Loading...
HomeMy WebLinkAboutPZ Staff Presentation_0917_401 W FrancisSpecial review for replacement of nonconforming structure 401 W. Francis St. Sophie Varga, Zoning Administrator September 17, 2024 “Within the Zone Districts established by this Title, there exist uses of land, buildings and structures that were lawfully established before this Title was adopted or amended which would be in violation of the terms and requirements of this Title. The purpose of this Chapter is to regulate and limit the continued existence of those uses, buildings and structures that do not conform to the provisions of this Title as amended. It is the intent of this Chapter to permit nonconformities to continue, but not to allow nonconformities to be enlarged or expanded. The provisions of this Chapter are designed to curtail substantial investment in nonconformities in order to preserve the integrity of the zone districts and the other provisions of this Title but should not be construed as an abatement provision.” Nonconformities Chapter- Purpose •401 W. Francis St. •Single Family Residence built in the 1980s •R-6 Zone District •Code changed, structure is now over allowable floor area and projects into the setback •Propose to replace nonconforming floor area and small portions of structure in the setback Background and Summary Sec. 26.430.040.a, Dimensional requirements.Whenever the dimensional requirements of a proposed development are subject to special review, the development application shall only be approved if the following conditions are met. (1) The mass, height, density, configuration, amount of open space, landscaping and setbacks of the proposed development are designed in a manner which is compatible with or enhances the character of surrounding land uses and is consistent with the purposes of the underlying zone district. Review Standards for Special Review Sec. 26.430.040.b, Replacement of Nonconforming Structures. (3) No dimensional variations are increased, and the replacement structure represents the minimum variance that will make possible the reasonable use of the property; and (4) Literal enforcement of the dimensional provisions of the zone district would cause unnecessary hardship upon the owner by prohibiting reasonable use of the property. Review Standards for Special Review “For existing single-family, duplex and multi-family residential structures that encroach into the setback and propose energy efficiency of fire protection upgrades on the exterior of the structure, a maximum of eight (8) inches of all exterior veneer such as brick, stone or other exterior treatments, including fire proofing, exterior insulation, and any methods of attachment for insulation, may be added to the wall assembly without being considered a nonconformity and triggering compliance with Chapter 26.430, Nonconformities. In any instance where the addition of exterior improvements result in a setback of five (5) feet or less, the Community Development Director shall evaluate site context to ensure the improvements are appropriate and compliant with building codes.” Measuring Setbacks (Sec. 26.575.020.e.1.c) m a d W - G I■ II�_IC III � 11111 CITY OFASPEN 3 10'-0" SETBACK 9'-3 7116" PROPOSED �1-4 181/256" 6'-7 751256 " EXISTING 9'-811/16" i EXISTING Dimensional Limitations Table Dimensional Limitation Allowable Existing Proposed Floor Area 3,237 sq. ft.3,800 sq. ft.3,710 sq. ft. Minimum Front Yard Setback 10’9’4”8’11” Minimum Side Yard Setback West: 5’ East: 10’ West: 5’3” East: 6’7” West: 4’9” East: 9’9” Combined Side Yard Setback 15’11’10”14’ Staff recommends that the Planning and Zoning Commission approve the request to replace nonconforming structure at 401 W. Francis St.