Loading...
HomeMy WebLinkAboutApproved Drawings.523 W Smuggler StWE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N T1.0 PROJECT DATA SHEET #TITLE T1.0 PROJECT DATA T1.1 GENERAL NOTES ARCHITECTURAL: SP1.0 SITE PLAN & EXISTING/DEMO SITE PLAN CC1.0 CODE COMPLIANCE D1.0 GROUND LEVEL EXISTING/DEMO FLOOR PLANS D1.1 SECOND LEVEL EXISTING/DEMO FLOOR PLANS D2.0 EXISTING & DEMO BUILDING ELEVATIONS D2.1 EXISTING & DEMO BUILDING ELEVATIONS A1.0 GROUND LEVEL FLOOR PLAN A1.1 SECOND LEVEL FLOOR PLAN A1.2 GROUND LEVEL REFLECTED CEILING PLAN A1.3 SECOND LEVEL REFLECTED CEILING PLAN A2.0 BUILDING ELEVATIONS A2.1 BUILDING ELEVATIONS A3.0 SCHEDULES & STAIR DETAILS A4.0 SPECIFICATIONS STRUCTURAL: #TBD SHEET NAME TBD WEISS RESIDENCE 523 WEST SMUGGLER STREET ASPEN, COLORADO 81611 JURISDICTION JURISDICTION ENTITY ADDRESS PHONE NUMBER BUILDING CODE: 2015 INTERNATIONAL RESIDENTIAL CODE (2015 IRC) 2015 INTERNATIONAL ENERGY CONSERVATION CODE (2015 IECC) PROJECT CONTACTS: N SCALE: NOT TO SCALE VICINITY MAP PROJECT DATA: INTERIOR MINER'S CABIN 1. REPLACE EXISTING INTERIOR GAS APPLIANCE FIREPLACE AND SURROUND UTILIZING THE EXISTING VENT PATH TO THE EXISTING CHIMNEY. NO CHANGES TO THE EXISTING EXTERIOR CHIMNEY ARE PROPOSED. 2002 ADDITION 1. DEMOLITION & REMOVAL OF EXISTING KITCHEN TO BECOME DINING ROOM. ADD NEW CASEWORK. 2. DEMOLITION & REMOVAL OF EXISTING GAS FIREPLACE ADJACENT STAIR. 3. DEMOLITION & REMOVAL OF EXISTING MASTER BATHROOM AND CLOSET FIXTURES & FINISHES. 4. DEMOLITION & REMOVAL OF INACTIVE HVAC EQUIPMENT ABOVE EXISTING MASTER BATHROOM & ENTRY CLOSET. 5. CONSTRUCTION OF NEW MASTER SUITE INTERIOR WALLS, LIGHTING AND PLUMBING FIXTURES. 6. CONSTRUCTION OF NEW KITCHEN IN NEW LOCATION WITH CABINETRY & APPLIANCES. EXTERIOR MINER'S CABIN 1. NO CHANGES TO EXISTING STRUCTURE ARE PROPOSED 2002 ADDITION 1. NORTH ELEVATION -DEMOLITION & REMOVAL OF PATIO DOOR @ MASTER BEDROOM AND EXISTING LIVING ROOM, INFILL WITH FRAMING, PROVIDE INSULATION, PATCH SIDING TO MATCH. -DEMOLITION & REMOVAL OF WINDOWS @ MASTER SUITE AND EXISTING LIVING ROOM, INFILL WITH FRAMING, PROVIDE INSULATION, PATCH SIDING TO MATCH. -REMOVAL OF EXISTING WALL MOUNTED LIGHTING -CONSTRUCTION OF NEW WINDOW AT MASTER BEDROOM. -CONSTRUCTION OF NEW SLIDING DOOR AT NEW KITCHEN. -CONSTRUCTION OF NEW WALL MOUNTED DOWN LIGHTING. 2. EAST ELEVATION -DEMOLITION AND REMOVAL OF WINDOW AT DINING ROOM, INFILL WITH FRAMING, PROVIDE INSULATION, PATCH SIDING TO MATCH. -REMOVAL OF EXISTING WALL MOUNTED LIGHTING. -CONSTRUCTION OF NEW WINDOWS AT NEW DINING ROOM AND MASTER BEDROOM. -CONSTRUCTION OF NEW OUTDOOR KITCHEN WITH NATURAL GAS GRILL ADJACENT TO NEW DINING ROOM 3. SOUTH ELEVATION -DEMOLITION & REMOVAL OF WINDOW @ DINING ROOM & MASTER BEDROOM, INFILL WITH FRAMING, PROVIDE INSULATION, PATCH SIDING TO MATCH. -REMOVAL OF EXISTING WALL MOUNTED LIGHTING. -CONSTRUCTION OF NEW WINDOW @ DINING ROOM AND MASTER BEDROOM. -CONSTRUCTION OF NEW WALL MOUNTED DOWN LIGHTING. 4. WEST ELEVATION -DEMOLITION & REMOVAL OF WINDOWS @ EXISTING KITCHEN & LIVING ROOM. INFILL WITH FRAMING, PROVIDE INSULATION, PATCH SIDING TO MATCH. -CONSTRUCTION OF NEW WINDOWS @ NEW KITCHEN -CONSTRUCTION OF OUTDOOR KITCHEN AT EAST SIDE OF 2002 ADDITION. PROJECT SCOPE: COMPLIANCE METHOD 1: PRESCRIPTIVE / UA TRADEOFF (2015 IRC SECTION N1101.13 ENERGY COMPLIANCE: LEVEL OF ALTERATION: LEVEL 1 ALTERATION (2015 IEBC CHAPTER 5) PROPERTY TYPE: SINGLE FAMILY RESIDENCE FIRE PROTECTION:NON-SPRINKLERED CONSTRUCTION TYPE: VB OCCUPANCY: R3 BUILDING HEIGHT:EXISTING TO REMAIN GROSS FLOOR AREA:EXISTING TO REMAIN CODE ANALYSIS: SUBDIVISION: HISTORIC LANDMARK AT 513 W SMUGGLER ST LOT: A LEGAL DESCRIPTION: 523 WEST SMUGGLER STREET ASPEN, COLORADO 81611 PARCEL ID: 273512499001 PROJECT ADDRESS:SHEET INDEX: OWNER: SOL H AND FAITH E WEISS 1706 RITTENHOUSE SQ #1401 PHILADELPHIA, PA 19103 (215) 285 9143 SWEISS@ANAPOLWEISS.COM DESIGNER/ARCHITECT: BG ARCHITECTURE & DESIGN, LLC 111H ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 T. (970) 948 6709 CONTACT: BARRY GEREB BARRY.GEREB@BGADASPEN.COM STRUCTURAL ENGINEER: SILVER TOWN STRUCTURES 307N ASPEN AIRPORT BUSINESS CENTER ASPEN, CO 81611 T. (970) 300 1003 CONTACT: HEIN BRUTSAERT HEIN3@SOPRIS.NET CONTRACTOR: BUILD WEST CUSTOM HOMES PO BOX 9085 ASPEN, CO 81612 (970) 618 