Loading...
HomeMy WebLinkAboutExhibit E Application.125 W Main St125 w main st | willis pember architects, inc | 412 n. mill st | aspen, co 81611 1.16.20        125 W MAIN COVER LETTER         To  Amy Simon  From  Willis Pember Architects  Subject  Relocation Land Use Application  Date  1.16.20    Dear Amy,    On behalf of the Ralli Dimitrius Trust we are pleased to present you with our Historic Preservation  Relocation Land Use Application.  As you know we are pursuing an ‘in‐situ’ relocation whose goal is  to minimize/eliminate any movement within the existing structure.  Our motivation for this is the  desire to renovate and expand the interior use of the structure from two stories with an  ‘uninhabitable’ basement to a fully habitable, three story structure with a full height basement.  To  accomplish this we have engaged the services of Evolve structural engineers who feel confident, as I  do, that the proposal is the best interest of the resource and by extension the historic preservation  goals of the City.    In order to achieve these goals we will request the following:    a. an FAR bonus of 250 SF. The reason for the full 250 FAR bonus request is the desire to preserve  the ability to convert the surface parking areas off of the alley into a full garage and connector at  some future date.  With this application 135SF of FAR is needed.  b. a side yard setback variance for work below grade at both East and West lot lines.   c. a variation in the residential design standards regarding the minimum size requirement of a light  well in a setback.  A fuller description can be found in the written description – history and  forensics, pgs 6‐7.    The additional and more conventional reason for theses requests is that the level of exterior  restoration we are planning will be of the highest order and will serve the community well to witness  the complete and utter transformation of this hidden gem of a home.    Lastly the owners’ have been apprised of the financial security requirements of this application and  are comfortable with the terms.      Best regards,          Willis Pember, AIA    City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet Agreement to Pay Application Fees An agreement between the City of Aspen ("City") and Property 'i% MI pimixlus'"r Phone No.: 323 216 6042 Owner ("I"): D-NI0DL - D(M US %ae Tk.NSff6 Email: � a . G0 Address of Billing Property: Address: 530 South lake ave, #433 (Subject of 125 n main street, (send bills here) Rasederra, CA 91101 application) Aspen, CO FA5ADLN p I understand that the City has adopted, via Ordinance No., Series of 2011, review fees for Land Use applications and payment of these fees is a condition precedent to determining application completeness. I understand that as the property owner that I am responsible for paying all fees for this development application. For flat fees and referral fees: I agree to pay the following fees for the services indicated. I understand that these flat fees are non-refundable. $ flat fee for $ flat fee for $ flat fee for $ flat fee for For Deposit cases only: The City and I understand that because of the size, nature or scope of the proposed project, it is not possible at this time to know the full extent or total costs involved in processing the application. I understand that additional costs over and above the deposit may accrue. I understand and agree that it is impracticable for City staff to complete processing, review and presentation of sufficient information to enable legally required findings to be made for project consideration, unless invoices are paid in full. The City and I understand and agree that invoices mailed by the City to the above listed billing address and not returned to the City shall be considered by the City as being received by me. I agree to remit payment within 30 days of presentation of an invoice by the City for such services. I have read, understood, and agree to the Land Use Review Fee Policy including consequences for no -payment. I agree to pay the following initial deposit amounts for the specked hours of staff time. I understand that payment of a deposit does not render and application complete or compliant with approval criteria. If actual recorded costs exceed the initial deposit, I agree to pay additional monthly billings to the City to reimburse the City for the processing of my application at the hourly rates hereinafter stated. $1,950.00 6.0 hrs $ deposit for hours of Community Development Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. $ deposit for hours of Engineering Department staff time. Additional time above the deposit amount will be billed at $325.00 per hour. City of Aspen: Property Owner: 11tc- PYi I P[tAk j'9MS psi b •1 �1nus Jessica Garrow, AICP Community Development Director Name: Qv/ -Nl W DIMI I US AS .�,S7f� Ralli Dimithus trust, P�4ie lu City Use: Fees Due: $_Received $ Title: ikUSTM City of Aspen 1130 S. Galena Street. 1 (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet ATTACHMENT 2 - Historic Preservation Land Use Application PRojECr: Name: Location: 125 West main Street, Lot C, Block 59 Aspen, CO 81611 (indicate street address. lot K block number or metes and bounds description of propert)') Parcel IDk (REQUIRED) 273707392007 Applicant: Name: Willis Pember, AIA Willis Pember Architects Address. 412 N. Mill Street, Aspen, CO Phone 0: Faxk: I; -mail: KEPRPSENTATI VE: Name: Address: Phone #: Fax#: Ti-PF. OF APPLICATION: (phwsc check all that apply): ❑ Historic Designation ❑ Relocation (temporary, on ❑ Certificate of No Negative Effect ❑ or off -site) ❑ Certificate of Appropriateness ❑ Demolition (total demolition) ❑ -Minor I listoric Development ❑ -Major Historic Development ❑ Historic Landmark Lot Split ❑ -Conceptual Historic Development ❑ -Final I Iistoric Development ❑ -Substantial Amendment EXISTING CONDITIONS: idescrintion of existine buildings. uses. nrevicus anorovals. etc.) Historic victorian built sometime between 1893 and 1895. Built and remains a single family home witfiiwoifoors an an in a iiabTo 5-as-e`mi6nt space. -- PROPOSAL: (description of proposed buildings uses, modifications, etc.) Interior renovation of upper two floors. Excavation and conversion of uninhabitable basement into —living space. Additional en suite bathrooms, new HVAC and kitchen relocation. Exterior improvements include new roofing, new exterior painting, at grade parking areas, demolished half -stair in side yard and landscape improvements. New windows in non -historic locations. City of Aspen1130 S. Galena Street. 1 (970) 920 5090 Historic land Use Application Requirements, Updated March 2016 City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet General Information Please check the appropriate boxes below and submit this page along with your application. This information will help us review your plans and, if necessary, coordinate with other agencies that may be involved. YES NO Does the work you are planning include exterior work; including additions, demolitions, new construction, remodeling, rehabilitation or restoration? r _ Does the work you are planning include interior work, including remodeling, rehabilitation, or restoration? Do you plan other future changes or improvements that could be reviewed at this time? In addition to City of Aspen approval for a Certificate of Appropriateness or No Negative Effect and a building permit, are you seeking to meet the Secretary of the Interior's Standards for Rehabilitation or restoration of a National Register of Historic Places Property in order to qualify for state or federal tax credits? If yes, are you seeking federal rehabilitation investment tax credits in Conjunction with this project? (Only income producing properties listed on the National Register are eligible. Owner -occupied residential properties are not.) i ; if yes, are you seeking the Colorado State Income Tax Credit for Historical Preservation? Please check all City of Aspen Historic Preservation Benefits which you plan to use: ❑ Rehabilitation Loan Fund Conservation Easement Program Dimensional Variances ❑ Increased Density Historic Landmark Lot Split Waiver of Park Dedication Fees 0 Conditional Uses Tax Credits [I Exemption from Growth Management Quota System City of Aspen 1130 S. Galena Street. 1 (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet ATTACHMENT 3 - Dimensional Requirements Form (Item #10 on the submittal requirements key. Not necessary for all projects.) Project: dimitrius residence Applicant: ralli dimitrius trust Project Location: 125 west main street Zone District: MU - mixed use Lot Size: 3,000 sf Lot Area: na (For the purposes of calculating Floor Area, Lot Area may be reduced for areas within the high water mark, easements, and steep slopes. Please refer to the definition of Lot Area in the Municipal Code.) Commercial net leasable: Existing: 0 Proposed: 0 Number of residential units: Existing: 1 -Proposed.--! Proposed % of demolition: +/- 15% tbd (small) DIMENSIONS: (write N/A where no requirement exists in the zone district) Floor Area: Existing: Allowable: 2,400sf Proposed: Height Principal Bldg.: Existing: 22'-11" Allowable: 28' Proposed. 22'-11" Accessory Bldg.: Existing: na Allowable: Proposed: On -Site parking: Existing: 2 Required: Proposed: 3 % Site coverage: Existing: Required: na Proposed: % Open Space: Existing: Required: na Proposed: Front Setback: Existing: 15'-5" Required: 10'-0" Proposed: 15'-5" Rear Setback: Existing: 5'-6" Required: 5' Proposed: 5'-6" Combined Front/Rear: Indicate N. S, E, W Existing: 15' Required: 15' Proposed: Side Setback: Existing: •7' w Required: 3'-0" Proposed: •7' Side Setback: Existing: 3'-0" a Required: 3'-0" Proposed: 3'-0" Combined Sides: Existing:-!- -7 Required: 6'-0" Proposed: 3.7' Distance between Existing: Required: Proposed: buildings: Existing non -conformities or encroachments and note if encroachment licenses have been issued: Home essentially built on west property line in 1890's. Historic lot split in 2015 established east side yard setback of 3'. Variations requested (identify the exact variances needed): a. west side yard setback (basement work) b. FAR bonus < 250SF c. egress well in setback - dimensional variance City of Aspen 11W S. Galen. Street. ( (pro) 920 SM Historic Land Use ApplicaWn 11seqvkwr*rft updats t + =1       PRE‐APPLICATION CONFERENCE SUMMARY    PLANNER:  Amy Simon, amy.simon@cityofaspen.com  DATE: July 3, 2019  PROJECT LOCATION:  125 W. Main Street  REQUEST:  Relocation of a Historic Landmark, Variations  REPRESENTATIVE:Willis Pember, willispa@comcast.net    DESCRIPTION: 125 W. Main Street is a landmarked property located within the Main Street Historic  District. The property was created through a historic landmark lot split approved in 2013 and the historic  structure is very close to the east and west property lines, a condition that was legalized through setback  variations granted in association with the lot split.    The property owner is interested in constructing a full height basement.  Rather than underpin the historic  foundation to accomplish this, the plan may be to build a new basement that is mostly disconnected from  the original foundation, inset some distance from those walls.  This work will require Relocation review by  the Historic Preservation Commission so that appropriate conditions which protect the historic resource  can be applied to the project.  Depending on the placement of the new basement, setback variations might  be requested.  The architect must confirm that the project will be within the allowed floor area, or request a  floor area bonus if appropriate.  Coordination with the Parks Department regarding potential impacts of  excavation to any adjacent trees will be needed.    The project is subject to design review and compliance with the Commercial, Lodging, and Historic District  Guidelines for Main Street, as well as the Historic Preservation Design Guidelines.    RELEVANT LAND USE CODE SECTIONS:  Section Number   Section Title  26.304     Common Development Review Procedures  26.415.090   Relocation of designated historic properties  26.415.110.C   Variations  26.575.020   Calculations and Measurements  26.710.180   Mixed Use (MU) zone district    For your convenience – links to the Land Use Application, Design Guidelines, and Land Use Code are  below:    Land Use Application  Land Use Code Historic Preservation Design Guidelines    Commercial Design Guidelines    Review by:   Staff for completeness and recommendation     HPC for decision  City Council for notice of the HPC decision.  Council has the  authority to remand the decision back to HPC for further  consideration.  Public Hearing:    Yes.   Neighborhood Outreach:  No.  Referrals: No fees will be charged, but the proposal will be referred to  Building, Zoning, Engineering and Parks for preliminary  comments.  Planning Fees:  $1,950for 6 billable hours of staff time. (Additional/ lesser hours  will be billed/refunded at a rate of $325 per hour.)  Total Deposit:   $1,950.00.    APPLICATION CHECKLIST: Below is a list of submittal requirements.       Completed Land Use Application and signed fee agreement.   Pre‐application Conference Summary (this document).   Street address and legal description of the parcel on which development is proposed to occur,  consisting of a current (no older than 6 months) certificate from a title insurance company, an  ownership and encumbrance report, or attorney licensed to practice in the State of Colorado,  listing the names of all owners of the property, and all mortgages, judgments, liens, easements,  contracts and agreements affecting the parcel, and demonstrating the owner’s right to apply for  the Development Application.   Applicant’s name, address and telephone number in a letter signed by the applicant that states  the name, address and telephone number of the representative authorized to act on behalf of  the applicant.   HOA Compliance form (Attached).   A written description of the proposal and an explanation in written, graphic, or model form of  how the proposed development complies with the review standards relevant to the  development application and relevant land use approvals associated with the property.   A proposed site plan and landscape plan.   Scaled drawings of all proposed structure(s) or addition(s) depicting their form, including their  height, massing, scale, proportions and roof plan; and the primary features of all elevations.   A site improvement survey (no older than a year from submittal) including topography and  vegetation showing the current status of the parcel certified by a registered land surveyor by  licensed in the State of Colorado.   An 8 1/2” by 11” vicinity map locating the parcel within the City of Aspen.   A written description and/or graphic illustrations of the building, structure or object proposed for  relocation.   A written explanation of the type of relocation requested (temporary, on‐site or off‐site) and  justification for the need for relocation.   A written report from a licensed engineer or architect regarding the soundness of the building,  structure or object, its ability to withstand the physical move and its rehabilitation needs, once  relocated.   Evidence of the financial ability to undertake the safe relocation, preservation and repair of the  building, structure or object; site preparation and construction of necessary infrastructure  through the posting of bonds or other financial measures deemed appropriate.      Once the application is deemed complete by staff, the following items will need to be submitted:     Total deposit for review of the application.   A digital copy of the application provided in pdf file format. Please provide text and graphics as  separate files.   12 sets of all graphics printed at 11x17.    Disclaimer:  The foregoing summary is advisory in nature only and is not binding on the City.  The summary is based on  current zoning, which is subject to change in the future, and upon factual representations that may or may not be  accurate.  The summary does not create a legal or vested right.                                                                              132 W. Main St. Ste. B Aspen, CO 81611 Phone: (970) 920-9299 Fax: (970) 920-5352 www.titlecorockies.com COMMITMENT TRANSMITTAL Commitment Ordered By: Karla Jacobs Alpine Bank 400 7th Street South Rifle, CO 81650 Phone: (970) 625-7050 Fax: email: karlajacobs@alpinebank.com Inquiries should be directed to: Susan Hass Title Company of the Rockies 132 W. Main St. Ste. B Aspen, CO 81611 Phone: (970) 920-9299 Fax: (970) 920-5352 email: shass@titlecorockies.com Commitment Number:0706189-C Reference: 1700007845 Borrower's Name(s):Ralli Dimitrius, Trustee f/b/o the Ralli Dimitrius Trust, u/d dated September 17, 1992 (Refinance) Property:125 W. Main Street, Aspen, CO 81611 Lot 1, Historic Landmark Lot Split of 125 W. Main Street, Pitkin County, Colorado COPIES / MAILING LIST Karla Jacobs Alpine Bank 400 7th Street South Rifle, CO 81650 Phone: (970) 625-7050 Fax: email: karlajacobs@alpinebank.com Final Documents Alpine Bank Central Loans 400 7th Street South Rifle, CO 81650 Phone: (970) 625-7020 Fax: (970) 668-9907 email: titlepolicy@alpinebank.com Doug Peate Alpine Bank 600 East Hopikins Avenue Aspen, CO 81611 Phone: (970) 429-2115 email: dougpeate@alpinebank.com Service Beyond Expectation in Colorado for: Eagle, Garfield, Grand, Pitkin and Summit Counties. (Limited Coverage: Jackson, Lake, Park and Routt Counties) Locations In: Avon/Beaver Creek, Basalt, Breckenridge, Grand Lake and Winter Park. (Closing Services available in Aspen and Glenwood Springs). Page 1 of 1 January 24, 2020 12:49 PM 132 W. Main St. Ste. B Aspen, CO 81611 Phone: (970) 920-9299 Fax: (970) 920-5352 www.titlecorockies.com Commitment Ordered By: Karla Jacobs Alpine Bank 400 7th Street South Rifle, CO 81650 Phone: (970) 625-7050 Fax: email: karlajacobs@alpinebank.com Inquiries should be directed to: Susan Hass Title Company of the Rockies 132 W. Main St. Ste. B Aspen, CO 81611 Phone: (970) 920-9299 Fax: (970) 920-5352 email: shass@titlecorockies.com Commitment Number:0706189-C Reference: 1700007845 Borrower's Name(s):Ralli Dimitrius, Trustee f/b/o the Ralli Dimitrius Trust, u/d dated September 17, 1992 (Refinance) Property:125 W. Main Street, Aspen, CO 81611 Lot 1, Historic Landmark Lot Split of 125 W. Main Street, Pitkin County, Colorado TITLE CHARGES These charges are based on issuance of the policy or policies described in the attached Commitment for Title Insurance, and includes premiums for the proposed coverage amount(s) and endorsement(s) referred to therein, and may also include additional work and/or third party charges related thereto. Owner’s Policy Premium: Loan Policy Premium: Additional Lender Charge(s): Additional Other Charge(s): Tax Certificate: Total Endorsement Charge(s): TBD Charge(s): TOTAL CHARGES: $1,957.00 $1,957.00 Service Beyond Expectation in Colorado for: Eagle, Garfield, Grand, Pitkin and Summit Counties. (Limited Coverage: Jackson, Lake, Park and Routt Counties) Locations In: Avon/Beaver Creek, Basalt, Breckenridge, Grand Lake and Winter Park. (Closing Services available in Aspen and Glenwood Springs). CM-2 (ALTA Commitment for Title Insurance (6-17-06)(WLTIC Edition (9/26/07) ALTA Commitment For Title Insurance (Adopted 06-17-06) (Revised 08-01-2016) COMMITMENT FOR TITLE INSURANCE ISSUED BY WESTCOR LAND TITLE INSURANCE COMPANY NOTICE IMPORTANT-READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT. THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION, OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION, ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY, AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED. THE COMPANY'S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT. THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY OTHER PERSON. COMMITMENT TO ISSUE POLICY Subject to the Notice; Schedule B, Part I-Requirements; Schedule B, Part II-Exceptions; and the Commitment Conditions, WESTCOR LAND TITLE INSURANCE COMPANY, a South Carolina Corporation (the “Company”), commits to issue the Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured. If all of the Schedule B, Part I-Requirements have not been met within six (6) months after the Commitment Date, this Commitment terminates and the Company's liability and obligation end. IN WITNESS WHEREOF, WESTCOR LAND TITLE INSURANCE COMPANY has caused its corporate name and seal to be hereunto affixed and by these presents to be signed in facsimile under authority of its by-laws, effective as of the date of Commitment shown in Schedule A. Issued By: WESTCOR LAND TITLE INSURANCE COMPANY The Title Company of the Rockies 132 W. Main Street, Suite B Aspen, CO 81611 Phone: (970) 920-9299 CONDITIONS The term mortgage, when used herein, shall include deed of trust, trust deed, or other1. security instrument. If the proposed Insured has or acquired actual knowledge of any defect, lien,2. encumbrance, adverse claim or other matter affecting the estate or interest or mortgage thereon covered by this Commitment other than those shown in Schedule B hereof, and shall fail to disclose such knowledge to the Company in writing, the Company shall be relieved from liability for any loss or damage resulting from any act of reliance hereon to the extent the Company is prejudiced by failure to so disclose such knowledge. If the proposed Insured shall disclose such knowledge to the Company, or if the Company otherwise acquires actual knowledge of any such defect, lien, encumbrance, adverse claim