Loading...
HomeMy WebLinkAboutRE_ HPC Referral_ 121 W. Bleeker_BuildingFrom:Bonnie Muhigirwa To:Sarah Yoon Cc:Denis Murray; Nick Thompson Subject:RE: HPC Referral: 121 W. Bleeker Date:Friday, March 12, 2021 2:59:46 PM Attachments:image003.png image004.png image005.png image002.png image007.jpg image008.jpg image009.jpg image010.jpg image011.png Hi Sarah, Building Comments: Fire sprinklers will be required because the fire area exceeds 5,000 sf. Exterior stair to the roof deck does not meet fire separation distance requirements per 2015 IRC Table 302.1(2). Projections need to be at least 2 feet from the property line and have a 1 hour fire-resistance rating if less than 3 feet from the property line. Window well can not be located in a patio without guard protection per city policy https://www.cityofaspen.com/DocumentCenter/View/6195/Emergency-Escape-and-Rescue- Window-Wells The guest mater suite located in the historic resource needs a compliant emergency escape and rescue opening per R310.2.1 Hot tub at the roof deck will need to be located at least 18” from the deck edge or the guard height will need to extend 18” above the top of the hot tub per city policy https://www.cityofaspen.com/DocumentCenter/View/6202/Hot-Tub-and-Spa-Safety-Railings Snow fencing is required on the historic roof where snow sheds into the window well on the east side. Thanks, Bonnie Muhigirwa Plans Examiner / Building Inspector III Community Development 130 S Galena St. Aspen, CO 81611 p: 970.429.2787 c: 970.309.5119 www.cityofaspen.com