Loading...
HomeMy WebLinkAboutExhibitB ApprovedApplicationScale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A 0.1 10/26/20 GENERAL INFORMATION DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 CONTRACTOR - - STRUCTURAL ENGINEER - - CIVIL ENGINEER - - MECHANICAL ENGINEER G.1.01 GENERAL INFORMATION A.1.01 EXISTING: SITE PLAN A.1.02 PROPOSED: SITE PLAN A.1.03 PROPOSED: LANDSCAPE PLAN A.1.04 EXISTING: FAR CALCULATIONS A.1.05 PROPOSED: FAR CALCULATIONS A.2.00 EXISTING: MAIN LEVEL PLAN A.2.01 EXISTING: ROOF PLAN A.2.02 PROPOSED: LOWER LEVEL PLAN A.2.03 PROPOSED: MAIN LEVEL PLAN A.2.04 PROPOSED: UPPER LEVEL PLAN A.2.05 PROPOSED: ROOF PLAN A.3.01 EXISTING ELEVATIONS: NORTH & EAST A.3.02 EXISTING ELEVATIONS: SOUTH & WEST A.3.03 PROPOSED ELEVATIONS: NORTH & EAST A.3.04 PROPOSED ELEVATIONS: SOUTH & WEST A.4.01 EXISTING BUILDING SECTIONS A.4.02 EXISTING BUILDING SECTIONS A.4.03 EXISTING BUILDING SECTIONS A.4.04 PROPOSED BUILDING SECTIONS A.4.05 PROPOSED BUILDING SECTIONS A.4.06 PROPOSED BUILDING SECTIONS - - 13 4 2 1 A7.1 LOCATION KIM RAYMOND ARCHITECTS, INC. 802 EAST COOPER AVE #4 ASPEN, CO 81611 970-925-2252 ARCHITECT 227 E. BLEEKER ABBREVIATIONS MATERIAL LEGEND VICINITY MAP PROJECT TEAMAPPLICABLE CODES PROJECT DATA SHEET INDEX (CONTINUED) SHEET INDEXSYMBOL LEGEND Subdivision: CITY AND TOWNSITE OF ASPEN Block: 120 Lot: F & G PARCEL ID NUMBER: ZONING: LOT SIZE: BLDG USE: OCC. GROUP: CONST. TYPE: CLIMATE ZONE: FIRE SPRINKLERS: LAND USE CATEGORY: TOWNSHIP: RANGE: SECTION: - - - - - - - - - - - - - - - - - - - - - - - - PLT. S.T.D.SLOPE TO DRAIN A A.B. A.F.F. A.F.G. A/C ABC ABS ABV. ACB ACOU. ACT ADD. AG AHU AL. or ALUM. ALT. ANL ASPH. AVG AWG B.M. B.N. B.O. B.O.F. B.U. B/C BD. BLDG BLK. BLKG. BM. BR BRG. BRZ C.A.P. C.D. C.I.P. C.J. C.O. C.T. CAB CAM. CCTV CEM. CER CFM CH CKT. BKR. CL or C.L. CLG. CLKG. CLO. CLR. CMU CNTRD. COL. COMB. CONC. CONST. CONT. CONTR. CU d D.F. D.G. D.S. D/W DBL. DEMO DIA. or Ø DIAG. DIM. DL DN. DR E.A. E.F. E.J. E.N. E.W. EA. EL ELECT. ELEV. EMC EMT ENT EQ. EQUIP. EST. EVAP. EWC EXC EXH. EXIST. or E EXT. F.A. F.C. F.C.O. F.D. F.E. F.N. F.O. F.S. F/G FAB. FACP FDC FDN. FHC FIN. FL FLG. FLUOR. FP FTG. FURN. G.I. GA. GALV. GAR. GFCI GFI GL GLB GM GM GRC GYP. GYP. BD. H.B. H.C. H.M. H/C HDBD. HDW HGT. HOR. HTR HVAC HW HYD. I.C. I.D. I.F. ID IG IMC IMPG INCL. INSUL. INT. J-BOX JCT JT. K-D KD KO L.E.D. L.FT. LAM LAT. LAV LD. LIN. LINO. LT. LTG. LVL M.B. M.H. M.I. M.O. MAR. MAS. MAT'L MAX. MECH. MED. MFG. MFR. MIN. MISC. MOD MTL. MUL N.I.C. N.T.S. NCM NFC NLR. NO. NOM. O.C. O.D. O.H. O.I. O.R. OAI OH OPNG. OPPO. P.C. P.L. P.LAM. P.O.C. PERP. or PH or Ø PL. PLAS. PLUMB. PLYWD. PORC. PERF. PREFAB. PSF PSI PTN. PVC PWR. Q.T. QTY. R R.D.L. R.D.O. R.O. R.O.W. or R/W REF REF. REINF. REQ'D. RET. REV. RM RMV. S.C. S.D. S.O.V. S/L S/S SC SCHED. SECT. SES SH SHT'G. SIM. SPA. SPECS SPKR. SQ. FT. SQ. IN. STC STD. STL. SUSP. SW SYM SYS. T & G T.B. T.M.B. T.O. T.O.B. T.O.C. T.O.F. T.O.J. T.O.M. T.O.S. T.O.W. T.S. T.V. TEL. TH. THD. THK. THRU TLT. TRANS. TYP. UNF. UR V.B. V.I.F. VA VERT. WC WDW WCT WP WT. W/ W/O WD. W.I. YD. AMPERES ANCHOR BOLT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR CONDITIONING AGGREGATE BASE COURSE ACRYLONITRILE-BUTADIENE-STYRENE ABOVE ASBESTOS-CEMENT BOARD ACOUSTIC ACOUSTICAL CEILING TILE ADDITION or ADDENDUM ABOVE GRADE AIR HANDLER UNIT ALUMINUM ALTERNATE ANNEALED ASPHALT AVERAGE AMERICAN WIRE GAUGE ANGLE BENCH MARK BOUNDARY NAILING BOTTOM OF BOTTOM OF FOOTING BUILT UP BACK OF CURB BOARD BUILDING BLOCK BLOCKING BEAM BRASS BEARING BRONZE CONCRETE ASBESTOS PIPE CONSTRUCTION DOCUMENTS CAST IN PLACE CONTROL JOINT CLEAN OUT CERAMIC TILE CABINET