Loading...
HomeMy WebLinkAboutMemo.121WBleeker.20210324_edits Page 1 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com Memorandum TO: Aspen Historic Preservation Commission FROM: Sarah Yoon, Historic Preservation Planner THROUGH: Amy Simon, Planning Director MEETING DATE: March 24, 2021 RE: 121 West Bleeker Street – Conceptual Major Development, Relocation, Dimensional Variations and a Floor Area Bonus, PUBLIC HEARING APPLICANT /OWNER: 121 W Bleeker LLC REPRESENTATIVE: 1 Friday Design LOCATION: Street Address: 121 W. Bleeker Street Legal Description: The East ½ of Lot C, All of Lot D, and the West ½ of Lot E, Block 58, City and Townsite of Aspen, Colorado Parcel Identification Number: PID# 2735-124-39-003 CURRENT ZONING & USE R-6 (Moderate-Density Residential); Single-family home PROPOSED ZONING & USE: No change SUMMARY: The applicant requests approval for Conceptual Major Development to demolish all non-historic alterations and additions, to relocate the historic home on a new basement and to construct a new addition to the rear of the property. Dimensional variations and a 250 s.f. floor area bonus areis requested for this proposal. As a historically designated landmark, theis project is exempt from Residential Design Standards Review (RDS). STAFF RECOMMENDATION: Staff recommends continuation to restudy the design of the new addition with comments provided on page 6 of this memo. Site Locator Map – 121 W. Bleeker Street 121 Page 2 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com BACKGROUND: 121 W. Bleeker is a 6,000 s.f. lot in the R-6 residential zone district. This property contains a Victorian era home that was historically designated via Ordinance 34, Series of 1992. Building permit records show various alterations were made to the historic resource that include the addition of large dormers and a new porch to the west elevation. Setback variances for these extensions were granted by the Board of Adjustment in the early 1990s. Although the Sanborn Map indicates the home is in its original location, numerous alterations have resulted in the loss of historic building fabric. REQUEST OF HISTORIC PRESERVATION COMMISSION (HPC) The Applicant is requesting the following land use approvals: • Major Development (Section 26.415.070.D) to demolish non-historic alterations and additions made to the historic home and construct a new addition to the rear of the property. • Relocation (Section 26.415.090) to place relocate the historic resource onto a new basement but maintain the same location on the site. • Setback Variation (Section 26.415.110.C) to grant setback reductions for the portionselements of the new addition and for mechanical equipment. • Height Exception (Section 26.575.020.F.4.j) for the measurement of the height of the new addition where it abuts a large lightwell on the east side of the property. the 197 s.f. lightwell. • Floor Area Bonus (Section 26.415.110.F) allowed to request up to 250 sf of additional floor areabut must meet all relevant criteria for the bonus including exceptional preservation outcome. The Historic Preservation Commission (HPC) is the final review authority, however, Conceptual approval this project is subject to Call-up Notice by City Council. PROJECT SUMMARY: The applicant proposes to remove all detrimental alterations on the historic resource and to restore it back to its historic appearance. Excavation for a new basement is proposed and the historic home will be relocated on a new foundation but maintain its historic location on the lot. The new addition is concentrated to the rear of the property and a large lightwell is proposed to the east side of the lot to provide more daylighting for the subgrade living area. Dimensional variations for the new addition and a 250 s.f. floor area bonus are requested for this design. STAFF COMMENTS: Compared to the size of the lot, the two-story historic resource has a rather small building footprint. The historic roof form and architectural character of the home as seen from Bleeker Street is evident, however, past alterations and expansions resulted in the permanent loss of historic Figure 1 – 121 W. Bleeker, 2000 Page 3 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com building material, especially to the south elevation. Staff supports the removal of all non-historic additions detrimental alterations and the restoration of the historic resource. Staff finds the proposed wider than typical connecting element which is wider than typically allowed, is appropriate for this project because much of the south wall of the historic house has been demolished in the past. Staff elevation is not historic and supports the location of the new addition as it relates to the lot but recommends the applicant restudy the massing and footprint of the new addition. While dimensional variations for the new addition may be supported, staff recommends reducing the new massing that extends towards the east side yard. The floor area bonus of 250 s.f. may be appropriate if more of the new addition could be concentrated directly behind the historic resource. Staff recommends HPC discuss and provide more direction regarding the following topics. 