HomeMy WebLinkAboutApproved Drawings.523 W Smuggler StWE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
T1.0
PROJECT DATA
SHEET #TITLE
T1.0 PROJECT DATA
T1.1 GENERAL NOTES
ARCHITECTURAL:
SP1.0 SITE PLAN & EXISTING/DEMO SITE PLAN
CC1.0 CODE COMPLIANCE
D1.0 GROUND LEVEL EXISTING/DEMO FLOOR PLANS
D1.1 SECOND LEVEL EXISTING/DEMO FLOOR PLANS
D2.0 EXISTING & DEMO BUILDING ELEVATIONS
D2.1 EXISTING & DEMO BUILDING ELEVATIONS
A1.0 GROUND LEVEL FLOOR PLAN
A1.1 SECOND LEVEL FLOOR PLAN
A1.2 GROUND LEVEL REFLECTED CEILING PLAN
A1.3 SECOND LEVEL REFLECTED CEILING PLAN
A2.0 BUILDING ELEVATIONS
A2.1 BUILDING ELEVATIONS
A3.0 SCHEDULES & STAIR DETAILS
A4.0 SPECIFICATIONS
STRUCTURAL:
#TBD SHEET NAME TBD
WEISS RESIDENCE
523 WEST SMUGGLER STREET
ASPEN, COLORADO 81611
JURISDICTION
JURISDICTION ENTITY
ADDRESS
PHONE NUMBER
BUILDING CODE:
2015 INTERNATIONAL RESIDENTIAL CODE (2015 IRC)
2015 INTERNATIONAL ENERGY CONSERVATION CODE (2015 IECC)
PROJECT CONTACTS:
N
SCALE: NOT TO SCALE
VICINITY MAP
PROJECT DATA:
INTERIOR
MINER'S CABIN
1. REPLACE EXISTING INTERIOR GAS APPLIANCE FIREPLACE AND SURROUND UTILIZING THE EXISTING VENT PATH TO THE EXISTING
CHIMNEY. NO CHANGES TO THE EXISTING EXTERIOR CHIMNEY ARE PROPOSED.
2002 ADDITION
1. DEMOLITION & REMOVAL OF EXISTING KITCHEN TO BECOME DINING ROOM. ADD NEW CASEWORK.
2. DEMOLITION & REMOVAL OF EXISTING GAS FIREPLACE ADJACENT STAIR.
3. DEMOLITION & REMOVAL OF EXISTING MASTER BATHROOM AND CLOSET FIXTURES & FINISHES.
4. DEMOLITION & REMOVAL OF INACTIVE HVAC EQUIPMENT ABOVE EXISTING MASTER BATHROOM & ENTRY CLOSET.
5. CONSTRUCTION OF NEW MASTER SUITE INTERIOR WALLS, LIGHTING AND PLUMBING FIXTURES.
6. CONSTRUCTION OF NEW KITCHEN IN NEW LOCATION WITH CABINETRY & APPLIANCES.
EXTERIOR
MINER'S CABIN
1. NO CHANGES TO EXISTING STRUCTURE ARE PROPOSED
2002 ADDITION
1. NORTH ELEVATION
-DEMOLITION & REMOVAL OF PATIO DOOR @ MASTER BEDROOM AND EXISTING LIVING ROOM, INFILL WITH FRAMING,
PROVIDE INSULATION, PATCH SIDING TO MATCH.
-DEMOLITION & REMOVAL OF WINDOWS @ MASTER SUITE AND EXISTING LIVING ROOM, INFILL WITH FRAMING, PROVIDE
INSULATION, PATCH SIDING TO MATCH.
-REMOVAL OF EXISTING WALL MOUNTED LIGHTING
-CONSTRUCTION OF NEW WINDOW AT MASTER BEDROOM.
-CONSTRUCTION OF NEW SLIDING DOOR AT NEW KITCHEN.
-CONSTRUCTION OF NEW WALL MOUNTED DOWN LIGHTING.
2. EAST ELEVATION
-DEMOLITION AND REMOVAL OF WINDOW AT DINING ROOM, INFILL WITH FRAMING, PROVIDE INSULATION, PATCH SIDING
TO MATCH.
-REMOVAL OF EXISTING WALL MOUNTED LIGHTING.
-CONSTRUCTION OF NEW WINDOWS AT NEW DINING ROOM AND MASTER BEDROOM.