6823 CONTACT: JACOB DOWN JD@BUILDWEST.COM 523 WEST SMUGGLER MAIN STR E E T E A S T C O O P E R A V E N U E HIGH W A Y 8 2 SMUGGL E R S T R E E T NO R T H 5 T H S T R E E T WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N T1.1 GENERAL NOTES & LEGEND D01 A 1 A3.0 1 A3.0 1 A3.0 1 A5.0 1 A2.0 4 1 2 3 CONCRETE CONCRETE MASONRY STONE FRAME WALL TILE STEEL ALUMINUM OR SHEET METAL BATT INSULATION GYP. WALL BOARD/ STUCCO /PLASTER PLYWOOD SOIL/ COMPLACTED FILL ROCK/ NON-COMPACTED FILL/ GRAVEL SAND/ GWB/ PLASTER FINISHED WOOD ROUGH FRAMING OR ROUGH SAWN TRIM WOOD BLOCKING GLU-LAM WOOD PARTICAL BOARD OR WOOD FIBER BOARD RIGID INSULATION CARPET 1 BUILDING SECTION CUT WALL SECTION CUT DETAIL DETAIL CUT EXTERIOR ELEVATION ROOM NUMBER DOOR MARK GRID REFERENCE LINE SPOT ELEVATION DRAWING REVISION INTERIOR ELEVATION WINDOW MARK SYMBOL LEGEND MATERIALS LEGEND ABBREVIATIONS AAD ATTIC ACCESS DOOR ADD ADDENDUM ADJ ADJACENT AFF ABOVE FINISH FLOOR AGG AGGREGATE ALT ALTERNATE AOR AREA OF REFUGE ARCH ARCHITECTURAL ASS'Y ASSEMBLY B/O BOTTOM OF BD BOARD BTW BETWEEN BLDG BUILDING BM BEAM BRG BEARING BS BOTH SIDES CAB CABINET CER CERAMIC CJ CONSTRUCTION JOINT CL CENTERLINE CLST CLOSET CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS D DRYER DET DETAIL DIA DIAMETER DIM DIMESION DN DOWN DP DAMPPROOFING DR DRAIN DS DOWNSPOUT DW DISHWASHER DWG DRAWING EA EACH EJ EXPANSION JOINT EL ELEVATION EQ EQUAL EXIST EXISTING EXT EXTERIOR FFA FINISH FLOOR FDN FOUNDATION FE CABT FIRE EXTINGUISHER FIN FINISH FL FLOOR FOC FACE OF CONCRETE FOS FACE OF STUD FR FIREPROOFING FTG FOOTING GA GAUGE GALV GALVINIZED GC GENERAL CONTRACTOR GLB GLU-LAM BEAM GR GRADE GWB GYPSUM WALLBOARD GYP GYPSUM H.T.A. HEAVY TIMBER HD HEAD HDW HARDWARE HOR HORIZONTAL HT HEIGHT HVAC HEATING, VENTILATING, AND COOLING HWY HIGHWAY IBC INTERNATIONAL BUILDING CODE ICP INTEGRATED COLOR PLASTER ID INSIDE DIAMETER IE THAT IS INT INTERIOR INS INSULATION IRC INTERNATIONAL RESIDENTIAL CODE JT JOINT LAM LAMINATE LAV LAVATORY LH LEFT HAND LHR LEFT HAND REVERSE MAX MAXIMUM MC MEDICINE CABINET MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MO MASONRY OPENING MTL MATERIAL NA NOT APPLICABLE NIC NOT IN CONTRACT NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMTER OPG OPENING OPH OPPOSITE HAND OPP OPPOSITE PERF PERFORATED PFSM PREFINISHED SHEET METAL PL PLATE PLY PLYWOOD PROD PRODUCT PROJ PROJECT PROP PROPERTY R RADIUS / RISER REF REFER REFR REEFRIGERATOR REQ'D REQUIRED RH RIGHT HAND RHR RIGHT HAND REVERSE RHSM ROUND HEAD SHEET METAL RM ROOM RO ROUGH OPENING S.T.D.A. SLOPE TO DRAIN SAN SANITARY SECT SECTION SEW SEWER SG SAFETY GLAZING SHLV SHELVES SHT SHEET SIM SIMILAR SM/CO SMOKE / CO DETECTOR SPEC SPECIFICATION SQ SQAURE STC SOUND TRANSMISSION CLASS STL STEEL STRUCT STRUCTUR(AL) SUB SUBSTITUTE SUPPL SUPPLEMENT(AL) SUSP SUSPEND(ED) T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE T/O TOP OF TEL TELEPHONE TEMP TEMPERED THK THICK TPH TOILET PAPER HOLDER TS TUBE STEEL TV TELEVISION TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE UBC UNIFORM BUILDING CODE UG UNDERGROUND UNFIN UNFINISHED USG UNITED STATES GAUGE V.I.F.A. VERIFY IN FIELD VAR VARIABLE VENT VENTILATE(D) VG VERTICAL GRAIN W WASHER WD WOOD EL. 100'-0" MAIN LEVEL GENERAL NOTES CODE NOTES A9.0 1. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, AND SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF CRAFTSMANSHIP BY JOURNEYMEN OF THE APPROPRIATE TRADES. 2. ALL DRAWINGS REPRESENTED, AND DIMENSIONS SHOWN, ARE TO BE FACE OF STUD AT WALL, FACE OF CONCRETE, OR CENTER LINE OF COLUMNS UNLESS NOTED OTHERWISE. 3. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS. DIMENSIONS NOTED “N.T.S.” DENOTE NOT TO SCALE. 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DESCRIPTIONS, EXISTING AND PROPOSED, AND JOB SITE CONDITIONS, PRIOR TO STARTING WORK. 5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. THE ARCHITECT MAY PROVIDE SUPPLEMENTAL INFORMATION REGARDING DESIGN INTENT WHERE ACCOMMODATIONS FOR EXISTING CONDITIONS, OR WHERE SUFFICIENT INFORMATION, IS ABSENT FROM THE THESE DOCUMENTS. 