CAMBER CLOSED CIRCUIT TELEVISION CEMENT CERAMIC CUBIC FEET PER MINUTE CHANNEL CIRCUIT BREAKER CENTERLINE CEILING CAULKING CLOSET CLEAR CONCRETE MASONRY UNIT CENTERED COLUMN COMBINATION CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR COPPER PENNY DRINKING FOUNTAIN DECOMPOSED GRANITE DOWN SPOUT DISHWASHER DOUBLE DEMOLITION DIAMETER DIAGONAL DIMENSION DEAD LOAD DOWN DOOR EXPANSION ANCHOR EXHAUST FAN EXPANSION JOINT END NAILING EACH WAY EACH ELEVATION "ELECTRIC, ELECTRICAL" ELEVATOR ELECTRICAL METALLIC CONDUIT ELECTRICAL METALLIC TUBING ELECTRICAL NON-METALLIC TUBING EQUAL EQUIPMENT ESTIMATE EVAPORATIVE COOLER ELECTRIC DRINKING COOLER EXCAVATE EXHAUST EXISTING EXTERIOR FIRE ALARM FAN COIL FLOOR CLEAN OUT FLOOR DRAIN FIRE EXTINGUISHER FIELD NAILING FACE OF FLOOR SINK FIBERGLASS FABRICATE FIRE ALARM CONTROL PANEL FIRE DEPARTMENT CONNECTION FOUNDATION FIRE HOSE CABINET FINISH FLOOR FLOORING FLUORESCENT FIRE PROOF FOOTING FURNISH GALVANIZED IRON GAUGE GALVANIZED GARAGE GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT INTERRUPTER GLASS GLUE LAMINATED BEAM GRADE MARK GATE VALVE GALVANIZED RIGID TUBING GYPSUM GYPSUM BOARD HOSE BIBB HOLLOW CORE HOLLOW METAL HANDICAPPED HARDBOARD HARDWARE HEIGHT HORIZONTAL HEATER HEATING, VENTILATING & AIR CONDITIONING HOT WATER HYDRAULIC INTERCOM OUTLET INSIDE DIAMETER INSIDE FACE IDENTIFICATION ISOLATED GROUND INTERMEDIATE METALLIC CONDUIT IMPREGNATED INCLUDE, INCLUSIVE INSULATION INTERIOR JUNCTION BOX JUNCTION JOINT KNOCK DOWN KILN DRIED KNOCK OUT LIGHT EMITTING DIODE LINEAR FEET LAMINATE LATERAL LAVATORY LEAD LINEAR LINOLEUM LIGHT LIGHTING LAMINATED VENEER LUMBER MACHINE BOLT MANHOLE MALLEABLE IRON MASONRY OPENING MARBLE MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM MANUFACTURING MANUFACTURER MINIMUM MISCELLANEOUS MODULAR METAL MULLION NOT IN CONTRACT NOT TO SCALE NON-CORROSIVE METAL NOT FOR CONSTRUCTION NAILER NUMBER NOMINAL ON CENTER OUTSIDE DIAMETER OVER HANG ORNAMENTAL IRON OUTSIDE RADIUS OUTSIDE AIR INTAKE OVER HEAD OPENING OPPOSITE PRECAST CONCRETE PROPERTY LINE PLASTIC LAMINATE POINT OF CONNECTION PERPENDICULAR PHASE PLASTER PLATE PLASTIC PLUMBING PLYWOOD PORCELAIN PERFORATED PREFABRICATED POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PARTITION POLYVINYLCLORIDE POWER QUARRY TILE QUANTITY RADIUS ROOF DRAIN LEADER ROOF DRAIN OVERFLOW ROUGH OPENING RIGHT OF WAY REFRIGERATOR REFERENCE REINFORCED REQUIRED RETURN REVISION ROOM REMOVE SOLID CORE SMOKE DETECTOR SHUT OFF VALVE SKYLIGHT STAINLESS STEEL SELF CLOSING SCHEDULE SECTION SERVICE ENTRANCE SECTION SHEET SHEATHING SIMILAR SPACE SPECIFICATIONS SPEAKER SQUARE FEET SQUARE INCHES SOUND TRANSMISSION CLASS STANDARD STEEL SUSPENDED SWITCH SYMMETRICAL SYSTEM TONGUE AND GROOVE THROUGH BOLT TELEPHONE MOUNTING BOARD TOP OF TOP OF BEAM TOP OF CURB TOP OF FOOTING TOP OF JOIST TOP OF MASONRY TOP OF SLAB TOP OF WALL TUBE STEEL TELEVISION OUTLET TELEPHONE THRESHOLD THREADED THICK THROUGH TOILET TRANSFORMER TYPICAL UNFINISHED URINAL VAPOR BARRIER VERIFY IN FIELD VOLT AMPERE VERTICAL WATER CLOSET WINDOW WAINSCOT WEATHER PROOF WEIGHT WITH WITHOUT WOOD WROUGHT IRON YARD VCT VINYL COMPOSITION TILE JOISTJST. ALL CODES REFERENCED ARE TO BE USED AS AMENDED BY THE STATE OF COLORADO AND LOCAL JURISDICTION. NOTE: CODES BELOW ARE APPLICABLE ONLY IN AREAS. BECAUSE THE SCOPE OF WORK IS LESS THAN 40%, THE PROJECT IS NOT SUBJECT TO UPDATE TO CURRENT CODE -2015 INTERNATIONAL RESIDENTIAL CODE -2015 INTERNATION MECHANICAL CODE -2015 INTERNATIONAL PLUMBING CODE -2015 INTERNATIONAL FUEL & GAS CODE -2015 IECC (INTERNATIONAL ENERGY CONSERVATION CODE) - PITKIN COUNTY EFFICIENT BUILDING CODE -2014 