Loading...
HomeMy WebLinkAboutApplication.232 E Main 300 SO SPRING ST | 202 | ASPEN, CO 81611 970.925.2855 | BENDONADAMS.COM February 5, 2020 Ben Anderson Planner City of Aspen RE: 232 East Main Street; Aspen, CO Mr. Anderson: Please accept this amendment to a Growth Management development order for 232 East Main Street. The development order for this commercial project on Main Street was issued March 8, 2017, with an effective date of March 16, 2017. The all-commercial project will replace the existing Conoco gas station, increasing the net leasable area from 1,500 sf to approximately 4,818 sf. The increase in commercial net leasable area necessitates the provision of affordable housing. The Growth Management approval, HPC Resolution No. 3, 2017, specifies this obligation to be met through the provision of affordable housing certificates. The applicant is requesting this obligation be amended to allow the affordable housing to be provided in form of actual built units at the 834 West Hallam property (Poppies). The 834 project is fully entitled for a multi-family affordable housing development for which affordable housing credits would otherwise be issued by the City upon completion of the project. The applicant controls both properties (owned by different LLCs) and this request for an amendment to the 232 East Main Street approvals should be viewed in context with an amendment request to the 834 West Hallam Street approvals. The pre-application conference summary includes a statement regarding the prospective “CO link” between the 232 and 834 projects. “The applicant should be aware that once this amendment is established, under no circumstances will the CO for 232 E. Main be considered until the AH units at 834 W. Hallam have been issued a CO.” The applicant is aware and accepting of this CO link requirement. Issuance of a Certificate of Occupancy for the 232 project is contingent upon the 834 project being completed and issued a Certificate of Occupancy. The property is owned by 232 East Main Street LLC, a Colorado limited liability company. Mark Hunt is the manager and has authorized BendonAdams to submit this application. We hope this Page 2 of 2 300 SO SPRING ST | 202 | ASPEN, CO 81611 970.925.2855 | BENDONADAMS.COM application provides sufficient information to enable a thorough evaluation of this application. We are preparing a draft Notice of Approval for your consideration and will provide under a separate cover. Upon request, BendonAdams will gladly provide such additional information as may be required during your review. Sincerely, Chris Bendon, AICP BendonAdams LLC Exhibits: 1. Response to Review Criteria 2. Application Form 3. Agreement to Pay 4. HOA Form 5. Authorization to represent 6. Proof of ownership with statement of authority 7. Pre-Application Summary 8. Vicinity Map 9. Development Order 10. HPC Resolution No. 3, 2017 11. Select Sheets from Building Permit Set 12. Existing Net Leasable Exhibit 1 Page 1 Exhibit 1 Review Criteria 26.470.150. Amendment of a Growth Management Development Order. A. Insubstantial amendment. An insubstantial amendment to an approved growth management development order may be authorized by the Community Development Director if: 1) The change conforms to all other provisions of the Land Use Code and does not exceed approved variations to the residential design standards, require an amendment to the commercial design review approval or such variations or amendments have been approved. Response to 1: The 232 project’s design, layout, and uses are not changing. The project The amendment only affects the method of providing affordable housing mitigation – from delivery of affordable housing credits upon issuance of a building permit to delivery of affordable housing units prior to the issuance of a Certificate of Occupancy. The affordable housing units to be delivered will be developed at 834 West Hallam, a project that has received approvals to be developed as a multi-unit affordable housing project. 2) The change does not alter the number, size, type or deed restriction of the proposed affordable housing units, subject to compliance with the Aspen/Pitkin County Housing Authority Guidelines. Response to 2: The applicant is not requesting a change to the number or category of affordable housing to be provided. HPC Resolution No. 3, 2017 provided the growth management approval and requires the delivery of Category 4 affordable housing credits for 60% of the additional employees generated by the development. At the time of the final HPC review, this equated to 8.14 FTEs. The employee generation summary to the right is from the final HPC and GMQS application. Exhibit 1 Page 2 Slight adjustments to the 232 project have resulted in a smaller addition of net leasable area and a corresponding lower mitigation requirement. Permit No. 0132.2018.ACBK represents a total net leasable of 4,818 square