Loading...
HomeMy WebLinkAboutExhibit C Revised Application.110 Neale Aveforumphi.com | p. 970.279.4109 | f. 866.770.5585 Aspen: 715 W. Main St, #204 Aspen, CO 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81621 Forum Phi Architecture 715 W Main Street, Aspen CO 81611 July 8, 2020 Dear Members of the Historic Preservation Commission, On May 5, 2020, Forum Phi submitted an application for Major Development Review of an addition to the existing residence at 110 Neale Avenue in Aspen. On June 24, 2020, members of the HPC voted to continue Conceptual Review of the application pending restudy of the roof massing over the dining room. Specifically, the Commission argued that the proposed addition did not comply with Section 11.3 of the HPC Design Guidelines. Section 11.3, under the Mass and Scale heading, requires that new buildings, or in this case additions to existing buildings, “appear similar in scale and proportion with the historic buildings on a parcel.” The commission argued that the continuation of the ridge from the living room through the dining room created a massing condition that was incompatible with the historic resource at 114 Neale, regardless of how that mass might be modulated through depth. The elevation below identifies the area of concern. Forum Phi has redeveloped the roof massing in this zone to limit the ridge height and to further modulate the Neale Avenue elevation. Instead of continuing the ridge height across the living spaces, the design reconsiders the dining room as a connecting element between the master bedroom wing nearest to the historic resource and the living wing on the downhill side of the lot. forumphi.com | p. 970.279.4109 | f. 866.770.5585 Aspen: 715 W. Main St, #204 Aspen, CO 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81621 The proposed design has been considered in accordance with applicable Residential Design Standards. These standards serve as a guide for design within our context, encouraging design at a human scale, requiring consideration of appropriate building materials, and promoting a healthy relationship between building and street. The change in roof massing has not resulted in any changes to the way the design addresses RDS requirements. Significant (but not historic) landscape improvements exist on the site. The project will to the greatest extent practicable retain all trees on the site and does not propose to remove any trees between the house at 110 Neale and the historic resource at 114 Neale or between the house at 110 Neale and Neale Avenue. Thank you for your consideration. We look forward to addressing your comments. Best regards, Kurt Peterson, Project Manager City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet City of Aspen|130 S. Galena Street.| (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 ATTACHMENT 2 - Historic Preservation Land Use Application PROJECT: Name: Location: (Indicate street address, lot & block number or metes and bounds description of property) Parcel ID # (REQUIRED)___________________________________________________________ Applicant: Name: Address: Phone #: _______________________Fax#:___________________E-mail:_______________________________________________ REPRESENTATIVE: Name: Address: Phone #: _______________________Fax#:___________________E-mail:________________________________________________ TYPE OF APPLICATION: (please check all that apply): Historic Designation Certificate of No Negative Effect Certificate of Appropriateness -Minor Historic Development -Major Historic Development -Conceptual Historic Development -Final Historic Development -Substantial Amendment Relocation (temporary, on or off-site) Demolition (total demolition) Historic Landmark Lot Split EXISTING CONDITIONS: (description of existing buildings, uses, previous approvals, etc.) ___________________________________________________________________________________________________________ PROPOSAL: (description of proposed buildings, uses, modifications, etc.) ________________________________________________________________________________________________________ 110 Neale Avenue, Aspen, CO 81611 Forum Phi Architecture, LLC C/O Kurt Peterson 715 W MAIN ST, STE 204 ASPEN CO 81611 (303) 884-7756 kpeterson@forumphi.com x The client is seeking approval for a renovation to the existing residence. 110 Neale Ave contains two structures: one single family residence and one ADU. 273707383002 110 Neale Ave 17 Queen LLC 110 Neale AvenueAspen, CO 81611 Exhibit A X City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet City of Aspen|130 S. Galena Street.| (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 General Information Please check the appropriate boxes below and submit this page along with your application. This information will help us review your plans and, if necessary, coordinate with other agencies that may be involved. YES NO  Does the work you are planning include exterior work; including additions, demolitions, new construction, remodeling, rehabilitation or restoration?  Does the work you are planning include interior work, including remodeling, rehabilitation, or restoration?   Do you plan other future changes or improvements that could be reviewed at this time?   In addition to City of Aspen approval for a Certificate of Appropriateness or No Negative Effect and a building permit, are you seeking to meet the Secretary of the Interior’s Standards for Rehabilitation or restoration of a National Register of Historic Places Property in order to qualify for state or federal tax credits?  If yes, are you seeking federal rehabilitation investment tax credits in Conjunction with this project? (Only income producing properties listed on the National Register are eligible. Owner-occupied residential properties are not.)  If yes, are you seeking the Colorado State Income Tax Credit for Historical Preservation? Please check all City of Aspen Historic Preservation Benefits which you plan to use:  Rehabilitation Loan Fund  Conservation Easement Program  Dimensional Variances  Increased Density  Historic Landmark Lot Split  Waiver of Park Dedication Fees  Conditional Uses  Tax Credits  Exemption from Growth Management Quota System X X X X Exhibit A City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet City of Aspen|130 S. Galena Street.| (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 ATTACHMENT 3 - Dimensional Requirements Form (Item #10 on the submittal requirements key. Not necessary for all projects.) Project: Applicant: Project Location: Zone District: Lot Size: Lot Area: (For the purposes of calculating Floor Area, Lot Area may be reduced for areas within the high water mark, easements, and steep slopes. Please refer to the definition of Lot Area in the Municipal Code.) Commercial net leasable: Existing:__________Proposed:_________________ Number of residential units: Existing:__________Proposed:_________________ Proposed % of demolition: __________ DIMENSIONS: (write N/A where no requirement exists in the zone district) Floor Area: Height Existing:_________Allowable:__________Proposed:________ Principal Bldg.: Existing:_________Allowable:__________Proposed:________ Accessory Bldg.: Existing:_________Allowable:__________Proposed:________ On-Site parking: Existing:_________Required:___________Proposed:________ % Site coverage: Existing:_________Required:___________Proposed:________ % Open Space: Existing:_________Required:___________Proposed:________ Front Setback: Existing:_________Required:___________Proposed:________ Rear Setback: Existing:_________Required:___________Proposed:________ Combined Front/Rear: Indicate N, S, E, W Existing:_________Required:___________Proposed:________ Side Setback: Existing:_________Required:___________Proposed:________ Side Setback: Existing:_________Required:___________Proposed:________ Combined Sides: Existing:_________Required:___________Proposed:________ Distance between buildings: Existing:_________Required:___________Proposed:________ Existing non-conformities or encroachments and note if encroachment licenses have been issued: _____________________________________________________________________________ _____________________________________________________________________________ Variations requested (identify the exact variances needed): ______________________________ ______________________________________________________________________________ 17 Queen LLC 110 Neale AvenueAspen, CO 81611 R-15A 15,160 11,425.47 NA NA 2 1 33.87% 4,336.07 Existing Nonconforming 4,335.19 22'-4"25'22'-4" 12'1"25'NA 3 2 4 NA NA NA 25'-9"25'25'-6" 20'-2"10 20'-2" 26.6%26.4%<30% 110 Neale Ave Exhibit L City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet City of Aspen|130 S. Galena Street.| (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 Agreement to Pay Application Fees An agreement between the City of Aspen (“City”) and Property Phone No.: Owner (“I”): Email: Address of Billing Property: Address: (Subject of (send bills here) application) I understand that the City has adopted, via Ordinance No., Series of 2011, review fees for Land Use applications and payment of these fees is a condition precedent to determining application completeness. I understand that as the property owner that I am responsible for paying all fees for this development application. For flat fees and referral fees: I agree to pay the following fees for the services indicated. I understand that these flat fees are non-refundable. $___________flat fee for ____________________ $____________ flat fee for ____________________________________ $___________ flat fee for ___________________ $_____________ flat fee for____________________________________ For Deposit cases only: The City and I understand that because of the size, nature or scope of the proposed project, it is not possible at this time to know the full extent or total costs involved in processing the application. I understand that additional costs over and above the deposit may accrue. I understand and agree that it is impracticable for City staff to complete processing, review and presentation of sufficient information to enable legally required findings to be made for project consideration, unless invoices are paid in full. The City and I understand and agree that invoices mailed by the City to the above listed billing address and not returned to the City shall be considered by the City as being received by me. I agree to remit payment within 30 days of presentation of an invoice by the City for such services. I have read, understood, and agree to the Land Use Review Fee Policy including consequences for no-payment. I agree to pay the following initial deposit amounts for the specified hours of staff time. I understand that payment of a deposit does not render and application complete or compliant with approval criteria. If actual recorded costs exceed the initial deposit, I agree to pay additional monthly billings to the City to reimburse the City for the processing of my application at the hourly rates hereinafter stated. $________________ deposit for_____________ hours of Community Development Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. $________________ deposit for _____________ hours of Engineering Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. City of Aspen: Property Owner: ________________________________ _______________________________________________ Jessica Garrow, AICP Community Development Director Name: _______________________________________________ Title: ____________________________________________________ City Use: Fees Due: $____Received $_______ Exhibit B Exhibit D RECEPTION#: 629520, 05/23/2016 at 10:55:33 AM, 1 OF 3, R $21.00 DF $1214.00 Janice K. Vos Caudill, Pitkin County, CO After recording return to: Attorneys Title Insurance Agency of Aspen, LLC 715 West Main Street, Suite 202 Aspen, Colorado 81611 GENERAL WARRANTY DEED J' THIS DEED is dated J May 2o16, is granted and made by and between ALICE BRIEN (the "Grantor") and 17 QUEEN LLC, a Colorado limited liability company, whose mailing address is: c/o Millard J. Zimet, P.C., 1315 Mountain View Drive, Aspen, Colorado 8i6ii (the "Grantee"). WITNESS, that the Grantor, for and in consideration of the sum of Twelve Million, One Hundred Forty Thousand and oo/loo U.S. Dollars ($12,140,000.00) and other good and valuable consideration, the receipt and sufficiency of which is hereby acknowledged, hereby grants, bargains, sells, conveys and confirms unto the Grantee and the Grantee's successors and assigns forever, all the real property, together with any improvements thereon, located in all the real property, together with any improvements thereon, located in the City of Aspen, Pitkin County, Colorado, described as: LOT 2, AS SHOWN ON THE SUBDIVISION EXEMPTION PLAT OF 114 NEALE/17 QUEEN HISTORIC LOT SPLIT, according to the Plat thereof recorded May 29,1998 in Plat Book 45 at Page 17; Also known as: 17 Queen Street, Aspen, Colorado 81611. TOGETHER with all and singular the hereditaments and appurtenances thereunto belonging, or in anywise appertaining, the reversions, remainders, rents, issues and profits thereof, and all the estate, rights, titles, interests, claims and demands whatsoever of the Grantor, either in law or equity, of, in and to the above bargained premises, with the hereditaments and appurtenances; TO HAVE AND TO HOLD the said premises above bargained and described, with the appurtenances, unto the Grantee and the Grantee's successors and assigns forever. The Grantor, for herself and for her heirs, successors and assigns, covenants, grants, bargains, and agrees to and with the Grantee, and the Grantee's successors and assigns that at the time of the ensealing and delivery of these presents, the Grantor is well seized of the premises above conveyed; Calti has good, sure, perfect, absolute and indefeasible estate of inheritance, in law and in fee simple; and has good right, full power and lawful authority to grant, bargain, sell and convey the same in manner and form as aforesaid; and that the same are free and clear from all former and other grants, bargains, sales, liens, taxes, assessments, encumbrances and restrictions of whatever kind or nature soever, except taxes for 2016, not yet due and payable, and: 1. Right of way for ditches or canals constructed by the authority of the United States, as 6 described in the United States Patent dated dated August 21,1958, and recorded August 29;1958, in Book 185 at Page 69, as Reception No.1o6874. 2. Any and all notes, easements and recitals as disclosed on the recorded East Aspen Subdivision Plat recorded August 24,1959, in Ditch Book 2A at Page 252, as Reception No,108453. 3. Any and all notes, easements and recitals as disclosed on the recorded Boundary Agreement Plat recorded April 29,1982, in Book 13 at Page 35, as Reception No. 240935• 4. Terms, conditions, provisions, agreements and obligations specified under An Ordinance Designating a Portion of 17 Queen Street as H, Historic Landmark Pursuant to Division 7, Section 7- 701 of the Land Use Code, dated March 12, 19go, and recorded August 21, 19go, in Book 627 at Page 834, as Reception No. 325486• CITY OF ASPEN CITY OF ASPEN WRETT PAID HRETT PAID DATE REP NO.,51*31 DATE, 1llREP NO. 5Ma3 / RECEPTION#: 629520, 05/23/2016 at 10:55:33 AM, 2 OF 3, Janice K. Vos Caudill, Pitkin County, CO GENERAL. WARRANTY DEED Alice Brien to: 17 Queen LLC 5. Terms, conditions, provisions, agreements and obligations specified under the Covenant Burdening Real Property dated April 8, i99i, and recorded July 1, i99i, in Book 65o at Page 264, as Reception No. 334163. 6. Terms, conditions, provisions, agreements and obligations specified under An Ordinance of the City Council, of the City of Aspen, Colorado, Designating 17 Queen Street, a Metes and Bounds Parcel of Land being part of Tract 40, East Aspen Addition to the City of Aspen as "H", Historic Landmark Pursuant to Section 26.76.030 of the Aspen Municipal Code, dated January 13,1997, and recorded September 3,1997, as Reception No. 407978• 7. Any and all notes, easements and recitals as disclosed on the recorded Subdivision Exemption Plat for 114 Neale / 17 Queen Street Lot Split Plat recorded May 29,1998, in Plat Book 45 at Page 17, as Reception No. 417433• 8. Terms, conditions, provisions, agreements and obligations specified under An Ordinance of the Aspen City Council Granting Approval for a Subdivision Exemption for an Historic Landmark Lot Split at 114 Neale Avenue / 17 Queen Street (Parcel 1, of the Boundary Agreement Plat thereof recorded in Plat Book 13 at Page 35, City of Aspen, County of Pitkin, State of Colorado) Aspen, Colorado, and Declaring an Emergency in Accordance with Section 4.11 of the Aspen City Charter (Ordinance No.16 - Series of 1998), dated May 26,1998, and recorded February 18, 2000, as Reception No. 44o652. 9. Terms, conditions, provisions, agreements and obligations specified under the Resolution of the Aspen Historic Preservation Commission Approving an Application for Major Development (Final) for the New House Located at 114 Neale Street / 17 Queen Street, Historic Landmark Lot Split, Lot 2, City and Townsite of Aspen, Colorado (Resolution No.16 - Series of 2003, recorded July 24, 2003, as Reception No. 485909- 10. Terms, conditions, provisions, agreements and obligations specified under the Accessory Dwelling Unit Deed Restriction Pursuant to Section 26.520 of the City of Aspen Municipal Code, dated August 26, 2003, and recorded November 7, 2003, as Reception No. 49o883• 11. Terms, conditions, provisions, agreements and obligations specified under the Property Use License, recorded June 18, 2004, as Reception No. 4988o1. 12. Terms, conditions, provisions, agreements and obligations specified under A Resolution of the Aspen Historic Presrevation Commission (HPC) Approving an Application for Major Development (FINAL) and a Residential Design Standards Variance for 114 Neale Avenue, Lot 2 of the 114 Neale/17 Queen Street Historic Landmark Lot Split, City and Townsite of Aspen, Colorado (Resolution No. 5, Series of 2005) recorded February 25, 2005, as Reception No. 507358• 13. Fence lines do not correspond to the property boundary, as shown on the Improvement Survey Plat, provided by Peak Surveying, Inc., dated April 28, 2016, as Project No.16026. 14. Overhead utility lines traverse through the subject property, as shown on the Improvement Survey Plat, provided by Peak Surveying, Inc., dated April 28, 2os6, as Project No.16026. Page 2 of 3 RECEPTION#: 629520, 05/23/2016 at 10:55:33 AM, 3 OF 3, Janice K. Vos Caudill, Pitkin County, CO GENERAL, WARRANTY DEED Alice Brien to: 17 Queen LLC 15. Encroachment of Parcel 2's Concrete Driveway onto the southeast portion of the subject property, as shown on the Improvement Survey Plat, provided by Peak Surveying, Inc., dated April 28, 2oi6, as Project No. 16026. And the Grantor shall and will WARRANT AND FOREVER DEFEND the above described premises, in the quiet and peaceable possession of the Grantee and its succes rs arid,assigns of the Grantee, against all and every person or persons claiming the whole or atyy"p rt tWeof. IN WITNESS WHEREOF, the Grantor has executed this4eed,006 date set forth above. State of Colorado ) '� ) ss County of Pitkin ) The foregoing Warranty Deed, was executed and acknowledged before me on c 0Q May 2o16, by Alice Brien. Witness my hand and offici4l s al. a My commission expires: (p�apa� A_ Notary Public NICOLE EB Y NOTARY PUBLIC STATE OF COLORADO NOTARY M 20084004424 My COMMISSION EXPIRES fEB. e, 2020 Page 3 of 3 Leslie Miller Saiontz Exhibit E Exhibit F 7 9 1 0 OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE DYH WV WV WV D D D E G E G E I I O S W OSW X X X X X X D 2.0 ' 1 7 . 1 ' 21. 6 ' 4. 6 ' 10. 4 ' 1 6 . 6 ' 8.1 ' 0. 7 ' 5.3 ' 0. 7 ' 4.0 ' 1. 6 ' 27. 6 ' 1 9 . 8 ' 21. 2 ' 2 2 . 3 ' 21. 5 ' 4. 8 ' 9.2 ' 4. 6 ' 18. 4 ' 1 1 . 3 ' 8.2 ' 1. 5 ' 10. 3 ' 1 0 . 3 ' 1.6 ' 3. 7 ' 10. 5 ' 2 0 . 5 ' 14. 5 ' 2. 0 ' 7.2 ' 1 4 . 5 ' 2.0 ' 4. 2 ' 13. 1 ' 2 2 . 4 ' 13. 1 ' 7. 8 ' 9.6 ' 1 3 . 1 ' 9.6 ' 1. 5 ' 14. 5 ' 20. 3 ' 2 3 ' 10. 9 ' N 3 9 ° 1 4 ' 2 0 " E 96. 5 8 ' N 3 7 ° 2 6 ' 5 1 " E 62. 0 9 ' S 5 0 ° 2 0 ' 0 3 " E 8 4 . 4 9 ' S 3 0 ° 1 7 ' 0 0 " W 16 1 . 1 7 ' N 5 0 ° 0 7 ' 3 0 " W 1 0 7 . 6 4 ' BOULDER (TYP.) WIN D O W WEL L CONCRETE PATIO CONCRETE PATIO S T E P S STO N E W A L L ( T Y P . ) SPA UPPER LEVEL CONCRETE DECK W I N D O W W E L L BOULDER WALL (TYP.) BELOW ELEC. TRANS. TELE. PED. ELEC. METERS STORM DRAIN RIM 7901.64' INV 7898.14' BOTT 7887.75' #5 REBAR - TBM EL=7903.71' WATER SERVICE (TYP.) SIGN (TYP.) FIRE HYD. WATER VALVE (TYP.) STORM DRAIN (TYP.) CONCRETE DRIVEWAY FLAGSTONE WALK GAS METER GAS METER 0.40' STONE FASCIA (TYP.) 0.40' STONE FASCIA (TYP.) IRRIGATION CONTROL (TYP.) #4 REBAR #5 REBAR & CAP L.S. #25947 #5 REBAR & CAP L.S. #25947 F L A G S T O N E W A L K CO V E R E D FLA G S T O N E EN T R A N C E STU C C O W A L L CO N C R E T E W A L K WIN D O W WEL L BOULDER WALL (TYP.) Q U E E N S T R E E T R - O - W W I D T H V A R I E S A S P H A L T NE A L E A V E N U E R-O - W W I D T H V A R I E S ASP H A L T ASPH A L T DRIV E W A Y X X FENCE (TYP.) FENCE (TYP.) LOT 1 TIE R E T A I N I N G W A L L ACCES S E A S E M E N T P E R P L A T B K 1 3 P G 3 5 AND L I C E N S E P E R R E C . N O . 4 9 8 8 0 1 MAIL BOX MAIL BOX AD J O I N E R S H E D CON C R E T E DRIV E W A Y GRAVEL PARKING LOT 2 15,160 S.F.± 0.348 AC.