NATIONAL ELECTRICAL CODE FINISH WOOD WOOD STUD BLOCKING STEEL STEEL STUD FRAMED WALL BATT INSULATION PLYWOOD CONCRETE STONE CMU SAND GRAVEL GWB COMPACTED SOIL SPRAY-FOAM INSULATION RIGID INSULATION GRID LINE BREAK LINE MATCH LINE REVISION A-701 ELEVATION MARKER SECTION MARKER DETAIL CUT DETAIL 1 A-501 ELEVATION D01 W01 ROOM NAME 101 INTERIOR ELEVATION MARKER ELEVATION NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER SHEET NUMBER ELEVATION NUMBER SPOT ELEVATION DOOR MARK WINDOW MARK ROOM NAME AND NUMBER 1 A-301 1 A-201 11 MAXIMUM FLOOR AREA: - - SQ FT ALLOWABLE DECK (15% OF MAX FLOOR AREA): - - SQ FT FRONT SETBACK: 10'-0" SIDE SETBACKS: 5'-0" REAR SETBACK: 10'/5''-0" MAXIMUM HEIGHT (PRINCIPAL STRUCTURE) (FT.): 25'-0" 227 E. BLEEKER STREET ASPEN, COLORADO 81611 Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A 1.01 10/26/20 EXISTING: SITE PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 7897 78 9 8 7 8 9 9 F F = 7 8 9 8 . 9 7 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T C O N C W A L K 5' - 0 " SE T B A C K 10'-0" SETBACK 10'-0" SETBACK 5' - 0 " SE T B A C K 1° E. B L E E K E R S T R E E T SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.02 10/26/20 PROPOSED: SITE PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 7897 78 9 8 7 8 9 9 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T E E C C B B A A 2 F F G G 1 3 D D H H 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 6'-8 3/4" 5'-0" 5' - 0 " 13 ' - 1 " 5' - 0 " 5' - 1 7 / 8 " 7' - 1 1 / 4 " 6' - 7 1 / 8 " 6'-10"82'-8 3/4"10'-5 1/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 25'-7"10'-0"47'-1 3/4" 5' - 3 1 / 8 " 26 ' - 8 1 / 4 " 13 ' - 2 1 / 4 " 5'-0"5'-0" FL O W E R S ? E. B L E E K E R S T R E E T 4 PR O P E R T Y L I N E PROPERTY LINE SETBACK LINE SE T B A C K L I N E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.03 10/26/20 PROPOSED: LANDSCAPE PLAN DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T CO N C R E T E PA V E R S GL A S S F L O O R PA T I O E. B L E E K E R S T R E E T SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E PR O P O S E D AD D I T I O N PR O P O S E D AT T A C H E D GA R A G E PR O P O S E D LI N K PR O P O S E D HI S T O R I C BU I L D I N G PE R M E A B L E PA V E R S CONCRETE WALK CE R A M I C TI L E RA I S E D RA I N GA R D E N CO N C R E T E GA R A G E A P R O N AN N U A L FL O W E R GA R D E N AN N U A L F L O W E R G A R D E N ANNUAL FLOWER GARDEN WO O D DE C K I N G ANNUAL FLOWER GARDEN GRAVEL OR MULCH SOD PROPOSED BUILDING WOOD DECK CONCRETE WALKWAY PERMEABLE PAVER CERAMIC TILE GLASS FLOOR LANDSCAPE PLAN KEY N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.04 10/26/20 EXISTING FAR CALCULATIONS DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 RG F 1,538 sq ft SE T B A C K L I N E PR O P E R T Y L I N E SETBACK LINE PROPERTY LINE SCALE: 1/8" = 1'-0"1 EXISTING MAIN LEVEL FAR Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.05 10/26/20 PROPOSED FAR CALCULATIONS DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 W/DW/D 1 2 4 3 5 6 GLASS FLOOR ABOVE 2,635 sq ft PROPERTY LINE PR O P E R T Y L I N E SE T B A C K L I N E PR O P E R T Y L I N E PORCH: 132 sq ft PATIO:101 sq ft FF: 100'-2 1/4" = 7899.97'(100'-0" = 7898.78') GARAGE FLOOR AREA 350 SQ FT TALL CABINET (BOOT WARMERS) BENCH W/ CUBBIES ABOVETALL CABINET (BOOT WARMERS) TRASH) SK I S T O R A G E R A C K BI K E S T O R A G E DN ST O R A G E ST O R A G E HA N G I N G WET BAR WINE CABINET 1,461 sq ft 364 sq ft= 57.0 sq ft SE T B A C K L I N E PR O P E R T Y L I N E SETBACK LINE PROPERTY LINE PARKING SPACE UP DN 442 sq ft 182 sq ft SE T B A C K L I N E PR O P E R T Y L I N E 308 sq ft 647 sq ft 11 sq ft 3 sq ft 392 sq ft970 sq ft 2 sq ft 355 sq ft 1 sq ft 2.3.1. 