feet, comprised of 3,428sf on the main floor and 1,389 sf on the second floor. The chart to the right is from the pending permit set (which may not reflect the most-current given the change bubble). A recalculation of the employee generation results in a net addition of 10.69 FTEs. The 60% mitigation results in a 6.41 FTEs to be mitigated. Proposed Main Floor: (3,428 / 1,000) x 3.6 = 12.34 FTEs Proposed Second Floor: (1,389 / 1,000) x 2.7 = 3.75 FTEs Existing Main Floor Credit: (1,500 / 1,000) x 3.6 = 5.4 FTEs 12.34 + 3.75 - 5.40 = 10.69 FTEs 10.69 x 60% = 6.41 FTEs The permit under review may have a slightly different net leasable total as the Zoning Officer has stated that 6.81 FTEs are due. Confirmation of this figure may be needed. The applicant proposes this FTE mitigation in the form of Category 4 affordable housing units to be constructed on the 834 West Hallam Street property (Poppies). The applicant requests any necessary recalculation of this requirement, due to minor adjustments to the net leasable area during construction, utilize this same calculation methodology. The applicant will provide the completed units at 834 prior to receiving a Certificate of Occupancy for 232. 3) The change is limited to technical or engineering considerations discovered prior to or during actual development that could not reasonably be anticipated during the review process or any other minor change that the Community Development Director finds has no substantial effect on the conditions and representations made during the original project review. Response to 3: This minor change affects only the method of affordable housing mitigation associated with the project and no other aspect. The 232 project is otherwise ready to initiate construction. November 2017 City of Aspen|130 S. Galena St.|(970) 920 5090 CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT LAND USE APPLICATION Project Name and Address:_________________________________________________________________________ Parcel ID # (REQUIRED) _____________________________ APPLICANT: Name: ______________________________________________________________________________________________ Address: _______________________________________________________________________________________________ Phone #: ___________________________ email: __________________________________ REPRESENTIVATIVE: Name: _________________________________________________________________________________________________ Address:________________________________________________________________________________________________ Phone#: _____________________________ email:___________________________________ Description: Existing and Proposed Conditions Review: Administrative or Board Review Have you included the following?FEES DUE: $ ______________ Pre-Application Conference Summary Signed Fee Agreement HOA Compliance form All items listed in checklist on PreApplication Conference Summary Required Land Use Review(s): Growth Management Quota System (GMQS) required fields: Net Leasable square footage _________ Lodge Pillows______ Free Market dwelling units ______ Affordable Housing dwelling units_____ Essential Public Facility square footage ________ 232 East Main GMQS Amendment 2737-073-20-008 232 East Main Street LLC, a Colorado limited liability company 2001 N. Halsted St. #304; Chicago, IL 60614 312.479.2050 mhunt@mdevco.com BendonAdams 300 So. Spring St., #202; Aspen, CO 81611 970.925.2855 Chris@BendonAdams.com Change to affordable housing mitigation requirements for fully entitled commercial building. 4,141 sf already granted na na na na 1,950 x x x x Exhibit 2 Exhibit 3 Exhibit 4 Exhibit 5 Active/51235670.1 730 East Durant Avenue, Second Floor, Aspen, Colorado 81611-1557 Telephone: 970.925.6300 Fax: 970.925.1181 www.shermanhoward.com Curtis B. Sanders Sherman & Howard L.L.C. Direct Dial Number: 970.300.0114 E-mail: csanders@shermanhoward.com February 4, 2020 City of Aspen Community Development Department 130 South Galena Street Aspen, Colorado 81611 Re: 232 East Main Street LLC, a Colorado limited liability company; Certificate of Ownership Dear Sir or Madam: I am an attorney licensed by the State of Colorado to practice law. This letter shall confirm and certify that 232 East Main Street LLC, a Colorado limited liability company is the owner of certain improved real property located at 232 East Main Street, Aspen, Colorado 81611, and legally described as follows (the "Subject Property"): Lots R and S, Block 73, City and Townsite of Aspen, County of Pitkin, State of Colorado. The Subject Property is subject to the following matters of record: 1. Restrictions as set forth in Deed recorded November 30, 1888 in Book 59 at Page 521. 2. Ordinance No. 60, Series of 1976, designating the Subject Property as within an Historic District recorded December 9, 1976 in Book 321 at Page 51. 