Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2 2023-05-22 108 Midland Site Plan and Mech Sections_Supplemental
A0.02 PROPOSED SITE PLAN TREE REMOVALS NOT FOR CONSTRUCTION 5/22/2023PERMIT + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 SET REBAR & CAP LS No. 38342 FOUND MONUMENT AS DESCRIBED SITE LEGEND EASEMENT FENCE PROPOERTY LINE EXISTING GRADE PROPOSED GRADE SETBACK LINE TREE TO BE RETAINED AS REQ'D TREE TO BE REMOVED TREE LEGEND EXISTING HOUSE CONCEPTUAL LOCATION AND FOOTPRINT OF PROPOSED HOUSE LIGHTING LEGEND 26.02 IN-GRADE LIGHT FIXTURE 26.03 RECESSED WALL LIGHT SITE NOTES ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0" ② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARITION TYPES ③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESSS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE SITE NOTES① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0"② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARITION TYPES③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESSS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE N 10' 10 ' 25 ' 2 5 ' 39 '-5.5" 1 2 3 4 5 6 7 8 1 0 1 1 2 3 2 2 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 4 3 3 3 1 9 1 2 1 3 1 4 2 0 1 8 1 9 1 5 1 7 1 6 2 1 3 7 5 0 4 9 4 8 4 7 4 6 4 5 4 4 4 3 4 2 4 1 4 0 3 9 3 8 3 6 3 5 5 2 5 4 5 6 5 5 6 5 6 3 6 4 5 1 5 3 5 8 6 0 5 9 6 2 5 7 83'-4.5" 3 2 PARKING SPACE (TYP.) FIRE TRUCK TURNAROUND HOSE BIB HOSE BIB HOSE BIB HOSE BIB AUTOCOURT OPEN NO FENCE ACCESS P R O P E R T Y L I N E S I D E S E T B A C K REAR SETBACK FRONT SETBACK S I D E S E T B A C K P R O P E R T Y L I N E MIDLAND AVE CONCRETE SIDEWALK MECH ENCLOSURE TR A S H 798 0 79 8 5 79 8 0 7 9 8 0 7975 7 9 7 5 7 9 7 0 797 0 797 5 79 6 5 796 0 7 9 6 5 796 0 79 6 5 797 0 796 0 797 0 797 5 7 9 8 5 7980 104 MIDLAND AVE 10' 15' 46 '-9 .5 " 2 0 '- 1 0 . 5 " 12'-6 1/2" KEYNOTES 2.01 EXISTING TREE: REF: SURVEY 26.02 IN GRADE LIGHT FIXTUREl REFER TO SITE PLAN & RCPs; REF: LIGHT FIXTURE SCHEDULE 26.03 RECESSED WALL LIGHT; REFER TO SITE PLAN & RCPS; REF: LIGHT FIXTURE SCHEDULE 32.02 STONE RETAINING WALL; REF: CIVIL 32.04 STONE FENCE 32.05 FIRE TRUCK TURNAROUND; REF: CIVIL SCALE: 1" = 10'1Proposed Site Plan 0 5'10'20' MECHANICAL ENCLOSURE SECTIONS NOT FOR CONSTRUCTION 5/22/2023PERMIT + ANDERSSON / WISE 807 Brazos St #800 Austin TX 78701 RED 1001 Grand Ave #103 Glenwood Springs CO 81601 © These documents have been specifically prepared for 108 Midland Avenue. They are not suitable for use on other projects or in other locations without the approval and participation of the architect. Reproduction prohibited without approval of the architect. 2023 Haynes Residence 108 Midland Avenue Aspen, CO 81611 STONE SIDING WOOD TIMBERS AND TRIM HORIZONTAL SIDING CORRUGATED METAL ROOFING ELEVATION MATERIAL METAL CHIMNEY METAL TBD ELEVATION NOTES ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0" ② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARTITION TYPES ③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE ① FIRST FLOOR FINISH ELEVATION 100'-0" = 7975'-0"② SEE SHEET G0.40 AND G0.41 FOR WALL AND PARTITION TYPES③ SEE SHEET A6.00 FOR WINDOW TYPES AND SCHEDULES ④ SEE SHEET A6.50 FOR DOOR TYPES AND SCHEDULES ⑤ SEE SHEET G0.50 FOR FINISH, EQUIPMENT, AND ACCESSORIES SCHEDULE ⑥ ALL DIMENSIONS ARE TO STRUCTURAL GRID, FACE OF CONCRETE, OR FACE OF FRAMING UNLESS NOTED OTHERWISE ⑦ ALL WINDOW LOCATION DIMENSIONS ARE REFERENCED TO THE CENTERLINE OF WINDOW UNIT. SEE SHEET A6.00 FOR ROUGH OPENING DIMENSIONS ⑧ ALL ARCHITECTURAL STEEL OR STEEL W/ WELDS EXPOSED TO VIEW SHALL BE GROOVE OR PUDDLE WELDED AND GROUND SMOOTH FOR A SEAMLESS APPEARANCE, UNLESS OTHERWISE DETAILED OR APPROVED BY ARCHITECT ⑨ ALL EXTERIOR ELECTRICAL OUTLETS AND HOSE BIBS ARE LOCATED 1'-3" A.F.F. TO CENTERLINE 1'-6"12'-11"1'-6" 6' - 0 " STONE FENCE STONE FENCE MECHANICAL ENCLOSUREBIKE STORAGE 1'-6"16'-10 1/2" 6' - 0 " STONE FENCE MECHANICAL ENCLOSURE OFFICE SCALE: 1/2" = 1'-0"1Mech Enclosure N-S Section 0 1'2'4' SCALE: 1/2" = 1'-0"2Mech Enclosure E-W Section 0 1'2'4'