5.4.6. 14 sq ft 26 sq ft 27 sq ft23 sq ft SCALE: 1/8" = 1'-0"0 PROPOSED LOWER LEVEL FAR SCALE: 1/8" = 1'-0"1 PROPOSED MAIN LEVEL FAR SCALE: 1/8" = 1'-0"2 PROPOSED UPPER LEVEL FAR SCALE: 1/8" = 1'-0"0 PROPOSED LOWER LEVEL FAR - ELEVATIONS N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.00 10/26/20 EXISTING: MAIN LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 7897 78 9 8 7 8 9 9 F F = 7 8 9 8 . 9 7 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T C O N C W A L K E. 5 E. 5 E E C C B B A A 2 1 3 D D RG F 5' - 7 7 / 8 " 11'-7 1/4" 5' - 0 " SE T B A C K 10'-0" SETBACK 10'-0" SETBACK 5' - 0 " SE T B A C K 1° BE D R O O M KI T C H E N BE D R O O M BA T H PA N T R Y ST O R A G E HA L L EN T R Y ST O R A G E LI V I N G R O O M DI N I N G R O O M E. B L E E K E R S T R E E T 4 SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.01 10/26/20 EXISTING: ROOF PLAN DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T C O N C W A L K E. 5 E. 5 E E C C B B A A 2 1 3 D D E. B L E E K E R S T R E E T AL L E Y 4 SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.02 10/26/20 PROPOSED: LOWER LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 E E C C B B A A 2 F F G G 2. 5 1. 5 1 1 3. 5 3 D D 0 H H W/ D W/ D 1'-10"3'-2" 82'-8 3/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 10'-5 1/4" 6' - 7 1 / 8 " 31 ' - 5 1 / 4 " 7' - 1 1 / 4 " 10 ' - 0 1 / 2 " 14 ' - 3 " 7' - 1 3 / 4 " 6'-10" LA U N D R Y W. I . C . W. I . C . BA T H 3 BA T H 2 GL A S S F L O O R AB O V E GY M FA M I L Y R O O M BE D R O O M 3 BE D R O O M 2 BE D R O O M 1 BA T H 1 W. I . C . li n e n li n e n TV / FP? 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 PR O P E R T Y L I N E PROPERTY LINE SETBACK LINE PROPERTY LINE ME C H A N I C A L A N D ST O R A G E 4 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.03 10/26/20 PROPOSED: MAIN LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 CO N C R E T E S I D E W A L K E E C C B B A A 2 F F G G 2. 5 1. 5 1 1 3. 5 3 D D 0 H H 6'-10"82'-8 3/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"3'-5 1/4"8 3/4" 10'-5 1/4" 6' - 7 1 / 8 " 31 ' - 5 1 / 4 " 7' - 1 1 / 4 " 10 ' - 0 1 / 2 " 14 ' - 3 " 7' - 1 3 / 4 " 25'-7"10'-0"47'-1 3/4" 5' - 3 1 / 8 " 26 ' - 8 1 / 4 " 13 ' - 4 " FF : 1 0 0 ' - 2 1 / 4 " = 7 8 9 9 . 9 7 ' (1 0 0 ' - 0 " = 7 8 9 8 . 7 8 ' ) 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 GA R A G E PO R C H DI N I N G RO O M GA R A G E F L O O R A R E A 3 5 0 S Q F T BI G O P E N FI R E P L A C E AR T I S T I C FE A T U R E KI T C H E N LI V I N G R O O M PA T I O MU D RO O M TO MA S T E R TO LO W E R WE T BA R WI N E CA B I N E T PA N T R Y TA L L CA B I N E T (B O O T W A R M E R S ) BE N C H W / CU B B I E S A B O V E TA L L CA B I N E T (B O O T W A R M E R S ) TR A S H ) SKI STORAGE RACK BIKE STORAGE DN STORAGE STORAGE HANGING WE T BA R WI N E CA B I N E T 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 4 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E PA R K I N G S P A C E UP N N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.04 10/26/20 PROPOSED: UPPER LEVEL PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 E E C C B B A A 2 F F G G 2. 5 1. 5 1 1 3. 