HomeMy WebLinkAbout2021.1.5_303 PARK AVE_PERMIT SETCIVIL ENGINEER:
-
CONTACT:
-
-
COL.
C.O.
CEILING HEIGHT A.F.F.+13'-11"
303 PARK AVE
273718138001
NO
R-6
2,596.78 GROSS SF AREA (INCL. 283 GARAGE) / 582.92 GROSS SF
DECK (NO CHANGE TO FAR OR FOOTPRINT)
Residential
Side - 30' total, 10' min each / Front & Rear - 10'
ZONING:
F.A.R.
PERMITTED USE:
SETBACKS:
Tread
Terrazzo
Thick
Tempered
TEL.
T.C.
T.B.
T.
THK.
T.M.E.
T.O.C.
T.&G.
TER.
TEMP.
To Match Existing
Top of Concrete
Towel Bar
Top of Curb
Telephone
Tongue & Groove
Typical
Varies
UnfinishedUNF.
V.C.T.
VAR.
U.O.N.
UNEXC.
U.B.C.
T.O. PLY
T.O.W.
TYP.
Veneer
Vertical
Vestibule
Volume
Wood
West
With
V.I.F.
W.C.
WD.
W.H.
W.
W/
V.G.D.F.
VOL.
VERT.
VEST.
VEN.
Wall Covering
Water Heater
Vertical Grain Douglas Fir
Verify in Field
Vinyl Composition Tile
Top of Plywood
Top of Wall
Uniform Building Code
Unexcavated
Unless Otherwise Noted
Top of PlateT.O.P.
Wainscot
Weight
W.P.
WW.
WR.
WT.
W.S.P.
W.P.M.
WSCT.
Welded Wire
Work Point or
Waterproofing
Waterproof Membrane
Wet Standpipe
Water Resistant
WithoutW/O
REQ.
RESIL.
REINF.
REG.
REV.
RWD.
REMOV.
R.O.
RM.
RET.
Rough Opening
Redwood
Required
Removable
Room
Resilient
Retaining
Reinforced
Register
Mounted
Mullion
Nominal
North
Number
New
Not to Scale
Miscellaneous
Not in Contract
S.C.D.
S.D.
S.
S.A.F.F
SEP.
SHT.
S.H.
SECT.
S.E.D.
SCHED.
Separation
Sprinkler Head
Sheet
See Civil Drawings
Soap Dispenser/Dish
See Electrical Drawings
Storm Drain,
Schedule
Section
Self-Adhesive Flexible Flashing
South
S.G.D.
S.L.D.
SHTG.
S.C.D.
SL.
SIM.
S.P.D.
SPEC.
S.M.D.
S.S.
SQ.
S.LT.D.
Stainless Steel
Square
See Lighting Drawings
See Garage Drawings
See Plumbing Drawings
See Civil Drawings
Sheathing
Sliding
Similar
Opposite
Opening
On Center
Overall
Plaster
Plywood
Perimeter
Plate
Plastic Laminate
Outside Diameter (Dim.)
Point
Paint
Quarry Tile
Partition
Painted
Paper Towel Receptacle
Per Square Inch
Pressure Treated
Post Tensioned
Paper Towel Dispenser
Panel
MUL.
MISC.
MTD.
NOM.
N.T.S.
N.I.C.
N.
(N)
Hardware
Hardwood
Hanger
Height
Horizontal
Handrail
Hour
Hot Water Heater
Hollow Metal
HGT.
HDW.
HDWD.
HGR.
H.W.H.
HORIZ.
HR.
H.R.
H.M.
Floor Drain
Fire Extinguisher
Cabinet
Flat Bar
Fixture
Floor
Srew
Finish
Flat Head Wood Screw
Flat Head Machine
OPP.
O.A.
O.C.
O.D.
PLAS.
PL.
Insulation
Interior
Inch
Kitchen
Joist
Joint
Janitor
Junction Box
Intermediate
P.S.I.
PNT.
PT.
P.T.
P.T.R.
P.T.D.
PTN.
Q.T.
PTD.
Laminate
Lavatory
Pound
Linear
Light
Maintain
Material
Maximum
Machine
PNL.
INTER.
IN.
INSUL.
INT.
KIT.
JST.
JB
JT.
JAN.
Fluorescent
Face of Finish
Face of Plywood
Face of Stud
Footing
Furring
Future
Frame
Foot or Feet
Fireproof
Face of Concrete
LB.
LIN.
LT.
LAM.
LAV.
MAINT.
MAT.
MAX.
MACH.
General
Gauge
Gas Outlet
Galvanized
Ground
Grade
Glass
Interrupt
Ground Fault
Galvanized Sheet
Garbage Disposal
Flashing Inside DiameterI.D.
ABBREVIATIONS
P.LAM.
PLYWD.
PERIM.
OPNG.
NO. or #
STOR.
STRL.
STD.
STL.
S.V.
SYS.
SYM.
S.W.
System
Steel
Structural
Sheet Vinyl
Shear Wall
Symmetrical
Storage
StandardReturn Air
Recessed
Radius
Riser
Reference
Reflected
Refrigerator
REC.
RAD.
R.A.
R.
REFR.
REFL.
REF.
Overlay
Mechanical
Membrane
Minimum
Metal
Machine Bolt
Medicine Cabinet
Medium Density
Manufacturer
M.D.O.
MEMB.
MECH.
M.B.
M.C.
MIN.
MTL.
MFR.
Gypsum
Handicapped
Hose Bibb
Hollow Core or
Header
Head
Hardboard
Metal
S.S.D. See Structural Drawing
Specification or Special
See Landscape Drawings
See Mechanical Drawings
Revision/Revised/Reversed
F.E.
F.B.
F.D.
FIXT.
FLR.
F.H.W.S.
FIN.
F.H.M.S.
CONSTR.
CONN.
COND.
CONC.
CTR.
C.W.
C.T.
CONTR.
CLOS.
CONT.
Center
Cold Water
Contractor
Closet
Ceramic Tile
Condition
Connection
Construction
Continuous
Concrete
F.O. Ply
F.O.S.
FLUOR.
F.O.C.
F.O.F.
FURR.
FUT.
FTG.
FR.
FT.
F.P.R.F.
GALV.
G.D.
GEN.
G.
GA.
GND.
G.S.M.
GR.
GL.
G.F.I.
DIA.
DIM.
DBL.
DET.
D.F.
DWG.
DWR.
D.W.
DN.
DR.
DISP.
E.J.
EA.
(E)
E.I.F.S.
E.O.S.
ENCL.