6. SHOULD A DISCREPANCY OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS, CONSULT THE ARCHITECT IMMEDIATELY AND PRIOR TO COMMENCING WORK. 7. CONTRACTOR WILL ASSUME RESPONSIBILITY FOR ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE BIDDING PROCESS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT FOR ANY CLARIFICATIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT FOR PRIOR APPROVAL BEFORE EXCLUDING ANY ITEMS OR PRODUCTS FROM THEIR BID. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED COMPLETED TO THE OWNER. 9 ANY QUESTIONS REGARDING THE INTENT OF THE DRAWINGS OR SPECIFICATIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO ORDERING MATERIALS OR PROCEEDING WITH THE RELATED WORK. 10. THESE DOCUMENTS REPRESENT THE COMPLETED PROJECT. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION. 11. EACH MISCELLANEOUS ITEM OF CUTTING, PATCHING, OR FITTING IS NOT NECESSARY INDIVIDUALLY DESCRIBED IN THESE DOCUMENTS. NO SPECIFIC DESCRIPTION OF CUTTING, PATCHING, OR FITTING REQUIRED TO PROPERLY ACCOMMODATE THE SCOPE OF WORK SHALL RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY TO PERFORM SUCH WORK AS MAY BE REQUIRED TO COMPLETE THE PROJECT. 12. ALL ITEMS ARE NEW UNLESS CALLED OUT AS “EXISTING”. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION. 14. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, AND OTHER DISCIPLINE DRAWINGS, SPECIFICATIONS, AS WELL AS EXISTING CONDITIONS. 15. ALL WORK SHALL BE ERECTED PLUMB AND TRUE-TO-LINE IN ACCORDANCE WITH BEST PRACTICES OF THE TRADE, MANUFACTURER'S RECOMMENDATIONS FOR THE PARTICULAR PRODUCT, AND IN ACCORDANCE WITH THE SPECIFICATIONS. 16. WHERE INSTALLED WORK IS DAMAGED OR EXISTING FINISHES ARE DISTURBED DURING CONSTRUCTIONS, SUCH AREAS SHALL BE BE REFINISHED TO MATCH THE AREA PRIOR TO BEING DAMAGED OR DISTURBED. 17. CONTRACTOR TO PROVIDE THERMAL INSULATION AT ALL EXTERIOR WALLS, FLOORS AND CEILINGS. PROVIDE FIRE SEPARATIONS AS REQUIRED. 18. CONTRACTOR SHALL TAKE FULL RESPONSIBILITY TO FLASH, SEAL, AND WATERPROOF THE ENTIRE BUILDING ENCLOSURE. 19. CONTRACTOR TO VERIFY AND PROVIDE ALL MECHANICAL AND PASSIVE VENTING AND FRESH AIR SUPPLY AS REQUIRED. 20. CONTRACTOR SHALL DO ALL CUTTING, FITTING, PATCHING, EXCAVATION, OR OTHER REQUIRED TASK OF THEIR WORK THAT MAY BE REQUIRED FOR ALL SUBCONTRACTORS TO BE ABLE TO PERFORM THEIR WORK. THIS CUTTING, FITTING, PATCHING, EXCAVATION, OR OTHER REQUIRED TASK SHALL NOT ENDANGER OTHER WORK OR STRUCTURES. ALL PATCHING OR REPAIRING SHALL BE DONE WITH LIKE MATERIALS SO THAT SURFACES REPLACED WILL MATCH SURROUNDING SURFACES UPON COMPLETION. 21. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN AND ORDERLY CONDITION. EACH SUBCONTRACTOR, IMMEDIATELY UPON COMPLETION OF EACH PHASE OF WORK, SHALL REMOVE ALL DEBRIS AS A RESULT OF THEIR WORK. 22. NO PORTION OF WORK REQUIRING SHOP DRAWINGS OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SHOP DRAWING OR SAMPLE HAS BEEN REVIEWED BY THE ARCHITECT AND/OR THE STRUCTURAL ENGINEER. 23. THE LOCAL GOVERNMENT AGENCIES SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS A NEED OF INSPECTION AS REQUIRED BY THE APPLICABLE CODE OR BY ANY LOCAL CODE OR ORDINANCE. 24. ANY CHANGES TO THESE DOCUMENTS MADE BY ANYONE EXCEPT THE ARCHITECT ARE THE RESPONSIBILITY OF THE PERSON MAKING, OR AUTHORIZING, THE CHANGE. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR CHANGES OR DETAILS MADE BY OTHERS. 25. THE PRESENCE OF THE ARCHITECT ON THE JOB SITE DOES NOT IMPLY CONCURRENCE OR APPROVAL OF THE WORK. THE CONTRACTOR SHALL CALL SPECIFIC ITEMS TO THE ATTENTION OF THE ARCHITECT TO OBTAIN THE ARCHITECT'S REVIEW. 26. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT, THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, GENERAL PROVISIONS, DRAWINGS, SPECIFICATIONS, ADDENDA, AND SUPPLEMENTARY DOCUMENTS AS ISSUED BY THE ARCHITECT IN ACCORDANCE WITH THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THE CONTRACT. DRAWINGS AND SPECIFICATIONS ARE COOPERATIVE AND CONTINUOUS. WORK INDICATED OR REASONABLY IMPLIED IN EITHER SHALL BE PROVIDED AS THOUGH FULLY COVERED BY BOTH. ANY DISCREPANCY BETWEEN THE CONTRACT DOCUMENTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. 