HomeMy WebLinkAboutDN02071B_A and E_CDs_L600 - 11.06.2018 - FINAL CONST - 4900184499DN02071B APPROVAL SIGNATURE BLOCK Construction Manager (Print) The following parties have reviewed these documents. All documents are subject to review by the local zoning/building departments and may impose changes or modifications. RF Engineer (Print) Site Acquisition (Print) TMO Quality Assurance (Print) Construction Manager RF Engineer Site Acquisition TMO Quality Assurance Date Approved Rejected Date Approved Rejected Date Approved Rejected Date Approved Rejected Project Manager (Print)Project Manager Date Approved Rejected TITLE SHEET T1 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. A3 T1 TITLE SHEET DRAWING INDEX A4 NORTH ELEVATIONS EQUIPMENT LAYOUTS A5 ANTENNA LAYOUTS A6 RFDS DIAGRAM ANTENNA SPECIFICATIONS A8 OVERALL SITE PLANA1 SAFETY PLAN A7 GENERAL NOTESGN1 L600 315 EAST DEAN ST ASPEN, CO 81611 LATITUDE: 39.1869755° LONGITUDE: -105.821207° ST. REGIS DN02071B MODIFICATION OF AN EXISTING "NON-INHABITABLE" T-MOBILE TELECOMMUNICATIONS SITE - (4) NEW ANTENNAS - (4) RRU'S - (2) NEW SYSTEM MODULE N SITE PHOTO SCOPE OF WORKVICINITY MAP 1.THE FACILITY IS AN UNOCCUPIED WIRELESS FACILITY. 2.PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3.PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 4.THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 5.CONTRACTOR SHALL CONTACT LOCAL DIGGERS HOTLINE 48 HOURS PRIOR TO PROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION. 6.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 7.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. FROM 18400 EAST 22ND AVENUE AURORA, CO 80011: HEAD EAST ON E 22ND AVE TOWARD TOWER RD, TURN LEFT AT THE 1ST CROSS STREET ONTO TOWER RD, USE THE LEFT 2 LANES TO TURN LEFT TO MERGE ONTO I-70 W, MERGE ONTO I-70 W, USE THE RIGHT 2 LANES TO TAKE EXIT 195 FOR CO-91 S TOWARD COPPER MOUNTAIN/LEADVILLE, CONTINUE ONTO CO-91 S, CONTINUE ONTO US-24 E/N POPLAR ST, TURN RIGHT ONTO CO-82 W, TURN LEFT ONTO S ORIGINAL ST, TURN RIGHT ONTO E DURANT AVE, TURN LEFT ONTO S GALENA ST, TURN RIGHT AT THE 1ST CROSS STREET ONTO E DEAN ST, DESTINATION WILL BE ON THE LEFT. ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. GOVERNING CODES, AS APPLICABLE: IBC-2015 IRC-2015 IMC-2015 IPC-2015 NEC-2014 APPLICANT: SITE ACQUISITION: WYCO ENGINEERING SERVICES 3980 QUEBEC ST DENVER, CO 80207 MICHAEL LASITER 303.601.4269 T-MOBILE WEST LLC 18400 EAST 22ND AVENUE AURORA, CO 80011 303.313.6923 WYCO LAND SERVICES 3980 QUEBEC ST DENVER, CO 80207 ANNIE MACKIEWICZ 303.601.7241 A&E PROJECT MANAGER PROPERTY OWNER: T-MOBILE PROJECT MANAGEMENT JENNI BAKER 18400 EAST 22ND AVENUE AURORA, CO 80011 720.648.3172 SITE INFORMATION GENERAL CONSTRUCTION NOTES CODE COMPLIANCE PROJECT CONTACTS DRIVING DIRECTIONS SITE LOCATION SLC ASPEN DEAN STREET LLC 315 EAST DEAN STREET ASPEN, CO 81611 SITE TYPE:BUILDING - ROOFTOP SITE NAME:ST. REGIS SITE NUMBER:DN02071B SITE ADDRESS:315 EAST DEAN ST. ASPEN, CO 81611 JURISDICTION:TOWN OF ASPEN A.D.A. COMPLICANCE:NOT REQUIRED PER IBC 1103.2.9. RFDS DATE:3/21/2018 T-MOBILE