-CONSTRUCTION OF NEW OUTDOOR KITCHEN WITH NATURAL GAS GRILL ADJACENT TO NEW DINING ROOM
3. SOUTH ELEVATION
-DEMOLITION & REMOVAL OF WINDOW @ DINING ROOM & MASTER BEDROOM, INFILL WITH FRAMING, PROVIDE
INSULATION, PATCH SIDING TO MATCH.
-REMOVAL OF EXISTING WALL MOUNTED LIGHTING.
-CONSTRUCTION OF NEW WINDOW @ DINING ROOM AND MASTER BEDROOM.
-CONSTRUCTION OF NEW WALL MOUNTED DOWN LIGHTING.
4. WEST ELEVATION
-DEMOLITION & REMOVAL OF WINDOWS @ EXISTING KITCHEN & LIVING ROOM. INFILL WITH FRAMING, PROVIDE
INSULATION, PATCH SIDING TO MATCH.
-CONSTRUCTION OF NEW WINDOWS @ NEW KITCHEN
-CONSTRUCTION OF OUTDOOR KITCHEN AT EAST SIDE OF 2002 ADDITION.
PROJECT SCOPE:
COMPLIANCE METHOD 1: PRESCRIPTIVE / UA TRADEOFF (2015 IRC SECTION N1101.13
ENERGY COMPLIANCE:
LEVEL OF ALTERATION: LEVEL 1 ALTERATION
(2015 IEBC CHAPTER 5)
PROPERTY TYPE: SINGLE FAMILY RESIDENCE
FIRE PROTECTION:NON-SPRINKLERED
CONSTRUCTION TYPE: VB
OCCUPANCY: R3
BUILDING HEIGHT:EXISTING TO REMAIN
GROSS FLOOR AREA:EXISTING TO REMAIN
CODE ANALYSIS:
SUBDIVISION: HISTORIC LANDMARK AT 513 W SMUGGLER ST LOT: A
LEGAL DESCRIPTION:
523 WEST SMUGGLER STREET
ASPEN, COLORADO 81611
PARCEL ID: 273512499001
PROJECT ADDRESS:SHEET INDEX:
OWNER:
SOL H AND FAITH E WEISS
1706 RITTENHOUSE SQ #1401
PHILADELPHIA, PA 19103
(215) 285 9143
SWEISS@ANAPOLWEISS.COM
DESIGNER/ARCHITECT:
BG ARCHITECTURE & DESIGN, LLC
111H ASPEN AIRPORT BUSINESS CENTER
ASPEN, CO 81611
T. (970) 948 6709
CONTACT: BARRY GEREB
BARRY.GEREB@BGADASPEN.COM
STRUCTURAL ENGINEER:
SILVER TOWN STRUCTURES
307N ASPEN AIRPORT BUSINESS CENTER
ASPEN, CO 81611
T. (970) 300 1003
CONTACT: HEIN BRUTSAERT
HEIN3@SOPRIS.NET
CONTRACTOR:
BUILD WEST CUSTOM HOMES
PO BOX 9085
ASPEN, CO 81612
(970) 618 6823
CONTACT: JACOB DOWN
JD@BUILDWEST.COM
523 WEST
SMUGGLER
MAIN STR
E
E
T
E
A
S
T
C
O
O
P
E
R
A
V
E
N
U
E
HIGH
W
A
Y
8
2
SMUGGL
E
R
S
T
R
E
E
T
NO
R
T
H
5
T
H
S
T
R
E
E
T
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
T1.1
GENERAL NOTES & LEGEND
D01
A
1
A3.0
1
A3.0
1
A3.0
1
A5.0
1
A2.0
4
1
2
3
CONCRETE
CONCRETE
MASONRY
STONE
FRAME WALL
TILE
STEEL
ALUMINUM OR
SHEET METAL
BATT INSULATION
GYP. WALL
BOARD/ STUCCO
/PLASTER
PLYWOOD
SOIL/
COMPLACTED
FILL
ROCK/
NON-COMPACTED
FILL/ GRAVEL
SAND/ GWB/
PLASTER
FINISHED WOOD
ROUGH FRAMING
OR ROUGH
SAWN TRIM
WOOD BLOCKING
GLU-LAM WOOD
PARTICAL BOARD
OR WOOD FIBER
BOARD
RIGID INSULATION
CARPET
1
BUILDING SECTION
CUT
WALL SECTION
CUT
DETAIL
DETAIL CUT
EXTERIOR
ELEVATION
ROOM NUMBER
DOOR MARK
GRID
REFERENCE
LINE
SPOT ELEVATION
DRAWING
REVISION
INTERIOR
ELEVATION
WINDOW MARK
SYMBOL LEGEND
MATERIALS LEGEND
ABBREVIATIONS
AAD ATTIC ACCESS DOOR
ADD ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
ALT ALTERNATE
AOR AREA OF REFUGE
ARCH ARCHITECTURAL
ASS'Y ASSEMBLY
B/O BOTTOM OF
BD BOARD
BTW BETWEEN
BLDG BUILDING
BM BEAM
BRG BEARING
BS BOTH SIDES
CAB CABINET
CER CERAMIC
CJ CONSTRUCTION JOINT
CL CENTERLINE