or other matter, the Company at its option may amend Schedule B of this Commitment accordingly, but such amendment shall not relieve the Company from liability previously incurred pursuant to paragraph 3 of these Conditions and Stipulations. Liability of the Company under this Commitment shall be only to the named3. proposed Insured and such parties included under the definition of Insured in the form of policy or policies committed for and only for actual loss incurred in reliance hereon in undertaking in good faith (a) to comply with the requirements hereof, or (b) to eliminate exceptions shown in Schedule B, or (c) to acquire or create the estate or interest or mortgage thereon covered by this Commitment. In no event shall such liability exceed the amount stated in Schedule A for the policy or policies committed for and such liability is subject to the insuring provisions and Conditions and Stipulations and the Exclusions from Coverage of the form of policy or policies committed for in favor of the proposed Insured which are hereby incorporated by reference and are made a part of this Commitment except as expressly modified herein. This Commitment is a contract to issue one or more title insurance policies and is not4. an abstract of title or a report of the condition of title. Any action or actions or rights of action that the proposed Insured may have or may bring against the Company arising out of the status of the title to the estate or interest or the status of the mortgage thereon covered by this Commitment must be based on and are subject to the provisions of this Commitment. The policy to be issued contains an arbitration clause. All arbitrable matters when5. the Amount of Insurance is $2,000,000 or less shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. You may review a copy of the arbitration rules at< http://www.alta.org/>. Westcor Land Title Insurance Company Joint Notice of Privacy Policy of Westcor Land Title Insurance Company and The Title Company of the Rockies Westcor Land Title Insurance Company (“WLTIC”) and The Title Company of the Rockies value their customers and are committed to protecting the privacy of personal information. In keeping with that philosophy, we each have developed a Privacy Policy, set out below, that will endure the continued protection of your nonpublic personal information and inform you about the measures WLTIC and The Title Company of the Rockies take to safeguard that information. This notice is issued jointly as a means of paperwork reduction and is not intended to create a joint privacy policy. Each company's privacy policy is separately instituted, executed, and maintained. Who is Covered We provide our Privacy Policy to each customer when they purchase a WLTIC title insurance policy. Generally, this means that the Privacy Policy is provided to the customer at the closing of the real estate transaction. Information Collected In the normal course of business and to provide the necessary services to our customers, we may obtain nonpublic personal information directly from the customer, from customer-related transactions, or from third parties such as our title insurance agent, lenders, appraisers, surveyors and other similar entities. Access to Information Access to all nonpublic personal information is limited to those employees who have a need to know in order to perform their jobs. These employees include, but are not limited to, those in departments such as closing, legal, underwriting, claims and administration and accounting. Information Sharing Generally, neither WLTIC nor The Title Company of the Rockies shares nonpublic personal information that it collects with anyone other than those individuals necessary needed to complete the real estate settlement services and issue its title insurance policy as requested by the consumer. WLTIC or The Title Company of the Rockies may share nonpublic personal information as permitted by law with entities with whom WLTIC or The Title Company of the Rockies has a joint marketing agreement. Entities with whom WLTIC or The Title Company of the Rockies have a joint marketing agreement have agreed to protect the privacy of our customer's nonpublic personal information by utilizing similar precautions and security measures as WLTIC and The Title Company of the Rockies use to protect this information and to use the information for lawful purposes. WLTIC or The Title Company of the Rockies , however, may share information as required by law in response to a subpoena, to a government regulatory agency or to prevent fraud. Information Security WLTIC and The Title Company of the Rockies, at all times, strive to maintain the confidentiality and integrity of the personal information in its possession and has instituted measures to guard against its unauthorized access. We maintain physical, electronic and procedural safeguards in compliance with federal standards to protect that information. The WLTIC Privacy Policy can be found on WLTIC's website at www.wltic.com COMMITMENT FOR TITLE INSURANCE Issued by as agent for Westcor Land Title Insurance Company SCHEDULE A Reference: 1700007845 Commitment Number: 0706189-C 1.Effective Date: January 10, 2020, 7:00 am Issue Date: January 24, 2020 2.Policy (or Policies) to be issued: ALTA Loan Policy (6-17-06)Policy Amount:$2,065,000.00 Premium:$1,957.00 Proposed Insured:Alpine Bank, its Successors and/or Assigns 3.The estate or interest in the land described or referred to in this Commitment is Fee Simple. 4.The Title is, at the Commitment Date, vested in: Ralli Dimitrius, Trustee f/b/o the Ralli Dimitrius Trust, u/d dated September 17, 1992 5.The land referred to in this Commitment is described as follows: FOR LEGAL DESCRIPTION SEE SCHEDULE A CONTINUED ON NEXT PAGE Countersigned The Title Company of the Rockies By: Mike Brudwick This page is only a part of a 2016 ALTA ® Commitment for Title Insurance issued by Westcor Land Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I-Requirements; and Schedule B, Part II-Exceptions. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Commitment for Title Insurance (8-1-2016) Technical Correction 4-2-2018 Schedule A Page 1 Commitment No: 0706189-C SCHEDULE A (continued) LEGAL DESCRIPTION The Land referred to herein is located in the County of Pitkin, State of Colorado, and described as follows: Lot 1, HISTORIC LANDMARK LOT SPLIT OF 125 W. MAIN STREET, according to the Plat thereof recorded December 6, 2013 in Plat Book 105 at Page 32 as Reception No. 606319, County of Pitkin, State of Colorado. This page is only a part of a 2016 ALTA ® Commitment for Title Insurance issued by Westcor Land Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I-Requirements; and Schedule B, Part II-Exceptions. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Commitment for Title Insurance (8-1-2016) Technical Correction 4-2-2018 Schedule A Page 2 Commitment No: 0706189-C COMMITMENT FOR TITLE INSURANCE Issued by Westcor Land Title Insurance Company SCHEDULE B, PART I Requirements The following are the requirements to be complied with prior to the issuance of said policy or policies. Any other instrument recorded subsequent to the effective date hereof may appear as an exception under Schedule B of the policy to be issued. Unless otherwise noted, all documents must be recorded in the office of the clerk and recorded of the county in which said property is located. All of the following Requirements must be met: 1.The Proposed Insured must notify the Company in writing of the name of any party not referred to in this Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then make additional Requirements or Exceptions. 2.Pay the agreed amount for the estate or interest to be insured. 3.Pay the premiums, fees, and charges for the Policy to the Company. 4.Documents satisfactory to the Company that convey the Title or create the Mortgage to be insured, or both, must be properly authorized, executed, delivered, and recorded in the Public Records. Statement of Authority for the Ralli Dimitrius Trust, u/d dated September 17, 1992, a California5. trust, evidencing the existence of said trust and the authority of one or more trustees to act on behalf of said trust, prior to the time that it encumbers title to subject property, and otherwise complying with C.R.S. 38-30.108.5, et seq. Deed of Trust from Ralli Dimitrius, Trustee f/b/o the Ralli Dimitrius Trust, u/d dated September6. 17, 1992, a California Trust to the Public Trustee of Pitkin County for the use of Alpine Bank, to secure $2,065,000.00. Exception No. 5 under Schedule B, Section II of this commitment will not appear in the policy or policies to be issued pursuant hereto, provided that (a) the documents contemplated by the requirements set forth in Schedule B, Section I of this commitment are submitted to and approved and recorded by the Company or its duly authorized agent, and (b) an examination of the records in the office of the County Clerk and Recorder by the Company or its duly authorized agent discloses that no defects, liens, encumbrances, adverse claims or other matters have been recorded This page is only a part of a 2016 ALTA ® Commitment for Title Insurance issued by Westcor Land Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I-Requirements; and Schedule B, Part II-Exceptions. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Commitment for Title Insurance (8-1-2016) Technical Correction 4-2-2018 Schedule B - Part I Page 3 Commitment No: 0706189-C in such records subsequent to the effective date hereof, and prior to the recording date of such recording(s). Exception No. 6 under Schedule B, Section II of this commitment will be amended in the policy or policies to be issued pursuant hereto, to read “Taxes and Assessments for the year 2019 and subsequent years". 24-MONTH CHAIN OF TITLE: The only conveyance(s) affecting said land recorded within the 24 months preceding the date of this commitment is (are) as follows: QuitClaim Deed to Ralli Dimitrius, Trustee f/b/o the Ralli Dimitrius Trust, u/d dated September 17, 1992 recorded June 27, 2008 as Reception No. 550590. NOTE: If no conveyances were found in that 24 month period, the last recorded conveyance is reported. If the subject land is a lot in a subdivision plat less than 24 months old, only the conveyances subsequent to the plat are reported. THE LIABILITY OF THE COMPANY UNDER THE POLICY TO BE ISSUED SHALL IN NO CASE EXCEED THE AMOUNT OF THE PROCEEDS OF THE LOAN SECURED BY THE INSURED MORTGAGE DISBURSED AT DATE OF POLICY PLUS THE AMOUNT OF EACH SUCCEEDING DISBURSEMENT THEREOF UNTIL THE AGGREGATE OF ALL DISBURSEMENTS IS EQUAL TO THE AMOUNT OF INSURANCE STATED IN SCHEDULE A, PLUS ANY AMOUNT ADVANCED TO PROTECT THE LIEN OF THE INSURED MORTGAGE AND SECURED THEREBY PLUS INTEREST ON SAID AMOUNTS, LESS ALL PAYMENTS ON SAID LOAN. This page is only a part of a 2016 ALTA ® Commitment for Title Insurance issued by Westcor Land Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I-Requirements; and Schedule B, Part II-Exceptions. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Commitment for Title Insurance (8-1-2016) Technical Correction 4-2-2018 Schedule B - Part I - continued Page 4 Commitment No: 0706189-C SCHEDULE B, PART II Exceptions THIS COMMITMENT DOES NOT REPUBLISH ANY COVENANT, CONDITION, RESTRICTION, OR LIMITATION CONTAINED IN ANY DOCUMENT REFERRED TO IN THIS COMMITMENT TO THE EXTENT THAT THE SPECIFIC COVENANT, CONDITION, RESTRICTION, OR LIMITATION VIOLATES STATE OR FEDERAL LAW BASED ON RACE, COLOR, RELIGION, SEX, SEXUAL ORIENTATION, GENDER IDENTITY, HANDICAP, FAMILIAL STATUS, OR NATIONAL ORIGIN. Schedule B of the policy or policies to be issued will contain exceptions to the following matters unless the same are disposed of to the satisfaction of the Company. Any loss or damage, including attorney fees, by reason of the matters shown below: Any facts, right, interests, or claims which are not shown by the Public Records but which could1. be ascertained by an inspection of said Land or by making inquiry of persons in possession thereof. Easements or claims of easements, not shown by the Public Records.2. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the3. Title that would be disclosed by an accurate and complete land survey of the Land. 4. Any lien, or right to a lien for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the Public Records. 5. Defects, liens, encumbrances, adverse claims or other matters, if any created, first appearing in the Public Records or attaching subsequent to the effective date hereof, but prior to the date of the proposed insured acquires of record for value the estate or interest or mortgage thereon covered by this Commitment. 6. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. Terms, agreements, provisions, conditions and obligations as contained in Ordinance No. 577. (Series of 1976) recorded November 11, 1976, in Book 319 at Page 456 as Reception No. 188864. This page is only a part of a 2016 ALTA ® Commitment for Title Insurance issued by Westcor Land Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I-Requirements; and Schedule B, Part II-Exceptions. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Commitment for Title Insurance (8-1-2016) Technical Correction 4-2-2018 Schedule B - Part II Page 5 Commitment No: 0706189-C Terms, agreements, provisions, conditions and obligations as contained in Ordinance No. 608. (Series 1976) recorded December 9, 1976, in Book 321 at Page 51 as Reception No. 189906. Terms, agreements, provisions, conditions and obligations as contained in Resolution #23, Series9. of 2013 by the Aspen Historic Preservation Commission Recommending Approval of an Application for a Historic Landmark Lot Split and Granting Approval for a Setback Variance for the Property Located at 125 W. Main Street, Lots C and D, Block 59, City and Townsite of Aspen, Colorado recorded July 19, 2013, at Reception No. 601520. Terms, agreements, provisions, conditions and obligations as contained in Ordinance No. 31,10. Series of 2013 by the City of Aspen approving a Historical Landmark Lot Split for the Property Located at 125 W. Main Street, Lots C and D, Block 59, City and Townsite of Aspen, Colorado recorded December 13, 2013 as Reception No. 606008. Terms, agreements, provisions, conditions and obligations as contained in Subdivision11. Exemption Agreement for 125 W. Main Street recorded December 6, 2013, at Reception No. 606318. Easements, rights of way and all other matters as shown on the Plat of Historic Landmark Lot12. Split of 125 W. Main Street, filed December 6, 2013, in Plat Book 105 at Page 32 as Reception No. 606319. THE LIABILITY OF THE COMPANY UNDER THIS POLICY SHALL IN NO CASE EXCEED THE AMOUNT OF THE PROCEEDS OF THE LOAN SECURED BY THE INSURED MORTGAGE DISBURSED AT DATE OF POLICY PLUS THE AMOUNT OF EACH SUCCEEDING DISBURSEMENT THEREOF UNTIL THE AGGREGATE OF ALL DISBURSEMENTS IS EQUAL TO THE AMOUNT OF INSURANCE STATED IN SCHEDULE A, PLUS ANY AMOUNT ADVANCED TO PROTECT THE LIEN OF THE INSURED MORTGAGE AND SECURED THEREBY PLUS INTEREST ON SAID AMOUNTS, LESS ALL PAYMENTS ON SAID LOAN. This page is only a part of a 2016 ALTA ® Commitment for Title Insurance issued by Westcor Land Title Insurance Company. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I-Requirements; and Schedule B, Part II-Exceptions. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Commitment for Title Insurance (8-1-2016) Technical Correction 4-2-2018 Schedule B - Part II - continued Page 6 Commitment No: 0706189-C DISCLOSURE STATEMENTS Note 1: Colorado Division of Insurance Regulations 3-5-1, Paragraph C of Article VII, requires that "Every Title entity shall be responsible for all matters which appear of record prior to the time of recording whenever the Title entity conducts the closing and is responsible for recording or filing of legal documents resulting from the transaction which was closed.” (Gap Protection) Note 2: Exception No. 4 of Schedule B, Section 2 of this Commitment may be deleted from the Owner's Policy to be issued hereunder upon compliance with the following conditions: The Land described in Schedule A of this commitment must be a single-family residence, which includes a1. condominium or townhouse unit. No labor or materials may have been furnished by mechanics or materialmen for purpose of construction on2. the Land described in Schedule A of this Commitment within the past 13 months. The Company must receive an appropriate affidavit indemnifying the Company against unfiled mechanic's3. and materialmen's liens. Any deviation from conditions A though C above is subject to such additional requirements or Information4. as the Company may deem necessary, or, at its option, the Company may refuse to delete the exception. Payment of the premium for said coverage.5. Note 3: The following disclosures are hereby made pursuant to §10-11-122, C.R.S.: The subject real property may be located in a special taxing district;(i) A certificate of taxes due listing each taxing jurisdiction shall be obtained from the County Treasurer or the(ii) County Treasurer's authorized agent; and Information regarding special districts and the boundaries of such districts may be obtained from the(iii) County Commissioners, the County Clerk and Recorder, or the County Assessor. Note 4: If the sales price of the subject property exceeds $100,000.00, the seller shall be required to comply with the disclosure or withholding provisions of C.R.S. §39-22-604.5 (Non-resident withholding). Note 5: Pursuant to C.R.S. §10-11-123 Notice is hereby given: (a)If there is recorded evidence that a mineral estate has been severed, leased or otherwise conveyed from the surface estate then there is a substantial likelihood that a third party holds some or all interest in oil, gas, other minerals, or geothermal energy in the property, and (b)That such mineral estate may include the right to enter and use the property without the surface owner's permission. Note 6: Effective September 1, 1997, C.R.S. §30-10-406 requires that all documents received for recording or filing in the clerk and recorder's office shall contain a top margin of at least one inch and a left, right and bottom margin of at least one-half inch the clerk and recorder may refuse to record or file any document that does not conform. Note 7: Our Privacy Policy: We will not reveal nonpublic personal customer information to any external non-affiliated organization unless we have been authorized by the customer, or are required by law. Note 8: Records: Regulation 3-5-1 Section 7 (N) provides that each title entity shall maintain adequate documentation and records sufficient to show compliance with this regulation and Title 10 of the Colorado Revised Statutes for a period of not less than seven (7) years, except as otherwise permitted by law. Note 9: Pursuant Regulation 3-5-1 Section 9 (F) notice is hereby given that “A title entity shall not earn interest on fiduciary funds unless disclosure is made to all necessary parties to a transaction that interest is or has been earned. Said disclosure must offer the opportunity to receive payment of any interest earned on such funds beyond any administrative fees as may be on file with the division. Said disclosure must be clear and conspicuous, and may be made at any time up to and including closing.” Be advised that the closing agent will or could charge an Administrative Fee for processing such an additional services request and any resulting payee will also be subjected to a W-9 or other required tax documentation for such Page 7 purpose(s). Be further advised that, for many transactions, the imposed Administrative Fee associated with such an additional service may exceed any such interest earned. Therefore, you may have the right to some of the interest earned over and above the Administrative Fee, if applicable (e.g., any money over any administrative fees involved in figuring the amounts earned). Note 10: Pursuant to Regulation 3-5-1 Section 9 (G) notice is hereby given that “Until a title entity receives written instructions pertaining to the holding of fiduciary funds, in a form agreeable to the title entity, it shall comply with the following: The title entity shall deposit funds into an escrow, trust, or other fiduciary account and hold them in a1. fiduciary capacity. The title entity shall use any funds designated as “earnest money” for the consummation of the transaction2. as evidenced by the contract to buy and sell real estate applicable to said transaction, except as otherwise provided in this section. If the transaction does not close, the title entity shall: Release the earnest money funds as directed by written instructions signed by both the buyer and seller;(a) or If acceptable written instructions are not received, uncontested funds shall be held by the title entity for(b) 180 days from the scheduled date of closing, after which the title entity shall return said funds to the payor. In the event of any controversy regarding the funds held by the title entity (notwithstanding any termination3. of the contract), the title entity shall not be required to take any action unless and until such controversy is resolved. At its option and discretion, the title entity may: Await any proceeding; or(a) Interplead all parties and deposit such funds into a court of competent jurisdiction, and recover court(b) costs and reasonable attorney and legal fees; or Deliver written notice to the buyer and seller that unless the title entity receives a copy of a summons(c) and complaint or claim (between