HomeMy WebLinkAboutExhibitA.4 FloorAreaBonus
Page 1 of 3
Exhibit A.4
Floor Area Bonus Criteria
Staff Findings
26.415.110.F Floor Area Bonus:
1. In selected circumstances, the HPC may grant up to five hundred (500) additional square feet of
allowable floor area for projects involving designated historic properties. The potential bonus is
determined by net lot area such that a 3,000-5,999 square foot lot is eligible for a maximum of a two
hundred fifty (250) square foot floor area bonus, a 6,000-8,999 square foot lot is eligible for a
maximum of a three hundred seventy five (375) square foot floor area bonus and a 9,000 square
foot or larger lot is eligible for a maximum of a 500 square foot floor area bonus. Floor area bonuses
are cumulative. More than one bonus may be approved up to the maximum amount allowed for the
lot. If a property is subdivided, the maximum bonus will be based on the original lot size, though the
bonus may be allocated amongst the newly created parcels to the extent permitted.
On any lot where a historic property is permitted a duplex density while a non-historic property is
not, the increased allowable floor area that results from the density will be deducted from the
maximum bonus that the property may receive.
To be considered for the bonus, it must be demonstrated that the project meets all of the following
criteria:
a) The historic building is the key element of the property, and the primary entry into the
structure, and the addition is incorporated in a manner that maintains the visual integrity of
the historic building; and
b) If applicable, historically significant site and landscape features from the period of
significance of the historic building are preserved; and the applicant is undertaking multiple
significant restoration actions, including but not limited to, re-opening an enclosed porch,
re-installing doors and windows in original openings that have been enclosed, removing
paint or other nonoriginal finishes, or removing elements which are covering original
materials or features; and
c) The project retains a historic outbuilding, if one is present, as a free standing structure above
grade; and
d) The applicant is electing a preservation outcome that is a high priority for HPC, including
but not limited to, creating at least two detached structures on the site, limiting the amount
of above grade square footage added directly to a historic resource to no more than twice
the above grade square footage of the historic resource, limiting the height of an addition to
a historic resource to the height of the resource or lower, or demolishing and replacing a
significantly incompatible non-historic addition to a historic resource with an addition that
meets current guidelines.
2. Granting of additional allowable floor area is not a matter of right but is contingent upon the sole
discretion of the HPC and the Commission's assessments of the merits of the proposed project and
its ability to demonstrate exemplary historic preservation practices.
Page 2 of 3
3. The decision to grant a floor area bonus for major development projects will occur as part of the
approval of a Conceptual Development Plan, pursuant to Subsection 26.415.070.D.
4. Floor area bonuses are only available for single-family, duplex or 100% affordable housing
development. A property shall receive no more than 500 square feet total. The award of a bonus is
project specific. At such time that more than 40% of an addition to a historic resource that was
constructed as part of a project which previously received a floor area bonus is demolished, the
bonus may be retained only if the proposed redevelopment is found to meet the requirements of this
Section.
5. Separate from the floor area bonus described above, on a lot that contains a historic resource, HPC
may exempt wall exposed by a light well that is larger than the minimum required for egress from
the calculation of subgrade floor area only if the light well is internalized such that it is entirely
recessed behind the vertical plane established by the portion of the building façade(s) closest to any
street(s), the light well is screened from view from the street by building walls or fences, and any
addition that is made to the affected resource simultaneous or after the construction of the light well
is entirely one story.
LOT SIZE MAXIMUM
FLOOR AREA
BONUS
REQUESTED
FLOOR AREA
BONUS
5,982.3 S.F.250 S.F. 250 S.F.
To be considered for the bonus, it must be demonstrated that the project meets all of the following
criteria: MET NOT MET DOES NOT
APPLY
a) The historic building is the key element of the property, and the primary entry into the structure,
and the addition is incorporated in a manner that maintains the visual integrity of the historic
building; and
b) If applicable, historically significant site and landscape features from the period of significance of
the historic building are preserved; and the applicant is undertaking multiple significant restoration
actions, including but not limited to, re-opening an enclosed porch, re-installing doors and windows
in original openings that have been enclosed, removing paint or other nonoriginal finishes, or
removing elements which are covering original materials or features; and
c) The project retains a historic outbuilding, if one is present, as a free standing structure above
grade; and N/A
d) The applicant is electing a preservation outcome that is a high priority for HPC, including but not
limited to, creating at least two detached structures on the site, limiting the amount of above grade
square footage added directly to a historic resource to no more than twice the above grade square
footage of the historic resource, limiting the height of an addition to a historic resource to the height
of the resource or lower, or demolishing and replacing a significantly incompatible non-historic
addition to a historic resource with an addition that meets current guidelines.
MET
MET
MET
Review Criteria for 121 W. Bleeker
The applicant is requesting a 250 sf Floor Area Bonus for significant restoration efforts that include
re-opening the front porch and removing detrimental alterations to the historic resource.
The applicant may request up to 250 s.f. of floor area.
Summary of Review Criteria for Floor Area Bonus Request
26.415.110.F - Floor Area Bonus.
In selected circumstances, the HPC may grant up to five hundred (500) additional square feet of
allowable floor area for projects involving designated historic properties. The potential bonus is
determined by net lot area such that a 3,000-5,999 square foot lot is eligible for a maximum of a two
hundred fifty (250) square foot floor area bonus, a 6,000-8,999 square foot lot is eligible for a
maximum of a three hundred seventy five (375) square foot floor area bonus and a 9,000 square
foot or larger lot is eligible for a maximum of a 500 square foot floor area bonus. Floor area bonuses
are cumulative.
Page 3 of 3
Staff Finding: The applicant proposes to restore the historic resource by removing all non-
historic alterations and additions that encumber the resource. According to the 1904 Sanborn
Map, the resource appears to be in the same location but much of the south elevation has been
removed and replaced with additions that were not sympathetic to the historic resource. Staff
supports the proposed restoration efforts that include the opening of the front porch, removing the
non-historic dormers and side porch, and restoring missing architectural features using
photographic documentation. Staff recommends the applicant work with staff regarding the
accuracy of restoration details.
One of the criteria for granting a floor area bonus speaks to the importance of the historic entry
and the visual integrity of the resource. Staff finds the criteria will be met with the reopening of the
front porch and the proposed primary walkway that leads to the front entrance. Older photographs
show the details related to the porch prior to being enclosed.
Restoration is a priority for this project and a significantly incompatible addition that is
overwhelming the historic resource is to be demolished. The design shows much of the living
space is concentrated below grade with the use of large window wells to provide daylighting to
the subgrade space. The larger window wells are counted towards floor area calculations
according to the zoning calculations. Staff supports a floor area bonus for this design as
represented. Bonus floor area not used for this project will be forfeited.
Staff finds that the criteria for granting a floor area bonus are met with this revised design.