± MULTI LEVEL WOOD & STONE FRAME HOUSE WITH BASEMENT 17 QUEEN STREET 110 NEALE AVENUE PARCEL 2 PLAT BK 13 PG 35 PARCEL 9 HERRON PARK PLAT BK 13 PG 35 SINGLE LEVEL WOOD & STONE FRAME ADU ELEC. OUTLET CO N C R E T E S I D E W A L K CO N C R E T E C U R B & G U T T E R FLAGSTONE WALK STONE WALL (TYP.) POWER POLE WATER FEATURE GRAVEL CONCRETE DRIVEWAY S S S S S S S S S S S S S S S S S S S S S S S S S S S S GASLINE SEWERLINE T T CO N C R E T E S I D E W A L K SIGN (TYP.) COMM. MANHOLES CONCRETE BOX INV EL=7896.20' IRRIGATION CONTROL GRAVEL PARKING PARCEL 2 PROJECT AREA 12' SEWERLINE EASEMENT PER BK 250 PG 477 & PLAT BK 13 PG 35 12' WATERLINE EASEMENT PER BK 340 PG 1 G G G G G G G G G G G G G G G G G G G G G G G G G G G G T T T T T T T T T T T T T T T T T T T T T T T E X - U E E X - U E EX - U E E X - U E E X - U E E X - U E E X - U E E X - U E E X - U E EX - U E EX - U E EX-UE E X - U E E X - U E T T T CT V CT V CTV CT V CT V CT V CT V CT V CT V CT V CT V C T V C T V C T V W W W W W W W W W W W W W E X - U E EX - U E EX - U E EX- U E EX-U E EX-UE EX-U E T T T G G G G WATERLINE GASLINE ELECTRIC CATV TE L E P H O N E OV E R H E A D E L E C T R I C T I E R E T A I N I N G W A L L UPP E R L E V E L W O O D D E C K BOULDER WALL (TYP.) BOULDER WALL (TYP.) IRR. CONTROL D D D F.F. 7914.6' RIDGE 7933.9' RIDGE 7936.0' CHIMNEY 7940.0' F.F. 7903.6' F.F. 7908.8' F.F. 7904.1' RIDGE 7918.4' W W W W W W W W W W W W STEEL POST T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T17 T18 T19 T20 T21 T22 T23 T24 T25 T26 T27 T28 T29 T30 T31 T32 T33 T34 T35 T36 T37 T38 T39 T40 T41 T42 T43 T44 T45 T46 T47 T48 T49 T50 T51 T52 T53 T54 T55 T56 T57 T58 T59 T60 T61 T62 T63 T64 T65 T66 T67 T68 T69 T70 T71 T72 T73 T74 T75T76 T77T78 STORM DRAIN RIM 7902.00' BOTT 7889.12' AREA DRAIN AREA DRAIN C.O.A. CONTROL Q-159 BEARS N77°07'51"W 1359.26' C.O.A. CONTROL #4 BEARS S32°07'00"W 387.54' 7 9 2 0 79 2 3 79 2 0 7 9 1 5 7 9 0 5 7 9 1 0 790 3 AREA SLOPE TABLE NUMBER 1 2 3 MIN. SLOPE 0.001% 20.000% 30.000% MAX. SLOPE 20.000% 30.000% + COLOR 10437.85 1975.24 2746.91 ByNO.Date Project NO.RevisionDrawn By: Checked By: Date: Computer File: P.O. Box 1746 Rifle, CO 81650 Phone (970) 625-1954 Fax (970) 579-7150 www.peaksurveyinginc.com S NW E P e a k Su r v ey i ng, Inc. Sinc e 2 0 0 7 16029B 1 OF 1 17 QUEEN, LLC CITY OF ASPEN, COLORADO IMPROVEMENT & TOPO SURVEY LOT 2, 114 NEALE/17QUEEN HISTORIC LOT SPLIT- 110 NEALE AVE. JRN JRN SEPT 27, 2018 029-IMPTOPO 1 10/19/18 UPDATE SLOPE TABLE JRN 2 10/22/18 UPDATE SLOPE TABLE JRN 3 05/12/20 UPDATE SURVEY JRN N E S W 0 30 60 90 120 150 180 210 240 270 300 330 P e a k S u r v e y i n g , I n c . 010 10 20 405 COL O R A D O L I CE N S E D P R O F E SSIONAL L A N D S U RVEYOR JAS O N R . N E I L 37935 IMPROVEMENT SURVEY PLAT & TOPOGRAPHIC SURVEY LOT 2, 114 NEALE/17QUEEN HISTORIC LOT SPLIT ACCORDING TO THE PLAT RECORDED MAY 29, 1998 IN PLAT BOOK 45 AT PAGE 17 CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO PROPERTY DESCRIPTION LOT 2, 114 NEALE/17QUEEN HISTORIC LOT SPLIT, ACCORDING TO THE PLAT RECORDED MAY 29, 1998 IN PLAT BOOK 45 AT PAGE 17, CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO. NOTES: 1) THIS PROPERTY IS SUBJECT TO RESERVATIONS, RESTRICTIONS, COVENANTS, BUILDING SETBACKS AND EASEMENTS OF RECORD, OR IN PLACE AND EXCEPTIONS TO TITLE SHOWN IN THE TITLE COMMITMENT PREPARED BY ATTORNEYS TITLE INSURANCE AGENCY OF ASPEN, LLC AND FIRST AMERICAN TITLE INSURANCE CO. INC. COMMITMENT NO. 16003515, DATED EFFECTIVE APRIL 20, 2016. 2) THE DATE OF THIS SURVEY WAS APRIL 27, 2016, SEPTEMBER 18, 2018 AND MAY 05, 2020. 3) BASIS OF BEARINGS FOR THIS SURVEY IS A BEARING OF S50°20'03"E BETWEEN THE NORTHWESTERLY CORNER OF LOT 2, A #5 REBAR & CAP L.S. #25947 FOUND IN PLACE AND THE NORTHEASTERLY CORNER OF LOT 2, A #5 REBAR & CAP L.S. #25947 FOUND IN PLACE. 4) UNITS OF MEASURE FOR ALL DIMENSIONS SHOWN HEREON IS U.S. SURVEY FEET. 5) THIS SURVEY IS BASED ON THE 114 NEALE/17QUEEN HISTORIC LOT SPLIT SUBDIVISION EXEMPTION PLAT RECORDED MAY 29, 1998 IN PLAT BOOK 45 AT PAGE 17 AND THE BOUNDARY AGREEMENT PLAT RECORDED APRIL 29, 1982 IN PLAT BOOK 13 AT PAGE 35 IN THE PITKIN COUNTY CLERK AND RECORDER'S OFFICE AND CORNERS FOUND IN PLACE. 6) BUILDING SETBACKS ACCORDING TO THE CITY OF ASPEN LAND USE CODE FOR R-15A 26.710.060 ARE AS FOLLOWS: FRONT YARD SETBACK RESIDENTIAL DWELLING = 25' ACCESSORY AND ALL OTHER BUILDINGS = 30' SIDE YARD SETBACK = 10' REAR YARD SETBACK RESIDENTIAL DWELLING = 10' ACCESSORY AND ALL OTHER BUILDINGS = 5' BUILDING SETBACKS SHOULD BE VERIFIED WITH THE CITY OF ASPEN PLANNING DEPARTMENT PRIOR TO ANY PLANNING OR CONSTRUCTION. 7) ELEVATIONS AS SHOWN ARE BASED ON A GPS OBSERVATION UTILIZING THE WESTERN COLORADO RTVRN GPS NETWORK (1988 ORTHO DATUM) YIELDING AN ONSITE ELEVATION OF 7903.71' ON THE SOUTHEASTERLY CORNER OF LOT 2. CONTOUR INTERVAL EQUALS 1 FOOT. 8) ACCORDING TO FEMA PANEL NO. 08097C0204C, DATED JUNE 04, 1987 THE SUBJECT PROPERTY IN NOT WITHIN THE 100 YEAR FLOODPLAIN. 9) AT THE TIME OF THE MAY 05, 2020 FIELD VISIT MISC. EXTERIOR WORK WAS BEING PERFORMED AND TEMPORARY CONSTRUCTION FENCES EXISTED. NO R T H VICINITY MAP SCALE: 1" = 2000' SUBJECT PROPERTY IMPROVEMENT SURVEY STATEMENT I, JASON R. NEIL, HEREBY CERTIFY TO 17 QUEEN LLC, A COLORADO LIMITED LIABILITY COMPANY, THAT I AM A PROFESSIONAL LAND SURVEYOR LICENSED UNDER THE LAWS OF THE STATE OF COLORADO; THAT THIS IMPROVEMENT SURVEY PLAT IS TRUE, CORRECT AND COMPLETE BASED ON MY KNOWLEDGE, INFORMATION AND BELIEF AS LAID OUT AND SHOWN HEREON; THAT THIS IMPROVEMENT SURVEY PLAT IS NOT A GUARANTY OR WARRANTY, EITHER EXPRESSED OR IMPLIED, THAT THIS IMPROVEMENT SURVEY PLAT WAS MADE BY ME FROM AN ACCURATE SURVEY OF THE REAL PROPERTY PERFORMED BY ME OR UNDER MY DIRECT SUPERVISION ON APRIL 27, 2016, SEPTEMBER 18, 2018 AND MAY 05, 2020; THAT, IN THE PREPARATION OF THIS IMPROVEMENT SURVEY PLAT, I RELIED UPON THE TITLE COMMITMENT PREPARED BY ATTORNEYS TITLE INSURANCE AGENCY OF ASPEN, LLC AND FIRST AMERICAN TITLE INSURANCE CO. INC. COMMITMENT NO. 16003515, DATED EFFECTIVE APRIL 20, 2016; THAT THE LOCATION AND DIMENSIONS OF ALL BUILDINGS, IMPROVEMENTS, EASEMENTS, RIGHTS OF WAY IN EVIDENCE OR KNOWN TO ME AND ENCROACHMENTS BY OR ON THE REAL PROPERTY AND MATTERS REFERENCED IN SAID TITLE COMMITMENT CAPABLE OF BEING SHOWN ARE ACCURATELY SHOWN, AND THAT THIS PLAT IS IN ACCORDANCE OF AN IMPROVEMENT SURVEY PLAT AS SET FORTH IN C.R.S. §38-51-102(9). DATED: MAY 12, 2020 BY:___________________________________ JASON R. NEIL, P.L.S. NO. 37935 FOR AND ON BEHALF OF PEAK SURVEYING, INC. 25'-0" FRONT YARD SETBACK 10'-0" SIDE YARD SETBACK 10' REAR YARD SETBACK 1 0 ' - 0 " S I D E Y A R D S E T B A C K EXISTING PAVED DRIVEWAY AND PARKING AREA TO BE RECONFIGURED EXISTING PATIO AND RETAINING WALLS TO BE REMOVED EXISTING PATIO TO BE REMOVED AND ENCLOSED EXISTING FRONT PORCH TO BE REMOVED AND REPLACED EXISTING ROOF DECK EXISTING ROOF DECK EXISTING FLAGSTONE WALK TO BE REFINISHED ACCESS EASEMENT TO ADJACENT PARCEL TRANSFORMER AND ELECTRICAL PANEL TERRACED PLANTING WALLS TO BE REVISED BY LANDSCAPE ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN EXISTING SIDEWALK ENDS AT CORNER OF NEALE AVE AND QUEEN ST TREES IN ZONE TO BE REMOVED DUE TO ENGINEERING REQUIREMENTS SHED ON ADJACENT PROPERTY ENCROACHES INTO SETBACK EXISTING FENCE TO REMAIN EDGE OF PAVED DRIVEWAY SERVING ADJACENT PARCEL 7901' 7902' 7903' 7 9 0 4 '7 9 0 5 '7 9 0 6 '7 9 0 7 '7 9 0 8' 7 9 0 9 ' 7 9 1 0 ' 7 9 1 1 ' 7 9 1 2 ' 7 9 1 3 '7 9 1 4 '7 9 1 5 ' 7 9 1 7 ' 7 9 1 8 ' 7 9 1 9 ' 7920' 7 9 2 2 ' 7 9 2 3 ' 7 9 2 4 ' 7 9 1 6 ' 7901' 7904' 7904' 7 9 2 1 ' PROPERTY LINE SIDE YARD SETBACK NEALE AVENUE EXISTING SIDEWALK TO REMAIN S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE PROPERTY LINE P R O P E R T Y L I N E 7903' 7904' 7905' 7906' 7907' 7908' 7909' 7910' 7921' 7911' 7 9 1 2 ' 7 9 1 3 ' QUEEN STREET EXISTING ADU TO BE REPLACED BY NEW GARAGE SOME WALLS TO REMAIN EXISTING CONIFEROUS TREE TO BE REMOVED EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN NEW DECIDUOUS TREE NEW CONIFEROUS TREE SITE PLAN LEGEND EXISTING 1' CONTOUR PROPOSED 1' CONTOUR EXISTING 5' CONTOUR PROPOSED 5' CONTOUR TOPOGRAPHY LEGEND N SCALE: 1:901EXISTING SITE PLAN AT MAIN LEVEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-001X EXISTING SITE PLAN AT MAIN LEVEL 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL 1 0 ' - 0 " S I D E Y A R D S E T B A C K 10'-0" SIDE YARD SETBACK 10' REAR YARD SETBACK 25'-0" FRONT YARD SETBACK T.O. RIDGE (VIF) 122'-23/4" T.O. RIDGE (VIF) 119'-93/4" T.O. RIDGE (VIF) 118'-51/2" EXISTING FLAGSTONE WALK TO BE REFINISHED ACCESS EASEMENT TO ADJACENT PARCEL EXISTING TRANSFORMER AND ELECTRICAL PANEL TO REMAIN TERRACED PLANTING WALLS TO BE REVISED BY LANDSCAPE ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN EXISTING FENCE AT 114 NEALE AVE EDGE OF PAVED DRIVEWAY SERVING ADJACENT PARCEL EXISTING PAVED DRIVEWAY AND PARKING AREA TO BE RECONFIGURED EXISTING PATIO TO BE REMOVED AND ENCLOSED EXISTING FRONT PORCH TO BE REMOVED AND REPLACED EXISTING ROOF DECK EXISTING ROOF DECK TREES IN ZONE TO BE REMOVED DUE TO ENGINEERING REQUIREMENTS. TREES TO REMAIN WHERE POSSIBLE. SHED ON ADJACENT PROPERTY ENCROACHES INTO SETBACK EXISTING PATIO AND RETAINING WALLS TO BE REMOVED EXISTING DRYWELL TO REMAIN EXISTING DRYWELL TO REMAIN EXISTING DRYWELL TO REMAINEXISTING DRYWELLS TO REMAIN ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN TREES IN ZONE TO BE REMOVED DUE TO ENGINEERING REQUIREMENTS. TREES TO REMAIN WHERE POSSIBLE. PROPERTY LINE SIDE YARD SETBACK NEALE AVENUE EXISTING SIDEWALK NO PROPOSED CHANGES, TO BE COORDINATED WITH COA S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE PROPERTY LINE P R O P E R T Y L I N E QUEEN STREET 7901' 7902' 7903' 7 9 0 4 '7 9 0 5 '7 9 0 6 '7 9 0 7 '7 9 0 8' 7 9 0 9 ' 7 9 1 0 ' 7 9 1 1 ' 7 9 1 2 ' 7 9 1 3 '7 9 1 4 '7 9 1 5 ' 7 9 1 7 ' 7 9 1 8 ' 7 9 1 9 ' 7920' 7 9 2 2 ' 7 9 2 3 ' 7 9 2 4 ' 7 9 1 6 ' 7901' 7904' 7904' 7 9 2 1 ' 7903' 7904' 7905' 7906' 7907' 7908' 7909' 7910' 7921' 7911' 7 9 1 2 ' 7 9 1 3 ' 7904' 7904' T.O. RIDGE (VIF) 118'-51/2" T.O. STONE CAP (VIF) 123'-1" T.O. STONE CAP (VIF) 125'-5" T.O. RIDGE (VIF) 119'-93/4" EXISTING ADU TO BE REPLACED BY NEW GARAGE SOME WALLS TO REMAIN EXISTING CONIFEROUS TREE TO BE REMOVED EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN NEW DECIDUOUS TREE NEW CONIFEROUS TREE SITE PLAN LEGEND EXISTING 1' CONTOUR PROPOSED 1' CONTOUR EXISTING 5' CONTOUR PROPOSED 5' CONTOUR TOPOGRAPHY LEGEND PROPOSED STANDING SEAM ROOF EXISTING STRUCTURE TO BE REFINISHED WITH SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE EXISTING SHAKE ROOF TO BE REFINISHED EXISTING STRUCTURE TO BE REFINISHED WITH STANDING SEAM METAL ROOF MATERIAL LEGEND PROPOSED SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE N SCALE: 1:901EXISTING SITE PLAN AT ROOF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-002X EXISTING SITE PLAN AT ROOF 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL EXISTING CONIFEROUS TREE TO BE REMOVED EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN NEW DECIDUOUS TREE NEW CONIFEROUS TREE SITE PLAN LEGEND EXISTING 1' CONTOUR PROPOSED 1' CONTOUR EXISTING 5' CONTOUR PROPOSED 5' CONTOUR TOPOGRAPHY LEGEND 25'-0" FRONT YARD SETBACK 10' REAR YARD SETBACK 1 0 ' - 0 " S I D E Y A R D S E T B A C K 10'-0" SIDE YARD SETBACK T.O. ENTRY PORCH 94'-33/4" T.O. DECK 100'-3" T.O. WALL 102'-3" T.O. WALL 102'-11" T.O. WALL 103'-11" T.O. WALL 103'-11" T.O. DECK 100'-3" T.O. PATIO 99'-9" T.O. PATIO 100'-3" EXISTING FLAGSTONE WALK TO BE REFINISHED ACCESS EASEMENT TO ADJACENT PARCEL TRANSFORMER AND ELECTRICAL PANEL SHED ON ADJACENT PROPERTY ENCROACHES INTO SETBACK TERRACED PLANTING WALLS TO BE REVISED BY LANDSCAPE ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN PROPOSED EXTENSION OF SIDEWALK ALONG QUEEN STREET, TO BE COORDINATED WITH CITY OF ASPEN ENGINEERING DEPT STONE PLANTER WITHIN 30" OF GRADE IN SETBACK STONE PLANTER WITHIN 30" OF GRADE IN SETBACK PROPOSED LANDSCAPE TREADS EXISTING FENCE TO REMAIN 4343 4343 43 43 43 EDGE OF PAVED DRIVEWAY SERVING ADJACENT PARCEL 32 LINE OF SHADE STRUCTURE ABOVE 4343 4343 43 43 32 32 7901' 7902' 7903' 7 9 0 4 '7 9 0 5 '7 9 0 6 '7 9 0 7 '7 9 0 8' 7 9 0 9 ' 7 9 1 0 ' 7 9 1 1 ' 7 9 1 2 ' 7 9 1 3 '7 9 1 4 '7 9 1 5 ' 7 9 1 7 ' 7 9 1 8 ' 7 9 1 9 ' 7920' 7 9 2 2 ' 7 9 2 3 ' 7 9 2 4 ' 7 9 1 6 ' 7901' 7904' 7904' 7 9 2 1 ' PROPERTY LINE SIDE YARD SETBACK NEALE AVENUE EXISTING SIDEWALK TO REMAIN S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE PROPERTY LINE P R O P E R T Y L I N E 7903' 7904' 7905' 7906' 7907' 7908' 7909' 7910' 7921' 7911' 7 9 1 2 ' 7 9 1 3 ' 110 NEALE AVENUE ASPEN, CO 81611 PARCEL ID: 273707383002 PROJECT 100' = 7914.35' PROPOSED MASTER BEDROOM PATIO PROPOSED ROOF DECK UNDER TRELLIS RECONFIGURED DRIVEWAY AND PARKING AREA PROPOSED ROOF DECK 110 NEALE AVENUE ASPEN, CO 81611 PARCEL ID: 273707383002 PROJECT 100' = 7914.35' QUEEN STREET PROPOSED PATIO AND MOVABLE OUTDOOR KITCHEN NEW FRONT PORCH EXISTING CONIFEROUS TREE TO BE REMOVED EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN NEW DECIDUOUS TREE NEW CONIFEROUS TREE SITE PLAN LEGEND EXISTING 1' CONTOUR PROPOSED 1' CONTOUR EXISTING 5' CONTOUR PROPOSED 5' CONTOUR TOPOGRAPHY LEGEND N SCALE: 1:901PROPOSED SITE PLAN AT MAIN LEVEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-001 PROPOSED SITE PLAN AT MAIN LEVEL 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL 10' REAR YARD SETBACK 1 0 ' - 0 " S I D E Y A R D S E T B A C K 10'-0" SIDE YARD SETBACK 25'-0" FRONT YARD SETBACK T.O. RIDGE 122'-23/4" T.O. RIDGE 119'-93/4" T.O. RIDGE 118'-51/2" T.O. RIDGE (VIF) 118'-51/2" T.O. PORCH ROOF AT EDGE 101'-73/4" T.O. AUTOCOURT PORCH ROOF AT EDGE 98'-11"T.O. RIDGE 116'-31/4" EXISTING FLAGSTONE WALK TO BE REFINISHED ACCESS EASEMENT TO ADJACENT PARCEL EXISTING TRANSFORMER AND ELECTRICAL PANEL TO REMAIN TERRACED PLANTING WALLS TO BE REVISED BY LANDSCAPE ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN PROPOSED EXTENSION OF SIDEWALK ALONG QUEEN STREET, TO BE COORDINATED WITH CITY OF ASPEN ENGINEERING DEPT. STREET PARKING TO BE MAINTAINED STONE PLANTER WITHIN 30" OF GRADE IN SETBACK STONE PLANTER WITHIN 30" OF GRADE IN SETBACK EXISTING FENCE AT 114 NEALE AVE EDGE OF PAVED DRIVEWAY SERVING ADJACENT PARCEL EXISTING DRYWELL TO REMAIN EXISTING DRYWELL TO REMAIN EXISTING DRYWELL TO REMAINEXISTING DRYWELLS TO REMAIN ZONE OF HEAVY PLANTING, UNDERSTORY TO BE REVISED, TREES TO REMAIN PROPERTY LINE SIDE YARD SETBACK NEALE AVENUE EXISTING SIDEWALK NO PROPOSED CHANGES, TO BE COORDINATED WITH COA S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE PROPERTY LINE P R O P E R T Y L I N E PROPOSED MASTER BEDROOM PATIO PROPOSED ROOF DECK UNDER PERGOLA RECONFIGURED DRIVEWAY AND PARKING AREA PROPOSED ROOF DECK QUEEN STREET 7901' 7902' 7903' 7 9 0 4 '7 9 0 5 '7 9 0 6 '7 9 0 7 '7 9 0 8' 7 9 0 9 ' 7 9 1 0 ' 7 9 1 1 ' 7 9 1 2 ' 7 9 1 3 '7 9 1 4 '7 9 1 5 ' 7 9 1 7 ' 7 9 1 8 ' 7 9 1 9 ' 7920' 7 9 2 2 ' 7 9 2 3 ' 7 9 2 4 ' 7 9 1 6 ' 7901' 7904' 7904' 7 9 2 1 ' 7903' 7904' 7905' 7906' 7907' 7908' 7909' 7910' 7921' 7911' 7 9 1 2 ' 7 9 1 3 ' 7904' 7904' T.O. RIDGE 119'-93/4" T.O. RIDGE 118'-51/2" LINE OF PERGOLA PROPOSED PATIO AND MOVABLE OUTDOOR KITCHEN PROPOSED FRONT PORCH ROOF 110 NEALE AVENUE ASPEN, CO 81611 PARCEL ID: 273707383002 PROJECT 100' = 7914.35' T.O. STONE CAP 113'-11/4" T.O. STONE CAP (VIF) 123'-1" T.O. STONE CAP (VIF) 125'-5" EXISTING CONIFEROUS TREE TO BE REMOVED EXISTING DECIDUOUS TREE TO BE REMOVED EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN NEW DECIDUOUS TREE NEW CONIFEROUS TREE SITE PLAN LEGEND EXISTING 1' CONTOUR PROPOSED 1' CONTOUR EXISTING 5' CONTOUR PROPOSED 5' CONTOUR TOPOGRAPHY LEGEND PROPOSED STANDING SEAM ROOF EXISTING STRUCTURE TO BE REFINISHED WITH SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE EXISTING SHAKE ROOF TO BE REFINISHED EXISTING STRUCTURE TO BE REFINISHED WITH STANDING SEAM METAL ROOF MATERIAL LEGEND PROPOSED SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE N SCALE: 1:901PROPOSED SITE PLAN AT ROOF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-002 PROPOSED SITE PLAN AT ROOF 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-006 BASEMENT WALL DEMOLITION CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 192.00 sq ft 66.50 sq ft 126.00 sq ft 123.75 sq ft 21.75 sq ft 154.75 sq ft 189.75 sq ft 38.50 sq ft 164.50 sq ft 15.75 sq ft 118.50 sq ft 209.00 sq ft 205.75 sq ft 211.50 sq ft 219.75 sq ft 77.75 sq ft 52.00 sq ft 16.50 sq ft 51.00 sq ft 25.75 sq ft 25.75 sq ft 6.25 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 62.50 sq ft 19.75 sq ft 7.00 sq ft 7.75 sq ft 8.25 sq ft 8.25 sq ft 8.25 sq ft 8.75 sq ft 25.75 sq ft 16.75 sq ft 13.75 sq ft 13.75 sq ft 33.50 sq ft 28.00 sq ft 29.25 sq ft 35.25 sq ft 22.25 sq ft 22.25 sq ft 22.25 sq ft 7.75 sq ft 72.75 sq ft 72.75 sq ft 22.50 sq ft 22.50 sq ft 22.50 sq ft 22.50 sq ft 15.25 sq ft 15.25 sq ft 28.75 sq ft 14.25 sq ft 29.50 sq ft 13.75 sq ft 7.50 sq ft 9.00 sq ft 23.50 sq ft 20.75 sq ft 26.25 sq ft 16.25 sq ft16.25 sq ft 26.25 sq ft 72.50 sq ft 22.25 sq ft 43.25 sq ft 61.00 sq ft 29.50 sq ft 120.00 sq ft170.00 sq ft 388.50 sq ft 197.75 sq ft 114.25 sq ft 183.00 sq ft 16.25 sq ft 87.25 sq ft 12.25 sq ft 31.25 sq ft 12.00 sq ft 150.75 sq ft 182.00 sq ft 83.50 sq ft 180.00 sq ft 130.50 sq ft 118.75 sq ft 64.25 sq ft 162.75 sq ft 152.50 sq ft 18.25 sq ft 96.75 sq ft 12.75 sq ft 29.75 sq ft 93.75 sq ft 89.00 sq ft 106.75 sq ft 59.75 sq ft 81.25 sq ft 101.00 sq ft 8.00 sq ft 64.00 sq ft 38.25 sq ft 59.75 sq ft 22.75 sq ft 145.25 sq ft W1 W2 W3 W11 W12 W13 W14 W15 W16 W17 W18 W19 W20 W21 W22 W23 W24 W25 W26 W27 W28 W29 W30 W31 W4 W5 W6 W7 W8 W9 W10 W32 W34 W35 W36 W37 W39W38W33 W40 AW1 AW2 AW3 AW4 AW5 AW6 AW7 AW8 205.75 sq ft 24.00 sq ft 6.50 sq ft 9.00 sq ft 48.75 sq ft 9.00 sq ft 7.75 sq ft 76.75 sq ft 26.25 sq ft 26.25 sq ft 9.25 sq ft 25.50 sq ft 13.50 sq ft 22.25 sq ft 15.50 sq ft15.50 sq ft 10.50 sq ft 9.00 sq ft 207.75 sq ft EXISTING TO REMAIN TO BE DEMOLISHED AREA REDUCED FOR FENSTRATION DEMO CALC FILL LEGEND EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 9 9 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% 0 4'8'16'SCALE: 1/8" = 1'-0"2 WALL DEMO AREA 0 4'8'16'SCALE: 1/8" = 1'-0"1 BASEMENT LEVEL DEMO PLAN NO COUNTABLE WALL DEMO AREA AT BASEMENT LEVEL COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-007 GARAGE (MIDDLE) LEVEL WALL DEMOLITION CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 192.00 sq ft 66.50 sq ft 126.00 sq ft 123.75 sq ft 21.75 sq ft 154.75 sq ft 189.75 sq ft 38.50 sq ft 164.50 sq ft 15.75 sq ft 118.50 sq ft 209.00 sq ft 205.75 sq ft 211.50 sq ft 219.75 sq ft 77.75 sq ft 52.00 sq ft 16.50 sq ft 51.00 sq ft 25.75 sq ft 25.75 sq ft 6.25 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 62.50 sq ft 19.75 sq ft 7.00 sq ft 7.75 sq ft 8.25 sq ft 8.25 sq ft 8.25 sq ft 8.75 sq ft 25.75 sq ft 16.75 sq ft 13.75 sq ft 13.75 sq ft 33.50 sq ft 28.00 sq ft 29.25 sq ft 35.25 sq ft 22.25 sq ft 22.25 sq ft 22.25 sq ft 7.75 sq ft 72.75 sq ft 72.75 sq ft 22.50 sq ft 22.50 sq ft 22.50 sq ft 22.50 sq ft 15.25 sq ft 15.25 sq ft 28.75 sq ft 14.25 sq ft 29.50 sq ft 13.75 sq ft 7.50 sq ft 9.00 sq ft 23.50 sq ft 20.75 sq ft 26.25 sq ft 16.25 sq ft16.25 sq ft 26.25 sq ft 72.50 sq ft 22.25 sq ft 43.25 sq ft 61.00 sq ft 29.50 sq ft 120.00 sq ft170.00 sq ft 388.50 sq ft 197.75 sq ft 114.25 sq ft 183.00 sq ft 16.25 sq ft 87.25 sq ft 12.25 sq ft 31.25 sq ft 12.00 sq ft 150.75 sq ft 182.00 sq ft 83.50 sq ft 180.00 sq ft 130.50 sq ft 118.75 sq ft 64.25 sq ft 162.75 sq ft 152.50 sq ft 18.25 sq ft 96.75 sq ft 12.75 sq ft 29.75 sq ft 93.75 sq ft 89.00 sq ft 106.75 sq ft 59.75 sq ft 81.25 sq ft 101.00 sq ft 8.00 sq ft 64.00 sq ft 38.25 sq ft 59.75 sq ft 22.75 sq ft 145.25 sq ft W1 W2 W3 W11 W12 W13 W14 W15 W16 W17 W18 W19 W20 W21 W22 W23 W24 W25 W26 W27 W28 W29 W30 W31 W4 W5 W6 W7 W8 W9 W10 W32 W34 W35 W36 W37 W39W38W33 W40 AW1 AW2 AW3 AW4 AW5 AW6 AW7 AW8 205.75 sq ft 24.00 sq ft 6.50 sq ft 9.00 sq ft 48.75 sq ft 9.00 sq ft 7.75 sq ft 76.75 sq ft 26.25 sq ft 26.25 sq ft 9.25 sq ft 25.50 sq ft 13.50 sq ft 22.25 sq ft 15.50 sq ft15.50 sq ft 10.50 sq ft 9.00 sq ft 207.75 sq ft EXISTING TO REMAIN TO BE DEMOLISHED AREA REDUCED FOR FENSTRATION DEMO CALC FILL LEGEND EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND W1 W2 W3 AW2 W40 W39 W38 W37 W36 W34 AW4 AW3 AW1 AW8 AW5 AW6 AW7 9 9 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% 0 4'8'16'SCALE: 1/8" = 1'-0"2 WALL DEMO AREA 0 4'8'16'SCALE: 1/8" = 1'-0"1 GARAGE (MIDDLE) LEVEL DEMO PLAN COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-008 MAIN LEVEL WALL DEMOLITION CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 192.00 sq ft 66.50 sq ft 126.00 sq ft 123.75 sq ft 21.75 sq ft 154.75 sq ft 189.75 sq ft 38.50 sq ft 164.50 sq ft 15.75 sq ft 118.50 sq ft 209.00 sq ft 205.75 sq ft 211.50 sq ft 219.75 sq ft 77.75 sq ft 52.00 sq ft 16.50 sq ft 51.00 sq ft 25.75 sq ft 25.75 sq ft 6.25 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 15.00 sq ft 62.50 sq ft 19.75 sq ft 7.00 sq ft 7.75 sq ft 8.25 sq ft 8.25 sq ft 8.25 sq ft 8.75 sq ft 25.75 sq ft 16.75 sq ft 13.75 sq ft 13.75 sq ft 33.50 sq ft 28.00 sq ft 29.25 sq ft 35.25 sq ft 22.25 sq ft 22.25 sq ft 22.25 sq ft 7.75 sq ft 72.75 sq ft 72.75 sq ft 22.50 sq ft 22.50 sq ft 22.50 sq ft 22.50 sq ft 15.25 sq ft 15.25 sq ft 28.75 sq ft 14.25 sq ft 29.50 sq ft 13.75 sq ft 7.50 sq ft 9.00 sq ft 23.50 sq ft 20.75 sq ft 26.25 sq ft 16.25 sq ft16.25 sq ft 26.25 sq ft 72.50 sq ft 22.25 sq ft 43.25 sq ft 61.00 sq ft 29.50 sq ft 120.00 sq ft170.00 sq ft 388.50 sq ft 197.75 sq ft 114.25 sq ft 183.00 sq ft 16.25 sq ft 87.25 sq ft 12.25 sq ft 31.25 sq ft 12.00 sq ft 150.75 sq ft 182.00 sq ft 83.50 sq ft 180.00 sq ft 130.50 sq ft 118.75 sq ft 64.25 sq ft 162.75 sq ft 152.50 sq ft 18.25 sq ft 96.75 sq ft 12.75 sq ft 29.75 sq ft 93.75 sq ft 89.00 sq ft 106.75 sq ft 59.75 sq ft 81.25 sq ft 101.00 sq ft 8.00 sq ft 64.00 sq ft 38.25 sq ft 59.75 sq ft 22.75 sq ft 145.25 sq ft W1 W2 W3 W11 W12 W13 W14 W15 W16 W17 W18 W19 W20 W21 W22 W23 W24 W25 W26 W27 W28 W29 W30 W31 W4 W5 W6 W7 W8 W9 W10 W32 W34 W35 W36 W37 W39W38W33 W40 AW1 AW2 AW3 AW4 AW5 AW6 AW7 AW8 205.75 sq ft 24.00 sq ft 6.50 sq ft 9.00 sq ft 48.75 sq ft 9.00 sq ft 7.75 sq ft 76.75 sq ft 26.25 sq ft 26.25 sq ft 9.25 sq ft 25.50 sq ft 13.50 sq ft 22.25 sq ft 15.50 sq ft15.50 sq ft 10.50 sq ft 9.00 sq ft 207.75 sq ft EXISTING TO REMAIN TO BE DEMOLISHED AREA REDUCED FOR FENSTRATION DEMO CALC FILL LEGEND EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND W1 W2 W3W4 W5 W6 W7 W8 W9 W10 W11 W12 W13 W14 W15 W16 W17 W18 W19 W20 W21 W22 W23 W24 W25 W26 W27 W28 W29 W30 W31 W32 9 9 