Loading...
HomeMy WebLinkAbout277 Bleeker Revised Application.20201208 418 E. Cooper Ave, Suite 201 | Aspen, Colorado | 81611 | 970.925.2252 December 8, 2020 Amy Simon, Historic Preservation Officer City of Aspen Community Development Department 130 S Galena Street, 3rd Floor Aspen, CO 81611 RE: 227 E. Bleeker Street Parcel ID: 2737 07 32 0014 Dear Amy, Thank you for your time and assistance with this application to seek HPC approval for the restoration, renovation and addition to the small home located on 227 East Bleeker Street. This property is in the R-6 zone district; and was part of a Lot Split in 2005 that allows it 1800 sq. ft. of Floor Area. This little home has been suffering demolition by neglect for a very long time. It will be completely restored to its historic appearance; squared up and made structurally sound again with a modest addition to the rear. We are keeping it in the same location on the lot as it was historically; with a basement under it now. We look forward to working with you and the Historic Preservation Commission on the restoration of this little home. RELEVANT LAND USE CODE SECTIONS SECTION 26.304 1. Please see attached letter of authorization from Mark Friedland, the manager of the 227 East Bleeker Street, LLC; granting Kim Raymond Architecture + Interiors, authority to act on their behalf throughout this process. 418 E. Cooper Ave, Suite 201 | Aspen, Colorado | 81611 | 970.925.2252 2. Please see the attached Vicinity Map with a legal description and directions to the property. 3. Please see the attached Title Insurance, Schedule A & B for proof of ownership. 4. Please see attached Site Plan 5. Please see the current survey of the property located at 227 E Bleeker Street. 6. Please also find attached all the forms for this Land Use Application. 7. Please see below, the description and summary of all requested information pertaining to the Land Use Code sections in regard to the proposed development. Additionally, please find a copy of the Pre-application Conference Summary sheet, attached at the end of this packet of information. This application package includes all requested documents as outlined by Amy Simon in the letter dated 9.22.20. SECTION 26.310.60 We will provide the posting and mailing to all the property owners within the 300’ radius of this parcel. The posting and mailing will happen at least 15 days prior to the hearing. The list of property owners is attached. SECTION 26.415.070D Historic Preservation – Major Development Certificate of Appropriateness for major development 1. This project is a major development as we are altering/repairing more than three elements of the historic building; and expanding the building by more than 250 sq. ft. 2. We will be presenting to just the HPC with this application. 3.a This application for Conceptual Review will include the following: 1. General application information and forms 2. Site plan and survey, showing existing and proposed conditions. 3. Scaled drawings showing the structure; existing and proposed addition; massing, height, scale, etc; floor and roof plans and elevations. 4. Primary materials; samples or photos at final review 5. Supplemental material to show context surrounding the historic resource: photos and 3D computer model. 6. Confirmation that the proposed building meets the RDS; per Section 26.410. The proposed building is a small historic miner’s cabin. By virtue of the size and location, and the fact that it is being restored to its original appearance, it meets the RDS by strict compliance with all standards or by flexible “intent”. Please see attached RDS checklist: 418 E. Cooper Ave, Suite 201 | Aspen, Colorado | 81611 | 970.925.2252 B1. Building Orientation: House sits on lot, parallel to street, with front door facing street B2/3. Garage is accessed from the alley, has one garage door and garage element is less wide than the historic cabin. B4. Cabin has a front porch open on two sides on front facade which is more than 50 sq. ft. The front of the home is only one story. B5. The historic cabin has an original, primary window that is 7’-3” wide x 7’-0 tall. It is proportionately large for the size of the cabin. -Window wells are set back from the front facade -Materials are compliant, with “heavier” materials lower on the elevations, and lighter materials above them. Materials are simple and minimal. - There is a connecting link that is 10’ long, less than 10’ tall and it is less than 10’ wide We meet the RDS as outlined in this section. 3.b/c All procedures of this section shall be followed for final approval. 4. Final development plan review: All procedures for this section shall be followed and addressed. Samples of materials will be presented. SECTION 26.415.090 Relocation of Designated Historic Properties This application is not seeking to re-locate the historic resource. The proposed plan leaves the historic house in its original location; but we are straightening it out on the site when we place it back on the new foundation . The elevation of the main level floor will be the same as the historic. We are proposing the addition of a full basement under the resource and the new addition. SECTION 26.415.110 Historic Preservation – Benefits Section 26.415.110.C Variations This project is seeking the following variations from the HPC, as provided for in this section. 