HomeMy WebLinkAboutFlue Approval.134 E Bleeker St.2023078
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
EE
CC
B
B
AA
SETBACK
SETBACK
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
F F
SLOPE
13 1/2" : 12"
SLOPE
10 1/2" : 12"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SLOPE
13 1/2" : 12"
SLOPE
10 1/2" : 12"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SLOPE
13 1/2" : 12"
SL
O
P
E
3
1
/
2
"
:
1
2
"
SLOPE
13 1/2" : 12"
SLOPE
13 1/2" : 12"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SLOPE
13 1/2" : 12"
SL
O
P
E
12
"
:
1
2
"
SLOPE
12" : 12"
SLOPE
12" : 12"
SLOPE
4" : 12"
SL
O
P
E
12
"
:
1
2
"
SL
O
P
E
12
"
:
1
2
"
SL
O
P
E
13
1
/
2
"
:
1
2
"
SL
O
P
E
13
1
/
2
"
:
1
2
"
1
A.4.01
2
A.4.01
1
A.4.02
2
A.4.02
PR
O
P
E
R
T
Y
L
I
N
E
SETBACK
PROPERTY LINE
SE
T
B
A
C
K
EXISTING PLUMBING
FLUE VENT; TO BE USED
HISTORIC CHIMNEY TO
REMAIN; TO BE USED
AS PLUMBING VENT
EXISTING PENETRATION;
TO BE USED FOR 6"
ROUND PLUMBING VENT
HISTORIC PENETRATION;
NOT IN USE
HISTORIC PENETRATION;
NOT IN USE
EXISTING PENETRATION;
TO BE USED FOR 8"
ROUND PLUMBING VENT
HISTORIC PENETRATION;
NOT IN USE
EXISTING CHIMNEY TO
BE USED FOR 6" VENT
R1
R1
R1
R1
R1
PROPOSED SNOW CLIP TO BE PLACED
PER MANUFACTURER SPECIFICATIONS
SUCH THAT CONFIGURATION TO BE
MINIMAL NEEDED AND SHALL NOT RUN
UP ALL THE WAY TO THE ROOF EDGE
PER CITY OF ASPEN HISTORIC
PRESERVATION
ROOF SHINGLES TO BE REPLACED PER ROOF ASSEMBLY
TYPE TO MATCH AESTHETIC CHARACTER
OF EXISTING STRUCTURE
CURRENT RIDGE FLASHING APPEARS TO BE NON-HISTORIC;
FULL REPLACEMENT IS PROPOSED ON ALL ROOFS
FLASHING AND GUTTERS
TO BE UPDATED
NOTES:
1. ALL EXISTING DIMENSIONS TO BE VERIFIED IN FIELD BY CONTRACTOR
2. REFER TO CIVIL PLANS FOR ALL DRAIN LOCATIONS
3. SNOW CLIPS PROVIDED ON ROOFS IN ORDER TO PREVENT SHEDDING OF ICE AND SNOW ONTO ADJACENT PROPERTIES,
POTENTIALLY OCCUPIED AREAS, AND VEHICULAR ACCESS PER SECTION R910
EXISTING
PENETRATION TO BE
USED FOR 8" EXHAUST
PT-01 PT-02
W53
W54
W52
3'
-
0
1
/
8
"
2'
-
0
1
/
2
"
2'
-
0
1
/
2
"
(E) SKYLIGHT TO REMAIN, REPLACE GLASS AS NEEDED
WITH .06" PVB LAMINATED GLASS PER SKYLIGHT SPEC
1A
1A
1B
1B
4B
4B
11 1/2"
6'
-
4
7
/
8
"
R1
SL
O
P
E
12
"
:
1
2
"
SL
O
P
E
12
"
:
1
2
"
SL
O
P
E
12
"
:
1
2
"
SL
O
P
E
12
"
:
1
2
"
SLOPE
12" : 12"
SLOPE
12" : 12"
SLOPE
4" : 12"
SLOPE
4" : 12"
WALKWAY WALKWAY GRAVEL WALKWAY
WALKWAY
DR
I
V
E
W
A
Y
BALCONY
BALCONY
WALKWAY
SIDEWALK
1
A.4.03
2
A.4.03
CC CC
BBBB
EEEE
D
DOWNSPOUT, TYP
DOWNSPOUT
DOWNSPOUT
8" FLUE
TERMINATION
W/ CAP
1
A.4.05A
SNOW GUARD RAILS
NEW 4" BOILER FLUE
PENETRATION
Th
e
s
e
d
o
c
u
m
e
n
t
s
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
EA
D
.