CLST CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
D DRYER
DET DETAIL
DIA DIAMETER
DIM DIMESION
DN DOWN
DP DAMPPROOFING
DR DRAIN
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
FFA FINISH FLOOR
FDN FOUNDATION
FE CABT FIRE EXTINGUISHER
FIN FINISH
FL FLOOR
FOC FACE OF CONCRETE
FOS FACE OF STUD
FR FIREPROOFING
FTG FOOTING
GA GAUGE
GALV GALVINIZED
GC GENERAL CONTRACTOR
GLB GLU-LAM BEAM
GR GRADE
GWB GYPSUM
WALLBOARD
GYP GYPSUM
H.T.A. HEAVY TIMBER
HD HEAD
HDW HARDWARE
HOR HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATING, AND COOLING
HWY HIGHWAY
IBC INTERNATIONAL BUILDING CODE
ICP INTEGRATED COLOR PLASTER
ID INSIDE DIAMETER
IE THAT IS
INT INTERIOR
INS INSULATION
IRC INTERNATIONAL RESIDENTIAL CODE
JT JOINT
LAM LAMINATE
LAV LAVATORY
LH LEFT HAND
LHR LEFT HAND
REVERSE
MAX MAXIMUM
MC MEDICINE CABINET
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL MATERIAL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMTER
OPG OPENING
OPH OPPOSITE HAND
OPP OPPOSITE
PERF PERFORATED
PFSM PREFINISHED SHEET METAL
PL PLATE
PLY PLYWOOD
PROD PRODUCT
PROJ PROJECT
PROP PROPERTY
R RADIUS / RISER
REF REFER
REFR REEFRIGERATOR
REQ'D REQUIRED
RH RIGHT HAND
RHR RIGHT HAND REVERSE
RHSM ROUND HEAD
SHEET METAL
RM ROOM
RO ROUGH OPENING
S.T.D.A. SLOPE TO DRAIN
SAN SANITARY
SECT SECTION
SEW SEWER
SG SAFETY GLAZING
SHLV SHELVES
SHT SHEET
SIM SIMILAR
SM/CO SMOKE / CO
DETECTOR
SPEC SPECIFICATION
SQ SQAURE
STC SOUND TRANSMISSION CLASS
STL STEEL
STRUCT STRUCTUR(AL)
SUB SUBSTITUTE
SUPPL SUPPLEMENT(AL)
SUSP SUSPEND(ED)
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T/O TOP OF
TEL TELEPHONE
TEMP TEMPERED
THK THICK
TPH TOILET PAPER
HOLDER
TS TUBE STEEL
TV TELEVISION
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
UBC UNIFORM BUILDING CODE
UG UNDERGROUND
UNFIN UNFINISHED
USG UNITED STATES GAUGE
V.I.F.A. VERIFY IN FIELD
VAR VARIABLE
VENT VENTILATE(D)
VG VERTICAL GRAIN
W WASHER
WD WOOD
EL. 100'-0"
MAIN LEVEL
GENERAL NOTES CODE NOTES
A9.0
1. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES,
AND SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF CRAFTSMANSHIP BY
JOURNEYMEN OF THE APPROPRIATE TRADES.
2. ALL DRAWINGS REPRESENTED, AND DIMENSIONS SHOWN, ARE TO BE FACE OF
STUD AT WALL, FACE OF CONCRETE, OR CENTER LINE OF COLUMNS UNLESS NOTED
OTHERWISE.
3. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED DIMENSIONS.
DIMENSIONS NOTED “N.T.S.” DENOTE NOT TO SCALE.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DESCRIPTIONS, EXISTING AND
PROPOSED, AND JOB SITE CONDITIONS, PRIOR TO STARTING WORK.
5. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF
THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING
TO THE INTENTIONS OF THESE DOCUMENTS. THE ARCHITECT MAY PROVIDE
SUPPLEMENTAL INFORMATION REGARDING DESIGN INTENT WHERE ACCOMMODATIONS
FOR EXISTING CONDITIONS, OR WHERE SUFFICIENT INFORMATION, IS ABSENT FROM THE
THESE DOCUMENTS.
