HomeMy WebLinkAboutFenestration Changes.134 E Bleeker St.20220210T.O.F.F. @ MAIN LEVEL
100' -0"
(E) ROOF
125' -2 1/2"
E C B A
(E/P) B.O. HEADER UL ADDITION
118' -4 1/2"
F
T.O.F.F. @ UPPER LEVEL
109' -7"20
'
-
1
"
RO
O
F
H
E
I
G
H
T
C
A
L
C
.
CC BBEED
T.O.F.F. @ MAIN LEVEL
100' -0"
T.O.F.F. @ BASEMENT
87' -0"
E C B A
T.O. ROOF
125' -2 1/2"
F
21
'
-
1
1
"
T.O.F.F. @ UPPER LEVEL
109' -7"RO
O
F
H
E
I
G
H
T
C
A
L
C
.
0'
-
9
7
/
8
"
T.O.F.F AT CRAWLSPACE
80' -6"
ARCHITECTURAL ASPHALT SHINGLES
TO REPLACE EXISTING, TYP
EXISTING SIDING TO BE REPAINTED
(P) GARAGE DOOR TO MATCH
EXISTING HORIZONTAL SIDING (E) SIDING TO BE REPAINTED, TYP.
25' BUILDING HEIGHT RESTRICTION CALCULATED FROM MOST RESTRICTIVE GRADE
EXISTING PENETRATION; TO BE USED FOR 8" ROUND PLUMBING VENT
HISTORIC PENETRATION; NOT IN USE
EXISTING PENETRATION TO BE
USED FOR 8" EXHAUST
EXISTING PENETRATION;
TO BE USED FOR 6"
ROUND PLUMBING VENT
EXISTING
W19
EXISTING
W47
LEAD COATED
COPPER GUTTERS
AND DOWNSPOUTS
NEW
E02
REPAIR AND REPAINT; EXISTING RAIL TO REMAIN
ADD STEEL LOWER BAR TO COMPLY WITH IRC R312.1.3
EXISTING BALCONY FRAMING TO REMAIN
SNOW CLIPS
CC BBEE
2% SLOPE AWAY 2% SLOPE AWAY
GRAVEL SURFACING RE: LANDSCAPE
SUBGRADE LEVEL BEYOND
MATERIAL BUILDUP REF:
LANDSCAPE
D
T.O.F.F. @ MAIN LEVEL
100' -0"
MAIN LEVEL CEILING @ DINING
109' -6"
(E) ROOF
125' -2 1/2"
8 7 6 5 4 3 2 1
(E/P) B.O. HEADER UL ADDITION
118' -4 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
T.O.F.F. UPPER FLOOR @ VICTORIAN
110' -8 1/2"
MAIN LEVEL CEILING @ LIVING
108' -7 3/4"
1A1B4B
T.O.F.F. @ MAIN LEVEL
100' -0"
MAIN LEVEL CEILING @ DINING
109' -6"
T.O.F.F. @ BASEMENT
87' -0"
8 7 6 5 4 3 2 1
T.O. ROOF
125' -2 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
T.O.F.F. UPPER FLOOR @ VICTORIAN
110' -8 1/2"
3'
-
6
7
/
8
"
0'
-
1
1
1
/
4
"
T.O.F.F AT CRAWLSPACE
80' -6"
T.O.F.F AT CRAWLSPACE
80' -6"
ARCHITECTURAL ASPHALT SHINGLES
TO REPLACE EXISTING, TYP
(E) SIDING TO BE REPAINTED, TYP.(P) SIDING TO MATCH (E) TYP.