CONSTRUCTION MANAGER 18400 EAST 22ND AVENUE AURORA, CO 80011 RICK SAWYER 303.521.8061 A2 EQUIPMENT DETAILS A8.1 EQUIPMENT DETAILS ST A C K E D MO D U L E S ST A C K E D MO D U L E S 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC OVERALL SITE PLAN A2 2 OVERALL SITE PLAN SCALE: 1/16" = 1'-0" Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. SCALE: 1/16"=1'-0" 8'0 16'32'48' (E) MULTI-STORY COMMERCIAL BUILDING (E) ROOFTOP PENTHOUISE W/ T-MOBILE ANTENNAS (E) T-MOBILE ROOFTOP PLATFORM (E) BUILDING ROOFTOP (E) PLAZA BELOW S M O N A R C H S T T-MOBILE PROJECT AREA SEE SHEET A4.0 E DEAN ST E DEAN ST S M O N A R C H S T N 1 T-MOBILE LEASE AREA PHOTO SCALE: N.T.S. ST A C K E D MO D U L E S ST A C K E D MO D U L E S ST A C K E D MO D U L E S 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC EQUIPMENT LAYOUT A2 2 PROPOSED EQUIPMENT PLAN SCALE: 3/4" = 1'-0" Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. SCALE: 3/4"=1'-0" 6"0 3'2'1' 1 EXISTING EQUIPMENT PLAN SCALE: 3/4" = 1'-0"SCALE: 3/4"=1'-0" 6"0 3'2'1' (E) T-MOBILE FCOA CABINET; REMOVE (3) (E) FSMF MOUDLES (E) T-MOBILE BBU TO REMAIN (E) T-MOBILE STACKED MODULES (E) T-MOBILE RAC 24 CABINET (E) T-MOBILE 100A PPC & TELCO CABINET (E) T-MOBILE COVP TO BE RELOCATED (E) T-MOBILE COVP TO BE RELOCATED (N) T-MOBILE STACKED UNISTRUT TABLES W/ (2) (N) AMOB MODULES (2) (E) T-MOBILE COVP RELOCATED TO (N) H-FRAME (N) T-MOBILE H-FRAME TO BE INSTALLED N N (E) DC POWER PLANT TO BE REPLACED WITH (1) (N) ESAA400-HCU01 400A DC POWER PLANT VIEW NORTH ELEVATIONS A3 2 PROPOSED NORTH ELEVATION SCALE: 1/16" = 1'-0" 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. SCALE: 1/16"=1'-0" 8'0 16'32'48' 1 EXISTING NORTH ELEVATION SCALE: 1/16" = 1'-0" EX. GRADE ELEV. 0'-0" TOP OF PENTHOUSE ELEV. 79'-0" CL OF T-MOBILE ANTENNAS ELEV. 77'-0" (E) METAL STAIRS TO PENTHOUSE (E) T-MOBILE ANTENNA TO REMAIN (ALPHA SECTOR) (E) PENTHOUSE ROOF TOP (E) BUILDING ROOF TOP (E) T-MOBILE EQUIPMENT ON METAL PLATFORM (NOT VISIBLE) (E) BUILDING EX. GRADE ELEV. 0'-0" TOP OF PENTHOUSE ELEV. 79'-0" CL OF T-MOBILE ANTENNAS ELEV. 77'-0" (E) BUILDING ROOF TOP (E) T-MOBILE EQUIPMENT ON METAL PLATFORM (NOT VISIBLE) (E) BUILDING (E) T-MOBILE ANTENNA TO REMAIN (DELTA SECTOR) (E) T-MOBILE ANTENNA TO BE REPLACED (ALPHA SECTOR) (E) PENTHOUSE ROOF TOP (N) T-MOBILE ANTENNA TO REPLACE (E) (TYP. PER SECTOR) (N) T-MOBILE ANTENNA TO REPLACE (E) (TYP. PER SECTOR) SCALE: 1/16"=1'-0" 8'0 16'32'48' NOTE: PAINT ANTENNAS TO MATCH (E) BLDG ( E ) A L P H A S E C T O R A Z I M U T H = 3 4 0 ° (E ) D E L T A S E C T O R AZI M U T H = 4 0 ° (E) BETA SECTOR AZIMUTH = 90° (E) G A M M A S E C T O R AZ I M U T H = 2 0 0 ° ( N ) A L P H A S E C T O R A Z I M U T H = 3 4 0 ° (N ) D E L T A S E C T O R AZI M U T H = 4 0 ° (N) BETA SECTOR AZIMUTH = 90° (N) G A M M A S E C T O R AZ I M U T H = 2 0 0 ° ANTENNA LAYOUT A4 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. SCALE: 1/4"=1'-0" 2'0 4'8'12' N SCALE: 1/4"=1'-0" 2'0 4'8'12' (E) T-MOBILE ANTENNA TO REMAIN (E) T-MOBILE ANTENNA TO BE REPLACED (E) T-MOBILE ANTENNA TO BE REPLACED (E) T-MOBILE