6. SHOULD A DISCREPANCY OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS,
CONSULT THE ARCHITECT IMMEDIATELY AND PRIOR TO COMMENCING WORK.
7. CONTRACTOR WILL ASSUME RESPONSIBILITY FOR ITEMS REQUIRING
COORDINATION AND RESOLUTION DURING THE BIDDING PROCESS. THE CONTRACTOR
SHALL CONTACT THE ARCHITECT FOR ANY CLARIFICATIONS. THE CONTRACTOR SHALL
CONTACT THE ARCHITECT FOR PRIOR APPROVAL BEFORE EXCLUDING ANY ITEMS OR
PRODUCTS FROM THEIR BID.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT
PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE
O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED
COMPLETED TO THE OWNER.
9 ANY QUESTIONS REGARDING THE INTENT OF THE DRAWINGS OR SPECIFICATIONS ARE
TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO ORDERING MATERIALS OR
PROCEEDING WITH THE RELATED WORK.
10. THESE DOCUMENTS REPRESENT THE COMPLETED PROJECT. CONTRACTOR IS
SOLELY RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION.
11. EACH MISCELLANEOUS ITEM OF CUTTING, PATCHING, OR FITTING IS NOT
NECESSARY INDIVIDUALLY DESCRIBED IN THESE DOCUMENTS. NO SPECIFIC
DESCRIPTION OF CUTTING, PATCHING, OR FITTING REQUIRED TO PROPERLY
ACCOMMODATE THE SCOPE OF WORK SHALL RELIEVE THE CONTRACTOR FROM THE
RESPONSIBILITY TO PERFORM SUCH WORK AS MAY BE REQUIRED TO COMPLETE THE
PROJECT.
12. ALL ITEMS ARE NEW UNLESS CALLED OUT AS “EXISTING”.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL
NEW CONSTRUCTION.
14. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS,
CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL,
PLUMBING, ELECTRICAL, AND OTHER DISCIPLINE DRAWINGS, SPECIFICATIONS, AS WELL
AS EXISTING CONDITIONS.
15. ALL WORK SHALL BE ERECTED PLUMB AND TRUE-TO-LINE IN ACCORDANCE WITH
BEST PRACTICES OF THE TRADE, MANUFACTURER'S RECOMMENDATIONS FOR THE
PARTICULAR PRODUCT, AND IN ACCORDANCE WITH THE SPECIFICATIONS.
16. WHERE INSTALLED WORK IS DAMAGED OR EXISTING FINISHES ARE DISTURBED
DURING CONSTRUCTIONS, SUCH AREAS SHALL BE BE REFINISHED TO MATCH THE AREA
PRIOR TO BEING DAMAGED OR DISTURBED.
17. CONTRACTOR TO PROVIDE THERMAL INSULATION AT ALL EXTERIOR WALLS,
FLOORS AND CEILINGS. PROVIDE FIRE SEPARATIONS AS REQUIRED.
18. CONTRACTOR SHALL TAKE FULL RESPONSIBILITY TO FLASH, SEAL, AND
WATERPROOF THE ENTIRE BUILDING ENCLOSURE.
19. CONTRACTOR TO VERIFY AND PROVIDE ALL MECHANICAL AND PASSIVE VENTING
AND FRESH AIR SUPPLY AS REQUIRED.
20. CONTRACTOR SHALL DO ALL CUTTING, FITTING, PATCHING, EXCAVATION, OR
OTHER REQUIRED TASK OF THEIR WORK THAT MAY BE REQUIRED FOR ALL
SUBCONTRACTORS TO BE ABLE TO PERFORM THEIR WORK. THIS CUTTING, FITTING,
PATCHING, EXCAVATION, OR OTHER REQUIRED TASK SHALL NOT ENDANGER OTHER
WORK OR STRUCTURES. ALL PATCHING OR REPAIRING SHALL BE DONE WITH LIKE
MATERIALS SO THAT SURFACES REPLACED WILL MATCH SURROUNDING SURFACES UPON
COMPLETION.
21. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN AND ORDERLY CONDITION. EACH
SUBCONTRACTOR, IMMEDIATELY UPON COMPLETION OF EACH PHASE OF WORK, SHALL
REMOVE ALL DEBRIS AS A RESULT OF THEIR WORK.