1. development in the side, rear or front setbacks: a. We are seeking setback variations for the rear yard setback. For below grade living space, we are proposing aligning the foundation under the garage, so need a variance for 3’-2”. For the deck above the garage and the roof overhang that becomes a privacy screen, down to the deck, we are asking for a variance of 3’-3”. Thus the rear yard setback will be 6’-9” instead of 10’. All above grade, interior living space is within the 10’-0” setback. 418 E. Cooper Ave, Suite 201 | Aspen, Colorado | 81611 | 970.925.2252 The garage itself, which can be to the 5’ setback lin e is held back to 6’-9” from the rear property . On the historic cabin, the front yard setback has the existing bay window and it’s roof extending into the setback by 1’-11 ½”. Thus we need a variation for the front yard set back to be 8’-0 ½”. The historic home, in its original/historic location is well within the setbacks for the side and rear yards. To grant a variation the HPC must find that the proposed development is similar in pattern, features and character of the historic property and/or Enhances or mitigates an adverse impact to the historic significance or architectural character of the historic property, an adjoining designated historic property or historic district. The garage is well within the rear yard setback allowed for garages on an alley, 6’-9” from the property line. The foundation wall below it, is beyond the rear yard setback for living space. This below grade area will not be visible to the public and will not add additional impact to the neighbors. Factors to consider: 1. The historic cabin is remaining in it’s historic location, within the 10’ front yard setback. 2. The proposed addition is behind a 10’ long, less than 10’ wide linking element, which is more than 2’ from the east corner and 14’-6” from the west side of the rear of the cabin; leaving exposed a large portion of the historic building. 3. The addition is 8 feet more narrow than what would be allowed by the side yard setbacks, leaving more open space on the rear of the property; creating a smaller mass. 4. The garage is held back more than the required 5’ from the rear property line, providing a more open feel. 5. The roof overhang at the portion of the deck that is within the 10’ setback is beyond the 18” allowed for overhangs, so we can provide some solar protection for the interior space and add an interesting architectural element. This provides privacy from and for the large home to the West that is much larger in scale and also has a large deck at the rear. We are proposing to renovate and restore this little cabin that is decades into “demolition by neglect” to it’s historic, original appearance. We have historic photos and the physical structure to guide us in this complete renovation. This will completely enhance this historic cabin and mitigate the neglect and unsightly additions. For these reasons, we believe that this project meets the criteria to receive the setback variances for the rear yard setback and the allowable floor area bonus of 250 Sq. Ft. The exact variations and bonus are as follows: 418 E. Cooper Ave, Suite 201 | Aspen, Colorado | 81611 | 970.925.2252 Rear yard setback of 10’-0” at the basement is reduced to 6’-10” setback; a variation of 3’-2”. A portion of the deck above the garage and the roof overhang and side wall are 6’-9” from the rear property line; a variation of 3’-3”. The historic cabin has a bay window that extends 1’-11 ½”; thus 8’-01/2” front yard setback. The full extent of the 250 sq. ft. of an available bonus for exceptional renovation. SECTION 26.575.020 Calculations and Measurements The proposed development meets all of the requirements and restrictions of the calculations and measurements section of this code; except for the variances that are being sought with this application for the rear yard setback. Please see the attached Site plan, floor plans, elevations and FAR calculations. SECTION 26.710.040 R-6 Medium Density Residential Zone District R6 typically allows for 2820 Sq. Ft. on a 4500 Sq. Ft. lot; But due to a Lot Split agreement, this parcel is allowed only 1800 Sq. Ft. of FAR. with a bonus option of an additional 250 Sq. Ft from HPC approvals. The building is below the required 25’ Height limit; has the required 4500 Sq. Ft. of lot area; and is exempt from the pedestrian amenity. The proposed building complies with all requirements and restrictions for R-6. Section 10.4 of the Historic Preservation Guidelines The historic resource is the focus of the property, the entry