Loading...
HomeMy WebLinkAbout110 Neale.Response.20201013S S C S S C C C S S S C STAIR 101 REC ROOM 102 BEDROOM 103 BATHROOM 104 BEDROOM 108 BATH 106 BEDROOM 110 MUDROOM 115 POWDER 117 BEDROOM 119 CLO. 105 ENTRY 118 VESTIBULE 109 GARAGE 116 CLO. 120 BATH 121 CRAWL SPACE BEDROOM 113 CLO. 107 BATH 111 BATH 112 CLO. 111 CLO. 112 1 A-201 2 A-201 3 A-202 4 A-202 9 9 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND F S CO D P C W SPK REFLECTED CEILING PLAN LEGEND RECESSED DOWNLIGHT CAN RECESSED DOWNLIGHT CAN (WET) RECESSED PIN/ PUCK WALL-MOUNTED FIXTURE SURFACE / SEMI-SURFACE MOUNT SMOKE/CO DETECTOR CHANDELIER PENDANT TYP. LINEAR LED UNDERCAB RECESSED DIRECTIONAL PIN SPEAKER CEILING SPRINKLER HEAD BATH FAN TROFFER/ STRIP LIGHT RECESSED LED MULTIPLE SPOTS (2) RECESSED LED MULTIPLE SPOTS (3) TYP. LINEAR LED COVE LIGHTING R S WALL SPRINKLER SUPPLY VENT RETURN VENT N 0 4'8'12'SCALE: 3/16" = 1'-0"1 GARAGE LEVEL RCP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-704 GARAGE LEVEL RCP 10/13/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 HPC FINAL SUBMITTAL 08/24/20 FF W C C C C CC C S S SS S S S S SS 1 A-201 2 A-201 3 A-202 4 A-202 9 9 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L RG KITCHEN 212 BREAKFAST 213 LIVING ROOM 214 DINING ROOM 202 MASTER BEDROOM 209 MASTER BATH 205 CLOSET 208 CLOSET 207 WC 206 LAUNDRY 204 STAIR 201 POWDER 203 PANTRY 211 EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND F S CO D P C W SPK REFLECTED CEILING PLAN LEGEND RECESSED DOWNLIGHT CAN RECESSED DOWNLIGHT CAN (WET) RECESSED PIN/ PUCK WALL-MOUNTED FIXTURE SURFACE / SEMI-SURFACE MOUNT SMOKE/CO DETECTOR CHANDELIER PENDANT TYP. LINEAR LED UNDERCAB RECESSED DIRECTIONAL PIN SPEAKER CEILING SPRINKLER HEAD BATH FAN TROFFER/ STRIP LIGHT RECESSED LED MULTIPLE SPOTS (2) RECESSED LED MULTIPLE SPOTS (3) TYP. LINEAR LED COVE LIGHTING R S WALL SPRINKLER SUPPLY VENT RETURN VENT N 0 4'8'12'SCALE: 3/16" = 1'-0"1 MAIN LEVEL RCP 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-705 MAIN LEVEL RCP 10/13/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 HPC FINAL SUBMITTAL 08/24/20 COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-707 EXTERIOR LIGHTING SPECIFICATIONS 10/13/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 HPC FINAL SUBMITTAL 08/24/20 PREMIER 4-FIN SCONCE #E20141 AND #E20135 SHOWN IN SATIN NICKEL 30 Liberty Ship Way Suite 3150 · Sausalito CA 94965 · T +1.415.778.4300 F +1.415.778.4319 · boydlighting.com Designed by Doyle Crosby. All products FOB Colorado Springs, CO. Please consult our website for current specifications. © 2006, 2008 Boyd Lighting E20141 Premier, 4-Fin Grande Sconce 14½" 22"16" 16" Net Wt. Height Width Projection (Cu/Al) 225 /8 " 14½" 16" 38/18 lbs 575 mm 368 mm 406 mm 17.2/8.2 kg Backplate: 125 /8 " H x 6¼" W; 321 x 159 mm Cage Height: 167/8"; 429 mm Center of outlet box to top of fixture: 31/8"; 79 mm For ADA compliance, height of center of outlet box above finished floor: 99½"; 2527 mm UL listed (or equivalent) for wet locations Diffuser: satin white acrylic Fixture constructed of either solid copper or solid aluminum Unlacquered satin copper has no protective coating and will patina over time LAMPING Incandescent • One, Medium base, A-21, 150w max • Compatible with LED Screw-in lamps Lamp not included with fixture. LED: GU-24 Base lamping may be able to meet current energy legislation; available upon request Fluorescent • One, CFTR26W/GX24q or One, CFTR32W/GX24q or One, CFTR42W/GX24q • Universal 120v-277v • Outdoor rated at -17˚C Upcharges will apply for fluorescent remote dimming. Contact your local Boyd rep with the specification of the dimming control system being used. HID - Ceramic Metal Halide • One, CMH39W/G8.5 • Outdoor rated at -30˚C Lamp not included with fixture. STANDARD FINISHES Copper • Antiqued Copper • Satin Copper (unlacquered) SPECIALTY FINISHES Copper • Satin Nickel Aluminum • Coffee Bean • Gloss White • Silver Fog OPTIONAL • Fluorescent Remote Dimming E20135 Premier, 4-Fin Sconce Net Wt. Height Width Projection (Cu/Al) 17" 10½" 127/8" 26/14 lbs 432 mm 267 mm 327 mm 11.8/6.4 kg Backplate: 10½" H x 5¼" W; 267 x 133 mm Cage Height: 12¼"; 311 mm Center of outlet box to top of fixture: 3"; 76 mm For ADA compliance, height of center of outlet box above finished floor: 94"; 2388 mm UL listed (or equivalent) for wet locations Diffuser: white cased glass Fixture constructed of either solid copper or solid aluminum Unlacquered satin copper has no protective coating and will patina over time LAMPING Incandescent • One, Medium base, A-21, 150w max • Compatible with LED Screw-in lamps Lamp not included with fixture LED: GU-24 Base lamping may be able to meet current energy legislation; available upon request Fluorescent • One, CFTR26W/GX24q-3 • Outdoor rated at -10˚C • Voltage 120v or 277v (non-dimming) Upcharges will apply for fluorescent remote dimming. Contact your local Boyd rep with the specification of the dimming control system being used. Lamp not included with fixture. STANDARD FINISHES Copper • Antiqued Copper • Satin Copper (unlacquered) SPECIALTY FINISHES Copper • Satin Nickel Aluminum • Coffee Bean • Gloss White • Silver Fog OPTIONAL • Fluorescent Remote Dimming 10½"12 " 17"12¼" PREMIER 4-FIN LANTERN #10125 SHOWN IN SATIN COPPER 30 Liberty Ship Way Suite 3150 · Sausalito CA 94965 · T +1.415.778.4300 F +1.415.778.4319 · boydlighting.com All products FOB Colorado Springs, CO. Designed by Doyle Crosby. Patent Design (Premier only): D532,147. Please consult our website for current specifications. © 2004 Boyd Lighting 10125 Premier, 4-Fin Lantern Net Wt. Height Diameter Cage Height (Cu/Al) Specify 121 /8 " 12¼" 19/12 lbs 308 mm 311 mm 8.6/5.4 kg Canopy: 5" dia x 1"; 127 x 25 mm UL listed (or equivalent) for damp locations Diffuser: white cased glass Fixture constructed of either solid copper or solid aluminum REQUIRED INFORMATION • Height Overall: 18" - 42"; 457 - 1067 mm LAMPING Incandescent • One, Medium base, A-21, 150w max • Compatible with LED Screw-in lamps LED: GU-24 Base lamping may be able to meet current energy legislation; available upon request Lamp not included with fixture Fluorescent • One, CFQ26W/G24q-3 • Voltage 120v or 277v (non-dimming) Upcharges will apply for fluorescent dimming. Contact your local Boyd rep with the specification of the dimming control system being used. Lamp not included with fixture. STANDARD FINISHES Copper • Antiqued Copper • Polished Copper • Satin Copper Aluminum • Satin Aluminum • Black Granite • Cinnamon Bronze • Matte White SPECIALTY FINISHES Copper • Polished Nickel • Satin Nickel Aluminum • Rubbed Bronze • Silver Fog OPTIONAL • Fluorescent Dimming 5" 12¼" 12 " 10130 Premier, 4-Fin Sconce Net Wt. Height Width Projection (Cu/Al) 17" 10½" 127 /8 " 26/14 lbs 432 mm 267 mm 327 mm 11.8/6.4 kg Backplate: 10½" H x 5¼" W; 267 x 133 mm Cage Height: 12¼"; 311 mm Center of outlet box to top of fixture: 3"; 76 mm For ADA compliance, height of center of outlet box above finished floor: 94"; 2388 mm UL listed (or equivalent) for damp locations Diffuser: white cased glass LAMPING Incandescent • One, Medium base, A-21, 150w max • Compatible with LED Screw-in lamps Fluorescent • One, CFQ26W/G24q-3 • Voltage 120v or 277v (non-dimming) Upcharges will apply for fluorescent remote dimming. Contact your local Boyd rep with the specification of the dimming control system being used. Lamp not included with fixture. STANDARD FINISHES Copper • Antiqued Copper • Satin Copper Aluminum • Satin Aluminum • Black Granite • Cinnamon Bronze • Matte White SPECIALTY FINISHES Copper • Satin Nickel Aluminum • Rubbed Bronze • Silver Fog OPTIONAL • Fluorescent Remote Dimming 10½"12" 17"12¼" Low Voltage, Recessed Downlight - The Minus downlight series by Apure brings sophistication to interior spaces with its never-before- seen