ANTENNA TO BE REPLACED (E) T-MOBILE ANTENNA TO REMAIN (E) T-MOBILE ANTENNA TO REMAIN (E) T-MOBILE ANTENNA TO REMAIN (E) T-MOBILE ANTENNA TO BE REPLACED (E) T-MOBILE FRLB TO BE REPLACED (TYP. PER SECTOR) (E) T-MOBILE FRIG RRUS TO REMAIN (TYP. PER SECTOR) (E) T-MOBILE FHFB TO REMAIN (TYP. PER SECTOR) (E) T-MOBILE COVP TO REMAIN (TYP. PER SECTOR) (E) T-MOBILE TMAs TO REMAIN (TYP. PER SECTOR) (E) T-MOBILE FXFB TO REMAIN (TYP. PER SECTOR)(N) T-MOBILE AHLOA TO REPLACE FRLB (TYP. PER SECTOR) (N) T-MOBILE ANTENNA TO REPLACE (E) (N) T-MOBILE AHLOA RRU TO REPLACE (E) FRLB (TYP. PER SECTOR) (N) T-MOBILE ANTENNA TO REPLACE (E) (N) T-MOBILE AHLOA RRU TO REPLACE (E) FRLB (TYP. PER SECTOR) (N) T-MOBILE ANTENNA TO REPLACE (E) (N) T-MOBILE ANTENNA TO REPLACE (E) 3/28/2018 NOTES: - INFORMATION PER RFDS DATED: CONTRACTOR TO REFER TO MOST RECENT RFDS BY T-MOBILE PRIOR TO COMMENCING WORK. - REFER TO SHEET A5 FOR ANTENNA SPECIFICATIONS 1 RF SCHEDULE SCALE: N.T.S. 3 PROPOSED ANTENNA LAYOUT SCALE: 1/4" = 1'-0" 2 EXISTING ANTENNA LAYOUT SCALE: 1/4" = 1'-0" SECTOR POSITION EXISTING/PROPOSED ANTENNA GAMMA AZIMUTH CL MANUFACTURER - MODEL NUMBER TECHNOLOGY BETA ALPHA DELTA A1 A2 B1 B2 C1 C2 D1 D2 A1 A2 D1 D2 B1 B2 C2 C1 MECH. TILT ELEC. TILT FEED TYPE EXISTING EXISTING EXISTING EXISTING PROPOSED PROPOSED PROPOSED PROPOSED 340° 340° 90° 90° 200° 200° 40° 40° 77' 77' 77' 77' 77' 77' 77' 77' COMMSCOPE - TMBXX-6516-A2M COMMSCOPE - FFHH-65B-R3 COMMSCOPE - TMBXX-6516-A2M COMMSCOPE - FFHH-65B-R3 COMMSCOPE - TMBXX-6516-A2M COMMSCOPE - FFHH-65B-R3 COMMSCOPE - TMBXX-6516-A2M COMMSCOPE - FFHH-65B-R3 U1900/G1900 L600/L700/L1900/L2100 U1900/G1900 L600/L700/L1900/L2100 U1900/G1900 L600/L700/L1900/L2100 U1900/G1900 L600/L700/L1900/L2100 0 0 0 0 -3 -3 0 0 4/4 4/4/3/3 3/3 0/0/0/0 0/0 0/0/0/0 2/2 0/0/0/0 (E) MID-CAP HYBRID CABLE (E) LOW-CAP HYBRID CABLE (E) LOW-CAP HYBRID CABLE (E) LOW-CAP HYBRID CABLE N NOTE: PAINT ANTENNAS TO MATCH (E) BLDG NOTE: PER MA'S DATED: 10/26/18 ALL PROPOSED ANTENNA LOCATIONS ARE TO BE REPLACED WITH (N) COMMSCOPE MT-222L MOUNTS. (RE: A8.1 FOR DETAILS) (N) COMMSCOPE MT-222L PIPE MOUNT TO BE INSTALLED (TYP. PER SECTOR) (RE: A8.1 FOR DETAILS) 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC RFDS DIAGRAM A5 Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. 1 RFDS DIAGRAM SCALE: N.T.S. ST A C K E D MO D U L E S ST A C K E D MO D U L E S 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC SAFETY PLAN A6 1 SAFETY PLAN SCALE: 1/8" = 1'-0" Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. NOTE: THIS SITE MEETS OSHA COMPLIANCE FOR FIELD OPERATIONS TO ACCESS BTS EQUIPMENT IN LOWER LEVEL ROOM NOT SHOWN. RADIO AND ANTENNAS ON LOWER & UPPER PENTHOUSE ARE ACCESSIBLE WITH USE OF EXISTING SAFETY TIE OFF CABLES. (E) ROOFTOP ACCESS DOOR 3' SAFETY PATH TO EQUIPMENT LEGEND 15' FALL ZONE & INACCESSIBLE AREAS 3' WIDE SAFETY PATH TO EQUIPMENT 3' SAFETY PATH TO EQUIPMENT (E) ROOFTOP HVAC EQUIPMENT (TYP.) (E) ROOFTOP COVERS (TYP.) HVAC HVAC (E) ROOFTOP HVAC EQUIPMENT (TYP.) SCALE: 1/8"=1'-0" 4'0 8'16'24' N 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC ANTENNA SPECIFICATION A7 1 ANTENNA SPECIFICATIONS SCALE: N.T.S. Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. 3 RRU MOUNTING DETAIL SCALE: N.T.S. RRU MOUNTED TO FPKA FPKA CLAMPED & TIGHTENED TO PIPE TYP. x2 RRU MOUNTED TO FPKA FPKA CLAMPED & TIGHTENED TO PIPE TYP. x2 PIPE MOUNTED UNISTRUT MOUNTED (2) 1-5/8" UNISTRUT (VERTICAL OR HORIZONTAL INSTALL) UNISTRUT NUT & 3/8" NUT TYP. UNISTRUT TO WALL W/ 5/8" EXPANSION ANCHOR TYP. X2 PER UNISTRUT 3/8" BOLT & WASHER TYP. X4 PER RRU 4 SYSTEM / RADIO MODULE SPECIFICATIONS SCALE: N.T.S. 5. 2 5 " 22 " 19.3" 17.6" NOKIA FLEXI SYSTEM/RADIO MODULES FSMF, FSME, FRIE & FXFC CLEARANCES:FRONT: 23.6" BACK: 8" TOP: 1.2" SIDES: 4" WEIGHT:44 lbs ADDITIONAL NOTE:MODULE CAN BE INSTALLED VERTICALLY & HORIZONTALLY FPKA MOUNTING BRACKET MODULE PLINTH PIPE FCOA CABINET SYSTEM MODULE MOUNTED TO INTERIOR FCOA RACK STACKED SYSTEM MODULES NOKIA PLINTH BOLT PLINTH TO UNISTRUT PER NOKIA REQUIREMENTS 5/8" EXPANSION ANCHOR (CONC.) THRU BOLT 7"x7" BACKER PLATE (GRATE) (x2 PER BASE) TYP. SURFACE TOP SIDE P1000 1-5/8" UNISTRUT FRAME 36 " M I N . (4) P2072A BASE UNISTRUT BRACKET 1 RRU SPECIFICATIONS (AHFIB) SCALE: N.T.S. 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC EQUIPMENT DETAILS A8 Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. 2 AMOB SYSTEM MODULE DETAIL SCALE: N.T.S. 1'-0" 8" 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC EQUIPMENT DETAILS A8.1 Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts. 1 STACKED UNI-STRUT TABLE DETAIL SCALE: 3/4" = 1'-0" (2) (N) T-MOBILE UNI-STRUT TABLES (2) (N) T-MOBILE AMOB SYSTEM MODULES 36 " M I N . 15 " M I N . P1000 1 5/8" UNI-STRUT FRAME SURFACE (4) P2072A BASE UNISTRUT BRACKET THRU BOLT 7"X7" BACKER PLATE (GRATE) (X2 PER BASE) TYP. UNISTRUT CAPS INSTALLED @ ENDS TYP. 2 COMMSCOPE MT-222L DETAIL SCALE: N.T.S. 3 NOT USED SCALE: N.T.S. 4 NOT USED SCALE: N.T.S. EX. SOLID/CONCRETE/BRICK/CMU WALL ANDREW WALL MOUNT (P/N MT-222L) 2.0" STD MOUNTING PIPE (7' LONG; TRIM TO FIT) W/ (1) 1/2" A307 U-BOLT PER CONNECTION (4) 1/2" DIA HILTI KWIK-BOLT TZ W/ 2" MIN EMBEDMENT INTO (E) WALL 1 10/03/18 PRELIMINARY EC ST. REGIS DN02071B ATC SITE #: CO-332094 315 EAST DEAN ST ASPEN, CO 81611 PITKIN COUNTY EC ML MN 2 11/06/18 FINAL CONST.EC GENERAL NOTES GN1 GENERAL CONSTRUCTION NOTES 1.THE FACILITY IS AN UNOCCUPIED WIRELESS FACILITY. 2.PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3.PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION ENGINEER AND ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 4.THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. 5.CONTRACTOR SHALL CONTACT LOCAL DIGGERS HOTLINE 48 HOURS PRIOR TO PROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION. 6.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 7.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8.THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE CONSTRUCTION FIELD ENGINEER AND WITH THE LANDLORD'S AUTHORIZED REPRESENTATIVE. 