1.APPLICABLE BUILDING CODES: -2015 INTERNATIONAL RESIDENTIAL CODE (2015 IRC) -2015 INTERNATIONAL EXISTING BUILDING CODE (2015 IEBC) -2015 INTERNATIONAL PLUMBING CODE (2015 IPC) -2015 INTERNATIONAL MECHANICAL CODE (2015 IMC) -2015 INTERNATIONAL FUEL & GAS CODE (2015 IGFC) -2015 INTERNATIONAL ENERGY CONSERVATION CODE (2015 IECC) LEVEL 2 ALTERCATION: ALL WORK TO BE PERFORMED SHALL CONFORM WITH CURRENTLY ADOPTED CODES. XXX 1 20.5 SF 2 39.7 SF 3 12.3 SF 4 8.1 SF 5 7.3 SF 6 19.6 SF 7 68.9 SF 8 104.6 SF 9 10.5 SF 10 48.9 SF 11 14.5 SF 12 45.5 SF 13 60.2 SF 14 20.8 SF 15 8.2 SF 16 31.8 SF 17 60.5 SF TOTAL 581.8 SF PROPOSED DEMO AREA DEMO AREA 1 2 3 4 5 6 7 12 8 10 11 13 14 15 16 17 9 20.5 SF 39.7 SF 12.3 SF 8.1 SF 7.3 SF 19.6 SF 68.9 SF 45.5 SF 104.6 SF 48.9 SF 14.5 SF 60.2 SF 20.8 SF 8.2 SF 31.8 SF 60.5 SF 10.5 SF bg AR C H I T E C T U R E & D E S I G N 2/5/21 CC1.0 CODE COMPLIANCE LOT A LOT B LOT A LOT B EXISTING SITE PLAN 1/8" = 1'-0" 1 SP1.0 PROPOSED SITE PLAN 1/8" = 1'-0" 2 SP1.0 AREA OF PROPOSED WORK: 8'-0" X 2'-9" OUTDOOR KITCHEN W/ NATURAL GAS GRILL CONCRETE PAVER PATIO & WALK CONCRETE PAVER PATIO CO N C R E T E P A V E R W A L K WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N SP1.0 SITE PLAN ABCDEFG 1 2 3 4 5 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 1 D2.0 2 D2.0 3 D2.0 1 D2.1 2 D2.1 3 D2.1 OVERHANG ABOVE OVERHANG ABOVE DN 1R LINE OF HEADER ABOVE LINE OF HEADER ABOVE GARAGE STAIR EGRESS WELL OFFICE FRONT PORCH MINERS CABIN POWDER ENTRY KITCHEN DINING ROOM HALLMUDROOM EGRESS WELL 1 1 1 11 1 1 2 3 3 3 134 48 4 4 4 6 5 13 4 4 5 6 3 3 2 2 27 7 7 4 10 4 4 12 12 9 3 13 2 14 15 1616 REMOVE EXISTING WINDOW REMOVE EXISTING DOOR REMOVE EXISTING WALL AT PROPOSED WINDOW/DOOR OPENING REMOVE EXISTING GAS APPLIANCE: FIREPLACE REMOVE EXISTING FIREPLACE SURROUND REMOVE EXISTING PLUMBING FIXTURE 1 2 3 4 5 6 7 FLOOR CEILING PLAN DEMOLITION NOTES REMOVE EXITING CABINET / BUILD-IN FURNITURE REMOVE EXISTING GAS APPLIANCE: RANGE, OVEN AND HOOD8 REMOVE EXISTING CEILING FINISH & FRAMING AT PROPOSED ACCESS PANEL 9 REMOVE EXISTING ACCESS PANEL10 REMOVE EXISTING SHOWER ENCLOSURE11 REMOVE EXISTING EXTERIOR FINISH MATERIAL BELOW 36" AFF12 REMOVE EXISTING WALL, PATCH & REPAIR DRYWALL13 EXISTING SNOWMELT CONTROL PAD TO BE RELOCATED14 EXISTING AWNING & CONTROLS TO BE REMOVED15 EXISTING FLAGSTONE PATIO & WALK TO BE REMOVED16 ALL LIGHT FIXTURES IN THE MINER'S CABIN, OFFICE, POWDER, ENTRY, KITCHEN, DINING, HALL MUDROOM AND EXTERIOR SHALL BE REMOVED UNLESS NOTED OTHERWISE, RE: LIGHTING SCHEDULE & REFLECTED CEILING PLANS. ALL OTHER INTERIOR LIGHTING SHALL BE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. ALL EXTERIOR LIGHT FIXTURES SHALL BE REMOVED UNLESS NOTED OTHERWISE, RE: LIGHTING SCHEDULE & REFLECTED CEILING PLANS GENERAL DEMOLITION NOTES WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N D1.0 GROUND LEVEL DEMOLITION PLAN GROUND LEVEL EXISTING/DEMOLITION PLAN 1/4" = 1'-0" 1 D1.0 DE 1 2 3 4 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 2 D2.0 3 D2.0 2 D2.1 3 D2.1 MASTER BEDROOM MA S T E R BA T H R O O M MASTER CLOSET VESTIBULE MASTER ROOFDECK 1 1 1 ABOVE 1 11 1 1 2 2 2 2 3 3 13 13 13 13 3 3 4 4 9 10 4 7 7 7 7 7 11 3 REMOVE EXISTING WINDOW REMOVE EXISTING DOOR REMOVE EXISTING WALL AT PROPOSED WINDOW/DOOR OPENING REMOVE EXISTING GAS APPLIANCE: FIREPLACE REMOVE EXISTING FIREPLACE SURROUND REMOVE EXISTING PLUMBING FIXTURE 1 2 3 4 5 6 7 FLOOR CEILING PLAN DEMOLITION NOTES REMOVE EXITING CABINET / BUILD-IN FURNITURE REMOVE EXISTING GAS APPLIANCE: RANGE, OVEN AND HOOD8 REMOVE EXISTING CEILING FINISH & FRAMING AT PROPOSED ACCESS PANEL 9 REMOVE EXISTING ACCESS PANEL10 REMOVE EXISTING SHOWER ENCLOSURE11 REMOVE EXISTING EXTERIOR FINISH MATERIAL BELOW 36" AFF12 REMOVE EXISTING WALL, PATCH & REPAIR DRYWALL13 EXISTING SNOWMELT CONTROL PAD TO BE RELOCATED14 EXISTING AWNING & CONTROLS TO BE REMOVED15 EXISTING FLAGSTONE PATIO & WALK TO BE REMOVED16 ALL LIGHT FIXTURES IN THE MINER'S CABIN, OFFICE, POWDER, ENTRY, KITCHEN, DINING, HALL MUDROOM AND EXTERIOR SHALL BE REMOVED UNLESS NOTED OTHERWISE, RE: LIGHTING SCHEDULE & REFLECTED CEILING PLANS. ALL OTHER INTERIOR LIGHTING SHALL BE EXISTING TO REMAIN UNLESS NOTED OTHERWISE. ALL EXTERIOR LIGHT FIXTURES SHALL BE REMOVED UNLESS NOTED OTHERWISE, RE: LIGHTING SCHEDULE & REFLECTED CEILING PLANS GENERAL DEMOLITION NOTES WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N D1.1 UPPER LEVEL DEMOLITION PLAN SECOND LEVEL EXISTING/DEMOLITION PLAN 1/4" = 1'-0" 1 D1.1 1 2 3 4 5 6 7 2 3 4 5 7 8 