buyer and seller), containing the case number of the lawsuit or lawsuits, within 120 days of the title entity's written notice delivered to the parties, title entity shall return the funds to the depositing party.” Page 8 Commitment No: 0706189-C Title Company of the Rockies Disclosures All documents received for recording or filing in the Clerk and Recorder's office shall contain a top margin of at least one inch and a left, right and bottom margin of at least one half of an inch. The Clerk and Recorder will refuse to record or file any document that does not conform to the requirements of this section. Pursuant to C.R.S. 30-10-406(3)(a). The company will not issue its policy or policies of title insurance contemplated by this commitment until it has been provided a Certificate of Taxes due or other equivalent documentation from the County Treasurer or the County Treasurer's authorized agent: or until the Proposed Insured has notified or instructed the company in writing to the contrary. Pursuant to C.R.S. 10-11-122. No person or entity that provides closing and settlement services for a real estate transaction shall disburse funds as a part of such services until those funds have been received and are available for immediate withdrawals as a matter ofright. Pursuant to C.R.S. 38-35-125(2). The Company hereby notifies the proposed buyer in the current transaction that there may be recorded evidence that the mineral estate, or portion thereof, has been severed, leased, or otherwise conveyed from the surface estate. If so, there is a substantial likelihood that a third party holds some or all interest in the oil, gas, other minerals, or geothermal energy in the subject property. Such mineral estate may include the right to enter and use the property without the surface owner's permission. Pursuant to C.R.S. 10-11-123. If this transaction includes a sale of property and the sales price exceeds $100,000.00, the seller must comply with thedisclosure/withholding requirements of said section. (Nonresident withholding) Pursuant to C.R.S. 39-22-604.5. Notice is hereby given that: The subject property may be located in a special taxing district. A Certificate of Taxes due listing each taxing jurisdiction shall be obtained from the County Treasurer or the County Treasurer's authorizedagent. Information regarding special districts and the boundaries of such districts may be obtained from the Board of County Commissioners, the County Clerk and Recorder, or the County Assessor. Pursuant to C.R.S. 10-11-122. Notice is hereby given that: Pursuant to Colorado Division of Insurance Regulation 8-1-2; "Gap Protection" -When this Company conducts the closing and is responsible for recording or filing the legal documents resulting from the transaction, the Company shall be responsible for all matters which appear on the record prior to such time or recording or filing; and "Mechanic's Lien Protection" - If you are the buyer of a single family residence, you may request mechanic's lien coverage to be issued on your policy of Insurance. If the property being purchased has not been the subject of construction, improvements or repairs in the last six months prior to the date of this commitment, the requirements will be payment of the appropriate premium and the completion of an Affidavit and Indemnity by the seller. If the property being purchased was constructed, improved or repaired within six months prior to the date of this commitment the requirements may involve disclosure of certain financial information, payment of premiums, and indemnity, among others. The general requirements stated above are subject to revision and approval by the Company. Pursuant to C.R.S. 10-11-122. Notice is hereby given that an ALTA Closing Protection Letter is available, upon request, to certain parties to the transaction as noted in the title commitment. Pursuant to Colorado Division of Insurance Regulation 8-1. Nothing herein contained will be deemed to obligate the Company to provide any of the coverages referred to herein unless the above conditions are fully satisfied. Page 9 Amy Simon, City of Aspen 9.05.19 Community Development, City of Aspen 120 Galena Street Aspen, CO 81611 RE: PID# 273707392007, 125 West Main Street, Lot C, Block 59 Consent from owner(s) to process application and authorizing the representative. Dear Amy, Please accept this letter as authorization for Willis Pember of Willis Pember Architects, Inc. to submit a Land Use Application on behalf of the property owners, Ralli Dimitirus Trust, pursuant to requirements for the Relocation of a Historic Landmark. If you require anything further, please advise. Very truly yours, F11tM DIMITPIws irvtsi Applicant: Ralli Dimitrius Trust Representative: Willis Pember Architects, Inc Nicole and Stirling Dimitrius Willis Pember 530 South Lake Ave, #433 412 N. Mill Street Pasedena, CA 91101 Aspen, CO, 81611 323 216 6042 vc 970 920 1727 vc willis pember architects, inc 412 n mill street I aspen, co 81611 1 970 920 1727 Homeowner Association Compliance Policy All land use applications within the City of Aspen are required to include a Homeowner Association Compliance Form (this form) certifying the scope of work included in the land use application complies with all applicable covenants and homeowner association policies The certification must be signed by the property owner or Attorney representing the property owner Name Ralli DiMM2�' s I-kv& i Property Owner ('(")- Email portroyaleent@yahoo.com Phone No 323-216-6042 Address of Property 125 West Main Street, Lot C, Block 59, City of Aspen (subject of application) I certify as follows (pick one) ® This property is not subject to a homeowners association or other form of private covenant. ❑ This property is subject to a homeowners association or private covenant and the improvements proposed in this land use application do not require approval by the homeowners association or covenant beneficiary. ❑ This property is subject to a homeowners association or private covenant and the improvements proposed in this land use application have been approved by the homeowners association or covenant beneficiary Evidence of approval is attached I understand this policy and I understand the City of Aspen does not interpret, enforce, or manage the applicability meaning or effect of private covenants or homeowner association rules or bylaws I understand that this document is a public document '(U �nLI Dim IVU-w&-r�J 4 Owner signature �� date KKLJ D MITi?Jus'XusT-, Evleo-T�. tt 'DIM lT)r-1us As TnGs1-6C- Owner printed name or. Attorney signature Attorney printed name date 1       Written Description – compliance with review standards    125 West Main Street  1.15.20    Review standards – part I     Historic Preservation Design Guidelines – Non‐relevant guidelines are grayed out.     Context  Chapter 1: Site Planning & Landscape Design    1.1 All projects shall respect the historic development pattern or context of the block,  neighborhood or district.  Response:  There is no change to the basic urban components of the site.  1.2 Preserve the system and character of historic streets, alleys, and ditches.  Response:  There is no change to the basic urban components of the site, including  ditches.  1.3 Remove driveways or parking areas accessed directly from the street if they were not part  of the original development of the site.  1.4 Design a new driveway or improve an existing driveway in a manner that minimizes its  visual impact.  Response:  We are designing a new driveway and plantings in an area at the rear of the  lot used for parking off of the alley.  1.5 Maintain the historic hierarchy of spaces.  Response:  There is no change to the basic components of the site.  1.6 Provide a simple walkway running perpendicular from the street to the front entry on  residential projects.  Response:  A simple concrete walkway exists and we propose leaving it as is.  1.7 Provide positive open space within a project site.  Response:  Despite the small lot size, positive open space exists at the front and rear of  the site.  1.8 Consider storm water quality needs early in the design process.    Response:  We have designed the drainage system met with the engineering dept.  1.9 Landscape development on Aspen Modern landmarks shall be addressed on a case by case  basis.   1.10  Built‐in furnishings, such as water features, fie pits, grills, and hot tubs, that could interfere   with or block views of historic structures are inappropriate.   1.11 Preserve and maintain historically significant landscaping on site, particularly landmark   trees and shrubs.  Response:  We are proposing to maintain historic lilacs and return open sod lawn via  judicious pruning and removal. We have met with the City Parks department.  1.12  Provide an appropriate context for historic structures.    Response:  That is the intent  2 1.13 Additions of plant material to the landscape that could interfere with or block views of      historic structures are inappropriate.  Response:  We are attempting to remove much of the offending, overgrown landscape.  1.14 Minimize the visual impacts of landscape lighting.  Response:  We are only adding landscape light to the rear yard, hidden in a hedge   adjacent to the new driveway. Ref. Landscape/Site plan. No landscape lighting is  proposed at the front of the house.  1.15 Preserve original fences.  Response: We are preserving all existing fencing.  1.16  When possible, replicate a missing historic fence based on photographic evidence.  1.17  No fence in the front yard is often the most appropriate solution.    Response:  ref. written description – history and forensics, pg 4.  1.18  When building an entirely new fence, use materials that are appropriate to the building   type and style.   Response:  We are proposing a contemporary, wood picket fence. Ref. site plan A1.0 at   the rear of the site.  1.19  A new fence should have a transparent quality, allowing views into the yard from the  street.  Response:  The proposed fence has various porosities depending on location, 30 and 55%  open. Ref. site plan A102.  1.20  Any fence taller than 42” should be designed so that it avoids blocking public views of   important features of a designated building.  Response:  Proposed fence rises to 6’‐0” where Molly Gibson pool area impacts home  privacy.  This is not a public view plane.  1.21  Preserve original retaining walls.  Response:  We are preserving a short front yard retaining wall. Not likely that it is  historic. ref. written description – history and forensics, pg 4.  1.22  When a new retaining wall is necessary, its height and visibility should be minimized.  1.23  Re‐grading the site in a manner that changes historic grade is generally not allowed and    will be reviewed on a case by case basis.          Response: Very little to no grading is anticipated. The site is relatively flat.  1.24  Preserve historically significant landscapes with few or no alterations.  Response: We intend to prune and preserve existing Lilacs to the west. Eliminating other  shrubs at the front yard will allow us to approach a historic restoration of the original  landscape. Relocation is internal to existing footprint.  1.25  New development on these sites should respect the historic design of the landscape and  its built features.   Response: Relocation will not affect the historic landscape.  1.26  Preserve the historic circulation system.   Response: No changes are proposed to the circulation system.  1.27  Preserve and maintain significant landscaping on site.  Response: Large trees in the front yard will remain. No tree removal or tree mitigation  will be proposed.      3 Rehabilitation  Chapter 2: Building Materials  2.1  Preserve original building materials.    Response: All original material will be preserved, wood re‐painted.   2.2  The finish of materials should be as it would have existing historically.  Response: No changes to finishes on historic piece. Painted wood will remain painted.  Asphalt shingles will remain asphalt. Metal roofing will remain non‐reflective.   2.3  Match the original material in composition, scale and finish when replacing materials on  primary surfaces.   Response:  This is the case on the historic structure. On the non‐historic structure, to  create a further distinction (ref. chapter 10) we propose  standing seam metal roof.  2.4  Do not use synthetic materials as replacements for original building materials.   Response: no synthetic materials are expected.  2.5  Covering original building materials with new materials is inappropriate.  Response: No historic materials will be covered over.  2.6  Remove layers that cover the original material.   Response: That situation doesn’t exist.    Chapter 3: Windows  3.1  Preserve the functional and decorative features of a historic window.   Response: All existing historic windows will be preserved and refurbished.  3.2  Preserve the position, number, and arrangement of historic windows in a building wall.   Response: No changes to the arrangement of historic windows or openings anticipated.  3.3  Match a replacement window to the original in its design.  Response: Only one replacement window anticipated in a historic opening. Returning to  a double hung from a modern casement.  3.4  When replacing an original window, use materials that are the same as the original.   Response: Yes, the replacement window will be wood.  3.5  Preserve the size and proportion of a historic window opening.   Response: Opening size will remain the same.  3.6  Match, as closely as possible, the profile of the sash and its components to that of the  original window.   Response: We will use the simplest (square) profiles supplied by Loewen.  3.7  Adding new openings on a historic structure is generally not allowed.  Response: We propose replacing several modern casement windows from the historic  and non‐historic portions of the resource and aligning these with preservation goals  enumerated elsewhere.  3.8  Use a storm window to enhance energy conservation rather than replace a historic  window.   Response: Where storm panels make sense, they’ll be used on the interior.            4 Chapter 4: Doors   4.1  Preserve historically significant doors.  Response: The historic front door will be re‐used. The rear door on the non‐historic  addition, is likely a re‐purposed back‐door from the original 1890’s construction and will  be refurbished. A non‐historic side door will be replaced in the same dimensions.  4.2  Maintain the original size of a door and its opening.   Response:  No changes to door opening dimensions are planned.  4.3  When a historic door or screen door is damaged, repair it and maintain its general historic  appearance.  Response: The rear door will require extensive restoration; the glazing has been  corrupted with cheap plastic inserts and other inappropriate materials.  4.4  When replacing a door or screen door, use a design that has an appearance similar to the  original door or a door associated with the style of the building.  Response: The side door will appear like a simple, secondary and plainly detailed historic  door.  4.5  Adding new doors on a historic building is generally not allowed.  4.6  If energy conservation and heat loss are concerns, use a storm door instead of replacing a  historic entry door.   Response: Storm doors are not anticipated at this time.  4.7  Preserve historic hardware.  Response: Front door historic hardware will remain unchanged. A non‐historic door bell  will be replaced. Back door will reuse historic hardware and introduce a contemporary,  secure keypad for rental guests.    Chapter 5: Porches & Balconies  5.1  Preserve an original porch or balcony.  Response: That is the intent. Non‐historic stair treatments will be removed at the porch  stairs.   5.2  Avoid removing or covering historic materials and details.   Response: All original materials will be used here.  5.3  Enclosing a porch or balcony is not appropriate.  5.4  If reconstruction is necessary, match the original in form, character and detail.  Response: An accurate reconstruction of the porch guardrail has already occurred, circa  early 2000’s.   5.5    If new steps are to be added, construct them out of the same primary materials used on  the original, and design them to be in scale with the porch or balcony   Response: The existing front stairs will be reused and refurbished.   5.6   Avoid adding handrails or guardrails where they did not exist historically, particularly  where visible from the street.  Response: A minimal code required handrail is proposed on one side of the stair,  eliminating the confusing, non‐historic detailing currently in place.          5 Chapter 6: Architectural Details  6.1  Preserve significant architectural features.   Response: No loss of historic detail is anticipated.  6.2  When disassembly of a historic element is necessary for its restoration, use methods that  minimize damage to the original material.  6.3  Remove only the portion of the detail that is deteriorated and must be replaced.  6.4  Repair or replacement of missing or deteriorated features are required to be based on  original designs.  Response: Nothing needs to be replaced, except perhaps some exterior window sills  which may have been covered over with flat trim.  They will be managed on a case‐by‐ case basis.    6.5  Do not guess at “historic” designs for replacement parts.   Response:  There is nothing to guess at in our proposal.     Chapter 7: Roofs  7.1  Preserve the original form of a roof.  7.2  Preserve the original eave depth.  7.3  Minimize the visual impacts of skylights and other rooftop devices.  Response: Our replacement skylight maintains its existing low profile at the rear of the  property.  7.4  New vents should be minimized, carefully, placed and painted a dark color.   Response: A Historic brick chimney  will remain, non‐historic vents removed and new  vents will be biased towards the rear of the property and painted black.  7.5  Preserve original chimneys, even if they are made non‐functional.    Response: There is one and we anticipate reusing.  7.6  A new dormer should remain subordinate to the historic roof in scale and character.  7.7  Preserve original roof materials.  Response: We propose replacing asphalt with asphalt as the existing roof is at the end of  its useful life. New asphalt will have the same scale as the oldest layer we can discover  on under the existing roof.  7.8  New or replacement roof materials should convey a scale, color and texture similar to the  original.   Response: That is the intent – see above.  7.9  Avoid using conjectural features on a roof.   Response: None anticipated.  7.10  Design gutters so that their visibility on the structure is minimized to the extent possible.  Response: We are replacing existing gutter and downspouts on the west property  boundary. They will not look like they are from Alpine Ace or the Miners building, but will  be custom fabricated.     Chapter 8: Secondary Structures ‐ NA        6 Chapter 9: Excavation, Building Relocation and Foundations  9.1  Developing a basement by underpinning and excavating while the historic structure  remains in place may help to preserve the historic fabric.   Response: This is the purpose of this relocation application. No disturbance to the  existing foundation is expected, while creating a stronger more resilient structure.  9.2  Proposals to relocate a building will be considered on a case‐by‐case basis.   Response: This relocation application doesn’t require movement of the building.  9.3  Site a relocated structure in a position similar to its historic orientation.   Response: The structure will remain in its historic orientation throughout construction.  9.4  Position a relocated structure at its historic elevation above grade.   Response: The historic resource is not being moved.  9.5  A new foundation shall appear similar in design and materials to the historic foundation.   Response: There is no new foundation proposed, only repair of the existing stone.  9.6  Minimize the visual impact of lightwells.  Response: The lightwell is located in a very tight side yard behind a fence, inaccessible to   sight lines from the front or rear yards.  9.7  All relocations of designated structures shall be performed by contractors who specialize in  moving historic buildings, or can document adequate experience in successfully relocating such  buildings.  Response: Our builder, Rudd construction is a certified to work on Historic buildings in  City of Aspen and has worked on many historic projects previously.  9.8  Proposals to relocate a building to a new site are highly discouraged.    Chapter 10: Building Additions  10.1  Preserve an older addition that has achieved historic significance in its own right.  Response: The addition is not historic. In our limited scope we have attempted to follow  the applicable guidelines of chapter 10.  10.2  A more recent addition that is not historically significant may be removed.   Response: There is no change to the footprint of this project, including the addition.  10.3  Design a new addition such that one’s ability to interpret the historic character of the  primary building is maintained.  Response: Through redesign of the addition openings, and material changes (roof) we  have created a dialogue that clearly allows the addition to be read as ‘other’.  10.4  The historic resource is to be the focus of the property, the entry point, and the  predominant structure as viewed from the street.    