A
n
y
u
n
a
u
t
h
o
r
i
z
e
d
u
s
e
w
i
t
h
o
u
t
t
h
e
wr
i
t
t
e
n
c
o
n
s
e
n
t
o
f
E
A
D
i
s
p
r
o
h
i
b
i
t
e
d
b
y
la
w
.
E
A
D
d
i
s
c
l
a
i
m
s
r
e
s
p
o
n
s
i
b
i
l
i
t
y
f
o
r
th
e
s
e
d
o
c
u
m
e
n
t
s
i
f
t
h
e
y
a
r
e
u
s
e
d
w
h
o
l
e
or
i
n
p
a
r
t
a
t
a
n
y
o
t
h
e
r
l
o
c
a
t
i
o
n
a
n
d
f
o
r
an
y
o
t
h
e
r
a
p
p
l
i
c
a
t
i
o
n
o
t
h
e
r
t
h
a
n
t
h
e
or
i
g
i
n
a
l
i
n
t
e
n
t
.
I
f
y
o
u
a
r
e
n
o
t
t
h
e
in
t
e
n
d
e
d
r
e
c
i
p
i
e
n
t
,
y
o
u
a
r
e
h
e
r
e
b
y
no
t
i
f
i
e
d
t
h
a
t
a
n
y
d
i
s
s
e
m
i
n
a
t
i
o
n
,
di
s
t
r
i
b
u
t
i
o
n
o
r
r
e
p
r
o
d
u
c
t
i
o
n
o
f
t
h
e
s
e
do
c
u
m
e
n
t
s
i
s
p
r
o
h
i
b
i
t
e
d
b
y
l
a
w
.
350 MARKET STREET SUITE 309 BASALT, COLORADO
81621
PHONE: 970.300.3423 FAX: 415.358.5771
INFO@EIGELBERGER.COM
N
Co
p
y
r
i
g
h
t
c
2
0
1
8
b
y
E
I
G
E
L
B
E
R
G
E
R
A
R
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
GN
SCALE:
Plot Date
Drawn By
Checked By
Project No.
CLIENT REVIEW: REVIEWED AND
APPROVED FOR DESIGN INTENT:
CLIENT UNDERSTANDS THE DESIGN
INTENT OF THE DOCUMENT. CLIENT
APPROVES DESIGN INTENT. ARCHITECT
WILL PROCEED WITH DETAILS AND
COORDINATION WITH CONTRACTOR PER
SIGN OFF ON DOCUMENT.
NOTE: ANY CHANGES TO THE APPROVED
DRAWINGS BY CLIENT ARE ADDITIONAL
SERVICE PER CONTRACT.
ARCHITECT TO PICKUP CORRETIONS AS
NOTED
CLIENT SIGNATURE:
___________________________
DATE OF APPROVAL:
__________________________
Date Issue
1/4" = 1'-0"
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
1
9
0
1
7
-
1
3
4
B
l
e
e
k
e
r
/
1
9
0
1
7
_
1
3
4
E
B
l
e
e
ke
r
S
t
_
C
E
N
T
R
A
L
-
R
2
4
.
