HomeMy WebLinkAboutExhibit B_Commercial Design Review CriteriaExhibit B
Commercial Design Review
Land Use Code Section 26.412.020, Commercial Design Review Criteria
An application for commercial design review may be approved, approved with conditions
or denied based on conformance with the following criteria:
1. The Commercial, Lodging and Historic District Design Standards and
Guidelines are met as determined by the appropriate Commission. The
Standards and Guidelines include design review criteria that are to be used to
determine whether the application is appropriate.
Staff Response: The applicant provided a Commercial Design Review Context
Study within the application. This study responds to each of the applicable Design
Standards and Guidelines and demonstrates that the proposed project will
comply with the applicable standards.
Staff finds this criterion is met.
2. All applicable standards in the Commercial, Lodging and Historic District Design
Standards and Guidelines shall be met unless granted a Variation pursuant
to Section 26.412.040(d), Variations.
Staff Response: The project requires a small reduction in the required
Pedestrian Amenity space. Open space that currently exists along the east
(front) and north sides of the building meets the definition of Pedestrian Amenity
and cannot be reduced in size without approval. The small overhang proposed
to shelter the entry doors into the new addition decreases the Pedestrian Amenity
because the area below it will no longer be “open to the sky” as required.
Currently, 3,077 sq. ft. or 16.7 percent of this 18,458 square foot lot is Pedestrian
Amenity. The overhang is 71.7 sq. ft. reducing the Pedestrian Amenity to 3,005
square feet or 16.3 percent of the lot.
The review criteria are:
D. Variations. An application requesting a variation from the Standards of
Commercial, Lodging, and Historic District Design Standards and Guidelines shall
be reviewed during either Conceptual Design Review or Final Design Review, as
determined by the Community Development Department. The Planning & Zoning
Commission or Historic Preservation Commission, during a duly noticed public
hearing, shall approve, approve with conditions, or deny an application for
variation. The application shall demonstrate, and the deciding board shall find that
the variation, if granted, would:
1. Provide an alternative design approach that meets the overall intent of
the standard. The reviewing board shall consider the appropriateness of
the design features, building elements, and existing neighborhood context
to determine that the exception is appropriate; or
Exhibit B
Commercial Design Review
2. Be clearly necessary for reasons of fairness related to unusual site-
specific constraints.
The slight overhang provides protection from weather at the entry and, as a
cantilevered element, has a minimal impact on the sense of open space at the
front of the property, and meets the intent of the guideline below.
PA1.5 Street level Pedestrian Amenity areas shall be open to the sky.
• Direct access to the Pedestrian Amenity from the street is required.
• A street level Pedestrian Amenity space may be covered, subject to HPC
or P&Z approval. If the space is covered, the street-facing portion shall be
entirely open.
Staff finds this criterion is met.
3. Not every guideline will apply to each project, and some balancing of the
guidelines must occur on a case-by-case basis. The applicable Commission
must:
a. Determine that a sufficient number of the relevant guidelines are
adequately met in order to approve a project proposal;
b. Weigh the applicable guidelines with the practicality of the measure.
Staff Response: Staff finds that a sufficient number of relevant guidelines are
met.
Exhibit B
Commercial Design Review
General
Site Planning & Streetscape
1.1 All projects shall provide a context study.
A context study was provided as part of this application. Staff finds this
criterion met.
1.2 All projects shall respond to the traditional street grid.
The existing building is situated parallel to N. Mill Street. The proposed
project will not alter the building orientation. Staff finds this criterion met.
1.3 Landscape elements (both hardscape and softscape) should complement
the surrounding context, support the street scene, and enhance the
architecture of the building.
All but one existing tree will remain in place. Additional shrubs will be
planted to soften the base of the addition. Much of the street facing sod
will be replaced with river rock xeriscaping. Any tree removal requires
approval from the Parks Department. Staff finds this criterion met.
1.4 Where there is open space on a site, reinforce the traditional transition
from public space, to semi-public space to private space.
Permeable pavers will be installed from the sidewalk along N. Mill Street
to the new entry door. Staff finds this criterion met.