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I RXX RXX RXX RXX RXX RXX Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% 0 4'8'16'SCALE: 1/8" = 1'-0"2 WALL DEMO AREA 0 4'8'16'SCALE: 1/8" = 1'-0"1 MAIN LEVEL DEMO PLAN COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-009 ROOF DEMOLITION CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 68.00 sq ft 18.25 sq ft18.25 sq ft 98.00 sq ft 29.75 sq ft 58.25 sq ft 78.00 sq ft 77.25 sq ft 225.00 sq ft 101.25 sq ft 23.50 sq ft 23.50 sq ft 214.50 sq ft 590.00 sq ft 289.00 sq ft 630.00 sq ft 139.00 sq ft 44.50 sq ft 554.50 sq ft 71.75 sq ft 88.00 sq ft 220.25 sq ft 42.25 sq ft42.25 sq ft 178.00 sq ft 306.00 sq ft 176.25 sq ft 79.50 sq ft 85.75 sq ft 54.50 sq ft 88.50 sq ft 53.00 sq ft 113.00 sq ft 134.50 sq ft 170.25 sq ft 255.00 sq ft 18.50 sq ft 61.00 sq ft 61.75 sq ft 19.50 sq ft 219.50 sq ft39.75 sq ft 4.25 sq ft 105.50 sq ft105.50 sq ft R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R15 R14 R16 R17 R18 R20 R21 R19 R22 R23 R25 R24 R26 R27 R28 R29 R30 R32 AR1 AR2 AR3 AR4 AR5 R33 R34 R31 R35 54.50 sq ft 20.75 sq ft EXISTING TO REMAIN TO BE DEMOLISHED AREA REDUCED FOR FENSTRATION DEMO CALC FILL LEGEND EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND R26 R27 R29 R28 R30 R33 R35 R34 R25R21 R20 R22 R24 R19 R18 R17 R15 R14 R13 R11 R12 R16 R9 R5 R4 9 9 R6 R7 R8 R10 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I R31 R32 AR1 AR2 AR3 AR4 AR5R23 R3 R2 R1 Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% Existing Demolition Calculations - Walls Existing Demolition Calculations - Roof 110 Neale Ave 110 Neale Ave Demolition Demolition Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft)Wall/Roof Label Individual Area (Sq Ft) Area Reduced for Fenestration (Sq Ft) Area to be Removed (Sq Ft) AW1 81.25 25.50 55.75 AR1 255.00 0.00 255.00 AW2 66.50 13.75 52.75 AR2 170.25 0.00 170.25 AW3 133.00 27.75 0.00 AR3 134.50 0.00 134.50 AW4 179.00 6.75 0.00 AR4 113.00 0.00 113.00 AW5 101.00 0.00 0.00 AR5 53.00 0.00 53.00 AW6 8.00 0.00 8.00 AW7 64.00 0.00 64.00 R1 88.50 0.00 0.00 AW8 126.00 9.00 70.00 R2 85.75 0.00 0.00 R3 54.50 0.00 0.00 W1 388.50 91.50 157.50 R4 79.50 0.00 0.00 W2 197.75 0.00 51.50 R5 176.25 0.00 0.00 W3 114.25 19.75 38.25 R6 178.00 0.00 4.25 W4 18.25 0.00 18.25 R7 220.25 0.00 0.00 W5 123.75 45.00 21.75 R8 42.25 0.00 0.00 W6 96.75 45.00 51.75 R9 306.00 0.00 147.75 W7 12.75 0.00 12.75 R10 42.25 0.00 0.00 W8 29.75 0.00 29.75 R11 71.75 0.00 71.75 W9 93.75 62.50 31.25 R12 88.00 0.00 0.00 W10 237.25 6.50 22.25 R13 61.00 0.00 61.00 W11 214.50 19.75 0.00 R14 61.75 0.00 61.75 W12 47.25 0.00 0.00 R15 18.50 0.00 18.50 W13 59.75 7.00 0.00 R16 139.00 0.00 39.75 W14 87.25 7.75 0.00 R17 19.50 0.00 19.50 W15 12.25 0.00 0.00 R18 44.50 0.00 44.50 W16 31.25 0.00 0.00 R19 554.50 0.00 219.50 W17 12.00 0.00 0.00 R20 18.25 0.00 18.25 W18 164.25 24.75 0.00 R21 630.00 0.00 160.00 W19 205.75 66.75 22.25 R22 68.00 0.00 68.00 W20 89.00 0.00 0.00 R23 289.00 0.00 0.00 W21 106.75 34.50 0.00 R24 18.25 0.00 18.25 W22 150.75 16.75 0.00 R25 590.00 0.00 105.50 W23 182.00 27.50 0.00 R26 225.00 0.00 0.00 W24 83.50 33.50 0.00 R27 214.50 0.00 0.00 W25 180.00 170.00 0.00 R28 98.00 0.00 0.00 W26 130.50 120.00 0.00 R29 101.25 0.00 0.00 W27 178.50 0.00 0.00 R30 29.75 0.00 0.00 W28 87.00 0.00 0.00 R31 23.50 0.00 0.00 W29 145.25 66.75 61.00 R32 23.50 0.00 0.00 W30 207.75 107.50 63.25 R33 58.25 0.00 0.00 W31 162.75 90.00 0.00 R34 76.50 0.00 48.75 W32 152.50 14.25 44.25 R35 78.00 0.00 78.00 W33 15.75 0.00 0.00 Wall Surface Area Total (Sq Ft)5,599.25 W34 118.50 0.00 0.00 Area Reduced for Fenestration (Sq Ft)0.00 W35 209.00 92.50 0.00 Wall Surface Area to be Removed (Sq Ft)1,910.75 W36 205.75 15.50 190.25 W37 211.50 145.50 66.00 W38 219.75 59.25 160.50 W39 52.00 29.50 22.50 W40 77.75 9.25 43.25 Wall Surface Area Total (Sq Ft)5,872.00 Area Reduced for Fenestration (Sq Ft)1511.25 Wall Surface Area to be Removed (Sq Ft)1,358.75 Demolition Totals Roof + Wall Area Used for Demo Calculation (Sq Ft)9,960.00 Surface Area to be Removed (Sq Ft)3,269.50 Total 32.83% 0 4'8'16'SCALE: 1/8" = 1'-0"2 WALL DEMO AREA 0 4'8'16'SCALE: 1/8" = 1'-0"1 ROOF LEVEL DEMO PLAN COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-010X FLOOR AREA CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 85.25 sq ft 63.00 sq ft 27.75 sq ft 153.75 sq ft 100.50 sq ft 80.00 sq ft 8.25 sq ft 66.00 sq ft 389.25 sq ft 249.50 sq ft 418.00 sq ft 80.00 sq ft 144.50 sq ft 9.50 sq ft 39.50 sq ft XB1 XB2 XB3 XB4 XB5 XB6 XB9 XB10 XB11 XB7 XB8 XB12 COUNTABLE FAR PLAN LEGEND DECK GARAGE EXEMPT - T.O. CIRCULATION OR OPEN TO BELOW EXEMPT - FRONT PORCH EXEMPT - ON-GRADE PATIO 2,064.75 sq ft XB1 XB2 XB3 XB12 XB11 XB6 XB4 XB5 CRAWL SPACE 9 9 XB10 XB9 XB8 XB7 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 110 Neale Avenue Existing Basement Level Floor Area Basement Level Floor Area without Exemptions (Sq Ft)2,064.75 Existing Lower Level Floor Area Lower Level Floor Area without Exemptions (Sq Ft)2,347.00 Lower Level Exempt (OTB / T.O. Circ)0.00 Garage Floor Area without Exemptions (Sq Ft)483.00 Existing Main Level Floor Area Main Level Floor Area without Exemptions (Sq Ft)2,756.50 Main Level Exempt (T.O. Circ)110.25 Front Portch (Exempt)66.00 Main Level Deck Floor Area without Exemptions (Sq Ft)780.50 Existing "ADU" Floor Area ADU Gross Floor Area (Sq Ft)405.50 Front Portch (Exempt)30.25 Existing Basement Level Wall Calculations Basement Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XB1 153.75 0.00 XB2 100.50 0.00 XB3 80.00 0.00 XB4 8.25 0.00 XB5 66.00 0.00 XB6 389.25 0.00 XB7 144.50 0.00 XB8 9.50 0.00 XB9 249.50 0.00 XB10 418.00 85.25 XB11 80.00 63.00 XB12 39.50 31.25 Overall Total Wall Areas (Sq Ft)1,738.75 Exposed Wall Area (Sq Ft)179.50 % of Exposed Wall (Exposed / Total)10.32% Existing Basement Level Floor Area Calculations Basement Level Gross Floor Area (Sq Ft)2,064.75 Basement Level Countable Floor Area (Sq Ft)213.15 Basement Level Area x Percent Exposed @ 10.32% Existing Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XL1 84.25 0.00 XL2 103.00 57.00 XL3 80.75 54.50 XL4 8.00 5.25 XL5 82.25 18.75 XL6 8.00 1.00 XL7 86.75 6.00 XL8 224.75 0.00 XL9 101.00 0.00 XL10 150.50 0.00 XL11 148.75 0.00 XL12 12.75 0.00 XL13 253.75 89.50 XL14 177.25 177.25 XL15 201.25 201.25 XL16 200.25 200.25 XL17 201.25 201.25 XL18 43.25 43.25 XL19 82.75 82.75 XL20 19.25 19.25 Overall Total Wall Areas (Sq Ft)2,269.75 Exposed Wall Area (Sq Ft)1,157.25 % of Exposed Wall (Exposed / Total)50.99% Existing Lower Level Floor Area Calculations Lower Level Gross Floor Area (Sq Ft)2,347.00 Lower Level Exempt (Open to Below / T.O. Circulation)0.00 Garage Gross Floor Area (Sq Ft)483.00 Garage after Exemption (0-250 @ 0% 250-500 @ 50%)116.50 (500-250)/2 Lower Level & Garage Floor Area After Exemptions 2,463.50 Lower Level Countable Floor Area (Sq Ft)1,256.03 Lower Level Area x Percent Exposed @ 50.99% Existing Main Level Wall Calculations Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XM1 368.00 368.00 XM2 124.25 124.25 XM3 73.25 73.25 XM4 8.50 8.50 XM5 73.50 73.50 XM6 73.50 73.50 XM7 8.75 8.75 XM8 36.00 36.00 XM9 98.00 98.00 XM10 181.75 181.75 XM11 167.50 165.75 XM12 14.50 12.50 XM13 66.25 51.75 XM14 118.50 82.00 XM15 14.50 9.75 XM16 51.75 35.50 XM17 14.50 9.75 XM18 211.25 156.75 XM19 243.00 184.50 XM20 40.50 39.00 XM21 100.00 99.00 XM22 151.00 151.00 XM23 151.50 151.50 XM24 76.75 76.75 XM25 175.50 175.50 XM26 125.50 125.50 XM27 29.00 29.00 XM28 14.00 14.00 XM29 140.50 140.50 XM30 194.25 194.25 XM31 175.50 175.50 XM32 171.25 171.25 Overall Total Wall Areas (Sq Ft)3,492.50 Exposed Wall Area (Sq Ft)3,296.50 % of Exposed Wall (Exposed / Total)94.39% Existing Main Level Floor Area Calculations Main Level Gross Floor Area (Sq Ft)2,756.50 Main Level Exempt (Open to Below / T.O. Circulation)110.25 Main Level After Exemptions (Sq Ft)2,646.25 2756.50-110.25 Main Level Countable Floor Area (Sq Ft)2,497.74 Main Level Area x Percent Exposed @ 94.39% Front Porch Gross Floor Area (Sq Ft)66.00 Exempt Front Porch Main Deck Gross Floor Area ( Sq Ft)780.50 Existing ADU Wall Calculations ADU Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XA1 81.25 81.25 XA2 66.50 66.50 XA3 106.50 106.50 XA4 190.00 179.00 XA5 106.50 74.75 XA6 9.75 8.00 XA7 81.25 64.00 XA8 105.50 100.25 Overall Total Wall Areas (Sq Ft)747.25 Exposed Wall Area (Sq Ft)680.25 % of Exposed Wall (Exposed / Total)91.03% Existing ADU Floor Area Calculations ADU Gross Floor Area (Sq Ft)405.50 ADU Countable Floor Area (Sq Ft)369.14 ADU Area x Percent Exposed @ 91.03% Front Porch Gross Floor Area (Sq Ft)30.25 Exempt Front Porch Total Exsiting Floor Area Calculations Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% of Allowable FAR 0.00 3,965.97 x 0.15 Countable Deck Floor Area (Sq Ft)780.50 Total Existing Floor Area 5,116.57 Existing Floor Area Calculations Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Existing Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% Allowable FAR (NA)0.00 3,966.92 x 0.15 Countable Deck Floor Area (Sq Ft)0.00 Total Existing Countable Floor Area 4,336.07 Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Proposed Interior Floor Area (Sq Ft)4,302.08 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.08 Total Proposed Floor Area Calculations NOTE: The structure exists as a legally permitted nonconformity. Proposed house to retain current measured floor area per the plans. Total Existing Floor Area Calculations W/ ADU (TOTAL ALLOWABLE FLOOR AREA) 0 4'8'16'SCALE: 1/8" = 1'-0"2 EXISTING BASEMENT LEVEL EXPOSURE 0 4'8'16'SCALE: 1/8" = 1'-0"1 EXISTING BASEMENT LEVEL FLOOR AREA COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-011X FLOOR AREA CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 COUNTABLE FAR PLAN LEGEND DECK GARAGE EXEMPT - T.O. CIRCULATION OR OPEN TO BELOW EXEMPT - FRONT PORCH EXEMPT - ON-GRADE PATIO40.00 sq ft 6.50 sq ft19.00 sq ft 1.25 sq ft 2.50 sq ft 64.25 sq ft 89.50 sq ft 84.25 sq ft 103.00 sq ft 80.75 sq ft 8.00 sq ft 82.25 sq ft 8.00 sq ft 86.75 sq ft 224.75 sq ft 101.00 sq ft 150.50 sq ft 148.75 sq ft 12.75 sq ft 253.75 sq ft 177.25 sq ft 204.25 sq ft 200.25 sq ft 204.25 sq ft 43.25 sq ft 82.75 sq ft 19.25 sq ft XL1 XL2 XL3 XL4 XL5 XL6 XL7 XL8 XL9 XL10 XL11 XL12 XL13 XL14 XL15 XL16 XL17 XL18 XL19 XL20 190.00 sq ft 106.50 sq ft 9.75 sq ft 81.25 sq ft 109.75 sq ft 81.25 sq ft 62.00 sq ft 106.50 sq ft 179.00 sq ft 74.75 sq ft 8.00 sq ft 64.00 sq ft 104.75 sq ft XA1 XA2 XA3 XA4 XA5 XA6 XA7 XA8 110 Neale Avenue Existing Basement Level Floor Area Basement Level Floor Area without Exemptions (Sq Ft)2,064.75 Existing Lower Level Floor Area Lower Level Floor Area without Exemptions (Sq Ft)2,347.00 Lower Level Exempt (OTB / T.O. Circ)0.00 Garage Floor Area without Exemptions (Sq Ft)483.00 Existing Main Level Floor Area Main Level Floor Area without Exemptions (Sq Ft)2,756.50 Main Level Exempt (T.O. Circ)110.25 Front Portch (Exempt)66.00 Main Level Deck Floor Area without Exemptions (Sq Ft)780.50 Existing "ADU" Floor Area ADU Gross Floor Area (Sq Ft)405.50 Front Portch (Exempt)30.25 Existing Basement Level Wall Calculations Basement Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XB1 153.75 0.00 XB2 100.50 0.00 XB3 80.00 0.00 XB4 8.25 0.00 XB5 66.00 0.00 XB6 389.25 0.00 XB7 144.50 0.00 XB8 9.50 0.00 XB9 249.50 0.00 XB10 418.00 85.25 XB11 80.00 63.00 XB12 39.50 31.25 Overall Total Wall Areas (Sq Ft)1,738.75 Exposed Wall Area (Sq Ft)179.50 % of Exposed Wall (Exposed / Total)10.32% Existing Basement Level Floor Area Calculations Basement Level Gross Floor Area (Sq Ft)2,064.75 Basement Level Countable Floor Area (Sq Ft)213.15 Basement Level Area x Percent Exposed @ 10.32% Existing Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XL1 84.25 0.00 XL2 103.00 57.00 XL3 80.75 54.50 XL4 8.00 5.25 XL5 82.25 18.75 XL6 8.00 1.00 XL7 86.75 6.00 XL8 224.75 0.00 XL9 101.00 0.00 XL10 150.50 0.00 XL11 148.75 0.00 XL12 12.75 0.00 XL13 253.75 89.50 XL14 177.25 177.25 XL15 201.25 201.25 XL16 200.25 200.25 XL17 201.25 201.25 XL18 43.25 43.25 XL19 82.75 82.75 XL20 19.25 19.25 Overall Total Wall Areas (Sq Ft)2,269.75 Exposed Wall Area (Sq Ft)1,157.25 % of Exposed Wall (Exposed / Total)50.99% Existing Lower Level Floor Area Calculations Lower Level Gross Floor Area (Sq Ft)2,347.00 Lower Level Exempt (Open to Below / T.O. Circulation)0.00 Garage Gross Floor Area (Sq Ft)483.00 Garage after Exemption (0-250 @ 0% 250-500 @ 50%)116.50 (500-250)/2 Lower Level & Garage Floor Area After Exemptions 2,463.50 Lower Level Countable Floor Area (Sq Ft)1,256.03 Lower Level Area x Percent Exposed @ 50.99% Existing Main Level Wall Calculations Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XM1 368.00 368.00 XM2 124.25 124.25 XM3 73.25 73.25 XM4 8.50 8.50 XM5 73.50 73.50 XM6 73.50 73.50 XM7 8.75 8.75 XM8 36.00 36.00 XM9 98.00 98.00 XM10 181.75 181.75 XM11 167.50 165.75 XM12 14.50 12.50 XM13 66.25 51.75 XM14 118.50 82.00 XM15 14.50 9.75 XM16 51.75 35.50 XM17 14.50 9.75 XM18 211.25 156.75 XM19 243.00 184.50 XM20 40.50 39.00 XM21 100.00 99.00 XM22 151.00 151.00 XM23 151.50 151.50 XM24 76.75 76.75 XM25 175.50 175.50 XM26 125.50 125.50 XM27 29.00 29.00 XM28 14.00 14.00 XM29 140.50 140.50 XM30 194.25 194.25 XM31 175.50 175.50 XM32 171.25 171.25 Overall Total Wall Areas (Sq Ft)3,492.50 Exposed Wall Area (Sq Ft)3,296.50 % of Exposed Wall (Exposed / Total)94.39% Existing Main Level Floor Area Calculations Main Level Gross Floor Area (Sq Ft)2,756.50 Main Level Exempt (Open to Below / T.O. Circulation)110.25 Main Level After Exemptions (Sq Ft)2,646.25 2756.50-110.25 Main Level Countable Floor Area (Sq Ft)2,497.74 Main Level Area x Percent Exposed @ 94.39% Front Porch Gross Floor Area (Sq Ft)66.00 Exempt Front Porch Main Deck Gross Floor Area ( Sq Ft)780.50 Existing ADU Wall Calculations ADU Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XA1 81.25 81.25 XA2 66.50 66.50 XA3 106.50 106.50 XA4 190.00 179.00 XA5 106.50 74.75 XA6 9.75 8.00 XA7 81.25 64.00 XA8 105.50 100.25 Overall Total Wall Areas (Sq Ft)747.25 Exposed Wall Area (Sq Ft)680.25 % of Exposed Wall (Exposed / Total)91.03% Existing ADU Floor Area Calculations ADU Gross Floor Area (Sq Ft)405.50 ADU Countable Floor Area (Sq Ft)369.14 ADU Area x Percent Exposed @ 91.03% Front Porch Gross Floor Area (Sq Ft)30.25 Exempt Front Porch Total Exsiting Floor Area Calculations Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% of Allowable FAR 0.00 3,965.97 x 0.15 Countable Deck Floor Area (Sq Ft)780.50 Total Existing Floor Area 5,116.57 Existing Floor Area Calculations 483.00 sq ft 405.50 sq ft XL1 XL2 XL3XL4 XL5 XL6 XL7 XL8 XL9 XL10 XL11 XL12 XL13 XL14 XL15 XL16 XL17 XL18 XL19 XL20 XA1 XA2 XA3 XA4 XA5 XA6 XA7 XA8 CRAWL SPACE 9 9 2,347.75 sq ft 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Existing Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% Allowable FAR (NA)0.00 3,966.92 x 0.15 Countable Deck Floor Area (Sq Ft)0.00 Total Existing Countable Floor Area 4,336.07 Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Proposed Interior Floor Area (Sq Ft)4,302.08 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.08 Total Proposed Floor Area Calculations NOTE: The structure exists as a legally permitted nonconformity. Proposed house to retain current measured floor area per the plans. Total Existing Floor Area Calculations W/ ADU (TOTAL ALLOWABLE FLOOR AREA) 0 4'8'16'SCALE: 1/8" = 1'-0"2 EXISTING GARAGE (MIDDLE) LEVEL EXPOSURE 0 4'8'16'SCALE: 1/8" = 1'-0"3 EXISTING ADU EXPOSURE 0 4'8'16'SCALE: 1/8" = 1'-0"1 EXISTING GARAGE (MIDDLE) LEVEL FLOOR AREA COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-012X FLOOR AREA CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 COUNTABLE FAR PLAN LEGEND DECK GARAGE EXEMPT - T.O. CIRCULATION OR OPEN TO BELOW EXEMPT - FRONT PORCH EXEMPT - ON-GRADE PATIO 14.50 sq ft 51.75 sq ft14.50 sq ft 118.50 sq ft66.25 sq ft 14.50 sq ft 164.50 sq ft 238.50 sq ft203.00 sq ft 149.50 sq ft 217.00 sq ft 178.50 sq ft 363.75 sq ft 181.25 sq ft 80.00 sq ft 162.50 sq ft 12.75 sq ft 53.25 sq ft 83.00 sq ft 10.00 sq ft 35.50 sq ft 9.75 sq ft 38.00 sq ft 103.50 sq ft 151.00 sq ft 151.50 sq ft 75.75 sq ft 188.50 sq ft 134.75 sq ft 31.25 sq ft 15.00 sq ft 151.00 sq ft 188.50 sq ft 181.25 sq ft 9.75 sq ft 85.50 sq ft 85.50 sq ft 9.75 sq ft 35.25 sq ft 103.50 sq ft 181.75 sq ft XM1 XM2 XM3 XM11 XM12 XM13 XM14 XM15 XM16 XM17 XM18 XM19 XM20 XM21 XM22 XM23 XM24 XM25 XM26 XM27 XM28 XM29 XM30 XM31 XM32 XM4 XM5 XM6 XM7 XM8 XM9 XM10 65.00 sq ft 189.00 sq ft 288.25 sq ft 134.25 sq ft FF 129.25 sq ft XM1 XM2 XM3XM4 XM5 XM6 XM7 XM8 XM9 XM10 XM11 XM12 XM13 XM14 XM15XM16 XM17 XM18 XM19 XM20 XM21 XM22 XM23 XM24 XM25 XM26 XM27 XM28 XM29 XM30 XM31 XM32 60.50 sq ft 9 9 RG 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 2,756.50 sq ft 42.25 sq ft 110 Neale Avenue Existing Basement Level Floor Area Basement Level Floor Area without Exemptions (Sq Ft)2,064.75 Existing Lower Level Floor Area Lower Level Floor Area without Exemptions (Sq Ft)2,347.00 Lower Level Exempt (OTB / T.O. Circ)0.00 Garage Floor Area without Exemptions (Sq Ft)483.00 Existing Main Level Floor Area Main Level Floor Area without Exemptions (Sq Ft)2,756.50 Main Level Exempt (T.O. Circ)110.25 Front Portch (Exempt)66.00 Main Level Deck Floor Area without Exemptions (Sq Ft)780.50 Existing "ADU" Floor Area ADU Gross Floor Area (Sq Ft)405.50 Front Portch (Exempt)30.25 Existing Basement Level Wall Calculations Basement Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XB1 153.75 0.00 XB2 100.50 0.00 XB3 80.00 0.00 XB4 8.25 0.00 XB5 66.00 0.00 XB6 389.25 0.00 XB7 144.50 0.00 XB8 9.50 0.00 XB9 249.50 0.00 XB10 418.00 85.25 XB11 80.00 63.00 XB12 39.50 31.25 Overall Total Wall Areas (Sq Ft)1,738.75 Exposed Wall Area (Sq Ft)179.50 % of Exposed Wall (Exposed / Total)10.32% Existing Basement Level Floor Area Calculations Basement Level Gross Floor Area (Sq Ft)2,064.75 Basement Level Countable Floor Area (Sq Ft)213.15 Basement Level Area x Percent Exposed @ 10.32% Existing Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XL1 84.25 0.00 XL2 103.00 57.00 XL3 80.75 54.50 XL4 8.00 5.25 XL5 82.25 18.75 XL6 8.00 1.00 XL7 86.75 6.00 XL8 224.75 0.00 XL9 101.00 0.00 XL10 150.50 0.00 XL11 148.75 0.00 XL12 12.75 0.00 XL13 253.75 89.50 XL14 177.25 177.25 XL15 201.25 201.25 XL16 200.25 200.25 XL17 201.25 201.25 XL18 43.25 43.25 XL19 82.75 82.75 XL20 19.25 19.25 Overall Total Wall Areas (Sq Ft)2,269.75 Exposed Wall Area (Sq Ft)1,157.25 % of Exposed Wall (Exposed / Total)50.99% Existing Lower Level Floor Area Calculations Lower Level Gross Floor Area (Sq Ft)2,347.00 Lower Level Exempt (Open to Below / T.O. Circulation)0.00 Garage Gross Floor Area (Sq Ft)483.00 Garage after Exemption (0-250 @ 0% 250-500 @ 50%)116.50 (500-250)/2 Lower Level & Garage Floor Area After Exemptions 2,463.50 Lower Level Countable Floor Area (Sq Ft)1,256.03 Lower Level Area x Percent Exposed @ 50.99% Existing Main Level Wall Calculations Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XM1 368.00 368.00 XM2 124.25 124.25 XM3 73.25 73.25 XM4 8.50 8.50 XM5 73.50 73.50 XM6 73.50 73.50 XM7 8.75 8.75 XM8 36.00 36.00 XM9 98.00 98.00 XM10 181.75 181.75 XM11 167.50 165.75 XM12 14.50 12.50 XM13 66.25 51.75 XM14 118.50 82.00 XM15 14.50 9.75 XM16 51.75 35.50 XM17 14.50 9.75 XM18 211.25 156.75 XM19 243.00 184.50 XM20 40.50 39.00 XM21 100.00 99.00 XM22 151.00 151.00 XM23 151.50 151.50 XM24 76.75 76.75 XM25 175.50 175.50 XM26 125.50 125.50 XM27 29.00 29.00 XM28 14.00 14.00 XM29 140.50 140.50 XM30 194.25 194.25 XM31 175.50 175.50 XM32 171.25 171.25 Overall Total Wall Areas (Sq Ft)3,492.50 Exposed Wall Area (Sq Ft)3,296.50 % of Exposed Wall (Exposed / Total)94.39% Existing Main Level Floor Area Calculations Main Level Gross Floor Area (Sq Ft)2,756.50 Main Level Exempt (Open to Below / T.O. Circulation)110.25 Main Level After Exemptions (Sq Ft)2,646.25 2756.50-110.25 Main Level Countable Floor Area (Sq Ft)2,497.74 Main Level Area x Percent Exposed @ 94.39% Front Porch Gross Floor Area (Sq Ft)66.00 Exempt Front Porch Main Deck Gross Floor Area ( Sq Ft)780.50 Existing ADU Wall Calculations ADU Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) XA1 81.25 81.25 XA2 66.50 66.50 XA3 106.50 106.50 XA4 190.00 179.00 XA5 106.50 74.75 XA6 9.75 8.00 XA7 81.25 64.00 XA8 105.50 100.25 Overall Total Wall Areas (Sq Ft)747.25 Exposed Wall Area (Sq Ft)680.25 % of Exposed Wall (Exposed / Total)91.03% Existing ADU Floor Area Calculations ADU Gross Floor Area (Sq Ft)405.50 ADU Countable Floor Area (Sq Ft)369.14 ADU Area x Percent Exposed @ 91.03% Front Porch Gross Floor Area (Sq Ft)30.25 Exempt Front Porch Total Exsiting Floor Area Calculations Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% of Allowable FAR 0.00 3,965.97 x 0.15 Countable Deck Floor Area (Sq Ft)780.50 Total Existing Floor Area 5,116.57 Existing Floor Area Calculations Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Existing Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% Allowable FAR (NA)0.00 3,966.92 x 0.15 Countable Deck Floor Area (Sq Ft)0.00 Total Existing Countable Floor Area 4,336.07 Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Proposed Interior Floor Area (Sq Ft)4,302.08 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.08 Total Proposed Floor Area Calculations NOTE: The structure exists as a legally permitted nonconformity. Proposed house to retain current measured floor area per the plans. Total Existing Floor Area Calculations W/ ADU (TOTAL ALLOWABLE FLOOR AREA) 0 4'8'16'SCALE: 1/8" = 1'-0"2 EXISTING MAIN LEVEL EXPOSURE 0 4'8'16'SCALE: 1/8" = 1'-0"1 EXISTING MAIN LEVEL FLOOR AREA COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-010 FLOOR AREA CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 COUNTABLE FAR PLAN LEGEND DECK GARAGE EXEMPT - T.O. CIRCULATION OR OPEN TO BELOW EXEMPT - FRONT PORCH EXEMPT - ON-GRADE PATIO 248.00 sq ft 47.50 sq ft 146.50 sq ft 77.25 sq ft 176.50 sq ft 114.75 sq ft 153.75 sq ft 378.25 sq ft 147.50 sq ft 12.50 sq ft 198.25 sq ft 564.25 sq ft 421.00 sq ft 40.50 sq ft 17.25 sq ft 17.25 sq ft 17.25 sq ft 17.25 sq ft 17.25 sq ft 17.25 