22. NO PORTION OF WORK REQUIRING SHOP DRAWINGS OR SAMPLE SUBMISSION
SHALL BE COMMENCED UNTIL THE SHOP DRAWING OR SAMPLE HAS BEEN REVIEWED BY
THE ARCHITECT AND/OR THE STRUCTURAL ENGINEER.
23. THE LOCAL GOVERNMENT AGENCIES SHALL BE NOTIFIED BY THE CONTRACTOR
WHEN THERE IS A NEED OF INSPECTION AS REQUIRED BY THE APPLICABLE CODE OR BY
ANY LOCAL CODE OR ORDINANCE.
24. ANY CHANGES TO THESE DOCUMENTS MADE BY ANYONE EXCEPT THE ARCHITECT
ARE THE RESPONSIBILITY OF THE PERSON MAKING, OR AUTHORIZING, THE CHANGE. THE
ARCHITECT SHALL NOT BE RESPONSIBLE FOR CHANGES OR DETAILS MADE BY OTHERS.
25. THE PRESENCE OF THE ARCHITECT ON THE JOB SITE DOES NOT IMPLY
CONCURRENCE OR APPROVAL OF THE WORK. THE CONTRACTOR SHALL CALL SPECIFIC
ITEMS TO THE ATTENTION OF THE ARCHITECT TO OBTAIN THE ARCHITECT'S REVIEW.
26. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT, THE GENERAL
CONDITIONS, SUPPLEMENTARY CONDITIONS, GENERAL PROVISIONS, DRAWINGS,
SPECIFICATIONS, ADDENDA, AND SUPPLEMENTARY DOCUMENTS AS ISSUED BY THE
ARCHITECT IN ACCORDANCE WITH THE GENERAL AND SUPPLEMENTARY CONDITIONS OF
THE CONTRACT. DRAWINGS AND SPECIFICATIONS ARE COOPERATIVE AND CONTINUOUS.
WORK INDICATED OR REASONABLY IMPLIED IN EITHER SHALL BE PROVIDED AS THOUGH
FULLY COVERED BY BOTH. ANY DISCREPANCY BETWEEN THE CONTRACT DOCUMENTS
SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY.
1.APPLICABLE BUILDING CODES:
-2015 INTERNATIONAL RESIDENTIAL CODE (2015 IRC)
-2015 INTERNATIONAL EXISTING BUILDING CODE (2015 IEBC)
-2015 INTERNATIONAL PLUMBING CODE (2015 IPC)
-2015 INTERNATIONAL MECHANICAL CODE (2015 IMC)
-2015 INTERNATIONAL FUEL & GAS CODE (2015 IGFC)
-2015 INTERNATIONAL ENERGY CONSERVATION CODE (2015 IECC)
LEVEL 2 ALTERCATION:
ALL WORK TO BE PERFORMED SHALL CONFORM WITH CURRENTLY ADOPTED CODES.
XXX
1 20.5 SF
2 39.7 SF
3 12.3 SF
4 8.1 SF
5 7.3 SF
6 19.6 SF
7 68.9 SF
8 104.6 SF
9 10.5 SF
10 48.9 SF
11 14.5 SF
12 45.5 SF
13 60.2 SF
14 20.8 SF
15 8.2 SF
16 31.8 SF
17 60.5 SF
TOTAL 581.8 SF PROPOSED DEMO AREA
DEMO AREA
1 2 3 4 5 6 7
12
8 10
11 13 14 15 16 17
9
20.5 SF 39.7 SF 12.3 SF 8.1 SF 7.3 SF 19.6 SF 68.9 SF
45.5 SF
104.6 SF 48.9 SF
14.5 SF 60.2 SF 20.8 SF 8.2 SF 31.8 SF 60.5 SF
10.5 SF
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
2/5/21
CC1.0
CODE COMPLIANCE
LOT A
LOT B
LOT A
LOT B
EXISTING SITE PLAN
1/8" = 1'-0"
1
SP1.0
PROPOSED SITE PLAN
1/8" = 1'-0"
2
SP1.0
AREA OF PROPOSED WORK:
8'-0" X 2'-9" OUTDOOR KITCHEN W/
NATURAL GAS GRILL
CONCRETE PAVER PATIO & WALK
CONCRETE
PAVER PATIO
CO
N
C
R
E
T
E
P
A
V
E
R
W
A
L
K
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
SP1.0
SITE PLAN
ABCDEFG
1
2
3
4
5
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
1
D2.0
2
D2.0
3
D2.0
1
D2.1
2
D2.1
3
D2.1
OVERHANG
ABOVE
OVERHANG
ABOVE
DN
1R
LINE OF HEADER
ABOVE
LINE OF HEADER
