Loading...
HomeMy WebLinkAbout22322-205WMain-UnitResidential Calculation - 205 W. MAIN 2020 NFPA 70 ART. 220 PART IV 2020 NEC 220.82(B) 1200 SQFT Main Level 1200 SQFT General Lighting Load 3600 VA 2 CCT Small Appliance 3000 VA 1 CCT Laundry Circuit 1500 VA Total General Load:8100 VA General Lighting Load:8100 VA Appliance Loads: 1 Refrigerator 600 VA 1 Dishwasher 1200 VA 1 Disposal 900 VA 1 Microwave 1200 VA 3900 VA Appliance Load:3900 VA Dryer Loads: 1 Electric Dryer 5000 VA Electric Dryer Load: 5000 VA Oven loads: 1 Electric Oven 9600 VA Electric Oven Load:9600 VA Other Loads: 0 VA 125% LARGEST MOTOR:300 VA Total Other Load:0 VA Subtotal General Loads:26900 VA 10000 VA @ 100%10000 VA 16900 VA @ 40%6760 VA 2020 NEC 220.82(C)16760 VA Equipment Power Equipment Power Baseboard Heat 3000 VA Baseboard Heat 3000 VA Heating Loads:9000 VA Baseboard Heat 3000 VA Cooling Loads:0 VA Connected:9000 VA Greater of Noncoincidental Loads:9000 VA 208 V CONNECTED:35900 VA DEMAND:25760 VA 1 Ø 172.6 A 123.8 A Heating LoadsCooling Loads