sq ft B1 B2 B3 B4 B5 B6 B7 B11 B12 B13 B14 B8 B9 B10 Proposed Floor Area Calculations 110 Neale Proposed Basement Level Floor Area Basement Level Floor Area without Exemptions (Sq Ft)4,149.50 Prposed Garage Level Floor Area Lower Level Floor Area without Exemptions (Sq Ft)2,801.75 Lower Level Exempt (OTB / T.O. Circ)0.00 Garage Level Patio (Exempt)257,25 Garage Floor Area without Exemptions (Sq Ft)491.75 Proposed Main Level Floor Area Calculations Main Level Floor Area without Exemptions (Sq Ft)2,890.75 Main Level Exempt (T.O. Circ)210.50 Main Level Patio (Exempt)463.25 Front Portch (Exempt)228.75 Main Level Deck Floor Area without Exemptions (Sq Ft)778.50 Proposed "ADU" Floor Area Calculations ADU Gross Floor Area (Sq Ft)0.00 Front Portch (Exempt)0.00 FAR Proposed Basement Level Wall Calculations Basement Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PB1 176.50 0.00 PB2 114.75 0.00 PB3 153.75 17.25 PB4 378.25 0.00 PB5 147.50 0.00 PB6 12.50 0.00 PB7 248.00 17.25 PB8 47.50 17.25 PB9 146.50 0.00 PB10 77.25 0.00 PB11 198.25 17.25 PB12 564.25 0.00 PB13 421.00 34.50 PB14 40.50 0.00 Overall Total Wall Areas (Sq Ft)2,726.50 Exposed Wall Area (Sq Ft)103.50 % of Exposed Wall (Exposed / Total)3.80% Proposed Basement Level Floor Area Calculations Basement Level Gross Floor Area (Sq Ft)4,149.50 Basement Level Countable Floor Area (Sq Ft)157.52 Basement Level Area x Percent Exposed @ 3.8% Proposed Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PL1 85.50 0.00 PL2 54.25 0.00 PL3 262.25 75.25 PL4 221.75 0.00 PL5 103.00 17.00 PL6 148.25 17.00 PL7 146.75 0.00 PL8 12.50 0.00 PL9 391.50 199.50 PL10 136.50 109.00 PL11 190.25 136.25 PL12 188.00 174.75 PL13 190.25 190.25 PL14 17.25 17.25 PL15 44.50 44.50 PL16 367.00 367.00 PL17 108.00 105.00 PL18 43.25 38.75 PL19 60.50 48.25 Overall Total Wall Areas (Sq Ft)2,771.25 Exposed Wall Area (Sq Ft)1,539.75 % of Exposed Wall (Exposed / Total)55.56% Proposed Lower Level Floor Area Calculations Lower Level Gross Floor Area (Sq Ft)2,801.75 Lower Level Exempt (Open to Below / T.O. Circulation)0.00 Garage Gross Floor Area (Sq Ft)491.75 Garage after Exemption (0-250 @ 0% 250-500 @ 50%)120.88 (500-250)/2 Lower Level & Garage Floor Area After Exemptions 2,922.63 Lower Level Countable Floor Area (Sq Ft)1,623.86 Lower Level Area x Percent Exposed @ 55.56% Proposed Main Level Wall Calculations Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PM1 297.75 297.75 PM2 177.25 177.25 PM3 244.25 244.25 PM4 53.50 53.50 PM5 47.75 47.75 PM6 15.50 15.50 PM7 167.50 165.75 PM8 15.50 13.75 PM9 65.00 51.75 PM10 116.00 80.50 PM11 14.25 9.75 PM12 50.25 34.00 PM13 14.25 9.75 PM14 211.25 157.25 PM15 236.25 176.50 PM16 36.50 36.50 PM17 99.00 99.00 PM18 151.00 151.00 PM19 149.00 149.00 PM20 85.00 85.00 PM21 185.25 185.25 PM22 132.50 132.50 PM23 30.50 30.50 PM24 14.75 14.75 PM25 149.00 149.00 PM26 201.50 201.50 PM27 170.00 170.00 PM28 82.50 82.50 Overall Total Wall Areas (Sq Ft)3,212.75 Exposed Wall Area (Sq Ft)3,021.50 % of Exposed Wall (Exposed / Total)94.05% Proposed Main Level Floor Area Calculations Main Level Gross Floor Area (Sq Ft)2,890.75 Main Level Exempt (Open to Below / T.O. Circulation)210.50 Main Level After Exemptions (Sq Ft)2,680.25 2720.50-119.25 Main Level Countable Interior Floor Area (Sq Ft)2,520.70 Main Level Area x Percent Exposed @ 94.05% Front Porch Gross Floor Area (Sq Ft)228.75 Exempt Front Porch Main Deck Gross Floor Area ( Sq Ft)778.50 Main Level Patio Floor Area (Sq Ft)461.00 Total Proposed Floor Area Calculations Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Interior Floor Area (Sq Ft)4,302.07 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.07 Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Existing Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% Allowable FAR (NA)0.00 3,966.92 x 0.15 Countable Deck Floor Area (Sq Ft)0.00 Total Existing Countable Floor Area 4,336.07 Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Proposed Interior Floor Area (Sq Ft)4,302.08 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.08 Total Proposed Floor Area Calculations NOTE: The structure exists as a legally permitted nonconformity. Proposed house to retain current measured floor area per the plans. Total Existing Floor Area Calculations W/ ADU (TOTAL ALLOWABLE FLOOR AREA) B1 B2 B3 B4 B5 B6 B12 B11 B10 B9 B8 B7 B13B14 CRAWL SPACE 9 9 4,149.50 sq ft 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L 0 4'8'16'SCALE: 1/8" = 1'-0"2 PROPOSED BASEMENT LEVEL EXPOSURE 0 4'8'16'SCALE: 1/8" = 1'-0"1 PROPOSED BASEMENT LEVEL FLOOR AREA COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-011 FLOOR AREA CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 COUNTABLE FAR PLAN LEGEND DECK GARAGE EXEMPT - T.O. CIRCULATION OR OPEN TO BELOW EXEMPT - FRONT PORCH EXEMPT - ON-GRADE PATIO 199.50 sq ft 127.50 sq ft 190.25 sq ft 84.50 sq ft 54.25 sq ft 262.25 sq ft 72.25 sq ft 221.75 sq ft 103.00 sq ft 148.25 sq ft 146.75 sq ft 12.50 sq ft 109.00 sq ft 188.00 sq ft 190.25 sq ft 367.00 sq ft 17.00 sq ft 17.00 sq ft 108.00 sq ft 43.25 sq ft 60.50 sq ft44.50 sq ft 48.25 sq ft L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L16 L17 L18 L19L14L15 257.25 sq ft L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17L18 L19 CRAWL SPACE 491.75 sq ft 2,801.75 sq ft 9 9 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L Proposed Floor Area Calculations 110 Neale Proposed Basement Level Floor Area Basement Level Floor Area without Exemptions (Sq Ft)4,149.50 Prposed Garage Level Floor Area Lower Level Floor Area without Exemptions (Sq Ft)2,801.75 Lower Level Exempt (OTB / T.O. Circ)0.00 Garage Level Patio (Exempt)257,25 Garage Floor Area without Exemptions (Sq Ft)491.75 Proposed Main Level Floor Area Calculations Main Level Floor Area without Exemptions (Sq Ft)2,890.75 Main Level Exempt (T.O. Circ)210.50 Main Level Patio (Exempt)463.25 Front Portch (Exempt)228.75 Main Level Deck Floor Area without Exemptions (Sq Ft)778.50 Proposed "ADU" Floor Area Calculations ADU Gross Floor Area (Sq Ft)0.00 Front Portch (Exempt)0.00 FAR Proposed Basement Level Wall Calculations Basement Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PB1 176.50 0.00 PB2 114.75 0.00 PB3 153.75 17.25 PB4 378.25 0.00 PB5 147.50 0.00 PB6 12.50 0.00 PB7 248.00 17.25 PB8 47.50 17.25 PB9 146.50 0.00 PB10 77.25 0.00 PB11 198.25 17.25 PB12 564.25 0.00 PB13 421.00 34.50 PB14 40.50 0.00 Overall Total Wall Areas (Sq Ft)2,726.50 Exposed Wall Area (Sq Ft)103.50 % of Exposed Wall (Exposed / Total)3.80% Proposed Basement Level Floor Area Calculations Basement Level Gross Floor Area (Sq Ft)4,149.50 Basement Level Countable Floor Area (Sq Ft)157.52 Basement Level Area x Percent Exposed @ 3.8% Proposed Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PL1 85.50 0.00 PL2 54.25 0.00 PL3 262.25 75.25 PL4 221.75 0.00 PL5 103.00 17.00 PL6 148.25 17.00 PL7 146.75 0.00 PL8 12.50 0.00 PL9 391.50 199.50 PL10 136.50 109.00 PL11 190.25 136.25 PL12 188.00 174.75 PL13 190.25 190.25 PL14 17.25 17.25 PL15 44.50 44.50 PL16 367.00 367.00 PL17 108.00 105.00 PL18 43.25 38.75 PL19 60.50 48.25 Overall Total Wall Areas (Sq Ft)2,771.25 Exposed Wall Area (Sq Ft)1,539.75 % of Exposed Wall (Exposed / Total)55.56% Proposed Lower Level Floor Area Calculations Lower Level Gross Floor Area (Sq Ft)2,801.75 Lower Level Exempt (Open to Below / T.O. Circulation)0.00 Garage Gross Floor Area (Sq Ft)491.75 Garage after Exemption (0-250 @ 0% 250-500 @ 50%)120.88 (500-250)/2 Lower Level & Garage Floor Area After Exemptions 2,922.63 Lower Level Countable Floor Area (Sq Ft)1,623.86 Lower Level Area x Percent Exposed @ 55.56% Proposed Main Level Wall Calculations Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PM1 297.75 297.75 PM2 177.25 177.25 PM3 244.25 244.25 PM4 53.50 53.50 PM5 47.75 47.75 PM6 15.50 15.50 PM7 167.50 165.75 PM8 15.50 13.75 PM9 65.00 51.75 PM10 116.00 80.50 PM11 14.25 9.75 PM12 50.25 34.00 PM13 14.25 9.75 PM14 211.25 157.25 PM15 236.25 176.50 PM16 36.50 36.50 PM17 99.00 99.00 PM18 151.00 151.00 PM19 149.00 149.00 PM20 85.00 85.00 PM21 185.25 185.25 PM22 132.50 132.50 PM23 30.50 30.50 PM24 14.75 14.75 PM25 149.00 149.00 PM26 201.50 201.50 PM27 170.00 170.00 PM28 82.50 82.50 Overall Total Wall Areas (Sq Ft)3,212.75 Exposed Wall Area (Sq Ft)3,021.50 % of Exposed Wall (Exposed / Total)94.05% Proposed Main Level Floor Area Calculations Main Level Gross Floor Area (Sq Ft)2,890.75 Main Level Exempt (Open to Below / T.O. Circulation)210.50 Main Level After Exemptions (Sq Ft)2,680.25 2720.50-119.25 Main Level Countable Interior Floor Area (Sq Ft)2,520.70 Main Level Area x Percent Exposed @ 94.05% Front Porch Gross Floor Area (Sq Ft)228.75 Exempt Front Porch Main Deck Gross Floor Area ( Sq Ft)778.50 Main Level Patio Floor Area (Sq Ft)461.00 Total Proposed Floor Area Calculations Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Interior Floor Area (Sq Ft)4,302.07 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.07 Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Existing Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% Allowable FAR (NA)0.00 3,966.92 x 0.15 Countable Deck Floor Area (Sq Ft)0.00 Total Existing Countable Floor Area 4,336.07 Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Proposed Interior Floor Area (Sq Ft)4,302.08 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.08 Total Proposed Floor Area Calculations NOTE: The structure exists as a legally permitted nonconformity. Proposed house to retain current measured floor area per the plans. Total Existing Floor Area Calculations W/ ADU (TOTAL ALLOWABLE FLOOR AREA) 0 4'8'16'SCALE: 1/8" = 1'-0"2 PROPOSED GARAGE (MIDDLE) LEVEL EXPOSURE 0 4'8'16'SCALE: 1/8" = 1'-0"1 PROPOSED GARAGE LEVEL FLOOR AREA COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION Z-012 FLOOR AREA CALCULATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 COUNTABLE FAR PLAN LEGEND DECK GARAGE EXEMPT - T.O. CIRCULATION OR OPEN TO BELOW EXEMPT - FRONT PORCH EXEMPT - ON-GRADE PATIO 15.50 sq ft 13.00 sq ft297.75 sq ft 170.00 sq ft 177.25 sq ft 244.25 sq ft 49.50 sq ft 44.25 sq ft 15.50 sq ft 167.50 sq ft 163.00 sq ft 65.00 sq ft 116.00 sq ft 14.25 sq ft 50.25 sq ft 14.00 sq ft 211.25 sq ft 236.25 sq ft 36.50 sq ft 99.00 sq ft 151.00 sq ft 149.00 sq ft 85.00 sq ft 185.25 sq ft 132.50 sq ft 30.50 sq ft 14.75 sq ft 149.00 sq ft 201.50 sq ft 82.50 sq ft 176.50 sq ft PM1 PM2 PM3 PM4 PM5 PM6 PM7 PM8 PM9 PM10 PM11 PM12 PM13 PM14 PM15 PM16 PM17 PM18 PM19 PM20 PM21 PM22 PM23 PM24 PM25 PM26 PM27 PM28 48.00 sq ft 74.00 sq ft 9.00 sq ft 31.25 sq ft 8.50 sq ft 149.75 sq ft FF 2,890.75 sq ft M1 M2 M3 M4 M5M6 M7 M8 M9 M10 M11M12 M13 M14 M15 M16 M17 M18 M19 M20 M21 M22 M23 M24 M25 M26 M27 M28 778.50 sq ft 416.50 sq ft 46.75 sq ft 210.50 sq ft 228.75 sq ft 9 9 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L RG Proposed Floor Area Calculations 110 Neale Proposed Basement Level Floor Area Basement Level Floor Area without Exemptions (Sq Ft)4,149.50 Prposed Garage Level Floor Area Lower Level Floor Area without Exemptions (Sq Ft)2,801.75 Lower Level Exempt (OTB / T.O. Circ)0.00 Garage Level Patio (Exempt)257,25 Garage Floor Area without Exemptions (Sq Ft)491.75 Proposed Main Level Floor Area Calculations Main Level Floor Area without Exemptions (Sq Ft)2,890.75 Main Level Exempt (T.O. Circ)210.50 Main Level Patio (Exempt)463.25 Front Portch (Exempt)228.75 Main Level Deck Floor Area without Exemptions (Sq Ft)778.50 Proposed "ADU" Floor Area Calculations ADU Gross Floor Area (Sq Ft)0.00 Front Portch (Exempt)0.00 FAR Proposed Basement Level Wall Calculations Basement Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PB1 176.50 0.00 PB2 114.75 0.00 PB3 153.75 17.25 PB4 378.25 0.00 PB5 147.50 0.00 PB6 12.50 0.00 PB7 248.00 17.25 PB8 47.50 17.25 PB9 146.50 0.00 PB10 77.25 0.00 PB11 198.25 17.25 PB12 564.25 0.00 PB13 421.00 34.50 PB14 40.50 0.00 Overall Total Wall Areas (Sq Ft)2,726.50 Exposed Wall Area (Sq Ft)103.50 % of Exposed Wall (Exposed / Total)3.80% Proposed Basement Level Floor Area Calculations Basement Level Gross Floor Area (Sq Ft)4,149.50 Basement Level Countable Floor Area (Sq Ft)157.52 Basement Level Area x Percent Exposed @ 3.8% Proposed Lower Level Wall Calculations Lower Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PL1 85.50 0.00 PL2 54.25 0.00 PL3 262.25 75.25 PL4 221.75 0.00 PL5 103.00 17.00 PL6 148.25 17.00 PL7 146.75 0.00 PL8 12.50 0.00 PL9 391.50 199.50 PL10 136.50 109.00 PL11 190.25 136.25 PL12 188.00 174.75 PL13 190.25 190.25 PL14 17.25 17.25 PL15 44.50 44.50 PL16 367.00 367.00 PL17 108.00 105.00 PL18 43.25 38.75 PL19 60.50 48.25 Overall Total Wall Areas (Sq Ft)2,771.25 Exposed Wall Area (Sq Ft)1,539.75 % of Exposed Wall (Exposed / Total)55.56% Proposed Lower Level Floor Area Calculations Lower Level Gross Floor Area (Sq Ft)2,801.75 Lower Level Exempt (Open to Below / T.O. Circulation)0.00 Garage Gross Floor Area (Sq Ft)491.75 Garage after Exemption (0-250 @ 0% 250-500 @ 50%)120.88 (500-250)/2 Lower Level & Garage Floor Area After Exemptions 2,922.63 Lower Level Countable Floor Area (Sq Ft)1,623.86 Lower Level Area x Percent Exposed @ 55.56% Proposed Main Level Wall Calculations Main Level Wall Label Total Wall Area (Sq Ft)Exposed Wall Area (Sq Ft) PM1 297.75 297.75 PM2 177.25 177.25 PM3 244.25 244.25 PM4 53.50 53.50 PM5 47.75 47.75 PM6 15.50 15.50 PM7 167.50 165.75 PM8 15.50 13.75 PM9 65.00 51.75 PM10 116.00 80.50 PM11 14.25 9.75 PM12 50.25 34.00 PM13 14.25 9.75 PM14 211.25 157.25 PM15 236.25 176.50 PM16 36.50 36.50 PM17 99.00 99.00 PM18 151.00 151.00 PM19 149.00 149.00 PM20 85.00 85.00 PM21 185.25 185.25 PM22 132.50 132.50 PM23 30.50 30.50 PM24 14.75 14.75 PM25 149.00 149.00 PM26 201.50 201.50 PM27 170.00 170.00 PM28 82.50 82.50 Overall Total Wall Areas (Sq Ft)3,212.75 Exposed Wall Area (Sq Ft)3,021.50 % of Exposed Wall (Exposed / Total)94.05% Proposed Main Level Floor Area Calculations Main Level Gross Floor Area (Sq Ft)2,890.75 Main Level Exempt (Open to Below / T.O. Circulation)210.50 Main Level After Exemptions (Sq Ft)2,680.25 2720.50-119.25 Main Level Countable Interior Floor Area (Sq Ft)2,520.70 Main Level Area x Percent Exposed @ 94.05% Front Porch Gross Floor Area (Sq Ft)228.75 Exempt Front Porch Main Deck Gross Floor Area ( Sq Ft)778.50 Main Level Patio Floor Area (Sq Ft)461.00 Total Proposed Floor Area Calculations Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Interior Floor Area (Sq Ft)4,302.07 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.07 Basement Level Floor Area (Sq Ft)213.15 Lower Level Floor Area (Sq Ft)1,256.03 Main Level Floor Area (Sq Ft)2,497.74 ADU Floor Area (Sq Ft)369.14 Total Existing Interior Floor Area (Sq Ft)4,336.07 Total Existing Deck Area Calculations Main Level Deck Area (Sq Ft)780.50 Exempt Deck Area based on 15% Allowable FAR (NA)0.00 3,966.92 x 0.15 Countable Deck Floor Area (Sq Ft)0.00 Total Existing Countable Floor Area 4,336.07 Basement Level Floor Area (Sq Ft)157.52 Lower Level Floor Area (Sq Ft)1,623.86 Main Level Floor Area (Sq Ft)2,520.70 ADU Floor Area (Sq Ft)0.00 Total Proposed Interior Floor Area (Sq Ft)4,302.08 Total Proposed Deck Area Calculations Main Level Deck Area (Sq Ft)778.50 Exempt Deck Area based on Existing Countable Deck 780.50 Countable Deck Floor Area (Sq Ft)0.00 Total Proposed Floor Area 4,302.08 Total Proposed Floor Area Calculations NOTE: The structure exists as a legally permitted nonconformity. Proposed house to retain current measured floor area per the plans. Total Existing Floor Area Calculations W/ ADU (TOTAL ALLOWABLE FLOOR AREA) 0 4'8'16'SCALE: 1/8" = 1'-0"2 PROPOSED MAIN LEVEL EXPOSURE 0 4'8'16'SCALE: 1/8" = 1'-0"1 PROPOSED MAIN LEVEL FLOOR AREA EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 2'-0"5'-6"13'-6"28'-0"18'-0"9'-2"8'-10" 2'-0" 6'-6" 3'-6" 16'-0" 5'-6" 8'-0" 5'-6" 2'-0" 4'-0" T.O. FF 79'-0" T.O. SLAB 78'-9" SIDE YARD SETBACK S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE P R O P E R T Y L I N E MECH HALL BATH CLO. BEDROOM 5 BATH BEDROOM 6 CRAWL SPACE 1 A-201 2 A-201 3 A-202 4 A-202 9 9 EXISTING EGRESS WELL TO BE REMOVED AND RELOCATED EXISTING EGRESS WELL TO BE REMOVED AND RELOCATED BEDROOM 4 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I N 0 4'8'12'SCALE: 3/16" = 1'-0"1 EXISTING BASEMENT LEVEL PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-102X EXISTING BASEMENT LEVEL PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 2'-0"5'-6"13'-6"28'-0"18'-0"9'-2"8'-10" 4'-0" 2'-0" 5'-6" 8'-0" 5'-6" 16'-0" 3'-6" 6'-6" 2'-0" T.O. FF 89'-7" T.O. GARAGE LEVEL PATIO (VIF) 89'-4" T.O. DRIVEWAY AT GARAGE (VIF) 89'-4" FRONT PORCH ABOVE PATIO ABOVE EGRESS WELL TO BE REMOVED AND RELOCATED EGRESS WELL TO BE RECONFIGURED UP DN SIDE YARD SETBACK S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE P R O P E R T Y L I N E GARAGE MUD GALLERY STUDY / BEDROOM MEDIA VESTIBULELAUNDRY GUEST MASTERBATH BATH CRAWL SPACE 1 A-201 2 A-201 3 A-202 4 A-202 9 9 NOTE: ALL INTERIOR WALLS INDICATED THIS LEVEL TO BE RECONFIGURED TO NEW LAYOUT THAT MEETS CURRENT EGRESS REQUIREMENTS EGRESS WELL TO BE REMOVED AND RELOCATED SITE WALL TO BE REMOVED 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I N 0 4'8'12'SCALE: 3/16" = 1'-0"1 EXISTING GARAGE (MIDDLE) LEVEL PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-103X EXISTING GARAGE LEVEL PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND FF 2'-0"5'-6"13'-6"28'-0"18'-0"9'-2"8'-10" 2'-0" 6'-6" 3'-6" 16'-0" 5'-6" 8'-0" 5'-6" 2'-0" 4'-0" T.O. FINISH FLOOR 100'-3" T.O. PLY 100'-0"T.O. DECK (VIF) 100'-2" T.O. DECK 100'-2"T.O. PATIO (VIF) 100'-2" T.O. PATIO (VIF) 100'-2" T.O. FINISH FLOOR 94'-8" T.O. FRONT PORCH (VIF) 94'-6" 1 A-201 2 A-201 3 A-202 4 A-202 EXISTING ROOF AND WALLS SURROUNDING EXISTING DECK TO BE REMOVED, EXISTING DECK TO BE REMOVED AND ENCLOSED GARAGE ROOF APRON TO BE REMOVED EGRESS WELL TO BE REMOVED AND RELOCATED EGRESS WELL TO BE RECONFIGURED DN DN SIDE YARD SETBACK S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE P R O P E R T Y L I N E PWDER MASTER BATH 202 CLOSET 203 CLOSET 204 DINING ROOM 201 FAMILY ROOM 208 GREAT ROOM 209 ENTRY 210 MASTER BEDROOM 205 GREAT ROOM 209 9 9 RG 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I EXISTING PATIO TO BE REMOVED EXISTING DECK TO BE REFINISHED EXISTING DECK TO BE REMOVED FRONT PORCH TO BE RECONFIGURED EXISTING ADU TO BE REPLACED BY NEW GARAGE SOME WALLS TO REMAIN EGRESS WELL TO BE REMOVED AND RELOCATED KITCHEN 207 N 0 4'8'12'SCALE: 3/16" = 1'-0"1 EXISTING MAIN LEVEL PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-104X EXISTING MAIN LEVEL PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL PROPOSED STANDING SEAM ROOF EXISTING STRUCTURE TO BE REFINISHED WITH SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE EXISTING SHAKE ROOF TO BE REFINISHED EXISTING STRUCTURE TO BE REFINISHED WITH STANDING SEAM METAL ROOF MATERIAL LEGEND PROPOSED SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE T.O. RIDGE (VIF) 122'-23/4" T.O. RIDGE (VIF) 118'-93/4" T.O. RIDGE (VIF) 118'-51/2" EXISTING ROOFS AT THE CURRENT DINING AND EXTERIOR DECK AREA TO BE REMOVED EXISTING ROOFS AT THE CURRENT DINING AND EXTERIOR DECK AREA TO BE REMOVED EXISTING ROOFS AT THE CURRENT DINING AND EXTERIOR DECK AREA TO BE REMOVED 13:1213:12 10:12 10:12 4:12 8:12 13:12 13:12 10:12 SIDE YARD SETBACK S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE P R O P E R T Y L I N E 9 9 T.O. RIDGE (VIF) 118'-51/2" 4 4 6 6 7 7 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I T.O. RIDGE (VIF) 119'-93/4" T.O. STONE CAP (VIF) 125'-5" T.O. STONE CAP (VIF) 123'-1" EXISTING ROOF STRUCTURE TO REMAIN 10:12 10:12 10:12 10:12 13:12 N 0 4'8'12'SCALE: 3/16" = 1'-0"1 EXISTING ROOF PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-105X EXISTING ROOF PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 2'-0"5'-6"13'-6"4'-111/2"23'-01/2"18'-0"9'-2"8'-10"5'-0"22'-41/2" 4'-0" 2'-0" 5'-6" 8'-0" 5'-6" 16'-0" 3'-6" 6'-6" 2'-0" 3'-101/2" 8'-101/2" T.O. FF 79'-0" T.O. SLAB 78'-9" 43 4343 43 43 NEW ELEVATOR UP PROPOSED ADDITIONPROPOSED RENOVATION STAIR 001 STAIR 001 GYM 002 BATH 003 MECH 004 GAME ROOM 006 BEDROOM 008 BATH 005 BATH 017 BEDROOM 018 BEDROOM 020 BATH 021 HALL 022 POWDER 023 BATH 011 BEDROOM 007 VESTIBULE 019 CRAWL SPACE CLO. 010 HALL 009 BATH 012 BATH 011 BEDROOM 014 LAUNDRY 015 MECH 016 1 A-201 2 A-201 3 A-202 4 A-202 9 9 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L N 0 4'8'12'SCALE: 3/16" = 1'-0"1 PROPOSED BASEMENT LEVEL PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-102 PROPOSED BASEMENT LEVEL PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL 4'-0" 2'-0" 5'-6" 8'-0" 5'-6" 16'-0" 3'-6" 6'-6" 2'-0" 3'-101/2" 8'-101/2" 2'-0"5'-6"13'-6"4'-111/2"23'-01/2"18'-0"9'-2"8'-10"5'-0"22'-41/2" T.O. FF 89'-7" T.O. PLY 89'-4" T.O. ENTRY PATIO 89'-7" T.O. GARAGE SLAB 89'-4" 43 43 4343 1643 1643 PROPOSED ELEVATOR UP PROPOSED ADDITIONPROPOSED RENOVATION FRONT PORCH ABOVE PATIO ABOVE STAIR 101 REC ROOM 102 BEDROOM 103 BATHROOM 104 NANNY ROOM 108 BATHROOM 107 BEDROOM 110 MUDROOM 115 BATH 112 BEDROOM 113 POWDER 117 BEDROOM 119 WET ROOM 105 WC 106 BATH 111 ENTRY 118 GARAGE 120 CLOSET 114VESTIBULE 109 GARAGE 116 CLO. 120 BATH 121 CRAWL SPACE 1 A-201 2 A-201 3 A-202 4 A-202 9 9 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N 0 4'8'12'SCALE: 3/16" = 1'-0"1 PROPOSED GARAGE (MIDDLE) LEVEL PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-103 PROPOSED GARAGE LEVEL PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL FF 2'-0"5'-6"13'-6"4'-111/2"23'-01/2"18'-0"9'-2"8'-10"5'-0"22'-41/2" 4'-0" 2'-0" 5'-6" 8'-0" 5'-6" 16'-0" 3'-6" 6'-6" 2'-0" 3'-101/2" 8'-101/2" T.O. FF 100'-3" T.O. PLY 100'-0" T.O. PORCH FINISH 94'-33/4" T.O. ROOF DECK FINISH 100'-3" T.O. PROPOSED PATIO 99'-9" T.O. PATIO 100'-3" 1 A-201 2 A-201 3 A-202 4 A-202 4343 4343 43 43 43 32 PROPOSED ROOF OVER AUTO COURT ENTRY MOVABLE OUTDOOR KITCHEN EQUIPMENT PLANTER AT EDGE OF AUTO COURT, BELOW FRONT PORCH PER RDS PROPOSED PATIO TO BE WITHIN 30" OF FINISHED GRADE 4343 4343 43 43 32 32 PROPOSED ROOF OVER AUTO COURT ENTRY MOVABLE OUTDOOR KITCHEN EQUIPMENT PLANTER AT EDGE OF AUTO COURT, BELOW