3. Terms, conditions, provisions and obligations as set forth in the Deed of Trust, Assignment of Leases and Rents and Security Agreement dated as of November 6, 2019 and given by 232 East Main Street LLC in favor of LOANCORE CAPITAL CREDIT LLC recorded November 7, 2019 as Reception No. 660249, Pitkin County, Colorado. 4. Terms, conditions, provisions and obligations as set forth in the Assignment of Leases and Rents dated as of November 6, 2019 and given by 232 East Main Street LLC in favor of Exhibit 6 2 Active/51235670.1 LOANCORE CAPITAL CREDIT LLC recorded November 7, 2019 as Reception No. 660250, Pitkin County, Colorado. 5. Terms, conditions, provisions and obligations as set forth in the UCC Financing Statement given by 232 East Main Street LLC in favor of LOANCORE CAPITAL CREDIT LLC recorded November 7, 2019 as Reception No. 660251, Pitkin County, Colorado. 6. City of Aspen Historic Preservation Commission Resolution #22 (Series of 2016) recorded August 4, 2016 as Reception No. 631178. 7. City of Aspen Historic Preservation Commission Resolution #3 (Series of 2017) recorded April 14, 2017 as Reception No. 637583. 8. Memorandum of Lease dated November 20, 2018 between 232 East Main Street LLC as landlord and JPMorgan Chase Bank, N.A. as tenant recorded November 26, 2018 as Reception No. 652151. 9. Subordination, Non-Disturbance and Attornment Agreement dated November 6, 2019 among 232 East Main Street LLC, JPMorgan Chase Bank, N.A., and LOANCORE CAPITAL CREDIT REIT LLC recorded November 7, 2019 as Reception No. 660252. This letter shall further confirm that as the owner of the Subject Property, 232 East Main Street LLC has the right and authority to file and pursue land use applications, variance requests, and other requests with the City of Aspen with respect to the Subject Property, and that Mark Hunt, as the President of 232 East Main Street Aspen Manager, Inc., a Colorado corporation, as Manager of 232 East Main Street LLC, is authorized to act on behalf of 232 East Main Street LLC with respect to the Subject Property. Sincerely, Curtis B. Sanders PRE-APPLICATION CONFERENCE SUMMARY PLANNER: Ben Anderson, 970.429.2765 DATE: February 3, 2020 PROJECT: 232 E. Main / 834 W. Hallam REPRESENTATIVE: Chris Bendon; BendonAdams TYPE OF APPLICATION: Administrative Amendment to a GMQS Development Order – 232 E. Main Administrative Amendment to a GMQS Development Order and Amendment to Affordable Housing Certificates – 834 W. Hallam DESCRIPTION: This PreApp is a description of a process that will result in two, distinct land use applications and reviews – but that are directly related in the outcome and should be reviewed simultaneously. 232 E. Main received Final HPC approval in Resolution No. 3, Series of 2017 for the redevelopment of the commercial structure on the property. Section 2 of the resolution required the provision of required mitigation in the form of Affordable Housing Credits (Category 4) at the time of building permit issuance. Per Zoning review of the subsequently submitted building permit – the project will require the extinguishment of 6.86 FTE, Cat. 4 Housing Credits. 834 W. Hallam received Final HPC approval in Resolution No. 14, Series of 2017 for the redevelopment of the former Poppies Restaurant, a designated property. The project would create affordable housing units that would generate 18.75 FTE, Cat. 4 Housing Credits. These two projects are currently under related ownership – and the developer would like to tie the two projects together – in allowing a portion of the units developed at 834 W. Hallam to be used to satisfy the mitigation requirements at 232 E. Main. Staff has determined that this proposal will require amendments to the approvals for both of the projects. In the case of 232 E. Main, the amendment will state that the mitigation for the net leasable created by the project will be provided with off-site units completed as part of the project at 834 W. Hallam. The Certificate of Occupancy for the 232 E. Main project will be conditioned on the issuance of a Certificate of Occupancy for the AH units created at 834 W Hallam project. This amendment, if approved, will be administrative and in the form of a Notice of Approval. The applicant should be aware that once this amendment is established, under no circumstances will the CO for 232 E. Main be considered until the AH units at 834 W. Hallam have been issued a CO. In the case of 834 W. Hallam, the amendment will identify the relationship to the project at 232 E. Main. It will also specify the provision of 6.86 FTE (or the final number established at project completion), Cat. 4 mitigation to the 232 project and will specify that the balance of 11.89 FTE. Cat. 4 (or the final number remaining after the provision of the 232 mitigation – will be issued as affordable housing credits following the CO of the 834 project. This amendment, if approved, will be administrative an in the form of a Notice of Approval. Due to the assumed