point, and the predominant structure as viewed from the street. The addition to this miner’s cabin is very sensitive to the little cabin. The link at the rear of the cabin, covering a very small portion of the rear of the cabin, putting the addition well behind the cabin. The height of the addition is minimal, and the form and fenestration are similar to the cabin. This project complies with more than 2 of the requirements for allowing the addition to a historic resource to be larger than 100% of the size of the resource: 1. The cabin is visually dominant on the lot, extending almost to the extent of the side yard setbacks on the lot, and is distinguishable against the addition. The materials of the cabin will be restored to the original wood siding; the new wood and metal siding will be more modern in detail. 2. The foot print of the addition is very closely related to the size of the cabin and is sensitive to its scale and proportions. The foot print of the historic cabin 1100 sq. ft., including the front porch is 1232 sq. ft. The foot print of the addition is 725 sq. ft; 41% smaller than the footprint of the cabin. The proposed roof is the same pitch as the main gable of the cabin. 3. The interior of the historic resource is fully utilized; the entry door is remaining the entry to the home; the cabin will contain the public spaces 418 E. Cooper Ave, Suite 201 | Aspen, Colorado | 81611 | 970.925.2252 for this new home. The proposed home uses the same number of usable floors in the cabin as in the historic use. 4. We are demolishing 2 small additions that were added at some point to the front of the cabin or enclosing the porch, and an addition to the rear, exposing the historic rear wall except for the small attachment of the linking element; which is 9’-3” wide where it connects to the historic In summary, we believe that this project meets the criteria for the granting of approval of the addition to the historic cabin and the variances as described above due to the sensitive design of the addition; keeping it discreetly behind the renovated/restored cabin. We are meeting all of the Residential Design Standards that are applicable to this project and have met all of the Historic Preservation guidelines. We look forward to working with the HPC on this project and keeping this unique little home from further demolition by neglect. Thank you for your consideration of this project. Respectfully yours, Kim Raymond Kim Raymond AIA Kim Raymond Architecture + Interiors Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A 0.1 12/4/20 GENERAL INFORMATION DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 CONTRACTOR - - STRUCTURAL ENGINEER - - CIVIL ENGINEER - - MECHANICAL ENGINEER G.1.01 GENERAL INFORMATION A.1.01 EXISTING: SITE PLAN A.1.02 PROPOSED: SITE PLAN A.1.03 PROPOSED: LANDSCAPE PLAN A.1.04 EXISTING: FAR CALCULATIONS A.1.05 PROPOSED: FAR CALCULATIONS A.2.00 EXISTING: MAIN LEVEL PLAN A.2.01 EXISTING: ROOF PLAN A.2.02 PROPOSED: LOWER LEVEL PLAN A.2.03 PROPOSED: MAIN LEVEL PLAN A.2.04 PROPOSED: UPPER LEVEL PLAN A.2.05 PROPOSED: ROOF PLAN A.3.01 EXISTING ELEVATIONS: NORTH & EAST A.3.02 EXISTING ELEVATIONS: SOUTH & WEST A.3.03 PROPOSED ELEVATIONS: NORTH & EAST A.3.04 PROPOSED ELEVATIONS: SOUTH & WEST A.4.01 EXISTING BUILDING SECTIONS A.4.02 EXISTING BUILDING SECTIONS A.4.03 EXISTING BUILDING SECTIONS A.4.04 PROPOSED BUILDING SECTIONS A.4.05 PROPOSED BUILDING SECTIONS A.4.06 PROPOSED BUILDING SECTIONS - - 13 4 2 1 A7.1 LOCATION KIM RAYMOND ARCHITECTS, INC. 802 EAST COOPER AVE #4 ASPEN, CO 81611 970-925-2252 ARCHITECT 227 E. BLEEKER ABBREVIATIONS MATERIAL LEGEND VICINITY MAP PROJECT TEAMAPPLICABLE CODES PROJECT DATA SHEET INDEX (CONTINUED) SHEET INDEXSYMBOL LEGEND Subdivision: CITY AND TOWNSITE OF ASPEN Block: 120 Lot: F & G PARCEL ID NUMBER: ZONING: LOT SIZE: BLDG USE: OCC. GROUP: CONST. TYPE: CLIMATE ZONE: FIRE SPRINKLERS: LAND USE CATEGORY: TOWNSHIP: RANGE: SECTION: - - - - - - - - - - - - - - - - - - - - - - - - PLT. S.T.D.SLOPE TO DRAIN A A.B. A.F.F. A.F.G. A/C ABC ABS ABV. ACB ACOU. ACT ADD. AG AHU AL. or ALUM. ALT. ANL ASPH. AVG AWG B.M. B.N. B.O. B.O.F. B.U. B/C BD. BLDG BLK. BLKG. BM. BR BRG. BRZ C.A.P. C.D. C.I.P. C.J. C.O. C.T. CAB CAM. CCTV CEM. CER CFM CH CKT. BKR. CL or C.L. CLG. CLKG. CLO. CLR. CMU CNTRD. COL. COMB. CONC. CONST. CONT. CONTR. CU d D.F. D.G. D.S. D/W DBL. DEMO DIA. or Ø DIAG. DIM. DL DN. DR E.A. E.F. E.J. E.N. E.W. EA. EL ELECT. ELEV. EMC EMT ENT EQ. EQUIP. EST. EVAP. EWC EXC EXH. EXIST. or E EXT. F.A. F.C. F.C.O. F.D. F.E. F.N. F.O. F.S. F/G FAB. FACP FDC FDN. FHC FIN. FL FLG. FLUOR. FP FTG. FURN. G.I. GA. GALV. GAR. GFCI GFI GL GLB GM GM GRC GYP. GYP. BD. H.B. H.C. H.M. H/C HDBD. HDW HGT. HOR. HTR HVAC HW HYD. I.C. I.D. I.F. ID IG IMC IMPG INCL. INSUL. INT. J-BOX JCT JT. K-D KD KO L.E.D. L.FT. LAM LAT. LAV LD. LIN. LINO. LT. LTG. LVL M.B. M.H. M.I. M.O. MAR. MAS. MAT'L MAX. MECH. MED. MFG. MFR. MIN. MISC. MOD MTL. MUL N.I.C. N.T.S. NCM NFC NLR. NO. NOM. O.C. O.D. O.H. O.I. O.R. OAI