HomeMy WebLinkAboutMemo_225 Smuggler_RDS Variation MEMORANDUM TO: Planning & Zoning Commission FROM: Garrett Larimer, Senior Planner THRU: Amy Simon, Planning Director RE: 225 Smuggler Rd. – RDS Variation for Articulation of Building Mass & Window Placement MEETING DATE: May 18th, 2021 APPLICANT: Continental Holdings LLC 15 E. 26th St., Suite 602 New York, New York 10010 REPRESENTATIVE: Carson Davis, EYRC Architects 10865 Washington Blvd., Culver City, CA 90232 LOCATION: 225 W. Smuggler St. ZONING: Moderate Density Residential, (R-6) SUMMARY: The Applicant is requesting variations to the Articulation of Building Mass and Window Placement Residential Design Standards (RDS) in order to redevelop the lot with a single-family residence. STAFF RECOMMENDATION: Staff recommends that the Planning and Zoning Commission approve the requested variations. Figure 1: Subject Site Figure 2: Proposed Rendering (North Facade) Page 2 of 9 225 Smuggler St. Resolution No. __, Series of 2021 REQUEST OF THE PLANNING AND ZONING COMMISSION: The Applicant requests the Planning and Zoning Commission consider two Residential Design Standards Variations (Section 26.410.020.C Variations): 1. Articulation of Building Mass (Section 26.410.030.B.1) for a design alternative that does not meet any of the three options provided in the code. 2. Window Placement (Section 26.410.030.E.2) for a window that measures more than 10’ and spans two stories. Applications that do not comply with the standards contained in the RDS section of the code must apply for alternative compliance review for an RDS Variation. Each standard is identified in the code as either “flexible” or “non-flexible.” The code allows for alternative compliance for flexible standards to be reviewed administratively, but non-flexible standards must be reviewed by the Planning and Zoning Commission (P&Z). In order to qualify for a variation, a finding must be made that: 1. A design alternative is provided that meets the intent of the standard, as well as the general intent statements in the RDS Chapter; OR, 2. Be clearly necessary for reasons of fairness related to unusual site-specific constraints, in essence a hardship. The Articulation of Building Mass standard is a non-flexible standard. The Window Placement Standard is a flexible standard. The two flexible and non-flexible standards have been combined into a single review at P&Z for efficiency. The P&Z can approve, approve with conditions, or deny an application after considering a recommendation by the Community Development Director based on the standards outlined in section 26.410.020.C, Variation Review Standards. The Planning and Zoning Commission is the final review authority. LOCATION/BACKGROUND: The subject site is located across the street from Triangle Park in the west end. The lot is 6,000 square feet and is zoned R-6. The property currently contains a single-family residence that was built in 1995 which is proposed to be demolished and replaced. Staff has reviewed the application for compliance with the Residential Design Standards and determined that all other standards have been met or do not apply. The RDS Checklist is attached as Exhibit B, for reference. Figure 3: Existing Residence Page 3 of 9 225 Smuggler St. Resolution No. __, Series of 2021 REQUEST: Residential Design Standard Variations Articulation of Building Mass: The Articulation of Building Mass Standard provides three options for compliance: 1. Maximum Sidewall depth, 2. Off-set with One-Story Ground Level Connector, 3. Increased Side Setbacks at reard and Step Down. Option 1, Maximum Sidewall Depth, sets a maximum sidewall depth (front most wall to rear most wall) as 50’. There are no requirements for articulation, or restrictions on massing, within the 50’ maximum sidewall depth option. Option 2, Off-set with One-Story Ground Level Connector, requires a one-story connector between two-story massing elements. The one- story connector must be within 45’ of the front most wall, must be at least 10’ long, and must be setback 5’ from the sidewall of the primary structure. Option 3, Rear stepdown, requires a one-story element at the rear of the structure, that must start within 45’ feet from the front most wall, and must be setback from the sidewall of the primary structure 5’. In order to comply with the standard, one of the three options must be met. The current design does not meet any of the three options. The intent of the Articulation of Building Mass Standard is “…to reduce the overall perceived mass and bulk of buildings on a property as viewed from all sides. Designs should promote light and air access between adjacent properties. Designs should articulate building walls by utilizing multiple forms to break up large expansive wall planes. Buildings should include massing and articulation that convey forms that are similar in massing to historic Aspen residential buildings. This standard is critical in Figure 4: Option 1 - Maximum Sidewall Depth Figure 5: Option 2 - Off-set with One-Story Ground Level Connector Figure 6: Option 3 - Increased Side Setbacks at Rear and Step Down Page 4 of 9 225 Smuggler St. Resolution No. __, Series of 2021 the Infill Area where small lots, small side and front setbacks, alleys and historic Aspen building forms are prevalent. Designs should change the plane of a building's sidewall, step a primary building's height down to one-story in the rear portion or limit the overall depth of the structure.” Window Placement: The Window Placement Standard applies to all lots except those on lots located substantially above the elevation of the adjacent right-of-way. The standard requires all street facing windows span less than one-story as defined by RDS. One story is defined in the RDS Chapter as 10’. The intent of the standard is, “to preserve the historic architectural character of Aspen by preventing large expanses of vertical glass windows that dominate