time demands of this request, it is recommended that the applicant provide proposed language for the two notices of approval as part of the application submittal. This submission is not required but may facilitate a more efficient review. Below is a link to the Land Use Application Form for your convenience: https://www.cityofaspen.com/191/Municipal-Code The City of Aspen Land Use Code can be accessed at: https://www.cityofaspen.com/DocumentCenter/View/1835/Land-Use-Application-Packet-2017 Land Use Code Section(s) 26.304 Common development review procedures 26.470.150 Insubstantial Amendment to a Growth Management Development Order (Both 232 and 834) 26.540.130 Amendment to a project that creates affordable housing certificates (834 only) Review by: Staff for application completeness Community Development Director for review Public Hearing: No. Planning Fees: 232 E. Main Street $1300 planning deposit for up to 4 billable hours. Additional/lesser hours billed/refunded at $325 per hour. 834 E. Hallam Ave. $1300 planning deposit for up to 4 billable hours. Additional/lesser hours billed/refunded at $325 per hour. Referral Fees: APCHA on each – Flat Fee $650 each Total Deposit: $1,950 for each submitted application To apply, submit the following items in PDF/digital format – for each of the applications  Completed Land Use Application and signed fee agreement.  Pre-application Conference Summary (this document).  Street address and legal description of the parcels on which development is proposed to occur, consisting of a current (no older than 6 months) certificate from a title insurance company, an ownership and encumbrance report, or attorney licensed to practice in the State of Colorado, listing the names of all owners of the property, and all mortgages, judgments, liens, easements, contracts and agreements affecting the parcel, and demonstrating the owner’s right to apply for the Development Application.  Applicant’s name, address and telephone number in a letter signed by the applicant that states the name, address and telephone number of the representative authorized to act on behalf of the applicant.  HOA Compliance form (attached to the Land Use Application).  Narrative of the project proposal – that includes a description that relates the project timelines of the 232 and 834 projects.  Written responses to the criteria in the two sections identified above (26.470.150 and 26.540.130) that would allow these amendments to be reviewed administratively.  Recommended – proposed language for the amendment as described in the Notice of Approval. Refer to the language in the description section above for guidance on the content of this proposed language. Once the copy is deemed complete by staff, the following items will then need to be submitted:  Total deposit for review of each application. Disclaimer: The foregoing summary is advisory in nature only and is not binding on the City. The summary is based on current zoning, which is subject to change in the future, and upon factual representations that may or may not be accurate. The summary does not create a legal or vested right. Exhibit 8 Vicinity Map Exhibit 9 Exhibit 10 2. All dimensional calculations, and the calculation for any form of mitigation, will be verified during building permit review. 3. The development approvals granted herein shall constitute a site -specific development plan vested for a period of three (3) years from the date of issuance of a development order. However, any failure to abide by any of the terms and conditions attendant to this approval shall result in the forfeiture of said vested property rights. Unless otherwise exempted or extended, failure to properly record all plats and agreements required to be recorded, as specified herein, within 180 days of the effective date of the development order shall also result in the forfeiture of said vested property rights and shall render the development order void within the meaning of Section 26.104.050 (Void permits). Zoning that is not part of the approved site -specific development plan shall not result in the creation of a vested property right. No later than fourteen (14) days following final approval of all requisite reviews necessary to obtain a development order as set forth in this Ordinance, the City Clerk shall cause to be published in a newspaper of general circulation within the jurisdictional boundaries of the City of Aspen, a notice advising the general public of the approval of a site specific development plan and creation of a vested property right pursuant to this Title. Such notice shall be substantially in the following form: Notice is hereby given to the general public of the approval of a site specific development . plan, and the creation of a vested property right, valid for a period of three (3) years, pursuant to the Land Use Code of the City of Aspen and Title 24, Article 68, Colorado