OH OPNG. OPPO. P.C. P.L. P.LAM. P.O.C. PERP. or PH or Ø PL. PLAS. PLUMB. PLYWD. PORC. PERF. PREFAB. PSF PSI PTN. PVC PWR. Q.T. QTY. R R.D.L. R.D.O. R.O. R.O.W. or R/W REF REF. REINF. REQ'D. RET. REV. RM RMV. S.C. S.D. S.O.V. S/L S/S SC SCHED. SECT. SES SH SHT'G. SIM. SPA. SPECS SPKR. SQ. FT. SQ. IN. STC STD. STL. SUSP. SW SYM SYS. T & G T.B. T.M.B. T.O. T.O.B. T.O.C. T.O.F. T.O.J. T.O.M. T.O.S. T.O.W. T.S. T.V. TEL. TH. THD. THK. THRU TLT. TRANS. TYP. UNF. UR V.B. V.I.F. VA VERT. WC WDW WCT WP WT. W/ W/O WD. W.I. YD. AMPERES ANCHOR BOLT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR CONDITIONING AGGREGATE BASE COURSE ACRYLONITRILE-BUTADIENE-STYRENE ABOVE ASBESTOS-CEMENT BOARD ACOUSTIC ACOUSTICAL CEILING TILE ADDITION or ADDENDUM ABOVE GRADE AIR HANDLER UNIT ALUMINUM ALTERNATE ANNEALED ASPHALT AVERAGE AMERICAN WIRE GAUGE ANGLE BENCH MARK BOUNDARY NAILING BOTTOM OF BOTTOM OF FOOTING BUILT UP BACK OF CURB BOARD BUILDING BLOCK BLOCKING BEAM BRASS BEARING BRONZE CONCRETE ASBESTOS PIPE CONSTRUCTION DOCUMENTS CAST IN PLACE CONTROL JOINT CLEAN OUT CERAMIC TILE CABINET CAMBER CLOSED CIRCUIT TELEVISION CEMENT CERAMIC CUBIC FEET PER MINUTE CHANNEL CIRCUIT BREAKER CENTERLINE CEILING CAULKING CLOSET CLEAR CONCRETE MASONRY UNIT CENTERED COLUMN COMBINATION CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR COPPER PENNY DRINKING FOUNTAIN DECOMPOSED GRANITE DOWN SPOUT DISHWASHER DOUBLE DEMOLITION DIAMETER DIAGONAL DIMENSION DEAD LOAD DOWN DOOR EXPANSION ANCHOR EXHAUST FAN EXPANSION JOINT END NAILING EACH WAY EACH ELEVATION "ELECTRIC, ELECTRICAL" ELEVATOR ELECTRICAL METALLIC CONDUIT ELECTRICAL METALLIC TUBING ELECTRICAL NON-METALLIC TUBING EQUAL EQUIPMENT ESTIMATE EVAPORATIVE COOLER ELECTRIC DRINKING COOLER EXCAVATE EXHAUST EXISTING EXTERIOR FIRE ALARM FAN COIL FLOOR CLEAN OUT FLOOR DRAIN FIRE EXTINGUISHER FIELD NAILING FACE OF FLOOR SINK FIBERGLASS FABRICATE FIRE ALARM CONTROL PANEL FIRE DEPARTMENT CONNECTION FOUNDATION FIRE HOSE CABINET FINISH FLOOR FLOORING FLUORESCENT FIRE PROOF FOOTING FURNISH GALVANIZED IRON GAUGE GALVANIZED GARAGE GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT INTERRUPTER GLASS GLUE LAMINATED BEAM GRADE MARK GATE VALVE GALVANIZED RIGID TUBING GYPSUM GYPSUM BOARD HOSE BIBB HOLLOW CORE HOLLOW METAL HANDICAPPED HARDBOARD HARDWARE HEIGHT HORIZONTAL HEATER HEATING, VENTILATING & AIR CONDITIONING HOT WATER HYDRAULIC INTERCOM OUTLET INSIDE DIAMETER INSIDE FACE IDENTIFICATION ISOLATED GROUND INTERMEDIATE METALLIC CONDUIT IMPREGNATED INCLUDE, INCLUSIVE INSULATION INTERIOR JUNCTION BOX JUNCTION JOINT KNOCK DOWN KILN DRIED KNOCK OUT LIGHT EMITTING DIODE LINEAR FEET LAMINATE LATERAL LAVATORY LEAD LINEAR LINOLEUM LIGHT LIGHTING LAMINATED VENEER LUMBER MACHINE BOLT MANHOLE MALLEABLE IRON MASONRY OPENING MARBLE MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM MANUFACTURING MANUFACTURER MINIMUM MISCELLANEOUS MODULAR METAL MULLION NOT IN CONTRACT NOT TO SCALE NON-CORROSIVE METAL NOT FOR CONSTRUCTION NAILER NUMBER NOMINAL ON CENTER OUTSIDE DIAMETER OVER HANG ORNAMENTAL IRON OUTSIDE RADIUS OUTSIDE AIR INTAKE OVER HEAD OPENING OPPOSITE PRECAST CONCRETE PROPERTY LINE PLASTIC LAMINATE POINT OF CONNECTION PERPENDICULAR PHASE PLASTER PLATE PLASTIC PLUMBING PLYWOOD PORCELAIN PERFORATED PREFABRICATED POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PARTITION POLYVINYLCLORIDE POWER QUARRY TILE QUANTITY RADIUS ROOF DRAIN LEADER ROOF DRAIN OVERFLOW ROUGH OPENING RIGHT OF WAY REFRIGERATOR REFERENCE REINFORCED REQUIRED RETURN REVISION ROOM REMOVE SOLID CORE SMOKE DETECTOR SHUT OFF VALVE SKYLIGHT STAINLESS STEEL SELF CLOSING SCHEDULE SECTION SERVICE ENTRANCE SECTION SHEET SHEATHING SIMILAR SPACE SPECIFICATIONS SPEAKER SQUARE FEET SQUARE INCHES SOUND TRANSMISSION CLASS STANDARD STEEL SUSPENDED SWITCH SYMMETRICAL SYSTEM TONGUE AND GROOVE THROUGH BOLT TELEPHONE MOUNTING BOARD TOP OF TOP OF BEAM TOP OF CURB TOP OF FOOTING TOP OF JOIST TOP OF MASONRY TOP OF SLAB TOP OF WALL TUBE STEEL TELEVISION OUTLET TELEPHONE THRESHOLD THREADED THICK THROUGH TOILET TRANSFORMER TYPICAL UNFINISHED URINAL VAPOR BARRIER VERIFY IN FIELD VOLT AMPERE VERTICAL WATER CLOSET WINDOW WAINSCOT WEATHER PROOF WEIGHT WITH WITHOUT WOOD WROUGHT IRON YARD VCT VINYL COMPOSITION TILE JOISTJST. ALL CODES REFERENCED ARE TO BE USED AS AMENDED BY THE STATE OF COLORADO AND LOCAL JURISDICTION. NOTE: CODES BELOW ARE APPLICABLE ONLY IN AREAS. BECAUSE THE SCOPE OF WORK IS LESS THAN 40%, THE PROJECT IS NOT SUBJECT TO UPDATE TO CURRENT CODE -2015 INTERNATIONAL RESIDENTIAL CODE -2015 INTERNATION MECHANICAL CODE -2015 INTERNATIONAL PLUMBING CODE -2015 INTERNATIONAL FUEL & GAS CODE -2015 IECC (INTERNATIONAL ENERGY CONSERVATION CODE) - PITKIN COUNTY EFFICIENT BUILDING CODE -2014 NATIONAL ELECTRICAL CODE FINISH WOOD WOOD STUD BLOCKING STEEL STEEL STUD FRAMED WALL BATT INSULATION PLYWOOD CONCRETE STONE CMU SAND GRAVEL GWB COMPACTED SOIL SPRAY-FOAM INSULATION RIGID INSULATION GRID LINE BREAK LINE MATCH LINE REVISION A-701 ELEVATION MARKER SECTION MARKER DETAIL CUT DETAIL 1 A-501 ELEVATION D01 W01 ROOM NAME 101 INTERIOR ELEVATION MARKER ELEVATION NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER SHEET NUMBER ELEVATION NUMBER SPOT ELEVATION DOOR MARK WINDOW MARK ROOM NAME AND NUMBER 1 A-301 1 A-201 11 MAXIMUM FLOOR AREA: - - SQ FT ALLOWABLE DECK (15% OF MAX FLOOR AREA): - - SQ FT FRONT SETBACK: 10'-0" SIDE SETBACKS: 5'-0" REAR SETBACK: 10'/5''-0" MAXIMUM HEIGHT (PRINCIPAL STRUCTURE) (FT.): 25'-0" 227 E. BLEEKER STREET ASPEN, COLORADO 81611 Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A 1.01 12/4/20 EXISTING: SITE PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 7897 78 9 8 7 8 9 9 F F = 7 8 9 8 . 