Loading...
HomeMy WebLinkAboutEXHIBIT-L_121_HPC-CIVIL-ARCH121 W est Bleeker Residence - HPC Conceptual Submission Cover Letter/ Application - 1 Friday Design Survey, Civil & Architectural Related Drawings / Documents Boundaries Unlimited Inc. + 1 Friday Design A-COVER / INDEX : HPC Conceptual Submission Sheet Index - 2021 - "121 West Bleeker" Structural Related Drawings / Documents JJR Structural TBD " 1 2 1 W e s t B l e e k e r " 1 2 1 w e s t b l e e k e r s t r e e t l c i t y o f a s p e n | c o l o r a d o R E S I D E N C E HPC CONCEPTUAL - JANUARY 2021 SURVEY : 121 West Bleeker Site & Topographical Stamped/ Certified Survey - 1' Contour Intervals - Boundaries Unlimited Inc. (1/8" Architectural) C2.0: 121 West Bleeker Conceptual Grading & Drainage Plan (1/8" Architectural) & Vicinity Map, Detail of Block 58 (1:60 Engineering Scale) C2.0: 121 West Bleeker Conceptual Detailing - Grading & Drainage Planning ZN-001 : Preliminary Project Summary & Existing / Proposed Gross Sq Ft & Floor Area Calculation Summaries - 250 SF HPC Bonus Requested ZN-003 : Existing + Proposed Site Coverage Calculations and Graphic Diagrams (1/8" Architectural) ZN-004 : Existing Floor Area Calculations & Graphic Breakdowns : Subgrade & Main Levels (1/8" Architectural) ZN-005 : Existing Floor Area Calculations & Graphic Breakdowns : Upper & Roof Levels (1/8" Architectural) ZN-006 : Proposed Floor Area Calculations & Graphic Breakdowns : Lower / Subgrade Level (1/8" Architectural) - 250 SF Bonus Requested ZN-007 : Proposed Floor Area Calculations & Graphic Breakdowns : Main + Upper Levels (1/8" Architectural) - 250 SF Bonus Requested A2.01 : Existing Main Level Plan & Historical / Non-Historical Graphic Indication ( 1/4" Architectural) A2.02 : Existing Upper Level Plan & Historical / Non-Historical Graphic Indication ( 1/4" Architectural) A2.03 : Existing Roof Plan & Historical / Non-Historical Graphic Indication ( 1/4" Architectural) A2.04 : Proposed Lower Level / Subgrade Plan ( 1/4" Architectural) A2.05 : Proposed Main Level / Ground Floor Plan ( 1/4" Architectural) A2.06 : Proposed Upper Level Floor Plans - Historical (Street Facing) and Proposed New Construction (South Alley) ( 1/4" Architectural) A2.07 : Proposed Roof Plan ( 1/4" Architectural) A3.01 : Existing Elevations & Non - Historical / Areas Proposed for Removal ( 1/4" Architectural) A3.02 : Existing Elevations & Non - Historical / Areas Proposed for Removal ( 1/4" Architectural) A3.03 : Existing Elevations & Non - Historical / Areas Proposed for Removal ( 1/4" Architectural) A3.04 : Proposed Elevations & Preliminary Materials Development ( 1/4" Architectural) A3.05 : Proposed Elevations & Preliminary Materials Development ( 1/4" Architectural) A3.06: Proposed Elevations & Preliminary Materials Development ( 1/4" Architectural) A2.08 : Proposed Conceptual Landscape Plan ( 3/16" Architectural) HPC JANUARY 2021 COVER HPC CONCEPTUAL COVER SHEET + INDEX 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC JANUARY 2021 SURVEY CITY OF ASPEN COMPLIANT SURVEY 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC JANUARY 2021 C-2 HPC CONCEPTUAL GRADING + DRAINAGE PLAN 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC JANUARY 2021 C-3 HPC CONCEPTUAL CIVIL DETAILS 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP Zoning Allowance & Project Summary Proposed Development Single Family Residence :: Historic Remodel + New Addition Parcel ID #2735 - 124 - 39 - 003 Legal Description of Property 121 West Bleeker Street . City & Townsite of Aspen . Block 58 . East 1/2 Lot C, Lot D, and West 1/2 Lot E Zone District Medium Density Residential (R-6) Reference 26.710.040 26.710.040 26.710.040 26.710.040 26.710.040 26.710.040 26.710.040 Setbacks Existing Allowed (Principle)Allowed (Accessory)Proposed (Principle)Proposed (Accessory) Front Rear Combined Front / Rear Side Combined Side Distance Between Building Corner Lot 16 feet 9 inches (Victorian) - North 0 inches South (11-1/2 inches over property) N/A 4-1/4 inches W :: 1 inch E 5-1/4 inches N/A No N/A N/A N/A N/A N/A N/A N/A 10 feet 10 feet HAB / 5 feet GAR N/A 5 feet W :: 5 feet E 10 feet + 1 foot per 300 sq ft GLA 5 feet 15 feet 5 feet N/A 5 feet W :: 5 feet E 30 feet + 1 foot per 200 sq ft GLA 5 feet 10 ft 1 in HAB / 5 ft 3 in GAR 22 feet 0 inches 1 feet 2 ins W (stair) :: 1 ft 2 in E (mech) 2 feet 4 inches N/A ReferenceSupplemental Breakdown Information Existing Proposed Required Net Leasable / Commercial Square Feet Open Space % Site Coverage 37.47% N/A 0 feet N/A 36.70% Not Required For R-6 Single Family Residence No Limitation For lots less than 6,000 square feet in R-6 Not Required For R-6 Single Family Residence 26.710.040 26.710.040 26.710.040 N/A Reference 26.710.040 Site Coverage Exsiting Proposed Gross Lot Area (Square Feet) Area of Building Footprint Site Coverage % (No Limitation on R-6 Lot : 0 - 5,999 Sq Ft) 5,982.3 square feet 2,241.70 square feet 37.47% 5,982.3 square feet 36.70% 26.710.040 26.710.040 ReferenceTransferable Development Right (TDR) Received TDR Certificate Sent TDR Certificate Transferred TDR Certificate No No No Land Value Summary Actual Value Reference Land Improvements Total 5,371,700 1,971,700 3,400,000 Pitkin County Assessor Pitkin County Assessor Pitkin County Assessor TBD 16 feet 9 inches (Victorian - AG) 2,195.24 square feet TBD TBD Floor Area Summary Existing Gross (Sq Ft)Existing Floor Area (Sq Ft)Proposed Gross (Sq Ft)Proposed Floor Area (Sq Ft)Reference ZN-004, ZN-006 ZN-005, ZN-007 Basement Habitable (Lower Subgrade Level)215.47 0.0 360.422,617.40 Main Level Habitable (Ground Floor)1,900.55 1,900.55 Upper Level Habitable (Existing) ZN-004 - ZN-007 Porch/ Stair Access / Patio/ Roof Deck Area Total 3,563.67 Hab / 372.16 Gar 3,327.92 (FA)3,484.87 (FA)5,709.07 Hab / 524.08 Gar Floor Area Allowable For 121 West Bleeker 3,235.04 square foot FA For SFR FA per SFR on 5,982.3 square foot lot 3,235.04 Total Allowable FA For SFR FA per SFR on 5,982.3 square foot lot with 250 SF HPC FA Bonus (Proposed) = 3,485.04 FA 524.08Main Level Garage (Ground Floor)372.16 61.08 149.08 Exterior Storage Area - Mechanical Usage 4.09 N/A N/A0.0 1,600.70 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 1,600.70 1,102.60 - V (FRT) / 340.96 - (ALY)576.0 - V (FRT) / 914.97 - (ALY)527.67 - V (FRT) / 847.0 - (ALY)1,066.80 - V (FRT) / 299.49 - (ALY) 0 FA Countable / 485.26 Allowable0 FA Countable / 485.26 Allowable467.71 (Total) / 130.72 (Exempt)922.01 (Total) / 64.34 (Exempt) HPC JANUARY 2021 ZN-001 ZONING ALLOWANCE + PROJECT NUMERIC BREAKDOWNS 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP EXPOSED SITE NON-ENCLOSED AREAS / CANOPY OVERHEAD LEGEND ENCLOSED STRUCTURE EXISTING SITE COVERAGE CALCULATIONS TOTAL STRUCTURE FOOTPRINT AREA (SQ FT) 2,241.70 (SF) EXISTING SITE COVERAGE DIAGRAM : 1/8" = 1'-0"EXISTING SITE PLAN : 1/8" = 1'-0" GROSS LOT SIZE / NET LOT SIZE (SQ FT) EXISTING SITE COVERAGE (R-6 MAX = 40%)37.47% (ALLOWABLE) PROPOSED SITE COVERAGE CALCULATIONS PROPOSED SITE COVERAGE (R-6 MAX = NOLIMITATION) 2,195.24 (SF)PROPOSED 121 W BLEEKER SITE COVERAGE (SQ FT) GROSS LOT SIZE / NET LOT SIZE (SQ FT) 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K 12 16 CEDAR SHINGLE ROOFING PROPOSED FLASH & WATERPROOF AS NECESSARY RIDGE RIDGE RIDGE RIDGE RI D G E RI D G E RI D G E RI D G E 12 16 12 16 12 16 12 1612 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 CEDAR SHINGLE ROOFING PROPOSED FLASH & WATERPROOF AS NECESSARY MASONRY CHIMNEY CUSTOM JACUZZI & RAISED PLATFORM AREA - 5'-0" x 5'-0" SPA FLAT ROOF STANDARD STONE BALLAST TOPPING PROPOSED SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 NON-PERMEABLE DECK AREA : PROPOSED STONE DECKING SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 ROOF DECK-MASTER U-214 T.O. F.F. Master Deck ELEV - 111'-11 1/2" (V.I.F.) T.O. Plwd. Mst. Deck / Garage ELEV - 111'-5" (V.I.F.) T.O. Plwd. Connector ELEV - 111'-10" (V.I.F.) FLAT ROOF WITH NEW RUBBER DRAINAGE MATT, STONE BALLAST & WATERPROOFING AS NECESSARY. FLASH & WATERPROOF ROOFING CONDITIONS AS REQUIRED. PV - 1 34 PANEL PV ROOF SYSTEM SITUATED @ 45 DEGREES PV - 2 PV - 1 8 PV - 1 9 PV - 2 0 PV - 3 PV - 4 PV - 2 1 PV - 5 PV - 2 2 PV - 2 3 PV - 6 PV - 7 PV - 2 4 PV - 2 5 PV - 8 PV - 9 PV - 2 6 PV - 1 0 PV - 2 7 PV - 2 8 PV - 1 1 PV - 1 2 PV - 2 9 PV - 3 0 PV - 3 1 PV - 1 3 PV - 1 4 PV - 1 5 PV - 3 2 PV - 1 6 PV - 3 3 PV - 3 4 PV - 1 7 NON REFLECTIVE MATTE / PAINT LOCKED METAL ROOFING PROPOSED 12 1 PROPOSED RESTORATION OF (BELIEVED PER HISTORICAL IMAGERY & EXISTING CONDITIONS) ORIGINAL SOUTH FACADE ROOF MASSING + FORM FP CHIMNEY NON REFLECTIVE MATTE / PAINT LOCKED METAL ROOFING PROPOSED 12 12 12 12 FLAT ROOF WITH NEW RUBBER DRAINAGE MATT, STONE BALLAST & WATERPROOFING AS NECESSARY. FLASH & WATERPROOF ROOFING CONDITIONS AS REQUIRED. PROPOSED SITE COVERAGE DIAGRAM : 1/8" = 1'-0"PROPOSED SITE PLAN : 1/8" = 1'-0" PROPOSED BUILDING FOOTPRINT - 2,195.24 sq ft 121 WEST BLEEKER E 1 2 Lot C, Lot D + W 1 2 Lot E - 5,982.3 sq ft SITE COVERAGE 2,195.24 sq ft / 6,000 sq ft = 36.70 % Site Coverage Proposed 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K DN MASTER DECK 211 ROOF DECK 214 12 16 RIDGE RIDGE RIDGE RIDGE RI D G E RI D G E RI D G E RI D G E 12 16 12 16 12 16 12 1612 16 12 16 12 16 12 16 12 4 12 16 12 4 12 16 12 16 12 16 MASONRY CHIMNEY 12 16 12 16 12 16 12 8 12 16 12 16 12 16 12 8 12 8 12 4 12 16 12 16 12 2 12 2 12 2 12 2 RIDGE RIDGE RI D G E RIDGE LIGHT SHADED AREA REPRESENTS NON HISTORICAL MASSING & FEATURES OF RESIDENCE TO BE REMOVED RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EXISTING BUILDING FOOTPRINT - 2,241.70 sq ft 121 WEST BLEEKER E 1 2 Lot C, Lot D + W 1 2 Lot E - 5,982.3 sq ft SITE COVERAGE 2,241.70 sq ft / 6,000 sq ft = 37.47 % Site Coverage Exisitng 5,982.3 (SF) / 5,982.3 (SF) EXISTING 121 W BLEEKER SITE COVERAGE (SQ FT) 2,241.70 (SF)2,195.24 (SF)TOTAL STRUCTURE FOOTPRINT AREA (SQ FT) 36.70% (ALLOWABLE) 5,982.3 (SF) / 5,982.3 (SF) HPC JANUARY 2021 ZN-003 SITE COVERAGE DIAGRAMS & NUMERIC BREAKDOWNS 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP EXISTING BASEMENT/ SUBGRADE FLOOR AREA PLANNING DIAGRAM : 1/8" = 1'-0" FAR (Z-004) EXISTING MAIN LEVEL FLOOR AREA PLANNING DIAGRAM : 1/8" = 1'-0" 215.47 GROSS SQ FT TOTAL SUBGRADE: 0% WALL EXPOSURE MECHANICAL SUBGRADE EXCAVATION 0 SQ FT FA COUNTABLE 10 ' - 1 1 3 4" 10 ' - 1 1 3 4" KEY - SUBGRADE LVL. / EXISTING SUBGRADE WALL DIAGRAMS : 1/8" = 1'-0" 5' - 9 " 16'-2" 92.96 sq ft UNDERSIDE OF JOIST 5' - 9 " 10'-113 4" 63.13 sq ft UNDERSIDE OF JOIST 5' - 9 " 16'-2" 92.96 sq ft UNDERSIDE OF JOIST 5' - 9 " 10'-113 4" 63.13 sq ft UNDERSIDE OF JOIST HABITABLE GARAGE PORCH/ DECK EXTERIOR STORAGE LEGEND EXISTING MAIN / GROUND FLOOR AREA CALCULATIONS - 121 EXISTING FLOOR AREA CALCULATIONS EXISTING SUBGRADE / LOWER LVL. WALL AREA CALCULATIONS - 121 Floor Area Summary Existing Gross (Sq Ft)Existing Floor Area (Sq Ft)Proposed Gross (Sq Ft)Proposed Floor Area (Sq Ft)Reference ZN-004, ZN-006 ZN-005, ZN-007 Basement Habitable (Lower Subgrade Level)215.47 0.0 360.422,617.40 Main Level Habitable (Ground Floor)1,900.55 1,900.55 Upper Level Habitable (Existing) ZN-004 - ZN-007 Porch/ Stair Access / Patio/ Roof Deck Area Total 3,563.67 Hab / 372.16 Gar 3,327.92 (FA)3,484.87 (FA)5,709.07 Hab / 524.08 Gar Floor Area Allowable For 121 West Bleeker 3,235.04 square foot FA For SFR FA per SFR on 5,982.3 square foot lot 3,235.04 Total Allowable FA For SFR FA per SFR on 5,982.3 square foot lot with 250 SF HPC FA Bonus (Proposed) = 3.485.04 FA 524.08Main Level Garage (Ground Floor)372.16 61.08 149.08 Exterior Storage Area - Mechanical Usage 4.09 N/A N/A0.0 372.16 (GROSS) 1900.55 (FA) 4.09 (GROSS) 61.08 (FA) 294.08 (GROSS) 4.09 SF Exterior Storage (15% of 3235.04) = 485.26 allow 1900.55 (GROSS) 1,600.70 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 1,600.70 1,102.60 - V (FRT) / 340.96 - (ALY)576.0 - V (FRT) / 914.97 - (ALY)527.67 - V (FRT) / 847.0 - (ALY)1,066.80 - V (FRT) / 299.49 - (ALY) 0 FA Countable / 485.26 Allowable0 FA Countable / 485.26 Allowable467.71 (Total) / 130.72 (Exempt) 1,961.63 (FA)TOTAL EXISTING GROUND FLOOR AREA (SQ FT) TOTAL EXISTING FLOOR AREA CALCULATIONS - 121 BASEMENT FLOOR AREA (SQ FT) GROUND FLOOR AREA (SQ FT) 2ND FLOOR AREA (SQ FT) PORCH/ DECK AREA TOTAL (SQ FT) TOTAL EXISTING FLOOR AREA (SQ FT) GARAGE FLOOR AREA (SQ FT) 215.47 / 0.0 (FA) 1,900.55 / 1,900.55 (FA) 598.43 GROSS / 0 (FA) 3,327.92 (FA)(3,327.92 FA > 3,235.04 FA) 372.16 / 61.08 (FA) (3,235.04 x .15%) = 485.26 all 1,443.56 / 1,366.29 (FA) 922.01 (Total) / 64.34 (Exempt) 372.16 SF GARAGE 1st 250 SF EXEMPT 2nd 250 SF @ 1/2 122.16 / 2 = 61.08 SF FA COUNTABLE 1900.55 GROSS SQUARE FEET AREA 1900.55 SF FA COUNTABLEL-A :M-A : M-F M-B : 4.09 SF EXTERIOR STORAGE UP TO 36 SF EXEMPT THEREFORE, 0 SF FA COUNTABLE M-C : 15.97 SF EXT. ENTRY (PRIMARY) STEPS STREET FACING / HISTORIC THEREFORE, 0 SF FA COUNTABLE M-D : 114.75 SF EXT. ENTRY (SECONDARY) STEPS + PORCH STREET FACING / (NON-HISTORIC) THEREFORE, 0 SF FA COUNTABLE M-E : 163.36 SF RAISED DECK + SPA AREA (GREATER THAN 30") 163.36 SF FA COUNTABLE M-F : KEY - EXISTING MAIN / GROUND LVL. BASEMENT FLOOR WALL LABEL TOTAL WALL AREA (SQ FT)EXPOSED WALL AREA (SQ FT) 1 92.96 0 2 63.13 0 3 92.96 0 4 63.13 0 OVERALL TOTAL WALL AREA (SQ FT)312.18 EXPOSED WALL AREA (SQ FT)0 % OF EXPOSED WALL (EXPOSED / TOTAL)0.0% SUBGRADE 121 WALL EXPOSURE CALCULATION 0% (312.18 ACTUAL WALL SF) = 0.0 SF FA COUNTABLE EXISTING BASEMENT/ SUNGRADE FLOOR AREA CALCULATIONS - 121 MECHANICAL / SUBGRADE FLOOR AREA (SQ FT)215.47 (0.0% X 215.47)0.0121 SUBGRADE COUNTABLE FLOOR AREA (SQ FT) 215.47 FA - (0.0% EXPOSURE) = 0.0 FATOTAL BASEMENT COUNTABLE FLR AREA (SQ FT) PORCH/ DECK AREA COUNTABLE (SQ FT) EXTERIOR STORAGE AREA (SQ FT) GROUND FLOOR AREA (SQ FT) - FA GROUND PORCH/ DECK AREA (GROSS SQ FT) GROUND FLOOR STAIR & MISC. EXEMPTIONS: INT. GROUND FLOOR AREA (GROSS SQ FT HAB) GARAGE FLOOR AREA (SQ FT) - FA GARAGE FLOOR AREA (GROSS SQ FT) GROUND PORCH/ DECK AREA (COUNTABLE FA)163.36 -M / 304.35 -U (467.71) LEGEND (WALLS) EXPOSED WALL WALL BELOW GRADE Blkr Entry Porches/ Stairs Exempt 4.09 / 0.0 (FA) 163.36 -M / 304.35 -U = (467.71), therefore 0 FA ZN-004 EXISTING FLOOR DIAGRAMS & NUMERIC BREAKDOWNS 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC JANUARY 2021 AREA HABITABLE GARAGE PORCH/ DECK EXTERIOR STORAGE LEGEND EXISTING UPPER LVL. / FLOOR AREA PLANNING DIAGRAM : 1/8" = 1'-0"EXISTING ROOF AREA DIAGRAM : 1/8" = 1'-0" EXISTING UPPER FLOOR AREA CALCULATIONS - VICTORIAN (FRONT) + ALLEY MASSING EXISTING FLOOR AREA CALCULATIONS 340.96 (GROSS) UPPER FLOOR AREA - VICTORIAN (SQ FT) - FA 85.37UPPER PORCH/ DECK AREA VICTORIAN (GROSS SQ FT) UPPER FLOOR STAIR & MISC. EXEMPTIONS: INT. 1066.80 (FA) 35.80 (GROSS) UPPER FLOOR AREA - REAR (GROSS SQ FT HAB) 41.47 (GROSS) 299.49 (FA) 35.80 Open Stair Exemption 1102.60 (GROSS)UPPER FLOOR AREA- VICTORIAN (GROSS SQ FT) UPPER FLOOR STAIR & MISC. EXEMPTIONS: INT. UPPER FLOOR AREA - REAR : (SQ FT) - FA 41.47 Open Stair Exemption KEY - EXISTING UPPER LEVELS ALL SF (FA) COUNTABLE ROOF AREAS REPRESENTED ON UPPER LEVEL PLANNING DIAGRAM U-A :NOTE : KEY - EXISTING ROOF LVL. 1102.60 GROSS SQUARE FEET AREA 1066.80 SF FA COUNTABLE VICTORIAN 35.80 SQ FT EXEMPT AREA FOR OPEN STAIR (VICTORIAN) EXISTING UPPER FLOOR DECK AREA TOTAL (SQ FT) UPPER PORCH/ DECK AREA GARAGE (GROSS SQ FT) 1,366.29 (FA)TOTAL EXISTING UPPER FLOOR AREA (SQ FT) 85.37 SQ FT EXT PORCH (COUNTABLE FA) 218.62 SQ FT EXT DECK AREA (COUNTABLE FA) 340.96 GROSS SQUARE FEET AREA 299.49 SF FA COUNTABLE REAR MASSING 41.47 SQ FT EXEMPT AREA FOR OPEN STAIR (REAR STAIR) U-B : U-C : U-D : U-E : U-F : U-C (3,235.04 x .15%) = 485.26 all (3,235.04 x .15%) = 485.26 all 163.36 -M / 304.35 -U (467.71) 218.62 Floor Area Summary Existing Gross (Sq Ft)Existing Floor Area (Sq Ft)Proposed Gross (Sq Ft)Proposed Floor Area (Sq Ft)Reference ZN-004, ZN-006 ZN-005, ZN-007 Basement Habitable (Lower Subgrade Level)215.47 0.0 360.422,617.40 Main Level Habitable (Ground Floor)1,900.55 1,900.55 Upper Level Habitable (Existing) ZN-004 - ZN-007 Porch/ Stair Access / Patio/ Roof Deck Area Total 3,563.67 Hab / 372.16 Gar 3,327.92 (FA)3,484.87 (FA)5,709.07 Hab / 524.08 Gar Floor Area Allowable For 121 