9.DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 10.REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE PLOT OF SURVEY DRAWING, SHALL NOT BE USED TO IDENTIFY OR ESTABLISH THE BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE PLAT OF SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO NOTIFY THE ARCHITECT/ENGINEER. STRUCTURAL NOTES 1.0 GENERAL CONDITIONS 1.1 DESIGN AND CONSTRUCTION OF ALL WORK SHALL CONFORM TO THE APPROVED EDITION OF THE IBC EDITION AND ALL OTHER APPLICABLE STATE CODES, ORDINANCES, AND REGULATIONS. IN CASE OF CONFLICT BETWEEN THE CODES, STANDARDS, AND REGULATIONS. SPECIFICATIONS, GENERAL NOTES AND/OR MANUFACTURER'S REQUIREMENTS. USE THE MOST STRINGENT PROVISION. 1.2 IT IS THE EXPRESS INTENT OF THE PARTIES INVOLVED IN THIS PROJECT THAT THE CONTRACTOR OR SUBCONTRACTOR OR INDEPENDENT CONTRACTOR OR THEIR RESPECTIVE EMPLOYEES SHALL EXCULPATE THE ARCHITECT, THE ENGINEER, THE CONSTRUCTION MANAGER, THE OWNER, AND THEIR AGENTS, FROM ANY LIABILITY WHATSOEVER AND HOLD THEM HARMLESS AGAINST LOSS, DAMAGES, LIABILITY OR ANY EXPENSE ARISING IN ANY MATTER FROM THE WRONGFUL OR NEGLIGENT ACT, OR FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, OR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OR FAILURE TO CONFORM TO THE STATE SCAFFOLDING ACT IN CONNECTION WITH THE WORK. 1.3 DO NOT SCALE DRAWINGS. 1.4 VERIFY ALL EQUIPMENT MOUNTING DIMENSIONS PER MANUFACTURER DRAWINGS. 1.5 SUBMIT ONE SEPIA AND TWO PRINTS OF ALL STRUCTURAL SHOP DRAWINGS. MARKED UP SEPIA SHALL BE RETURNED. STRUCTURAL STEEL NOTES: 1.CHANNELS, ANGLES AND PLATES SHALL BE ASTM A36 MATERIAL, UNLESS NOTED OTHERWISE. 2.SQUARE AND RECTANGULAR TUBE STEEL HSS SECTIONS SHALL BE ASTM A500, GRADE B (Fy = 46 ksi) MATERIAL. 3. ROUND PIPE SECTIONS SHALL BE ASTM A53, GRADE B (Fy =35 ksi) MATERIAL. 4.DESIGN, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE “AISC SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS”, WITH COMMENTARY AND THE “CODE OF STANDARD PRACTICE”. 5.ALL STEEL SHALL HAVE ONE COAT OF SHOP PRIMER. DO NOT PAINT AREAS WITHIN 3” OF BOLTS, WELDS OR HEADED STUDS. 6.BOLTS SHALL BE HIGH STRENGTH BOLTS, A325, CONFORMING TO ASTM SPECIFICATIONS. ALL CONNECTIONS SHALL HAVE A MINIMUM OF 2 BOLTS. 7.WELDING SHALL BE CONDUCTED BY CERTIFIED WELDERS AND SHALL CONFORM TO THE AWS CODES FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION. 8.WELDS SHALL BE MADE USING E70XX ELECTRODES AND SHALL BE 3/16" MINIMUM UNLESS OTHERWISE NOTED. 9.WELDING SHALL BE PERFORMED IN ACCORDANCE WITH A WELDED PROCEDURE SPECIFICATION (WPS) AS PER AWS D1.1 , D1.3 AND D1.4. 10.ONLY PRE-QUALIFIED WELDING PROCEDURES SHALL BE USED. 11.UNLESS SPECIFICALLY ADDRESSED IN THE SPECIFICATIONS OR THE DETAILS, ALL STEEL ITEMS PERMANENTLY EXPOSED TO EARTH OR WEATHER SHALL BE CORROSION-RESISTANT BY GALVANIZING OR BY THE USE OF STAINLESS STEEL. 12.ALL FIELD WELDS ON GALVANIZED MATERIAL SHALL BE BRUSH-COATED WITH A ZINC-RICH PAINT. FRP Notes: 1.ALL FRP MATERIAL SHALL BE EXTREN SERIES 500 OR EQUIVALENT, PRODUCED BY THE PULTRUSION METHOD. 2.ALL ADHESIVE RESIN SHALL BE PLEXUS METHACRYLATE OR AN EQUIVALENT ADHESIVE RESIN THAT IS COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPES. 3.ALL FRP CONNECTIONS SHALL BE FULLY-BONDED AT EACH SIDE WITH A 1/4” PLATE AND A MINIMUM OF (2) 3/8” DIAMETER FLATHEAD FRP SCREWS PER MEMBER. 