Revised Statutes, pertaining to the following described property: 232 E. Main Street. Nothing in this approval shall exempt the development order from subsequent reviews and approvals required by this approval of the general rules, regulations and ordinances or the City of Aspen provided that such reviews and approvals are not inconsistent with this approval. The approval granted hereby shall be subject to all rights of referendum and judicial review; the period of time permitted by law for the exercise of such rights shall not begin to run until the date of publication of the notice of final development approval as required under Section 26.304.070(A). The rights of referendum shall be limited as set forth in the Colorado Constitution and the Aspen Home Rule Charter. Section 2: Pursuant to the procedures and standards set forth in Title 26 of the Aspen Municipal Code, Growth Management approval is granted for the construction of approximately 4,141 square feet of new net leasable space, with the condition that 60% of the FTEs generated by the new net leasable area shall be in the form of Category 4 credits. Section 3: • All material representations and commitments made by the Applicant pursuant to the development proposal approvals as herein awarded, whether in public hearing or documentation presented Historic Preservation Commission Resolution #3, Series 2017 Page 2 of 3 • before the Community Development Department and the Historic Preservation Commission are hereby incorporated in such plan development approvals and the same shall be complied with as if fully set forth herein, unless amended by other specific conditions or an authorized authority. • Section 4: This Resolution shall not affect any existing litigation and shall not operate as an abatement of any action or proceeding now pending under or by virtue of the ordinances repealed or amended as herein provided, and the same shall be conducted and concluded under such prior ordinances. Section 5: If any section, subsection, sentence, clause, phrase, or portion of this Resolution is for any reason held invalid or unconstitutional in a court of competent jurisdiction, such portion shall be deemed a sepaiate, distinct and independent provision and shall not affect the validity of the remaining portions thereof. FINALLY, adopted, passed and approved this 8`h day of February, 2017. as to content: Jeffrev\Ha?fcrty. Chair form: Assistant City Attorney A st: n v Nicole Henning, Deputy City Ierk Historic Preservation Commission Resolution #3. Series 2017 Page 3 of 3 UP 3 A-310 10 0 ' - 0 " 10 0 ' - 0 " 23'-10 7/8"28'-7 1/2"7'-2 5/8" 85 ' - 0 " 10 ' - 0 " 59'-9" TENANT SPACE 'A' 100 1 A-300 2 A-300 1 A-301 TENANT SPACE 'B' 101 3 A-400 1 A-310 2 A-310 5' - 3 " 2' - 7 3 / 4 " R. O . 10 ' - 7 3 / 4 " 2' - 7 5 / 8 " R. O . 10 ' - 7 3 / 4 " 2' - 7 3 / 4 " R. O . 10 ' - 7 3 / 4 " 2' - 7 5 / 8 " R. O . 10 ' - 7 3 / 4 " 2' - 7 1 / 2 " 1' - 1 0 1 / 2 " 7' - 1 1 7 / 8 " M. O . 11 ' - 4 " 12 ' - 9 3 / 8 " 5' - 0 1 / 8 " TRASH AREA (300 SF) 103 AIR CURTAIN BY TENANT AIR CURTAIN OR VESTIBULE BY TENANT 13 ' - 7 1 / 8 " TRANSFORMER FOLDING DOOR FOLDING DOOR FOLDING DOOR MECH. RM. 102 ELEV. -2'-0" 24 ' - 5 1 / 4 " 9 5 / 8 " 30 ' - 2 3 / 4 " 7 1 / 4 " 4 7 / 8 " 7' - 8 " 5'-0" A-410 1 A-411 1 A-412 1 1 A-311 2 A-311 1 A-600 A-500 1 A-400 1 24'-4"9'-6 3/4"8'-4"9'-2 1/4" 10'-8 1/4"10'-11 1/4"10'-11 1/4"10'-6"10'-8 1/2" 5'-6 1/4"4'-11 3/4" 5' - 0 " 6' - 7 " 11 ' - 1 1 3 / 4 " 12 ' - 6 3 / 4 " 4' - 0 1 / 8 " 13 ' - 5 " 13 ' - 3 " 13 ' - 5 " 3' - 1 0 3 / 8 " 4' - 1 0 1 / 4 " 4' - 9 " 1' - 0 5 / 8 " 8 7/8" 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 D.S. D.S. D.S. FOUNDATION DRYWELL STORM DRYWELL C-1 L B-3 A C E1s Es 4' - 8 5 / 8 " D.S. D.S. AIR CURTAIN, BY TENANT 3" 10'-10 1/4" D.S. 23'-7 7/8" 22'-10 5/8" 7 1/4" 4'-8 3/8"21'-8 1/2" 1'-10" HSS8x8x1/2 HSS8x8x1/2 HSS5x5x1/4 HSS8x8x1/2 ACCESS PANEL ACCESS PANEL 3 A-311 0" 0" 54'-6" *ADA PUSH BUTTON *ADA PUSH BUTTON * ADA PUSH BUTTON GAS METERS 5 A-501 6 A-501 A1 B 3 F A4 3 3 3 A2 3 B1 3 C8 3 D 3 D 3 D.S. 3 DRAIN TILE, TYP. DRAIN TILE, TYP.3 3 14'-0" M.O. 9'-0" 7 7/8" BOLLARD, TYP. 1'- 1 1 / 4 " 5 1 / 8 " 10 1/8" 1'-4" M.O. 3'-4"18'-0 3/4" M.O. 3'-4" ACCESS PANEL B2 3 D24 R H 5 -2'-0" 5 E1s 6 -2'-0" CORRIDOR 104 T E1 STAIR 105 U Es 6 6 1'-6"R.O. 3'-2" 1/2" 8'-2 1/8" 4'- 3 1 / 8 " F1 F1 6 6 D2 5'-6" F1 8'- 8 5 / 8 " 5'-0 1/2" 5x5x1/4 -1'-7 1/8" TWO-WAY COMMUNICATION SYSTEM3 1. PROVIDE F.T. WOOD BLOCKING AT ALL WALL MOUNTED FIXTURES, GRAB BARS, ACCESSORIES AND MILLWORK. 2. FIRE RATED HORIZONTAL AND VERTICAL ASSEMBLIES ARE TO BE CONTINUOUS AND UNINTERRUPTED. 3. ALL EXPOSED STEEL ON THE EXTERIOR OF THE BUILDING IS TO BE PRIMED AND PAINTED. 4. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL DESIGN CONCEPT. THESE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL COMPLETION OF THE PROJECT. 