FRONT PORCH PER RDS PROPOSED PATIO TO BE WITHIN 30" OF FINISHED GRADE PROPOSED PATIO PROPOSED ROOF DECK DW AUTOCOURT BELOW PROPOSED PATIO PROPOSED PATIO PROPOSED ROOF DECK DW AUTOCOURT BELOW DN PROPOSED PATIO 9 9 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L RG PLANTER AT ROOF DECKPLANTER AT ROOF DECK KITCHEN 212 BREAKFAST 213 LIVING ROOM 214 DINING ROOM 202 MASTER BEDROOM 209 MASTER BATH 205 CLOSET 208 CLOSET 207 WC 206 LAUNDRY 204 STAIR 201 POWDER 203 PANTRY 211 EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND N 0 4'8'12'SCALE: 3/16" = 1'-0"1 PROPOSED MAIN LEVEL PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-104 PROPOSED MAIN LEVEL PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL T.O. RIDGE 122'-23/4" T.O. RIDGE 119'-93/4" T.O. RIDGE 118'-51/2" T.O. PORCH ROOF AT EDGE 101'-73/4" T.O. PORCH ROOF AT EDGE 98'-11" T.O. RIDGE 116'-31/4" 13:1213:12 10:12 10:12 8:12 13:12 13:12 10:12 2:12 2:12 2:12 2:12 2:12 6:12 6:12 SIDE YARD SETBACK S I D E Y A R D S E T B A C K REAR YARD SETBACK FRONT YARD SETBACK PROPERTY LINE P R O P E R T Y L I N E T.O. RIDGE 119'-93/4" 9 9 T.O. RIDGE 118'-51/2" 4 4 6 6 7 7 10 10 5 5 8 8 1 1 C C B B A A D D E E F F G G H H J J 2 2 3 3 I I 11 11 K K L L T.O. PERGOLA 111'-21/2" T.O. CHIMNEY CAP 123'-6" T.O. STONE CAP (VIF) 123'-1" T.O. STONE CAP 113'-11/4" EXISTING ROOF STRUCTURE TO REMAIN 10:12 10:12 10:12 10:12 13:12 PROPOSED FRONT PORCH ROOF PROPOSED HIP ROOF PROPOSED ROOF EXTENSION PROPOSED STANDING SEAM ROOF EXISTING STRUCTURE TO BE REFINISHED WITH SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE EXISTING SHAKE ROOF TO BE REFINISHED EXISTING STRUCTURE TO BE REFINISHED WITH STANDING SEAM METAL ROOF MATERIAL LEGEND PROPOSED SINGLE PLY SELF ADHERING WATERPROOF MEMBRANE N 0 4'8'12'SCALE: 3/16" = 1'-0"1 PROPOSED ROOF PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-105 PROPOSED ROOF PLAN 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL 6 7 948123 28'-1" VIF 10'-7" 10'-8" 10'-9" 9'-03/4" 2'-5" EXISTING MASTER BEDROOM WING TO REMAIN, EXTERIOR FINISHES TO BE REPLACED T.O. PLATE 110'-9" T.O. MAIN LEVEL FLOOR STRUCTURE 100'-0" T.O. GARAGE LEVEL FLOOR STRUCTURE 89'-4" T.O. BASEMENT LEVEL FLOOR STRUCTURE 78'-9" FRONT SETBACK MASTER BEDROOM WING TO REMAIN, EXTERIOR FINISHES TO BE REPLACED ALL STRUCTURAL CHANGES TO OCCUR TO THE RIGHT OF THE DASHED LINE RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" 12 10 12 13 12 13 12 13 12 13 12 13 J I H G F E D C B A 15'-71/2" VIF 10'-7" 10'-8" 10'-9" 7'-81/2" 3'-91/4" EXISTING MASTER BEDROOM WING TO REMAIN, STONE AND ROOF FINISHES TO BE REPLACED RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 118'-5 1/2" T.O. PLATE 110'-9" T.O. MAIN LEVEL FLOOR STRUCTURE 100'-0" T.O. GARAGE LEVEL FLOOR STRUCTURE 89'-4" T.O. BASEMENT LEVEL FLOOR STRUCTURE 78'-9" 12 13 12 13 12 13 12 13 0 4'8'12'SCALE: 3/16" = 1'-0"1 EXISTING NORTHWEST ELEVATION 0 4'8'12'SCALE: 3/16" = 1'-0"2 EXISTING NORTHEAST ELEVATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-201X EXISTING ELEVATIONS 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL 8 69 4 3 2 17 10'-7" 10'-8" 10'-9" 9'-03/4" 2'-5" EXISTING MASTER BEDROOM WING TO REMAIN, STONE AND ROOF FINISHES TO BE REPLACED ADU TO BE REMOVED, SOME WALLS TO REMAIN ROOF FINISH TO BE REPLACED WITH STANDING SEAM METAL NEW EXTERIOR DOORS TO ACCESS NEW PATIO AT GRADE 21 20 21 18 T.O. PLATE 110'-9" T.O. MAIN LEVEL FLOOR STRUCTURE 100'-0" T.O. GARAGE LEVEL FLOOR STRUCTURE 89'-4" T.O. BASEMENT LEVEL FLOOR STRUCTURE 78'-9" FRONT SETBACK 12 10 12 13 12 13 12 13 12 13 12 13 FRONT SETBACK MASTER BEDROOM WING TO REMAIN, EXTERIOR FINISHES TO BE REPLACED ALL STRUCTURAL CHANGES TO OCCUR TO THE LEFT OF THE DASHED LINE RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" A B C D E F G H I J 10'-7" 10'-8" 10'-9" 9'-03/4" 2'-5" 32'-103/4" VIF T.O. PLATE 110'-9" T.O. MAIN LEVEL FLOOR STRUCTURE 100'-0" T.O. GARAGE LEVEL FLOOR STRUCTURE 89'-4" T.O. BASEMENT LEVEL FLOOR STRUCTURE 78'-9" RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" 12 10 12 10 12 10 0 4'8'12'SCALE: 3/16" = 1'-0"3 EXISTING SOUTHEAST ELEVATION 0 4'8'12'SCALE: 3/16" = 1'-0"4 EXISTING SOUTHWEST ELEVATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-202X EXISTING ELEVATIONS 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL 5 6 7 94 108123 11 10'-7" 4'-93/4" 5'-101/4" 10'-9" 5'-61/4" 3'-61/2" 2'-5" 7'-0" ENTRY DOOR HEIGHT 14'-111/2" 28'-1" VIF 17 21 19 20 EXISTING MASTER BEDROOM WING TO REMAIN, EXTERIOR FINISHES TO BE REPLACED 56 23 15 13 14 56 23 12 10 11 48 35 36 09 08 20 21 18 RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" T.O. PLATE 110'-9" T.O. PLY AT MAIN LEVEL 100'-0" T.O. PLY AT GARAGE LEVEL 89'-4" T.O. SLAB AT BASEMENT 78'-9" FRONT SETBACK MASTER BEDROOM WING TO REMAIN, EXTERIOR FINISHES TO BE REPLACED ALL STRUCTURAL CHANGES TO OCCUR TO THE RIGHT OF THE DASHED LINE T.O. SLAB AT FRONT PORCH 94'-13/4" 12 13 12 10 12 13 12 13 12 13 12 13 12 13 12 13 12 2 12 2 RIDGE HEIGHT 113'-31/4" L K J I H G F E D C B A 10'-7" 10'-8" 10'-9" 7'-81/2" 3'-91/4" 21 20 17 23 19 21 23 EXISTING MASTER BEDROOM WING TO REMAIN, STONE AND ROOF FINISHES TO BE REPLACED T.O. PLATE 110'-9" T.O. MAIN LEVEL FLOOR STRUCTURE 100'-0" T.O. GARAGE LEVEL FLOOR STRUCTURE 89'-4" T.O. BASEMENT LEVEL FLOOR STRUCTURE 78'-9" RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" RIDGE HEIGHT 118'-51/2" 12 13 12 13 12 13 12 13 0 4'8'12'SCALE: 3/16" = 1'-0"1 PROPOSED NORTHWEST ELEVATION 0 4'8'12'SCALE: 3/16" = 1'-0"2 PROPOSED NORTHEAST ELEVATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-201 PROPOSED ELEVATIONS 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL 8 611109 5 4 3 2 17 2'-6" 3'-2" 10'-7" 10'-8" 10'-9" 5'-61/4" 2'-21/4" 1'-41/4" 2'-5" 17 21 19 20 EXISTING MASTER BEDROOM WING TO REMAIN, STONE AND ROOF FINISHES TO BE REPLACED 56 23 53 STEEL SHADE STRUCTURE, > 50% OPEN TO ABOVE NEW EXTERIOR DOORS TO ACCESS NEW PATIO AT GRADE 21 20 21 3131 20 18 T.O. PLATE 110'-9" T.O. MAIN LEVEL FLOOR STRUCTURE 100'-0" T.O. GARAGE LEVEL FLOOR STRUCTURE 89'-4" T.O. BASEMENT LEVEL FLOOR STRUCTURE 78'-9" FRONT SETBACK RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" RIDGE HEIGHT 118'-51/2"12 10 12 13 12 13 12 13 12 13 12 13 FRONT SETBACK MASTER BEDROOM WING TO REMAIN, EXTERIOR FINISHES TO BE REPLACED ALL STRUCTURAL CHANGES TO OCCUR TO THE LEFT OF THE DASHED LINE RIDGE HEIGHT 116'-31/4" RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" A B C D E F G H I J K L 10'-7" 10'-8" 10'-9" 9'-03/4" 2'-5" 8'-0" 30'-23/4" 2'-5" 13 14 15 17 21 19 20 23 3131 48 23 53 35 49 36 36 08 20 21 36 T.O. PLATE 110'-9" T.O. MAIN LEVEL FLOOR STRUCTURE 100'-0" T.O. GARAGE LEVEL FLOOR STRUCTURE 89'-4" T.O. BASEMENT LEVEL FLOOR STRUCTURE 78'-9" RIDGE HEIGHT 122'-23/4" RIDGE HEIGHT 119'-83/4" 12 10 12 10 12 10 12 10 0 4'8'12'SCALE: 3/16" = 1'-0"3 PROPOSED SOUTHEAST ELEVATION 0 4'8'12'SCALE: 3/16" = 1'-0"4 PROPOSED SOUTHWEST ELEVATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 DRIVEWAY PER CITY ORD 66 SECTION 1 NEW CITY DRAINAGE PIPE PER CIVIL ENG SLOPE TO BE RE-VEGETATED PER RESOLUTION NO 12 SERIES OF 2013 UNCOVERED PATIO / SLABS <30" ABOVE GRADE PER 26.575.020.E.5.k SITE RETAINING WALL <30" ABOVE GRADE PER 26.575.020.E.5.k ROOF EAVE <18" PROJECTION PER 26.575.020.E.5.g PRINCIPAL WINDOW PER RDS 26.410.030.E.1.D.1 WINDOW PLACEMENT PER RDS 26.410.030.E.2.C R-6 ZONE DISTRICT HEIGHT LIMIT 25' CHIMNEY PROJECTION <10' FROM HEIGHT OF BUILDING CONNECTION PER 26.575.020.F.4.a EXTERIOR LIGHTING TBD 1/3 POINT FROM EAVE TO RIDGE FLAT ROOF, SLOPED 1/4" PER 1' FOR DRAINAGE NEW STONE COLUMN BASE INTERPOLATED SLOPE USED FOR HEIGHT CALCULATION FULL WIDTH STONE VENEER TBD WOOD RAINSCREEN TBD WINDOW TRIM TBD CLASS B MASONRY ROOF SHINGLE PER ARCH MECHANICAL PROJECTIONS <5' ABOVE HEIGHT OF ROOF PER 26.575.020.F.4.e EXISTING GAS FIREPLACE APPLIANCE TO REMAIN NON-COMBUSTIBLE FRAMING, TYP LIGHTWELL PER IRC 310.2 SNOWMELT PER IRC 310 LIFE + SAFETY WOOD HEADER + MASONRY SILL PER ARCH LINE OF EXTERIOR WALL BELOW AC UNITS GAS + ELECTRIC METERS NEW TIMBER COLUMN HANDRAIL PER IRC 312.2 MIN HEIGHT 34" GLASS GUARD SAFETY GLAZED PER 308.4 + SUPPORT POINT LOAD PER 301.5 EXISTING CHIMNEY TO BE REFINISHED BUT REMAIN WINDOW WELL PANEL TO BE NON-LOCKING FLIP-UP GRATE AND REQUIRE NO MORE THAN 15 LBS OF FORCE TO OPEN; TYP GARAGE / DWELLING FIRE SEPARATION PER IRC R302.6; TYP SLOPE 1/4" PER 1' FOR DRAINAGE ROOF OVERHANG SEWAGE EJECTOR ACCESS LOCATION ELECTRICAL PANEL LOCATION EGRESS SILL 3'-6" AFF BUILT-IN MILLWORK RADON VENT PIPE SNOW STOPS / SNOW FENCE DOWNSPOUT EXHAUST FLUE VENT; TYP GUTTER EXISTING GRADE STONE CHIMNEY CAP STANDING SEAM METAL ROOF ROOF DECK MATERIAL TBD EXTERIOR RAILING MATERIAL TBD PATIO MATERIAL TBD DRIVEWAY MATERIAL TBD DECORATIVE STEEL, PER STRUCT SIDE-LOADED GARAGE PER RDS 26.410.030.C.2.D.2 GARAGE DOOR PER RDS 26.410.030.C.4.D.2 OPEN FRONT PORCH PER RDS 26.410.030.D.1.D.2 FRONT DOOR PER RDS 26.410.030.D.2.C ENTRY PORCH HEIGHT PER RDS 26.410.030.D.3.C NON-ORTHOGONAL WINDOW PER 26.410.030.E.3.C LIGHT WELL PER RDS 26.410.030.E.4.C BUILDING MATERIALS PER RDS 26.410.030.E.5.C LINE OF FOUNDATION WALL BELOW PROPOSED GRADE STUCCO TBD RETAINING WALL EXTERIOR GUARDRAIL PER R311.7.7 LINE OF EXISTING FOUNDATION LINE OF ROOF ABOVE MECH / FIREPLACE CHASE PATIO SNOWMELT PER IBC 1140.1 INFLECTION CODE RDS.E.2 WILDLIFE-RESISTANT TRASH ENCLOSURE PER 26.575.020.E.5.t STONE PLANTER COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DATE OF PUBLICATION A-202 PROPOSED ELEVATIONS 7/7/20 FOR UMPHI KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC NOT FOR CONSTRUCTION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE PRE-APP SUBMITTAL 01/13/20 05/01/20 07/07/20 CONCEPTUAL HPC SUBMITTAL HPC CONTINUANCE SUBMITTAL COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-203 STREETSCAPE ELEVATIONS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 56'-3"15'-3"6'-9"5'-51/8" 15'-103/4" 78'-3" HISTORIC RESOURCE 114 NEALE AVE INTERSECTION OF PROPERTY LINE AT STREET ALL ABOVE GRADE WORK TO OCCUR TO THE RIGHT OF THE RED LINE PROJECT SITE 110 NEALE AVE 25' HEIGHT LIMIT 56'-3"15'-3"6'-11"7'-33/4"6'-55/8" 78'-3" INTERSECTION OF PROPERTY LINE AT STREET HISTORIC RESOURCE 114 NEALE AVE PROJECT SITE 110 NEALE AVE 0 4'8'16'SCALE: 1/8" = 1'-0"2 PROPOSED NEALE AVE ELEVATION 0 4'8'16'SCALE: 1/8" = 1'-0"1 EXISTING NEALE AVE ELEVATION COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-204 PERSPECTIVE EXTERIOR VIEWS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 1 NEALE STREET ELEVATION COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-205 PERSPECTIVE EXTERIOR VIEWS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 1 NORTH VIEW 2 EAST VIEW COPYRIGHT PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-206 PERSPECTIVE EXTERIOR VIEWS 7/7/20 KP, BF 1911.00 ASPEN, CO 81611 110 NEALE AVE 17 QUEEN LLC FOR UMPHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 N. 4th St. Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 DRAWING ISSUANCE INDEX ID NAME ISSUED DATE NOT FOR CONSTRUCTION PRE-APP SUBMITTAL 01/13/20 CONCEPTUAL HPC SUBMITTAL 05/01/20 HPC CONTINUANCE SUBMITTAL 07/07/20 1 WEST VIEW 2 SOUTH VIEW Drainage Report 110 NEALE AVENUE ASPEN, CO 81611 May 27, 2020 Prepared by Richard Goulding, P.E. Roaring Fork Engineering 592 Highway 133 Carbondale, CO 81623 Drainage Report 110 NEALE AVENUE ASPEN, CO 81611 I HEREBY AFFIRM THAT THIS REPORT FOR THE IMPROVEMENTS AT 110 NEALE AVENUE WAS PREPARED BY ME FOR THE OWNERS THEREOF IN ACCORDANCE WITH THE PROVISIONS OF CITY OF ASPEN AND APPROVED VARIANCES AND EXCEPTIONS LISTED THERETO. I UNDERSTAND THAT IT IS THE POLICY OF THE CITY OF ASPEN THAT ASPEN DOES NOT AND WILL NOT ASSUME LIABILITY FOR DRAINAGE FACILITIES DESIGNED BY OTHERS. RICHARD GOULDING, P.E. RFE Project # 2020-13 Table of Contents 1.0 General ................................................................................................................................. 4 1.1 Existing Site ..................................................................................................................... 4 1.2 Proposed Site .................................................................................................................... 4 1.3 Previous Drainage Studies ............................................................................................... 5 1.4 Offsite Drainage ............................................................................................................... 5 2.0 Drainage Basins and Sub-basins .......................................................................................... 5 2.1 Drainage Basins................................................................................................................ 5 2.2 Peak Discharge Calculations ............................................................................................ 6 3.0 Low Impact Site Design....................................................................................................... 7 3.1 Principles .......................................................................................................................... 7 4.0 Hydrological Criteria ........................................................................................................... 8 4.1 Storm Recurrence and Rainfall ........................................................................................ 8 4.2 Storage Volumes Methodology ........................................................................................ 8 5.0 Hydraulic Criteria ................................................................................................................ 9 6.0 Proposed Facilities ............................................................................................................... 9 6.1 Drywell ............................................................................................................................. 9 7.0 Operation and Maintenance ................................................................................................. 9 7.1 Inlets and Piping ............................................................................................................... 9 7.2 Drywell ........................................................................................................................... 10 8.0 Appendices ......................................................................................................................... 10 8.1 Drainage Basin Map ....................................................................................................... 10 8.2 Previous Drainage Study by Boundaries Unlimited ...................................................... 10 4 1.0 General 1.1 Existing Site The following report is an evaluation of the proposed redevelopment of the existing residence at 110 Neale Avenue in Aspen, Colorado, parcel number 273707383002. The property is located at the Southeast corner of the intersection at Neale Avenue and Queen Street, and is surrounded by other residential lots and open space to the south. The site contains a single-family residence with an approximate footprint of 1,220 square feet. The site has extensive flagstone hardscaping, large existing cottonwoods and maple trees, and an access driveway accessing Queen Street. There are neighboring properties with single-family residences located to the east and north, with street right of way to the south and west. The existing topography is sloped with an average 10% grade from the north to the south, following Neale Avenue. An existing conditions sheet has been included in the submitted drawings. Figure 1: Pitkin County GIS vicinity view. Parcel 273707383002 shown in red. 1.2 Proposed Site This project is classified as a ‘Major Project’ per Table 1.1. of the City of Aspen Urban Runoff Management Plan (URMP). The proposed development is over 1,000 square feet and disturbs an area that exceeds 25% of the entire site. The intent of this report is to demonstrate compliance with the requirements of the URMP. The Low Impact Design (LID) Principles in the introduction of the manual were used as a guide throughout the design process. Onsite storm infrastructure has been sized to convey runoff for a 100-year storm event. 5 The proposed project will be a comprehensive remodel of the entire site. The existing residence foundation will remain in its existing location, but the basement will be expanded below the structure. A new garage structure, above grade additions to the residence and new roofs will be constructed. Landscaping, patios, and walkways are proposed around the site, and the driveway will be removed and replaced with landscaping. The proposed drainage infrastructure includes downspouts from roof structures, trench drains within hardscaped areas, and area drains surrounding the site capture on-site flows before they reach the adjacent properties and Aspen right-of-way. All onsite drainage is captured from impervious areas and is routed through an onsite pipe system that connects to an existing drywell system. Per previous drainage studies, the drywell system is sufficient for the proposed design. All existing drainage structures will be inspected before building permit submittal. Improvements will be made to the right of way, including new sidewalk and curb and gutter along Queen Street. All updates are in regards to meeting the City of Aspen Engineering Design Standards. 1.3 Previous Drainage Studies The City of Aspen updated their URMP in 2001 and the property is within the boundaries of the study. The study indicates that the property is not within a Mudflow area. A previous drainage report prepared by Boundaries Unlimited in 2005 for the existing residence is included in this report. 1.4 Offsite Drainage No offsite basins affect the site, so no analysis was required. 2.0 Drainage Basins and Sub-basins The development on the parcel is proposed as one large onsite basin. This basin will be subdivided into smaller sub-basins and analyzed to aid with design of the storm water infrastructure for the permit submittal. Basin delineation is shown on sheet C3 of the HPC submittal. This sheet lists impervious area, runoff coefficients, peak flows, and the required volume of runoff to be detained. 2.1 Drainage Basins Basin 1 is a major basin within the parcel and consists of the developed area of the residence, including the concrete driveway, impervious walkways, pervious walkways, and the roof. The basin has a total area of 12,990 square feet and is 60% impervious. The remaining pervious areas of the basin include several landscaped areas surrounding the residence. Runoff from the basin is collected through trench drains, area drains, and downspouts from the roof. The captured runoff is then conveyed through the piping system to an existing drywell system to the south of the site that is sized for full detention. This system will be examined before permit submittal. 6 2.2 Peak Discharge Calculations The peak flows were calculated for the Major Onsite Basin for the 5-year and 100-year storm event using the Rational Method. The Rational Method is an acceptable method to calculate runoff for this basin as the area is under 90 acres. Rainfall intensity was calculated using a Time of Concentration (Td) of 5 minutes. The actual time of concentration for this site is less than 5 minutes, but according to the City of Aspen URMP, equations used to calculate rainfall intensity are only valid for a time of concentration of 5 minutes or greater, so the smallest valid time of concentration value was used. The 1-hour Rainfall depths (P1) used for these calculations were taken from Table 2.2 of the URMP and are equal to 0.64 inches for the 5-year event and 1.23 inches for the 100-year event. Equation 2.1 was referenced when solving for the Rainfall Intensity (I). 𝑰𝑰= 𝟖𝟖𝟖𝟖.𝟖𝟖 𝑷𝑷𝟏𝟏(𝟏𝟏𝟏𝟏+𝑻𝑻𝒅𝒅)𝟏𝟏.𝟏𝟏𝟎𝟎𝟎𝟎 (𝐸𝐸𝐸𝐸.2.1) Runoff Coefficients (C), a function of the Soil Group (in this case B for the basins) and the percentage of impervious area were developed using Figure 3.3. The Runoff Coefficient (C) was then multiplied by the Rainfall Intensity (I) and the area of the calculated basin (A, in acres) to determine the peak discharge. 𝑸𝑸𝒑𝒑=𝑪𝑪𝑰𝑰𝑪𝑪 𝑄𝑄𝑝𝑝=𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃 𝐷𝐷𝐷𝐷𝐷𝐷𝐷𝐷ℎ𝑃𝑃𝑎𝑎𝑎𝑎𝑃𝑃 (𝐷𝐷𝑐𝑐𝐷𝐷) 𝐶𝐶=𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑐𝑐𝑐𝑐 𝐶𝐶𝑅𝑅𝑃𝑃𝑐𝑐𝑐𝑐𝐷𝐷𝐷𝐷𝐷𝐷𝑃𝑃𝑅𝑅𝐶𝐶 𝐼𝐼=𝑅𝑅𝑃𝑃𝐷𝐷𝑅𝑅𝑐𝑐𝑃𝑃𝑅𝑅𝑅𝑅 𝐼𝐼𝑅𝑅𝐶𝐶𝑃𝑃𝑅𝑅𝐷𝐷𝐷𝐷𝐶𝐶𝐼𝐼 (𝐷𝐷𝑅𝑅𝐷𝐷ℎ𝑃𝑃𝐷𝐷 𝑝𝑝𝑃𝑃𝑎𝑎 ℎ𝑅𝑅𝑅𝑅𝑎𝑎) 𝐴𝐴=𝐴𝐴𝑎𝑎𝑃𝑃𝑃𝑃 (𝑃𝑃𝐷𝐷𝑎𝑎𝑃𝑃𝐷𝐷) These peak flow values were used to calculate the size of the proposed detention and conveyance structures, such as the drywell, inlets and pipes. The tables below contain the peak flows for developed and undeveloped conditions for 5-year and 100-year storm events for the major basin, and the 100-year peak flow rate for the sub basins. 5 Year Peak Discharge Developed Calculations 1 Hour(P 1)0.64 Return Period 5 Basin ID Total Area Imp. Area Impervious C Value Time of C Intensity Q Max See(D1)(ft2)(ft2)(%)From Table (Td)I=88.8P1/(10+Td)1.052 (ft3/sec) 1 12990.00 7856.00 60.48%0.410 5 3.29 0.40 5 Year Peak Discharge Pre Development Calculations 1 Hour(P 1)0.64 Return Period 5 Basin ID Total Area Imp. Area Impervious C Value Time of C Intensity Q Max See(D1)(ft2)(ft2)(%)From Table (Td)I=88.8P1/(10+Td)1.052 (ft3/sec) 1 12990.00 0.00 0.00%0.080 5 3.29 0.08 7 3.0 Low Impact Site Design Low Impact Development (LID) aims to mimic the natural pre-development hydrologic pattern. The goal is to manage storm water as close to its source as is possible. This entire developed site is approximately 58% impervious. The treatment train approach is used on all runoff to increase water quality and infiltration. 