Loading...
HomeMy WebLinkAboutMemo.121WBleeker.20210608 Page 1 of 4 427 Rio Grande Place, Aspen, CO 81611-1975 | P: 970.920.5197 | aspen.gov Memorandum TO: Aspen Historic Preservation Commission FROM: Sarah Yoon, Historic Preservation Planner THROUGH: Natalie Feinberg Lopez, Historic Preservation Officer MEETING DATE: June 8, 2022 RE: 121 West Bleeker Street – Final Major Development and Floor Area Bonus, PUBLIC HEARING APPLICANT /OWNER: 121 W Bleeker LLC REPRESENTATIVE: 1 Friday Design LOCATION: Street Address: 121 W. Bleeker Street Legal Description: The East ½ of Lot C, All of Lot D, and the West ½ of Lot E, Block 58, City and Townsite of Aspen, Colorado Parcel Identification Number: PID# 2735-124-39-003 CURRENT ZONING & USE R-6 (Moderate-Density Residential); Single-family home PROPOSED ZONING & USE: No change SUMMARY: On May 26, 2021, the applicant received Conceptual Major Development approval to demolish all non-historic alterations and additions, to relocate the historic home on a new basement, and to construct a new addition to the rear of the property. Setback variations and a 205 s.f. floor area bonus was granted to the design with a unanimous vote of 7-0 during the second round of design review. As a historically designated landmark, the project is exempt from Residential Design Standards Review (RDS). STAFF RECOMMENDATION: Staff recommends approval with conditions listed on page 4 of this memo. Site Locator Map – 121 W. Bleeker Street 121 Page 2 of 4 427 Rio Grande Place, Aspen, CO 81611-1975 | P: 970.920.5197 | aspen.gov BACKGROUND: 121 W. Bleeker is a 6,000 s.f. lot in the R-6 residential zone district. This property contains a Victorian era home that was historically designated via Ordinance 34, Series of 1992. Building permit records show various alterations were made to the historic resource that include the addition of large dormers and a new porch to the west elevation. Setback variances for these extensions were granted by the Board of Adjustment in the early 1990s. Although the Sanborn Map indicates the home is in its original location, numerous alterations have resulted in the loss of historic building fabric. REQUEST OF HISTORIC PRESERVATION COMMISSION (HPC) The Applicant is requesting the following land use approvals: • Major Development (Section 26.415.070.D) to demolish non-historic alterations and additions made to the historic home and construct a new addition to the rear of the property. • Floor Area Bonus (Section 26.415.110.F) to revise the floor area bonus request to 250 square feet of floor area to build the approved design. This project was called up by City Council and presented on July 13, 2021. City Council upheld HPC’s decision and approvals. PROJECT SUMMARY: The applicant received Conceptual Major Development approval to fully restore the historic resource and construct a new addition to the rear of the property. The historic home will be temporarily relocated on-site during the excavation of the basement, then placed back in its historic location on the lot. The height of the resource will be maintained. Setback variations for new mechanical equipment and a 205 s.f. floor area bonus was granted for the approved design. The Final Major Development review focuses on landscape design, selection of materials and fenestration, and the final lighting plan. The applicant presents a more refined landscape design with a landscape architect on board the project and a request to correct the floor area bonus from 205 s.f. to 250 s.f. to construct the approved design without change. STAFF COMMENTS: The existing landscape features and plantings currently expands into the right-of-way. Two large cottonwood trees and a historic metal fence are located at the front of the property. Existing privacy fences are to remain in place without any further alterations. Staff finds the proposed pathways do not meet the Design Guidelines and requires a restudy with input from the Parks Department about work in the driplines of trees. The perennial plantings, particularly in the right- of-way, should be reduced, and the retention of the existing metal fence along the front of the Figure 1 – 121 W. Bleeker, 2000 Page 3 of 4 427 Rio Grande Place, Aspen, CO 81611-1975 | P: 970.920.5197 | aspen.gov property should be further discussed by HPC. Overall, staff supports the approval for Final Major Development and find the listed items above may be finalized through the staff & monitor process. Staff recommends HPC review the following topics: 1. Landscape and Lighting Plans: The proposed landscape design increases the use of perennial plantings around the front of the property with limited areas of sod. Sod would not be feasible in certain areas due to the large cottonwood trees; however, in areas around the resource, staff finds it to be the more historically appropriate setting for the historic resource. The planting beds and shrubs in the right-of-way may not be permitted by the Parks Department because they interfere with the established cottonwoods and implies a privatization of land. Staff recommends the reduction of perennial