E.P.B.
ELEC.
EMER.
EL.
Dishwasher
Edge of Slab
Electrical Panel Board
Enclosure
Exterior Insulation &
Elevation
Electrical
Emergency
Existing
Finish System
Expansion Joint
Each
Drawing
Drawer
Drinking Fountain
Dispenser
Down
Door
Double
Diameter
Dimension
Detail
FLASH.
At@
&
<
A.C.
#
0
ACOUS.
ALUM.
ALT.
ADJ.
AGGR.
ADJAC.
BITUM.
BD.
ARCH.
ASPH.
APPROX.
BM.
B.O.
BOT
BLKG.
BLK.
C.B.
CEM.
CER.
B.P.
BTWN.
BLDG.
A.D.
Catch Basin
Cement
Ceramic
Beam
Bottom of
Building Paper
Between
Bottom
Building
Blocking
Bituminous
Board
Block
Diameter or Round
Air Conditioning or
Asphaltic Concrete
Aluminum
Approximate
Architectural
Asphalt
Alternate
Acoustical
Area Drain
Adjustable
Aggregate
Adjacent
Pound or Number
Angle
And
H.B.
H.C.
GYP.
HDR.
HDBD.
HD.
EXP.
EXT.
EXIST.
EQUIP.
F.A.U.
F.A.
Forced Air Unit
Fire Alarm
Equipment
Existing
Expansion
Exterior
CLKG.
C.M.U.
CLR.
CLG.
CNTR.
Column
Concrete Masonry
Caulking
Clean-Out
Counter
Unit
Clear
Ceiling
C.J. Control Joint EqualEQ.
PROJECT DIRECTORYVICINITY PLAN
STRUCTURAL ENGINEER:
LANDSCAPE DESIGN:
SHEET NUMBER
INTERIOR ELEVATION NUMBERS
SYMBOLS
3
A6.1
1
A4.3
DOOR SYMBOL14
1A
A
3
A6.1
DETAIL NUMBER
SHEET NUMBER
WINDOW SYMBOL
PARTITION TYPE
SHEET NUMBER
BUILDING SECTION NUMBER
SHEET NUMBER
ENLARGED DETAIL NUMBER
HOSE BIBB
REVISION
COLOR
FINISH MATERIAL
HB
JB
XX
X
1
(N)/(E) CONSTRUCTION
JUNCTION BOX
Aspen, Colorado
303 PARK AVE
GENERAL NOTES
PROJECT STATISTICS
TYPE:
OCCUPANCY:
OVERALL PROJECT HEIGHT AND AREA:
PROJECT SUMMARY:
Type VB - Non-rated
Type R-3
Maximum Height 25'
INTERIOR REMODEL OF 3 LEVELS. NO CHANGE TO FAR
UPDATING LAYOUT, REPLACING ALL FIXTURES / APPLIANCES.
REPLACEMENT OF STAIR RAILING AND TREADS.
REPLACEMENT OF CERTAIN EXISTING WINDOWS AND DOORS.
-
-
CONTACT:
-
A5.2
1
2
3
4
FOR ALL DRAWINGS EXCEPT
DETAILS
DIMENSIONING KEY
TICK LEADER DENOTES DIMENSION
TO FRAMING
DOT LEADER DENOTES DIMENSION
TO GRIDLINE/<
2'-2"3'-6"
ARROW LEADER DENOTES
DIMENSION TO FINISH
3'-5"
PERMIT SET
JANUARY 5, 2021
SITE
303 PARK AVE
ASPEN, COLORADO
The work included under this contract consists of all labor, materials, transportation, tools and equipment necessary for the
construction of the project leaving all work ready for use.
The construction documents are the property of Thunderbowl Architects Inc and its Consultants and are to be used as
instruments of service for construction of this project only. Use for any other purpose, without authorization, is not
allowed.
The plans indicate the general extent of new construction necessary for the work, but are not intended to be all-inclusive.
All demolition and all new work necessary to allow for a finished job in accordance with the intention of the drawing is
included regardless of whether shown on the drawings or mentioned in the notes.
Any errors, omissions or conflicts found in the various parts of the construction documents shall be brought to the attention
of the Architect and the Owner for clarification before proceeding with the work.
The General Contractor shall maintain a current and complete set of the construction documents on the job site during all
phases of construction for use of all the trades and shall provide all the subcontractors with current and complete
construction documents as required including specifications and architectural supplementary instructions.
The General Contractor shall verify and assume responsibility for all dimensions and site conditions. The General
Contractor shall inspect the existing premises and take note of existing conditions prior to submitting prices. No claim shall
be allowed for difficulties encountered which could have reasonably been inferred from such an examination.
Written dimensions take precedence. Do not scale drawings.
See SYMBOLS area of this sheet for dimension standards.
All dimensions noted "verify" and "V.I.F." are to be checked by Contractor prior to construction. Immediately report any
variances to the Architect for resolution, then coordinate resolution w/ all work of all trades.
Coordinate all work with existing conditions, including but not limited to: irrigation pipes, electrical conduit, water lines, gas
lines, drainage lines, etc. Notify Architect immediately of any conflicts.
Provide adequate temporary support as necessary to assure the structural value or integrity of the building.
Protect all existing building and site conditions to remain, including walls, cabinets, finishes, trees and shrubs, paving, etc.
Details shown are typical. Similar details apply in similar conditions.
Verify all architectural details with structural, civil, landscape and design/build drawings before ordering or installation of
any work.
All changes in floor materials occur at centerline of door or framed opening unless otherwise indicated on the drawings.
Install all fixtures, equipment and materials per manufacturer's recommendations.
Verify clearances for flues, vents, chases, soffits, fixtures, etc. before any construction, ordering of, or installation of any
items of work.
Sealant, caulking and flashing, etc. locations shown on drawings are not intended to be inclusive. Follow manufacturer's
installation recommendations and standard industry and building practices.
The General Contractor shall remove all rubbish and waste materials of all subcontractors and trades on a regular basis,
and shall exercise a strict control over job cleaning to prevent any direct debris or dust from affecting, in any way, finished
areas in or outside job site.
Contractor shall leave premises and all affected areas clean and orderly, ready for occupancy. This includes cleaning of all
glass (inside and outside) and frames, both new and existing.
Any survey monuments within the area of construction shall be preserved or reset by a registered civil engineer or a
licensed land surveyor.
Verify all finish materials with the Architect and the Owner prior to installation. On site mock-ups of building assemblies,
finish assemblies, paint and/or stain samples, etc. may be required for approval.