4.ISOPLAST NUTS AND BOLTS SHALL BE TIGHTENED TO A SNUG-TIGHT FIT PLUS AN ADDITIONAL 1/2 TURN, PRIOR TO BEING LOCKED WITH EPOXY. 5.ALL PANELS / SHEATHING SHALL BE FULLY BONDED WITH 3/8” FLATHEAD FRP SCREWS AT 12” O.C. 6.ALL FIELD CUT AND DRILLED EDGES, HOLES AND ABRASIONS SHALL BE SEALED WITH A CATALYZED EPOXY RESIN COMPATIBLE WITH THE MANUFACTURER'S ORIGINAL RESIN. 3.0 STANDARDS FOR ALL CONCRETE WORK 3.1 ALL CONCRETE WORK SHALL CONFORM WITH ACI. 318 OR LATEST. DETAIL REINFORCING IN CONFORMANCE WITH ACI. SP66 LATEST. 3.2 NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES WHERE PERMITTED SHALL BE A MINIMUM OF 30 BAR DIAMETERS. 3.3 PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING AT POSITIONS SHOW ON DRAWINGS. 3.4 WIRE FABRIC REINFORCEMENT MUST LAP ONE FULL MESH AT SIDE AND END LAPS SHALL BE TIED TOGETHER. 3.5 CURE AFTER FINISHING CONCRETE. KEEP MOIST FOR 7 DAYS AFTER POURING. 3.6 COMPACT STRUCTURAL FILL 95% PROCTOR DENSITY PRIOR TO PLACING CONCRETE UNDER SLABS. 3.7 1/4" CHAMFER ON ALL CORNERS AND EDGES. 3.8 ALL CONCRETE SHALL BE PORTLAND, TYPE 1 CEMENT WITH A MINIMUM OF 28 DAY STRENGTH OF 3000 PSI., 4" SLUMP AND A MINIMUM AIR ENTRAPMENT OF 4%. 3.9 ALL REINFORCING STEEL SHALL BE GRADE 60. ALL REINFORCING MESH SHALL CONFORM TO ASTM A 185. ELECTRICAL NOTES 1.SUBMITTAL OF BID INDICATES CONTRACTOR IS COGNIZANT OF ALL JOB SITE CONDITIONS AND WORK TO BE PREFORMED UNDER THIS CONTRACT. CONTRACTOR IS RESPONSIBLE FOR ALL FIELD VERIFICATION. 2.THESE PLANS ARE DIAGRAMMATIC ONLY, AND NOT TO BE SCALED. 3.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, INSURANCE, EQUIPMENT, INSTALLATION, CONSTRUCTION TOOLS, TRANSPORTATION, ETC. FOR A COMPLETE AND PROPERLY OPERATIVE SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED ON DRAWINGS, AS SPECIFIED HEREIN AND/OR AS OTHERWISE REQUIRED. 4.ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND SHALL BE OF THE BEST GRADE OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY UNDER-WRITER'S LABORATORY AND SHALL BEAR THE INSPECTION LABEL "J" WHERE SUBJECT TO SUCH APPROVAL MATERIALS SHALL MEET WITH APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS ESTABLISHED BY ANSI, NEMA AND NBFU. 5.ALL CONDUIT INSTALLED SHALL BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 6.ELECTRICAL CONTRACTOR SHALL CARRY OUT HIS WORK WITH ACCORDANCE WITH ALL GOVERNING STATE, COUNTY, LOCAL CODES AND O.S.H.A. 7.ELECTRICAL CONTRACTOR SHALL SECURE ALL NECESSARY ELECTRICAL PERMITS, AND PAY ALL REQUIRED FEES. 8.COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF NO LESS THAN ONE YEAR AFTER THE DATE OF JOB COMPLETION. ANY WORK, MATERIAL, OR EQUIPMENT FOUND TO BE FAULTY DURING THAT PERIOD SHALL BE CORRECTED AT ONCE, UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. 9.ALL CONDUIT ONLY (C.O.) SHALL HAVE A PULL WIRE OR ROPE, AND TRUE TAPE. 10.PROVIDE THE OWNER WITH ONE SET OF COMPLETE DIMENSIONS AND CIRCUITS, WITHIN 10 WORKING DAYS OF PROJECT COMPLETION. ELECTRICAL "AS BUILT" DRAWINGS, SHOWING ACTUAL LOCATION OF CONDUITS. 