3.1 Principles Principle 1: Consider storm water quality needs early in the design process. The grading and drainage design was coordinated between the architect and civil engineering teams throughout the design process and water quality requirements were discussed early on. Site visits ensured proper understanding of existing conflicts and opportunities to improve existing drainage patterns. Principle 2: Use the entire site when planning for storm water quality treatment. Storm water quality was considered in the design of every part of the site that is being affected by the proposed construction. Existing infrastructure will be used to the maximum extent possible. Principle 3: Avoid unnecessary impervious area. The total impervious area on the site was kept to a minimum while meeting the architectural design goals. Principle 4: Reduce runoff rates and volumes to more closely match natural conditions. All runoff from impervious surfaces on the property is collected and routed to BMP structures. The infrastructure has been sized to capture the 100-year detention volume water quality capture volume. The drywell is designed to infiltrate storage capacity into the surrounding earth. Principle 5: Integrate storm water quality management and flood control. 100 Year Peak Discharge Developed Calculations 1 Hour(P 1)1.23 Return Period 100 Basin ID Total Area Imp. Area Impervious C Value Time of C Intensity Q Max See(D1)(ft2)(ft2)(%)From Table (Td)I=88.8P 1/(10+Td)1.052 (ft3/sec) 1 12990.00 7856.00 60.48%0.570 5 6.33 1.08 100 Year Peak Discharge Pre Development Calculations 1 Hour(P 1)1.23 Return Period 100 Basin ID Total Area Imp. Area Impervious C Value Time of C Intensity Q Max See(D1)(ft2)(ft2)(%)From Table (Td)I=88.8P 1/(10+Td)1.052 (ft3/sec) 1 12990.00 0.00 0.00%0.350 5 6.33 0.66 8 The proposed drywell will capture and treat runoff for water quality, and the drywell will infiltrate the runoff into the soils, eliminating runoff from the site. Principle 6: Develop storm water quality facilities that enhance the site, the community and the environment. The design is proposing using existing infrastructure for full detention for all stormwater, meaning no runoff will be leaving the site, with no additional concrete stormwater structures on sit. Principle 7: Use treatment train approach. The design implements sheetflow across landscaping, pervious pavers, and sumps in the pipe network to ensure treatment throughout the system. Principle 8: Design sustainable facilities that can be safely maintained. Inlets and piping will be vacuumed or flushed periodically to maintain adequate flow. Proper grading reduces dangerous slopes. Cleanouts are located where necessary to ensure the lifetime of the drainage infrastructure. Principle 9: Design and maintain facilities with public safety in mind. The proposed design for driveway and walkways reduces ice buildup and dangerous conditions. All grading was done with safety in mind, and no steep slopes occur on site. 4.0 Hydrological Criteria 4.1 Storm Recurrence and Rainfall The property is not in the commercial core and is served by any city curb and gutter so this property classifies as a “Sub-urban area served by public storm sewer”. However, due to limitations on the site, the curb and gutter cannot be utilized, so the site cannot disperse into the curb and gutter. Due to this, the 5-year and 100-year events were analyzed. The 1-hour Rainfall depth (P1) is given in Table 2.2 as 0.64 inches for the 5-year event and 1.23 inches for the 100-year event. The Intensity in inches per hour for different storm duration (Td) was calculated using Equation 2.1 from the City of Aspen URMP. 4.2 Storage Volumes Methodology The storage requirements for this site were calculated using the total impervious area along with the historic and developed peak runoff rates that were established in section 2.2. The proposed storm drainage system is designed to discharge into existing drywells for full detention of a 100- year storm event. The existing drywells were inspected and dipped for storage depths. The drywells will be inspected further for functionality prior to permit submittal. The full detention calculations are shown in the following table. 9 5.0 Hydraulic Criteria This property is not connected to the COA’s storm water infrastructure. All hydraulics are sized for onsite infrastructure. The storm system was designed to route all impervious surfaces to the drywell located in the garage. Inlet and pipe sizing have not been performed but will be completed for the permit submittal. Pipe sizes will be tested for hydraulic capacity at 80 percent of their full flowrate for the permit submittal. Design charts giving Qdesign / Q full were downloaded from FHWA and the equations in Section 4.8.4 will be used as the basis for these calculations. Calculated pipe sizes and depth of flow for onsite pipes will be shown for permit submittal. 6.0 Proposed Facilities This property is not connected to the COA’s storm water infrastructure, and the existing drywell system is sized for full detention, as clarified in section 2.2 of this report. Below are the analyses for the individual detention structure’s capacity and infiltration. A previous drainage report for the drywell system is included in this report. 6.1 Drywell Below is a table that shows the existing drywell system meeting the capacity required for full detention of Basin 1. All drywells will be inspected prior to permit submittal. If drywells are no longer functioning, new drywells shall be installed or alternative infiltration methods will be used onsite. A drawdown test will be conducted to determine the performance of the existing drywells. 7.0 Operation and Maintenance 7.1 Inlets and Piping The piping must be maintained periodically to ensure proper operation. Minimum inspection and maintenance requirements include the following: Full Detention Storage Basin Total Area Impervious Area Impervious Full Detention Depth Factor of Safety Required Storage BMP (ft2)(ft2)(%)(in)F.O.S.(ft3) 1 12990.00 7856.00 60.48%1.23 1 805 EX DRYWELL SYSTEM Drywell Storage Drywell Basins Diameter Storage Depth Perforated Depth Internal Volume External (18" of Screened Rock) Volume Total Capacity Required Capacity (Name)(#)D (ft)H (ft)P (ft)π*H*(D/2)2) (ft3)0.3*π*P*((D/2)+1.5)2 - (D/2)2) (ft3)(ft3)(ft3) EX 1 1 6 10 4 283 42 325 273 EX 2 1 6 10 4 283 42 325 273 EX 3 1 6 10 4 283 42 325 273 EX 4 1 6 10 4 283 42 325 273 10 • During the first year draw down should be checked for every event exceeding 0.25” of precipitation to ensure no significant backups are occurring. • Piping systems and sumps should be checked during and after storms routinely. • After the first year, the system should be cleaned out at least once a year and more if the first-year inspection proves more maintenance is required. • More frequent cleaning reduces the amount of debris entering the system and reduces the need for more intense maintenance. • Clean the inside of any perforated pipes with a pipe cleaner accessed through cleanouts. This should be done yearly, or as necessary if the system is not infiltrating properly or if the system has become contaminated. • Ensure heat tape is functioning before colder months to prevent damage to piping. If the storm system is not maintained properly, replacement of parts or of the entire system may be necessary. 7.2 Drywell Drywells must be inspected and maintained quarterly to remove sediment and debris that has washed into them. A maintenance plan shall be submitted to the City in the Drainage Report describing the maintenance schedule that will be undertaken by the owners of the new residence or building. Minimum inspection and maintenance requirements include the following: • Inspect drywells at least four times a year and after every storm exceeding 0.5 inches. • Dispose of sediment, debris/trash, and any other waste material removed from a drywell at suitable disposal sites and in compliance with local, State, and Federal waste regulations. • Routinely evaluate the drain-down time of the drywell to ensure the maximum time of 24 hours is not being exceeded. If drain-down times are exceeding the maximum, drain the drywell via pumping and clean out the percolation area (the percolation barrel may be jetted to remove sediment accumulated in perforations. If slow drainage persists, the system may need to be replaced. 8.0 Appendices 8.1 Drainage Basin Map 8.2 Previous Drainage Study by Boundaries Unlimited C3 DRAINAGE BASINS RO A R I N G F O R K E N G I N E E R I N G 59 2 H I G H W A Y 1 3 3 CA R B O N D A L E C O L O R A D O , 8 1 6 2 3 PH : ( 9 7 0 ) 3 4 0 - 4 1 3 0 F : ( 8 6 6 ) 8 7 6 - 5 8 7 3 CHECKED BY: # DE S C R I P T I O N DA T E D R A W N B Y CONSTRUCTION DRAWN BY: JOB #: Of 5 2020-13 NOT FOR ADW RBG 11 0 N E A L E A V E N U E AS P E N , C O HP C S U B M I T T A L 0 5 / 2 7 / 2 0 2 0 Z U U )0 ; ;200 DRAINAGE STUDY Brien Property; 114 Neale Street ASPEN, COLORADO PROJECT NO. Brien April 12, 2005 Prepared by: BOUNDARIES UNLIMITED INC. 1w Consulting & Civil Engineer R 923 COOPER AVENUE, STE. 702 QPOO• GLENWOOD SPRINGS, CO H TELE: 970.945.5252 / PAx: 970.3H4. 37110 Q DericJ. Walter, F.E. NE Engineer TABLE OF CONTENTS SECTION INTRODUCTION HYDROLOGY DRAINAGE PLAN EROSION CONTROL 00752005 00762005 PAGE FIGURES: 1) SCS Soils Map 2) Grading, Drainage and Erosion Control Site Plans 3) Detail Sheet 4) FEMA Map APPENDIX: Calculations 1 1 1 1 INTRODUCTION O U� 5 2 O O 5 The proposed residential development of the Brien Property is located at the intersection of Neale St. and Queen St. in the City of Aspen, Colorado. The lot is comer" 6f2 0 0 - approximately 15,160 square feet which is currently vacant. HYDROLOGY The hydrologic methods for this study are outlined in the City of Aspen Interim Standards for Drainage Design and Erosion -Sediment Control Practices, the United State Department of Agriculture (USDA) Natural Resources Conservation Service (NRCS) publication "Urban Hydrology for Small Watersheds TR-55" and the computer program AutoCAD Hydrology TR-55 Tabular Method. Site soils consist of Type C soils with a historic vegetative cover of cottonwoods, brushes and grasses in good condition. See the enclosed NRCS Soils Map for hydrologic determinations. According to the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map #080970204C, the building area appears to be outside the 100-yr floodplain (flood elevation of approximately 7896'). Assuming the provided topography is on the same datum as the FEMA map, the proposed building finish floors appear to be above the 100- yr floodplain. See the enclosed FEMA Map. DRA/NAGE PLAN The drainage basin for this study was taken as the property boundary. All stormwater runoff from the proposed buildings will be captured by roof drains and directed to the n proposed drywells along Queen Street. The drywell system should be constructed with 1 overflow swqlpc that overflow into the Queen Street drainage and the Roaring Fork River. Drainage swales should also be constructed along the property boundaries, as necessary, to keep excessive runoffs from flooding the adjacent property on Queen Street. Detention volumes were found 4sing an average of the Rational Formula Hydrograph, Imperical, Federal Aviation -AdrajhLstration and NRCS TR-55 Tabular methods to mitiaa the a ects of the 100-year, 24-ho��r_ s_ t�_.The detention volume required is based on the volume needed to lower the peak from the estimated 1 00-Y r runoff under proposed conditions to match the estimated 1g0-year runoff from the site's natural conditions. The general flow patterns are shown on the enclosed Grading, Drainage and Erosion Control Plan, along with general location of the proposed drywells. Overlot grading must be performed to ensure that drainage is directed away from all structures in all directions. EROSION CONTROL Erosion control measures should be followed during construction to insure that the property, adjacent sites and roadways are not impacted from sedimentation. These measures will include erosion control logs, sediment control fencing, swales and best management practices during construction activities. Page 1 00752005 Figures •00752005 ! 108 . 107I� SPEi 107 I� 108, 10 ` . • 1 SITE co;07 °' s, : 9 _\,I /% 104 - j � � ASPEN �c`aovE , CErdETER Y r 7e, 76 G�\0 1 ( 9 77 I �` 76 I08 o . a m 6; :o 0 0 Q SOIL TYPE 92: Redrob Loam (deep, poorly drained, moderate permeability Soil Type C) 0 a c v m 0 0 Boundaries Unlimited, Inc. SCALE:1^=2000' Alice Brien 923 Cooper Avenue, Ste. 102 Glenwood Springs, DATE: 4/12/05 Aspen, Colorado 114 Neale Co 81601 FILE: GR-01 St. tele: 970.945.5252 fax: 970.384.2833 SHEET: 1 NCRS Soils Ma 7 LEGEND -- —7915 — -- EXISTING V CONTOUR 4"SD 4'0 CPP DRAIN PIPE (>"STI 6"0 CPP DRAIN PIPE SCF SEDIMENT CONTROL FENCE i SWAI.E/RONllNE OF SURFACE FLOW (FLOWnDN AT = M MINIMUM) GRAPHIC SCALE f M PPFe 1 INSTALL SWALE ALONG THE BOUNDARY, DIRECT TO DRYWELLS 1-77 - \ -lam - _"ws- J r •�_StT�,A,c�C_�, �.. --_III% ( Landscafills"ped fill= 1 Landscaped i MT. 4 I Y III Z Q I II J � wTp I pq / ,.• 4"S J46ndscaped DIRECTION OFJ ' FLOW • r' r " NOTE•INSTALL 8;0 YARD GRADE THE SURF.AT,`Fi TO DIRECT FLOW WAY, DRAIN CONNECTED' TO BMSD bR 870 FROMTHE-BUILDING AND TO THE DRYWELLS ,bRAINtIPIPE )UNDER, • WALKWAY { • I a I n n�cf 11 oT'. t T'Ertry ')' ao:Walkpervious) 6"SD 6 PROPERT Neale Street ��yy�� GYI$TNb P�NBWY Landscrped 71K BUILDING AN. FLOW TO THI Driveway (Impervious) ' Q.1' Landsrnp0d�rl I 6••o.r 6••S))]� INSTALL TWO DRYWELLS � WITH SEDIMENT CONTROL LOGS AROUND THE INLETS UNTIL REVEGETATION HAS BEEN COMPLETED MJ752005 00762005 DRYWELLS T CONTROL I THE INLETS TATION HAS - _ NO.ffS 1. LANDSCAPING BY OTHERS. - - - 2. ENGINEER IS NOT RESPONSIBLE FOR DAMAGE OR FAILURE OF STRUCTURES WHERE SETBACKS ARE NOT FULLY MAINTAINED. A STRUCTURAL ENGINEER SHOULD DESIGN RETAINING WALLS AND ALL STRUCTURES TO MITIGATE THE AFFECTS OF SETTLEMENT AROUND THE DRYWELLS. 3. INSTALL ROOF GUTTERS AND 4' AND 6' CORRUGATED POLYETHYLENE STORM DRAIN PIPE TO DRYWELLS 4. STORM DRAIN PIPES TO BE INSTALLED KITH 0.5X MINIMUM ID SLOPE TOWARDS THE l HEAT TAPE d SHALL IN ALL INSTALLED IN ALL GUTTERS, DOWNSPOUTS, GUTTERS, D - - - - - - - _ R ROOF DRAIN PIPES AND STORM DRAIN PIPES. _ 5. FOUNDATION DRAINS ARE NOT TO BE CONNECTED TO THE o PROPOSED DRYWELLS o y d o P� m CD' INSTALL TEMPORARY SEDIMENT CONTROL FENCING ALONG THE EXISTING SIDEWALK, ASPHALT AND DOWNHILL PROPERTY LINES UNTIL REVEGETATION HAS BEEN COMPLETED NOTE: ALL FOUNDATION AND RETAINING WALLS LOCATED WITHIN 20' OF THE DRYWELLS SHALL BE PROPERLY DESIGNED, BY OTHERS, TO ACCOMMODATE SETTLEMENT WHICH MAY BE INDUCED BY THE DRYWELLS. ��--INSTALL SEDIMENT CONTROL LOGS AROUND THE EXISTING INLET UNTIL REVEGETATION HAS BEEN COMPLETED 0 L. P.iO1B �G1 Z III 111 2 00752005 TIGHTLY ABUTTING WITH NO GAPS (TYP.) TYPICAL GRASSED AREA APPROX. 900 12" MIN. TOPSOIL .TO EACH OTHER. - GRADE OVERFLOW SWALE - TO DRAIN AWAY FROM ALL STRUCTURES OR INSTALL 8"0 CPR OVERFLOW PIPE TO DAYLIGHT FRAME & GRATE, TRAFFIC IF WITHIN DRIVING AREAS I~ 24 [V �GRADE RINGS OF 24" —� EQUAL HEIGHT \ CONE SECTION OR FLAT LID 3" ROOF OR STORM DRAIN PIPC I THE LOCATION OF KNOWN UNDERGROUND UTILITIES HAVE SEEN PLOTTED BASED ON UTILITY MAPS, CONSTRUCTION/DESIGN PLANS, OTHER INFORMATION PROVIDED BY UTILITY COMPANIES. AND ACTUAL FIELD LOCATIONS IN SOME INSTANCES. THESE UTILITIES, AS SHOWN. MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND TO VERIFY LOCATION AND DEPTH BEFORE WORK BEGINS. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITIES DURING CONSTRUCTION. 2. ALL EXCAVATION FOR RETAINING WALLS, UTILITY TRENCHES, ROADWAYS. BUILDING STRUCTURES & DRAINAGE SHALL MEET OSHA REQUIREMENTS. 3. ALL CONSTRUCTION TO BE IN CONFORMANCE WITH THE LOCAL GOVERNING ENTITY'S RULES AND REGULATIONS 4. 95% STANDARD PROCTOR IS REQUIRED FOR ALL ROADWAY, DRIVEWAY, SLABS ON GRADE SUBGRADE CONSTRUCTION AND TRENCH BACKFILL UNDER THE SAME, UNLESS NOTED OTHERWISE. 5. ALL UTILITIES. BOTH UNDERGROUND OR OVERHEAD, SHALL BE MAINTAINED IN CONTINUOUS SERVICE THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR DAMAGES TO, OR INTERRUPTION OF. SERVICES CAUSED BY THE CONSTRUCTION. 6. THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION OPERATIONS TO THE AREA WITHIN THE STREET RIGHT-OF-WAY AND THE PROPERTY BOUNDARY. THE CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR CONSENT OF THE PROPERTY OWNER INVOLVED. ANY DAMAGE TO PRIVATE PROPERTY BY THE CONTRACTOR OUTSIDE THESE LIMITS WITHOUT THE PERMISSION OF THE PRIVATE PROPERTY OWNER WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 7. GRADE ALL DRAINAGE AWAY FROM BUILDING STRUCTURES IN ALL DIRECTIONS. DO NOT ALLOW WATER TO POND ON SITE. FOLLOW THE ADDITIONAL SURFACE AND SUBSURFACE DRAINAGE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER. 8, THE CONTRACTOR SHALL AT ALL TIMES KEEP TWO FULL SETS OF CONTRACT DRAWINGS MARKED UP TO INDICATE ALL AS -BUILT CONDITIONS. THE DRAWINGS SHALL BE PROVIDED TO THE OWNER UPON COMPLETION OF THE WORK. WHERE PRACTICAL, THE CONTRACTOR IS TO PROVIDE AT LEAST TWO TIES FROM PHYSICAL MONUMENTS TO SUBSURFACE STRUCTURES. 9. SITE TOPOGRAPHY AND BASE PLAN INFORMATION PROVIDED BY THE ARCHITECT. BUILDING FINISH FLOOR ELEVATIONS, ACCESS DRIVE GRADES AND LANDSCAPE GRADING TO BE DESIGNED BY OTHERS. SEE ARCHITECTURAL AND STRUCTURAL ENGINEERING PLANS. FOR ADDITIONAL BUILDING AND LANDSCAPE INFORMATION. 10. ALL PRODUCT INFORMATION SHOWN IS AS PROVIDED BY THE MANUFACTURER. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND COMPLYING WITH THE MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS FOR THE INSTALLATION OF ALL MATERIALS WITH SPECIAL ATTENTION TO PROPER SEALING OF MATING SURFACES. THE CONTRACTOR SHALL IMMEDIATELY CONTACT THE ENGINEER IF ANY DISCREPANCIES ARE FOUND BETWEEN THE DELIVERED PRODUCTS AND THOSE SHOWN ON THIS PLAN. 11. STORM DRAIN PIPES TO BE INSTALLED WITH 0.5% MINIMUM SLOPE TOWARDS THE DRYWELL SYSTEMS. HEAT TAPE SHALL BE INSTALLED IN ALL ROOF DRAIN PIPES, DOWNSPOUTS, TRENCH DRAINS, AND STORM DRAIN PIPES. STANDARD RISER J !' SECTION(S) WITH PLACE FILTER FABRIC OVER CRUSHED NATIVE BACKFILL IN 6 - STONE UPPER 6' 3 0 IO PERFORATED RISER - �_ O LL m% I POST (2" X 2^ NOMINAL) SECTION(S) WITH UQ" 24^ CRUSHED STONE IN o SILT FABRIC MIN. LOWER 6' OF DRYWELL NOTES STAPLED TO--,,. POSTS2F 1' 1. PRECAST MANHOLE SECTIONS TO MEET ASTM C-478. MIN. 2. BACKFILL EXCAVATION AROUND STRUCTURE WITH COMPACTED MIN. 1yf' CRUSHED STONE IN LOWER 6- (TOP OF PERFORATED '\ SECTIONS) AND WITH NATIVE MATERIAL TO lE" BELOW COMPACTED 42" R FINISH GRADE. PLACE 12" TOPSOIL AND RENEGE TATE BACKFILL MIN. 12 WITH NATIVE GRASSES. SILT FENCE — —� 3. OVERALL DEPTH, MINIMUM OF 10-FEET PER CITY OF ASPEN. FABRIC �1I IN. ANCHORED q 4. PERFORATED SECTION TO BE INSTALLED 4 FT. MINIMUM INTO IN TRENCH i ;_;. TYPICAL DRYWELL SECTION L ED E14GINEER TO BE ASTENCOUNTERED DETAIL AND ATTACHED GW IF GROUNDWATER OR BEDROCKLUVIUM. IMMEDIATELY ELYRVIOUS FRMLY TO SIRENC6H^ ANCHORED IN TRENCH AND FIRMLY ATTACHED SILT FENCE FABRIC TO POST ��6- x 6" TRENCH FLOW (N.T.S.) 5. DRYWELL GRATES SHOULD BE CLEANED AFTER EACH STORM EVENT AND SEDIMENT AND DEBRIS SHOULD BE REMOVED FROM DRYWELLS EVERY 12 MONTHS MINIMUM. SEDIMENT CONTROL FENCE DETAIL (N.T.S.) 9 ZONE AE ROs1R1NO F6 a � MY OF ASPEN"' Geo�aa ZONE X J lI E E\ STUDY ING OR APPROXIMATE SCALE IN FEET 500 0 501 0 NATIONAL FLOOD INSURANCE PROGRAM /� z ONE X�\ FIRM \ \ \ FLOOD INSURANCE RATE MAP \\ PITKIN COUNTY, I o �I COLORADO AND 7875 \ C�Ty,F. I INCORPORATED AREAS '878 c, r Oft, C / kFdararfeya v 6,�, oe PANEL 204 OF 325 ZO � ZONE 7898 `F&T 7905 r 13 cU\Feemritl9? j X7917 ✓� �P.O LEFFE JUN E4, 1987 Federal Emergency Management Agency This is an official copy or a no mn of the atm@ r0orenced 11000 mapIt was extracted using F-MR On -Line. This map does net reflect changes \g2 or ementlmen a which may dhave been made subsequent to the date on the A E Htle dock. For the latest product In ormatlon about National Flood Inauranee E Program flood maps check the FEMA Flood Map Store at w .msafema. gov 0 r— L =>CD O O rQ N C) CD O O k7l %il 00752005 00762007 Appendix • • 00752005 no762005 114 Neale Street, Aspen DRAINAGE CALCULATIONS 12.2005 Historic Conditions Area (Total): 15,160 sf = 0.348 ac. f Concentration. Tc FEW Velocity Method L = L L = 1601 Tc = V k*sgrt(S) S = 11.2 % k = 0.25 *(Forest) Tc = 191 sec. = 3.19 min. use: 9.00 min. (ITF) C = 0.20 (Forest, cottonwood, brush, ,grasses, Soil Type B, 6%+, Good Condi 5-yr = 100-yr = IDiseharlZe, q: q=CIA 3.9 in/hr (ITF) 6.5 in/hr (ITF) q5 = 0.271 cfs gloo = 0.452 efs Hydrologic Analysis and Design, R. McCuen, Prentice Hall, 1959. 00752005 00762005 114 Neale Street, Aspen DRAINAGE CALCULATIONS April 12, 2005 BUI Project: Brien Proposed Conditions Area (Total): 15,160 sf = 0.348 ac. Impervious: 7,145 sf = 0.164 ac. rass/Landscaped: 8,015 sf = 0.184 ac. Time of Concentration, Tc: Velocity Method* L, + LZ L, = N/A L2 = N/A ' Tc = kj*sgrt(Sj) k2*sgrt(S2) S, = N/A % S2 = N/A % k, = N/A k2 = N/A Tc = N/A sec. = Fast min. use: 9.00 min. (171717) Runoff Coefficient, C: C, = 0.95 rt(Impervious) C2 = 0.30 *(Grass/Landscaped, 6%+) Weighed C = 0.61 Rainfall Intensity, I: 5-yr = 3.9 in/hr (ITF) 100-yr = 6.5 in/hr (TTF) Discharge, q: q = CIA q$ = 0.823 cfs gioo= 1.372 efs Hydrologic Analysis and Design, R. McCien, Prentice Hall, 1989. 00752005 n076200r 114 Neale Street, Aspen DRAINAGE CALCULATIONS April 12, 2005 BUI Project: Brien Input into AutoCAD Hydrology TR-55 Tabular Method By: DJW Date: 4/1212005 Area: Property: 15,160 SF± Precipitation, 24 hr: 100-yr: 2.8" Time of Concentration, Tc Historic: Sheet=160'@11.2°i Shallow,= N/A Tc= 0.642 hr Proposed: Sheet= Fast Shallow,= Fast Tc= 0.100 hr (min.) Soil Type: Type Ci: 92: Redrob Loam (deep, poorly drained, moderate permeability) Curve Number, CN Property: Historic=44 Cottonwood, brush, grasses, 80%vegetative Cover Dev.