5 3 D D 0 H H 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 3'-3" 5' - 3 1 / 4 " 26 ' - 8 1 / 4 " 13 ' - 2 1 / 4 " 8' - 2 1 / 4 " 5' - 0 " 6'-10"82'-8 3/4"10'-5 1/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 6' - 7 1 / 4 " 31 ' - 5 1 / 4 " 7' - 1 1 / 4 " 10 ' - 0 1 / 2 " 14 ' - 3 " 7' - 1 3 / 4 " 6'-10"25'-7"10'-0"47'-1 3/4"10'-5 1/4" MA S T E R BE D R O O M W. I . C . DE C K DN MA S T E R B A T H 20 1 20 2 20 3 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 4 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 SETBACK LINE PROPERTY LINE N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.2.05 10/26/20 PROPOSED: ROOF PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 CO N C R E T E S I D E W A L K E E C C B B A A 2 F F G G 2. 5 1. 5 1 1 3. 5 3 D D 0 H H 2 A 3 . 1 2 A 3.1 2 A 3.1 2 A 3 . 1 6'-8 3/4" 5'-0" 5' - 0 " 13 ' - 1 " 5' - 0 " 5' - 1 7 / 8 " 7' - 1 1 / 4 " 6' - 7 1 / 8 " 6'-10"82'-8 3/4"10'-5 1/4" 3'-7"22'-0"10'-0"14'-1 3/4"14'-5 1/4"14'-4 3/4"4'-2" 25'-7"10'-0"47'-1 3/4" 5' - 3 1 / 8 " 26 ' - 8 1 / 4 " 13 ' - 2 1 / 4 " 5'-0"5'-0" FL O W E R S ? 1 A 5 . 1 1 A 5 . 1 2 A 5 . 1 2 A 5 . 1 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 1 A 5 . 2 4 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 1 A 5 . 3 PR O P E R T Y L I N E PROPERTY LINE SETBACK LINE SE T B A C K L I N E N SCALE: 1/4" = 1'-0" Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.01 10/26/20 EXISTING ELEVATIONS: NORTH & EAST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 243 1 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" E.5 E C B AD T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"1 EXISTING NORTH ELEVATION SCALE: 1/4" = 1'-0"2 EXISTING EAST ELEVATION Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.02 10/26/20 EXISTING ELEVATIONS: SOUTH & WEST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 E.5ABCED T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 21 3 4 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"2 EXISTING WEST ELEVATION SCALE: 1/4" = 1'-0"1 EXISTING SOUTH ELEVATION Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.03 10/26/20 PROPOSED ELEVATIONS: NORTH & EAST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 23.5 2.5 1.543 11 0 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" FG E C B ADH T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. UPPER LEVEL PLY 110'-0" TOP PLATE @ GABLE ROOFS 119'-2 1/4" SCALE: 1/4" = 1'-0"1 PROPOSED NORTH ELEVATION SCALE: 1/4" = 1'-0"2 PROPOSED EAST ELEVATION Scale: AS NOTED ISSUE HPC SET #1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.3.03 10/26/20 PROPOSED ELEVATIONS: SOUTH & WEST DATE KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 10/26/20 A B C ED F G H T.O. MAIN LEVEL PLY 100'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. LOWER LEVEL SLAB 86'-6" T.O. UPPER LEVEL PLY 110'-0" T.O. UPPER LEVEL PLY 110'-0" TOP PLATE @ GABLE ROOFS 119'-2 1/4" 1.5 2.521 3.513 40 T.O. LOWER LEVEL SLAB 88'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. LOWER LEVEL SLAB 88'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" TOP PLATE @ GABLE ROOFS 119'-2 1/4" TOP PLATE @ GABLE ROOFS 119'-2 1/4" SCALE: 1/4" = 1'-0"2 PROPOSED WEST ELEVATION SCALE: 1/4" = 1'-0"1 PROPOSED SOUTH ELEVATION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.01 10/26/20 EXISTING BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 24 13 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 7898.00' FF:7898.97' SCALE: 1/4" = 1'-0"2 EXISTING BUILDING SECTION SCALE: 1/4" = 1'-0"1 EXISTING BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.02 10/26/20 EXISTING BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" 2 413 T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"3 EXISTING BUILDING SECTION SCALE: 1/4" = 1'-0"4 EXISTING BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.03 10/26/20 EXISTING BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 E.5 BCE AD T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" E.5ABCED