EXISTING SIDING TO BE REPAINTED
NEW
W20
NEW
W19
25' BUILDING HEIGHT RESTRICTION CALCULATED FROM MOST RESTRICTIVE GRADE
MAIN LEVEL CEILING @ LIVING
108' -7 3/4"
HISTORIC CHIMNEY TO REMAIN;
NOT IN USE
EXISTING PLUMBING
FLUE VENT; TO BE USED
W48
EXISTING
135
NEW
W14
EXISTING
W18
EXISTING
W96
EXISTING
W10
REPLACE
W53
LEAD COATED COPPER
GUTTERS AND DOWNSPOUTS
LOCATION FOR ELECTRICAL
UTILITIES; TO BE PAINTED
TO MATCH SIDING
W51
EXISTING
W27
UTILITY
CT
CLOSET
FUSED
SERVICE
DISCONNECT
MAIN
ELECTRICAL
PANEL
GAS METER
1A1B4B
REPAIR AND REPAINT. EXISTING RAIL TO REMAIN
ADD STEEL LOWER BAR TO COMPLY WITH IRC R312.1.3
EXISTING BALCONY FRAMING TO REMAIN
REPAIR
SNOW CLIPS
EXISTING DECORATIVE ELEMENT TO
REPAIR AND REMAIN
(4) MECH UNITS
2'
-
4
"
SNOW CLIPS
MATERIAL BUILD UP
RE: LANDSCAPE
SUBGRADE LEVEL BEYOND
MATERIAL BUILD UP
RE: LANDSCAPE
_______
A.6.05
1
Sim
3' - 0"
NEW
W61
NEW
W60
MATCH EXISTING
HISTORIC SIDING
NOTES:
1. BUILDING HEIGHT, FOOTPRINT AND MASSING MUST NOT CHANGE
FOLLOWING TEMPORARY RELOCATION OF THE EXISTING ADDITION.
2. PROPOSED SNOW CLIP TO BE PLACED PER MANUFACTURER
SPECIFICATIONS SUCH THAT CONFIGURATION TO BE MINIMAL NEEDED
AND SHALL NOT RUN UP ALL THE WAY TO THE ROOF EDGE PER CITY OF
ASPEN HISTORIC PRESERVATION.
ALIGN SILL
T.O.F.F. @ MAIN LEVEL
100' -0"
MAIN LEVEL CEILING @ DINING
109' -6"
(E) ROOF
125' -2 1/2"
ECBA
(E/P) B.O. HEADER UL ADDITION
118' -4 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
F
20
'
-
1
"
T.O.F.F. UPPER FLOOR @ VICTORIAN
110' -8 1/2"
RO
O
F
H
E
I
G
H
T
C
A
L
C
.
CCBB EED
T.O.F.F. @ MAIN LEVEL
100' -0"
T.O.F.F. @ BASEMENT
87' -0"
ECBA
T.O. ROOF
125' -2 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
F
15
'
-
8
3
/
8
"
T.O.F.F. UPPER FLOOR @ VICTORIAN
110' -8 1/2"
RO
O
F
H
E
I
G
H
T
C
A
L
C
.
3'
-
6
"
0'
-
9
7
/
8
"
T.O.F.F AT CRAWLSPACE
80' -6"
ARCHITECTURAL ASPHALT SHINGLES
TO REPLACE EXISTING, TYP
EXISTING SIDING TO BE REPAINTED
25' BUILDING HEIGHT RESTRICTION CALCULATED FROM MOST RESTRICTIVE GRADE
HISTORIC CHIMNEY TO
REMAIN; TO BE USED AS
PLUMBING VENT HISTORIC CHIMNEY TO
REMAIN; NOT IN USE
HISTORIC PENETRATION;
NOT IN USE
EXISTING
W38
EXISTING
W32
EXISTING
W33
EXISTING
W30
EXISTING
W31
NEW
W37
LEAD COATED COPPER GUTTERS
AND DOWNSPOUTS
REPLACE
W52
W50
EXISTING
E06
REPAIR
CCBB EE
2% SLOPE AWAY 2% SLOPE AWAY
SNOW CLIPS
EXISTING DECK TO REPAIR
AND REMAIN PER HPC
MATERIAL BUILD UP RE:
LANDSCAPE
MATERIAL BUILD UP RE:
LANDSCAPE
_______
A.6.05
1
Sim
REPLACE
W13
REPLACE
E03
D
HISTORIC ENTRY TO REPAIR
AND REMAIN PER HPC
NOTES:
1. BUILDING HEIGHT, FOOTPRINT AND MASSING MUST NOT CHANGE FOLLOWING
TEMPORARY RELOCATION OF THE EXISTING ADDITION.
2. PROPOSED SNOW CLIP TO BE PLACED PER MANUFACTURER SPECIFICATIONS
SUCH THAT CONFIGURATION TO BE MINIMAL NEEDED AND SHALL NOT RUN UP ALL
THE WAY TO THE ROOF EDGE PER CITY OF ASPEN HISTORIC PRESERVATION.