Response: There is no change proposed to the hierarchy of the structure.  10.5  On a corner lot, no portion of an addition to a one story historic resource may be more  than one story tall, directly behind that resource, unless completely detached above grade by a  distance of at least 10 feet  10.6  Design a new addition to be recognized as a product of its own time.  Response: The proportioning of the addition windows (floor to ceiling) and roofing  material speaks directly to this provision.  10.7  When planning an addition to a building in a historic district, preserve historic alignments  on the street.    7 10.8  Design an addition to be compatible in size and scale with the main building.  Response: Not really applicable‐ the addition mass already exists.  10.9  If the addition is taller than a historic building, set it back from significant façades and use  a “connector” to link it to the historic building.  10.10‐10.12 not relevant    Chapter 12: Accessibility, Architectural Lighting, Mechanical Equipment, Services Areas, &  Signage    12.1  Address accessibility compliance requirements while preserving character defining  features of historic buildings and districts.   Response: As a private residence, we are not required to make the home accessible.  12.2  Original light fixtures must be maintained. When there is evidence as to the appearance of  original fixtures that are no longer present, a replication is appropriate.    Response: No historic exterior fixtures remain. Wall mounted fixtures will be removed  from the resource.  12.3  Exterior light fixtures should be simple in character.  Response: Proposed light fixtures are simple and clean.  12.4  Minimize the visual impacts of utilitarian areas, such as mechanical equipment and trash  storage.  Response: Trash is located behind a fence in the side yard and not visible from the street  or alley. Ref. Site Plan.    12.5 ‐12.9 not relevant                                        End part I – Historic Preservation Guidelines    8               Written Description – Compliance with review standards    125 West Main Street  Review standards – part II     Commercial, Lodging and Historic Design Guidelines for Main Street  Building Placement     3.1 Orient a new building or addition to the street  Response:  There is no new addition or new building as part of the scope, NA.    Architecture    3.2 Design a new structure to be recognized as a product of its time.  Response:  The scope of work is restricted to preservation of an existing asset with a non‐historic  addition to the rear.  3.3 The imitation of older historic styles blurs the distinction between old and new buildings  and is discouraged.  Response:  There is no imitation, simply a desire to create more historic accuracy.    Building Proportion, Scale, Height and Width  3.4 Roof forms should be in character with surrounding historic buildings.     Response:  There is no new architecture, NA.    3.5 Roof forms should be in character with surround historic buildings  Response:  There is no new architecture, NA.    3.6 Design a front elevation to be similar in scale to historic buildings in the district  Response:  There is no new architecture, or change in scale to the front.    3.7 Clearly define the primary entrance to a new building with a front porch or similar feature.  Response:  There is no new architecture, simply and existing front porch, NA.    3.8 Design an addition to be compatible in size and scale with the main building.  Response:  There is no new addition, NA.  9     3.9 When planning an addition to a building in a historic district, preserve historic alignments on  the street.  Response:  There is no new addition, NA.    Details and Materials     3.10 Use building components that are similar in size and shape to those of the Victorian‐era  residences seen traditionally on Main Street  Response:  Changes to the historic structure attempt to restore the Victorian language of the  original and remove poor, non‐historic alterations implemented since the late 1890’s. Ref.  elevations A301, A302 , A303 and written description, history and forensics text for complete  summary.    3.11 Architectural details should reinforce the historic context of the block.  Response:  Modification of details on the resource attempts to restore the historic character lost  due to thoughtless changes from the 80’s. These include:    a. Guardrail/Newel/Handrails on the front porch stairs are overly ornate and do not relate  to the historic porch guardrail language.  Referencing the 70’s photo suggests that many  Victorians had few if any guardrails, or handrails at the sides of the stair.  We are  proposing eliminating the ornate, non‐historic ‘turned’ profiles of the stairway and  replacing with a minimal, modern steel handrail profile to the east side of the stair.  b. Please reference ‘history and forensics’ pgs. 3‐4‐5 for a fuller explanation of changes to  the front porch guardrail over the last 50 years.    3.12 Primary materials should be wood or brick  Response:  There is no change to the primary material palette, NA.    3.13 Secondary materials should relate to the historic context.  Response:  There are no secondary material changes, except on the rear of the house. We are  proposing to change the roofing material of a non‐historic addition from asphalt shingles to  standing seam metal to further separate history of the pieces and parts of the development.    3.14 Use roofing materials that are similar in appearance to those seen historically.  Response:  We are maintaining the same roofing material on the historic parts of the project.       End part II, Commercial, Lodging and Historic Design Guidelines for Main Street    AL HOTEL ASPEN': PIP .'"# r• 25 *41 • 'f�st f,j 0I l�g� MOLLY GIBSUH LODGE ppo fig • - Y � N Paepcke Park AMMI&A V� • r j January 13, 2019 Willis O. Pember, AIA Willis Pember Architects, Inc 412 North Mill Street Aspen, Colorado 81611 RE: Existing Historic Residence Remodel & Relocation Application – 125 W Main Street -- Aspen, Colorado Willis, As requested, we visited the above site on October 1, 2019 and we have reviewed the architectural design intent for the remodel of the existing residence at the site. The extent of the remodel includes interior reconfiguration at the upper and main levels and the addition of a new basement in the existing crawl space. As a part of the proposed work, structural elements will be reviewed and retrofitted as needed to accommodate the reconfigured interior spaces. Selective strengthening of rafters and floor joists is expected. The proposed basement footprint has been laid out in a way to minimize the impact to the existing foundations and new foundation elements will be designed to provide lateral bracing of the existing foundations in lieu of the current crawl space grade configuration. Observations during the above noted site visit indicate that the structure will be well served by the proposed remodel. Once demolition can begin, the interior wall and ceiling finishes shall be at least partially removed to allow further observation of the existing structural system. We shall be contacted to perform a site observation of the exposed structure to determine correlation with assumed conditions and make any necessary structural revisions. This shall be done prior to proceeding with the removal or modification of any framing members. Should you have any further questions regarding this matter, please feel free to contact our office. Sincerely, Evolve Structural Design LLC Steven R. Edmiston, P.E., S.E. Senior Engineer Please note that the opinions expressed herein are based on limited, non-intrusive observations and that no analyses were conducted to verify compliance of the structure with current building codes or other standards. These opinions may change if other conditions are discovered. 01/13/2020 HVAC ducts 1      Written Description       125 West Main St – Relocation             1.15.20  Owner:  Ralli Dimitrius Trust   Architect:  Willis Pember Architects  Structural Engineer:  Evolve Structural Design, Steve Edmiston  Civil Engineer:   Woody Creek Engineering, Josh Rice  Mechanical Engineer:   Climate Control     History and Forensics  The home was built between 1890 and 1893 based on the Sanborn Map data base.  The Sanborn  map plan of block 59 from 1893 is the home’s first appearance in the records and remains the  same on all subsequent Sanborn maps we could find; no out buildings or historic additions appear  to have been added in the 19thC.  Of particular note is the location of a porch in the initial  construction at the SE corner of the house which is absent in the reading of the existing home.  No  clues are evident in the details of the exterior siding nor are any clues given from the interior that  a porch was there.  Following the infilling of the rear porch, a 224 SF non‐historic slab‐on‐grade  addition was added to the rear of the envelope roughly the same width of the porch and  extending south, sometime in  70’s judging by the appearance of the  5‐1/2” framing and the contemporary windows.                                                                                                                                                                    125 West Main. 1893 Sanborn, Block 59                     view of non‐historic addition 2019                                   2                                   PORCH                                     NON –HISTORIC       ADDITION      The composite image above shows an overlay of the Sanborn drawing over WPA’s plan of the  existing house.  The Sanborn map is highly accurate and shows the break between the historic back  porch in the home’s interior in the middle of the modern strip casement window proposed for  replacement.  Interior demolition of this wall indicated nothing unusual in the framing, or  indication of a historic window opening that had been covered over.   The studs and exterior  sheathing appear to be original to the 19thC.  A rusted metal flue collar remains in the wall.                                                                                                                                                   Interior drywall demo – 2019 east  kitchen wall.  No historic framed  openings revealed.        3                              1975 – City of Aspen files    The earliest reference image for the front of the house is from a 1970’s photo provided to the  applicant by the City.  Given what little activity there was in Aspen during the quiet years, it is not  unreasonable to suggest the front of the house, as pictured below, is historically intact.  In any  case, this is what we have to work with.    The landscape is a simple lawn with ornamental shrubs and hollyhocks around the edges.  We will  attempt to restore the largely overgrown condition of the current landscape to this very simple  and restrained place albeit through the lenses of the Parks Department’s 2020 tree policies.                            4                                                    1985 – City of Aspen files      By 1985, the date of the next earliest image, certain obvious changes have taken place; the details  of the porch guardrail are now a rhythm of turned wooden posts, replacing the rectilinear pattern  of sticks seen in the 1975 photo.  Additionally, over scaled newel posts with gigantic wood balls  and a heavy wood handrail were added to the front steps.  All other detailing appears to be  unchanged ‐ windows, porch supports and brackets and the front door – are all what appears  today.  The steel or cast iron fence on the low masonry retaining wall is located at the front  property line. It would seem to be from the 1890’s as the latching and detail of the metal is very  old but likely installed in the 1980’s.  That the front yard fence does not appear in the 1975 photo  suggests it was a 1980’s ‘retro’ upgrade as the perspectives and depth of field of the ’75 and ’85  photos are nearly identical.  It would be hard to photo the front of the home in 1975 w/o seeing a  portion of the fence if it were actually there in 1975.      Lilac bushes on the east and west sides of the front yard now appear much larger after 10 years.              5                                                2019 – Front Elevation    Sometime in the early 2000’s the property was cited for ‘demolition by neglect’ by the City. This  was confirmed by Amy and Sarah Adams separately.  The porch was falling off the front of the  house. The owner did reinforce the structure of the porch as it seems now to be sound.  Remediation of the main house foundation also took place.  Additionally it is my assumption that   at this time the porch guardrail design was returned back to what it was before the turned  spindles appeared in the 1985 photo as the porch guardrail design today reflects the 1975 photo.  The front steps with the heavy newel posts and handrails however, remain as a remnant of the  well intended but misguided 80’s work and is rotted.                                             Non‐historic element   6    Proposal                                       125 West Main St ‐ Relocation  Prior to submittal the following meetings took between the following City agencies and the design  team.  a. Parks Department  b. Engineering Department  c. Building Department  d. Planning and Zoning  e. Historic Preservation    North Side – street facing facade    a. Remove rotting and heavy newel posts and handrails from the 80’s. Replace with a minimal  steel handrail (3/8”x2” section) on just the east side of the steps, enough to satisfy IRC and  Aspen building codes.   Victorian homes historically did not often provide handrails at entry  steps. Ref. A300 Elevations and photo of house in 1975.  b. Repair and restore any and all wood parts of the porch, guardrail, columns and decorative  brackets.  c. Simplify landscape, prune and remove much of the overgrown vegetation – ref. landscape  plan.  Re‐sod front yard.  d. Supplement existing porch ceiling lights.  Add wall scone/entry light at the front door – ref.  lighting plan and specs.  e. Retain ‘old’ looking cast iron fence at the property line. It is there and is continuous with  the adjacent lot that was split from this property.       East Side – side yard     a. Eliminate non‐historic side porch on the east side of the house. The side porch roof was  removed as part of the lot split.  The footprint does not appear on the Sanborn maps and is  non‐historic.  Along with this we propose to retain a non‐operable door on this elevation  that had previously accessed the side porch for interior daylighting.   b. Add a new fence along the side yard separating and shielding this house from approved  Molly Gibson pool enclave.  Ref. landscape plan.   c. Add an egress window well under the Eastlake bay window that is 36” deep but is  proposed to be wider than the guidelines require in order to respect the historic alignment  of the basement opening and the width of a ‘fancy’ bay window above.  Variance Request.  d. Replace two 20th C, non‐historic windows with those that comply with the guidelines.   Ref. A301.  One is a code required bedroom egress window in the former location of the  kitchen.    7                                                            Historic Bay window aligned with opening below           Partial East Elevation                                                         VARIANCE REQUEST     Partial Main Floor Plan       8    South Side – rear yard    a. Replace one 20th C, non‐historic window with one that complies with the guidelines in the  non‐historic addition. Ref. A302.  b. Replace and slightly relocate skylight in roof of non‐historic addition.  c. Eliminate non‐historic wall sconce.  d. Add new fence along property line. Ref. landscape/Site Plan A102.  e. Create three parking spaces. Add pervious parking surface in place of weeds and gravel.                Ref. Landscape/Site Plan A102.  f. Refurbish and paint historic looking back door. Replace colored glass in surround.   g. Glaze basement window in historic opening in stone foundation wall.  h. Replace non‐historic cracked wood post at rear entry roof with a 4” painted steel structural  column.                                   Cracked structural column   West Side – side yard    a. Replace gutter and downspouts.  b. Add new window to non‐historic addition per guidelines for additions.  c. Replace non‐historic Pella casement window in a historic opening with a wood double  hung.  d. Glaze basement window in historic opening in stone foundation wall.  e. Remove non‐historic wall sconce at former side stairway.      Roofs    a. Re‐roof all roofs. Peel back all layers of built‐up asphalt shingles to structural sheathing.   Apply waterproof underlayment to all.  b. Non‐historic addition roof, and east side bay window roof to be clad in non‐reflective black  metal roofing, 16” standing seam wide at main roofs, sheet metal on bay window.    c. All two story roofs and historic front porch roof to be black asphalt shingles, verify the  historic scale of the tabs.  Restore and refurbish any metal ornamentation, if it exists at  ridgelines.  Basement - view towards Main St historic basement foundation wall with recent concrete underpinning 125 WEST MAIN STREET RELOCATION willis pember architects aspen, co, S 1611 970 920 1727 r' Jar: Recent underpinning towards front half of house Adopted Codes & Standards The following codes as amended by Ordinance 40, 2016 • 2015 IRC (International Residential Code) Chapters 1-10 + 2015 IRC appendixes: E: Manufactured homes, F: Radon, 1: Existing Buildings & 5tructure s, H: Patio Covers, K: Sound Transmission. • 2015 IPC (International Plumbing Code) 2015 IMC (International Mechanical Code) 2015 IFGC (International Fuel Gas Code) • 2015 IECC (International Energy Conservation Code) ■ 2015 1FC (International Fire Code) • 2015 IEBC(international Existing Building Code) • 2015 ISPSC (International Swimming Pool and Spa Code) ■ 2015 ISEP (International Solar Energy Provisions) • 2014 NEC (National Electrical Code) (will adopt the 2017 when the State of Colorado adopts) GENERAL NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO STARTING WORK, SHOULD A DISCREPANCY OCCUR WITHIN THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND THE EXISTING CONDITIONS, NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION. 2. DO NOT SCALE DRAWINGS.DIMEN SIONS SHALL TAKE PRECEDENCE OVER SCALE OF DRAWINGS. 3. SHOULD A DISCREPANCY OCCUR WITHIN THE CONSTRUCTION DOCUMENTS, CONTRACTOR TO CONTRACT ARCHITECT FOR DIRECTION. 4. SHOULD A DISCREPANCY OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS SHALL TAKE PRECEDENCE, 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION AT THE SITE. 6. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS, AND THE CONTRACT DOCUMENTS. 7. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN AND ORDERLY CONDITION EACH SUBCONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF WORK SHALL REMOVE ALL DEBRIS AS A RESULT OF THEIR WORK. 8. NO PORTION OF WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SHOP DRAWING OR SAMPLE HAS BEEN REVIEWED BY THE ARCHITECT, OWNER AND/OR STRUCTURAL ENGINEER AND APPROVED. 9. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, EQUIPMENT, CLOSET RODS, MEDICINE CABINETS AND ALL OTHER ITEMS AS REQUIRED. 10, PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS, ATTIFCS, ETC VERIFY LOCATION WITH ARCHITECT PRIOR TO INSTALLATION. 11. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS RELATED TO THIS WORK. CONTRACTOR TO VERIFY WITH CITY OF ASPEN BUILDING DEPARTMENT FOR ANY PARKING RESTRICTIONS RELATIVE TO CONSTRUCTION TRAFFIC. 12, RADON, SMOKE, AND CARBON MINOXIDE DETECTORS AS REQUIRED BY CODE AND CITY OF ASPEN CODE. 13, CONTRACTOR IS TO COMPLY WITH IECC 2009. HISTORIC PRESERVATION NOTES 1. SAMPLES OF NEW MATERIALS WILL BE CREATED FOR REVIEW AND APPROVAL BY H.P.C. STAFF AS REQUESTED.. 2. NEW ROOF PENETRATIONS SHALL BE REVIEWED BY HPC AT TIME OF HEARING. 3. OTHER HPC CONDITIONS REQUIRED AS PART OF THE APPROVALS, 4. LANDSCAPE, EXTERIOR LIGHTS FIXTURES AND MATERIAL SELECTIONS TO BE REVIEWED AT HEARING. 6i 125 WEST MAIN STREET - 1975 25 WEST MAI N LOTS C + D, CITY AND TOWNSITE OF ASPEN PITKIN COUNTY, COLORADO DRAWING FIST A 000 COVER IMAGE + DRAWING LIST Z 001 INDEX & CHECKLIST Z-002 APPROVALS Z-003 APPROVALS 7-004 SCOPE, APPROVALS & SUMMARY Z 005 SITE PLAN Z-005.1 SITE PLAN LIGHTING Z-005.2 SITE PLAN LIGHTING 7-006 RDS CHECKLIST 7-007 DEMO CALCULATIONS Z 008 FLOOR PLANS Z-009 ROOF PLAN OVER SITE PLAN Z-010 FLOOR AREA CALCS 7-011 HEIGHT INFORMATION SURVEY—SOPRIS ENGINEERING C200 BASINS C300 GRADING AND DRAINAGE PLAN C400 UTILITIES C500 DETAILS C600 EROSION SEDIMENT CONTROL PLAN L100 LANDSCAPE DEVELOPMENT PLAN L200 PLANTING PLAN + FENCE DESIGN L300 LIGHTING PLAN L500 LIGHTING SPECS A102 SITE PLAN A103 FAR PROPOSED A104 FAR EXISTING A105 FIRE AREA PLAN A200 BASEMENT LEVEL A201 GROUND LEVEL PLAN A202 UPPER LEVEL PLAN A203 ROOF PLAN A301 ELEVATIONS PROPOSED + EXISTING A302 ELEVATIONS PROPOSED + EXISTING A303 ELEVATIONS PROPOSED + EXISTING A401 SECTIONS A402 SECTIONS A601 ASSEMBLIES A602 ASSEMBLIES, DETAILS A603 STAIR DETAILS A604 DETAILS A701 KITCHEN A702 BATHROOMS A703 BATHROOMS A704 LIVING ROOM A801 DOOR AND WINDOW SCHEDULE E101 LOWER LEVEL ELECTRICAL E201 MAIN LEVEL ELECTRICAL E202 UPPER LEVEL ELECTRICAL D201 FLOOR PLAN — DEMO D202 FLOOR PLAN — DEMO EX 200 EXISTING BASEMENT LEVEL PLAN EX 201 EXISTING — MAIN LEVEL PLAN EX 202 EXISTING — UPPER LEVEL PLAN EX 401 EXISTING — SECTION E—W EX 402 EXISTING SECTION N S M0.1 COVER SHEET M0.2 EQUIPMENT SCHEDULE M1.1 BASEMENT LAYOUT M1.21 MAIN LEVEL SUPPLY M2.0 MAIN LEVEL SYSTEM M3.0 UPPER LEVEL SYSTEM S0.001 GENERAL NOTES + TYP. DETAILS S2.001 FOUNDATION PLAN S2.002 MAIN LEVEL FRAMING S2.003 UPPER FLOOR FRAMING S2.004 ROOF FRAMING S6.001 DETAILS S6.002 DETAILS COVER SHEET NOTES FOR PLANNING APPROVAL EVERY PAGE OF EVERY APPROVAL IS PRINTED ON SHEETS 7-002 & 7-003 'APPROVALS' AS REQUIRED P11 D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER n/a MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ROARING FORK VALLEY 970 945 2326 ANDY SILVERMAN 970 384 4627 GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.28.19 D.D. 10.23.19 HPC: 1.15.20 PROGRESS: 11.2.19 PERMIT SUBMITTAL: CONSTRUCTION: CHANGE ORDER (OVER SHEET PROJECT # 1904 FILENAME: 1904 AOOO S1 5 ° 4 4 ' 1 7 " W 10 0 . 