T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" SCALE: 1/4" = 1'-0"5 EXISTING BUILDING SECTION SCALE: 1/4" = 1'-0"6 EXISTING BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.04 10/26/20 PROPOSED BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 T.O. BASEMENT SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-06" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" 24 133.5 2.5 1.5 1 0 T.O. BASEMENT SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" T.O. BASEMENT SLAB 86'-6" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" 7898.00' FF:7898.97' SCALE: 1/4" = 1'-0"2 PROPOSED BUILDING SECTION SCALE: 1/4" = 1'-0"1 PROPOSED BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.05 10/26/20 PROPOSED BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 2 413 T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" 1.5 2 2.5 41133.50 T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 109'-5" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" TOP PLATE @ GABLE ROOFS 119'-2 1/4" TOP PLATE @ GABLE ROOFS 119'-2 1/4" SCALE: 1/4" = 1'-0"3 PROPOSED BUILDING SECTION SCALE: 1/4" = 1'-0"4 PROPOSED BUILDING SECTION Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.4.06 10/26/20 PROPOSED BUILDING SECTIONS DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 BCEFG ADH T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" TOP PLATE @ GABLE ROOFS 119'-2 1/4" T.O. UPPER LEVEL PLY 110'-0" A B C E F GD H T.O. MAIN LEVEL PLY 100'-0" T.O. MAIN LEVEL PLY 100'-0" T.O. UPPER LEVEL PLY 110'-0" T.O. BASEMENT SLAB 86'-6" T.O. BASEMENT SLAB 86'-6" TOP PLATE @ GABLE ROOFS 119'-2 1/4" SCALE: 1/4" = 1'-0"5 PROPOSED BUILDING SECTION SCALE: 1/4" = 1'-0"6 PROPOSED BUILDING SECTION 227 E. Bleeker St. 418 E. Cooper Ave. Suite 201-Aspen, CO 81611 www.kimraymondarchitects.com OCTOBER 26, 2020 KIM RAYMOND ARCHITECTURE+INTERIORS 227 E. BLEEKER ST. HPC:SUPPLEMENTAL VISUAL REPRESENTATION www.kimraymondarchitects.com HISTORIC REFERENCE: WEST SIDE VIEW 227 E. Bleeker St. 209 E. BLEEKER 227 E. BLEEKER www.kimraymondarchitects.com EXISTING: FRONT VIEW 227 E. Bleeker St. www.kimraymondarchitects.com EXISTING: BACK VIEW 227 E. Bleeker St. www.kimraymondarchitects.com PROPOSED VIEW 1: AERIAL 227 E. Bleeker St. www.kimraymondarchitects.com PROPOSED VIEW 2: FRONT (NORTH ELEVATION) 227 E. Bleeker St. www.kimraymondarchitects.com PROPOSED VIEW 3: BACK (SOUTH ELEVATION) 227 E. Bleeker St. www.kimraymondarchitects.com PROPOSED VIEW 4: WEST 227 E. Bleeker St. www.kimraymondarchitects.com PROPOSED VIEW 5: EAST 227 E. Bleeker St. P.O. Box 3901 Eagle, Colorado 81631 YARNELL CONSULTING & CIVIL DESIGN, LLC (970) 323-7008  11/19/2020 229 Midland Ave. Basalt, Colorado 81621 227 E. Bleeker Street, Aspen, Colorado Page 1 of 2 Patricia Weber Kim Raymond Architects 418 East Cooper Avenue, Suite 201 Aspen, Colorado 81611 Patricia@KRAI.us Subject: 227 E. Bleeker Street, Aspen, Colorado Historic Preservation Committee Stormwater Management Review Patricia: I understand Aspen Starwood, LLC is pursuing the restoration of the historic miner’s cabin located on the subject property. Due to it being designated a historic monument within the city, work associated with the cabin requires review and approval by the Aspen Historic Preservation Committee (HPC). HPC requested that stormwater design be considered at Conceptual review. The intent of this letter is to accompany updates to the architectural site plan to fulfill said requirement. Based on the topographic data from Aspen Survey, the existing site is low relative to the alley, East Bleeker Street and both the easterly adjacent property. To