9 10 11 AREA OF PROPOSED WORK INDICATED BY HATCH. RE: CC1.0 FOR DEMO CALCS AREA OF PROPOSED WORK INDICATED BY HATCH. RE: CC1.0 FOR DEMO CALCS AREA OF PROPOSED WORK BEYOND, INDICATED BY HATCH. RE: CC1.0 FOR DEMO CALCS NORTH EXISTING / DEMO ELEVATION EAST EXISTING / DEMO ELEVATION SECTION / NORTH ELEVATION ALONG GRID D 3 bg AR C H I T E C T U R E & D E S I G N 2/5/21 D2.0 EXISTING / DEMOLITION BUILDING ELEVATIONS 12 12 13 14 15 16 AREA OF PROPOSED WORK INDICATED BY HATCH. RE: CC1.0 FOR DEMO CALCS AREA OF PROPOSED WORK INDICATED BY HATCH. RE: CC1.0 FOR DEMO CALCS AREA OF PROPOSED WORK BEYOND, INDICATED BY HATCH. RE: CC1.0 FOR DEMO CALCS 17 WEST EXISTING / DEMO ELEVATION SOUTH EXISTING / DEMO ELEVATIONSECTION / SOUTH ELEVATION ALONG GRID E bg AR C H I T E C T U R E & D E S I G N 2/5/21 D2.1 EXISTING / DEMOLITION BUILDING ELEVATIONS ABCDEFG 1 2 3 4 5 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 1 A2.0 2 A2.0 3 A2.0 1 A2.1 2 A2.1 3 A2.1 DN 1R OVERHANG ABOVE OVERHANG ABOVE LINE OF HEADER ABOVE OFFICE FRONT PORCH MINERS CABIN PO W D E R ENTRY EGRESS WELL EGRESS WELL STAIR KITCHEN DINING HALL MUDROOMGARAGE BUILT-IN CABINET & SHELVES 4" MAX. OPENING NEW GUARD RAIL TO MATCH EXISTING, RE: 1/A3.0 EXTEND RISER & NOSING TO MATCH EXISTING MW D R A W E R & O V E N DW TRASH REF RANGE & DOWNDRAFT VENT PANTRY CLOSET BE N C H BENCH BENCH CONSOLE BAR STORAGE CABINET EXISTING GUARD TO REMAIN EXISTING GUARD TO REMAIN EXISTING FENCE & GATE W2 W3 S1 N3 E2 1 NATURAL GAS CONNECTION +36" AFF OUTDOOR KITCHEN W/ NATURAL GAS GRILL ON 4" CONCRETE PAD, FRAME AS REQUIRED BY GRILL MANUFACTURER 6'-9" 2' - 6 " 82.54SF OF AVAILABLE DECK FLOOR AREA REMAINS. OUTDOOR KITCHEN UTILIZES 21SF OF FLOOR AREA FOR A NET REMAINING DECK AREA OF 61.54SF OUTDOOR KITCHEN 1'-0" 2X WOOD FLAT FRAMING @ CHASE WALL 2'-2 1/2" FIELD VERIFY MILLWORK CLOSET 2X4 WOOD FURRING ON EXISTING FRAMING REGENCY - CITY SERIES P/N: CB60E GAS FIREPLACE, INSTALL PER MANUFACTURER'S INSTRUCTIONS, VENT THROUGH EXISTING CHIMNEY CONCRETE PAVER PATIO TO MATCH EAST PATIO, SKIP PAVERS AS REQUIRED TO AVOID EXISTING PLANTINGS & TREES CONCRETE PAVER WALK GENERAL NOTES: 1. INFILL REMOVED WINDOW, DOOR AND VENT LOCATIONS WITH WOOD FRAMING AND INSULATION TO MATCH EXISTING. PROVIDE SIDING & PAINT TO MATCH EXISTING. WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N A1.0 GROUND LEVEL FLOOR PLAN GROUND LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A1.0 DE 1 2 3 4 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E 2 A2.0 3 A2.0 2 A2.1 3 A2.1 MASTER BEDROOM MASTER CLOSET MASTER BATHROOM BALCONY MILL- WORK DRESSER MILLWORK CLOSET MILL- WORK DRESSER W1 W4 N1 N2 E1 S2 6'-0" 2'-10 1/2"1" 3" W5 GENERAL NOTES: 1. INFILL REMOVED WINDOW, DOOR AND VENT LOCATIONS WITH WOOD FRAMING AND INSULATION TO MATCH EXISTING. PROVIDE SIDING & PAINT TO MATCH EXISTING. WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N A1.1 SECOND LEVEL FLOOR PLAN SECOND LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A1.1 ABCDEFG 1 2 3 4 5 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E OFFICE FRONT PORCH MINERS CABIN POWDER EN T R Y EGRESS WELL STAIR KITCHEN DINING HALLMUDROOMGARAGE W2 W3 E2 MILLWORK CEILING @ 8'-6" AFF WITH MIN. 22"X30" REMOVABLE ACCESS PANEL L2L2 L2 L2 L1 L1 L1 L7 L10 L10 L1 L1 L1L1 L1 L1 L1L1 L6L6 D3 D3 D3 SM L3 L1 L3 L6 D F L1 L6 L6 OUTLET @ MILLWORK BASE OUTLET @ MILLWORK BASE L1 L1 L1L1 L2L2 L2L2 L7 L7 L7 L7 D3 D 3 D 3 D 3 D 3 OUTLET @ WINE COOLER L2 L4 L1 L1 L1 L1 L1 L1 L1 L1 L1 L7 L1 L1 L1 L1 D3 D3 OVENMW L1 L7 L7 L5 L7 L2 L2L2 +60"L7 L7 +72"+72"+72" D3 D3 D3 D3 OUTLET @ VENT OUTLET @ COOKTOP L6 IN COVE @ HEADER L7 D DW DISP ER1 ER1 L12 L12 D3 D3 L12 L12 ER2 ER3 ER3 WALL MOUNTED FIXTURE, EXISTING TO REMAIN WALL MOUNTED FIXTURE, EXISTING TO REMAIN NEW ELECTRIC AWNING OVER SLIDING DOOR ER1 WALL MOUNTED FIXTURE, EXISTING TO REMAIN SWITCH SWITCH WITH DIMMER CONTROL D 3 J SM 3-WAY SWITCH JAMB SWITCH SNOWMELT CONTROLS WP WATERPROOF ELECTRICAL OUTLET FLOOR ELECTRICAL OUTLET PS REMOTE POWER SUPPLY FOR LOW VOLTAGE FIXTURE. ELECTRICAL & LOW VOLTAGE NOTES ELECTRICAL LEGEND DUPLEX ELECTRICAL OUTLET QUAD ELECTRICAL OUTLET 220V ELECTRICAL OUTLET SWITCHED DUPLEX ELECTRICAL OUTLET ELECTRIC PANEL ELECTRIC METER HEIGHT ABOVE FINISHED FLOOR+42" CABLE TV OUTLET