0 0 10 0 . 0 0 N1 5 ° 4 4 ' 1 7 " E S74° 15' 43"E 30.00' N74° 15' 43"W 18.57' S 3 5 ° 5 5 ' 0 7 " E 2 5 7 . 6 4 ' N79° 13' 41"W 1834.77' S1 5 ° 4 4 ' 1 7 " W 2 5 . 4 2 S1 5 ° 4 4 ' 1 7 " W 5 9 . 0 8 N74° 15' 43"W 14.43 S1 5 ° 4 4 ' 1 7 " W 1 5 . 5 0 S74° 15' 43"E 3.00' N79° 13' 41"W 1834.77' 11.2 9. 4 5.1 6. 0 11.6 32 . 1 1.1 18 . 5 8.6 2. 9 3.2 2. 015.0 42 . 4 0.57' 30.38' 20.92' 15.47' 21.01' 3-3.5"x7' 4-4.5"x9' 3-4.75"x9' 2-4.2"x8' 4-4"x8' 5.6"x11'2"x4' 2"x4' 2"x4'2"x4' 2"x4' 4"x8' 4.8"x10' 15.9"x30' 11.5"x22' 6"x12'7.1"x14' 9.9"x20' 2.5"x5'7.2"x14' 6-2"x24' XGAS XG A S XGAS XG A S XGAS XGA S XGAS XG A S XEL XEL XEL XE L XEL XEL XEL XEL XTV XT V XTV XT V XUT XU T XUT XU T TWO STORY WOOD FRAME HOUSE WITH BASEMENT COVERED ENTRY COVERED ENTRY LOT A LOT 1 0.069 Acres ± 3,000 SQFT ± COVERED PORCH STEPS STEPS RETAINING WALL W/ IRON FENCE LOT M LOT B LOT FLOT E LOT O LOT PLOT K LOT L LOT N MAIN STREET BLOCK 59 (ASPHALT SURFACE) ADJOINING PROPERTY WOOD PRIVACY FENCE GRAVEL PARKING CONCRETE SIDEWALK CONCRETE CURB & GUTTER CONCRETE WALK CO N C R E T E W A L K ALLEY FOUND NO. 5 REBAR AND PLASTIC CAP L.S. #12707 FOUND NO. 5 REBAR & PLASTIC CAP L.S. #12707 PROJECT BENCHMARK GATE SIGN GPS - 6 CENTERLINE OF S. GARMISCH ST. & E. HOPKINS AVE GPS - 7 CENTERLINE OF S. SIXTH ST. & W. HOPKINS AVE (T I E ) (TIE) FOUND NO. 5 REBAR & PLASTIC CAP L.S. #28643 FOUND NO. 5 REBAR & PLASTIC CAP L.S. #28643 100.00' ROW WIDTH 1S T S T R E E T 75 . 4 5 R O W W I D T H UNLANDSCAPED SURFACE 7894 78 9 4 7 8 9 5 78 9 4 78 9 4 78 9 5 7894 FOUND NO. 5 REBAR & PLASTIC CAP L.S. #28643 BEARS S62°37'30"W, 0.22'7894 7 8 9 4 FOUND NO. 5 REBAR & PLASTIC CAP L.S. 19598 FOUND NO. 5 REBAR & PLASTIC CAP L.S. 19598 3' WITNESS CORNER SET NO. 5 REBAR & PLASTIC CAP L.S. 28643 FOUND NO. 5 REBAR & PLASTIC CAP L.S. 19598 BEARS N55°27'29"W, 0.15' FOUND NO. 5 REBAR & PLASTIC CAP L.S. 19598 BEARS N31°23'16"W, 0.43' 3' SIDEYARD SETBACK, SEE NOTE NO. 12 10' FRONTYARD SETBACK 5' SIDEYARD SETBACK 5' REARYARD SETBACK 3' SIDEYARD SETBACK SEE NOTE NO. 12 5' REARYARD SETBACK IMPROVEMENT SURVEY PLAT OF: SHEET 1 OF 1 125 W. MAIN STREET LOTS C & D, CITY AND TOWNSITE OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO NOTES 1.DATE OF SURVEY: APRIL 16, 2013 AND JULY 31, 2019. 2.DATE OF PREPARATION: MAY, 2013 AND JULY - SEPTEMBER, 2019. 3.BASIS OF BEARING: A BEARING OF N 38°05'44" W ESTABLISHED BY GPS OBSERVATIONS BETWEEN NGS MONUMENTS S-159 & Q-159 UTILIZING THE CITY OF ASPEN CONTROL MONUMENTATION MAP, PREPARED BY MARCIN ENGINEERING LLC, DATED DECEMBER 2, 2009, THIS ESTABLISHED A SITE BEARING BASE OF S 74°15'43" E BETWEEN THE SOUTHWEST CORNER OF BLOCK 58, MONUMENTED BY A FOUND #5 REBAR & PLASTIC CAP L.S. #25947 AND THE SOUTHEAST CORNER OF BLOCK 58, MONUMENTED BY AN "X" IN CONCRETE. THE ASPEN TOWNSITE BLOCK BEARINGS (S 75°09'11" E AND S 14°50'49" W) HAVE BEEN ROTATED 0°53'28" CLOCKWISE, TO BE CONSISTENT WITH THE RECORDED PLAT. 4.BASIS OF SURVEY: THE OFFICIAL MAP OF THE CITY OF ASPEN, PREPARED BY G.E. BUCHANAN, DATED DECEMBER 15, 1959; CITY OF ASPEN GPS CONTROL MONUMENTATION MAP PREPARED BY MARCIN ENGINEERING LLC, DATED DECEMBER 2, 2009; THE IMPROVEMENT SURVEY PLAT PREPARED BY SOPRIS ENGINEERING, WITH A DATE OF APRIL 16, 2013; THE HISTORIC LANDMARK LOT SPLIT OF 125 W. MAIN STREET RECORDED DECEMBER 6, 2013 AS PLAT BOOK 105 AT PAGE 32, RECEPTION NO. 606319; VARIOUS DOCUMENTS OF RECORD, AND THE FOUND MONUMENTS, AS SHOWN. 5.THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH BY SOPRIS ENGINEERING, LLC (SE) TO DETERMINE OWNERSHIP OR EASEMENTS OF RECORD. FOR ALL INFORMATION REGARDING EASEMENTS, RIGHTS OF WAY AND/OR TITLE OF RECORD, SE RELIED UPON THE ABOVE SAID PLATS DESCRIBED IN NOTE 4, AND THE TITLE COMMITMENT PREPARED BY TITLE COMPANY OF THE ROCKIES - ASPEN DIVISION, FILE NUMBER 0706012-C, EFFECTIVE DATE OF JULY 16, 2019. 6.PITKIN COUNTY PARCEL NO. 273512455065. 7.ACCORDING TO THE FLOOD INSURANCE RATE MAP NUMBER 08097C0203C (JUNE 4, 1987) THE SUBJECT PROPERTY IS NOT WITHIN A FLOOD ZONE. 8.SAID DESCRIBED PROPERTY IS IN A SLOPE PERCENTAGE CATEGORY OF 0-20% (OR LESS), ACCORDING TO THE PERCENT SLOPE MAP, PREPARED JULY 1, 2009 BY ASPEN PITKIN GIS. 9.SAID DESCRIBED PROPERTY IS NOT WITHIN THE MUD FLOW ZONES, ACCORDING TO THE 2014 CITY OF ASPEN URBAN RUNOFF MANAGEMENT PLAN (FIGURE 7.1a) AND OUTSIDE THE POTENTIAL GEOLOGICAL HAZARD ZONES, ACCORDING TO THE 2001 CITY OF ASPEN MASTER DRAINAGE PLAN (FIGURE ES-5). 10.BASIS OF ELEVATION: THE CITY OF ASPEN CONTROL DATUM, WHICH IS BASED ON AN ELEVATION OF 7720.88' (NAVD 1988) ON THE NGS STATION "S-159". THIS ESTABLISHED A SITE BENCHMARK ELEVATION OF 7894.1' ON A FOUND NO. 5 REBAR WITH A 1.25" PLASTIC CAP (L.S. 12707) MONUMENTING THE NORTHWEST CORNER OF THE SUBJECT PROPERTY, SHOWN HEREON. 11.CONTOUR INTERVAL: ONE (1) FOOT. 12.PER RESOLUTION NO. 23 OF 2013, RECORDED JULY 19, 2013 AS RECEPTION NO. 601520, THE EAST SIDEYARD SETBACK HAS BEEN REDUCED BY TWO FEET (2'). NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. SOPRIS ENGINEERING - LLC CIVIL CONSULTANTS 502 MAIN STREET, SUITE A3 CARBONDALE, COLORADO 81623 (970) 704-0311 GRK 19179 9/30/2019 G:\2019\19179 125 W. MAIN ASPEN\SURVEY\Survey DWGs\Working Base Dwgs\19179 ISP 13047 UPDATE.dwg VICINITY MAP SCALE: 1" = 2000' DECIDUOUS TREE (TRUNK DIAMETER" X DRIPLINE') CONIFEROUS TREE (TRUNK DIAMETER" X DRIPLINE') EDGE OF VEGETATION LIGHT POLE ELECTRIC TRANSFORMER ELECTRIC PEDESTAL TELEPHONE PEDESTAL CATV PEDESTAL EXISTING CONDITIONS LEGEND 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 SITE IMPROVEMENT SURVEY PLAT I, GEOFFREY R. KELLER, HEREBY CERTIFY TO RALLI DIMITRIUS, TRUSTEE F/B/O THE RALLI DIMITRIUS TRUST, U/D DATED SEPTEMBER 17, 1992 AND THE TITLE COMPANY OF, THAT THIS IS AN “IMPROVEMENT SURVEY PLAT” AS DEFINED BY C.R.S. § 38-51-102(9), AND THAT IT IS A MONUMENTED LAND SURVEY SHOWING THE CURRENT LOCATION OF ALL STRUCTURES, WATER COURSES, WATER FEATURES AND/OR BODIES OF WATER , ROADS, VISIBLE UTILITIES, FENCES, OR WALLS SITUATED ON THE DESCRIBED PARCEL AND WITHIN FIVE FEET OF ALL BOUNDARIES OF SUCH PARCEL, ANY CONFLICTING BOUNDARY EVIDENCE OR VISIBLE ENCROACHMENTS, AND ALL EASEMENTS AND RIGHTS OF WAY OF A PUBLIC OR PRIVATE NATURE THAT ARE VISIBLE, OR APPARENT, OR OF RECORD AND UNDERGROUND UTILITIES DESCRIBED IN TITLE COMPANY OF THE ROCKIES - ASPEN DIVISION'S TITLE INSURANCE FILE NO. 0706012-C, OR OTHER SOURCES AS SPECIFIED ON THE IMPROVEMENT SURVEY PLAT. ________________________________ GEOFFREY R. KELLER L.S. #37997 PROPERTY DESCRIPTION LOT 1, HISTORIC LANDMARK LOT SPLIT OF 125 W. MAIN STREET RECORDED DECEMBER 6, 2013 AS PLAT BOOK 105 AT PAGE 32 RECEPTION NO. 606319 CITY OF ASPEN COUNTY OF PITKIN STATE OF COLORADO GAS METER PR:3.0 AREA:173.3 SF gutter 1 PR:3.1 AREA:173.3 SF gutter 2 PR:3.2 AREA:195.3 SF PR:2.0 AREA:236.5 SF PR:2.1 AREA:121.4 SF PR:2.2 AREA:151.3 SF gutter 3 PR:2.3 AREA:320.6 SF PR:2.4 AREA:238.8 SF PR:1.3 AREA:203.5 SF PR:1.0 AREA:532.8 SF PR:1.4 AREA:552.4 SF PR:1.1 AREA:38.6 SF PR:WW1 AREA:18.9 SF PR:1.2 AREA:43.6 SF DISCHARGE BASIN PR:2.4 DOWNSPOUT TO PAVERS DISCHARGE BASIN PR:3.0 TO YARD REPLACE CURB & GUTTER IF DAMAGED DURING CONSTRUCTION El e v a t i o n Station Pipe A PROFILE 7892 7893 7894 7895 -0+020+00 0+25 0+50 0+75 0+84 CONCRETE PAVERS MIN 3 1 8" FOR VEHICULAR TRAFFIC NO. 8, 89, OR 9 AGGREGATE BETWEEN JOINTS BEDDING COURSE MIN 2" NO. 8 AGGREGATE NO. 8 STONE MIN 6" BELOW PIPE 10/18/2019 DATE OF PUBLICATION C0.0 COVER SHEET RA L L I D I M I T R I U S TR U S T 12 5 W M A I N S T . , A S P E N 11/15/2019 HPC WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, COLORADO 81656 (P): 970-429-8297 WOODYCREEKENGINEERING.COM C200 GRADING & DRAINAGE PLAN 0 5 10 20 40 Scale: 1" = 10' N EXISTING CONTOUR PROPOSED CONTOUR7910 PROPERTY LINE CONCRETE LEGEND BUILDING ROOF OUTLINE LOWER LEVEL OUTLINE WALL NOTES: 1. GUTTERS AND DOWNSPOUTS SHALL BE UTILIZED FOR BASINS PR:3.0, PR:3.1 AND PR:2.2. 2. INTERNAL DRAIN SYSTEM FOR PR:2.4 SHALL DISCHARGE TO PAVERS. 3. BASIN PR:2.0 SHALL SHEET FLOW TO FRONT YARD. 4. ALL OTHER BASINS SHALL SHEET FLOW TO INLETS 1-5. I (�y COATROOM 107 GAS KITCHEN 1n 105 � I I 00 00 00 00 LAUNDRY 1.5" MEXICAN BLACK BEACH Fl 0-81 ROCK INFILL BETWEEN CONC. PLANKS. \ I Ir I SITE BUILT CONCRETE PAVING STRIPS 12"x6"x8'OR16'. REF. - CIVIL FOR DRAINAGE PROFILE. I I / I I ALLEY I I PATH LIGHT FIXTURE 'K', TYR. FOR THREE I L!tj Lf�l I I— — — — — — — —— — —— — — —�— — — — — — -I (__B SITE IMPROVEMENTS — NEW PERVIOUS DRIVEWAY l OV 1 /4" - 1 9 - 0" 8'-01, 180WA. go] 8'-01, 1x6 PAINTED WOOD BOARDS 2x2 PAINTED WOOD BOARDS i i I i r� I I I ELEVATION 4x4 PAINTED WOOD POSTS Qi (-Di PROPERTY LINE PLAN �Ln I i i i I I I I I I I I I I I I i I I I I I i i i I I I I B SITE IMPROVEMENTS —NLW FENCE ON EAST PROPERTY LINE II I 10 1 /299 - 1 9-099 I I I i i i I i i i PROPERTY LINE RESTORE METAL' EXISTING BRICK . FENCE AND RETAINING WALL' ENTRY GATE. PRUNE 50% OF/ % REMOVE OVER 4.8 x10 o OVERGROWN i ASPEN GROWN 1 LILAC BUSH MULTI STEMED o sal I • I EXIS!ITNG MAPLE AND j •;• LILAC SHRUBS LILAC LOW FENCE I , _.—�_._._._..._._._._ _.-._.-._.- .-.-.-.-:-._.-._.-.-.-.-..._.-. ._ 6-2"x24' 15.9"x30' � j I / � i SPRUCE i P- I 42 MAPLE AND i I i LILAC SHRUB 7.1 "x14' j ASPEN FRONT YA; x12 i I , ASPEN CLEAN DEADFALL, PRUNE AND TIGHTEN • ----------------------------- CANOPIES. I .. I I � i • I • i ---� i WHERE CRABTREE AND MOUNTAIN ASH I � - ----- ---- -I BLOCK PROPERTY CORNER, (AND NOT I ON SUBJECT PROPERTY) PROVIDE 1 i i ' PROTECTION DURING CONSTRUCTION. I I I i I i • i PROPERTY LINE I � I ON eax80 WHERE SPRUCE -- I i i OVERHANGS PROPOSED ROOF PROVIDE 'J EGRESS WELL. 6' CLEARANCE. -- j I I j I 35.5°% 78.75° i PROVIDE MULCH N AREAS TOO �I � I DARK FOR SOD. I I I I -� r --y CONCRETE PAD I s --t -- UNDER \00 I i J CONDENSERS El I i I O _- ON 60X80 INFILL MEXICAN BEACH ROCK IN � I NARROW STRIP I I I I • I I I I ' BUILDING L�___�� i SETBACK i 1 1 I I I ❑ i I i i L_J I i j i i I I I i i i I I I i i I i j I j I i I FUTURE MOLLY GIBSON j I ! GAS i OUTDOOR POOL j I AREA I j °° j I • i i I i i j i o 1 i i FENCE I i i i I LAVE 2'X1 19599 i I ii I i PERVIOUS I ii i PAVING FOR LANDSCAPE NOTES: IL - ! THREE PARKING A. FRONT YARD: RESTORE SPACES. LANDSCAPE, RE —SOD AND E IRRIGATE. INSTALL DRIP o ii IRRIGATION. LOW FENCE B. BACK YARD: PARKING AREA PARKING #2-8'X19' PARKING #3-8'X19' 42" PERVIOUS PAVERS, SITE BUILT CONCRETE. EXISTING FENCE C. NEW FENCE ALONG EASTERN NOT DRAWN (3) THREE SURFACE PARKING SPOTS PROPERTY LINE, SEE B/102. PLANTING STRIP. 2'X36' i i i A SITE PLAN 10 3/16" 1 ' 0" 21,p1 ALLEY i i D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER NA MECHANICAL CONSULTANT DESIGN -BUILD BY RUDD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.29.19 H PC: PROGRESS: PERMIT SUBMITTAL: 9.21.19 CONSTRUCTION: CHANGE ORDER SITE PLAN PROJECT # 1904 FILENAME: 1904 A 2 I I i I i II 3 I I o o o ACCESSIBLE WATER TAP L L4 -- -- --- --- --- STREET TACIN❑ EXEMPT --`I E3P❑RCH / AREA = 169,0 SF — D I M I T R I U S I ENT ° a — _ ALL PAIOED DE K W eGLGHGHT - -- RESIDENCE o DDE W Sax I B-D G5'LG HGHT B R00 -4"CLG HGHT I 20 125 WEST MAIN STREET ALL❑WABLE SUBGRADE r °H -„-2' T ASPEN, CO 81611 N WA WNi SW1 RL OR" ECAESS CALCULATI❑N71 N I WDGFLD � I I PARCEL ID # 273707392007 _ UNDERPIN STONE WALL o BASEMENT CEILING ° OR M LEL N. BAC LA AT LNNDOW OPENING OPE —YES O J 6 C ITER D FRI BELV O d HEIGHTS C❑NSTANT SX< r'N12 .2. O W N E R S 2 g I X/T(F) = C - — NCH 7 203 2 L _ — J RALLI DIMITRIUS TRUST F= 1 J 0 9 6 5 9 G S F 530 SOUTH LAKE AVENUE #433 T = 1 2 6 5 0 4 S F STAR �' OGNT. GUARD 208 HAN°RAIL STAIR o PEN RISER — — ---� PASADENA CA 91101 ° F SH LO o - 3 X 3 0 7 2 4 G S F TH �� OPEN FLOW W 0 TREAD 2D5 9TAR ❑PENING HW L 95,14SF 4R;/I G ss7// � II 307,24/1 265,04 = 2428% EXP❑SED A NT ALL+ ILIN — J PAI W DWO WO FL R GR❑SS AREA = O - � CONSULTANT S — — — o O 2428% X 1 J096,59 2D EAYE ORAC N RAM 103&56SF-95,14SF 00 LO FS REVEES B°°KPH UPPER LEVEL 266.25 SF FAR LOWER FAR 943.42 LEVEL ( EXISTING 871.85 SF) SIDE ❑PEN DECK AREA ARCHITECT o ° WILLIS PEMBER ARCHITECTS, INC ADDI➢ON ABOVE — — 37,10 SF 412 N. MILL ST. L ASPEN, CO NEW KriINT _ CONTACT: WILLIS PEMBER p LOWER MAIN FIN. FLOOR _0EL. 97'-6"0 (V) 970 920 1727 J GAS N❑N—STREET FACING 0 STRUCTURAL ENGINEER PORCH AREA = 3042 SF ° EVOLVE ENGINEERING _________2,._6„a._______________ s 1040 MAIN STREET s CARBONDALE, CO 81623 I i WNDW 0� 4' 12� o CONTACT: SARA MICKUS (970) 618 7708 m o m EXP❑SED EXISTING MAIN LEVEL GR❑SS SF = 1,308,04 SF WALL AREA � I 245,59 SF T❑TAL N❑N—EXEMPT P❑RCH AREA 3❑,42 SF SURVEYOR i 60,17 SF SOPRIS ENGINEERING — PR❑P❑SED MAIN LEVEE GROSS SF = 1,324,73 SF 502 MAIN ST, STE A3 D' TOTAL N❑N—EXEMPT PERCH AREA = 3❑,42 SF CARBONDALE, CO 81623 WNDW CONTACT: MARK BECKLER EXP❑SED B UPPER LEVEL FL❑❑R AREA CALCULATI❑NS A MAIN LEVEL FL❑❑R AREA CALCULATI❑NS (V) (970) 704-0311 WALL AREA FAR 1/8" = 1'-0" FAR 1/8" = 1'-0" LANDSCAPE ARCHITECT 2 376�22 S� 79,49 SF NORTH NA 3/B' —�------"-------CIVIL ENGINEER — WOODY CREEK ENGINEERING, LLC P.O. BOX 575 EXP ❑SED WOODY CREEK, CO 81656 WALL AREA CONTACT: JOSH RICE 3 131,14 SF 25,53 SF 970 309 7130 4 — —6='--- — SOILS ENGINEER i TBD i m; C X P ❑SED MECHANICAL CONSULTANT m' WALL AREA DESIGN -BUILD BY RUDD 462.10 S 144 7 S F , FLOOR AREA SUMMARY GENERAL CONTRACTOR - - - - °=°-- - - - MAIN LEVEL AREA: 17324.73 1,308.04 EXIST RUDD CONSTRUCTION ; _+- UPPER LEVEL AREA: 943.42 871.85 EXIST 132 PARK AVENUE BASALT, CO 81621 EXPOSED BASEMENT LEVEL: 266.25 (HABITABLE) SCOTT DURYEA WALL AREA VO 970 618 7200NTACT: 5 125,02 SF 26,34 SF TOTAL FAR 2,534.40 (2,179.89 EXIST) 134.40 SF BONUS REQUIRED EGRESS ISSUE: 0i o WNDW EXP❑SED S.D. 7.19.19 m WALL AREA 6 164.77SF HPC 1.15.20 PROGRESS: — 5 8 0 5 SF MAX ALLOWABLE FAR IS .8 TO 1 OR 2,400SF per R6. PERMIT SUBMITTAL: CONSTRUCTION: I i - MAX ALLOWABLE DECK AREA is 15% of MAX FAR or 360SF. CHANGE ORDER i m EXP❑SED 6 5 SS EXISTING) REMAININGFAR = 12 1 F(220.11 F EXI TINmWALL AREA — 710.5 SF 2,85 SF Mixed Use Zone District in Land Use Code section 26.710.180.D.11.c.i, Floor FLOOR AREA Area Ratio (FAR). CAUS PROPOSED —I I Detached residential and duplex dwellings established prior to the adoption of I PROJECT # 1904 m mi EXPOSED Ordinance No. 7, Series of 2005 receive 100% of the allowable floor area of an FILENAME: 1904 WALL AREA 8 equivalent -sized lot located in the R-6 Zone District.) 14919 S� — 40,34 SF C SUB GRADE CALCULATI❑N FAR 1/8" = 1'-0" I I I I L- I I L_ 0' 4' 12' I I I �S.O.G ABOVE I I J BASEMENT C❑NSIDER UNINHABITABLE (per C❑A) EAR = 0 N❑NSTREET F P❑RCH AREA - 30 PR❑P❑SED MAIN LEVEL GR❑SS SE = 1,324,73 SE STAIR ❑PENING 16,69SF = 1,308,04 T❑TAL N❑NEXEMPT P❑RCH AREA = 3❑,42 SUB GRADE CALCULATI❑N 1/8" = 1'-0" I T FACING EXEMPT AREA = 169,0 SF HISTORIC WALL TYPE SF SF ADDITION WALL TYPE 04' 12' UPPER LEVEL FLEER AREA CAUCUUATI❑NS 1/8" = 1'-0" FLOOR AREA SUMMARY MAIN LEVEL AREA: UPPER LEVEL AREA: BASEMENT LEVEL: TOTAL FAR NORTH 1,308.04 871.85 0.00 (UNINHABITABLE) 2,179.89 STAIR ❑PENING 28,98SF SE DJF1 D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 GROSS AREA = CONSULTANTS 90479SF-2898SF= UPPER LEVEL 875.81 SF) 0' 4' MAIN LEVEL EL❑❑R AREA CALCULATI❑NS 1/8" = 1'-0" ARPHIT11I WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY RUDD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 MAX ALLOWABLE FAR IS 1:1 OR 2,400SF per R6. HP(: I.I5.20 I� PROGRESS: MAX ALLOWABLE DECK AREA is 15% of MAX FAR or 360SF. PERMIT SUBMITTAL: CONSTRUCTION: CHANGE ORDER REMAINING FAR = 220.11 SF Mixed Use Zone District in Land Use Code section 26.710.180.D.11.c.i, Floor Area Ratio (FAR). Detached residential and duplex dwellings established prior to the adoption of Ordinance No. 7, Series of 2005 receive 100% of the allowable floor area of an equivalent -sized lot located in the R-6 Zone District.) FLOOR AREA (ALICS EXISTING PROJECT # 1904 FILENAME: 1904 Al 04 1 A401 3 A401 1 9' 4 1 /8" _ V1 -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- -.- I j I , I j i I I �i i I I � I I ; N ; I i o I � I 1 i - o-------- 5-6----I---I- - ^ o' �o o \ Iv, \ I , I CLOSET I I I I WIND 0 W \ STAIR I I I ; - o X \ Q ill II \ \ II I o o. _ _ _ __ __ _ - LL-------- i L-- i UTILITIY CASEWORK BELOW BED NEW CONC. SLAB CHASE PLATFORM NEW CONC. FOOTING 2'-11 1/8" 11BUNKROOM I� i0 �I VERIFY 003 BUNKROOM SECTION — VIEW EAST 1 / ^ 99 - ^ 9 - O 99 Q ------------------4-8 5/8"------- Q ------------- 14'- 0 3/8" -- --------------- w ------------------------------------------------- 11'-8 3/8" 13 10 �/4" Ii i I i I OPEN STORAGE SHELVES 42SF ACCESSIBLE WATER TAP � I I F - - - - - - - - �I I , HVAC I MECH. RM I I 001 2'-0" HW F------ - - - - -- ----------- 4 TWIN 39x75 TWIN I 39x75 1� -- - - - - ----------- -- ==-=_ --J -- 001 � 7'-1 1/1" IR ADDER - CASEWU m ON 6N80 SHW -----.UN_DER - - - �E - -- -- ----- - 34x36 13'-2" BUNKROOM BATH O 005 003 I I W1 0 22 ----------T- - ---22'-33/4"-------------- - - - - / „i -.-, 52 1 8 j 1 TV - WALL MOUNT ON SWIVEL PLATFORM WOOD FLR 0 003 1� I I I I F----- I J I I I I I , I CLIlDET c tTILE BACKSPLASH BB 006 r - OPEN WD. SHELVES ABOVE --J I COUNTER AND FRIG BELOW I I I UP WOOD FLR C.H. 8' 10 7/8" STAIR 0 44 r-- FAMILY ROOM 005 CASEWORK NEW FOUNDATIO ABOVESHELF - t I2'_6"- - - WALL AND a FOOTINGSi TV (WALL OPEN - j SHELF > 6 o FINISH FLOOR j W6 v EL. 90'-3 3/4" j I I I , I , CASEWORK i 8" I 2'-3 /8" 2'-3 1/8" 8„ ABOVESHELF --- - � I I I I CONCRETE STEM WALL BELOW 18-21/2 -f - - - -�- - -- -- -- -- -- -- - - -- - -- -- - 1I fOOKS F�RI BIKES IN-- ----- CEILING N - -- - -------------------- L------------ --"IF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Bc SHELF 27.25" A.F.F. I I j 5'-8„ � I I I j I I I I I I I I I I I I I I I I I I L - - - - - — BA IT- A401 I � W5 EGRESS II UNDERPIN STONE WALL AT WINDOW OPENING 4 3 I J li A401 � � I __HVAC 4MO PORCH JND LANDING I II II III II 1'-5 5/8" j I_ 2 A401 I II II __HVAC 1 � I D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.29. 19 D.D. 10.23.19 HPC: 1.15.20 PROGRESS: PERMIT SUBMITTAL: 11.21.19 CONSTRUCTION: CHANGE ORDER BASEMENT PLAN 1/499 = -099 _ _ _ _ _ BASEMENT LEVEL ------------------- 16-65/8°........................ -----------------1-21/8„ 0' 4' 1 PROJECT # 1904 FILENAME: 1904 A.I B,1 c A200 I 4 1 A401 MAIN LEVEL_ PLAN 1 A A40 B A NEW STEEL HANDRAIL -*--------14-8 5/8"------- -14� 0 ----------- - - -- I ------------------------------------------- FRONT PORCH F 4 H.B. IEl, ��' p E I , -�-- z ,' HOOKS AND ' SHELVES. SHOE C.H.= 9'-10" CUBBIES BELOW JENTRY mw �I LIVING ROOM o WOOD ACCENT W3 101 1 WOOD FLR o WALL W/ o -6" BUILT-IN SHELF w o I m cn k-- - 1 � z a CLOSET -- - - - - -- --- - - 1 I I I I I I I ^ I I I I I I I I I m F3 w 1 TV m U cn -- 4'-9 1/8" ---- ldOVERHANG 1 LLJ ABOVE ------------------- ---- - 102 BEDROOM OFFICE TV WALLJ MAIN LEVEL FIN. FLOOR 02 --fi- EL. 100'-0" � I FLR/CLG =----'`- 1 F.P. W/ 13'-81/4- 1 DECORATIVE---------------------------------1-- - CLADDING GF A401 5'-0" _ WOOD FLR I SLEEPER SOFA ON 60X80 -------- - --------- SEE-THROUGH GAS FIREPLACE DEMO MASONRY _ 103 I GG C.H.= 9'-10° CHASE DIN STEEL COLUMN STAIR 104 I I I r I I I I I DINING I I 1 OPEN TO ABOVE M 1 UP o 103 I I 35.5'X 78.75" I I I I I 1 I W2 WOOD FLR ;OWDER GH C.H.= 8'-0" 105 106 SHW 3'-111/2 ROOM -�--------j 4----------- - I I 111 1 CAB N 1- ILI j1- VS-l BENCH - ---- WOOD FLR 1 OO o ml i t 8'-7 1/2" I 1 Ql = --------*i`---------------L- I I I I OOof =I 1 > WOOD FLR F4— o - I MW BEDROOM N BELOW 106 I I m� NI I 1 00 -'k- 2'-0" 11'-9 1/8" i --�- C.H.= 8'-0" 1—,k-------------- 52'TV -'Ir- - - —'c-- - 3'-9 5/8" KITCHEN 105 I I I 1 I ON 60X80 F3 o APPLIANCE 1 WALL ---------12 -4 1/Z-------I- - ---- OPEN -I DW 1 DISPOSAL SHELVES j ---- yELOW I -2'-8 . I I - - I ABOVE --------07 1'-10 3/8 1 2'-0" 1 3'-0" 1 2'-0" -- -- --L4-------------- �- 3'-9 3/4 I I I I BATHROOM WQOD 107 W4 b 0 SKYLIGHT 109 _0 TIE LOWER MAIN FIN. FLOOR S. ENTRY 3'-6" STEAM SHOWER --------- EL. 97'-6" 110 1 HOOKS C. _ '-g„ 1 10 CLOSET GAS � -�, � F2 ---- BENCH S-0 3/4" ------ 1'-10" SINK --- C.H. 6'-9 � I GD MUDR OM-,--2' 9 -- o w I 10 N � 1} TILE FLR 111 O CONC o LAUNDRY 108 O O w i I= NEW WINDOW GC o GE WS 1 1 I I I I I I I I 3 -8 0 NEW STEEL 4'-101/2"-* 1 1 5'-0" ELECT COLUMN-------------1141------------ I I I I 1 1 10" I I I 1 I 1 T I 1 I FORMER PORCH A401 104 11 I I I PAD FOR (2) CONDENSER UNITS I 1 I 1 I 1 I 1 I 1 I 1 DEMO PORCH AND LANDING I I ----------- I I I I I _ I I I �I 2 HISTORIC R PLACEMENT WINDOW 1 - REVISED LOCATION A401 I I I GA 1 I I I I CONC I I 4 H.B. I NEW AND RELOCATED WINDOW? I I I I GB 1 GARBAGE 7 CONTAINERS 1 I I I I I I I I 1 I COUNTER AND CABS ABOVE I I I I I � I 1 I 1 � I I I I I I I I I GATE NEW AND RELOCATEDI WINDOW. I I - 1 -------------------- - 5 81'-2 1/8' -----------------*-- I I 1 2 :A, , A40 A40 D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.28.19 D.D. 10.23.19 H PC: PROGRESS: PERMIT SUBMITTAL: 11.21.19 CONSTRUCTION: CHANGE ORDER GROUND FLOOR PLAN PROJECT # 1904 FILENAME: 1904 A201 PARTIAL SECTION AT BATH 1 /499 ^ 9 — 0" 1 Y40 iiil;4 A 440 B C -�`-----------------14-8 5/8'-------------------- 14� 0 - -- I v ---------�------------------ I 1 I 1 1 I I 1 I I I I W3 I 1 I 1 I 1 I 1 I I I I I I I 1 I 1 I 1 o I 7 I � I I I I 1 I 1 I 1 I 1 I 1 1 A401 I I I I I I I 1 I 1 I 1 � M- - - - - - - - - - - - - - ------ � I I I ` I � I I M I I � I I � I I I I I I I 4------------------ I I I I I I I I I A401 1 I I I I I I I I I I I I I I I 1 ------------------- 1 � I 1 I I I I I 1 I 1 I I I I I 1 I 1 I I I I I 1 I 1 I I 1 M I 2 A401 1 I I 1 I 1 I I I 1 I 1 I I I I I 1 I 1 I I I I I 1 I 1 --------------�- 1 -- I- - - - --- - - ------------------ --------------------------'k- I I I I I I I I I I I � I I ^ I -8" CLG HGHT 1 I I � I I [6'-0 CLG HGHT I I I I 5'-4" CLG HGHT ---------- El I I I I I I I W2 I I W3 I I I I I I BATH jI STOR 201� 2 22 0 I � i STEAM 20"x3O" 9 1 031 MIN.ACCESS SHWR 33X42 �i IBC 1209.2. A401 04 = I I BENCH TUB 60" U �I ---------'4.