improve the drainage condition and meet current engineering code, it is desired to raise the floor of the existing structure and fill the site to provide adequate positive drainage into East Bleeker Street and the alley. Without this approach, runoff from the rights-of-way will flow onto the property and flood the home in a future large storm event. Redevelopment of the subject property to the extent desired falls under the requirements of a “Major Redevelopment” as defined within Chapter 1 of the City of Aspen Urban Runoff Management Plan (URMP). The primary component of this for the subject property will be providing the requisite water quality capture volume. While the architectural site plan currently shows incorporation of a rain garden into the project, it is unlikely to be viable to route the drainage from all the impervious areas on-site to this feature. Alternatively, it will likely just be able to capture runoff from roofs that are immediately adjacent and whose downspouts can drop to the rain garden. HPC regulations prohibit the construction of rain gardens in front of the historic building which further limits opportunities for on-grade water quality management. While deemed a “last resort” option, it is likely the project will need to incorporate a below-grade storage and infiltration system similar to StormTech. This will be further coordinated with the city’s Engineering Department. Per the URMP, no on-site detention or off-site drainage analysis will be required for this project since it is located in the Aspen Mountain drainage basin. As such, the below-grade system will be designed for small storm events with means of overflow into the rights-of-way for large storms. Please let me know if you have any further questions that I can answer regarding the anticipated stormwater management strategies for the redevelopment of the subject property. P.O. Box 3901 Eagle, Colorado 81631 YARNELL CONSULTING & CIVIL DESIGN, LLC (970) 323-7008  11/19/2020 229 Midland Ave. Basalt, Colorado 81621 227 E. Bleeker Street, Aspen, Colorado Page 2 of 2 Sincerely, Justin J. Yarnell, PE Colorado PE Number 47241 Scale: AS NOTED ISSUE HPC SET #1 22 7 E . B L E E K E R 22 7 E . B L E E K E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 1" ACTUAL IF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICATED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WITHOUT WRITTEN PERMISSION. WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT THE SITE . ANY DIMENSIONAL DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. A.1.06 11/23/20 PROPOSED: SCHEMATIC DRAINAGE PLAN DATE 10/26/20 KI M R A Y M O N D A R C H I T E C T S , I N C . 41 8 E . H Y M A N A V E N U E , S U I T E 2 0 1 w w w . k i m r a y m o n d a r c h i t e c t s . c o m 9 7 0 - 9 2 5 - 2 2 5 2 CO N C R E T E S I D E W A L K ED G E O F P A V E M E N T F CO N C R E T E PA V E R S GL A S S F L O O R PA T I O BE L O W - G R A D E S T O R M W A T E R AN D I N F I L T R A T I O N S Y S T E M (S T O R M T E C H O R S I M I L A R ) . SI Z E I S A P P R O X I M A T E A N D W I L L UL T I M A T E L Y B E B A S E D U P O N T H E RE Q U I R E D Q U A L I T Y C A P T U R E VO L U M E F O R T H E S I T E . ST O R M P I P E W I T H I N T E R M I T T E N T IN L E T S T O C O L L E C T D R A I N A G E FR O M T H E S I D E Y A R D . D O W N S P O U T S AL O N G T H E S I D E O F T H E H O M E WI L L B E R O U T E D T O T H I S P I P E . E. B L E E K E R S T R E E T ST O R M P I P E W I T H I N T E R M I T T E N T IN L E T S T O C O L L E C T D R A I N A G E FR O M T H E S I D E Y A R D . D O W N S P O U T S AL O N G T H E S I D E O