EXHAUST FAN ALL ELECTRICAL WORK SHALL COMPLY WITH PART VIII - ELECTRICAL OF THE 2015 INTERNATIONAL RESIDENTIAL CODE. IN THE EVENT OF CONFLICT BETWEEN THE DESIGN DOCUMENTS AND THE 2015 INTERNATIONAL RESIDENTIAL CODE, THE CODE SHALL PREVAIL. ELECTRICAL CONTRACTOR SHALL NOTIFY ARCHITECT OF AND CONDITIONS THAT DO NOT COMPLY WITH SUCH CODES. PROVIDE CODE MINIMUM ELECTRICAL OUTLETS THROUGHOUT. GENERAL AND ELECTRICAL CONTRACTORS TO REVIEW & CONFIRM ALL LIGHTING CONTROL, ELECTRICAL OUTLET, AND LOW VOLTAGE DEVICE BOX EXACT LOCATIONS WITH OWNERS VIA WALK-THRU MEETING PRIOR TO RUNNING ALL WIRING. PROVIDE CONCEALED POP-UP OUTLETS AT KITCHEN ISLAND LOCATIONS G.C. TO PROVIDE 2xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE AT NEW DATA TELEPHONE/LOCATIONS. (ALLOWS FOR PHONE, INTERCOM, WIRELESS ACCESS POINT, LAN, ETC.) G.C. TO PROVIDE 2xRG6 & 4xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE.AT NEW/FUTURE TELEVISION LOCATIONS ELECTRICAL FIXTURES AND DEVICES AS GRAPHICALLY INDICATED ON PLANS ARE INTENDED TO ILLUSTRATE LAYOUT ONLY. LAYOUT OF RECESSED AND SURFACE MOUNTED CEILING FIXTURES ARE GENERALLY CENTERED, ALIGNED, AND EQUALLY SPACED AS INDICATED ON PLANS. EXACT DIMENSIONS ARE AVAILABLE UPON REQUEST FROM LIGHTING DESIGNER. ARCHITECT AND OWNER TO REVIEW RECESSED FIXTURE LOCATIONS PRIOR TO CEILING FINISH INSTALLATION. PROVIDE SMOKE & CO DETECTORS THROUGHOUT THE RESIDENCE AS REQ'D BY LOCAL CODE OFFICIAL. PROVIDE ASSOCIATED SECURITY SYSTEM WITH MOTION SENSORS, GLASS BREAKS, WINDOW AND DOOR SENSORS, FREEZE AND FLOOD SENSORS, GAS DETECTORS, SYSTEM KEYPAD, ETC. LIGHTING AND OTHER NECESSARY LIGHTING FIXTURES TO BE SELECTED BY THE OWNER OR THE OWNER'S REPRESENTATIVE UNLESS NOTED OTHERWISE.COUNTER AIR SWITCH 1. 2. 3. 4. 5. 6. 7. SURFACE MONOPOINT LIGHT FIXTURE PENDANT LIGHT FIXTURE RECESSED CAN LIGHT FIXTURE ADJUSTABLE RECESSED CAN LIGHT FIXTURE LED 45° CHANNEL LIGHT FIXTURE WALL MOUNTED LINEAR ART LIGHT FITURE RECESSED LED LIGHT STRIP WALL MOUNTED DOWN LIGHT FIXTURE ADJUSTABLE RECESSED LED CAN LIGHTING FIXTURES (INTERIOR) L1 L2 L3 L4 L5 L6 QTY.HIGH EFFICACY YES SURFACE MOUNTED, ADJUSTABLE LED MONOPOINT DECORATIVE LED PENDANT DINING DECORATIVE LED PENDANT NO WALL MOUNTED LINEAR ART LED FIXTURE YES NO YES RECESSED / COVE LINEAR LED FIXTURE YES L7 YESLINEAR LED CABINET FIXTURE, HINGE SWITCH (SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.) L8 DECORATIVE LED PENDANT L9 DECORATIVE LED PENDANT NO DESCRIPTIONTAG NO WALL MOUNTED LED DOWN LIGHT, DARK SKY COMPLIANT, REFER TO EXTERIOR ELEVATIONS LIGHTING FIXTURES (EXTERIOR) L12 QTY.HIGH EFFICACY YES (SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.) DESCRIPTIONTAG L10 NOLED WALL LAMP L11 WET LOCATION ADJUSTABLE LED CAN YES 54 8 2 1 1 9 16 1 2 2 1 LIGHTING NOTES: 1. REFER TO PLANS & ELECTRICAL LEGEND FOR ADJUSTABLE/FIXED RECESSED CAN LIGHT FIXTURE LOCATIONS. 2. CONTRACTOR TO CONFIRM FIXTURE QUANTITIES PRIOR TO ORDERING. HIGH EFFICACY LIGHTING CALCULATION MINIMUM REQUIRED PERCENTAGE OF HIGH EFFICACY LIGHT FIXTURES: TOTAL PROVIDED LIGHT FIXTURES: TOTAL PROVIDED HIGH EFFICACY LIGHT FIXTURES: PERCENTAGE OF HIGH EFFICACY LIGHT FIXTURES: 50% 103 95 95/103 = 92.2% EXISTING TO REMAIN RECESSED LED CAN LIGHTER1 (E)2 5 EXISTING RELOCATED FLOOD LIGHTER2 YES1 EXISTING TO REMAIN WALL MOUNTED DOWN LIGHTER3 (E)3 NEW/MODIFIED FIXTURES ONLY WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N A1.2 GROUND LEVEL REFLECTED CEILING PLAN GROUND LEVEL REFLECTED CEILING PLAN 1/4" = 1'-0" 1 A1.2 DE 1 2 3 4 PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E MASTER BEDROOM MASTER CLOSET MASTER BATHROOM 10" WIDE DRYWALL SOFFIT ON WOOD FURRING @ 9'-6" AFF PROVIDE FLUSH GYP. BOARD ON WOOD FRAMING ACCESS PANEL WITH ALUMINUM REGLET TRIM, MINIMUM 22"X30" 8'-0" AFF EXISTING CEILING 5/8" GYP. BOARD ON WOOD FRAMING CEILING @ 8'-0 AFF INDICATED BY HATCH D3 D D D3 D F L7 L6 L1 L1L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L9 L9 L8 L11 L6 +60"+60" L1 L1 L6 F L1 L1 L1 L1 L12 ER3 WALL MOUNTED FIXTURE, EXISTING TO REMAIN D L7L7L7 D D SWITCH SWITCH WITH DIMMER CONTROL D 3 J SM 3-WAY SWITCH JAMB SWITCH SNOWMELT CONTROLS WP WATERPROOF ELECTRICAL OUTLET FLOOR ELECTRICAL OUTLET PS REMOTE POWER SUPPLY FOR LOW VOLTAGE FIXTURE. ELECTRICAL & LOW VOLTAGE NOTES