- I 1 I 1 I 1 I 1 I I STAIR 208 � I I \ CONT. GUARD +HANDRAIL 3 -Z( OPEN RISER j OPEN TO BELOW WOOD TREAD j A401 STAIR. I 1 - --------_--- ----- .- -- N �11 I CCESS� I i I I I I 1 I I I I I I I I I I II I I I 1 STOR 207 I EAVE STORAGE NOTE: REFRAME j 1 FLOORS LOWER = 2 W2 UNDER BOTH SHED = A 401 ROOFS AT UPPER LEVEL. � I I I 1 I 1 J I 1 I I I I I 1 I 1 I 1 I 1 I 1 I I I I I I I I I I I I 13'-10" -------------------------------------� k- I I I I 6 5/8" I I I I NEW SKYLIGHT I I GQ 1 I I I I � I I I I I I I I I I I I I I I I I 8'-7" 1 *---------------------- - ACCENT WALL+CEILING PAINTED WOODWORK j I I 72"TV I I I BEDROOM 200 1 I I 1 I I 1 I I I C.H. 7'-11-1/2" 1 I I -'k - 1 I I KING 76x80 I to I D WOOD FLOOR I I I I I I 1 I I -'k- I I 1 W2 i 1 11 I 01 1 I I 1 02 1 3'-2 3/8" 1 I `I W.I.C. HALL j ` 203 204 j I = D z I TUB m 1 60" 1 io 1 � I 10 1 BATH El-L I� 1 205 I I SHWR --7 43x33i y > � Ll I os I I R.D. I 06 07 11 09 ACCENT WALL+CEILING PAINTED WOODWORK WOOD FLOOR I I I BEDROOM j 2 66 I 1 72" TV I I I I I I I I I I I I I I KING 76z80 I I I I 10 I I I I I I I I I W3 I I I I V 2 A40 A 10 B. C UPPER LEVEL PLAN 1 /4" 1 9 — 0" 0' 4' 12' D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.29.19 D.D 10.23.19 H PC: PROGRESS: PERMIT SUBMITTAL: 11.21.19 CONSTRUCTION: CHANGE ORDER UPPER FLOOR PLAN PROJECT # 1904 FILENAME: 1904 A202 3 A401 2 A401 i A 10 B,1 ol1 D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 � 1 A401 3 A401 2 A401 ail B UPPER LEVEL PLAN 0' 4' 12' CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.29.19 D.D. 10.23.19 HPC: 1.15.20 PROGRESS: PERMIT SUBMITTAL: 11.21.19 CONSTRUCTION: CHANGE ORDER ROOF PLAN PROJECT # 1904 FILENAME: 1904 A203 5 4 3 2 1 ------------15' 44"----------------------- - - - - IC 999--------------t'-----18' 6"----------------,� UPPI MAIN I i i i i I i I I F r r I I I I I I I I I I I I I 7--------------- L-L, ,` BASEMENT LEVEL FIN FLR L--J L -i �- EL. 90 3 3/4 1 EAST ELEVATION PROPOSED A30 1 /4" - 1'-0" AMAIN EL, l i i i i i i I I I I I I I I I I I I I I I I I I I I I r LJ -1 BASEMENT LEVEL SLAB IL - ------------------------------------------------------------ I I I I I EAST ELEVATION EXISTING I_ A30 1 /4" - 1'-0" % I I M I T R I U S RESIDENCE D 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 D.D. 10.23.19 HPC: 1.15.20 PROGRESS: 11.2.19 PERMIT SUBMITTAL: CONSTRUCTION: CHANGE ORDER ELEVATIONS PROJECT # 1904 FILENAME: 1904 A301 UPPER LEVEL FLOOR EL, 110'-8" MAIN LEVEL FLOOR EL. 100'-0" BASEMENT LEVEL FIN FLR EL. 90'-3 3/4" UPPER LEVEL FLOOR EL, 110 8 MAIN LEVEL FLOOR EL. 100 0 BASEMENT LEVEL SLAB EL, 93'-4 1 2 A B B,1 C 9 1 9 9y ,1 - 2,g, .�-----------14'85"------------------12'10�---------, +-�' i I�LVV VVII�UUVV COLUMN I r r r - I I I I I I I I I I I I I L--J I I L J SOUTH ELEVATION - PROPOSED 1 /4" ^ 9 - 0" 1 402 12 12 I i I I I I I I I I I I I I I I - I I I L---J SOUTH ELEVATION EXISTING I I I I I I I I I I I I I I I I I I I I I I IJ--J PROPERTY LINE / C B A .'----------- 14'-O8"----------- 14'-8g'y___________,• 2 1 402 A40 12 12 111/ al ;ISTING SHINGLES UPPER LEVEL FLO EL. 110'-8" MAIN LEVEL FLOOR EL. 100'-0' UHMU NUN -HIS I UHIU HANDRAIL/GUARDRAIL. I I I I I I I I I I I I I I I I I I L__J I I L---jiI L JI BASEMENT LEVEL FIN ELR EL. 90'-3 3/4" 3 NORTH ELEVATION - PROPOSED 30 1 /4" - 1 >-0„ 1 A40 m I I i I I I I I I I I I I I I I I I I I I I I I I I I I -- r � I I I I I I I I I NORTH ELEVATION - EXISTING D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCNITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 )RMER WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT UPPER LEVEL FL00�L EL. 110 8 MAIN LEVEL FLOOR EL. 100 0 BASEMENT LEVEL SLA EL. 93 —4 1 2 DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 D.D. 10.23.19 HPC: 1.15.20 PROGRESS: 11.2.19 PERMIT SUBMITTAL: CONSTRUCTION: CHANGE ORDER EXISTING +PROPOSED ELEVATIONS PROJECT # 1904 FILENAME: 1904 1 /4" ^ 9 - 0" 1 /4" ^ 9-099 A302 CLAPBOARD &DIN PROPERTY LINE OLD GATE, FENCE 0/ RETAINING WALL. EW WOOD FENCE Qo ; I i i I N [I]I:1RCi17:1all 1L`1117111 PROPERTY LINE OLD GATE, FENCE 0/ RETAINING WALL. I I p Q 9 791 �� 9 1 19 • , 6 _11— — 1g) 91 —6-—————————— — — — — —, 169 99 _--------------+------------15 —4 _ __________ t i1 2 A401 SHINGLES A401 I I -5 1 /T� ---5=51/2---- -- - - - - - - - - - - - - - - - - t -t - - - - - - - - BB I SLIDER I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I J 1 WEST ELEVATION PROPOSED 30 1 /4" — V-099 1 (A4401 SHINGLES 01 I I I NON —HISTORIC CASEMENT I i I I ILjI I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I r r - I I I I I I I I I I I I I I I I I I L WEST ELEVATION — EXISTING L__J D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 UPPER LEVEL FLOOR EL, 110 8' NEW WINDOW I PROPERTY LINE CONSULTANTS i i NEW FENCE Q ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO % I z % MAIN LEVEL � CONTACT: WILLIS PEMBER EL. 100'-0" (V) 970 9201727 GD �o MAIN LVL REAR FLR oL STRUCTURAL ENGINEER EL. 97.5'—Ong EVOLVE ENGINEERING ` 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS L (970) 618 7708 SURVEYOR SOPRIS ENGINEERING BASEMENT LEVEL FIN FLR h EL. 90'-3 3/4" 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA XHAUST PIPE UPPER LEVEL FLOOR EL. 110'-8" MAIN LEVEL FLOOR EL. 100'-0" MAIN LVL REAR ELR h EL. 97.5'-0"� BASEMENT LEVEL EL. 93'4 1 /2" CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY RUDD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 D.D. 10.23.19 HPC: 1.15.20 PROGRESS: 11.2.19 PERMIT SUBMITTAL: CONSTRUCTION: CHANGE ORDER ELEVATIONS PROJECT # 1904 FILENAME: 1904 1 /499 — V-099 A303 GR� GRADE I I A B C 14'-8 5/8" 14'-0 3/8" A40 1 /4" 1 ' 0" (EGRESS WINDOW ONLY) 12 � 3 � E=A�) 1 VVE=) 1 �)E U I IUIN I HHUUUH �) I Al PER LEVEL FIN. FLR 110'-8" PER LEVEL BATH 108'-8 5/8" I I I I I o I I I i I IN LEVEL FIN, FLOOR 100'-0" i I i � I I I ORMER ASEMENT LEVEL SLAB 93"-4 1 /2" j �i 0 \SEMENT LEVEL FIN FLOOR 90'-3-3/4"' Moaea■iLiamaln■a■ I PPER LEVEL BATH 108'-8 5/8" I i I I I I I o I AIN LEVEL FIN. FLOOR 100'-0" I I I i i i -ORMER BASEMENT LEVEL SLAB -L. 93"-4 1 /2" of i ASEMENT LEVEL FIN FLOOR L. 9 0 3 3 4"' (: - A B B�1 C _____.LL 1 2 14'-8 5/8" 14'-0 3/8" __ .._._._....._._._._._._._ _ - - - - - - - - — 7-7 . EAST WEST SECTION 1 /499 ^ 9 0" PER LEVEL FIN. FLR. 110'-8" i PER LEVEL BATH FIN.! FLR. 108'-8 5/8" I i I I I I I I I � I I b I I I I I I I IN LEVEL FIN. FLR, STAIR )RIVER ASEMENT LEVEL SLAB 93"-4 1 /2" \SEMENT LEVEL FIN. FLR 90'-3 3/4"' D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER j� EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 � I SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 I LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.29.19 D.D. 10.23.19 HPC: 1.15.20 PROGRESS: PERMIT SUBMITTAL: 11.21.19 CONSTRUCTION: CHANGE ORDER EAST -WEST SEICTIONS full BASEMENT PROJECT # 1904 FILENAME: 1904 A40 1 1 /4" ^ 9-0" 5'-5 1/2' 1 -- - -- - -- I i of vl i i i 5'-8" 1 - ---------- I- E3C � I �i BASEMENT GENERAL NOTES: DOOR SCHEDULE 1. REFER TO ENERGY CALCS TO VERIFY 'U' AND 'SHGC' NUMBERS 2. CONTRACTOR TO VERIFY IN FIELD ALL MEASUREMENTS PRIOR TO ORDERING, 3. ALL EXTERIOR DOORS UNLESS OTHERWISE NOTED TO BE 'LOEWEN' BRAND IN BLACK CLAD WITH U-VALUE OF .28 4. TEMPERED GLASS WHERE REQUIRED BY CODE. 5. SWING DOOR 'U' VALUE IS .28. 6. ALL GLASS STOP TO BE SQUARE EDGED - ALL UNITS. 7. TEMPERED GLASS WHERE REQUIRED BY CODE. 1/2' -------- T ti GENERAL NOTES: WINDOW SCHEDULE 1. REFER TO ENERGY CALCS TO VERIFY 'U' AND 'SHGC' NUMBERS 2. CONTRACTOR TO VERIFY IN FIELD ALL MEASUREMENTS PRIOR TO ORDERING. 3. ALL NEW WINDOWS UNLESS OTHERWISE NOTED TO BE 'LOEWEN' BRAND, BLACK CLAD EXT, WITH THE FOLLOWING U-VALUES: U-VALUE DOUBLE GLAZED Low-E, 189 FIXED WINDOWS = .28 SLIDER WINDOWS .28 DOUBLE HUNG WINDOWS .28 4. SKYLIGHT; SB IS TO BE VELUX' WITH BLACK FRAME TO COMPLY WITH HPC APPROVAL. U VALUE=.55 OR BETTER. 5. TEMPERED GLASS WHERE REQUIRED BY CODE 6. ALL GLASS STOP TO BE SQUARE EDGED - ALL UNITS. GENERAL NOTES: HISTORIC WINDOWS AND DOORS 1. REPAIR FRAMES AND SASHES RATHER THAN REPLACE 2. PRESERVE ORIGINAL GLASS, WHEN FEASIBLE 3. REPLACE GLAZING COMPOUND, REPAIR WOOD MEMBERS, INSTALL WEATHER-STRIPPING 4. AVOID REPLACEMENT OF HISTORIC WINDOWS. 1. Prescriptive Alternative: Use the values out of Table R402.1.2 for insulation and fenestration (printed below). Your details, sections, and/or schedules must be noted with these R and U values. 2015 IECC Table R402.1.2 (as amended by City of Asgen Ordinance 40.2016) WOOD CRAWL FRAME MASS BASEMENT SLAB SPACE CLIMATE FENESTRATION SKYLIGHT CEILING WALL WALL FLOOR WALL R-VALUE WALL ZONE U-FACTOR U-FACTOR R-VALUE R-VALUE R-VALUE R-VALUE R-VALUE & DEPTH R-VALUE 7 0.28 0.55 49 20 +5 or 19/21' 389 15/191 10,4 ftd 15/19` 1 1 13+10' 1 1 1 I Table Footnotes: c. "15/19" means R-15 continuous insulated sheathing on the interior or exterior of the home or R-19 cavity insulation at the interior of the basement wall. "15/19" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulated sheathing on the interior or exterior of the home. "10/13" means R-10 continuous insulated sheathing on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. d. R-5 shall be added to the required slab edge R-values for heated slabs. Insulation depth shall be the depth of the footing or 2 feet, whichever is less in Zones 1 through 3 for heated slabs. g. Or insulation sufficient to fill the framing cavity, R-19 minimum. h. The first value is cavity insulation, the second value is continuous insulation, so "13+5" means R-13 cavity insulation plus R-5 continuous insulation. I. The second R-value applies when more than half the insulation is on the interior of the mass wall. 2'-10 7/8" � 102 FIXED DOOR SCHEDULE DR. # ROOM # - TYPE SIZE (NOMINAL) DETAILS REMARKS W x H THK. HEAD SILL JAMB 001 002 SWING 3'-0" X 7'-0" 1 3/4' 11 /A602 - l l /A602 ALL OPTIONS 002 002 SWING 3'-2" X 6'-2" 1 3/4' - HALF BASEMENT OPTION ONLY 003 003 SWING 3'-0" X 7'-0" 1 3/4' 11 /A602 - l l /A602 FULL BASEMENT OPTION ONLY 004 001 SWING 2'-2" X 7'-0" 1 /2" 11 /A602 l l /A602 FULL BASEMENT OPTION ONLY GLASS SHOWER 005 002 POCKET 3'-0" X 7'-0" 1 3/4' 11 /A602 l l /A602 FULL BASEMENT OPTION ONLY 006 003 SWING 2'-10" X 7'-0" 1 3/4' 101 100 SWING 3'-0"" X 7'-8" 1 3/4'- - - HISTORIC FRONT DOOR 102 101 SWING 2'-8" X 7'-0" 1 3/4' 11 /A602 l l /A602 METAL GLASS FRENCH DOOR SYSTEM AND SIDELIGHT 103 104 POCKET 2'-8" X 7'-0" 1 /2" 11 /A602 l l /A602 METAL GLASS POCKET DOOR SIM TO 102 104 104 FIXED 2'-10" X 7'-0" 1 3/4' 11 /A602 - l l /A602 EXTERIOR GLASS DOOR REPLACEMENT, FIXED 105 111 SWING 2'-10" X 7'-0" 1 3/4' 11 /A602 - l l /A602 - 106 111 SWING 2'-3" X 7'-0" 1 /2" 11 /A602 - l l /A602 FRAMELESS GLASS SHOWER 107 106 SWING 2'-8" X 7'-0" 1 3/4' 11 /A602 - l l /A602 - 108 107 SWING 2'-10" X 7'-0" 1 3/4' 11 /A602 l l /A602 - 109 107 SWING 2'-4" X 7'-0" 1 /2" 11 /A602 l l /A602 FRAMELESS GLASS SHOWER 110 110 SWING 2'-10" X 7'-0" 1 3/4' 11 /A602 l l /A602 HISTORIC BACK DOOR ill 108 POCKET 2'-10" X 7'-0" 1 3/4' 11 /A602 l l /A602 201 200 SWING 2'-6" X 7'-0" 1 3/4' - - - - 202 200 SWING 2'-8" X 7'-0" 1 3/4' - 203 201 SWING 2'-3" X 7'-0" 1 /2" 3/A607 3/A607 - FRAMELESS GLASS SHOWER 204 202 ACCESS PANEL 2'-4" X 4'-0" 1 1 /2" - 3/A603 - ACCESS PANEL REMOVEABLE 205 205 SWING 2'-4" X 7'-0" 1 /2" - 3/A603 - FRAMELESS GLASS SHOWER 206 205 POCKET 2'-0" X 2'-6" 1 3/4' 11 /A602 - l l /A602 PASS THRU WINDOW / DOOR (1-HOUR RATED) 207 206 SWING 2'-8" X 7'-0" 1 3/4' - - - - 208 207 ACCESS PANEL 2'-4" X 4'-0" 1 1 /2" ACCESS PANEL REMOVEABLE 209 206 FRENCH SWING 2'-6" X 7'-0" 1 3/4' 11 /A602 - l l /A602 - 210 206 FRENCH SWING 3'-0" X 6'-6" 1 3/4' 11 /A602 - l l /A602 - I 0I M i -11 GROUND FLOOR 2'=1 3 / 8' T- i I GC � i (U I 4'-5" a I N VELUX MI UPPER LEVEL 911 D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 GH GG PASADENA, CA 91101 WINDOW SCHEDULE - NEW WDW. # FRAME SIZE DETAILS OPERATION REMARKS WxH HEAD SILL JAMB JAMB BA 5'6" x 5'3" VIF 8/A602 4/A602 8/A602 SLIDER EGRESS NOTE #A BB 5' 5" x V 9" VIF 8/A602 8/A602 8/A602 SLIDER NOTE #A BC 5' 8" x V 9" VIF 8/A607 8/A603 8/A602 SLIDER NOTE #A GA 2'3" x 5'4" VIF 8/A607 8/A603 8/A602 DOUBLE HUNG NOTE #A SITE MULLED UNITS GB 1'7 1 /2" x 3'8" VIF 8/A607 8/A603 8/A603 DOUBLE HUNG NOTE #A GC 2' l" x 7' 2" VIF 8/A607 8/A603 8/A603 DOUBLE HUNG NOTE #A GD 2'1" x 7'2" VIF 8/A604 8/A604 8/A604 DOUBLE HUNG NOTE #A GE 2'7" x 583/8" VIF DOUBLE HUNG NOTE #A GF 2'7" x 583/8" VIF DOUBLE HUNG NOTE #A GH V 8" x 4' 0" VIF FIXED FROSTED THERMAL PANEL ON INSIDE OF HISTORIC ETCHED GLASS GG V 8" x 4' 0" VIF FIXED FROSTED THERMAL PANEL ON INSIDE OF HISTORIC ETCHED GLASS UA 2'0" x 3'3" VIF EXISTING EXISTING EXISTING EXISTING DOUBLE HUNG NOTE #A UB 3'2" x 4'5" VIF 8/A607 8/A607 2/A607 FIXED VELUX SKYLIGHT - NOTE #D REMARKS NOTES: #A ALL NEW WINDOWS LOEWEN WITH U OF .28 OR BETTER. #B DETAILS PROVIDED BY MANUFACTURER #C ALL EXISTING WINDOWS MUST BE RE -USED, REFURBISHED AND OPERABLE (IF ORIGINALLY OPERABLE) #D SKYLIGHT U FACTOR .55 OR BETTER. #E C O N S U L T A N T S ARif_HITGPT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER n/a MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ROARING FORK VALLEY 970 945 2326 ANDY SILVERMAN 970 384 4627 GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.28.19 D.D. 10.23.19 H PC: PROGRESS: 11.08.19 PERMIT SUBMITTAL: CONSTRUCTION: CHANGE ORDER WINDOW . DOOR SCHEDULE PROJECT # 1904 FILENAME: 1904 A801 N❑TES: 1, XXXXXXX 1. CARBON MONOXIDE AND SMOKE DETECTORS AS RE'QD BY CODE. 2. LOCATE AND VERIFY SELECTED USB—C OUTLETS WITH OWNER PRIOR TO INSTALLATION. J. COORDINATE WORK WITH OWNER'S AV CONTRACTOR ELECTRICAL_ SYMBOL KEY EXHAUST TAN —0 WALL MOUNTED LIGHT FIXTURE STANDARD SWITCH SWITCHED OUTLET (3 DATA PERT OUTLET THERMOSTAT (4) PENDANT LIGHT FIXTURE DIMMER SWITCH FL❑❑R OUTLET INCLUDES DATA/INTERNET AUDI❑ —0 GAS C❑NNECTI❑N CEILING MTD LIGHT FIXTURE —64 3 WAY SWITCH ® SPECIAL PURPOSE OUTLET CATV V❑ICE/PH❑NE � STANDARD DUPLEX OUTLET "STEP' LIGHT FIXTURE PHOTO CELL SWITCH WATERPR❑❑F ❑UTLETwP ;CD) CARBON M❑N❑HIDE DET, STANDARD F❑UUPLEX ❑UTLET TRACK FIXTURE TIMER SWITCH f PH❑NE OR DATA JACK \ G F,I, ❑UTLET 0 FLUOR,INT, LIGHT FIXTURE WATER PROOF SWITCH CATV JACK IN—GR❑UND LIGHT \ SM❑KE ALARM JAMB SWITCH RECESSED 6" LINE VOLTAGE o LANDSCAPE PATH LIGHT RECESSED CURTAIN TRACK RECESSED CEILING SPEAKER ;, RECESSED SURFACE SPEAKER V❑LUME SWITCH 0 RECESSED 4" L❑W VOLTAGE (,Q SPEAKER dweLED Farmhouse Outdoor Wall Sconce 3000K Model&Size Color Temp&CRI Finish Won LED Lumens WS-W68913 13" 3000K 90 0GH Graphite I12W 1900 w5-wea913 3000a 90 Example: WS.W68913-BK DESCRIPTION A romantic, rain -against Illuminated. FEATURES -the -window appearance that sparkles when • Driver concealed within the Fixture 5 year warranty SPECIFICATIONS Color Temp: 3000K Input: 12o-277 VAC, 50/60Hz CRI: 90 Dimming: ELV:100-10%, 0-10V: 100 - 10%, TRIAC: 100 - 109h Rated Life: 64000 Hours Standards: ETL, cETL,IP65 Wet Location Listed Construction: Aluminum body with seeded hammered glass REPLACEMENT PARTS RPL-GLA-68913 - Glass for WS-W68913 Fixture Type: WALL SCONCE Catalog Number: WS-W689I3-Ex Project: 125 WEST MAIN Location: ASPEN, CO Delivered Lumens Title 24 205 No 20 No FINISHES No1111 LINE DRAWING �73/8n 13"1 — 6"--� F-35/8!- WS-W68913 waclighting.com I Phone (800) 526.2588 I Fax (800) 526.2585 1 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NV 11050 'NAG llghUng remins the right to modify the design ofourproductso[ any dme aspart ofthe romporry'swndnuouslmpmvementprogmm. 11111ry2020 1 FRONT DOOR WALL LI CH T FIXTURE 'H' X x X X x PNIuPS LIOHTQLIE R 1:0 0 cal.. TY s pe 4b: 3` Accent s quote adjustable 800 Lumens Philips LiahtoLie r LyteCaster LED Ac cerR adjustab be featu res a 3S' U"noire height that co rserti sp Lenum sp ace without co mpro musing the 35' adjl stab le tilt . T he modu Lar and i note rchangeab le Ii ght erl re albws to r an easy tuna m upgrade. T he a ent adpa tab In is d amp locatio n Ii �d and comes in 2standard finish options. Complete product = Frarne-in kit +Light engine +Trim Order each sap arat0y Ordennggusde: Frama-in ll E."pl. Al 5Qaa5 Fr.^'p t5yn a��-�+ng npy[•+o [ge L3 L3 Lyt@Ca3tg3 A AirSeal lC, Flew Care trot tbn,5crpw E ELWTixdmmng 1 12M Acog,[ AH nirseaLlc,Ne c,crsstnx t on, t4aiL N hl_ {_lr_bonF nl{ Z10 0-10V u L irr aLnh 70 Orderingguide: LVhtengine EranlMaL#�1]rf `AXi3 Ltr�in$ Q1 CCT BiSm CptlOn L3 ® E ❑ ❑ L�te­ el� os s so _ sp Ac—t 303ooaK �.1e° NF Nx wAope ,20� 75 3`J';Dh F F144tl,27° 9 2Q 27 2ia1i S 5"-1 CWSri�p'white' 303o , NFNxrawFboe,— F Flapc,xr° Orderingguide:Squaretriim E­plL35r•D I... sx Lw.i mlm tvw P^ Rs^ 73 71 [T] 71 L3 L}rQcosbgrE 5 HcuYe A ouAxie ❑ olRusemrp bmik wriib� Acoq,t A Aluni— t a000usneo Wwmeomuz eo«e«aee�ouo Oil LyMCaSw L35_iWuRYloFr app5 ,vts wau,ds Iwo RECESSED PORCH LIGHTS FIXTURE 'AAA' 10-5/ /8" WIDE E PATH AND WALE EIGHT FIXTURE 9K'+'KK' 3 5 " ELECTRICAL SCHEDULE DATE: 11.15 2019 PROJECT # 1904 — 125 W MAIN ST MARK TYPE MANUFACTURER 4 LAMP FINISH/TRIM BEAM SPREAD REMARKS A SURFACE LINEAR LED D❑WN—LIGHT PINNACLE EX33 W/LENS 3000K WHITE NA INDIVIDUAL 2' FIXT'S I M❑UNT T❑ BOX DIMMEABLE AA IBIS HEAD LED — CLG M❑N❑P❑INT TECH LIGHTING MP—IBIS—WW LED/3000K WHITE W W USE W/FLUSH 4'SQ, FREEJACK LED (WHITE) DIMMEABLE AAA 3"x3" RECESSED DOWN LIGHT LIGHT❑LIFR L3 ACCENT SQ 300/3500K WH 'W' FLOOD IC H❑USING NOT NEEDED B WALL MOUNT — SWITCH AT FIXT, ARTEMIDE JET/WALL LED 1W 3000K ALUMINUM — DEC❑RATIVE READING LIGHT C 2'x4' SURFACE MOUNTED FLUOR, TBD -- CFL — — D BATH FANS PANAS❑NIC FV-0511VK2 WHISPER GREEN SELECT WHITE 80CFM FULL BATHS, 50CFM POWDER E DEC❑RATIVE PENDANT TBD --- LED BLACK ALL❑WANCE $600/EA F VANITY MIRK❑R LIGHTS CASABATH -- -- — — PR❑VIDE POWER TO EACH BATH MIRR❑R G LINEAR ROPE LIGHTS HM LIGHTING ❑R EQUAL LTR 300 LED RIBB❑N S❑-WW3500K 12V DC DIMMEABLE H EXTERI❑R WALL SCONCE ALL❑WANCE $400/EA J DEC❑RATIVE PENDANT— DINING R❑❑M TBD MULTI STEMMED ALL❑WANCE $10,000 K+KK EXTERI❑R PATH LIGHTS ARTEMIDE CICL❑PE FLOOR 6W LED DIRK GRAY X INDICATES HIGH EFFICACY LAMPING T❑ MEET CODE ++ INDICATES DEC❑RATIVE LIGHTING FIXTURE — REF ALLOWANCE #1 WHOLE HOUSE SOUND, DATA, CATV, TV AND SECURITY BY ❑WNER'S CONSULTANT N❑TE: ALL EXTERI❑R FIXTURES TO REMAIN AS THEY ARE — NO CHANGE MAIN LEVEE ELECTRICAL PLAN D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL ANDY SILVERMAN GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 8.28.19 D.D. 10.23.19 H PC: PROGRESS: PERMIT SUBMITTAL: CONSTRUCTION: CHANGE ORDER LOWER FLOOR ELE(PLAN PROJECT # 1904 FILENAME: 1904 E201 1 /499 1 9 — 099 1 1 A401 Zl(�2 ;401 BASEMENT PLAN -- -- --- - -1 S-10499- - - i i i i i D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST ° 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 1--loo o� i i CONSULTANTS ° i i i i ARCHITECT or WILLIS PEMBER ARCHITECTS, INC 1 412 N. MILL ST. A 401 ASPEN, CO CONTACT: WILLIS PEMBER —i00 � (V) 970 920 1727 � STRUCTURAL ENGINEER °o EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 I SURVEYOR i SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT i NA 00 CIVIL ENGINEER - I WOODY CREEK ENGINEERING, LLC 5599 8 P.O. BOX 575 WOODY CREEK, CO 81656 2 CONTACT: JOSH RICE A401 970 309 7130 SOILS ENGINEER i TBD MECHANICAL CONSULTANT DESIGN -BUILD BY RUDD 0' 4' i i S.O.G ABOVE ----------------- 9 J 12' GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 H PC: PROGRESS: PERMIT SUBMITTAL: 11.21.19 CONSTRUCTION: CHANGE ORDER BASEMENT LEVEL PROJECT # 1904 FILENAME: 1904 1 /499 1 9-o99 EX200 1 40 711, %% , 1„ 399 g4 ;'----------- 13' 6"----- ------L -4' 11"4-1I- l _ __g _439f4__-_- �.�. i ° ° i -- °j - - - - - - - - - - -i ID I M I T R I U S FRONT DORCH ,' � RESIDENCE ---------------------------------- -------- 1 2 5 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 ______________ O %% _ _ _ _____ ' -_T_- _- OWNERS ° 00 00 ENTRY - - - ---------- -------- - - - - >� RALLI DIMITRIUS TRUST ----------------- 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 7 5919,E-,_1199-__,..----8' 62"---- - 3,� 4 2 I - -- -- -- -- -- -- -- -- -- -- -- LIVING ROOM i .'.' 73" CABINET C O N S U L T A N T S I i '------------------- 13i ' C.H.= 9'-10" 1 A401 _IN BEDROOM A401 ARCHITECT WILLIS PEMBER ARCHITECTS, INC WOOD -BURNING 412 N. MILL ST. � N FIREPLACE CO ®ASPEN, ,'---------13'-3----------,' 4 CONTACT: WILLIS PEMBER .� (V) 970 920 1727 C.H.= 9'-10" .. ` 68 `�' STRUCTURAL ENGINEER CDEVOLVE ENGINEERING ----------------._ -- -- ;{: r`co 1040 MAIN STREET _ _._--- ---- -------- -- -f: CARB0N0ALE,l;001b'23 "rise CONTACT: SARA MICKUS 84" DINING N (970) 618 7708 - _____ ____LF__________ mil` ` SIN Lc) SURVEYOR -3�8 " i SOPRIS ENGINEERING6 PORCH 502 MAIN ST, STE A3 ❑ CARBONDALE, CO 81623 ---------- CONTACT: MARK BECKLER `--- �00 ------- - - - - -- - (V) (970) 704-0311 =1;- - - - - - - - - - -- -- - - C.H.= 9'10" ❑ C.H.