9 7 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T C O N C W A L K 5' - 0 " SE T B A C K 10'-0" SETBACK 10'-0" SETBACK 5' - 0 " SE T B A C K 1° EXISTING TRANSFORMER E. B L E E K E R S T R E E T SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E GM E M E E E E C C C C EE N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.02 12/4/20 PROPOSED: SITE PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 7897 78 9 8 7 8 9 9 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T E E C C B B A A 2 F F G G 1 3 D D H H 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 6'-8 3/4" 5'-0" 5' - 0 " 7' - 4 " 5' - 0 " 5' - 1 7 / 8 " 7' - 1 1 / 4 " 6' - 7 1 / 8 " 6'-10"82'-8 3/4"10'-5 1/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 25'-7"10'-0"47'-1 3/4" 11 ' - 0 1 / 8 " 26 ' - 8 1 / 4 " 7' - 5 1 / 4 " 5'-0"5'-0" 3' - 0 " 3'-0" E. B L E E K E R S T R E E T 8" : 1 2 " SL O P E 8" : 1 2 " SL O P E 8":12" SLOPE 8":12" SLOPE 7 1 / 2 " : 1 2 " SL O P E 7 1 / 2 " : 1 2 " SL O P E 7 1/2":12" SLOPE 7 1/2":12" SLOPE 7 1/2":12" SLOPE 7 1/2":12" SLOPE 4 PR O P E R T Y L I N E PROPERTY LINE SETBACK LINE SE T B A C K L I N E 12 " : 1 2 " SL O P E 12 " : 1 2 " SL O P E 1":12" SLOPE PA R K I N G S P A C E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.03 12/4/20 PROPOSED: LANDSCAPE PLAN DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T F CO N C R E T E PA V E R S GL A S S F L O O R PA T I O EXISTING TRANSFORMER E. B L E E K E R S T R E E T SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E PR O P O S E D AD D I T I O N PR O P O S E D AT T A C H E D GA R A G E PR O P O S E D LI N K PR O P O S E D HI S T O R I C BU I L D I N G PE R M E A B L E PA V E R S CONCRETE WALK CE R A M I C TI L E RA I S E D RA I N GA R D E N CO N C R E T E GA R A G E A P R O N AN N U A L FL O W E R GA R D E N AN N U A L F L O W E R G A R D E N ANNUAL FLOWER GARDEN WO O D DE C K I N G ANNUAL FLOWER GARDEN GRAVEL OR MULCH SOD PROPOSED BUILDING WOOD DECK CONCRETE WALKWAY PERMEABLE PAVER CERAMIC TILE GLASS FLOOR LANDSCAPE PLAN KEY N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.04 12/4/20 EXISTING FAR CALCULATIONS DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 RG F F EX I S T I N G TR A N S F O R M E R 1,538 sq ft SE T B A C K L I N E PR O P E R T Y L I N E SETBACK LINE PROPERTY LINE SCALE: 1/8" = 1'-0"1 EXISTING MAIN LEVEL FAR Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.05 12/4/20 PROPOSED FAR CALCULATIONS DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 W/DW/D 1 2 4 3 5 6 GLASS FLOOR ABOVE 2,635 sq ft PROPERTY LINE PR O P E R T Y L I N E SE T B A C K L I N E PR O P E R T Y L I N E PORCH: 132 sq ft PATIO:101 sq ft PORCH:21 sq ft F FF: 100'-2 1/4" = 7899.97'(100'-0" = 7898.78') EX I S T I N G TR A N S F O R M E R GARAGE FLOOR AREA 350 SQ FT TALL CABINET (BOOT WARMERS) BENCH W/ CUBBIES ABOVETALL CABINET (BOOT WARMERS) TRASH) SK I S T O R A G E R A C K BI K E S T O R A G E DN ST O R A G E ST O R A G E HA N G I N G WET BAR WINE CABINET STEP: 7 1/2"STEP: 4" DN DN 1,461 sq ft 364 sq ft= 57.0 sq ft SE T B A C K L I N E PR O P E R T Y L I N E SETBACK LINE PROPERTY LINE PARKING SPACE UP PARKING SPACE DN 7 1/2":12" SLOPE 7 1/2":12" SLOPE 7 1 / 2 " : 1 2 " SL O P E 7 1 / 2 " : 1 2 " SL O P E 7 1 / 2 " : 1 2 " SL O P E 7 1 / 2 " : 1 2 " SL O P E 439 sq ft 177 sq ft SE T B A C K L I N E PR O P E R T Y L I N E 12":12" SLOPE 12":12" SLOPE 1" : 1 2 " SL O P E 658 sq ft 998 sq ft355 sq ft 1 sq ft 2 sq ft 11 sq ft 273 sq ft 392 sq ft 2.3.1. 5.4.6. 27 sq ft 27 sq ft 14 sq ft23 sq ft SCALE: 1/8" = 1'-0"0 PROPOSED LOWER LEVEL FAR SCALE: 1/8" = 1'-0"1 PROPOSED MAIN LEVEL FAR SCALE: 1/8" = 1'-0"2 PROPOSED UPPER LEVEL FAR SCALE: 1/8" = 1'-0"0 PROPOSED LOWER LEVEL FAR - ELEVATIONS N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.06 12/4/20 PROPOSED: SCHEMATIC DRAINAGE PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T F CO N C R E T E PA V E R S GL A S S F L O O R PA T I O BE L O W - G R A D E S T O R M W A T E R AN D I N F I L T R A T I O N S Y S T E M (S T O R M T E C H O R S I M I L A R ) . SI Z E I S A P P R O X I M A T E A N D W I L L UL T I M A T E L Y B E B A S E D U P O N T H E RE Q U I R E D Q U A L I T Y C A P T U R E VO L U M E F O R T H E S I T E . ST O R M P I P E W I T H I N T E R M I T T E N T IN L E T S T O C O L L E C T D R A