1. Site Planning and Relocation: The placement of the two-story historic resource appears to be in its original historic location according to the Sanborn Map. There are two large cottonwood tree street trees along West Bleeker Street and alley access for parking. A simple stone walkway is proposed with a bend due to the drip line of the cottonwood tree. Staff recommends the walkway be no more than 3’ in width, utilizing a historic native stone such as red sandstone, flagstone pavers set in sand (Design Guideline 1.6). The open green space that dominates the front of the site complements the historic resource and supports the idea of a traditional front yard as designed. A large patio is proposed directly behind the historic resource on to the west side of the lot. A fire feature and an egress window well are incorporated into this patio feature. The location of the fire feature is not permitted according to the land use code (built in features are not permitted between a façade and a street) and will need to be relocated, and staff recommends the patio be pull away from the corner of the historic resource so that the resource meets natural landscape grade rather than the paving. Staff supports the general location of the addition on the lot but finds the proposed building footprint of the addition to be out of scale as it spans expands the entire width of the lot, dominating the historic resource from the street view.. Page 4 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com The historic resource will sit on a new basement foundation, and a light well is proposed on the east façade. The foundation detail will need to appear similar in design and materials to the historic foundation and the curb height of the lightwell needs to be 6” or less in height to minimize visual impact (Design Guideline 9.5 and 9.6). 2. Historic Landmark – Restoration: BThe building permit files indicate the existing dormers on the Victorian were added in the 1960s, and a series of other additions and alterations extensions followed. The entry porch was enclosed sometime between the 1970-1980, and in 1991 a permit was issued to add another porch feature to the west elevation. The applicant proposes to remove the alterations that directly impact the historic resource and to restore the resource using historic photographs. Staff supports the restoration of the resource using historic documentation, and the building permit files and physical inspection. It is important to note that the applicant will need to work closely with the Zoning and Building Department to ensure that the existing height conditions are maintained. 3. New Addition – Form, Materials and Fenestration: The new addition has a 12’ long one- story connecting element directly behind the historic landmark. This connecting element is wider than the typical passageway that is preferred, but staff finds this is appropriate for this project because the south elevation of the historic resource was demolished in the 1970s and 1980s when the home was significantly altered. Gabled roof forms and cedar siding are proposed for the new addition, which relates to the historic resource. The proposed fenestration deviates fromorm the historic resource (Design Guideline 10.6). Although the new addition is pushed to the rear of the lot and the area for a new addition is limited due to the landmark remaining in its historic location, staff recommends the applicant restudy the building footprint and massing of the new addition to be more directly on axisin line with the resource. Specifically, staff recommends the applicant restudy the building footprint that extends to the west of the property that places the exterior staircase in the side yard setback. Staff finds that the placement of the addition does not minimize visual impact (Design Guideline 10.10). Figure 2 – Proposed Site Plan Commented [AS1]: This isn’t an issue now that we’ve determined the Victorian is well under the height limit… Commented [AS2]: I wouldn’t say that it is just that west end of the addition that is a problem from a width perspective. The whole second floor of the addition is wide and could use reduction. Page 5 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com 4. Dimensional Variations & Floor Area Bonus: Setback variations and floor area bonuses are benefits available to historic properties if granted by the HPC. For lightwells over 100 s.f., HPC may grant an exception to the methodology for calculating height. All historic preservation benefits are granted as site-specific approvals that are tied to a specific design reviewed for compatibility and appropriateness. Setback Variations: The applicant requests a reduction from the 10’ rear yard setback requirement for the proposed addition, above and below grade. The proposed design shows the subgrade level within the rear yard setback by approximately 5’. The proposed above grade two-car garage addition has livable space on top that is also 5’ within the rear yard setback. The mechanical equipment proposed in the east side yard setback is taller than 30” and needs a 3’-10” side yard setback reduction. Staff finds the request for the rear yard setback and east side yard setback variations meet the criteria. The applicant seeks a west side yard setback variation for the exterior stairs that provide access to the rooftop deck above the garage. Staff recommends restudy of the massing and building footprint for this area of the addition because it does not meet the historic preservation design guidelines. See Exhibit A.3 for detailed staff findings. Floor Area Bonus: The applicant plans to demolish all non-historic additions and restore important architectural features such as the front porch and chimney. The proposed design reinforces the front entry as the main entrance to the home. While the restoration efforts will vastly improve the visual appearance of the historic home, staff recommends restudy of the new addition to be more compliant with Design Guidelines 10.8 and 10.10. See Exhibit A.4 for criteria and detailed staff findings. Figure 3 – Proposed North (Front) Elevation Commented [AS3]: They also need a reduction of the combined setback, which is 15’. Page 6 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com Height Exception for Lightwells: Any lightwell over 100 square feet in size triggers the requirement that building height be measured from the bottom of the lightwell, rather than from the ground level of the site. An exception to this is available as a benefit to landmark properties. The proposed lightwell on the on the east elevation of this projectthat abuts