1.5 Maintain alignment of building facades where appropriate.
The existing building is closely aligned to Clark’s Market to the north and
the adjacent duplex to the south. The building orientation will not change
as part of this project. Staff finds this criterion met.
1.6 When a building facade is set back, define the property line. Review the
context of the block when selecting an appropriate technique.
The existing planter links the public streetscape and entry to the property.
New benches on top of the planter are proposed as a pedestrian amenity.
Staff finds this criterion met.
Alleyways
1.7 Develop alley facades to create visual interest.
N/A
1.8 Consider small alley commercial spaces, especially on corner lots or lots
with midblock access from the street.
N/A
Exhibit B
Commercial Design Review
Parking
1.9 Minimize the visual impacts of parking.
N/A
Building Mass, Height, and Scale
1.10 A new building should appear similar in scale and proportion with
buildings on the block.
The existing building and proposed entry addition are similar in scale and
proportional to adjacent buildings. Staff finds this criterion met.
1.11 A minimum building height difference of 2-ft. from immediately adjacent
buildings is required.
The entry addition will be 2-ft, 2-inches higher than the existing building
and noticeably different from the two adjacent buildings. Staff finds this
criterion met.
1.12 On lots larger than 6,000 sq. ft., break up building mass into smaller
modules.
The proposed entry can be considered a unique, smaller module, relative
to the remainder of the building. The new addition will help to break up
building mass. Staff finds this criterion met.
1.13 Development adjacent to a historic landmark should respond to the
historic resource.
N/A
Street Level Design
1.14 Commercial entrances shall be at the sidewalk level and oriented to the
street.
The proposed entry addition is accessed from the sidewalk and is
oriented towards North Mill Street. One of the principal design goals of
this project is to establish a single, street-oriented entrance to all
businesses within the building. Currently, most of the businesses are
accessed via the rear of the building. Staff finds this criterion met.
1.15 Incorporate an internal airlock or air curtain into first floor commercial
space.
The entry addition is designed as a 3-level airlock with automatic closing
doors at each level. Staff finds this criterion met.
Exhibit B
Commercial Design Review
1.16 Entries that are significantly taller or shorter than those seen historically
or that conflict with the established scale are highly discouraged.
The proposed entry is slightly taller than the existing building but is still
considered proportional in scale and mass to the existing building. The
size and height of the entry is also proportional to buildings within the
surrounding neighborhood. Staff finds this criterion met.
1.17 ATMs and vending machines visible from the street are prohibited.
N/A
Roofscape
1.18 The roofscape should be designed with the same attention as the
elevations of the building.
N/A
1.19 Use materials that complement the design of the building façade.
The modern design of the glass and steel entry addition contains the
internal function of the elevator shaft and stairway that wraps it. The
chosen use of the steel in the entry relates to other steel elements in the
neighborhood such as the Ron Krajian Bridge. Staff finds this criterion
met.
1.20 Incorporate green roofs and low landscape elements into rooftop design
where feasible.
The new roof membrane will match with the existing. The new roof will
have high reflectance properties to reduce localized heat island effects.
Staff finds this criterion met.
1.21 Minimize visibility of rooftop railings.
N/A
Materials & Details
1.22 Complete and accurate identification of materials is required.
The applicant has provided a complete list of materials. Staff finds this
criterion met.
1.23 Building materials shall have these features:
− Convey the quality and range of materials found in the current block
context or seen historically in the Character Area.
− Convey pedestrian scale.
− Enhance visual interest through texture, application, and/or dimension.
− Be non-reflective. Shiny or glossy materials are not appropriate as a
primary material.
Exhibit B
Commercial Design Review
− A material with an integral color shall be a neutral color. Some variation
is allowed for secondary materials.
The two primary materials of the entry connection include black
structural steel and glass. These materials will be used extensively to
complement the adjacent building to the south, 201 North Mill as well as
the brick façade of the existing building, which remains the dominant
element. Visual interest is enhanced by the use of glass walls by allowing
pedestrians to see the elevator shaft and winding wood stair treads
within. The glass will be non-reflective and the steel will be matte. Staff
finds these criteria met.