ABOVE
GARAGE
STAIR
EGRESS WELL OFFICE FRONT
PORCH
MINERS CABIN
POWDER
ENTRY
KITCHEN
DINING
ROOM
HALLMUDROOM
EGRESS WELL
1 1
1
11
1
1
2
3
3
3
134
48
4
4
4
6
5
13
4 4
5 6
3
3
2
2
27
7
7
4
10
4
4
12
12
9
3
13
2
14
15
1616
REMOVE EXISTING WINDOW
REMOVE EXISTING DOOR
REMOVE EXISTING WALL AT PROPOSED WINDOW/DOOR OPENING
REMOVE EXISTING GAS APPLIANCE: FIREPLACE
REMOVE EXISTING FIREPLACE SURROUND
REMOVE EXISTING PLUMBING FIXTURE
1
2
3
4
5
6
7
FLOOR CEILING PLAN DEMOLITION NOTES
REMOVE EXITING CABINET / BUILD-IN FURNITURE
REMOVE EXISTING GAS APPLIANCE: RANGE, OVEN AND HOOD8
REMOVE EXISTING CEILING FINISH & FRAMING AT PROPOSED
ACCESS PANEL
9
REMOVE EXISTING ACCESS PANEL10
REMOVE EXISTING SHOWER ENCLOSURE11
REMOVE EXISTING EXTERIOR FINISH MATERIAL BELOW 36" AFF12
REMOVE EXISTING WALL, PATCH & REPAIR DRYWALL13
EXISTING SNOWMELT CONTROL PAD TO BE RELOCATED14
EXISTING AWNING & CONTROLS TO BE REMOVED15
EXISTING FLAGSTONE PATIO & WALK TO BE REMOVED16
ALL LIGHT FIXTURES IN THE MINER'S CABIN, OFFICE, POWDER, ENTRY,
KITCHEN, DINING, HALL MUDROOM AND EXTERIOR SHALL BE
REMOVED UNLESS NOTED OTHERWISE, RE: LIGHTING SCHEDULE &
REFLECTED CEILING PLANS. ALL OTHER INTERIOR LIGHTING SHALL BE
EXISTING TO REMAIN UNLESS NOTED OTHERWISE.
ALL EXTERIOR LIGHT FIXTURES SHALL BE REMOVED UNLESS NOTED
OTHERWISE, RE: LIGHTING SCHEDULE & REFLECTED CEILING PLANS
GENERAL DEMOLITION NOTES
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
D1.0
GROUND LEVEL
DEMOLITION PLAN
GROUND LEVEL EXISTING/DEMOLITION PLAN
1/4" = 1'-0"
1
D1.0
DE
1
2
3
4
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
2
D2.0
3
D2.0
2
D2.1
3
D2.1
MASTER BEDROOM
MA
S
T
E
R
BA
T
H
R
O
O
M
MASTER
CLOSET
VESTIBULE
MASTER
ROOFDECK
1
1
1 ABOVE
1
11
1 1
2
2
2
2
3
3
13
13 13
13
3
3
4 4
9
10
4
7
7
7
7
7
11
3
REMOVE EXISTING WINDOW
REMOVE EXISTING DOOR
REMOVE EXISTING WALL AT PROPOSED WINDOW/DOOR OPENING
REMOVE EXISTING GAS APPLIANCE: FIREPLACE
REMOVE EXISTING FIREPLACE SURROUND
REMOVE EXISTING PLUMBING FIXTURE
1
2
3
4
5
6
7
FLOOR CEILING PLAN DEMOLITION NOTES
REMOVE EXITING CABINET / BUILD-IN FURNITURE
REMOVE EXISTING GAS APPLIANCE: RANGE, OVEN AND HOOD8
REMOVE EXISTING CEILING FINISH & FRAMING AT PROPOSED
ACCESS PANEL
9
REMOVE EXISTING ACCESS PANEL10
REMOVE EXISTING SHOWER ENCLOSURE11
REMOVE EXISTING EXTERIOR FINISH MATERIAL BELOW 36" AFF12
REMOVE EXISTING WALL, PATCH & REPAIR DRYWALL13
EXISTING SNOWMELT CONTROL PAD TO BE RELOCATED14
EXISTING AWNING & CONTROLS TO BE REMOVED15
EXISTING FLAGSTONE PATIO & WALK TO BE REMOVED16
ALL LIGHT FIXTURES IN THE MINER'S CABIN, OFFICE, POWDER, ENTRY,
KITCHEN, DINING, HALL MUDROOM AND EXTERIOR SHALL BE
REMOVED UNLESS NOTED OTHERWISE, RE: LIGHTING SCHEDULE &
REFLECTED CEILING PLANS. ALL OTHER INTERIOR LIGHTING SHALL BE
EXISTING TO REMAIN UNLESS NOTED OTHERWISE.