3' - 1"
T.O.F.F. @ MAIN LEVEL
100' -0"
(E) ROOF
125' -2 1/2"
ECB
T.O. ROOF
125' -2 1/2"
F
T.O.F.F. @ UPPER LEVEL
109' -7"
(P) GARAGE CEILING
108' -2 1/8"
CCBB EED
T.O.F.F. @ MAIN LEVEL
100' -0"
(E) ROOF
125' -2 1/2"
ECBA
T.O. ROOF
125' -2 1/2"
F
T.O.F.F. @ UPPER LEVEL
109' -7"
(P) GARAGE CEILING
108' -2 1/8"
CCBB EED
EXISTING
W46
EXISTING
W34 NEW
E05
NEW
E09
NEW
W37EXISTING SIDING TO BE REPAINTED
HISTORIC CHIMNEY TO
REMAIN; NOT IN USE
LEAD COATED COPPER GUTTERS
AND DOWNSPOUTS
NEW GLAZING ONLY; OPENING
TO REMAIN AS EXISTING
T.O.F.F. @ MAIN LEVEL
100' -0"
(E) ROOF
125' -2 1/2"
87654321
T.O.F.F. @ UPPER LEVEL ADDITION
109' -10 1/4"
(E/P) B.O. HEADER UL ADDITION
118' -4 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
T.O.F.F. @ UPPER LEVEL
109' -7"
(P) GARAGE CEILING
108' -2 1/8"
9'
-
7
1
/
8
"
10
'
-
7
1
/
8
"
1A 1B 4B
T.O.F.F. @ MAIN LEVEL
100' -0"
T.O.F.F. @ BASEMENT
87' -0"
87654321
T.O.F.F. @ UPPER LEVEL ADDITION
109' -10 1/4"
T.O. ROOF
125' -2 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
T.O.F.F. @ UPPER LEVEL
109' -7"
3'
-
6
7
/
8
"
0'
-
1
1
1
/
4
"
T.O.F.F AT CRAWLSPACE
80' -6"
ARCHITECTURAL ASPHALT SHINGLES
TO REPLACE EXISTING, TYP
(E) PORCH FRAMING
TO REMAIN; RAILING
TO BE REPLACED
EXISTING SIDING TO BE REPAINTED
(E) SIDING TO BE REPAINTED, TYP.NEW
W12
NEW
W11
25' BUILDING
HEIGHT
RESTRICTION
CALCULATED FROM
MOST RESTRICTIVE
GRADE
(P) GARAGE CEILING
108' -2 1/8"
HISTORIC PENETRATION;
NOT IN USE
HISTORIC PENETRATION;
NOT IN USE
EXISTING PENETRATION;
TO BE USED FOR 6"
ROUND PLUMBING VENT
EXISTING CHIMNEY
TO REMAIN; TO BE
USED FOR 6" VENT
HISTORIC PENETRATION;
NOT IN USE
HISTORIC CHIMNEY TO
REMAIN; TO BE USED
AS PLUMBING VENT
EXISTING
W28
EXISTING
W29
EXISTING
W45
EXISTING
W24
EXISTING
W40
NEW
E01
EXISTING
W48
LEAD COATED
COPPER GUTTERS
NEW
W23
NEW
E12
NEW
W22
REPLACE
W54
NEW
W44
NEW
W43
1A 1B 4B
SNOW CLIPS
2% SLOPE AWAY2% SLOPE AWAY
EXISTING DECORATIVE ELEMENT TO
REPAIR AND REMAIN
EXISTING DECK TO REPAIR
AND REMAIN PER HPC
MATERIAL BUILD UP RE:
LANDSCAPE
SNOW CLIPS
_______
A.6.05
1
Sim
NOTES:
1. BUILDING HEIGHT, FOOTPRINT AND MASSING MUST NOT CHANGE
FOLLOWING TEMPORARY RELOCATION OF THE EXISTING ADDITION.
2. PROPOSED SNOW CLIP TO BE PLACED PER MANUFACTURER
SPECIFICATIONS SUCH THAT CONFIGURATION TO BE MINIMAL NEEDED
AND SHALL NOT RUN UP ALL THE WAY TO THE ROOF EDGE PER CITY
OF ASPEN HISTORIC PRESERVATION.
SHED ROOF
SCALE
:
1/4" = 1'-0"A.3.03
1 EXISTING EAST ELEVATION
SCALE
:
1/4" = 1'-0"A.3.03
2 PROPOSED EAST ELEVATION