ELECTRICAL LEGEND DUPLEX ELECTRICAL OUTLET QUAD ELECTRICAL OUTLET 220V ELECTRICAL OUTLET SWITCHED DUPLEX ELECTRICAL OUTLET ELECTRIC PANEL ELECTRIC METER HEIGHT ABOVE FINISHED FLOOR+42" CABLE TV OUTLET EXHAUST FAN ALL ELECTRICAL WORK SHALL COMPLY WITH PART VIII - ELECTRICAL OF THE 2015 INTERNATIONAL RESIDENTIAL CODE. IN THE EVENT OF CONFLICT BETWEEN THE DESIGN DOCUMENTS AND THE 2015 INTERNATIONAL RESIDENTIAL CODE, THE CODE SHALL PREVAIL. ELECTRICAL CONTRACTOR SHALL NOTIFY ARCHITECT OF AND CONDITIONS THAT DO NOT COMPLY WITH SUCH CODES. PROVIDE CODE MINIMUM ELECTRICAL OUTLETS THROUGHOUT. GENERAL AND ELECTRICAL CONTRACTORS TO REVIEW & CONFIRM ALL LIGHTING CONTROL, ELECTRICAL OUTLET, AND LOW VOLTAGE DEVICE BOX EXACT LOCATIONS WITH OWNERS VIA WALK-THRU MEETING PRIOR TO RUNNING ALL WIRING. PROVIDE CONCEALED POP-UP OUTLETS AT KITCHEN ISLAND LOCATIONS G.C. TO PROVIDE 2xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE AT NEW DATA TELEPHONE/LOCATIONS. (ALLOWS FOR PHONE, INTERCOM, WIRELESS ACCESS POINT, LAN, ETC.) G.C. TO PROVIDE 2xRG6 & 4xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE.AT NEW/FUTURE TELEVISION LOCATIONS ELECTRICAL FIXTURES AND DEVICES AS GRAPHICALLY INDICATED ON PLANS ARE INTENDED TO ILLUSTRATE LAYOUT ONLY. LAYOUT OF RECESSED AND SURFACE MOUNTED CEILING FIXTURES ARE GENERALLY CENTERED, ALIGNED, AND EQUALLY SPACED AS INDICATED ON PLANS. EXACT DIMENSIONS ARE AVAILABLE UPON REQUEST FROM LIGHTING DESIGNER. ARCHITECT AND OWNER TO REVIEW RECESSED FIXTURE LOCATIONS PRIOR TO CEILING FINISH INSTALLATION. PROVIDE SMOKE & CO DETECTORS THROUGHOUT THE RESIDENCE AS REQ'D BY LOCAL CODE OFFICIAL. PROVIDE ASSOCIATED SECURITY SYSTEM WITH MOTION SENSORS, GLASS BREAKS, WINDOW AND DOOR SENSORS, FREEZE AND FLOOD SENSORS, GAS DETECTORS, SYSTEM KEYPAD, ETC. LIGHTING AND OTHER NECESSARY LIGHTING FIXTURES TO BE SELECTED BY THE OWNER OR THE OWNER'S REPRESENTATIVE UNLESS NOTED OTHERWISE.COUNTER AIR SWITCH 1. 2. 3. 4. 5. 6. 7. SURFACE MONOPOINT LIGHT FIXTURE PENDANT LIGHT FIXTURE RECESSED CAN LIGHT FIXTURE ADJUSTABLE RECESSED CAN LIGHT FIXTURE LED 45° CHANNEL LIGHT FIXTURE WALL MOUNTED LINEAR ART LIGHT FITURE RECESSED LED LIGHT STRIP WALL MOUNTED DOWN LIGHT FIXTURE ADJUSTABLE RECESSED LED CAN LIGHTING FIXTURES (INTERIOR) L1 L2 L3 L4 L5 L6 QTY.HIGH EFFICACY YES SURFACE MOUNTED, ADJUSTABLE LED MONOPOINT DECORATIVE LED PENDANT DINING DECORATIVE LED PENDANT NO WALL MOUNTED LINEAR ART LED FIXTURE YES NO YES RECESSED / COVE LINEAR LED FIXTURE YES L7 YESLINEAR LED CABINET FIXTURE, HINGE SWITCH (SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.) L8 DECORATIVE LED PENDANT L9 DECORATIVE LED PENDANT NO DESCRIPTIONTAG NO WALL MOUNTED LED DOWN LIGHT, DARK SKY COMPLIANT, REFER TO EXTERIOR ELEVATIONS LIGHTING FIXTURES (EXTERIOR) L12 QTY.HIGH EFFICACY YES (SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.) DESCRIPTIONTAG L10 NOLED WALL LAMP L11 WET LOCATION ADJUSTABLE LED CAN YES 54 8 2 1 1 9 16 1 2 2 1 LIGHTING NOTES: 1. REFER TO PLANS & ELECTRICAL LEGEND FOR ADJUSTABLE/FIXED RECESSED CAN LIGHT FIXTURE LOCATIONS. 2. CONTRACTOR TO CONFIRM FIXTURE QUANTITIES PRIOR TO ORDERING. HIGH EFFICACY LIGHTING CALCULATION MINIMUM REQUIRED PERCENTAGE OF HIGH EFFICACY LIGHT FIXTURES: TOTAL PROVIDED LIGHT FIXTURES: TOTAL PROVIDED HIGH EFFICACY LIGHT FIXTURES: PERCENTAGE OF HIGH EFFICACY LIGHT FIXTURES: 50% 103 95 95/103 = 92.2% EXISTING TO REMAIN RECESSED LED CAN LIGHTER1 (E)2 5 EXISTING RELOCATED FLOOD LIGHTER2 YES1 EXISTING TO REMAIN WALL MOUNTED DOWN LIGHTER3 (E)3 NEW/MODIFIED FIXTURES ONLY WE I S S R E S I D E N C E 52 3 W E S T S M U G G L E R S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 11 1 H A A B C As p e n , C O 8 1 6 1 1 97 0 . 9 4 8 . 