HomeMy WebLinkAboutFenestration Changes.134 E Bleeker St.20220506T.O.F.F. @ MAIN LEVEL 100' -0" MAIN LEVEL CEILING @ DINING 109' -6" (E) ROOF 125' -2 1/2" 8 7 6 5 4 3 2 1 (E/P) B.O. HEADER UL ADDITION 118' -4 1/2" T.O.F.F. @ MAIN VICTORIAN 101' -0" T.O.F.F. UPPER FLOOR @ VICTORIAN 110' -8 1/2" MAIN LEVEL CEILING @ LIVING 108' -7 3/4" 1A1B4B T.O.F.F. @ MAIN LEVEL 100' -0" MAIN LEVEL CEILING @ DINING 109' -6" T.O.F.F. @ BASEMENT 87' -0" 8 7 6 5 4 3 2 1 T.O. ROOF 125' -2 1/2" T.O.F.F. @ MAIN VICTORIAN 101' -0" T.O.F.F. UPPER FLOOR @ VICTORIAN 110' -8 1/2" 3' - 6 7 / 8 " 0' - 1 1 1 / 4 " T.O.F.F AT CRAWLSPACE 80' -6" T.O.F.F AT CRAWLSPACE 80' -6" ARCHITECTURAL ASPHALT SHINGLES TO REPLACE EXISTING, TYP (E) SIDING TO BE REPAINTED, TYP.(P) SIDING TO MATCH (E) TYP. EXISTING SIDING TO BE REPAINTED NEW W57 NEW W56 25' BUILDING HEIGHT RESTRICTION CALCULATED FROM MOST RESTRICTIVE GRADE MAIN LEVEL CEILING @ LIVING 108' -7 3/4" HISTORIC CHIMNEY TO REMAIN; NOT IN USE EXISTING PLUMBING FLUE VENT; TO BE USED W48 EXISTING W49 NEW W14 EXISTING W18 EXISTING W55 EXISTING W10 REPLACE W53 LEAD COATED COPPER GUTTERS AND DOWNSPOUTS LOCATION FOR ELECTRICAL UTILITIES; TO BE PAINTED TO MATCH SIDING W51 EXISTING W27 UTILITY CT CLOSET FUSED SERVICE DISCONNECT MAIN ELECTRICAL PANEL GAS METER 1A1B4B REPAIR AND REPAINT. EXISTING RAIL TO REMAIN ADD STEEL LOWER BAR TO COMPLY WITH IRC R312.1.3 EXISTING BALCONY FRAMING TO REMAIN REPAIR SNOW CLIPS EXISTING DECORATIVE ELEMENT TO REPAIR AND REMAIN (4) MECH UNITS 2' - 4 " SNOW CLIPS MATERIAL BUILD UP RE: LANDSCAPE SUBGRADE LEVEL BEYOND MATERIAL BUILD UP RE: LANDSCAPE _______ A.6.05 1 Sim 3' - 0" MATCH EXISTING HISTORIC SIDING NOTES: 1. BUILDING HEIGHT, FOOTPRINT AND MASSING MUST NOT CHANGE FOLLOWING TEMPORARY RELOCATION OF THE EXISTING ADDITION. 2. PROPOSED SNOW CLIP TO BE PLACED PER MANUFACTURER SPECIFICATIONS SUCH THAT CONFIGURATION TO BE MINIMAL NEEDED AND SHALL NOT RUN UP ALL THE WAY TO THE ROOF EDGE PER CITY OF ASPEN HISTORIC PRESERVATION. NEW W60 4" MECH VENT TERMINATION PER HPC DESIGN GUIDELINES 7.4, 12.4 24 " M I N Th e s e d o c u m e n t s a r e t h e p r o p e r t y o f EA D . A n y u n a u t h o r i z e d u s e w i t h o u t t h e wr i t t e n c o n s e n t o f E A D i s p r o h i b i t e d b y la w . E A D d i s c l a i m s r e s p o n s i b i l i t y f o r th e s e d o c u m e n t s i f t h e y a r e u s e d w h o l e or i n p a r t a t a n y o t h e r l o c a t i o n a n d f o r an y o t h e r a p p l i c a t i o n o t h e r t h a n t h e or i g i n a l i n t e n t . I f y o u a r e n o t t h e in t e n d e d r e c i p i e n t , y o u a r e h e r e b y no t i f i e d t h a t a n y d i s s e m i n a t i o n , di s t r i b u t i o n o r r e p r o d u c t i o n o f t h e s e do c u m e n t s i s p r o h i b i t e d b y l a w . 350 MARKET STREET SUITE 309 BASALT, COLORADO 81621 PHONE: 970.300.3423 FAX: 415.358.5771 INFO@EIGELBERGER.COM Co p y r i g h t c 2 0 1 8 b y E I G E L B E R G E R A R C H I T E C T U R E & D E S I GN SCALE: Plot Date Drawn By Checked By Project No. CLIENT REVIEW: REVIEWED AND APPROVED FOR DESIGN INTENT: CLIENT UNDERSTANDS THE DESIGN INTENT OF THE DOCUMENT. CLIENT APPROVES DESIGN INTENT. ARCHITECT WILL PROCEED WITH DETAILS AND COORDINATION WITH CONTRACTOR PER SIGN OFF ON DOCUMENT. NOTE: ANY CHANGES TO THE APPROVED DRAWINGS BY CLIENT ARE ADDITIONAL SERVICE PER CONTRACT. ARCHITECT TO PICKUP CORRETIONS AS NOTED CLIENT SIGNATURE: ___________________________ DATE OF APPROVAL: __________________________ Date Issue 05-28-21 90% CD 08-24-21 CD DRAFT 01-07-22 HPC REVIEW CD PROGRESS03-18-22 04-12-22 REVISIONS05-05-22 HPC REVISIONS 1/4" = 1'-0" BI M 3 6 0 : / / 1 9 0 1 7 - 1 3 4 B l e e k e r / 1 9 0 1 7 _ 1 3 4 E B l e e k e r S t _C E N T R A L . r v t 5/5/2022 9:05:20 PM A.3.01 WEST ELEVATIONS 13 4 E A S T B L E E K E R AS P E N , C O 19017 HANNAH-HUNT MOELLER Checker SCALE :1/4" = 1'-0"A.3.01 1 EXISTING WEST ELEVATION SCALE :1/4" = 1'-0"A.3.01 2 PROPOSED WEST ELEVATION 2% SLOPE AWAY 2% SLOPE AWAY 1 1 1