plantings and working with the Parks Department for their feedback on appropriate landscaping in the right-of-way. The landscape plan also shows a curved concrete walkway leading up to the front porch, similar to what is there currently. Staff supports the grey concrete material for the main walkway, but the Design Guidelines recommend a perpendicular path from the street to the front entry. A meandering path is only allowed at points where trees need to be avoided (Design Guidelines 1.6). In addition, there are two secondary paths that connect the front walkway to the hardscaped areas behind the historic resource. Staff recommends these secondary paths be reduced in scale and the main walkway be straightened out to the best extent possible. All walking surfaces must be compliant with necessary dripline protection that the Parks Department may require. A drywell is located at the front of the property along the east side. As the applicant team continues to work with the relevant City Departments towards a finalized storm water mitigation plan, staff recommends all features have minimal visual impact (Design Guideline 1.8). The lighting plans include code compliant fixtures and no landscape lighting. There are two recessed can lights that are proposed for the historic porch. Staff recommends one recessed light in this area to provide a level of illumination that is minimal (Design Guideline 12.3). Lastly, there is an existing wrought iron fence on the property that is not original to the site. In circumstances where there is no historical evidence of an ornate wrought iron fence, the design guidelines encourage a modest wooden fence with a transparent quality that allows for clear views of the resource from the street. Retaining the existing wrought iron fence may create a false sense of history that would be inaccurate (Design Guideline 1.18). HPC discussion regarding the matter is requested. 2. New Addition – Materials and Fenestration: The new addition is recessed and sited behind the historic resource. Although the connection point between old and new construction is wider than the typical connecting element, it was determined during the conceptual hearing that this would be appropriate for this property since no historic material will be lost. The new addition Page 4 of 4 427 Rio Grande Place, Aspen, CO 81611-1975 | P: 970.920.5197 | aspen.gov uses different applications of wood siding to relate to the historic resource. The fenestration on the new addition is a departure from the historic resource but maintains a glazing to wall ratio that is visually compatible. If there is a stone foundation at the base of the historic resource, this will need to be maintained, otherwise an exposed concrete or painted metal flashing would be appropriate (Design Guideline 9.5). Information about the foundation and exterior conditions of the historic resource will need to be provided as part of the preservation plan along with the proposed treatments for restoration. 3. Floor Area Bonus Updates: A calculation error was discovered for floor area that needs to be corrected in order for the approved conceptual design to be built. The applicant requests for a revised amount of 250 s.f. to resolve this error. It is important to note that this request will not change the mass and scale of the approved addition in any way. Staff supports the updated floor area bonus request. RECOMMENDATION: Staff recommends the Historic Preservation Commission (HPC) approve this application with the following conditions: 1. The landscape plan to be finalized by staff & monitor with regard to reducing plantings, particularly in the right-of-way, and restudying the proposed walkways to meet Design Guideline 1.6. Final plan to be reviewed and approved prior to building permit submission. 2. Submit a preservation plan that includes documentation of existing conditions and proposed treatments for restoration for staff & monitor level approval, prior to building permit submission. 3. Continue working with relevant City Departments regarding comments related to the transformer, new water line and the stormwater mitigation plan. Minimize visual impact of stormwater features in the foreground of the historic resource and review finalized stormwater plan with staff & monitor, prior to building permit submission. 4. Reduce porch lighting to one fixture and provide location of fires department connection (FDC) hook-up and strobe to staff & monitor prior to permit submission. The FDC is to be sensitively located and the strobe is to be a white casing. 5. The approved conceptual design with no changes is granted a revised floor area bonus of 250 s.f. All calculations will be confirmed during building permit review. Bonus floor area not used for this project will be forfeited and must be earned through a future request. ATTACHMENTS: Resolution #____, Series of 2022 Exhibit A.1 – Historic Preservation Design Guidelines Criteria / Staff Findings Exhibit A.2 – Floor Area Bonus / Staff Findings Exhibit B – HPC Resolution #10, Series of 2021 and Meeting Minutes, May 26, 2021 Exhibit C – Application