Contractor to coordinate utilities shown on architectural drawings with electrical, plumbing, mechanical, and any other
consultant drawings. Contractor to coordinate all the trades.
Structural observation shall be required by the Engineer for structural conformance to the approved plans.
It is the General Contractors responsibility to obtain inspections and special inspections as necessary.
All construction to provide a waterproof, weather tight building. Contractor should flash and caulk as necessary to achieve
this requirement.
S. South
-
CONTACT:
-
-
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
SHEET INDEX
NOT INCLUDED IN THIS SET
INCLUDED IN THIS SET
DATES ISSUEDSHEETTITLE
DELETED FROM SET
MECHANICAL DESIGN:
-
-
CONTACT:
-Tel: (XXX) XXX-XXXX
Email:
Tel: (XXX) XXX-XXXX
Email:
Tel: (XXX) XXX-XXXX
Email:
Tel: (XXX) XXX-XXXX
Email:
RE
V
I
E
W
S
E
T
DE
C
E
M
B
E
R
0
1
,
2
0
2
0
G-000 COVER SHEET
SURVEY SURVEY PLAT
PROJECT ADDRESS:
PARCEL ID:
FIRE SPRINKLER SYSTEM INSTALLED:
APPLICABLE CODES:
·2015 IRC (International Residential Code) Chapters 1-10
·2015 IRC appendixes:
·Manufactured homes, F: Radon, J: Existing Buildings & Structures, H:Patio Covers, K: Sound Transmission.
·2015 IPC (International Plumbing Code)
·2015 IMC (International Mechanical Code)
·2015 IFGC (International Fuel Gas Code)
·2015 IECC (International Energy Conservation Code) - Prescriptive Path
·2015 IFC (International Fire Code)
·2017 NEC (National Electrical Code)
CONTACT: Ryan Doremus
OWNER/CLIENT:
ARCHITECT:
Aspen, CO 81611
Thunderbowl Architects
300 Spring St. Suite 201
Email: ryan@thunderbowlarchitects.com
CONTRACTOR
Tel: (970) 274-1421
Steeplechase Construction
CONTACT: Steve Waldeck
124 Totterdown Rd
Aspen, CO 81611
Tel: (970) 920-4079
Email: steve@steeplechaseconstruction.com
303 PARK AVENUE
CONTACT:
623 E. Hopkins Ave
Aspen, CO 81611
Tel: (970) 920-1280
Email:
G-001 FIRE AREA PLAN
Z-100X EXIST/PROP AREA SHEET
A-100 EXIST/PROP LOWER LEVEL FP
A-101 EXIST/PROP LOWER LEVEL RCP
A-110 EXIST/PROP MAIN LEVEL FP
A-111 EXIST/PROP MAIN LEVEL RCP
A-120 EXIST/PROP UPPER LEVEL FP
A-121 EXIST/PROP UPPER LEVEL RCP
A-200 EXIST/PROP EXTERIOR ELEVATIONS
A-400 STAIR / RAILING DETAILS
A-600 DOOR/WINDOW DETAILS
PE
R
M
I
T
S
E
T
DE
C
E
M
B
E
R
3
0
,
2
0
2
0
PROJECT
SCALE
3/16" = 1'-0"
20017.00
G-000
COVER SHEET
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP DWN
CARPORT
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
DWN
UPPER
DECK
UPPER
DECK
781.73 SQ. FT.
1248.67 SQ. FT.
1056.46 SQ. FT.
3,086.86 SQ. FT.
AREA SQFT
LOWER LEVEL
MAIN LEVEL
UPPER LEVEL
TOTAL SF
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP
W
D
FRZ
LOWER
DECK
LOWER LEVEL
FLOOR AREA PLAN
1/8" = 1'-0"
1
G-001
PROJECT
SCALE
1/8" = 1'-0"
20017.00
G-001
FIRE AREA PLAN
MAIN LEVEL
FLOOR AREA PLAN
1/8" = 1'-0"
3
G-001
UPPER LEVEL
FLOOR AREA PLAN
1/8" = 1'-0"
3
G-001
AREA PLAN
LEGEND
PROPOSED FIRE AREA
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
UP
PA
R
T
Y
W
A
L
L
(
N
O
C
H
A
N
G
E
)
LOWER LEVEL FLOOR AREA
659.82 SQ. FT.
LOWER LEVEL DECK
186.7 SQ. FT.
UP DWN
MAIN LEVEL FLOOR AREA
683.78 SQ. FT.
MAIN LEVEL DECK
127.45 SQ. FT.
PA
R
T
Y
W
A
L
L
(
N
O
C
H
A
N
G
E
)
GARAGE FLOOR AREA
299.72 SQ. FT.
DWN
UPPER LEVEL FLOOR AREA
885.26 SQ. FT.
UPPER LEVEL DECK
268.77 SQ. FT.
PA
R
T
Y
W
A
L
L
(
N
O
C
H
A
N
G
E
)
UPPER LEVEL DECK 2
63.96 SQ. FT.
DWN
UPPER LEVEL FLOOR AREA
885.26 SQ. FT.
UPPER LEVEL DECK
268.77 SQ. FT.
PA
R
T
Y
W
A
L
L
(
N
O
C
H
A
N
G
E
)
UPPER LEVEL DECK 2
63.96 SQ. FT.
UP DWN
MAIN LEVEL FLOOR AREA
683.78 SQ. FT.
MAIN LEVEL DECK
127.45 SQ. FT.
PA
R
T
Y
W
A
L
L
(
N
O
C
H
A
N
G
E
)
GARAGE FLOOR AREA
299.72 SQ. FT.
UP
W
D
FRZ
PA
R
T
Y
W
A
L
L
(
N
O
C
H
A
N
G
E
)