I N A G E FR O M T H E S I D E Y A R D . D O W N S P O U T S AL O N G T H E S I D E O F T H E H O M E WI L L B E R O U T E D T O T H I S P I P E . EXISTING TRANSFORMER E. B L E E K E R S T R E E T ST O R M P I P E W I T H I N T E R M I T T E N T IN L E T S T O C O L L E C T D R A I N A G E FR O M T H E S I D E Y A R D . D O W N S P O U T S AL O N G T H E S I D E O F T H E H O M E WI L L B E R O U T E D T O T H I S P I P E . TR E N C H D R A I N T O IN T E R C P E T R U N O F F FR O M D R I V E W A Y . SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E PR O P O S E D AD D I T I O N PR O P O S E D AT T A C H E D GA R A G E PR O P O S E D LI N K PR O P O S E D HI S T O R I C BU I L D I N G PE R M E A B L E PA V E R S CONCRETE WALK CE R A M I C TI L E RA I S E D RA I N GA R D E N CO N C R E T E GA R A G E A P R O N AN N U A L FL O W E R GA R D E N AN N U A L F L O W E R G A R D E N ANNUAL FLOWER GARDEN WO O D DE C K I N G STORMWATER STORAGE SCHEMATIC DRAINAGE PLAN KEY PERFORATED STORM PIPE TRENCH DRAIN Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.00 12/4/20 EXISTING: MAIN LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 7897 78 9 8 7 8 9 9 F F = 7 8 9 8 . 9 7 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T C O N C W A L K E. 5 E. 5 E E C C B B A A 2 1 3 D D RG F 5' - 7 7 / 8 " 11'-7 1/4" 5' - 0 " SE T B A C K 10'-0" SETBACK 10'-0" SETBACK 5' - 0 " SE T B A C K 1° EXISTING TRANSFORMER EXISTING TRANSFORMER BE D R O O M KI T C H E N BE D R O O M BA T H PA N T R Y ST O R A G E HA L L EN T R Y ST O R A G E LI V I N G R O O M DI N I N G R O O M E. B L E E K E R S T R E E T 4 SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.01 12/4/20 EXISTING: ROOF PLAN DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T C O N C W A L K E. 5 E. 5 E E C C B B A A 2 1 3 D D E. B L E E K E R S T R E E T AL L E Y 4 SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.02 12/4/20 PROPOSED: LOWER LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 E E C C B B A A 2 F F G G 2. 5 0 1 0 3. 5 0 3 D D 1. 5 H H W/ D W/ D 1'-10"3'-2" 82'-8 3/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 10'-5 1/4" 6' - 7 1 / 8 " 31 ' - 5 1 / 4 " 7' - 1 1 / 4 " 10 ' - 0 1 / 2 " 14 ' - 3 " 7' - 1 3 / 4 " 6'-10" 5'-0"5'-0" LA U N D R Y W. I . C . W. I . C . BA T H 3 BA T H 2 GL A S S F L O O R AB O V E GY M FA M I L Y R O O M BE D R O O M 3 BE D R O O M 2 BE D R O O M 1 BA T H 1 W. I . C . li n e n li n e n TV / FP? 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 3 A 5 . 2 3 A 5 . 2 5 A 5 . 2 5 A 5 . 2 4 A 5 . 2 4 A 5 . 2 PR O P E R T Y L I N E PROPERTY LINE SETBACK LINE PROPERTY LINE ME C H A N I C A L A N D ST O R A G E 4 6 A 5 . 3 6 A 5 . 3 7 A 5 . 3 7 A 5 . 3 8 A 5 . 3 8 A 5 . 3 N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.03 12/4/20 PROPOSED: MAIN LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 7897 78 9 8 7 8 9 9 CO N C R E T E S I D E W A L K E E C C B B A A 2 F F G G 2. 5 0 1 0 3. 5 0 3 D D 1. 5 H H F 6'-10"82'-8 3/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 10'-5 1/4" 6' - 7 1 / 8 " 31 ' - 5 1 / 4 " 7' - 1 1 / 4 " 10 ' - 0 1 / 2 " 14 ' - 3 " 7' - 1 3 / 4 " 25'-7"10'-0"47'-1 3/4" 11 ' - 0 1 / 8 " 26 ' - 8 1 / 4 " 7' - 7 " 9 1/4" 4" 2'-4 3/4" 1'-11 1/2" 3' - 0 " 3'-0" FF : 1 0 0 ' - 2 1 / 4 " = 7 8 9 9 . 9 7 ' (1 0 0 ' - 0 " = 7 8 9 8 . 7 8 ' ) 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 EXISTING TRANSFORMER GA R A G E PO R C H DI N I N G RO O M GA R A G E F L O O R A R E A 3 5 0 S Q F T BI G O P E N FI R E P L A C E AR T I S T I C FE A T U R E KI T C H E N LI V I N G R O O M PA T I O MU D RO O M TO MA S T E R TO LO W E R WE T BA R WI N E CA B I N E T PA N T R Y TA L L CA B I N E T (B O O T W A R M E R S ) BE N C H W / CU B B I E S A B O V E TA L L CA B I N E T (B O O T W A R M E R S ) TR A S H ) SKI STORAGE RACK BIKE STORAGE DN STORAGE STORAGE HANGING WE T BA R WI N E CA B I N E T ST E P : 7 1 / 2 " ST E P : 4 " DN DN 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 3 A 5 . 2 3 A 5 . 2 5 A 5 . 2 5 A 5 . 2 4 A 5 . 2 4 A 5 . 2 4 6 A 5 . 3 6 A 5 . 3 7 A 5 . 3 7 A 5 . 3 8 A 5 . 3 8 A 5 . 3 SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E PA R K I N G S P A C E UP F F = 7 8 9 8 . 9 7 PA R K I N G S P A C E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.04 12/4/20 PROPOSED: UPPER LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 E E C C B B A A 2 F F G G 2. 5 0 1 0 3. 5 0 3 D D 1. 5 H H 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 3'-3" 5' - 3 1 / 4 " 2' - 5 1 / 4 " 5' - 0 " 6'-10"82'-8 3/4"10'-5 1/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 6' - 7 1 / 4 " 31 ' - 5 1 / 4 " 7' - 1 1 / 4 " 10 ' - 0 1 / 2 " 14 ' - 3 " 7' - 1 3 / 4 " 6'-10"25'-7"10'-0"47'-1 3/4"10'-5 1/4" 31 ' - 1 1 / 4 " 7' - 5 1 / 4 " 1' - 4 " MA S T E R BE D R O O M W. I . C . DE C K DN MA S T E R B A T H 20 1 20 2 20 3 7 1 / 2 " : 1 2 " SL O P E 7 1 / 2 " : 1 2 " SL O P E 7 1/2":12" SLOPE 7 1/2":12" SLOPE 7 1/2":12" SLOPE 7 1/2":12" SLOPE 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 3 A 5 . 