6 7 0 9 ba r r y . g e r e b @ b g a d a s p e n . c o m bg AR C H I T E C T U R E & D E S I G N CD SET 2/5/21 NO T F O R C O N S T R U C T I O N A1.3 SECOND LEVEL REFLECTED CEILING PLAN SECOND LEVEL REFLECTED CEILING PLAN 1/4" = 1'-0" 1 A1.3 east elevation scale: 1/4" = 1'-0"3 AREA OF PROPOSED WORK AREA OF PROPOSED WORK AREA OF PROPOSED WORK BEYOND: SEE 2/A2.0 NOTES: 1. INSULATION AT PROPOSED INFILL AREAS TO MATCH EXISTING 2.INFILL WALL AT REMOVED WINDOWS, PROVIDE SIDING AND PAINT TO MATCH EXISTING, TYP. PROPOSED GAS APPLIANCE TO VENT IN EXISTING MINERS CABIN CHIMNEY IN EXISTING VENT ENCLOSURE. NO CHANGES TO MINER'S CABIN EXTERIOR PROPOSED N1 E1 E2 1 N3 N3 N2N2 L12 L12 ER2 bg AR C H I T E C T U R E & D E S I G N 2/5/21 A2.0 BUILDING ELEVATIONS AREA OF PROPOSED WORK RANGE VENT AREA OF PROPOSED WORK BEYOND: SEE 2/A2.1 AREA OF PROPOSED WORK S1 W4 W1 W2 W3 NOTES: 1. INSULATION AT PROPOSED INFILL AREAS TO MATCH EXISTING 2.INFILL WALL AT REMOVED WINDOWS, PROVIDE SIDING AND PAINT TO MATCH EXISTING, TYP. PROVIDE FINISH TO MATCH EXISTING SIDING @ OUTDOOR KITCHEN, FLASH TO EXISTING BUILDING AS REQUIRED, OUTDOOR KITCHEN DOES NOT TOUCH EXISTING MINER'S CABIN S2 W5 PROVIDE MIN 48" WIDE SECTION OF FIBER-CEMENT OR EQUIVALENT NON-COMBUSTIBLE BOARD & BATTEN FINISH MATERIAL CENTERED BEHIND GRILL UNIT PROVIDE BLACK ALUMINUM BRAKE METAL TO MATCH CORNER WINDOW DETAIL PROVIDE TRIM TO MATCH PROVIDE TRIM TO MATCH PROVIDE TRIM TO MATCH L12L12 ER3 ER3 ER3 L12 bg AR C H I T E C T U R E & D E S I G N 2/5/21 A2.1 BUILDING ELEVATIONS E1 WINDOW MATERIAL OPERATION WINDOW SCHEDULE UNIT SIZE (W X H)U-VALUEMANUFACTURER NOTES E2 S1 W1 W2 W3 W4 N1 N2 N3 TBD TBD TBD 66"X18" 84"X12" 60"X72" 24"X18" 144"X18" 84"X12" 24"X18" 60"X75" 24"X42" 84"X96" CLAD/WOOD CLAD/WOOD CLAD/WOOD AWNING FIXED GLASS FIXED GLASS FIXED GLASS FIXED GLASS FIXED GLASS SLIDING DOOR XO FIXED GLASS SLIDING DOOR OX 0.28 MAX. 0.28 MAX. 0.28 MAX. HEAD HEIGHT = 8'-0" AFF, DIRECT SET INSULATED GLASS HEAD HEIGHT AS HIGH AS POSSIBLE, RE: STRUCTURAL SAFETY GLAZING, MATCH EXISTING HEAD HEIGHT PELLA ARCHITECTURAL CONTEMPORARY SERIES, SAFETY GLAZING PELLA ARCHITECTURAL CONTEMPORARY SERIES, SAFETY GLAZING DOOR LOCATION UNIT SIZE MATERIAL CLAD/WOOD OPERATION SLIDING DOOR OXX HARDWARE EXTERIOR DOOR SCHEDULE NOTES 126"x96" THICKNESS 1-3/4"ENTRY NOTES: 1. CONTRACTOR TO CONFIRM DOOR SIZES AND DETAILS WITH ARCHITECT PRIOR TO ORDERING 2. BEAR RESISTANT DOOR HARDWARE 3. U-VALUE: .28 MAXIMUM 4. DOOR CLADDING COLOR TO MATCH EXISTING PELLA ARCHITECTURAL CONTEMPORARY SERIES, LOCATE IN EXISTING OPENINGPATIO ENTRY 8' - 0 " 10'-6" TBD CLAD/WOOD 0.28 MAX. TBD CLAD/WOOD FIXED GLASS 0.28 MAX. HEAD HEIGHT = 8'-0" AFF, DIRECT SET INSULATED GLASS WINDOW SCHEDULE NOTES: - CONTRACTOR TO CONFIRM WINDOW SIZE AND DETAILS WITH ARCHITECT PRIOR TO ORDERING. - ALL EXTERIOR CLADDING COLOR SHALL MATCH EXISTING. 0.28 MAX. 0.28 MAX. 0.28 MAX. 0.28 MAX. 0.28 MAX. CLAD/WOOD CLAD/WOOD CLAD/WOOD CLAD/WOOD CLAD/WOOD TBD TBD TBD TBD TBD N1 N2 N3 E1 E2 S1 W4W1W2 5'-0"2'-0"7'-0"5'-6"7'-0" 5'-0"2'-0" 12'-0" EQ.EQ.EQ.7'-0"2'-0" 1' - 6 " 1' - 0 " 1' - 6 " 1' - 6 " 6' - 0 " 1' - 0 " 1' - 6 " 8' - 0 " F I E L D V E R I F Y 3' - 6 " 6' - 3 " F I E L D V E R I F Y 1 1 RAILING AT NORTH EDGE OF EXISTING STAIR. RAILING AT NORTH EDGE OF EXISTING STAIR TERMINATES BEYOND MECH CHASE WALL ON LANDING ROUND WOOD CAP TO MATCH EXISTING <4" <6" RAILING TO MATCH OPPOSITE SIDE OF STAIR WHERE CABINET TO BE REMOVED 3' - 0 " M I N . FI E L D V E R I F Y E X I S T I N G R . O . STAIR RAILING 3/4" = 1'-0" 1 A3.0MINER'S CABIN GAS APPLIANCE 1/4" = 1'-0" 2 A3.0 DOOR ELEVATIONS (VIEW FROM EXTERIOR) 1/4" = 1'-0"A3.0 WINDOW ELEVATIONS (VIEW FROM EXTERIOR) 1/4" = 1'-0" 4 A3.0 EXISTING WOOD TREADS STEEL ROUND BARS, TO MATCH EXISTING STEEL PLATE POSTS TO MATCH EXISTING MINER'S CABIN GAS FIREPLACE APPLIANCE 1/4" = 1'-0" 2 A3.0 3 HEAD HEIGHT = 8'-0" AFF S2 TBD 60"X60"CLAD/WOOD FIXED GLASS 0.28 MAX.MATCH EXISTING HEAD HEIGHT MATCH EXISTING HEAD HEIGHT, MOTORIZED OPERATION S2 5'-0" 5' - 0 " W5 66"X18"AWNING MATCH EXISTING ADJACENT WINDOW HEAD HEIGHTS, MOTORIZED OPERATION0.28 MAX.CLAD/WOODTBD MATCH EXISTING HEAD HEIGHT MATCH EXISTING HEAD HEIGHT W3 W5 5'-6" 1' - 6 " U-VALUE 0.28 MAX. RAILING AT NORTH EDGE OF EXISTING STAIR. RAILING AT NORTH EDGE OF EXISTING STAIR TERMINATES BEYOND MECH CHASE WALL ON LANDING ROUND WOOD CAP TO MATCH EXISTING <4" <6" RAILING TO MATCH OPPOSITE SIDE OF STAIR WHERE CABINET TO BE REMOVED 3' - 0 " M I N . STAIR RAILING 3/4" = 1'-0" 1 A3.0 EXISTING WOOD TREADS STEEL ROUND BARS, TO MATCH EXISTING STEEL PLATE POSTS TO MATCH EXISTING bg AR C H I T E C T U R E & D E S I G N 2/5/21 A3.0 SCHEDULES & DETAILS bg AR C H I T E C T U R E & D E S I G N 2/5/21 A4.0 SPECIFICATIONS SCALE: NOT TO SCALE OUTDOOR GRILL1 A4.0SCALE: NOT TO SCALE EXTERIOR LIGHT FIXTURE2 A4.0