r
v
t
7/18/2023 6:33:40 PM
A.2.10
(P) ROOF PLAN
13
4
E
A
S
T
B
L
E
E
K
E
R
AS
P
E
N
,
C
O
19017
HANNAH-HUNT MOELLER
Checker
SCALE :1/4" = 1'-0"A.2.10
1 (P) ROOF PLAN
05-28-21 90% CD
08-24-21 CD DRAFT
01-07-22 HPC REVIEW
03-18-22 CD PROGRESS
04-12-22 REVISIONS
05-05-22 HPC REVISION
07-08-22 CHANGE ORDER 1
T.O.F.F. @ MAIN LEVEL
100' -0"
MAIN LEVEL CEILING @ DINING
109' -6"
(E) ROOF
125' -2 1/2"
8 7 6 5 4 3 2 1
(E/P) B.O. HEADER UL ADDITION
118' -4 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
T.O.F.F. UPPER FLOOR @ VICTORIAN
110' -8 1/2"
MAIN LEVEL CEILING @ LIVING
108' -7 3/4"
1A1B4B
T.O.F.F. @ MAIN LEVEL
100' -0"
MAIN LEVEL CEILING @ DINING
109' -6"
T.O.F.F. @ BASEMENT
87' -0"
8 7 6 5 4 3 2 1
T.O. ROOF
125' -2 1/2"
T.O.F.F. @ MAIN VICTORIAN
101' -0"
T.O.F.F. UPPER FLOOR @ VICTORIAN
110' -8 1/2"
3'
-
6
7
/
8
"
0'
-
1
1
1
/
4
"
T.O.F.F AT CRAWLSPACE
80' -6"
T.O.F.F AT CRAWLSPACE
80' -6"
ARCHITECTURAL ASPHALT SHINGLES
TO REPLACE EXISTING, TYP
(E) SIDING TO BE REPAINTED, TYP.(P) SIDING TO MATCH (E) TYP.
EXISTING SIDING TO BE REPAINTED
NEW
W57
NEW
W56
25' BUILDING HEIGHT RESTRICTION CALCULATED FROM MOST RESTRICTIVE GRADE
MAIN LEVEL CEILING @ LIVING
108' -7 3/4"
HISTORIC CHIMNEY TO REMAIN;
NOT IN USE
EXISTING PLUMBING
FLUE VENT; TO BE USED
EXISTING
W49
NEW
W14
EXISTING
W55
EXISTING
W10
REPLACE
W53
LEAD COATED COPPER
GUTTERS AND DOWNSPOUTS
LOCATION FOR ELECTRICAL
UTILITIES; TO BE PAINTED
TO MATCH SIDING
W51
EXISTING
W27
UTILITY
CT
CLOSET
FUSED
SERVICE
DISCONNECT
MAIN
ELECTRICAL
PANEL
GAS METER
1A1B4B
REPAIR AND REPAINT. EXISTING RAIL TO REMAIN
ADD STEEL LOWER BAR TO COMPLY WITH IRC R312.1.3
EXISTING BALCONY FRAMING TO REMAIN
REPAIR
SNOW CLIPS
EXISTING DECORATIVE ELEMENT TO
REPAIR AND REMAIN
(4) MECH UNITS
2'
-
4
"
SNOW CLIPS
MATERIAL BUILD UP
RE: LANDSCAPE
SUBGRADE LEVEL BEYOND
MATERIAL BUILD UP
RE: LANDSCAPE
_______
A.6.05
1
Sim
3' - 0"
MATCH EXISTING
HISTORIC SIDING
NOTES:
1. BUILDING HEIGHT, FOOTPRINT AND MASSING MUST NOT CHANGE
FOLLOWING TEMPORARY RELOCATION OF THE EXISTING ADDITION.
2. PROPOSED SNOW CLIP TO BE PLACED PER MANUFACTURER
SPECIFICATIONS SUCH THAT CONFIGURATION TO BE MINIMAL NEEDED
AND SHALL NOT RUN UP ALL THE WAY TO THE ROOF EDGE PER CITY OF
ASPEN HISTORIC PRESERVATION.
NEW
W604" MECH VENT
TERMINATION
PER HPC DESIGN
GUIDELINES 7.4, 12.4
24
"
M
I
N
02-LEVEL 25
90' -5 3/4"
02-LEVEL 25
90' -5 3/4"
MECH VENT
TERMINATION
PER HPC DESIGN
GUIDELINES 7.4, 12.4
2'
-
4
1
/
4
"
2'
-
1
"
2'
-
0
1
/
4
"
2'
-
0
1
/
4
"
2'
-
1
"
2'
-
4
1
/
4
"
2'
-
1
"
2'
-
0
1
/
4
"
1'
-
7
1
/
4
"
REPLACE
E08
GUARDRAIL AT EGRESS
WELL, SEE LANDSCAPE
L7-03 FOR DETAILS
SNOW GUARD
NEW 4" BOILER FLUE
PENETRATION
Th
e
s
e
d
o
c
u
m
e
n
t
s
a
r
e
t
h
e
p
r
o
p
e
r
t
y
o
f
EA
D
.