the new addition, is over 100 s.q. and provides generous daylighting for the subgrade living space. This lightwell is located approximately 49’ from the front property line and is not easily visible from Bleeker Street. The east side yard is adjacent to an unusual condition, an access driveway that serves the Hotel Aspen and connects with the alley serving this block. A alley but there is a row of mature vegetation that screens the 121 W. Bleeker property, and the proposed lightwell from clear view from this driveway. The large lightwell improves livability for the basement level allows for more livable subgrade and helps reduce the above grade massing. This concepts is reflected in the floor plans, that show all bedrooms except the master suite in the basement. Staff finds the exception criteria are met to grant an exception to height for the proposed lightwell. The applicant will have to work with Zoning to confirm that, even with the granting of an exception to the methodology of calculating height, the above grade construction adjacent to the lightwell is within the 25’ height limitation. Setback Variations: The applicant requests a reduction from the 10’ rear yard setback requirement for the proposed addition, above and below grade. The proposed design shows the subgrade level within the rear yard setback by approximately 5’. The proposed above grade two-car garage addition has livable space on top that is also 5’ within the rear yard setback. The mechanical equipment proposed in the east side yard setback is taller than 30” and needs a 3’-10” side yard setback reduction. Staff finds the request for the rear yard setback and east side yard setback variations meet the criteria. The applicant seeks a west side yard setback variation for the exterior stairs that provide access to the rooftop deck above the garage. Staff recommends restudy of the massing and building footprint for this area of the addition because it does not meet the historic preservation design guidelines. See Exhibit A.3 for detailed staff findings. Floor Area Bonus: The applicant plans to demolish all non-historic additions and restore important architectural features such as the front porch and chimney. The proposed design reinforces the front entry as the main entrance to the home. While the restoration efforts will vastly improve the visual appearance of the historic home, staff recommends restudy of the new addition to be more compliant with Design Guidelines 10.8 and 10.10. See Exhibit A.4 for criteria and detailed staff findings. REFERRAL COMMENTS: Commented [AS4]: I’m not sure this is really true. The above grade massing is significant and mostly two story. Most projects we see have all the bedrooms in the basement. I’m not opposed to this exception, but it would seem to be more on the basis of the minimal visibility of the oversized lightwell. Page 7 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com The application was referred out to other City departments who have requirements that will significantly affect the permit review. Please see Exhibit B for full comments. A summary of the comments that must be resolved before HPC or carried forward as conditions of approval are: Engineering Department: 1. Proposed excavation for a water service line within the drip line of a large tree that will need to be reviewed by the Parks Department. 2. Location of drywells need to be minimum of 10’ a way fromor the property lines. A variance request can needs to be submitted for review. 3. Clarification regarding the transformer is required. Information about available capacity needs to be reviewed by the City Electric Department. Building Department: 1. Fire sprinklers will be required because the fire area exceeds 5,000 s.f. 2. Proposed exterior stairs to the roof deck does not meet fire separation distance requirements. 3. Window wells without guard protection areis not allowed in a patio. 4. An Eemergency escape and rescue opening is needed for the guest master suite located in the historic resource. 5. The Llocation of hot tub proposed on the roof deck needs to be 18” from the edge of the deck, or a guard needs to extend 18” above the top of the hot tub. 6. Snow retention is needed on the east side of the historic roof where the window well is located. Zoning Department: 1. The Pproposed fire feature and built-in barbeque areis not allowed between a street and structure. 2. Setback variations are needed for the proposed exterior stairs, second floor deck on the rear addition, and the AC units. 3. The proposed lightwell larger than 100 s.f. requires an exception from the methodology of calculating height height variation from HPC. The height measurement needs to be clarified. RECOMMENDATION: A proposed resolution is attached, however Sstaff recommends the Historic Preservation Commission (HPC) continue this application with the following direction: 1.) Restudy the building footprint and massing of the new addition, specifically the area that extends to the west side of the lot, to meet Design Guidelines 10.8 and 10.10 and reduce setback variations.. 2.) Reduce the proposed patio on the west side of the lot to allow vegetation to surround the historic landmark, to meet finished grade and remove or relocate remove the proposed fire feature and BBQ to zoning compliant locations.. 3.) Work with relevant City Departments regarding comments related to the transformer, new water line and the stormwater mitigation plan. Page 8 of 8 130 South Galena Street Aspen, CO 81611-1975 | P: 970.920.5197 | cityofaspen.com ATTACHMENTS: Resolution #____, Series of 2021 Exhibit A.1 – Historic Preservation Design Guidelines Criteria / Staff Findings Exhibit A.2 – Relocation Review Criteria / Staff Findings Exhibit A.3 – Dimensional Variations Review Criteria / Staff Findings Exhibit A.4 – Floor Area Bonus / Staff Findings Exhibit B – Referral Comments Exhibit C – Application