West Bleeker 3,235.04 square foot FA For SFR FA per SFR on 5,982.3 square foot lot 3,235.04 Total Allowable FA For SFR FA per SFR on 5,982.3 square foot lot with 250 SF HPC FA Bonus (Proposed) = 3,485.04 FA 524.08Main Level Garage (Ground Floor)372.16 61.08 149.08 Exterior Storage Area - Mechanical Usage 4.09 N/A N/A0.0 1,600.70 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 1,600.70 1,102.60 - V (FRT) / 340.96 - (ALY)576.0 - V (FRT) / 914.97 - (ALY)527.67 - V (FRT) / 847.0 - (ALY)1,066.80 - V (FRT) / 299.49 - (ALY) 0 FA Countable / 485.26 Allowable0 FA Countable / 485.26 Allowable467.71 (Total) / 130.72 (Exempt)922.01 (Total) / 64.34 (Exempt)ZN-005 EXISTING FLOOR DIAGRAMS & NUMERIC BREAKDOWNS 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC JANUARY 2021 AREA EXPOSED WALL WALL BELOW GRADE LEGEND HABITABLE TOTAL PROPOSED FLOOR AREA CALCULATIONS BASEMENT FLOOR AREA (SQ FT) GROUND FLOOR AREA (SQ FT) 2ND FLOOR AREA (SQ FT) PORCH/ DECK AREA (SQ FT) TOTAL PROPOSED FLOOR AREA (SQ FT) GARAGE FLOOR AREA (SQ FT) 2,617.40 / 360.42 (FA) 1,600.70 / 1,600.70 (FA) 3,124.45 (FA) Above Grade / 360.42 (FA) Subgrade (3,235.04 FA + 250 FA Bonus = 3,485.04FA) 3,484.87 FA 524.08 / 149.08 (FA) (3,235.04 x .15%) = 485.26 allowable PROPOSED BASEMENT FLOOR AREA DIAGRAM : 1/8" = 1'-0"PROPOSED FLOOR AREA CALCULATIONS FAR (Z-006) 10 ' 26'-35 8" 325.62 sq ft / 81.10 sq ft ex UNDERSIDE OF STRUCT. 1,490.97 / 1,374.67 (FA) 428.98 total / 0 (FA) 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK LIGHT SHADED AREA REPRESENTS 6000 SF R-6 SETBACKS PER COA LAND USE CODE WASH DRY 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K ELEVATOR SSP 36 x 60 UP L-001 Egress IRC Eg r e s s I R C STAIR TO MAIN L-002 MEDIA AREA / RECREATION ROOM L-003 BEDROOM HALLWAY L-005 LIGHTWELL L-002 LIGHTWELL L-002 A/V CLOSET RE F DW ELEVATOR MECH / STORAGE L-006 LAUNDRY ROOM L-007 ELECTRICAL/ DRY MECH L-008 PRIMARY MECHANICAL L-009 BUNK ROOM L-002 BEDROOM SUITE 1 L-002 BATHROOM SUITE 1 L-002 BEDROOM / FLEX ROOM L-002 BEDROOM SUITE 2 L-002 BATHROOM SUITE 1 L-002 BATHROOM/ POWDER L-010 BATHROOM BUNK AREA L-002 WALK OUT JACUZZI/ GROTTO AREA/ LIGHTWELL L-002 BAR - WINE AREA/ BEVERAGE PENINSULA L-004-B BAR - WINE AREA/ BEVERAGE L-004-A DROP DOWN PROJECTOR INTEGRATED MEDIA / MILLWORK WALL (LARGE PROJECTION - 100"+) BUILT-IN MEDIA & STORAGE SHELVING SYSTEMS BU I L T - I N M E D I A & ST O R A G E SH E L V I N G S Y S T E M S BUILT-IN CLOSET & STORAGE SHELVING SYSTEMS BU I L T - I N C L O S E T & ST O R A G E SH E L V I N G S Y S T E M S BU I L T - I N C L O S E T & ST O R A G E SH E L V I N G S Y S T E M S BUILT-IN JACUZZI & RAISED PLATFORM AREA - 6'-0" x 6'-0" SPA SHELVING/ ART NICHE WI N E ST O R A G E 8' x 5' AREA FOR TWO MATS / WORKOUT SPACE OPAQUE SKYLIGHT ABOVE 42 X 24 WEIGHT RACK 48 X 24 BIKE +9 +18+27+36 -2 FROM INTERIOR 64 X 28 TREADMILL 60 X 24 BENCH AREA GYM/ WORKOUT AREA L-002 MI R R O R MIRROR FLOOR TO CEILING 12' X 10' SLIDING GLAZED PANEL 24 T @ 1 1 " ( l a n d i n g s v . i . f . ) 25 R @ 6 - 1 / 2 " = 1 3 ' - 6 3 / 4 " T.O. F.F. Lower Level ELEV - 86'-8 1/4" (V.I.F.) T.O. Conc. Lower Level ELEV - 86'-7 1/4" (V.I.F.) T.O. Conc. Lower Level Mech ELEV - 85'-3 1/4" (V.I.F.) T.O. Conc. Grotto ELEV - 86'-3 1/4" (V.I.F.) (2 ) F U L L (2 ) T W I N RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EAST SIDE YARD ALLEY - PUBLIC ROW 26'-35 8"28'-5"12'-11" 8" 7' - 1 1 " 11 ' - 2 3 8" 35 ' - 4 " 4'-2" 24'-2"21'-4" 3' - 2 " 12 ' - 1 0 3 4" 22 ' - 4 5 8" 27'-15 8" (10) (12) (14) LP-A :2,617.40 GROSS SQUARE FEET TOTAL SUBGRADE PERIMETER CONSTRUCTION: 19.51% SUBGRADE WALL EXPOSURE, THEREFORE 510.65 SQ FT FA COUNTABLE 12 ' EXPOSED LW 8'-61 2"8'-111 2"8'-95 8" 10 ' 12 ' 8" 8.00 sq ft 10 ' 28'-5" 366.96 sq ft / 243.12 sq ft ex UNDERSIDE OF STRUCT. 12 ' EXPOSED LW 3'-8"21'-1"3'-8" 10 ' 12 ' 7'-11" UNDERSIDE OF STRUCT. 95.23 sq ft 10 ' 12 ' 12'-11" UNDERSIDE OF STRUCT. 155.01sq ft 10 ' 13 ' 4'-2" UNDERSIDE OF STRUCT. 56.34 sq ft / 2.17 sq ft ex 13 ' - 6 1 4" SKYLIGHT WALL EXPOSURE PROPOSED GRADE 10 ' 12 ' 11'-23 8" UNDERSIDE OF STRUCT. 134.37 sq ft 10 ' 13 ' - 0 1 4" 35'-4" UNDERSIDE OF STRUCT. 452.61 sq ft / 2.83 sq ft ex 13 ' - 6 1 4" 29'-8"5'-8" SKYLIGHT WALL EXPOSURE PROPOSED GRADE 12 ' 21'-4" UNDERSIDE OF STRUCT. (MECH) 255.99 sq ft 12 ' 3'-2" UNDERSIDE OF STRUCT. (MECH) 37.99 sq ft 10 ' 12 ' 12'-103 4" UNDERSIDE OF STRUCT. 154.74 sq ft 10 ' 26'-35 8" 331.78 sq ft / 81.10 sq ft ex UNDERSIDE OF STRUCT. 12 ' EXPOSED LW 10'-01 2"8'-111 2"7'-35 8" 10 ' 12 ' 27'-15 8" UNDERSIDE OF STRUCT. 341.61 sq ft 10 ' 12 ' 22'-45 8" UNDERSIDE OF STRUCT. 268.61 sq ft IF 250 SF FA BONUS GRANTED LP-A ZN-006 PROPOSED FLOOR DIAGRAMS & NUMERIC BREAKDOWNS 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC JANUARY 2021 AREA HABITABLE GARAGE PORCH/ DECK EXTERIOR STORAGE LEGEND PROPOSED MAIN FLOOR AREA PLANNING DIAGRAM : 1/8" = 1'-0"PROPOSED UPPER FLOOR AREA PLANNING DIAGRAM PROPOSED UPPER FLOOR AREA CALCULATIONS - VICTORIAN + ALLEY MASTER BEDROOM MASSING PROPOSED FLOOR AREA CALCULATIONS PROPOSED MAIN LEVEL / GROUND FLOOR AREA CALCULATIONS 1,608.70 (FA)GROUND FLOOR AREA (SQ FT) - FA 71.25 (Count) /64.34 (Exempt)GROUND PORCH/ DECK AREA (GROSS SQ FT) GROUND FLOOR STAIR & MISC. EXEMPTIONS: INT.0 1,600.70 (GROSS)GROUND FLOOR AREA (GROSS SQ FT HAB) GARAGE FLOOR AREA (SQ FT) - FA GARAGE FLOOR AREA (GROSS SQ FT)524.08 (GROSS) 149.08 (FA) Standard R-6 Zoning Allowance All SF 1:1 Countable 485.26 Lot Total Allowable 1600.70 GROSS SQ FT AREA 1600.70 SF FA COUNTABLE MAIN LVL. RESIDENCE UPPER FLOOR AREA - FRONT : VIC (SQ FT) - FA (293.39 Countable)UPPER PORCH/ DECK AREA (GROSS SQ FT) 527.67 (FA) 48.33 (GROSS) UPPER FLOOR AREA - BACK (GROSS SQ FT HAB) 847.0 (FA) 48.33 Open Stair Exemption 576.0 (GROSS)UPPER FLOOR AREA- FRONT (GROSS SQ FT HAB) 1st 250 Exempt / 2nd 250 - 50% UPPER FLOOR STAIR & MISC. EXEMPTIONS: INT. UPPER FLOOR AREA - BACK : MB (SQ FT) - FA 37.97 Open Stair Exemption 1,374.67 (FA)TOTAL PROPOSED UPPER FLOOR AREA (SQ FT) KEY - PROPOSED MAIN LEVEL MP-A : KEY - PROPOSED UPPER LEVELS MP-B : MP-C : MP-D : MP-E : MP-F :64.34 SQ FT EXT PRIMARY PORCH HISTORICAL / STREET FACING (EXEMPT FA) 455.53 SQ FT EXTERIOR PATIO 4" ABOVE GRADE CONDITION (EXEMPT FA) 37.5 SQ FT EXT REAR PATIO 4" ABOVE GRADE CONDITION (EXEMPT FA) 524.08 SF GARAGE 1st 250 SF EXEMPT 2nd 250 SF @ 1/2 = 125 SF 149.08 SF FA COUNTABLE 71.25 SQ FT EXTERIOR STAIR TO MASTER BECK AREA (COUNTABLE FA) 576.0 GROSS SQUARE FEET AREA 527.67 SF FA COUNTABLE VICTORIAN MASSING 48.33 SQ FT EXEMPT AREA FOR OPEN STAIR (VICTORIAN) 914.97 GROSS SQUARE FEET AREA 847.0 SF FA COUNTABLE ALLEY MASSING 67.97 SQ FT EXEMPT AREA FOR OPEN STAIR (REAR STAIR) 293.39 SQ FT MASTER DECK AREA (COUNTABLE FA) UP-A : UP-B : UP-C : UP-D : UP-E : UPPER FLOOR STAIR & MISC. EXEMPTIONS: INT. 914.97 (GROSS) 67.97 (GROSS) 485.26 Lot Total Allowable GROUND PATIO AREAS (GROSS SQ FT- NON FA)493.03 (GROSS) TOTAL PROPOSED GROUND FLOOR AREA (SQ FT)1,757.78 (FA) MP-B MP-E TOTAL PROPOSED FLOOR AREA CALCULATIONS BASEMENT FLOOR AREA (SQ FT) GROUND FLOOR AREA (SQ FT) 2ND FLOOR AREA (SQ FT) PORCH/ DECK AREA (SQ FT) TOTAL PROPOSED FLOOR AREA (SQ FT) GARAGE FLOOR AREA (SQ FT) 2,617.40 / 360.42 (FA) 1,600.70 / 1,600.70 (FA) 3,124.45 (FA) Above Grade / 360.42 (FA) Subgrade (3,235.04 FA + 250 FA Bonus = 3,485.04FA) 3,484.87 FA 524.08 / 149.08 (FA) (3,235.04 x .15%) = 485.26 allowable 1,490.97 / 1,374.67 (FA) 428.98 total / 0 (FA) IF 250 SF FA BONUS GRANTED Floor Area Summary Existing Gross (Sq Ft)Existing Floor Area (Sq Ft)Proposed Gross (Sq Ft)Proposed Floor Area (Sq Ft)Reference ZN-004, ZN-006 ZN-005, ZN-007 Basement Habitable (Lower Subgrade Level)215.47 0.0 360.422,617.40 Main Level Habitable (Ground Floor)1,900.55 1,900.55 Upper Level Habitable (Existing) ZN-004 - ZN-007 Porch/ Stair Access / Patio/ Roof Deck Area Total 3,563.67 Hab / 372.16 Gar 3,327.92 (FA)3,484.87 (FA)5,709.07 Hab / 524.08 Gar Floor Area Allowable For 121 West Bleeker 3,235.04 square foot FA For SFR FA per SFR on 5,982.3 square foot lot 3,235.04 Total Allowable FA For SFR FA per SFR on 5,982.3 square foot lot with 250 SF HPC FA Bonus (Proposed) = 3,485.04 FA 524.08Main Level Garage (Ground Floor)372.16 61.08 149.08 Exterior Storage Area - Mechanical Usage 4.09 N/A N/A0.0 1,600.70 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 ZN-005, ZN-007 1,600.70 1,102.60 - V (FRT) / 340.96 - (ALY)576.0 - V (FRT) / 914.97 - (ALY)527.67 - V (FRT) / 847.0 - (ALY)1,066.80 - V (FRT) / 299.49 - (ALY) 0 FA Countable / 485.26 Allowable0 FA Countable / 485.26 Allowable467.71 (Total) / 130.72 (Exempt)922.01 (Total) / 64.34 (Exempt)ZN-007 PROPOSED FLOOR DIAGRAMS & NUMERIC BREAKDOWNS 1/8" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC JANUARY 2021 AREA 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K UP UP UP DN 3.5" DN 4"DN 5" UP 8" ENTRY PORCH 100 ENTRY / STAIR 101 ENTRY CL. 102 LIVING ROOM 103 BEDROOM 1 / STUDY 104 CLOSET 105 BATHROOM 106 PANTRY 107 KITCHEN 108 DINING ROOM 108 COATS / MUDROOM 110 WEST ENTRY PORCH 109 INTERIOR BREEZEWAY 111 MEDIA / RECREATION 112 BATHROOM 113 1-1/2 STALL GARAGE 114 PATIO AREA 115 SPA AREA 116 UP UP UP OUTDOOR HOT TUB ME C H A N I C A L ACCESS TO MECHANICAL SUBGRADE AREA LOCATION OF MECHANICAL CRAWLSPACE BELOW OUTDOOR WOOD BURNING FIRELPACE FIREPLACE LIGHT SHADED AREA REPRESENTS NON HISTORICAL MASSING & FEATURES OF RESIDENCE TO BE REMOVED DN 7" DN 12" RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EAST SIDE YARD ALLEY - PUBLIC ROW 1 HPC-2.001 EXISTING MAIN LEVEL FLOOR PLAN :: 121 WEST BLEEKER SCALE : 1/4" = 1'-0" EXISTING FLOOR PLAN: MAIN LEVEL ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC :: JANUARY 2021 HPC-2.001 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K DN STAIRCLOSET 204 200 HALLWAY 201 HALL CL. 203 HALL CL. 202 BEDROOM 2 203 BATHROOM 205 MST. BATHROOM 207 DN HERS CLOSET A 208 DN DN MASTER BEDROOM 206 HIS CLOSET 210 HERS CLOSET B 209 MASTER DECK 211 ROOF DECK 214 LOFT AREA / BEDROOM 3 212 CLOSET 213 LIGHT SHADED AREA REPRESENTS NON HISTORICAL MASSING & FEATURES OF RESIDENCE TO BE REMOVED RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EAST SIDE YARD ALLEY - PUBLIC ROW 1 HPC-2.002 EXISTING UPPER LEVEL FLOOR PLAN :: 121 WEST BLEEKER SCALE : 1/4" = 1'-0" EXISTING FLOOR PLAN: UPPER LEVEL ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC :: JANUARY 2021 HPC-2.002 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K DN MASTER DECK 211 ROOF DECK 214 12 16 RIDGE RIDGE RIDGE RIDGE RI D G E RI D G E RI D G E RI D G E 12 16 12 16 12 16 12 1612 16 12 16 12 16 12 16 12 4 12 16 12 4 12 16 12 16 12 16 MASONRY CHIMNEY 12 16 12 16 12 16 12 8 12 16 12 16 12 16 12 8 12 8 12 4 12 16 12 16 12 2 12 2 12 2 12 2 RIDGE RIDGE RI D G E RIDGE LIGHT SHADED AREA REPRESENTS NON HISTORICAL MASSING & FEATURES OF RESIDENCE TO BE REMOVED RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EAST SIDE YARD ALLEY - PUBLIC ROW 1 HPC-2.003 EXISTING ROOF PLAN :: 121 WEST BLEEKER SCALE : 1/4" = 1'-0" EXISTING FLOOR PLAN: ROOF PLAN ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC :: JANUARY 2021 HPC-2.003 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK LIGHT SHADED AREA REPRESENTS 6000 SF R-6 SETBACKS PER COA LAND USE CODE WASH DRY 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K ELEVATOR SSP 36 x 60 UP L-001 Egress IRC Eg r e s s I R C STAIR TO MAIN L-002 MEDIA AREA / RECREATION ROOM L-003 BEDROOM HALLWAY L-005 LIGHTWELL L-002 LIGHTWELL L-002 A/V CLOSET RE F DW ELEVATOR MECH / STORAGE L-006 LAUNDRY ROOM L-007 ELECTRICAL/ DRY MECH L-008 PRIMARY MECHANICAL L-009 BUNK ROOM L-002 BEDROOM SUITE 1 L-002 BATHROOM SUITE 1 L-002 BEDROOM / FLEX ROOM L-002 BEDROOM SUITE 2 L-002 BATHROOM SUITE 1 L-002 BATHROOM/ POWDER L-010 BATHROOM BUNK AREA L-002 WALK OUT JACUZZI/ GROTTO AREA/ LIGHTWELL L-002 BAR - WINE AREA/ BEVERAGE PENINSULA L-004-B BAR - WINE AREA/ BEVERAGE L-004-A DROP DOWN PROJECTOR INTEGRATED MEDIA / MILLWORK WALL (LARGE PROJECTION - 100"+) BUILT-IN MEDIA & STORAGE SHELVING SYSTEMS BU I L T - I N M E D I A & ST O R A G E SH E L V I N G S Y S T E M S BUILT-IN CLOSET & STORAGE SHELVING SYSTEMS BU I L T - I N C L O S E T & ST O R A G E SH E L V I N G S Y S T E M S BU I L T - I N C L O S E T & ST O R A G E SH E L V I N G S Y S T E M S BUILT-IN JACUZZI & RAISED PLATFORM AREA - 6'-0" x 6'-0" SPA SHELVING/ ART NICHE WI N E ST O R A G E 8' x 5' AREA FOR TWO MATS / WORKOUT SPACE OPAQUE SKYLIGHT ABOVE 42 X 24 WEIGHT RACK 48 X 24 BIKE +9 +18+27+36 -2 FROM INTERIOR 64 X 28 TREADMILL 60 X 24 BENCH AREA GYM/ WORKOUT AREA L-002 MI R R O R MIRROR FLOOR TO CEILING 12' X 10' SLIDING GLAZED PANEL 24 T @ 1 1 " ( l a n d i n g s v . i . f . ) 25 R @ 6 - 1 / 2 " = 1 3 ' - 6 3 / 4 " T.O. F.F. Lower Level ELEV - 86'-8 1/4" (V.I.F.) T.O. Conc. Lower Level ELEV - 86'-7 1/4" (V.I.F.) T.O. Conc. Lower Level Mech ELEV - 85'-3 1/4" (V.I.F.) T.O. Conc. Grotto ELEV - 86'-3 1/4" (V.I.F.) (2 ) F U L L (2 ) T W I N 75'-115 8" 27'-115 8"28'-5"14'-7"5' 75'-115 8"5'-83 4" 27'-115 8"25'23' 10'-21 2"10'-31 2"4'-6" 8'-81 2"10'-31 2"8'-115 8"3'22'-5"3' 49 ' - 0 3 8" 4' 13 ' - 8 3 4" 24 ' - 0 5 8" 4' 3' - 3 " 49 ' - 0 3 8" 37 ' 12 ' - 0 3 8" 18'-17 8" 5' - 9 " 5' - 2 7 8" 5' - 1 0 5 16 " 18'-15 8"5'-35 8" RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EAST SIDE YARD ALLEY - PUBLIC ROW PLAN NOTES DIMENSIONS: DO NOT SCALE DRAWINGS. SCOPE ENTAILS THE PARTIAL DEMOLITION AND PRESERVATION OF AN EXISTING HISTORIC HOUSE, AND CONSTRUCTION OF A NEW BASEMENT AND ADDITION LAYOUT OF THE DESIGN RELIES ON ALIGNMENTS AND HOLD DIMENSIONS AS WELL AS POSSIBLE ADJUSTMENTS DUE TO FIELD CONDITIONS AND TRADE COORDINATION. ALL WORK MUST BE CHALKED AND LAID OUT BY THE GC PRIOR TO CONSTRUCTION. ALL DISCREPANCIES MUST BE RECTIFIED BY THE GC AND ARCHITECT PRIOR TO CONSTRUCTION. CONTENT LOCATION: ELEVATIONS: SHEET A-30.01 BUILDING SECTION: SHEET A-31.01 PARTITIONS: SHEET A-80.01 PARTITIONS: SEE SHEET A-80.01 -ALL NEW PARTITIONS SHALL BE TYPE A41 UNLESS OTHERWISE NOTED. -ALL FURRING SHALL BE MIN. 312" + FINISH UNLESS OTHERWISE DIMENSIONED. PARTITION TYPES SAFETY GLAZING ALL GLASS SHALL BE TEMPERED/SAFETY GLASS UNLESS OTHERWISE NOTED EMERGENCY ESCAPE ALL EMERGENCY ESCAPE EGRESS WINDOWS SHALL HAVE SILLS 40" A.F.F. UNLESS OTHERWISE NOTED (SEE ELEVATION AND SECTION DWGS). SYMBOLS LEGEND * SEE G-002.00 FOR ADDITIONAL SYMBOLS A PARTITIONS & WALLS:CEILING OBJECTS:LEGEND: TRUE NORTH 14.7 O 1 HPC-2.004 PROPOSED LOWER LEVEL FLOOR PLAN :: 121 WEST BLEEKER SCALE : 1/4" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-2.004 PROPOSED LOWER LEVEL HPC JANUARY 2021 FLOOR PLAN: 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K UP ENTRY PORCH (OPENED) M-100 ENTRY / STAIR TO UPPER GUEST SUITE M-103 24" MICRO/ COFFEE DRAWERS BELOW DW PIANO/ DEN M-104 BUILT IN CLOSET KITCHEN PENINSULA M-107-B TWO STALL GARAGE M-113 30" REF 24" FRE KITCHEN M-107-A BENCH48" FIREPLACE (OPEN TWO SIDES) UTILITIES TO BE LOCATED ALONG EAST STAIR WALL - 48" HEIGHT PROPOSED LIVING AREA M-105 121 ENTRY AREA (MAIN) M-101 MUDROOM M-111 UP DN 6'-9" x 30" TALL SERVING BUFFET / STORAGE BELOW 24" DOUBLE OVENS BELOW RANGE STORAGE / PANTRY 45 " G A S / 6 BU R N E R C O O K T O P W/ D O W N D R A F T VE N T STORAGE 8' x 4' TABLE REPRESENTED 121 STAIR / ELEVATOR HALLWAY / CIRCULATION M-108 SSP 36 x 60 ELEVATOR M-109 DINING AREA M-106 ON GRADE PATIO AREA M-104-A GARAGE HALL M-110 UP 30" TALL PLANTING FOR SCREENING FROM BLEEKER 24" TALL INTEGRATED FIRE FEATURE & LIGHTWELL EGRESS SHAFT ST O R A G E B E L O W CO U N T E R COUNTER APPLIANCE GARAGE w/ SHELVING STORAGE OPAQUE SKYLIGHT DW DN DN BUILT IN HEARTH PROPOSED STAIRS (TUBE STEEL CHANNEL) TO MASTER DECK/ BEDROOM AREA ABOVE GARAGE GRATED LIGHTWELL CONDITION GRATED LIGHTWELL CONDITION FIRE FEATURE WINDOW BUMP OUT WI N D O W BU M P O U T 13 T @ 11" (landings v.i.f.) 14 R @ 7-3/4" = 9'-1/2" 1 T @ 1-2" (landing 4') 2 R @ 7" = 1'-2" UP POWDER M-102 COATS 20 T @ 1 1 " ( l a n d i n g s v . i . f . ) 21 R @ 6 - 3 / 4 " = 1 1 ' - 9 3 / 4 " 24 T @ 1 1 " ( l a n d i n g s v . i . f . ) 25 R @ 6 - 1 / 2 " = 1 3 ' - 6 3 / 4 " 20 T @ 1 ' - 4 " 2 R @ 7 " = 1 ' - 2 " 19 T @ 12" (landings v.i.f.) 20 R @ 7 3/8" = 12'-4" T.O. F.F. Conc. Garage ELEV - 101'-5" (V.I.F.) T.O. Plwd. Garage ELEV - 