ALL EXTERIOR LIGHT FIXTURES SHALL BE REMOVED UNLESS NOTED
OTHERWISE, RE: LIGHTING SCHEDULE & REFLECTED CEILING PLANS
GENERAL DEMOLITION NOTES
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
D1.1
UPPER LEVEL
DEMOLITION PLAN
SECOND LEVEL EXISTING/DEMOLITION PLAN
1/4" = 1'-0"
1
D1.1
1 2
3 4
5
6 7
2 3 4
5
7
8
9
10
11
AREA OF
PROPOSED
WORK INDICATED
BY HATCH.
RE: CC1.0 FOR
DEMO CALCS
AREA OF
PROPOSED
WORK INDICATED
BY HATCH.
RE: CC1.0 FOR
DEMO CALCS
AREA OF
PROPOSED WORK
BEYOND,
INDICATED BY
HATCH.
RE: CC1.0 FOR
DEMO CALCS
NORTH EXISTING / DEMO ELEVATION
EAST EXISTING / DEMO ELEVATION
SECTION / NORTH ELEVATION ALONG GRID D
3
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
2/5/21
D2.0
EXISTING / DEMOLITION
BUILDING ELEVATIONS
12 12
13
14 15
16
AREA OF
PROPOSED
WORK INDICATED
BY HATCH.
RE: CC1.0 FOR
DEMO CALCS
AREA OF
PROPOSED
WORK INDICATED
BY HATCH.
RE: CC1.0 FOR
DEMO CALCS
AREA OF
PROPOSED WORK
BEYOND,
INDICATED BY
HATCH.
RE: CC1.0 FOR
DEMO CALCS
17
WEST EXISTING / DEMO ELEVATION
SOUTH EXISTING / DEMO ELEVATIONSECTION / SOUTH ELEVATION ALONG GRID E
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
2/5/21
D2.1
EXISTING / DEMOLITION
BUILDING ELEVATIONS
ABCDEFG
1
2
3
4
5
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
1
A2.0
2
A2.0
3
A2.0
1
A2.1
2
A2.1
3
A2.1
DN
1R
OVERHANG
ABOVE
OVERHANG
ABOVE
LINE OF HEADER
ABOVE
OFFICE FRONT
PORCH
MINERS CABIN
PO
W
D
E
R
ENTRY
EGRESS WELL
EGRESS WELL
STAIR
KITCHEN
DINING
HALL
MUDROOMGARAGE
BUILT-IN
CABINET &
SHELVES
4" MAX.
OPENING NEW GUARD RAIL
TO MATCH EXISTING,
RE: 1/A3.0
EXTEND RISER
& NOSING
TO MATCH
EXISTING
MW
D
R
A
W
E
R
&
O
V
E
N
DW TRASH
REF
RANGE &
DOWNDRAFT VENT
PANTRY
CLOSET
BE
N
C
H
BENCH BENCH
CONSOLE BAR
STORAGE
CABINET
EXISTING GUARD
TO REMAIN
EXISTING GUARD
TO REMAIN
EXISTING FENCE
& GATE
W2
W3
S1
N3
E2
1
NATURAL GAS CONNECTION
+36" AFF OUTDOOR KITCHEN
W/ NATURAL GAS GRILL
ON 4" CONCRETE PAD,
FRAME AS REQUIRED BY
GRILL MANUFACTURER
6'-9"
2'
-
6
"
82.54SF OF AVAILABLE DECK
FLOOR AREA REMAINS.
OUTDOOR KITCHEN
UTILIZES 21SF OF FLOOR
AREA FOR A NET
REMAINING DECK AREA OF
61.54SF
OUTDOOR KITCHEN
1'-0"
2X WOOD FLAT FRAMING
@ CHASE WALL
2'-2 1/2"
FIELD VERIFY
MILLWORK CLOSET
2X4 WOOD FURRING ON
EXISTING FRAMING
REGENCY - CITY SERIES P/N: CB60E
GAS FIREPLACE, INSTALL PER
MANUFACTURER'S INSTRUCTIONS,
VENT THROUGH EXISTING CHIMNEY
CONCRETE PAVER PATIO TO
MATCH EAST PATIO,
SKIP PAVERS AS REQUIRED
TO AVOID EXISTING
PLANTINGS & TREES
CONCRETE PAVER WALK
GENERAL NOTES:
1. INFILL REMOVED WINDOW, DOOR AND VENT LOCATIONS WITH WOOD FRAMING AND INSULATION
TO MATCH EXISTING. PROVIDE SIDING & PAINT TO MATCH EXISTING.