= 9'-10" LANDSCAPE ARCHITECT NA I j SIN KITCHEN 0 uo CIVIL ENGINEER 2 2 WOODY CREEK ENGINEERING, LLC A401 BEDROOM 1 „ A401 P.O. BOX 575 .'--- -----12 4- - - - -- - - -.' WOODY CREEK, CO81656 0 o O O I CONTACT: JOSH RICE ® 970 309 7130 GONG -I0 SOILS ENGINEER � i TBD i -------�________________ {� _ �� ` - -------------------- - - - - ----- .L lr ----- - - - --- �� r�l� Lf MECHANICAL CONSULTANT DESIGN -BUILD BY RUDD 399 GENERAL CONTRACTOR N� 78 .'.' ------- - ...-.-...- - - - - - - - - - - - - - - - - RUDD CONSTRUCTION 132 PARK AVENUE 0--) BASALT, CO 81621 c� CONTACT: SCOTT DURYEA GAS 1 g (o (V) 970 618 7200 _ ----:-:-:-:- - _ _ _ �I _._._._._._._._._._._ LAUNDRY —i� CDCO C GAS ISSUE: �! UTILITY ; 0 S.D. 7.19.19 HPC: _________________ - - - - - - - - _ PROGRESS: PERMIT SUBMITTAL: 9.21.19 o ELEC GATE CONSTRUCTION: CHANGE ORDER I j 399 ' 10 114 - i 1 99 4 586 iii 1 99 112 - -.'2 i i i 1 99 112.1ei i 3 4499 3�9, 4199 2 19 2199 8 GROUND FLOOR PLAN A MAIN LEVEL PLAN A20 1 /4" — 1'-099 HISTORIC WALL TYPE ADDITION WALL TYPE PROJECT # 1904 1 2 , `• FILENAME: 1904 A40 A40 -100 � ' r�I� F-- Nu% % EX201 1 A401 ♦�------------- _______------ ___. Do I N 0 i � I i i I 0 d�� i ♦J______J_____________ i � ,r-----------139 9) -10 - -- -- -- -- --.T,; 65„ 8 d d 12' UPPER LEVEL PLAN 1 A401 2 A401 D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY CLIMATE CONTROL GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 H PC: PROGRESS: PERMIT SUBMITTAL: 9.21.19 CONSTRUCTION: CHANGE ORDER UPPER FLOOR PLAN PROJECT # 1904 FILENAME: 1904 EX202 65„ 8 .*- - �9— o99_ - - - - - - - - - -�t��- - - - - -79— /� 99- - - - - jI i ii ; j, UPPER LEVEL FLOOR EL. 110 -8 ` i i i 00 0 i MAIN LEVEL FLOOR %[ EL. 100 -0 i` i SIN I �o i j� BASEMENT LEVEL SLAB EL. 100 -0' ` EAST WEST SECTION SECTION 1 /499 ^ 9-099 65„ 8 ' I i EAST WEST SECTION SECTION 1 /499 1 9-099 I all D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY RUDD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 H PC: PROGRESS: PERMIT SUBMITTAL: 9.21.19 CONSTRUCTION: CHANGE ORDER AS-BUNT EAST -WEST SECTIONS PROJECT # 1904 FILENAME: 1904 EX401 uPP MAID EL. B A' uPP MAID EL. SLOW[ V EL. B A' Y EL. NORTH SOUTH SECTION 1 /499 - ^ 9-099 NORTH -SOUTH SECTION D I M I T R I U S RESIDENCE 125 WEST MAIN STREET ASPEN, CO 81611 PARCEL ID # 273707392007 OWNERS RALLI DIMITRIUS TRUST 530 SOUTH LAKE AVENUE #433 PASADENA, CA 91101 CONSULTANTS ARCHITECT WILLIS PEMBER ARCHITECTS, INC 412 N. MILL ST. ASPEN, CO CONTACT: WILLIS PEMBER (V) 970 920 1727 STRUCTURAL ENGINEER EVOLVE ENGINEERING 1040 MAIN STREET CARBONDALE, CO 81623 CONTACT: SARA MICKUS (970) 618 7708 SURVEYOR SOPRIS ENGINEERING 502 MAIN ST, STE A3 CARBONDALE, CO 81623 CONTACT: MARK BECKLER (V) (970) 704-0311 LANDSCAPE ARCHITECT NA CIVIL ENGINEER WOODY CREEK ENGINEERING, LLC P.O. BOX 575 WOODY CREEK, CO 81656 CONTACT: JOSH RICE 970 309 7130 SOILS ENGINEER TBD MECHANICAL CONSULTANT DESIGN -BUILD BY RUDD GENERAL CONTRACTOR RUDD CONSTRUCTION 132 PARK AVENUE BASALT, CO 81621 CONTACT: SCOTT DURYEA (V) 970 618 7200 ISSUE: S.D. 7.19.19 H PC: PROGRESS: PERMIT SUBMITTAL: 11.21.19 CONSTRUCTION: CHANGE ORDER NORTH SOUTH SEICTIONS-EXISTING PROJECT # 1904 FILENAME: 1904 1 /499 - ^ 9-099 EX402 STRUCTURAL GENERAL NOTES GENERAL 1.All construction shall conform to the 2015 editions of the International Residential Code (IRC) & International Building Code (IBC), and the City of Aspen amendments. 2.Details not specifically shown on these drawings shall be similar to details for like construction as shown on these drawings. 3.The Contractor shall verify all dimensions and conditions at the job site, and shall report any discrepancies to the Architect and Structural Engineer of Record (S.E.O.R.) before proceeding with work. 4.Refer to Architectural drawings for dimensions and other information not specifically shown on Structural Drawings. Dimensions shown are approximate and are provided as an aid in interpreting the drawings and must be verified with the Architectural drawings. In the event of conflict, dimensions shown on the Architectural drawings shall govern. Notify the S.E.O.R. of any discrepancies prior to constructing the impacted portions of the work. Scaled dimensions shall not be used. 5.No structural members shall be cut, notched or otherwise penetrated unless specifically approved by the S.E.O.R. in advance or as shown on these drawings. 6.Provide openings, curbs, framing, supports and attachments for items as indicated on Architectural, Mechanical, Electrical or other drawings included in the Construction Documents. 7.Where these General Notes and typical details are in conflict with the Specifications, these Notes and Details shall govern. MANUFACTURED WOOD PRODUCTS 1.Manufactured wood I-joists shall be installed in accordance with the manufacturer's recommended details for blocking, bracing, bearing and connections. See plan for size, depth and product designations. Any alternate products shall be submitted to the engineer for written approval prior to construction. 2.Laminated Veneer Lumber (LVL) beam & column plies shall be 1 3/4" in width with number of plies and depths as noted on plan. LVL shall have the following minimum working stresses: Fc pll=2,510 psi, Fb=2,600 psi, Fv=285 psi, E=2,000,000 psi. 3.Laminated Strand Lumber (LSL), beams (1 3/4" min) and rimboard (1 1/4" min) shall be as noted on plan, with the following minimum working stresses: Fc pll=1,400 psi, Fb=1,700 psi, Fv=400 psi, E=1,300,000 psi. 4.Versa-Stud (1 1/2" min) shall be noted on plan, with the following minimum working stresses: Fc pll=3,000 psi, Fb=2,400 psi, E=1,700,000 psi. 5.Parallel Strand Lumber (PSL) beams shall be as noted on plan with the following minimum working stresses: Fb=2,900 psi, Fv=290 psi, E=2,000,000 psi. 6.Parallel Strand Lumber (PSL) columns shall be as noted on plan with the following minimum working stresses: Fc pll=2,500 psi, Fb=2,400 psi, Fv=190 psi, E=1,800,000 psi. 7.Glulam (GL) beams shall be as noted on plan with the following minimum working stresses: 24F-V4, Fb(tension zone)=2,400 psi, Fv=265 psi, E=1,800,000 psi. All mult-span beams, including cantilever conditions, shall be 24F-V8 unless noted otherwise in the drawings. 8.Manufactured wood products as noted above shall be installed per manufacturer's specifications. 9.Manufactured wood products in contact with concrete or masonry foundation or exposed to exterior conditions shall be treated per manufacturer's specifications. 10.Wood manufactured products other than those noted, which have ICC-ES approval, may be used with approval by the engineer of record. Substitutions made by the Owner or Contractor shall include all connection hardware as required for sizes used, and shall have equivalent load ratings as those called for on the Drawings. STRUCTURAL ERECTION AND BRACING REQUIREMENTS 1.The Structural Drawings illustrate the completed structure with all elements in their final positions, properly supported and braced. 2.The Contractor, in the proper sequence, shall provide shoring and bracing as required during construction to achieve the final completed structure. Design, sequencing, location, placement, etc. of bracing and shoring is the responsibility of the Contractor. 3.The Contractor shall be responsible for the safety of the building and workers during construction. The Contractor shall comply with all applicable safety regulations. BACKFILLING 1.Contractor shall not backfill against basement and/or retaining walls until all supporting elements (ex: concrete slabs and/or floor framing) are in place and securely anchored, or until adequate temporary shoring is installed. 2.Contractor shall verify type of backfill material with Geotechnical Engineer prior to backfilling. FASTENER AT NEAR FACE FASTENER AT FAR FACE (3-PLY & 4-PLY ONLY) PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 10d NAILS @ 12"o.c.ONE FACE EA FACE PLY TO PLY CONNECTION 3-PLY2-PLY 2 ROWS 12d NAILS @ 12"o.c.ONE FACE EA FACE 2" 12"/24"o.c.2" PLY TO PLY CONNECTION 3-PLY2-PLY 3 ROWS 16d NAILS @ 12"o.c.ONE FACE EA FACE 4-PLY EA FACE2 ROWS 1/4"x6" SDS SCREWS @ 24"o.c. 4-PLY 3 ROWS 1/4"x6" SDS SCREWS @ 24"o.c.EA FACE FOR COLUMNS OVER 3-PLY, ATTACH EACH ADDITIONAL PLY w/ (2) ROWS OF 10d NAILS @ 12"o.c. SAWN LUMBER (2" NOM. THICKNESS) CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH < 14" CONNECTION SCHEDULE LVL 1 3/4" THICK, MEMBER WIDTH > = 14" CONNECTION SCHEDULE 2-PLY MEMBER 3-PLY MEMBER 4-PLY MEMBER ELEVATION 1. FLOOR SHEATHING SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS FLOOR SHEATHING, RATED STURD-I FLOOR, 24" o.c, 23/32" THICK, T & G OR 1 1/8" WARMBOARD-S. FLOOR SHEATHING SHALL BE GLUED AND FASTENED TO FLOOR JOISTS & BEAMS USING ADHESIVES CONFORMING TO APA SPECIFICATION AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. REMOVE WATER, DUST AND DEBRIS FROM JOISTS. APPLY GLUE TO JOISTS & BEAMS AND COMPLETE ALL FASTENING BEFORE GLUE SETS. FLOOR SHEATHING USED AT EXTERIOR DECKS SHALL BE LABELED "EXTERIOR" OR "EXPOSURE 1". 2. ROOF SHEATHING SHALL BE AS FOLLOWS: WOOD STRUCTURAL PANELS CERTIFIED BY THE APA FOR USE AS ROOF SHEATHING, LABELED "EXTERIOR" OR "EXPOSURE 1", RATED SHEATHING, 40/20, 5/8" THICK 3. FLOOR AND ROOF SHEATHING LAYOUT: 3-SPAN CONTINUOUS - MIN, PERP TO FRAMING MEMBERS BRACED WALL PANELS 1.All bearing walls, including unlabeled, hatched BWP's, shall be continuously sheathed as Typical Exterior or Interior Panels, accordingly. 2.Typical Exterior Panels shall be 7/16" APA rated OSB or plywood attached to studs w/ 8d common or galvanized box nails (1 3/8" stud penetration) @ 6"o.c. at panel edges & 12"o.c. at intermediate supports. Block all panel edges. 3.Typical Interior Panels shall be 5/8" gypsum board, both sides of wall, attached to studs w/ 6d cooler nails, 0.120 x 1 3/4", min 3/8" head (or No. 6 1 1/4" Type S or W screws), spaced at 4"o.c. at all supports, studs & plates. Studs shall be spaced @ 24"o.c. max @ panels. Block all panel edges. 4.All hatched BWP's are critical to the current lateral force resisting system design. They shall not be modified. 5.Special BWP's, holdown straps & anchors, as required, are denoted per plans and shall be constructed per schedules shown on these drawings. 6.Where BWP'S are not dimensioned, extend between wall openings or corners as shown on plan. 2'-0" MIN LAP - U.N.O. WOOD AND TIMBER FRAMING 1.All wood and heavy timber construction shall conform to the American Institute of Timber Construction (AITC) and National Design Specification (NDS) Standards, latest edition. 2.Structural framing lumber shall be at a minimum, as noted below, unless noted otherwise, and shall have a maximum moisture content of 19% at time of delivery. SHEATHING NAILING SHEATHING APPLICATION FASTENERS NAIL SPACING COMMENTS@ INTERMEDIATE SUPPORTS @ PANEL EDGES WOOD FLOOR 8d COMMON (0.131 Ø)12"6"GLUED (SEE NOTE 1) WOOD ROOF 8d COMMON (0.131 Ø)12"6"- DBL 2x TOP PL TYP U.N.O. (2) 10d @ CORNER & INTERSECTION LAPS 10d COMMON @ 24"o.c. (2) 10d ADD'L (8) 10d COMMON MIN BTWN SPLICES TYPE SPECIES GRADE Fb (MIN) Existing 2x structural Joists, Rafters & Headers Hem Fir No. 2 850 psi 2x Structural Joists, Rafters & Headers Douglas Fir-Larch No. 2 900 psi 2x Studs, Posts & Plates Douglas Fir-Larch No. 2 900 psi Versa-Stud 1.7E 2,400 psi Plates Douglas Fir-Larch No. 2 900 psi LSL 1.3E 1,700 psi Stringers, Beams & Posts (4x)Douglas Fir-Larch No. 1 1,000 psi Stringers, beams (6x & greater)Douglas Fir-Larch No. 1 1,350 psi Posts (6x & greater)Douglas Fir-Larch No. 1 1,200 psi SPECIAL INSPECTION 1.The owner shall employ a special inspector per IBC Chapter 17. The special inspector shall submit a copy of all his reports to the Owner, Architect, Structural Engineer and the Building Department. When the work is completed, the special inspector shall submit a final signed report stating whether the work was, to the best of his knowledge, in conformance with the approved set of plans and specifications and the applicable workmanship provisions of the building code. The S.E.O.R. will make visits to the site to observe general compliance with the approved structural plans, specifications and change orders. The contractor shall coordinate with the special inspector in order to ensure that the special inspection as indicated below can be performed with minimal impact to the project schedule. 2.Special inspection is required for the following types of work. Refer to Chapter 17 of the 2015 IBC for additional testing and specific requirements. 2.1.All cast-in-place concrete work & reinforcing placement, except nonstructural concrete (periodic). 2.2.All masonry construction (periodic per IBC 1705.4). 2.3.All bolts and embeds in concrete (continuous if wet stabbed, periodic if tied). 2.4.All shop and field welding (periodic). 2.5.All high-strength bolted connections (periodic). SHOP AND ERECTION DRAWINGS 1.The Contractor shall furnish a PDF set of shop and erection drawings for review to the Architect and Structural Engineer of Record prior to fabrication for the following items: 1.1.Wood roof trusses 1.2.Structural Insulated Panels (SIP's) 1.3.Structural steel 1.4.Concrete and masonry reinforcing steel 1.5.Concrete mix designs 1.6.Glazing and intermediate structure per manufacturer for large areas of wall 2.The manufacture, fabrication or erection of above noted items prior to written review by the Architect and Structural Engineer of Record is at the sole risk of the Contractor. A35 OR LS50 CLIP @ KING STUD TO TOP & BOT PL's @ WALL OPNG WIDTH > 4'-0" & (2) A35 OR LS50's @ WIDTH > 7'-0" - TYP U.N.O. 2x SILL PL - USE (2) 2x PL's w/ A35 EA END @ EXT WALL OPNG 8'-0" & GREATER - TYP (1) 2x6 TRIM STUD MIN, TYP U.N.O. PER PLAN (2) 2x6 HDR MIN, TYP U.N.O. PER PLAN (2) 16d COMMON, END NAIL OR (4) 8d COMMON TOENAIL, EA STUD - TYP BOT/SILL PL - SEE PLAN NOTES OR SPECIFIC DETAILS FOR ANCHOR BOLT SIZE & SPACING 2x6 STUDS @ 16"o.c. PER PLAN & DETAILS - U.N.O 2x SOLID BLKG REQ'D AT CEILING LINES & AT ALL EDGES OF EXT WALL SHTG (1) 2x6 KING STUD MIN, TYP U.N.O. PER PLAN (4) 16d COMMON (2) 16d COMMON, END NAIL, TOP PL TO EACH STUD - TYP ABBREVIATIONS TYPICAL FRAMING CONNECTION SCHEDULE (MINIMUM U.N.O.)1, 2 NAILING TYPE Joists or Rafters to T.O. Double Top Plate, Sill Plate or Beam (3) 10d Toenail Rim Joist or Structural Fascia to Joists, Rafters (2) 16d, (1) T&B End Nail Sole Plate to Sill Plate (3) 10d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg - Typ (2) 16d @ 16"o.c.Face Nail Sole Plate to Joist, Rim Joist, Beam or Blkg at BWP (3) 16d @ 16"o.c.Face Nail Double Studs, Built-up Corner Studs, Trim Studs to King Studs1 Per Typ Detail Rim Joist to Top Plate 8d @ 6"o.c.Toenail Blkg Btwn Rafters & Joists to Top Plate, Sill Plate or Beam 8d @ 6"o.c. (3) min per block Toenail 2x Decking to Joists (2) 10d each joist Face Nail 1. Refer to Typical Multiple Ply Beams & Columns Detail for additional information. 2. Refer to Typical Framed Wall Detail for additional information. TYP DBL TOP PL CONN's 57 BAR Ø (24" MIN) 57 B A R Ø (2 4 " M I N ) CORNER INTERSECTION & END OF WALL ALTERNATE CORNER 57 BAR Ø (24" MIN) CORNER BAR AT EA HORIZ BAR - TYP LAP HORIZ BARS EA SIDE OF CORNER - TYP (1) #5 VERT AT END OF WALL OR CORNER - TYP 57 B A R Ø (2 4 " M I N ) ATTACH ALL KING, TRIM STUD & HEADER, BEAM PLIES PER TYP MULTIPLE PLY BM & COL DETAIL FRAMING MEMBERS 12 D R R R = 4D FOR #3 THRU #8 BARS R = 5D FOR #9 THRU #11 BARS R = 6D FOR # 14 AND #18 BARS 90° HOOK 180° HOOK R R 4D OFFSET 57 BAR Ø FOR CONC 64 BAR Ø FOR MASONRY TIED BARS MIN 1.5D OR 1" MAX 1/5 LAP LENGTH OR 6" LAP SPLICE 212" MIN REINFORCED CONCRETE 1.All concrete design is based on the "Building Code Requirements for Reinforced Concrete", ACI 318, latest edition, associated Commentary (ACI 318R), and IRC/IBC Requirements. 2.All structural concrete shall be in accordance with ASTM C39. Minimum compressive strengths noted are required at 28 days, typical unless noted otherwise. 2.1.For structural concrete in buildings of occupancy categories R-2 & R-3: Minimum compressive strength = 3,000 psi. Garage slab and exterior concrete minimum compressive strength = 3,500 psi & air entrained 5-7%. 2.2.Structural concrete for all other structures: Minimum compressive strength = 3,500 psi & maximum w/cm ratio of 0.50. Exposed to freeze-thaw cycles minimum compressive strength = 4500 psi & maximum w/cm ratio of 0.45. Exposed to deicing chemicals = 5000 psi & maximum w/cm ratio of 0.40. 2.3.Stained or polished floor slabs: Minimum compressive strength = 4000 psi with low pozzolanic material ratios. 3.All concrete shall be consolidated using mechanical vibrators. 4.All concrete work shall conform to the requirements of the IBC and ACI Standard 318, latest edition, of the American Concrete Institute (ACI), unless shown or noted otherwise on these drawings. 5.Aggregate shall conform to ASTM C33. 6.Cement shall be ASTM C150, Type I or Type II modified. 7.Concrete shall be placed in accordance with ASTM C94 and ACI Standard 304. 8.All embedded items shall be placed accurately and secured prior to beginning concrete placement. 9.Construction joints shall be located so as not to impair the strength of the structure. Construction joints shall comply with ACI 318, unless noted otherwise. 10.Concrete mix designs shall be submitted to the Architect & S.E.O.R. for approval prior to placement of any concrete. 11.Reinforcement and embedded items shall be free of excessive scale, rust, dirt, grease, & all or any other substance that will impair bond with concrete. REINFORCING STEEL 1.All detailing, fabrication, and placement of reinforcing steel shall be in accordance with the ACI Manual of Concrete Practice. 2.Except where otherwise noted on the Drawings, reinforcing bars shall conform to ASTM Specification A615 and shall be Grade 60. Ties and field-bent bars as noted on plan shall be Grade 40. All reinforcing bars to be welded shall conform to ASTM A706. 3.Welded wire fabric reinforcement shall conform to ASTM A185 and shall be sheet-type; roll-type is not acceptable. 4.Coverage for reinforcing bars shall be in accordance with the requirements of the IBC, the ACI Standard 318 and in the Table below, unless shown otherwise on the Drawings. 5.Lap splices for reinforcing bars shall be 57 bar diameters (24" minimum) for concrete reinforcement and 72 bar diameters (36" minimum) for masonry reinforcement unless shown otherwise on the Drawings. Wire bars together at laps or splices. Stagger laps in adjacent horizontal bars a minimum of the required splice length. Hooks shall be ACI standard hooks unless shown otherwise. Welded wire fabric shall be spliced by lapping a minimum of 12 inches, or (2) cross wires, whichever is greater. STRUCTURAL STEEL 1.All detailing, fabrication, and erection of structural and miscellaneous steel shall be in accordance with the requirements of the American Institute of Steel Construction (AISC) Code of Standard Practice, latest edition, and the American Welding Society (AWS) Specifications. 2.All structural steel rolled shapes, except angles and plates, shall conform to ASTM A992, 50 ksi. 3.Angles, channels & plates shall conform to ASTM A36, 36 ksi, unless otherwise noted on the Drawings. 4.Pipes shall conform to ASTM A53, Grade B, 35 ksi. 5.Tube shapes (HSS) shall conform to ASTM A500, Grade B, rectangular shapes = 46 ksi & round shapes = 42 ksi. 6.All bolts for steel-to-steel connections shall conform to ASTM A325, unless otherwise noted on the Drawings. 7.All anchor bolts shall conform to ASTM F1554 Gr. 36, unless otherwise noted on the Drawings. 8.All shear studs shall conform to ASTM A108 & shall be welded to steel beams for full shear capacity. 9.All welding shall be in accordance with the requirements of the IBC and the Structural Welding Code, AWS D1, latest edition, by the American Welding Society. Shop welding shall be performed in shops approved by the Building Official, per IBC. Welding shall be done using E70XX electrodes, unless noted otherwise on the Drawings. 10.Expansion bolts and epoxy anchors called for on the Drawings shall be Hilti or approved equivalent, with embedment as shown on the Drawings. Expansion bolts shall be Hilti Kwik Bolt 3. 11.Powder actuated fasteners shall be Hilti DNI or approved equivalent, with full penetration into steel members, unless otherwise noted on the Drawings. 12.Steel, including bolts & anchors, in contact with earth, or as otherwise noted on the Drawings, shall be hot dip galvanized or prime painted. Do not paint within 3" of field welds until welds are completed. MINIMUM CONCRETE COVER FOR REINFORCEMENT1 CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" CONCRETE EXPOSED TO EARTH OR WEATHER No. 6 thru No. 18 bars 2" No. 5 bar, W31 or D31 wire, and smaller 1 1/2" CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND Slabs, Walls, Joists:No. 14 and No. 18 bars 1 1/2 " No. 11 bar and smaller 3/4" Beams, Columns:Primary reinforcement, ties, stirrups, spirals 1 1/2" 1.Minimum concrete cover specified or for cast-in-place, nonprestressed concrete DESIGN LOADS 1.ROOF LOADS Dead Load .......................................15 psf Live Load (Snow).............................75 psf (per 2016 SEAC Snow Load Data Report w/ Site Elevation = 7,900', K = ?, Ground Snow Load = ? psf) 2.FLOOR LOADS Dead Load .......................................15 psf Live Load .........................................40 psf 3.LATERAL LOADS Seismic Design Category.................C Basic Wind Speed ...........................115 mph Exposure Category .........................B Importance Factor ...........................1.0 * No duration of load increase was used in design FOUNDATIONS 1.Concrete foundations are designed based on the following assumed soil values (full dead load plus full live load, placed on natural soils and/or engineered structural fill per soils engineer). Soil Density = 120 pcf (Assumed) Allowable Bearing Pressure = 2,000 psf (Assumed) Lateral At-Rest Earth Pressure = 50 pcf (Assumed) Lateral Active Earth Pressure = 45 pcf (Assumed) Lateral Passive Earth Pressure = 350 pcf (Ultimate) Coefficient of Friction for Footing = 0.50 (Ultimate) Frost Depth = 42" min 2.Soils conditions and types, at the proposed foundation bearing elevations, shall be verified as adequate for the noted soil values, by a representative of a qualified Geotechnical Engineer (employed by Owner) during excavation. 