-wide- • • _ s CertainTeed asphalt shingles are available as three-tab. by-40-inch-long(337 mm by 1016 mm)base shingle and not be estopped from fully enforcing FIRE SPRINKLER EXISTING? four-tab, no cut-out and laminated asphalt shingle roof one 11t1.-inch-wide•by-40•inch-long(286 min by 1016 min) same. v, t -• covering materials.See Table 1 and Figure 1 for recognized base shingle. - - - R. product names, shingle types, manufacturing locations, overall dimensions,installed weights,maximum exposure to 3.5 Fasteners: I Roof Assembly Listed Below the weather,and fastening details.The shingles are self- Fasteners must comply with ASTM F1667 and must , CV,t_V,ICL D sealing by means of adhesive strips located on either the be minimum No.12 gage(0.105-inch-diameter(2-67 mm) eoothor cello nr tho„nnorsldo Coo Fir,,ro 1 In,odhoc,ue 06/08/2023 D 0 Proposed Roof Assembly Drawing—Show all layers/components from the roof sheathing up. Each component must be clearly labeled to include FORCOOECOLKINICE APPUCATION ACCEPTED DATE: 2023-06-08 PERMIT NUMBER: 0060-2023-BROF linzhid product and manufacturer name and existing to remain components and number of layers. Show flashing and ice barrier. COMMUNITY DEVELOPMENT DEPARTMENT 000 0 Existing roofing and number of layers: 3 layers: 3/4" CDX ply, #15 bldg. paper, asphalt shingles 41j;j0 BUILDING PERMIT COVERSHEET TT CITY OF ASPEN PROPERTY INFORMATION ADDRESS', 6 E WATER PL UNIT'. PARCEL ID: 273513204006 LEGAL DESCRIPTION: WATER PLANT AFFORDABLE HOUSING OWNER: WHEATLEY KIRK CITY•OF ASPEN PERMIT CONTRACTOR: CITY OF ASPEN-ASSET MANAGEMENT PERMIT NO.0060-2023-BROF DESCRIPTION OF WORK :The existing asphalt shingle roofs of 5-6 E Water Place have reached the end of their usable life.The existing OWNER WHEATLEY KIRK roofs are approximately 25 years old.Project scope will include removal and disposal of the existing roof - assembly,and installation of a new roof assembly. ADDRESS 6 E WATER PL PARCEL ID 273513204006 USE OF BUILDING Multi-Family FIRE SPRINKLER REQUIRED? 1 CLASS OF WORK Residential FIRE SPRINKLER TYPE BUILDING TYPE(ARC) REQUIRED SPECIAL INSPECTIONS CONSTRUCTION TYPE ENERGY COOS COMPLIANCE OCCUPANCY GROUP(IBC) WORK CHANGES BUILDING FOOTPRINT? CODE EDITIONS 2015 IRC TOTAL SPA SQFT. OTHER CODE EDITIONS TOTAL SNOWMELT SEISE. HISTORIC PROPERTY? No TOTAL POOL SOFT. FIRE SPRINKLER EXISTING?