101'-0" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plwd. Main Level ELEV - 100'-0" (V.I.F.) T.O. F.F. Entry ELEV - 101'-5" (V.I.F.) T.O. F.F. Entry ELEV - 101'-5" (V.I.F.) 2 T @ 1'-6" (landings v.i.f.) 3 R @ 6-3/4" = 1'-8 1/4" T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plwd. Main Level ELEV - 100'-0" (V.I.F.) T.O. F.F. Exterior Patio ELEV - 100'-2 3/4" (V.I.F.) T.O. F.F. Exterior Patio ELEV - 101'-4 3/4" (V.I.F.) -2 SLOPE FROM INTERIOR -2 SLOPE FROM INTERIOR -1 SLOPE FROM INTERIOR G E PROPOSED RESTORATION OF ( PER HISTORICAL IMAGERY) ORIGINAL OPEN NORTH ENTRY PORCH + DETAILING CU-1 CU-2 CU-3 CU-4 CU-5 BENCH W/ HOOKS ABOVE CUBBIES COATS/ HANGING POWDER M-112 12 ' - 5 7 8" 24 ' - 0 5 8" 17 ' - 8 3 4" 4' 1' - 4 9 16 " 18'-17 8"75'-115 8"5'-83 4" 22'-111 2"25'-01 2"27'-115 8" 16'-113 8" 12 ' - 6 3 4" 11 ' - 5 7 8" 7' - 3 " 5' - 2 7 8" 77'-2"5'-35 8"16'-111 4" 10'-35 8"14'-7"28'-5"27'-115 8"1'-23 8" 3'22'-5"3' 5' - 9 1 8" 1'-23 8" 53 ' - 0 3 8" 1' - 1 1 2" 5' - 9 " 4' 23 ' 26 ' - 0 3 8" RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EAST SIDE YARD ALLEY - PUBLIC ROW PLAN NOTES DIMENSIONS: DO NOT SCALE DRAWINGS. SCOPE ENTAILS THE PARTIAL DEMOLITION AND PRESERVATION OF AN EXISTING HISTORIC HOUSE, AND CONSTRUCTION OF A NEW BASEMENT AND ADDITION LAYOUT OF THE DESIGN RELIES ON ALIGNMENTS AND HOLD DIMENSIONS AS WELL AS POSSIBLE ADJUSTMENTS DUE TO FIELD CONDITIONS AND TRADE COORDINATION. ALL WORK MUST BE CHALKED AND LAID OUT BY THE GC PRIOR TO CONSTRUCTION. ALL DISCREPANCIES MUST BE RECTIFIED BY THE GC AND ARCHITECT PRIOR TO CONSTRUCTION. CONTENT LOCATION: ELEVATIONS: SHEET A-30.01 BUILDING SECTION: SHEET A-31.01 PARTITIONS: SHEET A-80.01 PARTITIONS: SEE SHEET A-80.01 -ALL NEW PARTITIONS SHALL BE TYPE A41 UNLESS OTHERWISE NOTED. -ALL FURRING SHALL BE MIN. 312" + FINISH UNLESS OTHERWISE DIMENSIONED. PARTITION TYPES SAFETY GLAZING ALL GLASS SHALL BE TEMPERED/SAFETY GLASS UNLESS OTHERWISE NOTED EMERGENCY ESCAPE ALL EMERGENCY ESCAPE EGRESS WINDOWS SHALL HAVE SILLS 40" A.F.F. UNLESS OTHERWISE NOTED (SEE ELEVATION AND SECTION DWGS). SYMBOLS LEGEND * SEE G-002.00 FOR ADDITIONAL SYMBOLS A PARTITIONS & WALLS:CEILING OBJECTS:LEGEND: TRUE NORTH 14.7 O HPC-2.005 1 HPC-2.005 PROPOSED MAIN LEVEL FLOOR PLAN :: 121 WEST BLEEKER SCALE : 1/4" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP PROPOSED MAIN LEVEL HPC JANUARY 2021 FLOOR PLAN: 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K GUEST MASTER SUITE U-201 GUEST MASTER SUITE STAIR U-200 GUEST MASTER SUITE CLOSET U-202 GUEST MASTER SUITE CLOSET U-203 SEASONAL STORAGE U-204 BUILT IN HANGING/ SHELVING BUILT IN DESK/ STORAGE MEDIA OPEN TO BELOW DN 121 STAIR / ELEVATOR MASTER HALLWAY U-206 SSP 36 x 60 ELEVATOR U-205 ORTAL (2 SIDED) BUILT IN FIREPLACE BUILT-IN CABINETRY W/ DOORS, SHELVES, & BED RECESSED INTO AREA. INTEGRATED LIGHTING CU S T O M B U I L T I N SH E L V I N G W / D O O R S CU S T O M B U I L T I N SH E L V I N G W / D O O R S ROOF DECK-MASTER U-214 MASTER CLOSET A U-207 MASTER BEDROOM SUITE U-210 MASTER BATHROOM U-211 CUSTOM JACUZZI & RAISED PLATFORM AREA - 5'-0" x 5'-0" SPA BUILT-IN DESK AND STORAGE MASTER OFFICE U-209 M-212 TOILET M-213 WASH MST. CLOSET B U-208 DN 4 T @ 11" (landings v.i.f.) 5 R @ 6-11/16" = 2'-9 1/2"UP 13 T @ 11" (landings v.i.f.) 14 R @ 7-3/4" = 9'-1/2"DN GUEST MASTER BATHROOM U-205 20 T @ 1 1 " ( l a n d i n g s v . i . f . ) 21 R @ 6 - 3 / 4 " = 1 1 ' - 9 3 / 4 " 19 T @ 12" (landings v.i.f.) 20 R @ 7 3/8" = 12'-4" T.O. F.F. Upper Level ELEV - 112'-1" (V.I.F.) T.O. Plwd. Upper Level ELEV - 111'-10" (V.I.F.) T.O. F.F. Master Deck ELEV - 111'-11 1/2" (V.I.F.) T.O. Plwd. Master Deck / Garage ELEV - 111'-5 1/4" (V.I.F.) T.O. F.F. Upper / Mater Suite Level ELEV - 112'-3/4" (V.I.F.) T.O. Plwd. Upper Level ELEV - 111'-9 3/4" (V.I.F.) PROPOSED RESTORATION OF (BELIEVED PER HISTORICAL IMAGERY & EXISTING CONDITIONS) ORIGINAL SOUTH FACADE ROOF MASSING + FORM CU-1 CU-2 CU-3 CU-4 CU-5 STACKED W/D 23 ' - 7 3 4" 24 ' - 0 5 8" 12 ' - 5 7 8" 27'-115 8"25' 18'-17 8"75'-115 8"5'-83 4" 23' 18'10'-83 4" 70'-115 8"10'-35 8" 27'-115 8"25'18' 12'13' 18'-15 8" 16'-111 4" 1'-23 8" 18'-115 16" 12'13' 1' - 1 1 2" 53 ' - 0 3 8" 5' - 9 " 40 ' 14 ' - 1 7 8" 4' 9' - 0 3 8" 13 ' - 1 1 5 8" 26 ' - 0 3 8" RE A R A L L E Y ( S O U T H ) - P U B L I C R O W EAST SIDE YARD ALLEY - PUBLIC ROW PLAN NOTES DIMENSIONS: DO NOT SCALE DRAWINGS. SCOPE ENTAILS THE PARTIAL DEMOLITION AND PRESERVATION OF AN EXISTING HISTORIC HOUSE, AND CONSTRUCTION OF A NEW BASEMENT AND ADDITION LAYOUT OF THE DESIGN RELIES ON ALIGNMENTS AND HOLD DIMENSIONS AS WELL AS POSSIBLE ADJUSTMENTS DUE TO FIELD CONDITIONS AND TRADE COORDINATION. ALL WORK MUST BE CHALKED AND LAID OUT BY THE GC PRIOR TO CONSTRUCTION. ALL DISCREPANCIES MUST BE RECTIFIED BY THE GC AND ARCHITECT PRIOR TO CONSTRUCTION. CONTENT LOCATION: ELEVATIONS: SHEET A-30.01 BUILDING SECTION: SHEET A-31.01 PARTITIONS: SHEET A-80.01 PARTITIONS: SEE SHEET A-80.01 -ALL NEW PARTITIONS SHALL BE TYPE A41 UNLESS OTHERWISE NOTED. -ALL FURRING SHALL BE MIN. 312" + FINISH UNLESS OTHERWISE DIMENSIONED. PARTITION TYPES SAFETY GLAZING ALL GLASS SHALL BE TEMPERED/SAFETY GLASS UNLESS OTHERWISE NOTED EMERGENCY ESCAPE ALL EMERGENCY ESCAPE EGRESS WINDOWS SHALL HAVE SILLS 40" A.F.F. UNLESS OTHERWISE NOTED (SEE ELEVATION AND SECTION DWGS). SYMBOLS LEGEND * SEE G-002.00 FOR ADDITIONAL SYMBOLS A PARTITIONS & WALLS:CEILING OBJECTS:LEGEND: TRUE NORTH 14.7 O 1 HPC-2.006 PROPOSED UPPER LEVEL FLOOR PLAN :: 121 WEST BLEEKER SCALE : 1/4" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-2.006 PROPOSED UPPER LEVEL HPC JANUARY 2021 FLOOR PLAN: 121 WEST BLEEKER E 1/2 LOT C, LOT D & W 1 2 LOT E - BLOCK 58 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 10 ' F R O N T Y A R D S E T B A C K 5' SIDE YARD SETBACK 5' SIDE YARD SETBACK 5' R E A R Y A R D S E T B A C K (G A R A G E ) 10 ' H A B I T A B L E R E A R S E T B A C K RE A R A L L E Y ( S O U T H ) - P U B L I C R O W 12 16 CEDAR SHINGLE ROOFING PROPOSED FLASH & WATERPROOF AS NECESSARY RIDGE RIDGE RIDGE RIDGE RI D G E RI D G E RI D G E RI D G E 12 16 12 16 12 16 12 1612 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 12 16 CEDAR SHINGLE ROOFING PROPOSED FLASH & WATERPROOF AS NECESSARY MASONRY CHIMNEY CUSTOM JACUZZI & RAISED PLATFORM AREA - 5'-0" x 5'-0" SPA FLAT ROOF STANDARD STONE BALLAST TOPPING PROPOSED SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 NON-PERMEABLE DECK AREA : PROPOSED STONE DECKING SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 SLOPE 2 MIN SLOPE 2 MIN SL O P E 2 M I N SL O P E 2 M I N 0 0 0 0 ROOF DECK-MASTER U-214 T.O. F.F. Master Deck ELEV - 111'-11 1/2" (V.I.F.) T.O. Plwd. Mst. Deck / Garage ELEV - 111'-5" (V.I.F.) T.O. Plwd. Connector ELEV - 111'-10" (V.I.F.) FLAT ROOF WITH NEW RUBBER DRAINAGE MATT, STONE BALLAST & WATERPROOFING AS NECESSARY. FLASH & WATERPROOF ROOFING CONDITIONS AS REQUIRED. PV - 1 34 PANEL PV ROOF SYSTEM SITUATED @ 45 DEGREES PV - 2 PV - 1 8 PV - 1 9 PV - 2 0 PV - 3 PV - 4 PV - 2 1 PV - 5 PV - 2 2 PV - 2 3 PV - 6 PV - 7 PV - 2 4 PV - 2 5 PV - 8 PV - 9 PV - 2 6 PV - 1 0 PV - 2 7 PV - 2 8 PV - 1 1 PV - 1 2 PV - 2 9 PV - 3 0 PV - 3 1 PV - 1 3 PV - 1 4 PV - 1 5 PV - 3 2 PV - 1 6 PV - 3 3 PV - 3 4 PV - 1 7 NON REFLECTIVE MATTE / PAINT LOCKED METAL ROOFING PROPOSED 12 1 PROPOSED RESTORATION OF (BELIEVED PER HISTORICAL IMAGERY & EXISTING CONDITIONS) ORIGINAL SOUTH FACADE ROOF MASSING + FORM FP CHIMNEY NON REFLECTIVE MATTE / PAINT LOCKED METAL ROOFING PROPOSED 12 12 12 12 FLAT ROOF WITH NEW RUBBER DRAINAGE MATT, STONE BALLAST & WATERPROOFING AS NECESSARY. FLASH & WATERPROOF ROOFING CONDITIONS AS REQUIRED. EAST SIDE YARD ALLEY - PUBLIC ROW ROOF PLAN NOTES LEGEND: ROOFING SLOPES: 1. FOR ROOFING MATERIALS AND NOTES SEE 'MATERIAL NOTES ON A-30 SERIES ELEVATION SHEETS. 2. ROOF SLOPES ARE SHOWN DIRECTLY ON ROOF PLAN. 3. ALL FLAT ROOFS AND BALCONIES SHALL SLOPE A MINIMUM OF 2% TOWARD DRAINS. 3529,'(´3/<:22'6+($7+,1*29(5[ 675,33,1*$´2&723529,'(6/23(72'5$,16 AT FLAT ROOF CONDITIONS. 5. WATER SHALL NOT BE ALLOWED TO PUDDLE OR POOL ON ANY PART OF THE ROOF. NO OBSTACLE SHALL IMPEDE THE FLOW OF WATER TO DESIGNATED DRAIN. &5,&.