5. THE CONTRACTOR OR SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS AND CONDITIONS PRIOR TO THE EXECUTION OF ANY WORK AND SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. 6. SUBCONTRACTOR SHALL VERIFY ALL PARTITION LAYOUTS WITH THE ARCHITECT BEFORE PROCEEDING WITH FRAMING. 7. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES IN ORDER TO AVOID INTERFERENCES, PRESERVE MAXIMUM HEAD ROOM AND AVOID OMISSIONS. 8. ALL DOORS USED IN CONNECTION WITH EXITS SHALL BE READILY OPENABLE WITHOUT THE USE OF A KEY FROM THE SIDE FROM WHICH EGRESS IS MADE. 9. DIMENSIONS MARKED 'HOLD' ARE CRITICAL AND MUST BE ADHERED TO. WALL DIMENSIONS ARE FACE TO FACE OF FINISHED WALL. 10. DIMENSIONS, TARGETS, ETC. THAT ARE TYPICAL FOR MANY AREAS ARE NOTED ONLY ONCE. 11. PROVIDE PRIME COAT ONLY BEHIND AREAS TO BE COVERED WITH MILLWORK, FILE CABINETS, WALL COVERINGS, PANELS, ETC., TYPICAL UNLESS NOTED OTHERWISE. 12. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT HIGH MOISTURE AND/OR WET AREAS (IE., SINKS, TOILETS, SHOWERS, ETC.) 13. PROVIDE TILE BACKER CEMENT BOARD AS REQUIRED AT ALL TILE/STONE WET AREA APPLICATION (IE.,SINKS, TOILETS, SHOWERS, ETC.) 14. INTERSECTION BETWEEN UNLIKE MATERIALS ARE TO BE SEALED WITH PAINTABLE CAULK U.N.O. 15. UPON INSTALLATION OF DOOR FRAMES, FILL AND/OR CAULK ANY/ALL GAPS, HOLES, VOIDS, ETC. BETWEEN DOOR FRAME AND WALL SYSTEM, TYPICAL. CAULK TO BE PAINTABLE. 16. THRESHOLDS BE CONTINUOUS FROM JAMB TO JAMB AND/OR WALL TO WALL. 17. THRESHOLD END CONDITIONS TO BE TIGHTLY CUT/SCRIBED TO MATCH SHAPE/PROFILE OF JAMB/WALL WITHOUT ANY GAPS, HOLES, VOIDS, ETC. 18. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL NOT BE CHANGED WITHOUT THE ARCHITECT'S WRITTEN APPROVAL. 19. ALL INTERIOR FINISHES TO COMPLY WITH IBC 2015 TABLE 803.11. 22. EXPOSED CONCRETE WORK IN PUBLIC AREA TO RECEIVE CLEAR CONCRETE SEALER IF NOT INTENDED TO BE PAINTED. 23. G.C. TO CONFIRM/ COORDINATE ELEVATOR SHAFTS/ ROUGH OPENINGS BEFORE COMENCING CONSTRUCTION. 25. ELEV. 0'-0" = 7903.20' 26. WALLS SURROUNDING TRASH AND MECHANICAL ROOMS ARE TO BE SMOKE SEALED PARTITIONS. ANY PENETRATIONS THROUGH THESE WALL ARE TO BE SEALED FROM THE PASSAGE OF SMOKE. 27. STEEL STRUCTURE SUPPORTING STAIR STRINGERS TO RECEIVE 1 HR. GYPSUM FIREPROOFING WRAP. GENERAL NOTES: 6 Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. 3/16" = 1’−0" 12 / 1 9 / 2 0 1 9 1 0 : 0 9 : 3 7 A M A−100 2016−005 12.6.19 PROPOSED MAIN FLOOR PLAN CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . A S P E N , C O NO. DATE BY REVISION 1 09.25.18 MODIF. PERMIT SET 2 11.28.18 MODIF. ISSUED FOR BID 3 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS #1 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #2 5 11.12.19 MODIF. PERMIT DOCUMENT REVISION #3 6 12.18.19 MODIF. PERMIT DOCUMENT REVISION #4 3 3 3 3 DN 1,380 2,0001,380 2,000 3 A-310 OPEN TO BELOW OUTDOOR TERRACE 1 A-300 2 A-300 1 A-301 3 A-400 1 A-310 2 A-310 MECH. EQUIP., TYP. SECOND FLOOR TENANT SPACE- 'B' 200 19 ' - 0 1 / 8 " 13 ' - 6 " 19 ' - 6 3 / 4 " 5' - 7 7 / 8 " 26'-2 1/4" A-413 1 1 A-311 2 A-311 A-400 2 24'-4"9'-6 3/4"8'-4"9'-2 1/4" 6' - 7 " 11 ' - 1 1 3 / 4 " 12 ' - 6 3 / 4 " 4' - 0 1 / 8 " 13 ' - 5 " 13 ' - 3 " 13 ' - 5 " 3' - 1 0 3 / 8 " 4' - 1 0 1 / 4 " 4' - 9 " 1' - 0 5 / 8 " 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 MECHANICAL SCREENING, TYP. E3 D.S.D.S. D 19 ' - 5 1 / 8 " R.O. 13 ' - 6 " 24 ' - 2 1 / 2 " ELEV. D.S. 6 1 / 2 " 1' - 1 0 1 / 2 " 10 3 / 4 " 1' - 1 0 1 / 2 " 4'-10 3/4" 3 A-311 10'-8 1/4"10'-11 1/4"10'-11 1/4"10'-6"10'-8 1/2" 5'-6 1/4"4'-11 3/4" 8 7/8" 3" 54'-6" 6' - 2 1 / 2 " 11 ' - 4 " HSS8x8x1/2 HSS8x8x1/2 A-510 4 5 A-510 1 A-504 C6 3 C6 3 C6 3 C8 3 A1 B A4 B2 3 3 3 3 D 3 3 3 D.S. AND SPLASH BLOCK 3 E2 ACCESS PANEL 3 D.S. 3 1 1/2" MIN. THICK INSULATION AT ROOF DRAINS 1/4'' : 1'-0'' 1/4'' : 1'-0'' 7'' MAX. THICK INSULATION 3 3 3 3 1/4'' : 1'-0'' 3 ROOF OVERHANG ABOVE 3 K 3 K D.S. D.S. PVC ROOF MEMBRANE ROOF OVERHANG OF CORTINA LODGE 4 4 CLOSET 202 F M N 6'-6 3/4"3'-0"6'-6 3/4" 4'- 9 3 / 4 " M.O. 3' - 4 " 2" ACCESS PANEL ACCESS PANEL 5 5 42'' HIGH GUARDRAIL 42" HIGH GUARDRAIL 42" HIGH GUARDRAIL 3 5 5 5 ACCESS PANEL ACCESS PANEL F F1 F1 E 4'-0" 4'-6 1/8" STAIR 201 F1 6 ELEV. LOBBY 203 TWO-WAY COMMUNICATION SYSTEM 3 1. PROVIDE F.T. WOOD BLOCKING AT ALL WALL MOUNTED FIXTURES, GRAB BARS, ACCESSORIES AND MILLWORK. 2. FIRE RATED HORIZONTAL AND VERTICAL ASSEMBLIES ARE TO BE CONTINUOUS AND UNINTERRUPTED. 3. ALL EXPOSED STEEL ON THE EXTERIOR OF THE BUILDING IS TO BE PRIMED AND PAINTED. 4. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF THE ARCHITECTURAL DESIGN CONCEPT. THESE DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL COMPLETION OF THE PROJECT. 5. THE CONTRACTOR OR SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS AND CONDITIONS PRIOR TO THE EXECUTION OF ANY WORK AND SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. 6. SUBCONTRACTOR SHALL VERIFY ALL PARTITION LAYOUTS WITH THE ARCHITECT BEFORE PROCEEDING WITH FRAMING. 