A
n
y
u
n
a
u
t
h
o
r
i
z
e
d
u
s
e
w
i
t
h
o
u
t
t
h
e
wr
i
t
t
e
n
c
o
n
s
e
n
t
o
f
E
A
D
i
s
p
r
o
h
i
b
i
t
e
d
b
y
la
w
.
E
A
D
d
i
s
c
l
a
i
m
s
r
e
s
p
o
n
s
i
b
i
l
i
t
y
f
o
r
th
e
s
e
d
o
c
u
m
e
n
t
s
i
f
t
h
e
y
a
r
e
u
s
e
d
w
h
o
l
e
or
i
n
p
a
r
t
a
t
a
n
y
o
t
h
e
r
l
o
c
a
t
i
o
n
a
n
d
f
o
r
an
y
o
t
h
e
r
a
p
p
l
i
c
a
t
i
o
n
o
t
h
e
r
t
h
a
n
t
h
e
or
i
g
i
n
a
l
i
n
t
e
n
t
.
I
f
y
o
u
a
r
e
n
o
t
t
h
e
in
t
e
n
d
e
d
r
e
c
i
p
i
e
n
t
,
y
o
u
a
r
e
h
e
r
e
b
y
no
t
i
f
i
e
d
t
h
a
t
a
n
y
d
i
s
s
e
m
i
n
a
t
i
o
n
,
di
s
t
r
i
b
u
t
i
o
n
o
r
r
e
p
r
o
d
u
c
t
i
o
n
o
f
t
h
e
s
e
do
c
u
m
e
n
t
s
i
s
p
r
o
h
i
b
i
t
e
d
b
y
l
a
w
.
350 MARKET STREET SUITE 309 BASALT, COLORADO
81621
PHONE: 970.300.3423 FAX: 415.358.5771
INFO@EIGELBERGER.COM
Co
p
y
r
i
g
h
t
c
2
0
1
8
b
y
E
I
G
E
L
B
E
R
G
E
R
A
R
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
GN
SCALE:
Plot Date
Drawn By
Checked By
Project No.
CLIENT REVIEW: REVIEWED AND
APPROVED FOR DESIGN INTENT:
CLIENT UNDERSTANDS THE DESIGN
INTENT OF THE DOCUMENT. CLIENT
APPROVES DESIGN INTENT. ARCHITECT
WILL PROCEED WITH DETAILS AND
COORDINATION WITH CONTRACTOR PER
SIGN OFF ON DOCUMENT.
NOTE: ANY CHANGES TO THE APPROVED
DRAWINGS BY CLIENT ARE ADDITIONAL
SERVICE PER CONTRACT.
ARCHITECT TO PICKUP CORRETIONS AS
NOTED
CLIENT SIGNATURE:
___________________________
DATE OF APPROVAL:
__________________________
Date Issue
1/4" = 1'-0"
Au
t
o
d
e
s
k
D
o
c
s
:
/
/
1
9
0
1
7
-
1
3
4
B
l
e
e
k
e
r
/
1
9
0
1
7
_
1
3
4
E
B
l
e
e
ke
r
S
t
_
C
E
N
T
R
A
L
-
R
2
4
.
r
v
t
7/18/2023 6:34:01 PM
A.3.01
WEST ELEVATIONS
13
4
E
A
S
T
B
L
E
E
K
E
R
AS
P
E
N
,
C
O
19017
HANNAH-HUNT MOELLER
Checker
SCALE :1/4" = 1'-0"A.3.01
1 EXISTING WEST ELEVATION
SCALE :1/4" = 1'-0"A.3.01
2 PROPOSED WEST ELEVATION
2% SLOPE AWAY 2% SLOPE AWAY
NOTE:
1 -FENESTRATION CHANGES APPROVED BY
HPC MONITOR 5/6/22
2 -PENETRATIONS HAVE BEEN SUBMITTED TO
HPC FOR REVIEW AND APPROVAL BY HP
MONITOR AT TIME OF CHANGE ORDER
3 -BUILDING AND SILL HEIGHTS DIFFERENCES
APPROVED BY HP MONITOR 5/15/23.
05-28-21 90% CD
08-24-21 CD DRAFT
01-07-22 HPC REVIEW
03-18-22 CD PROGRESS
04-12-22 REVISIONS
05-05-22 HPC REVISION
07-08-22 CHANGE ORDER 1
05-12-23 HPC REVIEW