(766+$//%(&216758&7(':,7+´&'; PLYWOOD AND SHALL BE PROTECTED AND FLASHED WITH METAL CRICKET SADDLES WITH LOCKED AND SOLDERED JOINTS. GUTTERS, DOWNSPOUTS AND ROOF DRAINS: 7. GUTTERS SHALL BE CONSTRUCTED 24 GA PAINTED STEEL WIT ´(;3$16,21-2,176 EVERY 30 FT (MAX) *877(566+$//6/23($0,12)´72:$5' DOWNSPOUTS. 9. SEE ROOF PLAN AND ELEVATIONS FOR DOWNSPOUT LOCATIONS. 10. PROVIDE DOME WIRE BASKET AT EACH DOWNSPOUT/DRAIN LOCATION. 11. CONTRACTOR SHALL TEST ALL CONCEALED DOWNSPOUTS FOR LEAKAGE PRIOR TO CLOSE IN. CONTRACTOR SHALL PROVIDE A 10 YEAR WARRANTY AGAINST LEAKAGE. 12. ROOF DRAINAGE TO BE CONNECTED TO AN APPROVED CITY DRAINAGE DEVICE. ALL RAINWATER TO BE DIRECTED TO STREET OR APPROVED OUTLET. ATTIC VENTILATION AND ROOF VENTS: 13. VENTS AT FLAT ROOFS AND ROOF STACKS SHALL PROJECT ABOVE THE ROOF THE MINIMUM DISTANCE REQUIRED BY THE CODE AND SHALL BE LOCATED IN AREAS NOT VISIBLE FOR THE STREET. EXACT LOCATIONS TO BE COORDINATED WITH THE ARCHITECT PRIOR TO INSTALLATION. 14. ALL VENT AND ROOF STACKS TO HAVE RAIN PROTECTION CAPS. 15. PROVIDE WATERPROOFING, FLASHING AND COUNTER FLASHING AT ALL ROOF PENETRATIONS. ALL SEAMS AND JOINTS SHALL BE CAULKED AND SEALED. 16. COLOR OF EXPOSED ROOF VENTS AND STACKS SHALL MATCH THE COLOR OF THE ROOF TILES OR FINISHED ROOF MATERIAL. 17. ATTIC VENTILATION SHALL BE A MI. OF 1 /150 OF THE AREA TO BE VENTILATED AND SHALL HAVE A VAPOR RETARDER HAVING A TRANSMISSION RATE NOT EXCEEDING 1 PERM INSTALLED ON THE WARM SIDE OF THE INSULATION. 18. VENTILATION IS NOT REQUIRED IN AREAS WHERE ROOF INSULATION IS INSTALLED BETWEEN RAFTERS WITH NO AIR SPACE BETWEEN INSULATION AND ROOF SHEATHING. 19. VENTS SHALL BE CONSTRUCTED WITH 24 GA PAINTED METAL. LOUVERS AND 1/4x1/4x WIRE CLOTH SHALL CONFORM TO SMACNA GUIDE LINES. LOUVERS SHALL BE CONSTRUCTED TO DEFLECT DRIVEN RAIN. ROOF DRAINAGE (FLAT ROOF CONDITIONS (WHERE APPLICABLE): ALL ROOFS SHALL BE PROVIDED WITH ROOF DRAINS AND OVERFLOW DRAINS. DRAINS SHALL BE &211(&7('72´/($'(56 *$/9$1,=('67((/  SECONDARY OVERFLOW PIPING SHALL BE INDEPENDENT OF PRIMARY PIPING AND SHALL DISCHARGE IN A VISIBLE, CONSPICUOUS LOCATION, $%29(*5$'(29(5)/2:'5$,16+$//(;7(1'´ ABOVE THE ROOF. ´6,=,1*2)3,3(6 $7$´)7522)6/23( :,// PROVIDE DRAINAGE FOR 2,900 SF OF ROOF AREA. STRAINERS SHALL BE PROVIDED. STRAINERS 6+$//127(;7(1'/(667+$1´$%29(7+( SURFACE OF THE ROOF IMMEDIATELY ADJACENT TO THE DRAIN. TRUE NORTH 14.7 O 1 HPC-2.007 PROPOSED ROOF PLAN :: 121 WEST BLEEKER SCALE : 1/4" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-2.007 PROPOSED HPC JANUARY 2021 ROOF PLAN: I 1 \\� WI I I I \\ ^U I I I 1 �I ,\ W z o ob \\ W V _ -- ---- — �z a as I CY)i ,,,- I, - _ -- \ m w �.+ ` EAST SIDE-YAR-11AL0 PUBLIC IqW_--- - �1-Q ��__��_______ Cn ❑ Y LU W v , m ----- a �- 7----------------= Y i' d d \ y \\ ! '' �' --�-- � �---�-- r! I � --1 / N @ '\ R 0 \\ !r - -! 1 I N 1 w1 1 �} //Q �11 ` \ 11� Q \ A r �1� I ` r!1 � I \ y T !f f------------ I1 11 I 1 I \ 1 4 JJI I s l r �Ole i9 ,V 1l d +' a N Il p µ a a l t IIG 14 a V j1 G 1\ m 'a !1 a ! . a r �I`' ---------- 'Co_- \ 80 / 1 � I ,�1--1----- i�-- �� // v \ 9 I 1 f /I d fl 1 51 "50'g9 �Vhl()O,CaO' II yy t II r i , 1 \ J 1 1 PROPERTY LINE 11 - ' _ 1� 1, � yr /\ /� � - OWNERSHIP UTILITII3S TO BE `\ LOdATgDALONG T S AIR WALL - ItAI 1y Owners: / y ! \ •� I \\ \\ \\ / / \ = C C _ C 48' HEI HT PROPO ED ` 1 1 y 121 W Bleeker LLC 121 West Bleeker Street I �� !! �__ _ 5'SIDE YARD SETBACK Aspen s , p O 81611 1 1 \ ----- --------------- -- GENERAL CONTRACTOR Kaegebein Fine Homebuikding I GRATED Z'ELr_ Ii I II \\\\ II 1y PO Box 1570 Carbondale, Colorado 81623 T970-510-5797 CONB6I®L II I 1 IIlr 1 i www_klhamebuildin -corn T- DESIGNE,R ---- iPROJECT CITY REPRESENTATIVE PO BOX 79281 Friday Design I------ LI Aspen, Colorado81612 T:970.309.0695 www_lfiday-com . wo ___------- _ _� FII l+IIIi1IIliI !II II IIOO -1 1 1III SURVEY EY ENGINEER Boundaries Unlimited Inc.00 923 Cooper Avenue, Suite 201 r Glenwood Springs, CO 81601 lva J L O O :A:T:970.945.5252 I I www_bu-inc-cam A�� ' J IiI CIVIL ENGINEER Boundaries Unlimited knc. _IiIIIIIII == 923 Cooper Avenue, Suite 241 Glenwood Springs, CO 81601 T:970.945.5252 www-bu-inacom Lm6j aL—u IIIIIIIIIIIIII�II� a lIIIIII1IIIIIIIl ----- /YI ------- ----------- IIkII�IIII STRUCTURAL ENGINEER 1 0 0 James Jackson Romeo, P.E. � Structural Design Consultant, LLC IiI'I 3901 Mountain Drive#11 Glenwood Springs, CO 81601 ! 30"TALPLANTINGI�_________ L SCREENING �' 97Q94742�� wom ww-strucluacFOR 1 121 WEST BLEEKER FROM BLEEKER ,119 E ll2 LOT CLOT D & „ 7 I ' W II JLa\I31\ IW , I 11 / ! WI LOT EBLOCK 582 �-------- O�' r / _ --- -- PROPOSED ITIVE I SPECIES DE�IYLJOUS TREES (2 to 3 A PEN) CT) 00 FOR SCREENING FROM BLEEKER\ ~ '��'WZFO �� --_--__--- 5' SIDE YARD SF-TBACK--- 7--------__~r _ \ 11 •gQy\-. _ III IIII I IIIIII II 'PROPERTY - - - LINE y j 03 co ro Q 1\fjl1y]1 POEDCONCEPTUAL LAND SCAPE PLAN 121 WEST BLEEKER /00 SEAL 8 SCALE>'114" 1'-0" ISSUANCE DATE CONCEPTUAL LANDSCAPE PLAN NOTES & DIAGRAM LEGEND: TRUE EXISTING COTTONWOOD SPECIES: EXISTING NATIVE (ASPEN) SPECIES: EXISTING NATIVE (36-42" MAX) EXISTING NATIVE (36-42" MAX) PROPOSED STONE SANDSET PAVERS: PROPOSED LAWN AREAS: PROPOSED GRAVEL AREAS: PROPOSED STONE (PATIO) AREAS: PROPOSED POURED CONCRETE SLAB AREAS: NORTH ° 0 2'-85'-4 8" SHRUB SPECIES: SHRUB SPECIES: 14.7 FLAMED SURFACE PENNSYLVANIA BLUE COLORADO TRADITIONAL WEST END LAWN TYPICAL WASHED I PEBBLED NO 5 GRAVEL FULL WATERPROOF AND SNOWMELT TYPICAL POURED CONCRETE SLAB PER 01 HPC 1 CONCEPTUAL ------ ` STONE PROPOSED 2-114" THICK MIN. SEEDING - SOD MIXTURE PROPOSED. SURFACE MIX DETAILING PROPOSED. FINISH PROPOSED ENGINEERING. 6" MINIMUM THICKNESS. SIZE AND LAYOUT TO BE DETERMINED IRRIGATION AS REQUIRED AS FLAMED PENNSYLVANIA BLUESTONE SMOOTH FINISH. 2-1I2" THICK MATERIAL FINISH. PATIO TO BE DESIGNED FOR RUNOFF WATERSHED DRAINAGE. ALL SURFACE WATER TO BE N SCALE: 3/ 6 —�" SCALE COLLECTED PER DRYWALLS AS SPECIFIED PROJECT# 121- BLEEKER DRAWING TITLE: PROPOSED LANDSCAPE PLAN: DRAWING NO:FM- HPC-2"008 HPC JANUARY 2021 1.RESTORE FRONT ENTRY (BLEEKER STREET) PORCH TO OPEN CONDITION PER HISTORICAL RECORD. RAILING AND ORNATE DETAILING, POSTS TO BE RESTORED / SIMPLIFIED TO ORIGINAL DETAILING CONDITIONS PER HISTORICAL IMAGING. REFER TO PROPOSED ELEVATIONS. 2.NON-HISTORIC WEST SIDE YARD PORCH & SECONDARY ENTRY / MUDROOM / TIE IN TO ENCLOSED BREEZEWAY / CONNECTOR TO BE REMOVED. WEST WALL HISTORIC WINDOW OPENINGS AND DORMER TO REMAIN AND BE RESTORED PER HISTORIC CONDITIONS. ALL NON-HOSTORIC DETAILING TO BE REMOVED ACCORDINGLY. 3.NON-HISTORIC 4/12 GABLE MASSING DIRECTLY ABUTTED TO THE SOUTH ELEVATION OF THE HISTORIC VICTORIAN TO BE REMOVED IN ITS ENTIRETY. PER HISTORICAL IMAGERY AND EXISTING IMAGING - DESIGN INTENT TO RE-ESTABLISH THE HISTORICAL 16/ 12 MASS AND FORM CONSISTENT WITH THE EXISTING HISTORICAL CONDITIONS "MIRRORED" E-W / N-S. DETAILING TO MATCH EXISTING HISTORICAL CONDITIONS. SOUTH WEST REAR CORNER OF VICTORIAN TO BE RE-ESTABLISHED PER PROPOSED ELEVATIONS AND PLANNING. 4.EAST ELEVATION MASSING DIRECTLY ABUTTED TO EXISTING VICTORIAN TO BE REMOVED. SOUTH EAST REAR ORIGINAL VICTORIAN CORNER TO BE RE-ESTABLISHED PER PROPOSED ELEVATIONS AND PLANNING. 5.EXISTING GARAGE AND SECONDARY 16/12 GABLE MASSING AREA OF THE EXISTING HOME TO BE REMOVED IN ITS ENTIRETY. PROPOSED NEW MASSING BRINGS ALL PROPOSED MASSING TO BE LEGALLY DEVELOPED WITHIN THE PROPERTY BOUNDARY. 6.PER HISTORICAL IMAGING, CHIMNEY HEIGHT + PROPORTION WAS LIKELY RECONSTRUCTED PER 1990'S ADDITIONS. PROPOSE TO RESTORE / RECONSTRUCT HISTORICAL VICTORIAN CHIMNEY TO MORE ACCURATE HISTORICAL DESIGN INTENT. EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) WE S T S I D E Y A R D PR O P E R T Y L I N E 5' S I D E Y A R D S E T B A C K 5' S I D E Y A R D S E T B A C K 16 12 16 12 EA S T S I D E Y A R D AL L E Y S T A R T 25' R-6 Height Limit T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) 7894 T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. F.F. Main Lvl. (Victorian) ELEV - 101'-5" (V.I.F.) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) 1/3 Height of 16/12 Historic Gable Roof ELEV - 119'-3 3/4" (V.I.F.) 1 4 12 8 12 2 3 3 3 5 5 4 12 HISTORIC RESTORATION KEY / DEMOLITION : AREAS SHADED TO BE REMOVED 6 5 3 4 EA S T S I D E Y A R D AL L E Y S T A R T EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) 5' S I D E Y A R D S E T B A C K 5' S I D E Y A R D S E T B A C K WE S T S I D E Y A R D PR O P E R T Y L I N E 7894 T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) 25' R-6 Height Limit Historic Victorian + Associative Massing T.O. F.F. Main Lvl. (Victorian) ELEV - 101'-5" (V.I.F.) 5 5 5 5 5 2 2 12 9 12 1 HPC-3.001 EXISTING ELEVATION/ SECTIONS - NORTH ELEVATION (121 BLEEKER) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-3.001 2 HPC-3.001 EXISTING ELEVATION/ SECTIONS - NORTH ELEVATION (INTERIOR : CONNECTOR / ADDITION) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" EXISTING HPC JANUARY 2021 ELEVATIONS 7894 PR O P E R T Y L I N E ED G E O F C U R B : BL E E K E R S T R E E T 7894 7895.4 ALLEY ASPHALT RE A R Y A R D PR O P E R T Y L I N E 5' R E A R Y A R D SE T B A C K ( G A R A G E ) 10 ' R E A R Y A R D S E T B A C K (H A B I T A B L E ) 10 ' F R O N T Y A R D SE T B A C K 7895 7896 7894 25' R-6 Height Limit T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) CURB : BLEEKER STREET 16 12 16 121/3 Height of 16/12 Historic Gable Roof ELEV - 119'-3 3/4" (V.I.F.) T.O. F.F. Main Lvl. (Victorian) ELEV - 101'-5" (V.I.F.) 16 12 5 5 5 5 5 5 1 2 2 2 2 53 3 3 6 HISTORIC RESTORATION KEY / DEMOLITION : AREAS SHADED TO BE REMOVED 1.RESTORE FRONT ENTRY (BLEEKER STREET) PORCH TO OPEN CONDITION PER HISTORICAL RECORD. RAILING AND ORNATE DETAILING, POSTS TO BE RESTORED / SIMPLIFIED TO ORIGINAL DETAILING CONDITIONS PER HISTORICAL IMAGING. REFER TO PROPOSED ELEVATIONS. 2.NON-HISTORIC WEST SIDE YARD PORCH & SECONDARY ENTRY / MUDROOM / TIE IN TO ENCLOSED BREEZEWAY / CONNECTOR TO BE REMOVED. WEST WALL HISTORIC WINDOW OPENINGS AND DORMER TO REMAIN AND BE RESTORED PER HISTORIC CONDITIONS. ALL NON-HOSTORIC DETAILING TO BE REMOVED ACCORDINGLY. 3.NON-HISTORIC 4/12 GABLE MASSING DIRECTLY ABUTTED TO THE SOUTH ELEVATION OF THE HISTORIC VICTORIAN TO BE REMOVED IN ITS ENTIRETY. PER HISTORICAL IMAGERY AND EXISTING IMAGING - DESIGN INTENT TO RE-ESTABLISH THE HISTORICAL 16/ 12 MASS AND FORM CONSISTENT WITH THE EXISTING HISTORICAL CONDITIONS "MIRRORED" E-W / N-S. DETAILING TO MATCH EXISTING HISTORICAL CONDITIONS. SOUTH WEST REAR CORNER OF VICTORIAN TO BE RE-ESTABLISHED PER PROPOSED ELEVATIONS AND PLANNING. 4.EAST ELEVATION MASSING DIRECTLY ABUTTED TO EXISTING VICTORIAN TO BE REMOVED. SOUTH EAST REAR ORIGINAL VICTORIAN CORNER TO BE RE-ESTABLISHED PER PROPOSED ELEVATIONS AND PLANNING. 5.EXISTING GARAGE AND SECONDARY 16/12 GABLE MASSING AREA OF THE EXISTING HOME TO BE REMOVED IN ITS ENTIRETY. PROPOSED NEW MASSING BRINGS ALL PROPOSED MASSING TO BE LEGALLY DEVELOPED WITHIN THE PROPERTY BOUNDARY. 6.PER HISTORICAL IMAGING, CHIMNEY HEIGHT + PROPORTION WAS LIKELY RECONSTRUCTED PER 1990'S ADDITIONS. PROPOSE TO RESTORE / RECONSTRUCT HISTORICAL VICTORIAN CHIMNEY TO MORE ACCURATE HISTORICAL DESIGN INTENT. RE A R Y A R D PR O P E R T Y L I N E 5' R E A R Y A R D SE T B A C K ( G A R A G E ) 10 ' R E A R Y A R D S E T B A C K (H A B I T A B L E ) 25' R-6 Height Limit 10 ' F R O N T Y A R D SE T B A C K PR O P E R T Y L I N E ED G E O F C U R B : BL E E K E R S T R E E T T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) 7896 7895.4 ALLEY ASPHALT 7895 7894 78947894 T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) CURB : BLEEKER STREET 16 12 16 12 T.O. F.F. Main Lvl. (Victorian) ELEV - 101'-5" (V.I.F.) 16 12 16 12 16 12 6 5 35 5 5 5 3 3 4 4 4 1 1 1 HPC-3.002 EXISTING ELEVATION/ SECTIONS - WEST ELEVATION (NEIGHBORING) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-3.002 2 HPC-3.002 EXISTING ELEVATION/ SECTIONS - EAST ELEVATION (SIDE ALLEY) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" EXISTING HPC JANUARY 2021 ELEVATIONS WE S T S I D E Y A R D PR O P E R T Y L I N E 5' S I D E Y A R D S E T B A C K 5' S I D E Y A R D S E T B A C K EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) EA S T S I D E Y A R D AL L E Y S T A R T T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) 7894 25' R-6 Height Limit 1/3 Height of 16/12 Historic Gable Roof ELEV - 119'-3 3/4" (V.I.F.) HISTORIC RESTORATION KEY / DEMOLITION : AREAS SHADED TO BE REMOVED 1.RESTORE FRONT ENTRY (BLEEKER STREET) PORCH TO OPEN CONDITION PER HISTORICAL RECORD. RAILING AND ORNATE DETAILING, POSTS TO BE RESTORED / SIMPLIFIED TO ORIGINAL DETAILING CONDITIONS PER HISTORICAL IMAGING. REFER TO PROPOSED ELEVATIONS. 2.NON-HISTORIC WEST SIDE YARD PORCH & SECONDARY ENTRY / MUDROOM / TIE IN TO ENCLOSED BREEZEWAY / CONNECTOR TO BE REMOVED. WEST WALL HISTORIC WINDOW OPENINGS AND DORMER TO REMAIN AND BE RESTORED PER HISTORIC CONDITIONS. ALL NON-HOSTORIC DETAILING TO BE REMOVED ACCORDINGLY. 3.NON-HISTORIC 4/12 GABLE MASSING DIRECTLY ABUTTED TO THE SOUTH ELEVATION OF THE HISTORIC VICTORIAN TO BE REMOVED IN ITS ENTIRETY. PER HISTORICAL IMAGERY AND EXISTING IMAGING - DESIGN INTENT TO RE-ESTABLISH THE HISTORICAL 16/ 12 MASS AND FORM CONSISTENT WITH THE EXISTING HISTORICAL CONDITIONS "MIRRORED" E-W / N-S. DETAILING TO MATCH EXISTING HISTORICAL CONDITIONS. SOUTH WEST REAR CORNER OF VICTORIAN TO BE RE-ESTABLISHED PER PROPOSED ELEVATIONS AND PLANNING. 4.EAST ELEVATION MASSING DIRECTLY ABUTTED TO EXISTING VICTORIAN TO BE REMOVED. SOUTH EAST REAR ORIGINAL VICTORIAN CORNER TO BE RE-ESTABLISHED PER PROPOSED ELEVATIONS AND PLANNING. 5.EXISTING GARAGE AND SECONDARY 16/12 GABLE MASSING AREA OF THE EXISTING HOME TO BE REMOVED IN ITS ENTIRETY. PROPOSED NEW MASSING BRINGS ALL PROPOSED MASSING TO BE LEGALLY DEVELOPED WITHIN THE PROPERTY BOUNDARY. 6.PER HISTORICAL IMAGING, CHIMNEY HEIGHT + PROPORTION WAS LIKELY RECONSTRUCTED PER 1990'S ADDITIONS. PROPOSE TO RESTORE / RECONSTRUCT HISTORICAL VICTORIAN CHIMNEY TO MORE ACCURATE HISTORICAL DESIGN INTENT. 6 T.O. F.F. Main Lvl. (Victorian) ELEV - 101'-5" (V.I.F.) 5 3 5 3 5 3 3 5 2 5 2 2 4 4 4 4 4 5 16 12 16 12 4 12 4 12 8 12 Existing Massing Behind South Alley Elevation WE S T S I D E Y A R D PR O P E R T Y L I N E 5' S I D E Y A R D S E T B A C K 25' R-6 Height Limit 5' S I D E Y A R D S E T B A C K EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) EA S T S I D E Y A R D AL L E Y S T A R T 5 5 5 5 2 12 4 12 16 12 1 HPC-3.003 EXISTING ELEVATION/ SECTIONS - SOUTH ELEVATION (INTERIOR : HISTORIC VICTORIAN) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-3.003 2 HPC-3.003 EXISTING ELEVATION/ SECTIONS - SOUTH ELEVATION (REAR ALLEY) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" EXISTING HPC JANUARY 2021 ELEVATIONS EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) WE S T S I D E Y A R D PR O P E R T Y L I N E 5' S I D E Y A R D S E T B A C K 5' S I D E Y A R D S E T B A C K 16 12 16 12 EA S T S I D E Y A R D AL L E Y S T A R T 25' R-6 Height Limit T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. Plwd. Main Level (13" lower than existing floor) ELEV - 100'-0" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) 7894 T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. F.F. Main Lvl. Entry (Victorian) ELEV - 101'-5" (V.I.F.) T.O. Conc. Lower Level ( TBD) ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) T.O. Conc. Grotto ( TBD) ELEV - 86'-3 1/4" (V.I.F.) (TBD) ACH 101'-5" = 7895.5 ELEV (V.I.F.)15' Maximum. Subgrade Line of F.F. 1/3 Height of 16/12 Historic Gable Roof ELEV - 119'-3 3/4" (V.I.F.) EA S T S I D E Y A R D AL L E Y S T A R T EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) 5' S I D E Y A R D S E T B A C K 5' S I D E Y A R D S E T B A C K WE S T S I D E Y A R D PR O P E R T Y L I N E 7894 T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. Plwd. Main Level (13" lower than existing floor) ELEV - 100'-0" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. F.F. Main Lvl. Entry (Victorian) ELEV - 101'-5" (V.I.F.) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) 25' R-6 Height Limit T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) T.O. Conc. Lower Level ( TBD) ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) T.O. Conc. Grotto ( TBD) ELEV - 86'-3 1/4" (V.I.F.) (TBD) ACH 101'-5" = 7895.5 ELEV (V.I.F.)15' Maximum. Subgrade Line of F.F. Historic Victorian Massing 1 HPC-3.004 PROPOSED ELEVATION/ SECTIONS - NORTH ELEVATION (121 BLEEKER) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-3.004 2 HPC-3.004 PROPOSED ELEVATION/ SECTIONS - NORTH ELEVATION (INTERIOR : CONNECTOR / ADDITION) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" PROPOSED HPC JANUARY 2021 ELEVATIONS 7894 PR O P E R T Y L I N E ED G E O F C U R B : BL E E K E R S T R E E T 7894 7895.4 ALLEY ASPHALT RE A R Y A R D PR O P E R T Y L I N E 5' R E A R Y A R D SE T B A C K ( G A R A G E ) 10 ' R E A R Y A R D S E T B A C K (H A B I T A B L E ) 10 ' F R O N T Y A R D SE T B A C K 7895 7896 7894 25' R-6 Height Limit 1/3 Height of 12/12 Gable Roof ELEV - 123'-9 1/4" (V.I.F.) G E 15' Maximum. Subgrade Line of F.F. 25' R-6 Height Limit T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. Plwd. Main Level (13" lower than existing floor) ELEV - 100'-0" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. F.F. Main Lvl. Entry (Victorian) ELEV - 101'-5" (V.I.F.) T.O. Conc. Lower Level ( TBD) ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) CURB : BLEEKER STREET T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) T.O. Plwd. Main Level ELEV - 100'-0" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) T.O. Conc. Lower Level ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) T.O. Plwd. Garage Level ELEV - 101'-0" (V.I.F.) T.O. F.F. Garage Level ELEV - 101'-5" (V.I.F.) ELEV - 110'-5 1/4" (V.I.F.) T.O. Plate Main Level/ Garage (Not Lower - TBD) T.O. Plwd. Main Master Deck Over Garage ELEV - 111'-5 1/4" (V.I.F.) T.O. Plwd. Upper Level/ Master Suite ELEV - 111'-10" (V.I.F.) T.O. F.F. Upper/ Master Suite Level ELEV - 112'-1" (V.I.F.) T.O. Wood Master Deck Railing/ Wall ELEV - 115'-8" (V.I.F.) T.O. Plate / Spring Point 1/12 Shed Dormer (Low) ELEV - 120'-1" (V.I.F.) T.O. Plate Master Bed Alley Bump Up ELEV - 121'-2" (V.I.F.) ELEV - 129'-9 3/8" (V.I.F.) ELEV - 119'-7" (V.I.F.) T.O. Plate/ Spring Point Master Bed 12/12 Gable T.O. Ridge Height of 12/12 Gable Roof 16 12 16 12 12 12 12 1 ACH 101'-5" = 7895.5 ELEV (V.I.F.) 1/3 Height of 16/12 Historic Gable Roof ELEV - 119'-3 3/4" (V.I.F.) HC E L E C T R I C GA S RE A R Y A R D PR O P E R T Y L I N E 5' R E A R Y A R D SE T B A C K ( G A R A G E ) 10 ' R E A R Y A R D S E T B A C K (H A B I T A B L E ) 25' R-6 Height Limit 10 ' F R O N T Y A R D SE T B A C K PR O P E R T Y L I N E ED G E O F C U R B : BL E E K E R S T R E E T T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. Plwd. Main Level (13" lower than existing floor) ELEV - 100'-0" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) 7896 7895.4 ALLEY ASPHALT 7895 7894 78947894 15' Maximum. Subgrade Line of F.F. T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. F.F. Main Lvl. Entry (Victorian) ELEV - 101'-5" (V.I.F.) T.O. Conc. Lower Level ( TBD) ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) CURB : BLEEKER STREET T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) 16 12 16 12 12 12 12 1 1/3 Height of 12/12 Gable Roof ELEV - 123'-9 1/4" (V.I.F.) T.O. Plwd. Main Level ELEV - 100'-0" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) T.O. Conc. Lower Level ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) T.O. Plwd. Garage Level ELEV - 101'-0" (V.I.F.) T.O. F.F. Garage Level ELEV - 101'-5" (V.I.F.) ELEV - 110'-5 1/4" (V.I.F.) T.O. Plate Main Level/ Garage (Not Lower - TBD) T.O. Plwd. Main Master Deck Over Garage ELEV - 111'-5 1/4" (V.I.F.) T.O. Plwd. Upper Level/ Master Suite ELEV - 111'-10" (V.I.F.) T.O. F.F. Upper/ Master Suite Level ELEV - 112'-1" (V.I.F.) T.O. Wood Master Deck Railing/ Wall ELEV - 115'-8" (V.I.F.) T.O. Plate / Spring Point 1/12 Shed Dormer (Low) ELEV - 120'-1" (V.I.F.) T.O. Plate Master Bed Alley Bump Up ELEV - 121'-2" (V.I.F.) ELEV - 129'-9 3/8" (V.I.F.) ELEV - 119'-7" (V.I.F.) T.O. Plate/ Spring Point Master Bed 12/12 Gable T.O. Ridge Height of 12/12 Gable Roof T.O. Conc. Grotto ( TBD) ELEV - 86'-3 1/4" (V.I.F.) (TBD) ACH 101'-5" = 7895.5 ELEV (V.I.F.) 16 12 1 HPC-3.005 PROPOSED ELEVATION/ SECTIONS - WEST ELEVATION (NEIGHBORING) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-3.005 2 HPC-3.005 PROPOSED ELEVATION/ SECTIONS - EAST ELEVATION (SIDE ALLEY) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" PROPOSED HPC JANUARY 2021 ELEVATIONS WE S T S I D E Y A R D PR O P E R T Y L I N E 5' S I D E Y A R D S E T B A C K 5' S I D E Y A R D S E T B A C K EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) EA S T S I D E Y A R D AL L E Y S T A R T T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. Plwd. Main Level (13" lower than existing floor) ELEV - 100'-0" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. F.F. Main Lvl. Entry (Victorian) ELEV - 101'-5" (V.I.F.) T.O. Conc. Lower Level ( TBD) ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) T.O. Conc. Grotto ( TBD) ELEV - 86'-3 1/4" (V.I.F.) (TBD) ACH 101'-5" = 7895.5 ELEV (V.I.F.) 7894 25' R-6 Height Limit 15' Maximum. Subgrade Line of F.F. Proposed Massing Behind 1/3 Height of 16/12 Historic Gable Roof ELEV - 119'-3 3/4" (V.I.F.) WE S T S I D E Y A R D PR O P E R T Y L I N E 5' S I D E Y A R D S E T B A C K PV-1 34 PANEL PV ROOF SYSTEM SITUATED @ 45 DEGREES PV-2 PV-18 PV-19 PV-20 PV-3 PV-4 PV-21 PV-5 PV-22 PV-23 PV-6 PV-7 PV-24 PV-25 PV-8 PV-9 PV-26 PV-10 PV-27 PV-28 PV-11 PV-12 PV-29 PV-30 PV-31 PV-13 PV-14 PV-15 PV-32 PV-16 PV-33 PV-34 PV-17 T.O. Plwd. Upper (Hold Ex. Plwd. Ht.) ELEV - 111'-10" (V.I.F.) T.O. Plwd. Main Level (13" lower than existing floor) ELEV - 100'-0" (V.I.F.) T.O. F.F. Upper Level Victorian ELEV - 112'-1" (V.I.F.) T.O. F.F. Main Level ELEV - 100'-3" (V.I.F.) T.O. Plate Main Level (Not Lower - TBD) ELEV - 110'-5 1/4" (V.I.F.) T.O. 16/12 Ridge(Secondary) Cross Gable ELEV - 122'-11" (V.I.F.) T.O. F.F. Main Lvl. Entry (Victorian) ELEV - 101'-5" (V.I.F.) T.O. Masonry Chimney (TBD) ELEV - 135'-2 1/8" (V.I.F.) T.O. Upper Level 16/12 Spring Point ELEV - 113'-6" (V.I.F.) T.O. 16/12 N-S Ridge Primary Gable ELEV - 130'-10 1/8" (V.I.F.) T.O. 16/12 E-W Dormer Ridges ELEV - 125'-7 1/4" (V.I.F.) 25' R-6 Height Limit T.O. Ceiling Lower (Subgrade) Level (Not Lower - TBD) ELEV - 96'-9 1/4" (V.I.F.) T.O. Conc. Lower Level ( TBD) ELEV - 86'-7 1/4" (V.I.F.) (TBD) T.O. Conc. Light Well (2'-6" above Proposed F.F.) ELEV - 89'-1 1/4" (V.I.F.) T.O. Conc. Grotto ( TBD) ELEV - 86'-3 1/4" (V.I.F.) (TBD) ACH 101'-5" = 7895.5 ELEV (V.I.F.)15' Maximum. Subgrade Line of F.F. T.O. 16/12 E-W Dormer Spring Points ELEV - 121'-5" (V.I.F.) 5' S I D E Y A R D S E T B A C K EA S T S I D E Y A R D PR O P E R T Y L I N E (S I D E A L L E Y ) EA S T S I D E Y A R D AL L E Y S T A R T 1 HPC-3.006 PROPOSED ELEVATION/ SECTIONS - SOUTH ELEVATION (INTERIOR : HISTORIC VICTORIAN) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" ISSUANCE SEAL DRAWING NO: DRAWING TITLE: PROJECT # SCALE DATE 121- BLEEKER 01 HPC / CONCEPTUAL c 1 F R I D A Y D E S I G N , L L C 2 0 2 0 12 1 W E S T B L E E K E R RE S I D E N C E "T A N G L E D U P I N B L U E " 12 1 W e s t B l e e k e r S t r e e t , A s p e n , C O 8 1 6 1 1 Owners: 121 W Bleeker LLC 121 West Bleeker Street Aspen, CO 81611 SURVEY ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com PROJECT DESIGNER / CITY REPRESENTATIVE 1 Friday Design PO BOX 7928 Aspen, Colorado 81612 T: 970.309.0695 www.1friday.com STRUCTURAL ENGINEER James Jackson Romeo, P.E. Structural Design Consultant, LLC 3901 Mountain Drive #11 Glenwood Springs, CO 81601 T: 970.945.4742 www.jjrstructural.com d e r e k m s k a l k o GENERAL CONTRACTOR Kaegebein Fine Homebuilding PO BOX 1570 Carbondale, Colorado 81623 T: 970.510.5797 www.kfhomebuilding.com CIVIL ENGINEER Boundaries Unlimited Inc. 923 Cooper Avenue, Suite 201 Glenwood Springs, CO 81601 T: 970.945.5252 www.bu-inc.com OWNERSHIP HPC-3.006 2 HPC-3.006 PROPOSED ELEVATION/ SECTIONS - SOUTH ELEVATION (REAR ALLEY) :: 121 WEST BLEEKER SCALE : 3/16" = 1'-0" PROPOSED HPC JANUARY 2021 ELEVATIONS