LOWER LEVEL FLOOR AREA
659.82 SQ. FT.
LOWER LEVEL DECK
186.7 SQ. FT.
EXISTING & PROPOSED
AREA & DEMO CALCULATIONS *NO CHANGE TO FAR, FOOTPRINT, OR SF AREA
LOWER LEVEL
LL INTERIOR AREA
LL DECK AREA
TOTAL
MAIN LEVEL
ML INTERIOR AREA
ML GARAGE AREA
ML DECK AREA
TOTAL
UPPER LEVEL
UL INTERIOR AREA
UL DECK AREA
TOTAL
TOTAL INTERIOR AREA(+GAR)
TOTAL DECK AREA
TOTAL
DEMO CALCULATIONS
LOWER LEVEL EXISTING AREA
LOWER LEVEL DEMO AREA
DEMO AREA %
MAIN LEVEL EXISTING AREA
MAIN LEVEL DEMO AREA
DEMO AREA %
UPPER LEVEL EXISTING AREA
UPPER LEVEL DEMO AREA
DEMO AREA %
TOTAL SF AREA
TOTAL DEMO AREA
TOTAL DEMO AREA %
659.82 SF
186.7 SF
846.52 SF
683.78 SF
299.72 SF
127.45 SF
1,110.95 SF
885.26 SF
332.73 SF
1,217.99
2,528.58 SF
646.88 SF
3,175.46 SF
659.82
152.69
23.1 %
983.5
158.07
16%
885.26
262.33
29.6%
2,528.58
573.09
22.66% DEMO
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
PROJECT
SCALE
############
20017.00
Z-100X
EXISTING-PROP
AREA DEMO
CALCS
EXISTING LOWER AREA
1/8" = 1'-0"
1
Z-100X
EXISTING MAIN AREA
1/8" = 1'-0"
2
Z-100X
EXISTING UPPER AREA
1/8" = 1'-0"
3
Z-100X
PROPOSED LOWER AREA
1/8" = 1'-0"
4
Z-100X
PROPOSED MAIN AREA
1/8" = 1'-0"
5
Z-100X
PROPOSED UPPER AREA
1/8" = 1'-0"
6
Z-100X
EXISTING/PROPOSED
AREA & DEMO CALCS
1/8" = 1'-0"
7
Z-100X
LEGEND SEE A0.00 FOR SYMBOLS
NOT SHOWN HERE.
EXISTING/PROP INT AREA
EXISTING/PROP DECK AREA
EXISTING/PROP GARAGE AREA
DEMO AREA
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP
W
D
FRZ
3'-3 21/32"17'-10 27/32"
11
'
-
6
3
/
4
"
17
'
-
4
1
/
4
"
4'-0"
12
'
-
3
1
/
2
"
3'
-
6
"
3'
-
1
0
"
UTILITY
000
BR 1
000
BATH 1
000
CLST 1
000
LDRY
000
12'-8 1/2"
5'
-
9
"
3'-6 1/2"4'-11"
4'-5 11/16"2'-6"12'-5 13/16"
4'-5 11/16"2'-10"7'-8 9/16"5 1/2"4'-3 3/4"
1'-8 1/2"
2'-8"
8"
9'
-
7
1
/
8
"
2'
-
1
0
1
/
2
"
1 2 3
8 9
NEW BATHROOM
1 2 3
5 6
NEW CLOSETS
8
1 2 3
5 6 7
8
2 5 8
15 16
1 2 3
4 5 6
7 8
1 2 3
4 5 6
7 8
NEW 4 PANEL SLIDER @ EXISTING
LOCATION
*ALL NEW WINDOW/DOOR GLAZING
TO BE .28 OR LOWER U-VALUE
12
7
R
I
S
E
R
S
@
7
-
1
/
2
"
6
T
R
E
A
D
S
@
1
1
"
4,5,6
A-502
1,2
A-500
AREA OF BRICK
EXTERIOR MATERIAL
2'
-
8
"
5'
-
0
"
5'
-
6
"
2'
-
2
9
/
3
2
"
CLST 2
000
EXISTING WINDOW TO
BE REPLACED WITH
SAME SIZE
*TO BE .28 OR LOWER U-VALUE
2'
-
6
"
10
"
5'
-
1
0
1
/
4
"
EXTERIOR RAILING TO
MATCH NEIGHBORING UNIT
RAILING
*SEE 3/A-500
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP
OFFICE
000
BEDROOM
000
SAUNA
000
UTILITY
000
LDRY
000
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
N
0 2 4 8
Scale: 1/4" = 1'-0"
LOWER LEVEL EXISTING FP
1/4" = 1'-0"
1
A-100
PROJECT
SCALE
1/4" = 1'-0"
20017.00
A-100
EXIST-PROP
LOWER LEVEL
FLOOR PLAN
LOWER LEVEL PROPOSED FP
1/4" = 1'-0"
2
A-100
ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR
WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH.
OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH.
PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP.
PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER
AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE
DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE.
FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL
HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES,
PORTLANT CEMENT OR EQ.
1.
2.
3.
4.
5.
LEGEND SEE A0.00 FOR SYMBOLS
NOT SHOWN HERE.
FLOOR PLAN
GENERAL NOTES
(E) CONST. TO BE REMOVED
OR
NEW MASONRY WALL
2 HOUR RATED CONST.
1 HOUR RATED CONST.
NEW CONSTRUCTION
EXISTING CONSTRUCTION
KEY NOTES
LEGEND: LOWER LEVEL PROPOSED
NEW FLOORING TO BE INSTALLED1
NEW WALL PAINT. COLOR TBD2
NEW TRIM/ AND OR BASE PAINT COLOR TBD
3
4
NEW LIGHTING TO BE INSTALLED
5
NEW SWITCH/ OUTLET WALL PLATES TO BE INSTALLED
6
7
NEW DOOR/ HARDWARE TO BE INSTALLED
8
9
NEW FIREPLACE SURROUND
10
UPDATE BATHROOMS: NEW FIXTURES, FINISHES, TOILET,
TUB/SHOWER, VANITY
11
12
13
14
UPDATE LAUNDRY ROOM: NEW FIXTURES, FINISHES,
APPLIANCES, COUNTERTOP
15
16
17
18
NEW RETURN AND SUPPLY AIR GRATES TO BE INSTALLED
19
20
21
22
NEW CEILING PAINT. COLOR TBD
NEW PELLA ARCHITECTURAL SERIES WINDOWS TO BE
INSTALLED
NEW CABINET FRONTS TO BE INSTALLED
UPDATE KITCHEN: NEW FIXTURES, FINISHES, APPLIANCES,
COUNTERTOP. APPLIANCE LOCATION TO REMAIN
NEW INTERIOR STAIR STEEL HAND RAILING WITH GLASS
INFILL TO BE INSTALLED
NEW INTERIOR STAIR WOOD TREAD TO BE INSTALLED.
STRUCTURE TO REMAIN
NEW FRONT DOOR TO BE INSTALLED
NEW GARAGE DOOR TO BE INSTALLED
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP
W
D
FRZ
UTILITY
000
BR 1
000
BATH 1
000
CLST 1
000
LDRY
000
SD
SD
CO
CLST 2
000
WR
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP
OFFICE
000
BEDROOM
000
SAUNA
000
UTILITY
000
LDRY
000
SD
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
N
0 2 4 8
Scale: 1/4" = 1'-0"
LOWER LEVEL EXISTING RCP
1/4" = 1'-0"
1
A-101
PROJECT
SCALE
1/4" = 1'-0"
20017.00
A-101
EXIST-PROP
LOWER LEVEL
RCP
LOWER LEVEL PROPOSED RCP
1/4" = 1'-0"
2
A-101
LEGEND SEE COVER SHEET FOR
SYMBOLS NOT SHOWN HERE.