F T H E H O M E WI L L B E R O U T E D T O T H I S P I P E . TR E N C H D R A I N T O IN T E R C P E T R U N O F F FR O M D R I V E W A Y . SETBACK LINE PROPERTY LINE SE T B A C K L I N E PR O P E R T Y L I N E PR O P O S E D AD D I T I O N PR O P O S E D AT T A C H E D GA R A G E PR O P O S E D LI N K PR O P O S E D HI S T O R I C BU I L D I N G PE R M E A B L E PA V E R S CONCRETE WALK CE R A M I C TI L E RA I S E D RA I N GA R D E N CO N C R E T E GA R A G E A P R O N AN N U A L FL O W E R GA R D E N AN N U A L F L O W E R G A R D E N ANNUAL FLOWER GARDEN WO O D DE C K I N G STORMWATER STORAGE SCHEMATIC DRAINAGE PLAN KEY PERFORATED STORM PIPE TRENCH DRAIN 227 E. BLEEKER STREET LEGAL DESCRIPTION: Subdivision: EAST BLEEKER HISTORIC LANDMARK Block: 73 Lot 2, East Bleeker Historic Lot Split. VICINITY MAP CITY OF ASPEN VICINITY MAP I "=400' r l\II14\11r /1L I\L/11\ JL I Ufi\if\ PLAT BK 78 PG 5 LOT 2 EAST BLEEKER HISTORIC LOT SPLIT CITY OF ASPEN GPS MONUMENT #8 PI TKIN COUNTY, COL ORAD O ❑ 5 10 20 1" = 10' NOTES 1) LEGAL DESCRIPTION: LOT 2, EAST BLEEKER HISTORIC LOT SPLIT, ACCORDING TO THE FINAL PLAT THEREOF W FILED ON RECORD IN PLAT BOOK 78 AT PAGE 5 AS RECEPTION NO. 521939 IN THE \ COUNTY OF PITKIN, STATE OF COLORADO. 2) BASIS OF BEARING: A BEARING OF N14°50'49"E BETWEEN A FOUND #5 REBAR AND 1%" YPC LS# 29030 AT THE S.W. PROPERTY CORNER AND A FOUND #5 REBAR AND 1%" YPC LS# 29030 AT THE N.W. PROPERTY CORNER. \ BEARING BASED ON EAST BLEEKER HISTORIC LOT SPLIT PLAT. 3) THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH BY THIS SURVEYOR. TITLE INFORMATION RELIED UPON FOR THE PREPARATION OF THIS SURVEY FURNISHED BY ATTONEYS TITLE INSURANCE AGENCY OF ASPEN, COMMITMENT NO. 20004528, DATED 08/20/2020. TREE TABLE TREE ID# TREE TYPE TRUNK DIAMETER DRIP LINE RADIUS 1 DECIDU❑US 6" 8' 2 DECIDU❑US 9" 8' 3 DECIDU❑US 6" 5' 4 DECIDU❑US 6" 9' 5 EVERGREEN 12" 10' 6 DECIDU❑US 10" 10' 7 DECIDU❑US 10" 10' 8 DECIDU❑US 11" 14' 9 DECIDU❑US 10" 10' 10 DECIDU❑US 11" 12' 4) UNIT OF MEASUREMENT FOR THIS SURVEY IS THE U.S. SURVEY FOOT. 5) ELEVATIONS BASED UPON CITY OF ASPEN GPS MONUMENT #6 (7893.61' NAVD 88 DATUM). BENCHMARK= 7896.76' AT N.W. PROPERTY CORNER. CONTOUR INTERVAL IS 1(ONE) FOOT. 6) ACCORDING TO FIRM MAP 0897CO354E, DATED AUGUST 15, 2019, SAID LOT IS CONSIDERED TO BE IN ZONE X AND OUTSIDE THE 500 YEAR FLOOD PLAIN. 7) CITY OF ASPEN BUILDING RESTRICTIONS: SETBACK RESTRICTIONS: R-6 ZONE DISTRICT REGULATIONS. SIDE YARDS:5.0' REAR YARD:10.0' RES. 5.0' ACCESSORY FRONT YARD:10.0' RES. 15.0' ACCESSORY 8) DISTANCE TO NEAREST INTERSECTING STREET: 125.0t 9) NO NATURAL HAZARDS WERE FOUND TO AFFECT SAID PARCEL ACCORDING TO MAPS PROVIDED BY THE CITY OF ASPEN'S ENGINEERING DEPARTMENT. 10) POSTED ADDRESS IS 227 E. BLEEKER ST, ASPEN, CO 81611. LEGEND O INDICATES FOUND MONUMENT AS DESCRIBED. INDICATES CITY OF ASPEN GPS MONUMENT YPC 1 %" YELLOW PLASTIC CAP ON #5 REBAR ALC 2" ALUMINUM CAP ON #5 REBAR EM ELECTRIC METER QT TELEPHONE RISER GM GAS METER m WATER VALVE WW WINDOW WELL ® ELECTRIC TRANSFORMER RO ROOF OVERHANG 3 IS Ei FENCE LINE G BURIED GAS LINE C BURIED COMMUNICATION LINE E BURIED ELECTRICAL LINE W BURIED WATER LINE S BURIED SEWER LINE DECIDUOUS TREE EVERGREEN TREE SURVEYOR'S CERTIFICATE I, MICHAEL P. LAFFERTY, HEREBY CERTIFY THAT THIS MAP ACCURATELY DEPICTS AN IMPROVEMENT SURVEY PLAT PERFORMED UNDER MY SUPERVISION ON 10/2020 OF THE ABOVE DESCRIBED PARCEL OF LAND. THE LOCATION AND DIMENSIONS OF ALL IMPROVEMENTS, EASEMENTS, RIGHTS -OF -WAY IN EVIDENCE OR KNOWN TO ME AND ENCROACHMENTS BY OR ON THESE PREMISES ARE ACCURATELY SHOWN. ERROR OF CLOSURE IS LESS THAN 1 /15,000. MICHAEL P. LAFFERTY PLS. # 37972