2 3 A 5 . 2 5 A 5 . 2 5 A 5 . 2 4 A 5 . 2 4 A 5 . 2 4 6 A 5 . 3 6 A 5 . 3 7 A 5 . 3 7 A 5 . 3 8 A 5 . 3 8 A 5 . 3 SETBACK LINE PROPERTY LINE 12 " : 1 2 " SL O P E 12 " : 1 2 " SL O P E 1":12" SLOPE N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.05 12/4/20 PROPOSED: ROOF PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 CO N C R E T E S I D E W A L K E E C C B B A A 2 F F G G 2. 5 0 1 0 3. 5 0 3 D D 1. 5 H H 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 6'-8 3/4" 5'-0" 5' - 0 " 7' - 4 " 5' - 0 " 5' - 1 7 / 8 " 7' - 1 1 / 4 " 6' - 7 1 / 8 " 6'-10"82'-8 3/4"10'-5 1/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 25'-7"10'-0"47'-1 3/4" 11 ' - 0 1 / 8 " 26 ' - 8 1 / 4 " 7' - 5 1 / 4 " 5'-0"5'-0" 3' - 0 " 3'-0" 8" : 1 2 " SL O P E 8" : 1 2 " SL O P E 8":12" SLOPE 8":12" SLOPE 7 1 / 2 " : 1 2 " SL O P E 7 1 / 2 " : 1 2 " SL O P E 7 1/2":12" SLOPE 7 1/2":12" SLOPE 7 1/2":12" SLOPE 7 1/2":12" SLOPE 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 3 A 5 . 2 3 A 5 . 2 5 A 5 . 2 5 A 5 . 2 4 A 5 . 2 4 A 5 . 2 4 6 A 5 . 3 6 A 5 . 3 7 A 5 . 3 7 A 5 . 3 8 A 5 . 3 8 A 5 . 3 PR O P E R T Y L I N E PROPERTY LINE SETBACK LINE SE T B A C K L I N E 12 " : 1 2 " SL O P E 12 " : 1 2 " SL O P E 1":12" SLOPE PA R K I N G S P A C E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.01 12/4/20 EXISTING ELEVATIONS: NORTH & EAST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 243 1 1' - 7 3 / 4 " 1' - 3 1 / 2 " T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" E.5 E C B AD T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"1 EXISTING NORTH ELEVATION SCALE: 1/4" = 1'-0"2 EXISTING EAST ELEVATION Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.02 12/4/20 EXISTING ELEVATIONS: SOUTH & WEST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 E.5ABCED 2' - 3 5 / 8 " 1' - 1 1 5 / 8 " T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 21 3 4 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"2 EXISTING WEST ELEVATION SCALE: 1/4" = 1'-0"1 EXISTING SOUTH ELEVATION Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.03 12/4/20 PROPOSED ELEVATIONS: NORTH & EAST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 23.50 2.5043 1 01.5 1' - 7 3 / 4 " 1' - 3 1 / 2 " T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" FG E C B ADH T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. UPPER LEVEL PLY 110'-0" TOP PLATE @ GABLE ROOFS 119'-2 1/4" SCALE: 1/4" = 1'-0"1 PROPOSED NORTH ELEVATION SCALE: 1/4" = 1'-0"2 PROPOSED EAST ELEVATION Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.04 12/4/20 PROPOSED ELEVATIONS: SOUTH & WEST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 A B C ED F G H 2' - 3 5 / 8 " 1' - 1 1 5 / 8 " T.O. MAIN LEVEL PLY 100'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. UPPER LEVEL PLY 110'-0" T.O. UPPER LEVEL PLY 110'-0" TOP PLATE @ GABLE ROOFS 119'-2 1/4" 2.5020 3.501341.5 T.O. LOWER LEVEL SLAB 88'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. LOWER LEVEL SLAB 88'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" TOP PLATE @ GABLE ROOFS 119'-2 1/4" TOP PLATE @ GABLE ROOFS 119'-2 1/4" SCALE: 1/4" = 1'-0"2 PROPOSED WEST ELEVATION SCALE: 1/4" = 1'-0"1 PROPOSED SOUTH ELEVATION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.01 12/4/20 EXISTING BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 24 13 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 7898.00' FF:7898.97' SCALE: 1/4" = 1'-0"2 EXISTING BUILDING SECTION SCALE: 1/4" = 1'-0"1 EXISTING BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.02 12/4/20 EXISTING BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 7 1 / 2 " 3 3 / 4 " T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 2 413 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"3 EXISTING BUILDING SECTION SCALE: 1/4" = 1'-0"4 EXISTING BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.03 12/4/20 EXISTING BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 E.5 BCE AD T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" E.5ABCED T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"5 EXISTING BUILDING SECTION SCALE: 1/4" = 1'-0"6 EXISTING BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.04 12/4/20 PROPOSED BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 T.O. BASEMENT SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-06" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" 24 133.50 2.50 01.5 T.O. BASEMENT SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" T.O. BASEMENT SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" 7898.00' FF:7898.97' SCALE: 1/4" = 1'-0"2 PROPOSED BUILDING SECTION 2 SCALE: 1/4" = 1'-0"1 PROPOSED BUILDING SECTION 1 Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.05 12/4/20 PROPOSED BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 7 1 / 2 " 3 3 / 4 " T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" 2.502 40133.501.5 T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" TOP PLATE @ GABLE