=92 52% Grass.Landscape (86), 48% Impervisous (98) Historic Runoff, Q Property: QE,A too= 0.001 cf Developed Runoff, QF Property: QD,A 100= 1.084 cf Detention Required, VG Property: VS,A= 1379 cf 00752005 0076200 D 114 Neale Street, Aspen DRAINAGE CALCULATIONS April 12, 2005 BUI Project: Brien Detention Calculations Rational Formula Hydrograph Method: Vs, = 0.08264 * (gP-gH) * tH qP,S = 0.823 cfs gP,100 = 1.372 cfs 911,5 = 0.271 cfs gH,100 = 0.452 cfs tH = 0.15 hr q,cfs 5-Year VST.S = 0.00682 ac-ft qP ----- = 297 cf qH 100-Year: ' VST,100 = 0.01136 ac-ft = 495 of Imperical Method: tP tH t, hr Vs kA k = (1.78i-0.002i2-3.56)/1000 i = 47.1 % k = 0.0758899 V5= 1,150 c.f. FAA Method: Q=CI90A 90= 1.5 in/hr A= 0.348 ac. QH90,100= 0.104 QP90,100= 0.317 VS=(CP90,100-CH90,100)*90 min*60sec/min. VS= 1,146 c.f. SCS-TR55 Method VS 1,379 c.f. *AutoCad Hydrology SCS-TR55 Tabular (See Attatched Calculations) Average: Vs= 1,042 c.f. 114 Neale Street, Aspen DRAINAGE CALCULATIONS April 12, 2005 BUI Project: Brien 6'0 Drywell Calculations Calculation of Drywell and Gravel for Each Drvwell (Four-6'0 Drywells Variables Volume to Width of Depth of gravel Dia of Percent Detain (cf) Gravel (ft) Below M.H. (ft) M.H. (ft) Voids (%) 261 1 1 6 40 Area of M.H.(sgft) 28.3 Area of Gravel (sqft) 22.0 Depth Volume of Vol of Gravel Vol of Drywall Vol of Drywell Vol of Total Volume Varied Gravel Voids Conic Section Cyl. Section Drywall Volume Met (ft) (cf) (cf) (cf) (c (cf) (cf) 1 0.0 0.0 62.8 0.0 62.8 62.8 no 2 0.0 0.0 62.8 0.0 62.8 62.8 no 3 0.0 0.0 62.8 0.0 62.8 62.8 no 4 0.0 0.0 62.8 28.3 91.1 91.1 no 5 0.0 0.0 62.8 56.5 119.4 119.4 no 6 0.0 0.0 62.8 84.8 147.7 147.7 no 7 50.3 20.1 62.8 113.1 175.9 196.0 no 8 72.3 28.9 62.8 141.4 204.2 233.1 no 9 94.2 37.7 62.8 169.6 232.5 270.2 Meets Min. 10 116.2 46.5 62.8 1 197.9 260.8 307.2 1 Meets Min. Note: Gravel depth begins 6.0' below surface (freeze depth), drywell shall beat least 10' deep per City of Aspen. herefore Four 4 6' dia, manholes with 1' of gravel at a minimum depth of 10' will exceed on -site detention re uirements u • O O O O --j -j 011 V7 N N O O O O v-T vt 00752005 Brien Property 114 Neale St. 100-yr Runoff Existing Conditions 4/12/05 TR-55 Tabular Hydrograph Method Input Summary Description ..................... 100-yr Historic Conditions Rainfall Distribution ........... Type II Ia/P Interpolation .............. on Total Area ...................... 15160.00 ft2 Peak Time ....................... 12.700 hrs Peak Flow ....................... 0.001 cfs Given Input Data: ------------------------------------------------------------- subarea Area CN Tc Tt Rainfall Description (ft2) (hrs) (hrs) (in) ------------------------------------------------------------- Site 15160 44 0.642 0.000 2.80 Support Data: subarea Name: Site, Row: 1 sheet Flow ---Description ..................... Manning's n ..................... 0.800 Flow Length ..................... 160.00 ft Two Yr, 24 hr Rainfall .......... 1.60 in Land slope ...................... 0.11 ft/ft computed Sheet flow time ................> 0.642 hrs Total Time of Concentration ................> 0.642 hrs 00762005 u 00752005 Brien Property 114 Neale St. Proposed Conditions 4/12/05 TR-55 Tabular Hydrograph Method Input Summary Description ..................... 100-yr Proposed Conditions Rainfall Distribution ........... Type II Ia/P Interpolation .............. On Total Area ...................... 15160.00 ft2 Peak Time ....................... 12.100 hrs Peak Flow ....................... 1.084 cfs Given Input Data: ------------------------------------------------------------- Subarea Area CN Tc Tt Rainfall Description (ft2) (hrs) (hrs) (in) ------------------------------------------------------------- site 15160 92 0.100 0.000 2.80 Support Data: Subarea Name: Site, Row: 1 Sheet Flow ---Description ..................... Manning's n ..................... 0.011 Flow Length ..................... 20.00 ft Two Yr, 24 hr Rainfall .......... 1.60 in Land slope 0:45 ft/ft Computed Sheet flow time ........ > 0.002 hrs Shallow concentrated Flow ------------------------- Description ..................... Surface......................... unpaved Flow Length ..................... 100.00 ft watercourse slope ............... 0.13 ft/ft velocity ........................ 5.82 fps Computed shallow flow time .....................>0.005 hrs Total Time of Concentration .........................> 0.007 hrs 00762005 Brien Property 114 Neale St. 100-yr Detention 4/12/05 Basin Output Pond Name ....................... Distribution Type ............... Frequency Type .................. Area .. Peak Inflow ..................... Peak outflow .................... Runoff.......................... Runoff volume ................... storage volume .................. • 00752005 00762005 Type II 100 years 15160.00 ft2 1.084 cfs 0.001 cfs 1.970 in 2488.611 ft3 1378.624 ft3 CTUTHOMPSON, INC. CONSULTING ENGINEERS WA L % % SOILS AND FOUNDATION INVESTIGATION TRETTIN RESIDENCE 114 NEALE STREET ASPEN, COLORADO Prepared For: MR. HENRY TRETTIN 3350 Ocean Park Blvd. Santa Monica, CA 90405 Job No. GS-3808- December 2, 2002 CTL/THOMPSON, INC. CONSULTING ENGINEERS 234 CENTER DRIVE • GLENWOOD SPRINGS, COLORADO 81601 0 (970) 945-2809 0 0A2005 TABLE OF CONTENTS SCOPE SUMMARY OF CONCLUSIONS SITE CONDITIONS PROPOSED CONSTRUCTION SUBSURFACE CONDITIONS SITE EARTHWORK FOUNDATION SLAB -ON -GRADE CONSTRUCTION BELOW -GRADE CONSTRUCTION SUBSURFACE DRAINAGE SURFACE DRAINAGE LIMITATIONS FIGURE 1 - APPROXIMATE LOCATIONS OF EXPLORATORY PITS FIGURE 2 - SUMMARY LOGS OF EXPLORATORY PITS FIGURES 3 AND 4 - GRADATION TEST RESULTS FIGURE 5 - EXTERIOR FOUNDATION WALL DRAIN ml 1 1 2 2 3 3 4 6 6 7 8 8 MR. HENRY TRETTIN 114 NEALE STREET CTL/T JOB NO. GS-3808 0 6191917g This report presents the results of our soils and foundation investigation for the proposed Trettin Residence at 114 Neale Avenue in Aspen, Colorado. We conducted the investigation to evaluate subsurface conditions at the site and provide foundation recommendations for the proposed construction. Our report was prepared from data developed during our field exploration, laboratory testing, engineering analysis and our experience with similar conditions. This report includes a description of the subsurface conditions found in our exploratory pits, and presents our opinions and recommendations for design criteria for recommended foundations and floor systems, and geotechnical and construction criteria for details influenced by the subsoils. The recommendations contained in this report were developed based on the currently planned construction. If plans will differ significantly from the descriptions contained herein, we should be informed so that we can check that our recommendations and design criteria are appropriate. A summary of our conclusions is presented below. SUMMARY OF CONCLUSIONS 1. Subsoils encountered in our exploratory pits consisted of 2 to 3 feet of sandy to silty clay "topsoil' underlain by clayey to silty gravel with cobbles and boulders to the total explored depth of 15 feet. Free ground water was not found in our exploratory pits at the time of excavation. Pits were backfilled immediately after excavation operations were completed. 2. We recommend constructing the residence on footing foundations supported by the undisturbed, gravel soil. Design and construction criteria for footings are presented in the report. 3. Wejudge potential differential movementof slabs -on -grade supported by the native gravel at this site will be low. Performance of slab -on - grade basement and garage floors will likely be good. MR. HENRY TRETTIN 114 NEALE STREET 1 CTL/T JOB NO. GS-3808 4. Surface drainage should be designed to provide for rapid removal of surface water away from the proposed residence. SITE CONDITIONS The Trettin Residence is proposed at 114 Neale Street in Aspen, Colorado. The lot is an approximately 0.35 acre parcel located northeast of the intersection of Neale Street and Queen Street in Aspen, Colorado as shown on Figure 1. Single- family residences are located on property to the north and east of the subject lot. It appears that soils were excavated from the area of the building envelope in the past. Building envelope ground surface is comparatively flat and lower than surrounding grades. Ground surface in the northeast part of the lot slopes gently down to the southwest, to the crest of a steep slope that drops approximately 10 feet down to the building envelope. Approximately 4 to 5 feet high steps in ground surface elevation are south and east of the building envelope. Irrigated grass is present on much of the property with numerous trees and shrubs PROPOSED CONSTRUCTION We understand the proposed Trettin Residence will be a three -level, wood - frame building with the firstfloor level constructed as a walkout basement. A garage will be incorporated in the first floor level. Basement and garage floors will likely be slabs -on -grade. We were informed that foundation walls may be constructed with a precast, concrete panel system, such as "Superior Walls". Foundation loads are expected to vary between 1,010 and 3,000 pounds per lineal foot of foundation wall with maximum interior column loads of 30 kips. Maximum foundation excavation depths on the order of 8 to 10 feet deep are expected. If construction will differ significantly from the descriptions above, we should be informed so that we can adjust our recommendations and design criteria, if necessary. MR. HENRY TRETTIN 114 NEALE STREET Z CTLT JOB NO. GS-3808 SUBSURFACE CONDITIONS Subsurface conditions at the site were investigated by excavating three exploratorypits (TP-1 through TP-3) at the approximate locations shown on Figure 1. Excavation operations were directed by our representative who logged the soils encountered in the pits and obtained samples. Samples obtained in the field were returned to our laboratory where field classifications were checked and typical samples selected for testing. Graphic logs of the soils encountered in our exploratory pits are shown on Figure 2. Subsoils encountered in our exploratory pits consisted of about 2 to 3 feet of sandy to silty clay "topsoil" underlain by clayey to silty gravel with cobbles and boulders to the total explored depth of 15 feet. Observations during excavation indicated the gravel was dense to very dense. Free ground water was not found in our exploratory pits at the time of excavation. Pits were backfilled immediately after excavation operations were completed. Three samples of the gravel selected for gradation testing contained 50 to 63 percent gravel, 34 to 38 percent sand, and 3 percent silt and clay size material. Gradation test results are shown on Figures 3 and 4. SITE EARTHWORK We expect minimal site grading will be performed. Areas which will receive fill should be stripped of vegetation, organic soils and debris. The on -site soils free of organic matter, debris and rocks larger than 6 inches in diameter can be used as fill. Fill should be placed in thin, loose lifts of 10 inches thick or less, moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95percent ofstandard Proctor (ASTMD698)maxim urn dry density. Placement and compaction of fill should be observed and tested by a representative of our firm during construction. MR. HENRY TRETTIN 114 NEALE STREETS CTLT JOB NO. GS-3808 0 We anticipate excavations for the foundation and utilities can be accomplished using conventional, heavy-duty excavation equipment. Excavation sides will need to be sloped or braced to meet local, state and federal safety regulations. We believe the native gravel soil will classify as a Type C soil based on OSHA standards governing excavations. Temporary slopes deeper than 5 feet should be no steeper than 1.5 to 1 (horizontal to vertical) in Type C soils. Contractors should identify the soils encountered in the excavations and refer to OSHA standards to determine appropriate slopes. Free ground water was not encountered in our exploratory pits during excavation operations. We do not anticipate excavations forfoundations or utilities will penetrate ground water, however, excavations should be sloped to a gravity discharge or to a temporary sump where water can be removed by pumping. The ground surrounding the excavations should be sloped to direct runoff away from the excavation. FOUNDATION Foundation recommendations are developed based on subsurface conditions exposed in exploratory borings or pits, laboratory test results, engineering analysis and experience. We understand a precast, concrete panel foundation wall system, such as a "Superior Wall" system is being considered for the Trettin Residence. Some of these precast wall systems are designed as essentially walls -on -grade placed on a layer of washed rock. We do not have experience regarding long-term performance of these systems with the subsoil and subsurface water conditions which are present in the local area. We recommend cast -in -place foundation walls or precastwall panels be placed on footing foundations which are supported by the undisturbed, native gravel soil. If a precast panel system is used, care should be taken to seal joints between panels to prevent infiltration of subsurface water into below -grade areas of the residence. MR. HENRY TRETTIN 114 NEALE STREET CTLIT JOB NO. GS-3808 4 0 The completed foundation excavation should be inspected by a representative of our firm prior to placing forms to confirm that the gravel is exposed and suitable for support of the footings as designed. We anticipate maximum total settlements of less than 1 inch with differential settlement of about 1/2 total settlement. Recommended design and construction criteria for footings are presented below. 1. The footing foundations should be supported on the undisturbed, native gravel soil. Soils loosened during the excavation or forming process for the footings should be removed or the soils can be re - compacted prior to placing concrete. A leveling course consisting of a 4-inch thick layer of densely compacted, CDOT Class 6 aggregate base course can be used, if necessary. 2. Footings should be designed fora maximum soil bearing pressure of 5,000 psf. 3. Continuous wall footings should have a minimum width of at least 16 inches. Foundations for isolated columns should have minimum dimensions of 24 inches by 24 inches. Larger sizes may be required, depending upon foundation loads. 4. Grade beams and foundation walls should be well reinforced, top and bottom, to span undisclosed loose or soft soil pockets. We recommend reinforcement sufficientto span an unsupported distance of at least 10 feet. Reinforcement should be designed by a qualified structural engineer considering the effects of lateral loads on wall performance. 5. The soils under exterior footings should be protected from freezing. We recommend the bottom of footings be constructed at a depth of at least 42 inches below finished grades for frost protection. The City of Aspen building department should be consulted to verify the required depth. MR. HENRY TRETTIN 114 NEALE STREET 5 CTUT JOB NO. GS-8808 • SLAB -ON -GRADE CONSTRUCTION Basement and garage floors will likely be slabs -on -grade. Based on our laboratory test data and our experience, we judge slab -on -grade construction can be supported by the undisturbed, gravel soil or structural fill built with the native gravel with low potential risk of differential movement and associated damage. If required, a leveling course consisting of a 4-inch thick layer of densely compacted, CDOT Class 6 aggregate base course can be used. Slabs should be separated from exteriorwalls and interior bearing members with slip joints which allow free vertical movement of the slabs. Exterior patio and porch slabs should be isolated from the residence. These slabs should be well - reinforced to function as independent units. Frequent control joints should be provided according to American Concrete Institute (ACI) recommendations to reduce problems associated with shrinkage and curling. BELOW -GRADE CONSTRUCTION Foundation walls which extend below -grade should be designed for lateral earth pressures where backfill is not present to about the same extent on both sides of the wall. Many factors affect the values of the design lateral earth pressure. These factors include, but are not limited to, the type, compaction, slope and drainage of the backfill, and the rigidity of the wall against rotation and deflection. For a very rigid wall where negligible or very little deflection will occur, an "at -rest' lateral earth pressure should be used in design. For walls which can deflect or rotate 0.5 to 1 percent of wall height (depending upon the backfill types), lower "active" lateral earth pressures are appropriate. Our experience indicates typical below -grade walls in residences can deflect or rotate slightly under normal design loads, and that this deflection results in satisfactory wall performance. Thus, the MR. HENRY TRETTIN 114 NEALE STREET 6 CTLT JOB NO. GS-3808 0 earth pressures on the walls will likely be between the "active" and "at -rest' conditions. If the on -site soils are used as backfill, we recommend design of below -grade walls using an equivalent fluid density of at least 45 pcf for this site. This equivalent density does not include allowances for sloping backfill, surcharges or hydrostatic pressures. The recommended equivalent density assumes deflection; some minor cracking of walls may occur. If very little wall deflection is desired, a higher equivalent fluid density may be appropriate for design. The structural engineer should also consider site specific grade restrictions on the behavior of the walls. Backfill placed adjacent to foundation wall exteriors should be free of organic matter, debris and rocks larger than 6 inches in diameter. Backfill should be moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of standard Proctor (ASTM D 698) maximum dry density. 011 f�13ITIN:461 7e1VrM Water from rain, snow melt and surface irrigation of lawns and landscaping frequently flows through relatively permeable backfill placed adjacentto a residence and collects on the surface of relatively impermeable soils occurring at the bottom of the excavation. This can cause wet or moist conditions in below grade areas after construction. To reduce the likelihood water pressure will develop outside foundation walls and reduce risk of accumulation of water in the firstfloor level, we recommend provision of a foundation drain. The drain should consist of a 4-inch diameter, open joint or slotted pipe encased in free draining gravel. The drain should lead to a positive gravity outfall, or to a sump pit where water can be removed by pumping. A typical foundation drain detail is presented on Figure 5. In addition, crawl spaces (if constructed) should be provided with adequate ventilation. MR. HENRY TRETTIN 114 NEALE STREET 7 CTLIT JOB NO. GS-3808 A recent practice is to circulate conditioned air from living areas through the crawl space. The mechanical systems contractor could evaluate the appropriateness of this type of system. SURFACE DRAINAGE Surface drainage is critical to the performance of foundations, floor slabs and concrete flatwork. The ground surface surrounding the exterior of the residence should be sloped to drain away from the residence in all directions. We recommend providing a slope of at least 12 inches in the first 10 feet around the residence, where possible. In no case should the slope be less than 6 inches in the first 5 feet. Backfill around the exterior of foundation walls should placed be in maximum 10 inch thick loose lifts, moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of standard Proctor (ASTM D 698) maximum dry density. The residence should be provided with gutters and down spouts. Roof downspouts and drains should discharge well beyond the limits of all backfill. Splash blocks and downspout extensions should be provided at all discharge points. LIMITATIONS Our exploratory pits were located to obtain a reasonably accurate picture of subsurface conditions. Variations in the subsurface conditions not indicated by our pits will occur. We should observe the completed foundation excavation to confirm the native gravel soil is exposed and suitable for support of the footings as designed. Our report was based on conditions disclosed by our exploratory pits, laboratory testing, engineering analysis and our experience. Criteria presented MR. HENRY TRETTIN 114 NEALE STREET CTUT JOB NO. GS-3808 reflect our understanding of the proposed construction. If construction will differ significantly from the descriptions in the report we should be informed so that we can check that our recommendations and design criteria are appropriate. This investigation was conducted in a manner consistent with that level of care and skill ordinarily exercised by geotechnical engineers currently practicing under similar conditions in the locality of this project. No other warranty, express or implied, is made. If we can be of further service in discussing the contents of this report or in the analysis of the influence of the subsoil conditions on the design of the structure, please call. CTUTHOMPSON, INC. 4Ja s D. Kell St Geotec al Engineer Reviewed Ai John John �echlii Bran Man; JDK:JM:cd (5 copies sei MR. HENRY TRETTIN 144 NEALE STREET CTLIT JOB NO. GS-3808 9 TRETTIN RESIDENCE 114 NEALE STREET ASPEN, COLORADO APPROXIMATE LOCATIONS OF EXPLORATORY PITS Job No. GS-3808 Fl9' I TP-1 TP-2 TP-3 0 Fa Fa va 0 5 0 o 5 a� L_ dLi m 10 O 0 e� 0 0 0 e� 0 10 S E m e� 0 15 15 20 20 LEGEND: ® Sandy to silty clay "topsoil" roots and organics, moist, dark brown. Gravels, cobbles, boulders, o��, dense to very dense, slightly moist to moist, tan, brown. (GP) Indicates bulk sample. NOTES: 1. Exploratory pits were excavated with a trackhoe on November 15, 2002. Pits were backfilied immediately after excavation operations were completed. 2. No free ground water was found In our exploratory pits at the time of excavation. 3. Locations of exploratory pits are approximate. 