REFLECTED CEILING PLAN
GENERAL NOTES
SP
ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED
OTHERWISE.
VERIFY IN FIELD ALL EXISTING DIMENSIONS.
LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING
DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING.
ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP.
PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN
WHICH THEY APPEAR.
COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE.
1.
2.
3.
4.
5.
6.
+8'-0"
EXISTING CEILING MOUNTED FIXTURE
AIR OUTLET, VERIFY WITH MECH. SUB.
AIR INTAKE, VERIFY WITH MECH. SUB.
SMOKE DETECTOR, CARBON MONOXIDE
SPEAKER, VERIFY AV REQUIREMENTS
WITH OWNER
CEILING/SOFFIT HEIGHT SYMBOL
C.O.
S.D.
CEILING MOUNTED DECORATIVE PENDANT
WALL SCONCE
PROPOSED CEILING MOUNTED FIXTURE
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP DWN
MST BR
000
MST BATH
000
MST CLST 2
000
MUD RM
000
ENTRY
000
MST CLST 1
000
GARAGE
000
4'-7 9/16"11'-10"
4'
-
0
"
9'
-
5
1
/
4
"
5
1
/
2
"
3'
-
0
"
6'-8 1/2"6'-3 1/8"5 1/2"3'-6 3/8"5 1/2"7'-3 1/8"
5'
-
2
"
5'
-
0
1
/
8
"
5
1
/
2
"
5'
-
1
0
3
/
4
"
11
'
-
5
1
/
2
"
3'-8 5/8"
1'
-
8
"
2'
-
6
"
2'
-
6
1
/
4
"
2'
-
8
"
5'
-
9
1
/
1
6
"
2'-6"
1 2 3
8 9
NEW BATHROOM
1 2 3
4 5 6
7 8
1 2 3
5 6
NEW CLOSETS
8
1 2 3
5 6
NEW CLOSETS
8
1 2 3
5 6
NEW CLOSETS
8
17
REPLACED 4 PANEL SLIDER
*ALL NEW WINDOW/DOOR GLAZING
TO BE .28 OR LOWER U-VALUE
EXISTING WINDOW TO
BE REPLACED WITH
SAME SIZE
EXISTING WINDOW TO
BE REPLACED WITH
SAME SIZE
NEW FRONT DOOR
*ALL NEW WINDOW/DOOR GLAZING
TO BE .28 OR LOWER U-VALUE
2 5 8
15 16
7
R
I
S
E
R
S
@
7
-
1
/
2
"
6
T
R
E
A
D
S
@
1
1
"
7
R
I
S
E
R
S
@
7
-
1
/
2
"
6
T
R
E
A
D
S
@
1
1
"
4,5,6
A-502
1,2
A-500
AREA OF BRICK
EXTERIOR MATERIAL
4'-8 7/16"
3'-3 11/16"
3'
-
6
3
/
1
6
"
2'-8"
2'
-
9
1
/
2
"
3'
-
0
"
2
1
/
2
"
MST CLST 3
000
2'
-
6
"
EXTERIOR RAILING TO
MATCH NEIGHBORING UNIT
RAILING
*SEE 3/A-500
MST BR
000
1 3
E
A
B
C
D
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP DWN
MST CLST
000
MST BATH
000
GARAGE
000
FOYER
000
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
N
0 2 4 8
Scale: 1/4" = 1'-0"
MAIN LEVEL EXISTING FP
1/4" = 1'-0"
1
A-110
PROJECT
SCALE
1/4" = 1'-0"
20017.00
A-110
EXIST-PROPOSED
MAIN LEVEL
FLOOR PLAN
MAIN LEVEL PROPOSED FP
1/4" = 1'-0"
2
A-110
ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR
WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH.
OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH.
PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP.
PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER
AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE
DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE.
FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL
HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES,
PORTLANT CEMENT OR EQ.
1.
2.
3.
4.
5.
LEGEND SEE A0.00 FOR SYMBOLS
NOT SHOWN HERE.
FLOOR PLAN
GENERAL NOTES
(E) CONST. TO BE REMOVED
OR
NEW MASONRY WALL
2 HOUR RATED CONST.
1 HOUR RATED CONST.
NEW CONSTRUCTION
EXISTING CONSTRUCTION
KEY NOTES
LEGEND: LOWER LEVEL PROPOSED
NEW FLOORING TO BE INSTALLED1
NEW WALL PAINT. COLOR TBD2
NEW TRIM/ AND OR BASE PAINT COLOR TBD
3
4
NEW LIGHTING TO BE INSTALLED
5
NEW SWITCH/ OUTLET WALL PLATES TO BE INSTALLED
6
7
NEW DOOR/ HARDWARE TO BE INSTALLED
8
9
NEW FIREPLACE SURROUND
10
UPDATE BATHROOMS: NEW FIXTURES, FINISHES, TOILET,
TUB/SHOWER, VANITY
11
12
13
14
UPDATE LAUNDRY ROOM: NEW FIXTURES, FINISHES,
APPLIANCES, COUNTERTOP
15
16
17
18
NEW RETURN AND SUPPLY AIR GRATES TO BE INSTALLED
19
20
21
22
NEW CEILING PAINT. COLOR TBD
NEW PELLA ARCHITECTURAL SERIES WINDOWS TO BE
INSTALLED
NEW CABINET FRONTS TO BE INSTALLED
UPDATE KITCHEN: NEW FIXTURES, FINISHES, APPLIANCES,
COUNTERTOP. APPLIANCE LOCATION TO REMAIN
NEW INTERIOR STAIR STEEL HAND RAILING WITH GLASS
INFILL TO BE INSTALLED
NEW INTERIOR STAIR WOOD TREAD TO BE INSTALLED.