ROOFS 119'-2 1/4" TOP PLATE @ GABLE ROOFS 119'-2 1/4" 1.501 2.502 3 3.50 4 T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" SCALE: 1/4" = 1'-0"3 PROPOSED BUILDING SECTION 3 SCALE: 1/4" = 1'-0"5 PROPOSED BUILDING SECTION 5 SCALE: 1/4" = 1'-0"4 PROPOSED BUILDING SECTION 4 Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.06 12/4/20 PROPOSED BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 BCEFG ADH T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" TOP PLATE @ GABLE ROOFS 119'-2 1/4" T.O. UPPER LEVEL PLY 110'-0" A B C E F GD H T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" TOP PLATE @ GABLE ROOFS 119'-2 1/4" SCALE: 1/4" = 1'-0"6 PROPOSED BUILDING SECTION 6 SCALE: 1/4" = 1'-0"7 PROPOSED BUILDING SECTION 7 Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.5.01 12/4/20 PORCH DETAIL DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 1' - 1 1 5 / 8 " 1' - 1 1 5 / 8 " 1' - 9 3 / 8 " 8 3 / 8 " 7 3 / 8 " 7 3 / 8 " FINISHED FLOOR 7899.97'= 100'-2 1/4" T.PLY 100'-0" FINISHED FLOOR 7899.97'= 100'-2 1/4" T.PLY 100'-0" PORCH 1 (NORTH WEST) NORTH ELEVATION PORCH 1 (NORTH WEST) WEST ELEVATION A B C 1' - 0 1 / 8 " 1' - 3 1 / 2 " 1' - 0 5 / 8 " ABC43 PORCH 2 (NORTH EAST) NORTH ELEVATION PORCH 2 (NORTH EAST) EAST ELEVATION FINISHED FLOOR 7899.97'= 100'-2 1/4" T.PLY 100'-0" 4 1 / 8 " 7 1 / 2 " FINISHED FLOOR 7899.97'= 100'-2 1/4" T.PLY 100'-0" 43 FINISHED FLOOR 7899.97'= 100'-2 1/4" T.PLY 100'-0" PATIO 99'-6 3/4" PATIO 99'-5 1/4" E D PATIO (SOUTH EAST) EAST ELEVATION PATIO (SOUTH EAST) SOUTH ELEVATION SCALE: 3/8" = 1'-0"1 PORCH 1: DETAIL 1 SCALE: 3/8" = 1'-0"2 PORCH 2: DETAIL 1 SCALE: 3/8" = 1'-0"3 PATIO: DETAIL 1 P.O. Box 3901 Eagle, Colorado 81631 YARNELL CONSULTING & CIVIL DESIGN, LLC (970) 323-7008 · 12/1/2020 229 Midland Ave. Basalt, Colorado 81621 227 E. Bleeker Street, Aspen, Colorado Page 1 of 2 Patricia Weber Kim Raymond Architects 418 East Cooper Avenue, Suite 201 Aspen, Colorado 81611 Patricia@KRAI.us Subject: 227 E. Bleeker Street, Aspen, Colorado Historic Preservation Committee Stormwater Management Review Patricia: I understand Aspen Starwood, LLC is pursuing the restoration of the historic miner’s cabin located on the subject property. Due to it being designated a historic monument within the city, work associated with the cabin requires review and approval by the Aspen Historic Preservation Committee (HPC). HPC requested that stormwater design be considered at Conceptual review. The intent of this letter is to accompany updates to the architectural site plan to fulfill said requirement. Based on the topographic data from Aspen Survey, the floor of the existing structure is approximately 12 inches higher than the back of sidewalk elevation along East Bleeker Street. However, the remainder of the existing site appears to sit low relative to the alley, East Bleeker Street and the easterly adjacent property. To improve the drainage condition and meet current engineering code, it is desired to fill the site to provide adequate positive drainage into East Bleeker Street and the alley. Without this approach, runoff from the rights-of-way could flow onto the property and potentially flood the home in a future large storm event. Redevelopment of the subject property to the extent desired falls under the requirements of a “Major Redevelopment” as defined within Chapter 1 of the City of Aspen Urban Runoff Management Plan (URMP). The primary component of this for the subject property will be providing the requisite water quality capture volume. While the architectural site plan currently shows incorporation of a rain garden into the project, it is unlikely to be viable to route the drainage from all the impervious areas on-site to this feature. Alternatively, it will likely just be able to capture runoff from roofs that are immediately adjacent and whose downspouts can drop to the rain garden. HPC regulations prohibit the construction of rain gardens in front of the historic building which further limits opportunities for on-grade water quality management. While deemed a “last resort” option, it is likely the project will need to incorporate a below-grade storage and infiltration system similar to StormTech. This will be further coordinated with the city’s Engineering Department. Per the URMP, no on-site detention or off-site drainage analysis will be required for this project since it is located in the Aspen Mountain drainage basin. As such, the below-grade system will be designed for small storm events with means of overflow into the rights-of-way for large storms. Please let me know if you have any further questions that I can answer regarding the anticipated stormwater management strategies for the redevelopment of the subject property. P.O. Box 3901 Eagle, Colorado 81631 YARNELL CONSULTING & CIVIL DESIGN, LLC (970) 323-7008 · 12/1/2020 229 Midland Ave. Basalt, Colorado 81621 227 E. Bleeker Street, Aspen, Colorado Page 2 of 2 Sincerely, Justin J. Yarnell, PE Colorado PE Number 47241