HomeMy WebLinkAboutA.1.06 PROPOSED_ SCHEMATIC DRAINAGE PLANScale: AS NOTED
ISSUE
HPC SET #1
227 E. BLEEKER
227 E. BLEEKER STREET
ASPEN, COLORADO 81611
1" ACTUAL
IF THE ABOVE DIMENSION DOES
NOT MEASURE ONE INCH (1")
EXACTLY, THIS DRAWING WILL
HAVE BEEN ENLARGED OR
REDUCED, AFFECTING ALL
LABELED SCALES.
ALL DESIGNS, IDEAS ARRANGEMENTS
A N D P L A N S I N D I C AT E D BY T H E S E
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
R AY M O N D A R C HIT E C T S, IN C . A N D
SHALL NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
W I T H O U T W R I T T E N P E R M I S S I O N .
W R I T T EN D I M E NS I ON S S HA L L TAK E
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
A .1.06
11/23/20
PROPOSED:
SCHEMATIC
DRAINAGE
PL AN
DATE
10/26/20
KIM RAYMOND ARCHITECTS, INC.
418 E. HYMAN AVENUE, SUITE 201
www.kimraymondarchitects.com
970-925-2252
CONCRETE SIDEWALK
EDGE OF PAVEMENT F
CONCRETE
PAVERS
GLASS FLOOR
PATIO
BELOW-GRADE STORMWATER
AND INFILTRATION SYSTEM
(STORMTECH OR SIMILAR).
SIZE IS APPROXIMATE AND WILL
ULTIMATELY BE BASED UPON THE
REQUIRED QUALITY CAPTURE
VOLUME FOR THE SITE.
STORM PIPE WITH INTERMITTENT
INLETS TO COLLECT DRAINAGE
FROM THE SIDE YARD. DOWNSPOUTS
ALONG THE SIDE OF THE HOME
WILL BE ROUTED TO THIS PIPE.
E. BLEEKER STREET
STORM PIPE WITH INTERMITTENT
INLETS TO COLLECT DRAINAGE
FROM THE SIDE YARD. DOWNSPOUTS
ALONG THE SIDE OF THE HOME
WILL BE ROUTED TO THIS PIPE.
TRENCH DRAIN TO
INTERCPET RUNOFF
FROM DRIVEWAY.
SETBACK LINE
PROPERTY LINE
SETBACK LINE
PROPERTY LINE
PROPOSED
ADDITION
PROPOSED
ATTACHED
GARAGE
PROPOSED
LINK
PROPOSED
HISTORIC
BUILDING
PERMEABLE
PAVERS
CONCRETE
WALK
CERAMIC
TILE
RAISED
RAIN
GARDEN
CONCRETE
GARAGE APRON
ANNUAL
FLOWER
GARDEN
ANNUAL FLOWER GARDEN
ANNUAL
FLOWER GARDEN
WOOD
DECKING
STORMWATER STORAGE
SCHEMATIC DRAINAGE PLAN KEY
PERFORATED STORM PIPE
TRENCH DRAIN