HomeMy WebLinkAboutFile Documents.13 E Water Pl.0090-2022-BRES (15) APPLICATION ACCEPTED DATE: 2022-07-14 PERMIT NUMBER: 0090-2022-BRES Field Plan Set Must Be Printed In Color 11►���1� 1CITY OF COMMUNITY DEVELOPMENT DEPARTMENT 1 �101 ASPEN ;; ,, CITY OF ASPEN BUILDING PERMIT COVERSHEET • CITY OF ASPEN, These plans musta ept at the PERMIT NO 0090-2022-BRES buildin site orinspection delays mayoccur.Construction PROPERTY INFORMATION shall conform to these plans.All changes shall be approved by ADDRESS: 1034 E COOPER AVE 11A UNIT: lifiliging official. PARCEL ID: 273718113030 LEGAL DESCRIPTION: CHATEAU EAU CLAIRE READ THIS OR FAIL YOUR INSPECTION! O'lfiuf1 ER Harold Craft OWNER: CRAFT HAROLD D - -- _- --—_- PERMIT CONTRACTOR: BOWDEN DEVELOPMENT CORP Furred&Dropped Ceilings,Soffits,and Walls SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, 200This 5 IBC 803.13the ADDRESS PLUMBING,MECHANICAL,OR This applies to the attachment of finishes or furring to any FIRE SPRINKLER WORK assemblies that are required to be either fire-rated or 1034 E Cooper#11 A non-combustible and is separate from the fire-rated --- - -- - -- DESCRIPTION OF WORK Interiorrenovationsincluding,adjusting walls n bedroom closets,extending the kitchen island,moving kitchen assembly requirement SMOKE ALARMS AND CARBON MONOXIDE sinka nd dishwasher. P1* RCEL ID 273718113030 HETECTORS REQUIRED THWalls,Ceilings&Soffits:If furred 1%inches or ROUGHOUT DWELLING less,do one of the following: UNIT PER CITY OF ASPEN 4.Fill spaces with Class A material. MUNICIPAL CODE 8.15 5.Fill spaces with inorganic or non-combustible material. 6.Fire block 8 feet in all directions. USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes Walls:If set out(furred)greater than 1%inches, 1 It should be known that this review shall - do one of the following: not relieve the applicant of their 4.Use a Class A finish material(such as drywall). responsibility to comply with the CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA13 5.Use non-combustible framing. requirements of the City of Aspen 6.Protect both sides with fire sprinklers. Municipal Code.Pursuant to Sec.26.104.050,any permit or approval REQUIRED SPECIALissued in error or otherwise not in BUILDING TYPE(IRC) Townhouse Ceilings&Soffits:If dropped(furred)greater conformity with the requirements of this INSPECTIONS than 1'/a inches: Title,shall be void.Similarly,any permit Framing members,hangers,and other assembly or approval issued in reliance upon or members must be non-combustible.You may not as a result of,a materially false CONSTRUCTION TYPE VA ENERGY CODE COMPLIANCE Prescriptive Table use wood. statement or representation made in In Type III and V construction only,you may use fire the process of obtaining the permit or retardant treated wood or non-combustible framing. development approval shall,likewise, be void.Any person having received a WORK CHANGES BUILDING `i void or voidable permit or approval OCCUPANCY GROUP(IBC) R-2 No FOOTPRINT? MI ® ► _t shall not be relieved from having to Girl ) comply with all applicable terms and conditions of this Title and the City shall Ma.,.,-,.., not be estopped from fully enforcing CODE EDITIONS 2015 IBC TOTAL SPA SQ.FT. o_<a,.a;,,,. same. OTHER CODE EDITIONS 2015 1 ECC,2015 1 EBC,20151 PC, TOTAL SNOWMELT SQ.FT. D., rsiltWila 2020 NEC s''R10'^'""EDT's" ophiev22/2022 2009 IBC 601 Fire Resistive Requirements for May 4,2022 +-+ ZONING HISTORIC PROPERTY? No TOTAL POOL SQ.FT. Type of Construction: VA Primary Structural Frame: 1 hr Client: Structural Engineer: (beams supper.°more than 2 floors or more than 1 floor a I roof, and all columns moat Ice Individually encapsulated) Bowden Homes DB Structural Design Ltd. E Exterior Bearing Walls: 1 hr 602 E Main St.#102a 1229 Sage Ct. FIRE SPRINKLER EXISTING? Yes Interior Bearing Walls:1 hr Aspen,CO 81611 Rifle,CO 81650 Floors/Ceilings:—1— (Iii.hr Attention:Mark Janian (970)319-5934 kreAei-..i) Roof:1 hr CD FC Reference: 1034 E.Cooper,Unit 11 Aspen,CO 81611 10/27/2022 Pi) To Whom It May Concern: o i'Lfi{If�iYrl�r1.1i18UP� The intent of this letter is to inform the reader that DB Structural Design Ltd.has been retained by S.— �w� ]imp Bowden Homes to provide structural engineering design services as the engineer of record for the Q) above referenced project.The scope of services will be determined during demolition,during which, If Dwelling Separation walls,floors or ceiling is modified or disturbed then DB Structural Design Ltd.will be on site to evaluate existing structure and assess the structural Q) proper fire separation assemblies shall be required as listed below: modifications necessary to accommodate this remodel. J Identify all dwelling separations that could be disturbed during this project Sincerely, (walls and floor/ceiling assemblies). _/oenygowucyip, Provide listed 1 hour fire rated assemblies. �' 50e/'% The dwelling separation walls must have an STC sound rating of 50 or FIRE RATED gorrof/ceeiQ REQUIRED /(�''II oNaC`�=�/ greater. assemblies are required to have a DB Structural Design Ltd. fire-resistive rating,recessed fixtures shall g be installed such that the required fire Nate Decker,PE,SE If there is a dwelling above,the ceiling assembly must have an STC sound resistance will not be reduced(IBC 714.4.2) rating of 50 or greater. If there is a dwelling below and a floor finish other than carpet is proposed, provide a spec for an underlayment product providing an IIC sound rating of Any recessed light fixtures 75%of lamps in permanently 50 or greater. in contact with insulation installed light fixtures shall be must be IC rated. high efficacy-IECC R404.1 The original listing instructions for each assembly should be printed on the plans for use by the contractor and inspector.This applies to assemblies that will have more than 32 sqft of disturbance;if less,the assembly may be Dwelling Separation Required-2015 IBC patched as existing.2015 IBC 420,1207 -708 Fire Partitions,711 Horizontal Assemblies: Walls and floor/ceilings separating dwelling units shall have a fire-resistance rating of at least 1 hour.Walls shall extend from the top of the floor assembly below to the underside of the floor or roof slab or deck above or to the fire-resistance-rated floor/ceiling assembly above. -714:Penetrations must be protected by a through-penetration firestop system.Recessed fixtures shall not reduce the required fire resistance by use of a listed fixture,a listed firehood,or a drywall assembly meeting the required fire resistance.Exhaust fans require ceiling radiation damper. -1207 Sound Transmission:Separating walls and floor/ceilings shall have an RECE STC rating of at least 50.Floor/ceilings shall have an IIC rating of at least 50. RECEams 07/11 POPC01 wuwsE ASP: BUILDING DE' T