7. ALL WORK SHALL BE COORDINATED WITH ALL OTHER TRADES IN ORDER TO AVOID INTERFERENCES, PRESERVE MAXIMUM HEAD ROOM AND AVOID OMISSIONS. 8. ALL DOORS USED IN CONNECTION WITH EXITS SHALL BE READILY OPENABLE WITHOUT THE USE OF A KEY FROM THE SIDE FROM WHICH EGRESS IS MADE. 9. DIMENSIONS MARKED 'HOLD' ARE CRITICAL AND MUST BE ADHERED TO. WALL DIMENSIONS ARE FACE TO FACE OF FINISHED WALL. 10. DIMENSIONS, TARGETS, ETC. THAT ARE TYPICAL FOR MANY AREAS ARE NOTED ONLY ONCE. 11. PROVIDE PRIME COAT ONLY BEHIND AREAS TO BE COVERED WITH MILLWORK, FILE CABINETS, WALL COVERINGS, PANELS, ETC., TYPICAL UNLESS NOTED OTHERWISE. 12. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT HIGH MOISTURE AND/OR WET AREAS (IE., SINKS, TOILETS, SHOWERS, ETC.) 13. PROVIDE TILE BACKER CEMENT BOARD AS REQUIRED AT ALL TILE/STONE WET AREA APPLICATION (IE.,SINKS, TOILETS, SHOWERS, ETC.) 14. INTERSECTION BETWEEN UNLIKE MATERIALS ARE TO BE SEALED WITH PAINTABLE CAULK U.N.O. 15. UPON INSTALLATION OF DOOR FRAMES, FILL AND/OR CAULK ANY/ALL GAPS, HOLES, VOIDS, ETC. BETWEEN DOOR FRAME AND WALL SYSTEM, TYPICAL. CAULK TO BE PAINTABLE. 16. THRESHOLDS BE CONTINUOUS FROM JAMB TO JAMB AND/OR WALL TO WALL. 17. THRESHOLD END CONDITIONS TO BE TIGHTLY CUT/SCRIBED TO MATCH SHAPE/PROFILE OF JAMB/WALL WITHOUT ANY GAPS, HOLES, VOIDS, ETC. 18. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL NOT BE CHANGED WITHOUT THE ARCHITECT'S WRITTEN APPROVAL. 19. ALL INTERIOR FINISHES TO COMPLY WITH IBC 2015 TABLE 803.11. 22. EXPOSED CONCRETE WORK IN PUBLIC AREA TO RECEIVE CLEAR CONCRETE SEALER IF NOT INTENDED TO BE PAINTED. 23. G.C. TO CONFIRM/ COORDINATE ELEVATOR SHAFTS/ ROUGH OPENINGS BEFORE COMENCING CONSTRUCTION. 25. ELEV. 0'-0" = 7903.20' 26. WALLS SURROUNDING TRASH AND MECHANICAL ROOMS ARE TO BE SMOKE SEALED PARTITIONS. ANY PENETRATIONS THROUGH THESE WALL ARE TO BE SEALED FROM THE PASSAGE OF SMOKE. 27. STEEL STRUCTURE SUPPORTING STAIR STRINGERS TO RECEIVE 1 HR. GYPSUM FIREPROOFING WRAP. GENERAL NOTES: 6 T/PARAPET 14'-8" 2ND LEVEL 12'-0" 4" 3'- 6 " EQ.EQ.EQ.EQ. EQ . EQ . Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. As indicated 12 / 1 9 / 2 0 1 9 1 0 : 0 9 : 3 9 A M A−101 2016−005 12.6.19 PROPOSED 2ND FLOOR PLAN CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . A S P E N , C O NO. DATE BY REVISION 1 09.25.18 MODIF. PERMIT SET 2 11.28.18 MODIF. ISSUED FOR BID 3 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS #1 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #2 5 11.12.19 MODIF. PERMIT DOCUMENT REVISION #3 6 12.18.19 MODIF. PERMIT DOCUMENT REVISION #4 3 3 3 1/2" = 1'-0"2 GUARDRAIL ELEVATION 6 Exhibit 11 1,380 2,0001,380 2,000 FIBER-REINFORCED CEMENT PANELS WITH OPEN JOINTS OVER ROOF AT (9/12) SLOPE. 1798 SF SLOPED GLAZING 90 SF CEDAR SHAKE SHINGLES OVER GABLED ROOF, ROOF PROPOSED SNOW MELT SYSTEM TO ALLEVIATE SNOW SHEDDING BOTH IN THE ROW AND ON ANY ADJACENT LOTS SNOW CLEAT 3 A-310 1 A-300 2 A-300 1 A-301 3 A-400 9" / 1'-0"9" / 1'-0"9" / 1'-0" GUTTER 9" / 1'-0"9" / 1'-0" 9" / 1 ' - 0 " 9" / 1 ' - 0 " AWNING, TYP. 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 9" / 1'-0" INTERNAL GUTTERS, TYP. INTERNAL GUTTER, TYP. INTERNAL D.S., TYP. 3" V.T.R. 3" V.T.R. 1" / 1 ' -0" MECHANICAL EQUIPMENT SETBACK 15 ' - 0 " LINE OF BUILDING BELOW LINE OF BUILDING BELOW MECHANICAL EQUIPMENT SETBACK 15'-0" MECHANICAL EQUIPMENT SETBACK 15'-0" PROPOSED SATELLITE LOCATION D.S. D.S. ROOF ACCESS 24'-4"9'-6 3/4"8'-4"9'-2 1/4" 12 ' - 6 3 / 4 " 4' - 0 1 / 8 " 13 ' - 5 " 13 ' - 3 " 13 ' - 5 " 3' - 1 0 3 / 8 " 4' - 1 0 1 / 4 " 4' - 9 " 10'-8 1/4"10'-11 1/4"10'-11 1/4"10'-6"10'-8 1/2" 5'-6 1/4"4'-11 3/4" 8 7/8" 3" 54'-6" 6' - 7 " 11 ' - 1 1 3 / 4 " PROPOSED SNOW MELT SYSTEM TO ALLEVIATE SNOW SHEDDING BOTH IN THE ROW AND ON ANY ADJACENT LOTS PROPOSED SNOW MELT SYSTEM TO ALLEVIATE SNOW SHEDDING BOTH IN THE ROW AND ON ANY ADJACENT LOTS PROPOSED SNOW MELT SYSTEM TO ALLEVIATE SNOW SHEDDING BOTH IN THE ROW AND ON ANY ADJACENT LOTS 88 ' - 8 3 / 8 " 42'' HIGH GUARDRAIL3 1 A-504 3 3 ROOF OVERHANG OF CORTINA LODGE INTEGRAL FORMED COPPER GUTTER AND D.S., TYP. INTEGRAL FORMED COPPER GUTTER AND D.S., TYP. INTEGRAL FORMED COPPER GUTTER AND D.S., TYP. 4 4 4 42" HIGH GUARDRAIL 42" HIGH GUARDRAIL 5 5 Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. 3/16" = 1’−0" 12 / 1 9 / 2 0 1 9 1 0 : 0 9 : 4 1 A M A−131 2016−005 12.6.19 ROOF PLAN CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . A S P E N , C O NO. DATE BY REVISION 1 09.25.18 MODIF. PERMIT SET 2 11.28.18 MODIF. ISSUED FOR BID 3 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS #1 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #2 5 11.12.19 MODIF. PERMIT DOCUMENT REVISION #3 6 12.18.19 MODIF. PERMIT DOCUMENT REVISION #4 ZONING: (MU) MIXED USE NET LOT AREA: 5,981 SF (59'-9" X 100'-0") ZONING ALLOWANCE (0.75:1) 4,482 SF (0.75 X 5,981SF) (1:1) 5,981 BY SPECIAL REVIEW (1 X 5,981 SF) PROPOSED F.A.R. 5811SF / 5981SF = (0.97:1) ZONING INFO AND CALCS: ELEV. 