STRUCTURE TO REMAIN
NEW FRONT DOOR TO BE INSTALLED
NEW GARAGE DOOR TO BE INSTALLED
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP DWN
MST BR
000
MST BATH
000
MST CLST 2
000
MUD RM
000
ENTRY
000
MST CLST 1
000
GARAGE
000
SD
SD
CO
MST CLST 3
000
WR
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
UP DWN
MST BR
000
MST CLST
000
MST BATH
000
GARAGE
000
FOYER
000
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
N
0 2 4 8
Scale: 1/4" = 1'-0"
MAIN LEVEL EXISTING RCP
1/4" = 1'-0"
1
A-111
PROJECT
SCALE
1/4" = 1'-0"
20017.00
A-111
EXIST-PROP MAIN
LEVEL RCP
MAIN LEVEL PROPOSED RCP
1/4" = 1'-0"
2
A-111
LEGEND SEE COVER SHEET FOR
SYMBOLS NOT SHOWN HERE.
REFLECTED CEILING PLAN
GENERAL NOTES
SP
ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED
OTHERWISE.
VERIFY IN FIELD ALL EXISTING DIMENSIONS.
LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING
DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING.
ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP.
PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN
WHICH THEY APPEAR.
COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE.
1.
2.
3.
4.
5.
6.
+8'-0"
EXISTING CEILING MOUNTED FIXTURE
AIR OUTLET, VERIFY WITH MECH. SUB.
AIR INTAKE, VERIFY WITH MECH. SUB.
SMOKE DETECTOR, CARBON MONOXIDE
SPEAKER, VERIFY AV REQUIREMENTS
WITH OWNER
CEILING/SOFFIT HEIGHT SYMBOL
C.O.
S.D.
CEILING MOUNTED DECORATIVE PENDANT
WALL SCONCE
PROPOSED CEILING MOUNTED FIXTURE
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
DWN
DINING
000
LIVING
000
KITCHEN
000
BEDROOM 2
000
OFFICE
000
BATH 2
000
11'-10"7'-6"5'-10"
3'
-
9
3
1
/
3
2
"
6'
-
8
"
9'
-
3
3
/
8
"
3
1
/
2
"
2'
-
0
"
9'
-
1
0
1
/
8
"
4'
-
5
1
/
1
6
"
17
'
-
1
3
/
4
"
9'-9 11/16"5 1/2"10'-9 1/16"
5'
-
0
"
5
1
/
2
"
2'
-
1
1
"
3'
-
0
3
/
1
6
"
4'-1 3/4"5 1/2"
1'
-
5
"
2'
-
4
"
5 1/2"3'-2 1/4"2'-6"
2'
-
0
"
4'
-
1
0
1
/
8
"
3'
-
0
"
1'
-
6
"
2'
-
6
"
2'-6"
1 2 3
4 5 6
7 8
1 2 3
4 5 6
7 8
1 2 3
8 9
NEW BATHROOM
NEW BATHROOM
1 2 3
4 5 6
7 8
1 2 3
4 5 6
7 8 11
2 5 8
15 16
NEW 4 PANEL SLIDER
*ALL NEW WINDOW/DOOR GLAZING
TO BE .28 OR LOWER U-VALUE
NEW GAS DIRECT VENT
FIREPLACE/SURROUND
*MONTIGO D3615
*VERIFY ALL FP DIMENSIONS &
CLEARANCES
EXISTING WINDOW TO
BE REPLACED WITH
SAME SIZE
EXISTING WINDOW TO
BE REPLACED WITH
SAME SIZE
7
R
I
S
E
R
S
@
7
-
1
/
2
"
6
T
R
E
A
D
S
@
1
1
"
4,5,6
A-502
1,2
A-500
AREA OF
BRICK EXTERIOR MAT'L
EXTERIOR RAILING TO
MATCH NEIGHBORING UNIT
RAILING
*SEE 3/A-500
BEDROOM 3
000
1 3
E
A
B
C
D
F
2
4'-0"22'-2"
26'-2"
57
'
-
1
0
"
5'
-
9
"
11
'
-
1
0
1
/
4
"
24
'
-
1
1
/
2
"
4'
-
0
3
/
4
"
12
'
-
0
1
/
2
"
DWN
BEDROOM 2
000
KITCHEN
000
DINING
000
LIVING
000
BATH 2
000
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
N
0 2 4 8
Scale: 1/4" = 1'-0"
UPPER LEVEL EXISTING FP
1/4" = 1'-0"
1
A-120
PROJECT
SCALE
1/4" = 1'-0"
20017.00
A-120
EXIST-PROPOSED
UPPER LEVEL
FLOOR PLAN
UPPER LEVEL PROPOSED FP
1/4" = 1'-0"
2
A-120
ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR
WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH.
OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH.
PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP.
PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER
AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE
DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE.
FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL
HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES,
PORTLANT CEMENT OR EQ.
1.
2.
3.
4.
5.
LEGEND SEE A0.00 FOR SYMBOLS
NOT SHOWN HERE.
FLOOR PLAN
GENERAL NOTES
(E) CONST. TO BE REMOVED
OR
NEW MASONRY WALL
2 HOUR RATED CONST.
1 HOUR RATED CONST.
NEW CONSTRUCTION
EXISTING CONSTRUCTION
KEY NOTES
LEGEND: LOWER LEVEL PROPOSED
NEW FLOORING TO BE INSTALLED1
NEW WALL PAINT. COLOR TBD2
NEW TRIM/ AND OR BASE PAINT COLOR TBD
3
4
NEW LIGHTING TO BE INSTALLED
5
NEW SWITCH/ OUTLET WALL PLATES TO BE INSTALLED
6
7
NEW DOOR/ HARDWARE TO BE INSTALLED
8
9
NEW FIREPLACE SURROUND
10
UPDATE BATHROOMS: NEW FIXTURES, FINISHES, TOILET,
TUB/SHOWER, VANITY
11
12
13
14
UPDATE LAUNDRY ROOM: NEW FIXTURES, FINISHES,
APPLIANCES, COUNTERTOP
15
16
17
18
NEW RETURN AND SUPPLY AIR GRATES TO BE INSTALLED
19
20
21
22
NEW CEILING PAINT. COLOR TBD
NEW PELLA ARCHITECTURAL SERIES WINDOWS TO BE
INSTALLED
NEW CABINET FRONTS TO BE INSTALLED
UPDATE KITCHEN: NEW FIXTURES, FINISHES, APPLIANCES,
COUNTERTOP. APPLIANCE LOCATION TO REMAIN
NEW INTERIOR STAIR STEEL HAND RAILING WITH GLASS
INFILL TO BE INSTALLED
NEW INTERIOR STAIR WOOD TREAD TO BE INSTALLED.