3.Proper surface and below grade perimeter drainage shall be installed per Civil & Geotechnical Engineers to relieve foundations from hydrostatic pressures. 4.It is the responsibility of the Contractor to review the Geotechnical Engineer's recommendations and notify the Architect and/or S.E.O.R. if any changes to the design are required prior to start of construction. SCALE: NTS1TYP FLOOR & ROOF SHEATHING SCALE: NTS5TYP REINF DETAILS SCALE: NTS4TYP REINF AT CONC WALLS SCALE: 3/4" = 1'-0"2 TYP WALL FRAMING DETAIL SCALE: NTS3TYP MULTI-PLY BEAMS & COLUMNS MASONRY 1.Concrete masonry units (CMU's) shall conform to ASTM C90, Grade N, and shall have a minimum 28 day compressive strength of 1900 psi. 2.Compressive strength of masonry construction (F'm) shall be 1500 psi minimum based on net compressive area. 3.Mortar for CMU's shall be Type M or Type S, ASTM C270. Admixtures shall not be used unless approved by the Architect. The use of masonry cement is not permitted. Minimum compressive cube strength shall be 1900 psi. 4.Grout used in masonry construction shall be coarse grout, and shall conform to ASTM C476. Grout shall develop a minimum compressive strength of 3000 psi at 28 days. 5.Reinforce all masonry walls with continuous horizontal 9 gauge ladder or truss type reinforcement meeting ASTM A82. Maximum vertical spacing of joint reinforcing shall be 16 inches. 6.All walls shall be reinforced vertically at wall ends, corners, each side of door or window openings, and as otherwise noted on plans. Provide continuous horizontal bond beams at top of walls and as otherwise noted. 7.All block shall be laid up in running bond. 8.Grout shall be consolidated by mechanical vibration during placement. Grout pours less than 12" may be puddled for consolidation. 9.All bolts, anchors and embedded items shall be grouted in place, unless otherwise noted on the Drawings. Anchor bolts shall have at least 1 inch of grout between the bolt and the masonry shell, and shall be headed or hooked. 57 BAR Ø (24" MIN) GROUT, ADHESIVE & EPOXY 1.All grout beneath column base plates, or steel beams at bearing shall be non-metallic, non-shrink high strength grout by BASF "Masterflow", or approved equal installed to manufacturer's specifications. 2.All structural construction adhesive specified shall be Loctite PL Premium Fast Grab or approved equal & shall be installed to manufacturer's specifications. 3.Epoxy shall be Hilti HIT-HY 200 or approved equivalent, unless otherwise noted on the Drawings. 3.Provide solid blocking at supports between joists and rafters. Within floor joist spaces beneath solid or built-up posts, provide solid blocking with area same as post above. 4.All plywood shown on these drawings shall be minimum C-D grade with exterior glue in accordance with DOC PS 1 and comply with IBC. 5.Sill plates shall be of naturally durable wood, or Zinc Borate treated LSL or Douglas Fir-Larch per IBC with Fc perp = 625 psi, minimum and shall be protected for dry use. 6.All wood framing shall be preservative pressure treated when in contact with concrete or masonry foundation or exposed to exterior conditions. All fasteners used to connect pressure-treated wood shall be hot-dipped galvanized (HDG) or stainless steel. 7.Except as noted otherwise, provide minimum nailing as specified in IBC. Structural nailing shall be with common nails, unless otherwise noted on the Drawings. Nails exposed to weather shall be galvanized. Nails used to connect preservative treated wood shall be hot dipped galvanized (HDG) or stainless steel. 8.Metal timber connectors shall be Simpson Strong-Tie or equivalent. Hardware specified is for specific member size & manufacturer as show on the structural drawings. Hanger slope, skew & top flange shall be designated by the contractor as required. Simpson connectors for preservative treated wood or connectors in contact with concrete shall be ZMAX or HDG, or as otherwise recommended by specific connector supplier. Install all connectors in accordance with manufacturer's instructions for maximum rated loads. 9.Bolts used as timber-to-steel or timber-to-timber connectors shall be ASTM A307 unless noted otherwise on the Drawings. Bolts shall be installed in accordance with the requirements of the latest edition of the National Design Specification for Wood Construction (NDS) by the American Wood Council. Bolts used to connect pressure-treated wood shall be HDG or stainless steel. 10.Lag screws shall be ASTM A307. Holes for lag screws shall be bored the same depth and diameter as the bolt shank. The remaining depth of penetration shall be bored per NDS requirements. Lag screws used to connect pressure-treated wood shall be HDG or stainless steel. 11.Provide malleable iron washers or equivalent cut plate washers under all nuts, bolts or lag screw heads which bear on wood. 12.Wood screws shall be steel per NDS requirements. Pre-drill holes to prevent splitting as recommended in the NDS. 13.Wood members shall be cut or notched only as shown on the Structural Drawings. 14.Provide cross bridging, solid bridging or other lateral support for all framing members in accordance with the requirements of IBC. 15.Except where more stringent construction is shown on the Drawings, wood construction shall comply with the requirements of the IBC, latest edition, as a minimum. AB ANCHOR BOLT ABV ABOVE ACI AMERICAN CONCRETE INSTITUTE ADDL ADDITIONAL ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR ALT ALTERNATE APA AMERICAN PLYWOOD ASSOC ARCH ARCHITECT OR ARCHITECTURAL B.O.BOTTOM OF BLDG BUILDING BLKG BLOCKING BLW BELOW BM BEAM BOT BOTTOM BOW BOTTOM OF WALL BRG BEARING BTWN BETWEEN BWP BRACED WALL PANEL CANTD CANTILEVERED CCW COUNTER-CLOCKWISE CIP CAST-IN-PLACE CJ CONTROL JOINT CJP COMPLETE JOINT PENETRATION CL CENTERLINE CLR CLEAR CMU CONCRETE MASONRY UNIT CNTRD CENTERED COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CW CLOCKWISE DBA DEFORMED BAR ANCHOR DEFL DEFLECTION DIAG DIAGONAL DL DEAD LOAD E.F.EACH FACE E.N.EDGE NAILING E.W.EACH WAY EL ELEVATION ELEV ELEVATOR EMBED EMBEDMENT EQ EQUAL EQUIV EQUIVALENT EXISTG/(E)EXISTING EXP EXPANSION EXT EXTERIOR F.D.FLOOR DRAIN FDN FOUNDATION FLG FLANGE FS FULL SAWN FTG FOOTING G.C.GENERAL CONTRACTOR GA GAUGE/GAGE GALV GALVANIZED, HOT DIP GB GRADE BEAM GL GLUE-LAMINATED MEMBER H.A.S.HEADED ANCHOR STUD HDR HEADER HGR HANGER HORIZ HORIZONTAL HSS HOLLOW STRUCTURAL STEEL HT HEIGHT I.F.INSIDE FACE IBC INTN'L BUILDING CODE INT INTERIOR IRC INTN'L RESIDENTIAL CODE ISO ISOLATION JST JOIST JT JOINT K KING KSI KIPS PER SQUARE INCH LL LIVE LOAD LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LOC LOCATION LT LIGHT LVL LAMINATED VENEER LUMBER MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MF MOMENT FRAME MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MTL METAL N.S.NOT SHOWN NTS NOT TO SCALE o.c.ON-CENTER O.F.OUTSIDE FACE OPNG OPENING OPP OPPOSITE OSB ORIENTED STRAND BOARD P.E.PRE-ENGINEERED P.T.PRESSURE TREATED PAF POWER-ACTUATED FASTENER PC PRE CAST PEN PENETRATION PERP PERPENDICULAR PL PLATE PLCS PLACES PLF POUNDS PER LINEAR FOOT PLL PARALLEL PLY PLYWOOD PSF POUNDS PER SQUARE FOOT PSL PARALLEL STRAND LUMBER R RADIUS R.D.ROOF DRAIN RE:REFER TO REINF REINFORCING/MENT REQD REQUIRED RS ROUGH SAWN RTU ROOF TOP UNIT S.O.G.SLAB ON GRADE SCHED SCHEDULE SEOR STRUCTURAL ENGR OF RECORD SHT SHEET SHTG SHEATHING SIM SIMILAR SP SPACE OR SPACING SPECS SPECIFICATIONS SS STAINLESS STEEL STD STANDARD STGD STAGGERED STL STEEL STRUCT STRUCTURAL SYM SYMMETRICAL T TRIMMER T&B TOP AND BOTTOM T&G TONGUE AND GOOVE T.O.TOP OF TOF TOP OF FOOTING TOL TOP OF LEDGE TOS TOP OF SLAB TOW TOP OF WALL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VERT VERTICAL VIF VERIFY IN FIELD w/WITH WP WORK POINT WWF WELDED WIRE FABRIC EXISTING FLOOR JOIST OR ROOF RAFTER EXISTING FLUSH BEAM EXISTING DROPPED BEAM EXISTING HEADER BEAM OR LINTEL STRUCTURAL SYMBOLS LEGEND EXISTING MASONRY WALL & CONCRETE FOOTING CONCRETE WALL & FOOTING EXISTING CONCRETE WALL & FOOTING EXISTING LEDGER EXISTING WALL BELOW FRAMING TO BE REMOVED EXISTING BEARING STUD WALL BELOW FRAMING EXISTING ROOF RAFTER OR FLOOR JOIST SPAN, ARROWS DESIGNATE BEARING LOCATIONS ROOF OVERFRAMING PER TYPICAL DETAIL X STEEL OR WOOD COLUMN WHICH SUPPORTS FRAMING OR LOADS FROM ABOVE SEE WALL FRAMING NOTES FOR MIN SIZE, NUMBER, & TYPE FLOOR JOIST OR ROOF RAFTER JOIST HANGER OR BEAM TO BEAM CONNECTION RE: HANGER SCHEDULE FOR CONNECTION, U.N.O. FLUSH BEAM VERTICAL STEP IN FLOOR WOOD STUD STRUCTURAL WALL ABOVE NON-BEARING STUD WALL BELOW FRAMING REVISION CLOUD INDICATING REVISED ITEMS REVISION NUMBER CORRESPONDS WITH REVISIONS IN TITLE BLOCK STEEL OR WOOD COLUMN FROM ABOVE OR BTWN BEAMS WHICH ARE SUPPORTED ON FRAMING, MIN WIDTH TO MATCH SUPPORTED FRAMING, U.N.O. ROOF RAFTER OR FLOOR JOIST SPAN, ARROWS DESIGNATE BEARING LOCATIONS DROPPED BEAM HEADER BEAM OR LINTEL WALL STEP, POINTS IN DIRECTION OF DOWN MASONRY WALL & CONCRETE FOOTING LEDGER BEARING STUD WALL BELOW FRAMING MOMENT CONNECTION BRACED WALL PANEL (BWP) & BEARING WALL BELOW FRAMING HOLDOWN FRAMING OR FOUNDATION ANCHOR PER PLAN & SCHEDULE EXISTING STEEL OR WOOD COLUMN TO BE REMOVED EXISTING FRAMING TO BE REMOVED EXISTING VERTICAL STEP IN FLOOR EXISTING WALL STEP, POINTS IN DIRECTION OF DOWN HOLDOWNS INSTALLED AT BASE OF WALL PANEL ABOVE BRACED WALL PANEL (BWP) & NON-BEARING WALL BELOW FRAMING S1 H1 EXISTING BRACED WALL PANEL (BWP) & BEARING WALL BELOW FRAMING STONE VENEER DATE:ISSUE: 11/15/19 HPC SUBMIT PLOT DATE: 11/15/2019 PROJECT # : 19.121C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 DI M I T R I U S R E S I D E N C E 12 5 W M A I N S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 NOT FOR CONSTRUCTION S0.001 GENERAL NOTES & TYP DETAILS A B C 1 1 1 1 1 A.1 B.1 C TOS = 90'-3" TOS = 92'-3" TOS = 92'-3" TOW=91'-11" TOF=89'-9" TOF=89'-9" 8" WINDOW WELL WALL w/ #5 @ 12"o.c. EA WAY CTRD 16"W x 10" DP FT w/ (2) #5 CONT BOT8" RETAINING WALL w/ #5 @ 12"o.c. EA WAY CTRD - TYP 6'-0" SQ x 14" DP w/ (7) #6 EA WAY BOT (E) FDN TO REMAIN TYP - V.I.F. BOT OF (E) FOOTING INFILL CONC CURB AT (E) OPENING TOW=V.I.F. 1 S6.001 X SX.X V.I.F. NEW SHELF SLAB ELEVATION - TYP X SX.X X SX.X 3'-6" TYP FOUNDATION NOTES: 1.REFER TO SHEET S0.001 FOR GENERAL NOTES. 2.SEE FRAMING PLANS ABOVE FOR COLUMN & POST LOCATIONS & SIZES. 3.CONCRETE FOOTINGS & THICKENED SLABS SHALL BE PER PLAN & SCHEDULE ON S1.0. 4.ALL CONCRETE WALLS SHALL BE CENTERED ON FOOTINGS - U.N.O. 5.SEE X/S2.0 FOR ALL CONCRETE REINFORCING STANDARD HOOKS AND BENDS. 6.PROPER SURFACE & BELOW GRADE PERIMETER DRAINAGE SHALL BE INSTALLED PER CIVIL & GEOTECHNICAL ENGINEERS TO RELIEVE FOUNDATION WALLS FROM HYDROSTATIC PRESSURES. 7.REFER TO SHEET S2.0 FOR TYPICAL CONCRETE DETAILS. 8.DO NOT PLACE BACKFILL AGAINST BASEMENT WALLS UNTIL ALL SUPPORTING ELEMENTS, INCLUDING MAIN LEVEL FLOOR SHEATHING, ARE IN PLACE AND SECURELY ANCHORED, OR UNTIL ADEQUATE TEMPORARY SHORING IS INSTALLED. 9.ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS & FIELD VERIFIED BY CONTRACTOR. 10.SOILS CONDITIONS TO BE VERIFIED IN FIELD AT OPEN HOLE BY SOILS ENGINEER PER FOUNDATIONS NOTES ON S0.0. 11.ANCHOR ALL SILL PLATES TO TOP OF CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT AT 6'-0" MAXIMUM, 2 ANCHORS MINIMUM PER PLATE, 4" FROM EACH END, U.N.O.. REFER TO BWP SCHEDULE FOR ATYPICAL A.B.'S AND SPACINGS, REFER TO PLANS ABOVE FOR LOCATIONS 12.REFER TO PLANS AND SCHEDULE FOR ALL HOLDOWN ANCHORS BETWEEN FRAMING AND INTO CONCRETE. REFER TO PLANS ABOVE FOR SPECIFICATIONS. 13.ISOLATE ALL SLABS-ON-GRADE FROM STRUCTURAL ELEMENTS WITH EXPANSION JOINT MATERIAL - U.N.O. DATE:ISSUE: 11/15/19 HPC SUBMIT PLOT DATE: 11/15/2019 PROJECT # : 19.121C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 DI M I T R I U S R E S I D E N C E 12 5 W M A I N S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 NOT FOR CONSTRUCTION FOUNDATION PLAN SCALE: 1 4" = 1'-0"A S2.001 FOUNDATION PLAN A B C 1 1 1 1 1 A.1 B.1 C T.O. (E) PLY = 99'-111 4" NEW WINDOW WELL BELOW X SX.X OVERFRAME FLOOR TBD - TYP V.I.F. (E) 2x8 @ 16"o.c. TO REMAIN 71 4" LVL SISTERED TO EA JST TYP AS SHOWN 71 4" LVL SISTERED TO EA JST TYP AS SHOWN NEW BEARING WALLS AS SHOWN - SHIM TIGHT TO (E) JSTS TYP V.I.F. FRAMING ALIGNMENT AT CENTER BEARING LINE TYP ROOF TO FDN ALL EXISTING STRUCTURE IS TO REMAIN - U.N.O. CONTRACTOR SHALL FIELD VERIFY ALL NOTED EXISTING STRUCTURE PRIOR TO CONSTRUCTION AND SHALL NOTIFY THE E.O.R. OF ANY DISCREPANCIES IT IS RECOMMENDED THAT ALL DAMAGED STRUCTURE BE RETROFIT WITH NEW FRAMING. NOTIFY S.E.O.R. OF EXISTING CONDITIONS FOR RETROFIT DESIGN PRIOR TO PROCEEDING WITH REPAIRS. INFILL FRAME (E) STAIR BELOW - V.I.F. JOIST HGRS TBD - TYP W8 x 6 7 ( 9 9 ' - 1 0 12") W8 x 6 7 ( 9 9 ' - 1 0 12") ROOF & FLOOR FRAMING NOTES: 1.REFER TO SHEET S0.0 FOR GENERAL NOTES AND DETAILS, INCLUDING: - FLOOR & ROOF SHEATHING PER 1/S0.0. - TYPICAL WALL FRAMING PER 2/S0.0. - ATTACHMENT OF MULTI-PLY COLUMNS & BEAMS PER 3/S0.0. - ROOF OVERFRAMING, HATCHED PER PLAN, PER 4/S0.0. - ALL TYPICAL FRAMING CONNECTIONS PER SCHEDULE ON S0.0. 2.ALL COLUMNS SHOWN SHALL BE (2) 2x6, TYP - U.N.O. 3.ALL BEARING WALL HEADERS SHALL BE (2) 2x6, TYP - U.N.O. 4.ALL INTERIOR & EXTERIOR BEARING WALLS ARE 2x6 STUDS AT 16"o.c., TYP - U.N.O.. 5.ALL INTERIOR & EXTERIOR BEARING WALLS SHALL BE SHEATHED PER BRACED WALL PANEL NOTES ON S0.0, TYP - U.N.O. a. SPECIAL BRACE WALL PANELS PER SCHEDULE AND PLAN. b. ANY WALL OPENINGS TO BE MODIFIED SHALL BE APPROVED BY THE S.E.O.R. 6.ALL FRAMING MATERIAL EXPOSED TO WEATHER SHALL BE PRESERVATIVE PRESSURE TREATED PER S0.0 - U.N.O. 7.REFER TO S1.0 FOR ALL HOLDOWN ANCHORS. 8.ALL DEAD LOAD SHALL BE APPLIED TO STRUCTURE PRIOR TO INSTALLING WINDOWS & DOORS. 9.SHOP DRAWINGS FOR LARGE AREAS OF GLAZING SHALL BE PROVIDED TO S.E.O.R. FOR REVIEW PRIOR TO FABRICATION TO COORDINATE CONNECTIONS & LOADING WITH MAIN BUILDING STRUCTURE. 10.ANCHOR ALL SILL PLATES TO TOP OF CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT AT 4'-0" MAXIMUM, 2 ANCHORS MINIMUM PER PLATE, 3" FROM EACH END, U.N.O.. REFER TO BWP SCHEDULE FOR ATYPICAL A.B.'S AND SPACINGS, REFER TO PLANS ABOVE FOR LOCATIONS. 11.ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS & FIELD VERIFIED BY CONTRACTOR. DATE:ISSUE: 11/15/19 HPC SUBMIT PLOT DATE: 11/15/2019 PROJECT # : 19.121C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 DI M I T R I U S R E S I D E N C E 12 5 W M A I N S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 NOT FOR CONSTRUCTION S2.002 MAIN FLOOR FRAMING PLAN MAIN FLOOR FRAMING PLAN SCALE: 1 4" = 1'-0"A ROOF & FLOOR FRAMING NOTES: 1.REFER TO SHEET S0.0 FOR GENERAL NOTES AND DETAILS, INCLUDING: - FLOOR & ROOF SHEATHING PER 1/S0.0. - TYPICAL WALL FRAMING PER 2/S0.0. - ATTACHMENT OF MULTI-PLY COLUMNS & BEAMS PER 3/S0.0. - ROOF OVERFRAMING, HATCHED PER PLAN, PER 4/S0.0. - ALL TYPICAL FRAMING CONNECTIONS PER SCHEDULE ON S0.0. 2.ALL COLUMNS SHOWN SHALL BE (2) 2x6, TYP - U.N.O. 3.ALL BEARING WALL HEADERS SHALL BE (2) 2x6, TYP - U.N.O. 4.ALL INTERIOR & EXTERIOR BEARING WALLS ARE 2x6 STUDS AT 16"o.c., TYP - U.N.O.. 5.ALL INTERIOR & EXTERIOR BEARING WALLS SHALL BE SHEATHED PER BRACED WALL PANEL NOTES ON S0.0, TYP - U.N.O. a. SPECIAL BRACE WALL PANELS PER SCHEDULE AND PLAN. b. ANY WALL OPENINGS TO BE MODIFIED SHALL BE APPROVED BY THE S.E.O.R. 6.ALL FRAMING MATERIAL EXPOSED TO WEATHER SHALL BE PRESERVATIVE PRESSURE TREATED PER S0.0 - U.N.O. 7.REFER TO S1.0 FOR ALL HOLDOWN ANCHORS. 8.ALL DEAD LOAD SHALL BE APPLIED TO STRUCTURE PRIOR TO INSTALLING WINDOWS & DOORS. 9.SHOP DRAWINGS FOR LARGE AREAS OF GLAZING SHALL BE PROVIDED TO S.E.O.R. FOR REVIEW PRIOR TO FABRICATION TO COORDINATE CONNECTIONS & LOADING WITH MAIN BUILDING STRUCTURE. 10.ANCHOR ALL SILL PLATES TO TOP OF CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT AT 4'-0" MAXIMUM, 2 ANCHORS MINIMUM PER PLATE, 3" FROM EACH END, U.N.O.. REFER TO BWP SCHEDULE FOR ATYPICAL A.B.'S AND SPACINGS, REFER TO PLANS ABOVE FOR LOCATIONS. 11.ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS & FIELD VERIFIED BY CONTRACTOR. A B C 1 1 1 1 1 A.1 B.1 C T.O. (E) PLY = 110'-71 4"T.O. PLY = 108'-77 8" T.O. PLY = 108'-77 8" (E) RAFTERS V.I.F. NE W R A F T E R T B D NE W R A F T E R T B D INFILL FRAME AT OLD SKYLIGHT LOCATION V.I.F. FRAMING ALIGNMENT AT CENTER BEARING LINE - TYP ROOF TO FDN 91 2" LVL @ 16"o.c. - TYP @ NEW FLR FULL DEPTH LVL BLK'G UNDER BRG WALL ABOVE - TYP 912" LVL LEDGER w/ (3) 1 4"Ø x 412" SDS SCREWS @ 16"o.c. TO EA STUD V.I.F. WALL FRAMING CONFIGURATION AT ATTIC PRIOR TO REMOVING (E) ATTIC FLOOR - TYP (E) JSTS - V.I.F. (3 ) 7 1 4" L V L HU C 6 8 (3) 71 4" LVL (3) 71 4" LVL HSS 4 x 4 ALL EXISTING STRUCTURE IS TO REMAIN - U.N.O. CONTRACTOR SHALL FIELD VERIFY ALL NOTED EXISTING STRUCTURE PRIOR TO CONSTRUCTION AND SHALL NOTIFY THE E.O.R. OF ANY DISCREPANCIES IT IS RECOMMENDED THAT ALL DAMAGED STRUCTURE BE RETROFIT WITH NEW FRAMING. NOTIFY S.E.O.R. OF EXISTING CONDITIONS FOR RETROFIT DESIGN PRIOR TO PROCEEDING WITH REPAIRS. W8 x 2 1 ( 1 0 8 ' - 5 5 8") (3 ) 9 1 2" L V L (E) JSTS - V.I.F. (E) JSTS - V.I.F. JOIST HGRS TBD - TYP (4) 2 x 6 (3) 2 x 6 (3) 2 x 6 (4) 2 x 6 BEAR LVL BM ON STUD PACK DOWN TO STL BELOW (2) 51 2" LVL HDR MIN (3) 51 2" LVL HDR MIN (3) 2 x 6 (3) 2 x 6 (3) 51 2" LVL HDR MIN DATE:ISSUE: 11/15/19 HPC SUBMIT PLOT DATE: 11/15/2019 PROJECT # : 19.121C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 DI M I T R I U S R E S I D E N C E 12 5 W M A I N S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 NOT FOR CONSTRUCTION S2.003 UPPER FLOOR FRAMING PLAN UPPER FLOOR FRAMING PLAN SCALE: 1 4" = 1'-0"A ROOF & FLOOR FRAMING NOTES: 1.REFER TO SHEET S0.0 FOR GENERAL NOTES AND DETAILS, INCLUDING: - FLOOR & ROOF SHEATHING PER 1/S0.0. - TYPICAL WALL FRAMING PER 2/S0.0. - ATTACHMENT OF MULTI-PLY COLUMNS & BEAMS PER 3/S0.0. - ROOF OVERFRAMING, HATCHED PER PLAN, PER 4/S0.0. - ALL TYPICAL FRAMING CONNECTIONS PER SCHEDULE ON S0.0. 2.ALL COLUMNS SHOWN SHALL BE (2) 2x6, TYP - U.N.O. 3.ALL BEARING WALL HEADERS SHALL BE (2) 2x6, TYP - U.N.O. 4.ALL INTERIOR & EXTERIOR BEARING WALLS ARE 2x6 STUDS AT 16"o.c., TYP - U.N.O.. 5.ALL INTERIOR & EXTERIOR BEARING WALLS SHALL BE SHEATHED PER BRACED WALL PANEL NOTES ON S0.0, TYP - U.N.O. a. SPECIAL BRACE WALL PANELS PER SCHEDULE AND PLAN. b. ANY WALL OPENINGS TO BE MODIFIED SHALL BE APPROVED BY THE S.E.O.R. 6.ALL FRAMING MATERIAL EXPOSED TO WEATHER SHALL BE PRESERVATIVE PRESSURE TREATED PER S0.0 - U.N.O. 7.REFER TO S1.0 FOR ALL HOLDOWN ANCHORS. 8.ALL DEAD LOAD SHALL BE APPLIED TO STRUCTURE PRIOR TO INSTALLING WINDOWS & DOORS. 9.SHOP DRAWINGS FOR LARGE AREAS OF GLAZING SHALL BE PROVIDED TO S.E.O.R. FOR REVIEW PRIOR TO FABRICATION TO COORDINATE CONNECTIONS & LOADING WITH MAIN BUILDING STRUCTURE. 10.ANCHOR ALL SILL PLATES TO TOP OF CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS WITH MINIMUM 7" EMBEDMENT AT 4'-0" MAXIMUM, 2 ANCHORS MINIMUM PER PLATE, 3" FROM EACH END, U.N.O.. REFER TO BWP SCHEDULE FOR ATYPICAL A.B.'S AND SPACINGS, REFER TO PLANS ABOVE FOR LOCATIONS. 11.ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS & FIELD VERIFIED BY CONTRACTOR. A B C 1 1 1 1 1 A.1 B.1 C (E) PORCH ROOF BELOW TO REMAIN (E) LOW ROOF BELOW RELOCATED SKYLIGHT BELOW ALL EXISTING STRUCTURE IS TO REMAIN - U.N.O. CONTRACTOR SHALL FIELD VERIFY ALL NOTED EXISTING STRUCTURE PRIOR TO CONSTRUCTION AND SHALL NOTIFY THE E.O.R. OF ANY DISCREPANCIES (3 ) 7 1 4" L V L - 2 S P A N (3 ) 5 12" L V L (3 ) 5 1 2" L V L (3 ) 5 1 2" L V L (3 ) 5 12" L V L 512" LVL SISTERED TO EA RAFTER TYP AS SHOWN (E) SLOPED CLG - V.I.F. FRAMING CONFIGURATION V.I.F. HIP RAFTER FRAMING & SUBMIT TO S.E.O.R. FOR RETROFIT DETAILING - TYP V.I.F. COLLAR TIED RAFTER FRAMING & SUBMIT TO S.E.O.R. FOR RETROFIT DETAILING - TYP V.I.F. FRAMING ALIGNMENT AT CENTER BEARING LINE - TYP ROOF TO FDN IT IS RECOMMENDED THAT ALL DAMAGED STRUCTURE BE RETROFIT WITH NEW FRAMING. NOTIFY S.E.O.R. OF EXISTING CONDITIONS FOR RETROFIT DESIGN PRIOR TO PROCEEDING WITH REPAIRS. DATE:ISSUE: 11/15/19 HPC SUBMIT PLOT DATE: 11/15/2019 PROJECT # : 19.121C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 DI M I T R I U S R E S I D E N C E 12 5 W M A I N S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 NOT FOR CONSTRUCTION S2.004 ROOF FRAMING PLAN ROOF FRAMING PLAN SCALE: 1 4" = 1'-0"A SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"1 FDN SECTION RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX SCALE: 3/4" = 1'-0"X XXX RE: SX.XXX V.I.F. B.O. (E) FDN NEW SHELF SLAB TO BRACE (E) FDN - COORD SHELF ELEV w/ (E) B.O. FDN ELEV. NEW RETAINING WALL TO BRACE (E) FDN (E) STONE AND CONCRETE FDN V.I..F (E) CRAWL SPACE GRADE - V.I.F. UNDISTURBED NATIVE SOIL NEW BASEMENT SLAB PER PLAN T.O. FTG PER PLAN PER PLAN T.O. WALL DATE:ISSUE: 11/15/19 HPC SUBMIT PLOT DATE: 11/15/2019 PROJECT # : 19.121C DRAWN BY : SE CHECKED BY : SE STRUCTURAL DESIGN www.evolvestruct.com 1040 Main Street Carbondale, CO 81623 (970) 510-0773 DI M I T R I U S R E S I D E N C E 12 5 W M A I N S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 NOT FOR CONSTRUCTION S6.001 FRAMING DETAILS