11.ALL BROCHURES, OPERATING MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE TURNED OVER TO PROJECT MANAGER AT JOB COMPLETION. 12.USE T-TAP CONNECTIONS ON ALL MULTI-CIRCUITS WITH COMMON NEUTRAL CONDUCTOR FOR LIGHTING FIXTURE. ALL CONDUCTORS SHALL BE COPPER. 13.THE EXTERIOR GROUND RING SHALL BE TESTED PER CCI SPECIFICATIONS AND SHALL HAVE A RESISTANCE TO EARTH OF 5 OHMS OR LESS. IF NOT NOTIFY ENGINEER. 14.ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING NOT LESS THAN THE MAXIMUM SHORT =CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED, AND A MINIMUM OF 10,000 A.I.C. 15.THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALL APPLICABLE CODES. 16.PATCH, REPAIR, AND PAINT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE ELECTRICAL WORK. 17.IN DRILLING HOLES INTO CONCRETE (WHETHER FOR FASTENING OR ANCHORING PURPOSES OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT RUNS, PIPE RUNS, ETC.) IT MUST BE CLEARLY UNDERSTOOD THAT TENDONS AND RE-BARS WILL NOT BE DRILLED INTO, CUT, OR DAMAGED UNDER ANY CIRCUMSTANCES. 18.LOCATION OF TENDONS AN RE-BARS ARE NOT DEFINITELY KNOWN AND THEREFORE MUST BE SEARCHED FOR BY APPROPRIATE METHODS AND EQUIPMENT VIA X-RAY, OR OTHER DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING STEEL TENDONS. 19.PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE STOPPED IN ACCORDANCE WITH APPLICABLE LOCAL BUILDING CODES. USING U.L. RATED MATERIALS. 20.ELECTRICAL CONTRACTOR IS TO COORDINATE WITH UTILITY COMPANY FOR CONNECTION OF TEMPORARY AND PERMANENT POWER TO THE SITE. THE TEMPORARY POWER AND ALL HOOK-UP COSTS SHALL BE PAID BY THE CONTRACTOR. 21.ELECTRICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND/OR CATALOG CUT-SHEETS ON ALL NON-SPECIFIED ORIGINAL MATERIALS AND EQUIPMENT, TO PROJECT MANAGER PRIOR TO COMMENCEMENT OF THE WORK. 22.UPON COMPLETION OF WORK, CONDUCT CONTINUITY AND SHORT CIRCUIT, AS WELL AS, GROUNDING TEST, GROUNDING TEST SHALL BE PREFORMED BY INDEPENDENT TESTING AGENCY, WITH WRITTEN REPORT SUBMITTED TO THE PROJECT MANAGER FOR REVIEW AND APPROVAL. 23.CLEAN PREMISES DAILY OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK PREMISES IN A COMPLETE AND UNDAMAGED CONDITION. 24.ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WITH POLYSEAM SEALANT. 25.ALL #2 TINNED BARE COPPER DOWNLEADS TO BE PROTECTED BY 1/2" P.V.C. PIPE AND SECURED. 26.COMPRESSION FITTINGS TO BE USED ON ALL CONDUITS (NO SET SCREWS). 27.ALL #6 STRANDED COPPER WITH GREEN INSULATION TO BE ATTACHED WITH CRIMPED DOUBLE LUG, ATTACHED WITH NUTS, BOLTS AND STAR WASHERS TYPICAL AND NO-OX GREASE BETWEEN LUG AND BUS BAR. 28.ALL ABOVE GROUND CONDUIT SHALL BE RIGID GALVANIZED CONDUIT WITH WEATHERPROOF FITTINGS. GROUNDING 1.ALL METALLIC PARTS OF ELECTRICAL EQUIPMENT WHICH DO NOT CARRY CURRENT SHALL BE GROUNDED IN ACCORDANCE WITH THE REQUIREMENTS OF THE BUILDING MANUFACTURER, T-MOBILE GROUNDING AND BONDING STANDARDS, AND THE NATIONAL ELECTRICAL CODE. 2.PROVIDE ELECTRICAL GROUNDING AND BONDING SYSTEM INDICATED WITH ASSEMBLY OF MATERIALS, INCLUDING