4. These exploratory pits are subject to the explanations, limitations and conclusions as contained in this report. SUMMARY LOGS OF EXPLORATORY PITS Job No. GS-3808 Fig. 2 0 I HYDROMETER ANALYSIS I SIEVE ANALYSIS 25 HR. 7 MR. TIME READINGS U.S. STANDARD SERIES CLEAR SQUARE OPENINGS 45 MIN. 15 MIN. 60 MIN. 19 MIN. 4 MIN. I MIN. '200 '100 '50 '40 '30 '16 *10 'S -4 31W 314' IW 3' 5*6' 8* 100 ---------- ---- — ---------- -------- ----- ---- a ---------- - ::: ---- ------ : - ----- -- -------- - ------ - - ----- -- -------- ------- ------- ------ --- ----------- ------------ ----- ----- ---------------- ------------- ------ --- --- F ----- 10 80 ------- --- ----------- ---------- ----- --- --- ---------- --------- ------ --------------- -------------- - -------- ----- ------- ---- ----- ---------- - ---- ---- - ------ ------- -------------- — ------ ----------- -------- --- --------------- --------------- ----- ----- 20 70 ---------- :--: -- ------ -- ----- ------ ------------------------ ------------------ ------- ------- -- ---------- -- ----- -------- --- 4- 30 60 ------- ------- ---------- ---------- ------ ------ ------- ------ - ------- ------- --------- -------- ------- -------- ------- ------- ---- ---- ---- ------- ------- ---------- ------ -------- ------- ---------------- ----- ;:::: ---- ---- 40 ------- --------------- - ----- ::: — ::: -- :::::::: ------- :- ----- - - ------- -- oo,-::: ------- -- ----- ------- -- soso ------- ---------- ------ -------- ------- * ------ ------ - ------- - ------- ------- -------- - - -------- ------ --- -- ------ - -------- ------- ------- -------- ---------------- - ------- ------ ---- --- ---- --- ------ �4r ---- ------- -------- ----- 40 ---------------- ------- ---- --- --'40 ------- ------- ---- ------- -------- ----- LO -------- ------- ---- --- ----- 30 ------- --- ----- ------ -- - ------- -- ---- -------- ------- ----- 1- ------ I ---------- ---------- ------ ----- - ------- ------------ ::-: ::-:W:- ------ ---- 70 20 ----------- --- ------ --------------- ------- ----- ------- --- - ----- ----- ---------- so 10 ------- ----- ---- ------- -- ---------- ------- - ----------- -------- - 0 - --- -- ---- -- ------- .001 0.002 005 .009 .019 M? .074 .149 .297 .690 1.19 2.0 2.38 4.76 9.52 19.1 36.1 76.2 127 200 0.42 152 DIAMETER OF PARTICLE IN MILLIMETERS I CLAY (PLASTIC) TO SILT(NON-PLASTIC) SANDS GRAVEL FINE MEDIUM I COARSE FINE COARSE I Sample Of GRAVEL, CLEAN (GP) GRAVEL 63 % SAND 34% From TP-1 AT 9-10 FEET SILT & CLAY3 % LIQUID LIMIT - % PLASTICITY INDEX - % I HYDROMETER ANALYSIS I SIEVE ANALYSIS 25 HR. 7 HR. TIME READINGS U.S. STANDARD SERIES CLEAR SQUARE OPENINGS 45 MIN. IS MIN. 60MIN. 19MN. 4MIN. 1MIN. 200 -100 '40 20 -16 -10 T -4 3/81, 14" IW 3" 5"6 a, 100 4 4 -1 t ------- ------- 0 - --- -- ----- - ------______ --- - - ----------- ------- ------- ---- -- -------- ------- --- 10 so ------- --- -- - ------ ---- I -------- ---- ---- ------ ------ ------- ----- - --- -- --------- ------ -------- ------- ----- ------- ------------ ---------------- ------------ -- ' ----- - -------- ------ ........ 20 70 -------- ---------- ----------------- ------ ------- ------------ ------------ - -- — ----- — — --------- ----------- - ---------- ----- ----- - -- - / ----- ------ - ------ ----------- -; ----- ------- ----- i - ----- — ------ 30 -------- ---------- ------ - - ------ --------- ------- -------- - ------ ------ w --- ------ -------- ------- - www-ww,- W--Ww-w ------- ---------- ___ --- --- - ------ --- - - : -- -------- -- - ------- --- ------------ ----- - -------- -- --- - 40 50 - - ------- ---------- -------- ------ - ---- --------- --- w ---- ---- WW - ------- ------- --------------- -------- -------- --- -- - ----- ----------- ---- ------------ ----- 00-, ------------------- --- 50 U 40 ----- 1 - ----- ----- -------- -- --- ---------------- ------- ----- ----- - -------- ----- 60 -- ----- ------ - -- ----- --------------- ----- ---------------- -- W— --- ------- --- --- --- ------------ --- ----- ----- -- ------ ------- ------- T- -------- ---------- ------ -------- --- -------- ------------ ----------- 1 20 ---- ---------- ------ -------- ----- --------- - ----- - ...... 1- -- ----------- - ---------------- ---- ------- --- w ---- -------- 80 -- ------------- --------- ------ ------- ...... ---- ------- ---------------- ---- - -------- ----- i- w --- ---- -------- ------- ----- - - - --- ------- 11 - ------- - ----------- ---- ---------- ---------- ---- ------ --- - - - w ----- W—W --- -------- -------- - :::::!: ------- - --- :1::::::: w --- w -- -- --- 100 .w1 O.M .009 .019 .037 074 .149 297 WO 1.19 2.0 2.38 4.76 9.52 19.1 36.1 76.2 127 200 0.42 152 DIAMETER OF PARTICLE IN MILLIMETERS SANDS GRAVEL I CLAY (PLASTIC) TO SILT (NON -PLASTIC) i FINE I MEDIUM COARSE I FINE I COARSE Sample Of GRAVEL, CLEAN (GP) GRAVEL 61 % SAND 36% From TP-2 AT 13-14 FEET SILT & CLAY 3 % LIQUID LIMIT - % PLASTICITY INDEX - % Gradation JOB No. GS-3808 Test Results FIG. 3 E 0 FM I HYDROMETER ANALYSIS I SIEVE ANALYSIS 25HR. 7HR. TIME READINGS U.S. STANDARD SERIES CLEAR SQUARE OPENINGS 45 MIN. 15 MIN. 60 MIN, 19 NUN. 4 MIN. I MN. 200 '100 % '40 '30 *16 -10-8 -4 3W 3/4" 1W' 3" 5"6' 8' 100 7 ----- ::,- :: ---- -------- I ------- ---- -- - ------- I. ------- ----- --- --- ------------- ----- - ----- 0 so ------ --- ---------- ----- ------ I:: I - ------- ----- ...... -- ------- ------- ------ 10 ---------- ------ -------- - - .............. ...... -- ----------- - -- - ----- 1 ---1 ------ ------- . ----- I - ............ -------- ------- --------------- ---- 11 ----- 20 70 ---- -------- - ------- .......... ............... ..... -------------- ----•- -------- ------- 30 60 ------- ------- ---------- ---------- ------ ------ -------- -------- ----- - ---------------- ------- ----- ----- ---------- --------- ------ ------ -------- ------- ze ---------- ------ - — --- ------- ---------------- ------- --- ----- ------- ----- ------- — ------- -------- -------- -- 40 50 ------- ---------- ------ --------- --------- -- ------ -------- ----- ------- . ------- ---- ----- --- --- --- ------- ------- ------- ------- ----- - ----- ----- ----- ----- ---------- - - -- - --- ----- --- ---------- ------ - --------- ----- ------------- ----- - -------- 4r- so ----- ---- ------- ------- ------- ----- -------- - t ---- ----- ------- -------- - ------- -------- -------- --- ---- - ------- ----- ---- ------ ---------------- -- ------ - --- -- - ------ ------- ------- ----------- --- ------------ 4- ----- — : -:': --- ------- ------- 60 30 --- --- -- - -- ------- ------- ---------------- ----- — ------------- ------------ -- ----- ----- ------ ----- ------ ......— ---- ----- - ----------- ------- ---------------- -------- --- ----- --- ---. ---:------ -- ----- ------- ------ 70 20 - ------- ---- -------------------------------- - ----------- -A-- ---------- ------ -------- ------- ------------------- --- ---------------------- I-- -------- -1-- ----- 1.----- ------------- ------ - 10 ----- ------------------ ----------------------- --I- ---------------- --- -- ---- - -- ------- ---- ----- -------------------- ---------------------------- ------ - -- -- -- I.... ... -- - ---- -----:------ - - --- ---- ------- ------:.----- - ------------------ 0 ---------------------- - D01 0.002 .005 .009 .019 .037 .074 .149 .297 690 1.19 2.0 2.38 4.76 9.52 19.1 36.1 76.2 127 TOO 0.4� 152 DIAMETER OF PARTICLE IN MILLIMETERS I CLAY (PLASTIC) TO SILT (NON -PLASTIC) I SANDS GRAVEL FINE I I COARSE I MEDIUM I FINE COARSE COBBLES Sample Of GRAVEL, CLEAN (GP) GRAVEL 59 % SAND 38 % From TP-3 AT 4-5 FEET SILT & CIDW-3 % LIQUID LIMIT - % PLASTICITY INDEX - % I HYDROMETER ANALYSIS SIEVE ANALYSIS ---1 25 HR. 7 HR. TIME READINGS U.S. STANDARD SERIES CLEAR SQUARE OPENINGS 45MIN. ISMIN. WMIN. 19MIN. 4MIN. IMN. 2m -100 '50 '40 nO -16 -10-8 -4 w 3/4" 1%* y YT r 100 ------- ------- ------ 90 - -------- --------------- -- - ----------- ------------- ---- i - ------ --------- ------- I ------ -------- ---------- ---------- ------ ------ ----- -- ------- ------- --------------- -------- ---- --- ---- ------- --- - ----------- ------- ------- -- -------- -------- ----- 10 80 I ------------- ---- - 1— ----- I - --- ---------- -------- --- --- --- --- ------- -------- 1. ---------- ---------- ------ ------ -------- --- ---- ------------ ------------ -- —= ----- i- .... --- — — -------- — -------- -------------- ------- --- 20 70 -------- ----- -- ----- ----- ------- ---- ------------ ------------ ---- ------- ---------- - --------- ------ ------- -- ---- 30 -------- -- -------- -------- ---------- w -------- - ------ ------ ........ - ------- - .4- - so- ------ ------- -------- -------- ----- ---- Z 40 rc ------------ -- ------- - 50 ------ - --------------- - ----- W-,.--Ww -- -------- ----- ------- -------- ---------- --------- ---------- - ------ --------- ------- --------- ----------- ---- ----- ------- - ------- ------- ---- --------------- ------- - 11 ---- --- -------- so 40 ------ -------- ------ ------------- --- ----- - ---------------- ----- - ------ -------- --- - ------- --- 4 ---- ----- :::::::: :-_:- - ---------------- -- -------- ------- -------- - ---- 4- w ---- ------- --- ----------- ---- --- - ------------- -- - ------- — ------ w ------- - - ----- ---------------- ----- -------- ---- __.__.. ------- ______. W-W ---- -------- 20 -- ------ -------- — .................. - --- ------------- ------ w ----- --- ----- - W-4- ---W--W --------- ---- :::: ------ --- — ... ww ------ ------- - - - - - - - - - - ---- - - ------ - - - - - -- 9---- --- :::: — - - - - - - - - 9 ------------------------ ---------------- ----- ------------------ ----- I -- ---- ---------- -W ----- -------- -------- ----- i- — 80 10 --------- ---------- ------ -- ------- — - : ....... ---------------- --W--W--W ------- --- --- ------- W — -1 ------------- ------- - - - ------------------- ---- - - - -------- 9 ----- ::: ::::: ::::-:: -: - 4w --- 9- .... ------ -------- -- - - - - - - w ----- ------- -------- w ------ I - w ----- ---- . . --- ------------ . . . . . . . --- I ---------------- ----- ww - ------- ---- ------- --- ------ - ------- ------- ----- --- go 0 - - - - - - - - - - ------- - - - - —:- I I - — ---------- ------- 11 --- --- ----- - - W-� ------- ----- ---- ----- IDO .001 0.002 ODS .019 .037 .074 .149 .297 0W42 590 1.19 20 2.38 4.76 9.52 19.1 361 76.2 127 2162 M DIAMETER OF PARTICLE IN MILUMETERS I CLAY (PLASTIC) TO SILT (NON.PLASTC) SANDS i GRAVEL FINE I MEDIUM COARSE I FINE I COARSE COBBLES Sample of From JOB NO. GS-3808 GRAVEL % SAND % SILT & CLAY % LIWIDLIMIT—% PLASTICITY INDEX % Gradation Test Results F1G.4 �'S'Ri� �D�� SLOPE PER REPORT BACKFILL (COMPOSMON MID COMPACTION PER REPORT) BELOW GRADE WALL SLOPE ENCASE PIPE IN WASHED PER CONCRETE AGGREGATE (ASTM OSHA C33, NO. 57 OR NO. 67) EXTEND GRAVEL TO AT LEAST 1/2 HEIGHT OF FOOTING. 7 COVER GRAVEL FILTER FABRIC. 8" MINIMUM OR BEYOND SLOPE FROM OF FOOTING. (WHICHEVER NOTE: DRAIN SHOULD BE AT LEAST 2 INCHES BELOW BOTTOM OF FOOTING AT THE HIGHEST POINT AND SLOPE DOWNWARD TO A POSITIVE GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPING. REINFORCING STEEL PER STRUCTURAL DRAWINGS PROVIDE POSITIVE SLIP JOINT BETWEEN SLAB AND WALL. FLOOR SLAB FOOTING OR PAD MINIMUM PROVIDE PVC SHEETING 7 GLUED TO FOUNDATION t WALL TO REDUCE MOISTURE PENETRATION 1:1 BOTTOM IS GREATER) 4—INCH DIAMETER PERFORATED DRAIN PIPE. THE PIPE SHOULD BE LAID IN A TRENCH WITH A MINIMUM SLOPE OF 0.5 PERCENT. Exterior Foundation Wall Drain Job No. GS-3808 Fig. 5 CTL/Thompson, Inc. 1971 West 12th Avenue Denver, Colorado 80204 (303) 825-0777 Commercial Testing Laboratories, Inc. 22 Lipan Street Denver, Colorado 80223 (303) 825-0777 CTL/Thompson, Inc. 5240 Mark Dabling Blvd. Colorado Springs, Colorado 80918 (719) 528-8300 CTL/Thompson, Inc. 234 Center Dr. Glenwood Springs, Colorado 81601 (970) 945-2809 CTL/Thompson, Inc. 375 E. Horsetooth Rd. The Shores Office Park Building 3, Suite 100 Ft. Collins, Colorado 80525 (970) 206-9455 CTL/Thompson, Inc. 4718 N. Elizabeth Street, Suite C-2 Pueblo, Colorado 81008 (719) 595-1287 C0 COVER SHEET 110 NEALE AVENUE ASPEN, CO RO A R I N G F O R K E N G I N E E R I N G 59 2 H I G H W A Y 1 3 3 CA R B O N D A L E C O L O R A D O , 8 1 6 2 3 PH : ( 9 7 0 ) 3 4 0 - 4 1 3 0 F : ( 8 6 6 ) 8 7 6 - 5 8 7 3 CHECKED BY: # DE S C R I P T I O N DA T E DR A W N B Y CONSTRUCTION DRAWN BY: JOB #: Of 5 2020-13 NOT FOR ADW RBG 11 0 N E A L E A V E N U E AS P E N , C O HP C S U B M I T T A L 0 5 / 2 7 / 2 0 2 0 HPC SUBMITTAL 5.27.2020 ' �'R d)8 ttel( JRSE �• .ed � I �� ... �• w i \ ��-^�-� Iowa �' - ♦ .-t--' @. �.! I ` � � r � ( \ `,'_ haft 'Yius wackern �•/,- ( �� � j( , atbi 'Park Regen :A3p n+ rr ,G'+ ' `� \\�Shatt Aim 7C 82 �` 0,1 1 •, ! ' • ••.... I '�•'•' D?tpp�al -• ram' Cowen Ov\rL)',' 4 tunne / ~ Traf 1 - ^ ,RBI;• or.. Sta, � $ �\ i` ' \ 'Ilk at 4 4 p. Mt 'sops fO(J�A \ Ss uF �- sP N , .' .. N .. i M . ^, 5CAI,L: l" 000' ° I T 5 T46 T44 IRR. a T38 �' CONTROL °T36 T37 i T40 V �,� - � T42 J O�G O`b STEEL T41 T35 POST a q w Oti0G� O E C. T34 OUTL �o^i 4 a T30 �Cb if �b ° �29 T26 T28 5 a ° j T24 T27 a T22 T23 T21 &._-#5 REBAR & CAP L.S.#25947 I,, T51 T49 T52 S T50 SO2O/ T53 T47 B LDER­(�D YP.) AREA DRAIN d CON PA t / T33 F.F. T32 7908.8' LOT 2 A 6' 15,160 S.F.f 0.348 AC.f MULTI LEVEL WOOD tiv & STONE FRAME HOUSE WITH BASEMENT q� 17 QUEEN STREET 110 NEALE AVENUE fE ° T. T20 WALK 4 �� STORM 7936.0' DRAIN (TYP.) 1 16 O T18 GG h CHIMNEY 7940.0' �G ti: F.F 7914.6; �6• SONCRETE PATIO a 4 & TOPOGRAPHIC SURVEY. LOT 2,114 NEALE/ 17QUEEN HISTORIC LOT SPLIT ACCORDING TO THE PLAT RECORDED MAY 29, 1998 IN PLAT BOOK 45 AT PAGE 17 CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO FENCE (TYP.) �. LOT 1 N r \ T54 N \ T55 T56 ,t #5 REBAR & CAP - RIDGE L.S. 25 47 r 7933.9' I ,q I GATI N C NTROL TYP.) rn W LL (I T57 8 `\ / T17 �,O T59 d T 15 ° 4 UPPER LEVEL PARCEL 2 CONCRETE ti� PLAT BK 13 PG 35 F.F. DECK T 13 d ° 7903.6' T60 t9 BOULDER \, T12 ° n a ll 8" WALL (TYP.) T61 T14 "I \ 4 '7903 < �2� �~C T69 BELOW T9 `•, a 4 -#4 REBAR `� T11 a �. 4 ° GA 171) G� q T8 a 4 M ER tiXAft BO R 2 qq� T7 T1\ T6 ° 3 ° �ti 0.4 ' STONELL (TYP.) �00 Wyk O WATERLINE °. FA CIA (TYP.) T5 d Co a DRIVE TE G vtV og X T4 WATER 3 4 ° 1,011 fG D 3Qo SERVICE s GASLINE (TYP.) T3 T70 2� T68 ° BOULDER �J '- ° g. T WALL (TYP.) % SIGN s%- (TYP.) s T2 a > T66 G 8 \ ° ° 3 Tl 4t SINGLE LEVEL WOOD ° \ of /o9 4 G ° ELECTRIC & STONE FRAME ADU f STORV�DRAIN ss \ cT �qlj ��LFA T d RIM 7902S0' FLAGSTONE ; T67 ° 4 O T \ BOTT°7889.124G 6 F F. �^� ° q' 7904.1' G, 4- NORM �s a \ ss \ \ a RIM 7901 4' t RIDGE ° �rt 4 a a INV 7898. 4' GAS G' �17918.4' MAIL ° zn BOTT 78 aiSMETER a ° 0 LG(f�� \ r BOX �� f3 D ELE 4 0' 111 a MET RS ° FENCE " °F T71 ) ° C ��A ��� T T78 T77 d �TYP. cc�! 330 30 e y lY ����T �o E E v 1 \ s 9l q GRAVEL of T76 ,+ h �p�[I�� PARKING T75 AN- JUL` O � 60 \ \ T � \ \ \ T74 T / g YG 35 r cry o� ss \ S. 4LA�B 4C)00 U `\ \ \ TELE. OF�O �� �% 270 090 E \ \ \ W T PED.. CC 9 LIC��S 4g c o S � \ \ GASLINE \CATV Ex-UE T73 ­1 Q \\\ \ °s / GF 120 `\\ \ WMAIL \ WATERLINE EASEMENT \ r/ BOX � �. PER BK 340 PG 1 150 \ #5 REBAR - TBM \ c EL=7903.71' PROPERTY DESCRIPTION LOT 2,114 NEALE/17QUEEN HISTORIC LOT SPLIT, ACCORDING TO THE PLAT RECORDED MAY 29, 1998 IN PLAT BOOK 45 AT PAGE 17, CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO. NOTES: 1) THIS PROPERTY IS SUBJECT TO RESERVATIONS, RESTRICTIONS, COVENANTS, BUILDING SETBACKS AND EASEMENTS OF RECORD, OR IN PLACE AND EXCEPTIONS TO TITLE SHOWN IN THE TITLE COMMITMENT PREPARED BY ATTORNEYS TITLE INSURANCE AGENCY OF ASPEN, LLC AND FIRST AMERICAN TITLE INSURANCE CO. INC. COMMITMENT NO. 16003515, DATED EFFECTIVE APRIL 20, 2016. 2) THE DATE OF THIS SURVEY WAS APRIL 27, 2016 AND SEPTEMBER 18, 2018. 3) BASIS OF BEARINGS FOR THIS SURVEY IS A BEARING OF S50-20'03"E BETWEEN THE NORTHWESTERLY CORNER OF LOT 2, A #5 REBAR & CAP L.S. #25947 FOUND IN PLACE AND THE NORTHEASTERLY CORNER OF LOT 2, A #5 REBAR & CAP L.S. #25947 FOUND IN PLACE. 4) UNITS OF MEASURE FOR ALL DIMENSIONS SHOWN HEREON IS U.S. SURVEY FEET. 5) THIS SURVEY IS BASED ON THE 114 NEALE/17QUEEN HISTORIC LOT SPLIT SUBDIVISION EXEMPTION PLAT RECORDED MAY 29, 1998 IN PLAT BOOK 45 AT PAGE 17 AND THE BOUNDARY AGREEMENT PLAT RECORDED APRIL 29, 1982 IN PLAT BOOK 13 AT PAGE 35 IN THE PITKIN COUNTY CLERK AND RECORDER'S OFFICE AND CORNERS FOUND IN PLACE. 6) BUILDING SETBACKS ACCORDING TO THE CITY OF ASPEN LAND USE CODE FOR R-15A 26.710.060 ARE AS FOLLOWS: FRONT YARD SETBACK RESIDENTIAL DWELLING = 25' ACCESSORY AND ALL OTHER BUILDINGS = 30' SIDE YARD SETBACK = 10' REAR YARD SETBACK RESIDENTIAL DWELLING = 10' ACCESSORY AND ALL OTHER BUILDINGS = 5' BUILDING SETBACKS SHOULD BE VERIFIED WITH THE CITY OF ASPEN PLANNING DEPARTMENT PRIOR TO ANY PLANNING OR CONSTRUCTION. 7) ELEVATIONS AS SHOWN ARE BASED ON A GPS OBSERVATION UTILIZING THE WESTERN COLORADO RTVRN GPS NETWORK (1988 ORTHO DATUM) YIELDING AN ONSITE ELEVATION OF 7903.71' ON THE SOUTHEASTERLY CORNER OF LOT 2. CONTOUR INTERVAL EQUALS 1 FOOT. 8) ACCORDING TO FEMA PANEL NO. 08097CO204C, DATED JUNE 04, 1987 THE SUBJECT PROPERTY IN NOT WITHIN THE 100 YEAR FLOODPLAIN. IMPROVEMENT SURVEY STATEMENT I HEREBY STATE THAT THIS IMPROVEMENT SURVEY WAS PREPARED BY PEAK SURVEYING, INC. FOR 17 QUEEN LLC, A COLORADO LIMITED LIABILITY COMPANY. I FURTHER STATE THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE, APRIL 27, 2016 AND SEPTEMBER 18, 2018, EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ANY PART OF SAID PARCEL, EXCEPT AS NOTED. I FURTHER STATE THAT I HAVE EXAMINED THE TITLE COMMITMENT PREPARED BY ATTORNEYS TITLE INSURANCE AGENCY OF ASPEN, LLC AND FIRST AMERICAN TITLE INSURANCE CO. INC. COMMITMENT NO. 16003515, DATED EFFECTIVE APRIL 20, 2016 AND FIND ALL EXCEPTIONS TO TITLE THAT AFFECT THE SUBJECT PROPERTY ARE SHOWN HEREON TO THE BEST OF MY KNOWLEDGE AND BELIEF. ERROR IN CLOSURE FOR THIS SURVEY IS LESS THAN 1:15,000. C6 BY: SON 1� II,, P.L O: 379 b : 3793 : x 10/22/18 J� s� j0NA L .... � SLOPE TABLE NUMBER MIN. SLOPE MAX. SLOPE COLOR AREA 1 0.001% 20.000% 10437.85 2 20.000% 30.000% 1975.24 3 30.000% + 2746.91 TREE # TREE TYPE TRUNK DIA DRIP LINE BASE ELEV Tl BLUE SPRUCE 6" 8' 7902.1' T2 BLUE SPRUCE 8" 8' 7902.2' T3 BLUE SPRUCE 4" 6' 7903.3' T4 COTTONWOOD 8" 12' 7901.6' T5 BLUE SPRUCE 6" 8' 7902.1' 'M BLUE SPRUCE 6" 8' 7902.6' TT COTTONWOOD 12" 12' 7901.5' TS COTTONWOOD 6" 10' 1 7901.5' T9 COTTONWOOD 6" 10, 7901.9' T10 COTTONWOOD 6" 10, 7901.9' T11 BLUE SPRUCE 8" 8' 7902.3' T12 BLUE SPRUCE 8" 8' 7902.5' T13 COTTONWOOD 16" 20' 7902.1' T14 PINE 4" 6' 7901.3' T15 BLUE SPRUCE 8" 8' 7903.1' T16 BLUE SPRUCE 8" 8' 7904.1' T17 BLUE SPRUCE 3" 6' 7903.6' T18 DECIDUOUS 4" 15, 7904.4' T19 ASPEN 4" 8' 7904.8' T20 BLUE SPRUCE 6" 10, 7904.6' T21 ASPEN 3" 6' 7904.3' T22 PINE 8" 10, 7905.5' T23 DECIDUOUS 4" 8' 7905.4' T25 ASPEN 8" 10, 7905.6' T26 ASPEN 3" 6' 7906.7' 727 ASPEN 4" 6' 7906.6' T28 BLUE SPRUCE 3" 4' 7906.6' T29 PINE 8" 10, 7906.7' T30 PINE 6" 8' 7906.8' T31 ASPEN 6" 10, 7906.4' T32 ASPEN 3" 6' 7906.6' T33 ASPEN 51, 8' 7906.8' T34 ASPEN 4" 10, 7908.3' T35 ASPEN 3" 4' 7909.7' T36 ASPEN 6" 8' 7909.3' T37 ASPEN 6" 8' 7909.3' T38 BLUE SPRUCE 10" 10, 7910.7' T39 ASPEN 6" 8' 7910.3' T40 ASPEN 4" 6' 7911.9' T41 COTTONWOOD 8" 15' 7912.7' T42 ASPEN 3" 6 7913.2' T43 ASPEN 3" 6' 7913.5' T44 PINE 6" 8' 7912.7' T45 ASPEN 4" 6' 7912.0' T46 BLUE SPRUCE 3" 5' 7913.4' T47 PINE 12" 10, 7918.7' T49 4 DECIDUOUS 8" 8' 7915.1' T49 PINE 6" 8' 7919.3' T50 PINE 8" 10, 7919.3' T51 BLUE SPRUCE 101, 10, 7919.5' T52 BLUE SPRUCE 4" 15, 7919.9' T53 BLUE SPRUCE 3" 4' 7919.6' T54 BLUE SPRUCE 12" 15, 7920.4' T55 BLUE SPRUCE 14" 15, 7920.4' T56 ASPEN 8" 10, 7920.5' T57 PINE 14" 15, 7920.7' T58 ASPEN 6" 8' 7918.3' T59 PINE 6" 8' 7914.1' T60 BLUE SPRUCE 6" 8' 7913.8' T61 BLUE SPRUCE 6" 8' 7913.4' T62 PINE 6" 8' 7912.4' T63 PINE 6" 8' 7911.7' T64 PINE 2" 4' 7911.2' T65 PINE 2" 4' 7912.1' T66 PINE 4" 6' 7911.9' T67 3 ASPEN 2" 6' 7911.5' T68 ASPEN 3" 6' 7903.3' T69 BLUE SPRUCE 3" 8' 7903.0' T70 BLUE SPRUCE 4" 6' 7903.1' T71 PINE 4" 6' 7906.0' T72 ASPEN 8" 10, 7907.6' T73 BLUE SPRUCE 2" 5' 7903.6' T74 ASPEN 3" 6' 7902.9' T75 BLUE SPRUCE 2" 4' 7902.7' T76 BLUE SPRUCE 4" 6' 7902.9' T77 CEDAR 1 3" 1 2' 7902.8' T78 BLUE SPRUCE 1 6" 1 8' 7902.3' 180 \ \ \ \ C.O.A. CONTROL w Sury ey i n 4- Drawn By. 4e�. Date Revision B 17 QUEEN, LLC Project NO. S \ � s � \ 44 BEARS Inc.jhCJRN 1 10/19/18 UPDATE SLOPE TABLE JRN GRAPHIC SCALE S32�o'i'Qo"W 387.54' N" Checked By: CITY OF ASPEN, COLORADO 16029B P.O. Box 1746 2 10/22/18 UPDATE SLOPE TABLE JRN 5 10 10 40 Rifle, CO 81650 JRN IMPROVEMENT & TOPO SURVEY ss\ \ Phone (970) 625-1954 Date: LOT 2, 114 NEALE/17 UEEN HISTORIC Computer Fax (970) 579-7150 SEPT 27, 2018 ( IN FEET) \ www.peaksurveyinginc.com P LOT SPLIT- 110 NEALE AVE. I OF 1 _�F,x�Dr r*T� 1 inch = 10 ft. � � l 029eIMPTOPO � Snce 200 7 � G G E G E G C1 SITE PLAN RO A R I N G F O R K E N G I N E E R I N G 59 2 H I G H W A Y 1 3 3 CA R B O N D A L E C O L O R A D O , 8 1 6 2 3 PH : ( 9 7 0 ) 3 4 0 - 4 1 3 0 F : ( 8 6 6 ) 8 7 6 - 5 8 7 3 CHECKED BY: # DE S C R I P T I O N DA T E DR A W N B Y CONSTRUCTION DRAWN BY: JOB #: Of 5 2020-13 NOT FOR ADW RBG 11 0 N E A L E A V E N U E AS P E N , C O HP C S U B M I T T A L 0 5 / 2 7 / 2 0 2 0 G G E G E G C2 GRADING & DRAINAGE RO A R I N G F O R K E N G I N E E R I N G 59 2 H I G H W A Y 1 3 3 CA R B O N D A L E C O L O R A D O , 8 1 6 2 3 PH : ( 9 7 0 ) 3 4 0 - 4 1 3 0 F : ( 8 6 6 ) 8 7 6 - 5 8 7 3 CHECKED BY: # DE S C R I P T I O N DA T E DR A W N B Y CONSTRUCTION DRAWN BY: JOB #: Of 5 2020-13 NOT FOR ADW RBG 11 0 N E A L E A V E N U E AS P E N , C O HP C S U B M I T T A L 0 5 / 2 7 / 2 0 2 0 C3 DRAINAGE BASINS RO A R I N G F O R K E N G I N E E R I N G 59 2 H I G H W A Y 1 3 3 CA R B O N D A L E C O L O R A D O , 8 1 6 2 3 PH : ( 9 7 0 ) 3 4 0 - 4 1 3 0 F : ( 8 6 6 ) 8 7 6 - 5 8 7 3 CHECKED BY: # DE S C R I P T I O N DA T E DR A W N B Y CONSTRUCTION DRAWN BY: JOB #: Of 5 2020-13 NOT FOR ADW RBG 11 0 N E A L E A V E N U E AS P E N , C O HP C S U B M I T T A L 0 5 / 2 7 / 2 0 2 0 G G E G E G C4 UTILITY PLAN RO A R I N G F O R K E N G I N E E R I N G 59 2 H I G H W A Y 1 3 3 CA R B O N D A L E C O L O R A D O , 8 1 6 2 3 PH : ( 9 7 0 ) 3 4 0 - 4 1 3 0 F : ( 8 6 6 ) 8 7 6 - 5 8 7 3 CHECKED BY: # DE S C R I P T I O N DA T E DR A W N B Y CONSTRUCTION DRAWN BY: JOB #: Of 5 2020-13 NOT FOR ADW RBG 11 0 N E A L E A V E N U E AS P E N , C O HP C S U B M I T T A L 0 5 / 2 7 / 2 0 2 0