Loading...
HomeMy WebLinkAbout227 E Bleeker Zoning Comments - 11.17.2020 MEMORANDUM TO: Sarah Yoon, Historic Preservation Planner FROM: Sophie Varga, Zoning Enforcement Officer DATE: 11/17/2020 RE: 227 E Bleeker Referral Comments Floor area calculations: 1. Allowed deck exemption: the deck exemption is calculated off of the prescribed floor area by the specific approval (1,800 SF); the Floor area bonus is not included. The deck exemption is 270 SF. a. Plan Sheet: A.1.05 b. Code Section: 26.575.020.D.4(b) 2. Front porches: if the front porches are more than 30” above finished grade they are attributed to floor area as deck. Both front porches need to be included in floor area calculations. a. Plan Sheet: A.1.05 b. Code Section: 26.575.020.D.5 3. Subgrade wall calculations: The percentage of exposed wall area should be rounded up to 3.5 (from 3.46). It is preferable to be consistent with the number of decimal places; two are used in all other calculations. Provide sections that clearly depict the interior wall being projected outward, especially for Walls 2 and 6. If finished grade and natural grade are the same, note this. a. Plan Sheet: A.1.05 b. Code Section: 26.575.020.D.8 Setback Variations: please be sure to dimension all projections into the setback. A variation needs to be requested for the rear yard setback for all three levels (this portion of the building is not used solely as a garage – there is a deck above it). A variation request should also be made to legalize the existing overhang into the front yard setback. This memorandum summarizes major items. A variety of other requirements will be necessary for building permit submittal and zoning review.