GROUNDING ELECTRODES, BONDING JUMPERS AND ADDITIONAL ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION. 3.ALL GROUNDING CONDUCTORS SHALL PROVIDE A STRAIGHT DOWNWARD PATH TO GROUND WITH GRADUAL BEND AS REQUIRED. GROUNDING CONDUCTORS SHALL NOT BE LOOPED OR SHARPLY BENT. ROUTE GROUNDING CONNECTIONS AND CONDUCTORS TO GROUND IN THE SHORTEST AND STRAIGHTEST PATHS POSSIBLE TO MINIMIZE TRANSIENT VOLTAGE RISES. BUILDINGS AND/OR NEW TOWERS GREATER THAN 75 FEET IN HEIGHT AND WHERE THE MAIN 4.GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUND RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN #2 AWG COPPER. ROOFTOP GROUND RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). 5.TIGHTEN GROUNDING AND BONDING CONNECTORS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALUES FOR CONNECTORS AND BOLTS. WHERE MANUFACTURER'S TORQUING REQUIREMENTS ARE NOT AVAILABLE, TIGHTEN CONNECTIONS TO COMPLY WITH TIGHTENING TORQUE VALUES SPECIFIED IN UL TO ASSURE PERMANENT AND EFFECTIVE GROUNDING. CONTRACTOR SHALL VERIFY THE LOCATIONS OF GROUNDING TIE-IN-POINTS TO THE EXISTING 6.ALL UNDERGROUND GROUNDING CONNECTIONS SHALL BE MADE BY THE GROUNDING SYSTEM. EXOTHERMIC WELD PROCESS AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 7.ALL GROUNDING CONNECTIONS SHALL BE INSPECTED FOR TIGHTNESS. EXOTHERMIC WELDED CONNECTIONS SHALL BE APPROVED BY THE INSPECTOR HAVING JURISDICTION BEFORE BEING PERMANENTLY CONCEALED. 8.APPLY CORROSION-RESISTANCE FINISH TO FIELD CONNECTIONS AND PLACES WHERE FACTORY APPLIED PROTECTIVE COATINGS HAVE BEEN DESTROYED. 9.A SEPARATE, CONTINUOUS, INSULATED EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL FEEDER AND BRANCH CIRCUITS. 10.BOND ALL INSULATED GROUNDING BUSHINGS WITH A BARE 6 AWG GROUNDING CONDUCTOR TO A GROUND BUS. 11.DIRECT BURIED GROUNDING CONDUCTORS SHALL BE INSTALLED AT A NOMINAL DEPTH OF 36" MINIMUM BELOW GRADE, OR 6" BELOW THE FROST LINE, USE THE GREATER OF THE TWO DISTANCES. 12.ALL GROUNDING CONDUCTORS EMBEDDED IN OR PENETRATING CONCRETE SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT. 13.THE INSTALLATION OF CHEMICAL ELECTROLYTIC GROUNDING SYSTEM IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. REMOVE SEALING TAPE FROM LEACHING AND BREATHER HOLES. INSTALL PROTECTIVE BOX FLUSH WITH GRADE. 14.DRIVE GROUND RODS UNTIL TOPS ARE A MINIMUM DISTANCE OF 36" DEPTH OR 6" BELOW FROST LINE, USING THE GREATER OF THE TWO DISTANCES. 15.IF COAX ON THE ICE BRIDGE IS MORE THAN 6 FT. FROM THE GROUND BAR AT THE BASE OF THE TOWER, A SECOND GROUND BAR WILL BE NEEDED AT THE END OF THE ICE BRIDGE, TO GROUND THE COAX CABLE GROUNDING KITS AND IN-LINE ARRESTORS 16.CONTRACTOR SHALL REPAIR, AND/OR REPLACE, EXISTING GROUNDING SYSTEM COMPONENTS DAMAGED DURING CONSTRUCTION AT THE CONTRACTORS EXPENSE. Sheet Number: Sheet Title: Description:Rev:Date:By: DRAWN BY:CHK BY:APV BY: SITE NAME: SITE ID: PROJECT INFORMATION: LICENSURE NO: PLANS PREPARED BY: 18400 EAST 22ND AVE. AURORA, CO 80216 ALL SCALES ARE SET FOR 24"x36" SHEET 3980 QUEBEC STREET DENVER, CO 80207 WYCOFIELDSERVICES.COM here quality still counts.