STRUCTURE TO REMAIN
NEW FRONT DOOR TO BE INSTALLED
NEW GARAGE DOOR TO BE INSTALLED
DWN
DINING
000
LIVING
000
KITCHEN
000
BEDROOM 2
000
OFFICE
000
BATH 2
000
SKYLTSKYLT
SKYLT SKYLT
SKYLT
BEAMS ABOVE
SLOPED CLNG FLAT CLNG
SD
CO
SD
DWN
BEDROOM 3
000BEDROOM 2
000
KITCHEN
000
DINING
000
LIVING
000
BATH 2
000
SD
SKYLTSKYLT
SKYLT SKYLT
SKYLT
BEAMS ABOVE
SLOPED CLNG FLAT CLNG
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
N
0 2 4 8
Scale: 1/4" = 1'-0"
UPPER LEVEL EXISTING RCP
1/4" = 1'-0"
1
A-121
PROJECT
SCALE
1/4" = 1'-0"
20017.00
A-121
EXIST-PROP UPPER
LEVEL RCP
UPPER LEVEL PROPOSED RCP
1/4" = 1'-0"
2
A-121
LEGEND SEE COVER SHEET FOR
SYMBOLS NOT SHOWN HERE.
REFLECTED CEILING PLAN
GENERAL NOTES
SP
ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED
OTHERWISE.
VERIFY IN FIELD ALL EXISTING DIMENSIONS.
LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING
DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING.
ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP.
PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN
WHICH THEY APPEAR.
COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE.
1.
2.
3.
4.
5.
6.
+8'-0"
EXISTING CEILING MOUNTED FIXTURE
AIR OUTLET, VERIFY WITH MECH. SUB.
AIR INTAKE, VERIFY WITH MECH. SUB.
SMOKE DETECTOR, CARBON MONOXIDE
SPEAKER, VERIFY AV REQUIREMENTS
WITH OWNER
CEILING/SOFFIT HEIGHT SYMBOL
C.O.
S.D.
CEILING MOUNTED DECORATIVE PENDANT
WALL SCONCE
PROPOSED CEILING MOUNTED FIXTURE
T.O. PLY @ MAIN LVL
+100'-0"
T.O. PLY @ MAIN LVL
+91'-0" (V.I.F.)
T.O. PLY @ UPPER LVL
+108'-9" (V.I.F.)
T.O. PLY @ MAIN LVL
+100'-0"
T.O. PLY @ MAIN LVL
+91'-0" (V.I.F.)
T.O. PLY @ UPPER LVL
+108'-9" (V.I.F.)
NO CHANGE TO
EXISTING BRICK AREA
T.O. PLY @ MAIN LVL
+100'-0"
T.O. PLY @ UPPER LVL
+108'-9" (V.I.F.)
T.O. PLY @ MAIN LVL
+100'-0"
T.O. PLY @ UPPER LVL
+108'-9" (V.I.F.)
ALL WINDOWS TO BE REPLACED
W/ .28 U-VALUE UNITS
*ALL SIZES & LOCATIONS
TO REMAIN THE SAME
T.O. PLY @ MAIN LVL
+100'-0"
T.O. PLY @ MAIN LVL
+91'-0" (V.I.F.)
T.O. PLY @ UPPER LVL
+108'-9" (V.I.F.)
ALL WINDOWS TO BE REPLACED
W/ .28 U-VALUE UNITS
*ALL SIZES & LOCATIONS
TO REMAIN THE SAME NO CHANGE TO
EXISTING BRICK AREA
ALL WINDOWS TO BE REPLACED
W/ .28 U-VALUE UNITS
*ALL SIZES & LOCATIONS
TO REMAIN THE SAME
NEW EXT RAILING TO MATCH
NEIGHBORING UNIT DETAILS
*SEE 3/A-500
3'
-
0
"
3'
-
0
"
3'
-
0
"
3'
-
0
"
T.O. PLY @ MAIN LVL
+100'-0"
T.O. PLY @ MAIN LVL
+91'-0" (V.I.F.)
T.O. PLY @ UPPER LVL
+108'-9" (V.I.F.)
NEW 4 PANEL
PATIO SLIDER @ EXISTING LOCATION
*ALL NEW WINDOW/DOOR
GLAZING TO BE .28 U VALUE OR
LESS
11'-10"
7'
-
1
1
/
3
2
"
11'-10"
7'
-
1
1
/
3
2
"
12'-8 1/2"
7'
-
1
1
/
3
2
"
NEW 4 PANEL
PATIO SLIDER @ EXISTING LOCATION
*ALL NEW WINDOW/DOOR
GLAZING TO BE .28 U VALUE OR
LESS
NEW 4 PANEL
PATIO SLIDER @ EXISTING LOCATION
*ALL NEW WINDOW/DOOR
GLAZING TO BE .28 U VALUE OR
LESS
NEW EXT RAILING TO MATCH
NEIGHBORING UNIT DETAILS
*SEE 3/A-500
3'
-
0
"
3'
-
0
"
3'
-
0
"
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
0 2 4 8
Scale: 3/16"=1'-0"
PROJECT
SCALE
1/8" = 1'-0"
20017.00
A-200
PROPOSED
EXTERIOR
ELEVATIONS
ALL ROOF PITCHES SHALL BE AS SHOWN ON THE ROOF PLAN.
VERIFY FRAMING HEIGHTS FOR WINDOWS AND DOORS WITH SELECTED
MANUFACTURERS ROUGH OPENING SPECIFICATIONS.
ALL DOWNSPOUTS TO BE TIED INTO PERIMETER DRAIN SYSTEM IF EXISTING OR
PROPOSED - UNLESS NOTED OTHERWISE. CONTRACTOR TO VERIFY ALL DOWNSPOUT
LOCATIONS.
CONTRACTOR SHALL VERIFY ALL EXTERIOR MATERIALS, FINISHES, AND COLORS WITH
THE OWNER AND THE ARCHITECT PRIOR TO INSTALLATION OR APPLICATION.
IF PROVIDED, SEE ENLARGED WALL SECTIONS FOR TYPICAL EXTERIOR ASSEMBLIES.
1.
2.
3.
4.
5.