performance combined with a glare-free appearance. A single high performance LED is combined with precision-focusing optics to create an unprecedented light fixture. A robust proprietary driver ensures equal light output, regardless of voltage drops. High-tech microprocessor-controlled, thermal management ensures reliability and a long life. Construction •Hard anodized aircraft grade aluminum heat sink •1” black signature apure magnetic snap-in square louver, Designed by Porsche Design Studio, featuring propriety optics for maximum light output •50,000 hours LED lifetime •Fixture weight: 720g (1.58lbs) •Operating Temperature: -10ºC - 50ºC •Not intended for steam rooms / saunas! Light output •1140lm source light output •Sharply defined 20° or 40° light output •High performance Cree LED at various color temperatures available •Color rendering index 90 •Microprocessor controlled thermal protection MINUS TWO Project: Type: 1.0” (25mm) 1.0” (25mm) Front view actual size Electrical Specifications •Class 2 Fixture •14W Power Consumption •24V DC Input •Either MLV dimming or Lutron Hi-Lume 0.1% dimming. Dimming protocol is specific to each fixture, please check ordering info. •100W 24V DC Power supply required (powers up to 4 fixtures) •Recommended wire, not included: min. 16 AWG Plenum rated (CMP) up to 150ft from remote transformer. Plenum rating not required in non plenum ceiling. Trimless Recessed Installation •Standard installation for the Minus Two is accomplished with the use of our universal bracket (AM2-BRK-U) shown above, which allows the Minus Two to be installed within new or pre-existing drywall ceilings. For complete specifications, please see the Universal Drywall Bracket cutsheet. •8.25” X 8.25” (209mm X 209mm) square cutout required Listings / Patents •ETL listed, Certified to UL 2108 and UL 8750 •Airtight rated / Chicago Plenum rated •IC rated / Wet location listed •Patent Pending © 2019. apure distribution LLC. all specifications and dimensions subject to change without notice. visit www.apure-system.com to download the latest versions of all specifications. apure distribution LLC, 5555 Biscayne Blvd, Fourth Floor, Miami, Florida | phone: +1 305 351 1025 | Patent Pending ORDERING INFORMATION SERIES NO. ORDERING EXAMPLE AM21F-4090SA MODEL AM21F-____ AM - Minus Series TYPE ORIENTATION 1 - LED2 - Minus Two F - Fixed TEMPERATURE 27 - 2700k 30 - 3000k40 - 4000k CRI 90 - 90 CRI LENS S - 20° Spot F - 40° Flood 4.7” (120mm) 4.7” (120mm) Top view .77” (19.4mm) Universal Drywall Bracket (Required Accessory, Sold Seperately) PROTOCOL A - Standard MLV L - Lutron Hi-Lume 0.1% 01/19 rev1 page 1 of 2 EXTERIOR SCONCE - CUSTOM BLACK FINISH EXTERIOR PENDANT - CUSTOM BLACK FINISH EXTERIOR CAN 09 11 08 07 06 79 0 5 04 03 02 01 +03.93' +03.69' AUTOCOURT 79 1 0 + 10.00 + 09.00 + 08.00 + 07.00 + 05.00 + 04.00 + 11.00 + 11.20 + 10.00 + 08.00 +07.25' +04.28' +04.87' +05.46' +06.05' +06.64' +07.23' +07.82' +09.18' +09.41' +10.75+10.25 AREA DRAIN +09.25 + 11.50 EDGE OF EXISTING NEIGHBORS DRIVEWAY BOULDERS AS NEEDED TO SLIGHLTY RETAIN GRADE PROPOSED LANDSCAPE STEPS AT OR WITHIN 12" OF EXISTING GRADE NOTE: LANDSCAPE STEPS ARE MEANT TO FOLLOW EXISTING GRADE AND WILL NOT BE MORE THAN +/- 12" ABOVE OR BELOW EXISTING OR FINISHED GRADE +08.59' PROPOSED PATH LIGHTS FOR SAFETY + 06.00 +11.00 +11.50 AREA DRAIN +07.15 DETAILS L-5.01 0,0,0 ISSUE & REVISION DATES Plot Date: 08/21/20 Project #:389 Drawn By: BM Checked By: GT Ne a l e A v e 11 0 N e a l e A v e As p e n , C O 8 1 6 1 1 LA N D S C A P E A R C H I T E C T U R E ▪ L A N D P L A N N I N G 35 0 M A R K E T S T R E E T | S U I T E 3 0 7 | B A S A L T | C O | 8 1 6 2 1 WW W .C O N N E C T O N E D E S I G N .C O M | 9 7 0 .3 5 5 .5 4 5 7 HOA SUBMITTAL 08/21/20 10/13/20ADDITIONAL DETAIL LIGHTING CUT SHEET1 LANDSCAPE STEPS / PATH ENLARGEMENT3SCALE - 1/4"=1'-0" STONE PATH AND STACKED STONE GARDEN WALL IMAGERY2