1.24 Introducing new material, material application, or material finish to the
existing streetscape may be approved by P&Z if the following criteria
are met [Not listed here].
N/A
1.25 Architecture that reflects corporate branding of the tenant is not
permitted.
N/A
Lighting, Service and Mechanical Areas
1.26. The design of light fixtures should be appropriate to the form, materials,
scale and style of the building.
Lighting selection was conducted with respect to maintaining night sky
requirements and a minimalist design aesthetic to reflect upon the
modern entry addition. Staff finds this criterion met.
1.27 Trash and recycle service areas shall be co-located along an alleyway
where one exists and screened from view with a fence or door.
N/A
1.28 Design trash and recycle areas thoughtfully and within the style of the
building, with the goal of enhancing pedestrian and commercial uses
along alleys.
N/A
1.29 Delivery areas shall be located along an alleyway where one exists.
N/A
1.30 Mechanical equipment, ducts, and vents shall be accommodated
internally within the building and/or co-located on the roof.
All mechanical equipment will be located out of site from Mill Street.
Staff finds this criterion met.
Exhibit B
Commercial Design Review
1.31 Minimize the visual impacts of utility connections and services boxes.
Existing street-side service and utility boxes will be minimized and
screened with new evergreen shrubs. Staff finds this criterion met.
1.32 Transformer location and size are dictated by City and utility company
standards and codes.
N/A
Remodel
1.33 All remodel projects shall meet Standards 1.22 and 1.23
See standards 1.22 & 1.23
1.34 Consider updating windows, doors, and/ or primary entrances to better
relate to the Character Area and pedestrian experience.
The proposed entry connection with its industrial steel frame, uses new,
high performance windows and an entry door that relate closely to the
adjacent 201 North Mill building and the character of the River Approach
zone. Staff finds this criterion met.
1.35 Design alterations to relate to the existing building style and form that
may remain.
The black steel frame and the natural color palette of the interior
materials will blend well with the brick facades of the existing building
which remain the dominant element. Staff finds this criterion met.
1.36 Incorporate elements that define the property line in accordance with
Guideline 1.6.
An existing planter bridges the public streetscape and entry to the
property. A new bench on top of the planter is proposed as a pedestrian
amenity. Staff finds this criterion met.
1.37 Creative solutions that incorporate ADA compliance into the architecture
are encouraged.
Part of this remodel includes making all three floors and all bathroom
facilities ADA compliant with the introduction of the street accessible
elevator.
Pedestrian Amenities
This project does not trigger demolition. The proposed reduction is addressed
above. Additionally, the applicant proposes adding south and north facing
benches mounted onto the existing triangular concrete planter. Staff finds all
applicable criteria related to pedestrian amenities met.
Exhibit B
Commercial Design Review
River Approach Character Area
7.1 Place a building to respond to the natural environment.
N/A
7.2 Minimize retaining walls where possible by siting building into topography.
N/A
7.3 Incorporate open space into the building placement and site design.
N/A
Architecture
7.4 Preserve the diverse and industrial character of the neighborhood and
encourage connection to the river and natural environment.
The proposed entry connection uses exposed, black structural steel to
define the mass of the element within the larger existing brick building.
This helps tie 225 North Mill to the historical and neighborhood vernacular
of the River Approach Zone. Staff finds this criterion met.
7.5 Use eclectic and creative approaches to the break up building mass and
scale.
By nature of the project’s scale, the massing of the new entry addition
breaks up the monotony of the existing homogenous brick walls. Staff
finds this criterion met.
7.6 Unique roof forms and overall building shape are encourages in this
neighborhood.
The roof form seeks to relate to the adjacent building to the south, 201
North Mill with a flat roof. Staff finds this criterion met.
7.7 Enhance the natural environment and funky character through materials
and details.
The new elevator shaft and wood stair treads resembling railroad ties will
be visible through the new front fenestration. Staff finds this criterion
met.
7.8 Larger, more industrial sized fenestration is appropriate here.
Large, industrial sized fenestration is prominent in the entry addition of
225 North Mill.