HomeMy WebLinkAbout22322-205WMain-UnitResidential Calculation - 205 W. MAIN
2020 NFPA 70 ART. 220 PART IV
2020 NEC 220.82(B)
1200 SQFT Main Level
1200 SQFT General Lighting Load 3600 VA
2 CCT Small Appliance 3000 VA
1 CCT Laundry Circuit 1500 VA
Total General Load:8100 VA General Lighting Load:8100 VA
Appliance Loads:
1 Refrigerator 600 VA
1 Dishwasher 1200 VA
1 Disposal 900 VA
1 Microwave 1200 VA
3900 VA Appliance Load:3900 VA
Dryer Loads:
1 Electric Dryer 5000 VA Electric Dryer Load: 5000 VA
Oven loads:
1 Electric Oven 9600 VA Electric Oven Load:9600 VA
Other Loads:
0 VA 125% LARGEST MOTOR:300 VA
Total Other Load:0 VA
Subtotal General Loads:26900 VA
10000 VA @ 100%10000 VA
16900 VA @ 40%6760 VA
2020 NEC 220.82(C)16760 VA
Equipment Power Equipment Power
Baseboard Heat 3000 VA
Baseboard Heat 3000 VA Heating Loads:9000 VA
Baseboard Heat 3000 VA Cooling Loads:0 VA
Connected:9000 VA Greater of Noncoincidental Loads:9000 VA
208 V CONNECTED:35900 VA DEMAND:25760 VA
1 Ø 172.6 A 123.8 A
Heating LoadsCooling Loads