ELEVATION / SECTION
GENERAL NOTES
EXISTING WEST ELEVATION
1/8" = 1'-0"
2
A-200
EXISTING SOUTH ELEVATION
1/8" = 1'-0"
3
A-200
EXISTING EAST ELEVATION
1/8" = 1'-0"
1
A-200
PROPOSED WEST ELEVATION
1/8" = 1'-0"
5
A-200
PROPOSED SOUTH ELEVATION
1/8" = 1'-0"
6
A-200
PROPOSED EAST ELEVATION
1/8" = 1'-0"
4
A-200
3'
-
0
"
3
3
/
8
"
3
3
/
8
"
3
3
/
8
"
3
3
/
8
"
10
"
8"
5 1/2"
EXISTING STRUCTURE
TO REMAIN
1"X2" STRIPS ATTACHED
TO FACE
*V.I.F
ALL NEW RAILING MATERIALS/
SIZING / DETAILS / PAINT - TO MATCH
EXISTING NEIGHBORING UNIT
EXT RAILING
2 - 2X10'S
*V.I.F
3.5"X5.5" POSTS TO
BE NOTCHED OUT @
HORIZONTAL MEMBERS
2 - 2X8'S
*V.I.F
1"X2" STRIPS ATTACHED
TO FACE
*V.I.F
FASCIA BOARD / TRIM
TO MATCH NEIGHBORING
UNIT
8'
-
7
1
/
4
"
3'
-
0
"
7
1
/
4
"
11"
7
1
/
2
"
11"
E.Q.V.I.F.E.Q.
EXISTING WINDOW
TO REMAIN
EXISTING FLOOR
STRUCTURE TO REMAIN
EXISTING FLOOR
STRUCTURE TO
REMAIN
EXISTING FLOOR
STRUCTURE TO
REMAIN
EXISTING
FLOOR
STRUCTURE TO
REMAIN
EXISTING STAIR
STRUCTURE TO
REMAIN
NEW STEEL
RAILINGS W/ GLASS
INFILL
NEW WOOD
FLOORING OVER
EXISTING
STRUCTURE
NEW WOOD
FLOORING ON
LANDING
NEW WOOD
FLOORING OVER
EXISTING STRUCTURE
NEW CEILING BELOW
LANDING
T.O. FINISH
@ LOWER LEVEL
91' 6-1/2"
V.I.F.
T.O. FINISH
@ MAIN LEVEL
100'-0"
V.I.F.
T.O. FINISH
@ UPPER LEVEL
108'-9"
V.I.F.
T.O. SLAB
@ GARAGE
95' 9-1/4"
V.I.F.
T.O. FINISH
@ LANDING
104' 4-1/2"
V.I.F.
NEW STEEL
STRINGERS
NEW STEEL
STRINGER
6" DIA
3'
-
0
"
SOLID WALL
3'
-
0
"
EXISTING WALL
TO REMAIN
EXISTING FLOOR STRUCTURE
TO REMAIN
EXISTING FLOOR STRUCTURE
TO REMAIN
NEW STEEL RAILINGS W/
GLASS INFILL
EXISTING WALL
TO REMAIN
T.O. FINISH
@ LOWER LEVEL
91' 6-1/2"
V.I.F.
T.O. FINISH
@ MAIN LEVEL
100'-0"
V.I.F.
T.O. FINISH
@ UPPER LEVEL
108'-9"
V.I.F.
T.O. FINISH
@ LANDING
104' 4-1/2"
V.I.F.
EXISTING
STRUCTURE TO
REMAIN
NEW STEEL
STRINGERS
NEW WOOD
FLOORING ON
LANDING
NEW STEEL
STRINGERS
(BEHIND)
4"
NEW TREADS
OVER EXISTING
STRUCTURE
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
PROPOSED
STAIR SECTION
1/2" = 1'-0"
2
A-400
0 1 2 4
Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"
PROPOSED
STAIR ELEVATION
1/2" = 1'-0"
1
A-400
PROJECT
SCALE
VARIES
20017.00
A-400
STAIR &
RAILING
DETAILS
EXT. RAILING DETAIL
1-1/2" = 1'-0"
3
A-400
3" = 1'-0"
SLIDING DOOR HEAD
AT WOOD SIDING
3" = 1'-0"
SLIDING DOOR JAMB
AT WOOD SIDING
INTERIOR
PE
R
P
L
A
N
3" = 1'-0"
SLIDING DOOR SILL
AT WOOD SIDING
INTERIOR EXTERIOR
SEE INTERIORS FOR FINISH
3
4" EXTERIOR WOOD SIDING
3
4" EXTERIOR WOOD SIDING
EXTERIOR PATIO PER PLANS
NON-EXPANDING SPRAY FOAM IN SHIM SPACE
BACKER ROD & SEALANT @ FLASHING
SEALANT AS REQUIRED
SEALANT AS REQUIRED
BACKER ROD & SEALANT
NON-EXPANDING SPRAY FOAM IN SHIM SPACE
EXISTING STRUCTURE
TO REMAIN
SLIDING DOOR PER SCHEDULE
NON-EXPANDING SPRAY FOAM IN SHIM SPACE
SLIDING DOOR PER SCHEDULE
EXTERIOR
INTERIOR EXTERIOR
PER PLANS
SLIDING DOOR PER SCHEDULE
SEALANT AS REQUIRED
T.O. FINISH @ FLOOR LEVEL
XXX' - 0"
HEADER AS REQUIRED
INTERIOR FINISH PER PLANS
BACKER ROD AND SEALANT
1/
2
"
3/
4
"
NOTCH 1
2" BELOW DOOR
FRAME
1
A-600
2
A-600
3
A-600
PROJECT
SCALE
20017.00
A-600
DOOR-WINDOW
DETAILS
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
27
3
7
1
8
1
3
8
0
0
1
30
3
P
A
R
K
A
V
E
.
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
11.25.2020 REVIEW
1.5.2020 PERMIT SET
3" = 1'-0"
TYP. WINDOW HEAD
3" = 1'-0"
TYP. WINDOW JAMB
INTERIOR
EX
I
S
T
I
N
G
S
T
R
U
C
T
U
R
E
3" = 1'-0"
TYP. WINDOW SILL
INTERIOR EXTERIOR
EXISTING STRUCTURE
SEE INTERIORS FOR FINISH
LINE OF SILL
EXTERIOR FINISH
SEALANT AS REQUIRED
NON-EXPANDING SPRAY FOAM IN SHIM SPACE
WINDOW PER SCHEDULE
EXTERIOR
EXISTING STRUCTURE
BACKER ROD AND SEALANT
INTERIOR EXTERIOR
NON-EXPANDING SPRAY FOAM IN SHIM SPACE
EXTERIOR FINISH
BACKER ROD & SEALANT
SEALANT AS REQUIRED
FINISH PER INTERIORS
WINDOW PER SCHEDULE
SEE INTERIORS FOR FINISH
EXTERIOR FINISH
SEALANT AS REQUIRED
BACKER ROD & SEALANT
NON-EXPANDING SPRAY FOAM IN SHIM SPACE
WINDOW PER SCHEDULE
4
A-600
5
A-600
6
A-600