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 TENANT SPACE 'A' TENANT SPACE 'B' MECH. RM. DECK TRASH AREA (300 SF) OUTDOOR TERRACE FLOOR AREA RATIO (F.A.R.) LEGEND AREA TOWARD F.A.R. OPEN TO BELOW ELEV. 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 SECOND FLOOR TENANT SPACE-'B' 3 3/16" = 1'-0"1 MAIN FLOOR - PROPOSED PLAN 3/16" = 1'-0"2 2ND LEVEL - PROPOSED PLAN FLOOR AREA SUMMARY - AREA TOWARD F.A.R. NAME AREA MAIN FLOOR RETAIL SPACE 'A'2981 SF RETAIL SPACE 'B'634 SF MECH. RM.356 SF TRASH AREA 353 SF RETAIL 'B' SECOND FLOOR 1488 SF 5812 SF Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. As indicated 12 / 1 9 / 2 0 1 9 1 0 : 1 0 : 4 9 A M Z−001 2016−005 12.6.19 FAR CALCULATIONS CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . A S P E N , C O NO. DATE BY REVISION 1 09.25.18 MODIF. PERMIT SET 2 11.28.18 MODIF. ISSUED FOR BID 3 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS #1 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #2 5 11.12.19 MODIF. PERMIT DOCUMENT REVISION #3 6 12.18.19 MODIF. PERMIT DOCUMENT REVISION #4 4 4 4 1487 5811 1,380 2,0001,380 2,000 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 AREA TOWARD F.A.R. NO F.A.R. THIS LEVEL ZONING: (MU) MIXED USE NET LOT AREA: 5,981 SF (59'-9" X 100'-0") ZONING ALLOWANCE (0.75:1) 4,482 SF (0.75 X 5,981SF) (1:1) 5,981 BY SPECIAL REVIEW (1 X 5,981 SF) PROPOSED F.A.R. 5811SF / 5981SF = (0.97:1) ZONING INFO AND CALCS: FLOOR AREA RATIO (F.A.R.) LEGEND Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. As indicated 12 / 1 9 / 2 0 1 9 1 0 : 1 0 : 5 1 A M Z−002 2016−005 12.6.19 FAR CALCULATIONS CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . A S P E N , C O 3/16" = 1'-0"1 PROPOSED ROOF PLAN FLOOR AREA SUMMARY - AREA TOWARD F.A.R. NAME AREA MAIN FLOOR RETAIL SPACE 'A'2981 SF RETAIL SPACE 'B'634 SF MECH. RM.356 SF TRASH AREA 353 SF RETAIL 'B' SECOND FLOOR 1488 SF 5812 SF NO. DATE BY REVISION 1 09.25.18 MODIF. PERMIT SET 2 11.28.18 MODIF. ISSUED FOR BID 3 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS #1 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #2 5 11.12.19 MODIF. PERMIT DOCUMENT REVISION #3 6 12.18.19 MODIF. PERMIT DOCUMENT REVISION #4 1487 5811 2843 SF MAIN FLOOR RETAIL SPACE 'A' NET LEASABLE AREA LEGEND TOWARD NET LEASABLE EXEMPT FROM NET LEASABLE 327 SF DECK 312 SF TRASH ROOM 585 SF MAIN FLOOR TENANT SPACE 'B' LOBBY 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 336 SF MECH. RM. OUTDOOR TERRACE OPEN TO BELOW LOW HEAD CLEARANCE 1389 SF SECOND FLOOR TENANT SPACE 'B' 57 SF ELEV. 73 SF STAIRS 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 TOWARD NET LEASABLE NAME AREA MAIN FLOOR RETAIL SPACE 'A' 2843 SF MAIN FLOOR TENANT SPACE 'B' LOBBY 585 SF SECOND FLOOR TENANT SPACE 'B' 1389 SF TOTAL AREA 4818 SF 3/16" = 1'-0"1 MAIN FLOOR - NET LEASABLE AREA 3/16" = 1'-0"2 2ND LEVEL - NET LEASABLE AREA EXEMPT FROM NET LEASABLE NAME AREA MECH. RM.336 SF DECK 327 SF TRASH ROOM 312 SF STAIRS 73 SF ELEV.57 SF TOTAL AREA 1103 SF Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. 3/16" = 1’−0" 12 / 1 9 / 2 0 1 9 1 0 : 1 0 : 5 3 A M Z−003 2016−005 12.6.19 NET LEASABLE CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . A S P E N , C O NO. DATE BY REVISION 1 09.25.18 MODIF. PERMIT SET 2 11.28.18 MODIF. ISSUED FOR BID 3 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS #1 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #2 5 11.12.19 MODIF. PERMIT DOCUMENT REVISION #3 6 12.18.19 MODIF. PERMIT DOCUMENT REVISION #4 4 4 1 2 3 4 5 6 7 8 8.5 9 10 A B C D E F G C.2 C.4 E.8 F.8 TOWARD NET LEASABLE EXEMPT FROM NET LEASABLE NO NET LEASABLE AREA THIS LEVEL Scale PROJECT NUMBER DATE DRAWN BY CHECKED BY modif. modif. 3/16" = 1’−0" 12 / 1 9 / 2 0 1 9 1 0 : 1 0 : 5 5 A M Z−004 2016−005 12.6.19 NET LEASABLE CO M M E R C I A L DE V E L O P M E N T 23 2 E . M A I N S T . A S P E N , C O 3/16" = 1'-0"1 ROOF - NET LEASABLE AREA TOWARD NET LEASABLE NAME AREA MAIN FLOOR RETAIL SPACE 'A' 2843 SF MAIN FLOOR TENANT SPACE 'B' LOBBY 585 SF SECOND FLOOR TENANT SPACE 'B' 1389 SF TOTAL AREA 4818 SF EXEMPT FROM NET LEASABLE NAME AREA MECH. RM.336 SF DECK 327 SF TRASH ROOM 312 SF STAIRS 73 SF ELEV.57 SF TOTAL AREA 1103 SF NET LEASABLE AREA LEGEND NO. DATE BY REVISION 1 09.25.18 MODIF. PERMIT SET 2 11.28.18 MODIF. ISSUED FOR BID 3 05.24.19 MODIF. PERMIT DOCUMENT REVISIONS #1 4 08.2.19 MODIF. PERMIT DOCUMENT REVISION #2 5 11.12.19 MODIF. PERMIT DOCUMENT REVISION #3 6 12.18.19 MODIF. PERMIT DOCUMENT REVISION #4 NET LEASABLE AREA = 1500SF FUEL PUMPS (NIC IN EXISTING NET LEASABLE AREA) Scal e PR O J E C T NU M B E R DA T E DR A W N B Y CH E C K E D B Y 11 −14 −16 RA HP C F I N A L − D R A F T 1/4" = 1’−0" 11/23/2016 8:15:33 AM EC−1 Pr o j e c t Nu m b e r Is s u e D a t e Au t h o r Ch e c k e r EXISTING FLOOR PLANS 23 2 E . M A I N S T R E E T AS P E N , C O . 1/4" = 1'-0"1 EXISTING FLOOR PLAN NO. DATE BY DESCRIPTION 1 03.02.16 SC ISSUED TO LAND PLANNER Exhibit 12