HomeMy WebLinkAboutFile Documents.506 Walnut St.0053-2023-BRES (6) APPLICATION ACCEPTED DATE: 2023-04-12 PERMIT NUMBER: 0053-2023-BRES I Field Plan Set Must Be Printed In Color 10Ik�
COMMUNITY DEVELOPMENT DEPARTMENT �1��/� i0P00
00
LBUILDINGPERMITCOVERSHEET
�� :� CITY:OF ASPEN CITY OF
CITY OF ASPEN J ASPEN
PERMIT NO+ 0053-2023-BRES
PROPERTY INFORMATION ��� These plans muffs eKeept at the
building site or inspection
delays may occur.Construction
ADDRESS: 506 WALNUT ST UNIT: shall conform to these plans.All
OVVN ER
PARCEL ID: 273707319002 LEGAL DESCRIPTION: WALNUT STREET TOWNHOMES Edward E Mack Trust changes shall be approved by
OWNER: MACK EDWARD E TRUST - Aliging official.
PERMIT CONTRACTOR: GARVIK CONSTRUCTION INC ADDRESS 506 Walnut SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
• - PLUMBING,MECHANICAL,OR
•
DESCRIPTION OF WORK Interior alteration of condo including removal of existing basement handrail and construction of new wall,door, FIRE SPRINKLER WORK
and handrail at edge of stair for sound isolation. PARCEL ID 27370731 9002 SMOKE ALARMS AND
CARBON MONOXIDE
. - DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
USE OF BUILDING Single Family FIRE SPRINKLER REQUIRED? Yes
1 It should be known that this review shall
CLASS OF WORK Residential FIRE SPRINKLER TYPE NFPA 13 D not relieve the applicant of their
responsibility to comply with the
requirements of the City of Aspen
REQUIRED SPECIAL Municipal Code.Pursuant to
BUILDING TYPE(IRC) Two family Sec.26.104.050,any permit or approval
INSPECTIONS issued in error or otherwise not in
conformity with the requirements of this
Title,shall be void.Similarly,any permit
CONSTRUCTION TYPE VB ENERGY CODE COMPLIANCE or approval It as a result of,of,sue in reliance upon or
a materially false
statement or representation made in
the process of obtaining the permit or
WORK CHANGES BUILDING development approval shall,likewise,
OCCUPANCY GROUP(IBC) FOOTPRINT? No be void.Any person having received a
void or voidable permit or approval
shall not be relieved from having to
comply with all applicable terms and
conditions of this Title and the City shall
CODE EDITIONS 2015 IRC TOTAL SPA SQ.FT.
not be estopped from fully enforcing
same.
OTHER CODE EDITIONS 2015 IEBC,2020 NEC TOTAL SNOWMELT SQ.FT.HISTORIC PROPERTY? No TOTAL POOL SQ.FT. ��p05��yyyyO��l��yyyyu2tt1�023
REFERENCES FROM 2015 IRC VEMIEMED
Fyfi�y{AIGrMMIO CE
CV/A=crawl space ventilation required,sec.R408.1 Access required,R408.4 j imp
FIRE SPRINKLER EXISTING? Yes EE=emergency escape required sec R310.1
EU=enclosed usable space under stairs shall be%"Gyp,sec R302.7
G/D=garage/dwelling separation,sec R302.5 and R302.6
STC=Sound transmission class not less than 45 at dwelling separations,app
K
RV=roof and rafter ventilation required,R806.1
A=attic access 22"x 30",30"headroom above,R807.1
SA=smoke alarms installed to NFPA 72 requirements,sec R314
CO=carbon monoxide detector per City Ordinance 41 series 2008
SG=safety glazing required,sec R308.4
GR=guardrails,36"min ht,4"max opening;req at 30"drop any point w/in 36"
horizontally,sec R312
WFP=window fall protection-operable window<24"AFF&>72"above
grade:use opening control device listed to ASTM F2090,sec R312.2
General Electrical Requirements HR=handrails 34"-38"ht,sec R311.7.8
Any areas affected by the renovation must be brought SI=stairway illumination,sec R303.7
to the current electrical code including: PD=protect against decay,sec
u
p REFERENCES FROM 2015 IMC
tamperproof receptacles(NEC 406.12), V=bathroom and balanced whole house mechanical ventilation req.
ground-fault circuit interrupter protection(NEC 210.8), Ordnance 40,2016
DE=clothes dryer exhaust,sec 504.Makeup air req'd if over 200 CFM
arc-fault protection(NEC 210.12), AS=access and service space for maintenance req'd,sec 306
receptacle spacing(NEC 210.52)etc. MA=make up air required if hood exhausts greater than 400 CFM,sec 505.2
ET=exhausts terminate 3'from prop line and openings,10'from intakes,
501.3.1
IT=intake openings 10'from lot line&contaminant sources(vents,streets),
401.4
D=fasten and seal all ductwork per 603.9
REFERENCES FROM 2015 IFGC
DV=direct vent req'd,sec 303.3
CA=combustion air not taken from bedrooms,bathrooms or
storage sec 303.3
OD=outdoor appliances must be listed for outdoor use,sec 303.6
REFERENCES FROM 2015 IECC
F=new or replacement glazing shall not exceed 0.28 U-Value,NFRC label
required,Ordinance 40,2016
L=75%of lamps in permanently installed lights must be high efficacy,sec
R404.1
SE=Continuous air barrier required;all exterior joints,cracks,and holes to be
caulked,gasketed,sealed,table R402.4.1.1
REFERENCES FROM 2014 NEC
EP=electric panel'happy space'30"x36"x78",not in storage,sec 110.26