street-facing façades. Overly tall expanses of glass on a street-facing façade do not relate well to human scale. Designs should utilize windows that provide a sense of demarcation between stories and pedestrian scale. Where an upper story window is located directly above a lower story window, a gap with no window should be provided between them that is easily recognizable from the street and clearly differentiates lower and upper stories. This standard is important in all areas of the city.” PROPOSAL: The Application includes a design with an overall sidewall depth (front most wall to rear most wall) of ~79’. A one-story garage is off the rear of the structure accessed from the alley and measures ~25’. The west façade, or top of Figure X, steps back 5’ at a sidewall depth of ~44’ from the front most wall. The east façade steps back ~14’ at 54’. Figure 7 West Facade Page 5 of 9 225 Smuggler St. Resolution No. __, Series of 2021 The second story contains an architectural projection that cantilevers over the 1st story and is the front most street facing feature of the structure. This feature does not count toward the measurement of the sidewall but does affect perceived massing of the building from both side yards. The architectural projection measures just over 6’. Figure 7: Proposed Rendering (Northeast corner of property) Figure 8: West Facade (highlighting architectural projection) Page 6 of 9 225 Smuggler St. Resolution No. __, Series of 2021 The front façade contains a glass stair enclosure to the west of the primary two-story mass. The western most portion of the two storytwo-story glass stair enclosure measures approximately 21’6”, exceeding that maximum window height of 10’ allowed by the code. Figure 9: Proposed Rendering ( Northwest corner of property - highlighting stair enclosure) Figure 10: Close-up of stair enclosure Page 7 of 9 225 Smuggler St. Resolution No. __, Series of 2021 Figure 11: North Elevation STAFF DISCUSSION: Articulation of Building Mass The intent of this standard is to provide articulation of form to prevent large, expansive wall planes, and to reduce the perceived mass of a building. This can be achieved by a change in the plane of the sidewalls. This standard is identified as critical in the Aspen Infill area. Staff has found the proposed design to meet the intent of the Articulation of Building Mass Standard intent statement, as well as the General Intent Statements. On the west façade the proposed design meets Option 2 – Off-Set One-Story Ground Level Connector because a 5’ setback from the primary sidewall is provided within 45’ of the front most wall. To comply with Figure 12: Proposed Rendering (Southwest perspective, from alley) Page 8 of 9 225 Smuggler St. Resolution No. __, Series of 2021 that standard, a 5’ setback must be provided within 45’ on each side of the structure. On the east side the step-down doesn’t occur until 54’. On the east façade, the proposed design uses changes in wall plane, fenestration, and materials to articulate the façade. The design provides includes visual interest and a variety of textures that it helps to break up the wall plane and prevents the wall from appearing as overly large or expansive. On this façade a ~14’ setback is proposed from the side wall at 54’. Although this is 9’ beyond the step-down requirement for Option 2, it is almost three times the minimum required setback. This further contributes to the proposed design resulting in an appropriate or reduced perceived mass on this side. Although the dimensions of the design don’t fit squarely in any of the three options provided, there are elements of options 2 and 3 that are provided. A one-story element makes up approximately a third of the overall length, is at the rear of the structure and is consistent with historical architectural development patterns in Aspen. The garage is one story, to the rear, with a two-story primary massing element to the front of the lot. The two-story component, although one side wall does not meet the step-down dimensional requirement, it does use design elements that achieve the intent of the standard. Window Placement: The proposed window measures ~21’6” and spans 2 stories, in practice, and as it relates to the definition in the RDS. The proposed window includes a mullion at the midpoint of the window, and metal screening over the entire glass stair enclosure. Typically, mullions are not considered to provide an adequate gap breaking up a window when considering the Window Placement Standard. Staff has found the use of the metal screening, the mullions, and width of the window relative to the remaining front façade, as design alternatives provided that help meet the intent Figure 13: Proposed Rendering (Southeast perspective - from alley) Figure 14: Front Facade Page 9 of 9 225 Smuggler St. Resolution No. __, Series of 2021 of the standard. The Applicant has indicated the screening will remain fixed, except during maintenance and cleaning. The window is also immediately behind a entry feature that is one- story which helps demarcate the first and second level. With all of these factors considered collectively, Staff has found the proposed design to meet the intent of the standard. STAFF RECOMMENDATION: Staff recommends approval of variations to the Articulation of Building Mass and Window Placement Standards as a design alternative is provided meeting the standard’s intent, as well as the General Intent Statements. PROPOSED MOTIONS: “I move to approve Resolution No. __, Series of 2021, approving variations to the Articulation of Building Mass and Window Placement Residential Design Standards, in order to redevelop the property with a single-family residence, as depicted in Exhibit A to the resolution.” Attachments: Exhibit A – Application (Compiled) Exhibit B – RDS Checklist Exhibit C – Residential Design Standard Variation Review Criteria Exhibit D – Public Notice Affidavits