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
A1.0
GROUND LEVEL FLOOR PLAN
GROUND LEVEL FLOOR PLAN
1/4" = 1'-0"
1
A1.0
DE
1
2
3
4
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
2
A2.0
3
A2.0
2
A2.1
3
A2.1
MASTER BEDROOM
MASTER CLOSET
MASTER
BATHROOM
BALCONY
MILL-
WORK
DRESSER
MILLWORK
CLOSET
MILL-
WORK
DRESSER
W1 W4
N1
N2
E1
S2
6'-0"
2'-10 1/2"1"
3"
W5
GENERAL NOTES:
1. INFILL REMOVED WINDOW, DOOR AND VENT LOCATIONS WITH WOOD FRAMING AND INSULATION
TO MATCH EXISTING. PROVIDE SIDING & PAINT TO MATCH EXISTING.
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
A1.1
SECOND LEVEL FLOOR PLAN
SECOND LEVEL FLOOR PLAN
1/4" = 1'-0"
1
A1.1
ABCDEFG
1
2
3
4
5
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
OFFICE FRONT
PORCH
MINERS CABIN
POWDER
EN
T
R
Y
EGRESS WELL
STAIR
KITCHEN
DINING
HALLMUDROOMGARAGE
W2
W3
E2
MILLWORK
CEILING
@ 8'-6" AFF WITH
MIN. 22"X30"
REMOVABLE
ACCESS PANEL
L2L2
L2 L2
L1
L1
L1
L7
L10 L10
L1 L1
L1L1 L1 L1
L1L1
L6L6
D3
D3
D3
SM
L3
L1
L3
L6
D
F
L1
L6
L6
OUTLET @
MILLWORK BASE
OUTLET @
MILLWORK BASE
L1 L1
L1L1
L2L2 L2L2
L7
L7
L7 L7
D3
D
3
D
3
D
3
D
3
OUTLET @
WINE COOLER
L2
L4
L1 L1
L1
L1 L1
L1 L1 L1 L1
L7
L1 L1 L1 L1
D3
D3
OVENMW
L1
L7
L7
L5
L7
L2 L2L2
+60"L7
L7
+72"+72"+72"
D3
D3
D3
D3
OUTLET @
VENT
OUTLET @
COOKTOP
L6 IN COVE
@ HEADER
L7
D
DW DISP
ER1
ER1
L12
L12
D3
D3
L12 L12
ER2
ER3
ER3
WALL MOUNTED
FIXTURE, EXISTING
TO REMAIN
WALL MOUNTED
FIXTURE, EXISTING
TO REMAIN
NEW ELECTRIC
AWNING OVER
SLIDING DOOR
ER1
WALL MOUNTED
FIXTURE, EXISTING
TO REMAIN
SWITCH
SWITCH WITH DIMMER CONTROL
D
3
J
SM
3-WAY SWITCH
JAMB SWITCH
SNOWMELT CONTROLS
WP WATERPROOF ELECTRICAL OUTLET
FLOOR ELECTRICAL OUTLET
PS REMOTE POWER SUPPLY FOR LOW VOLTAGE
FIXTURE.
ELECTRICAL & LOW VOLTAGE NOTES ELECTRICAL LEGEND
DUPLEX ELECTRICAL OUTLET
QUAD ELECTRICAL OUTLET
220V ELECTRICAL OUTLET
SWITCHED DUPLEX ELECTRICAL OUTLET
ELECTRIC PANEL
ELECTRIC METER
HEIGHT ABOVE FINISHED FLOOR+42"
CABLE TV OUTLET
EXHAUST FAN
ALL ELECTRICAL WORK SHALL COMPLY WITH PART VIII - ELECTRICAL OF THE 2015 INTERNATIONAL
RESIDENTIAL CODE. IN THE EVENT OF CONFLICT BETWEEN THE DESIGN DOCUMENTS AND THE 2015
INTERNATIONAL RESIDENTIAL CODE, THE CODE SHALL PREVAIL. ELECTRICAL CONTRACTOR SHALL NOTIFY
ARCHITECT OF AND CONDITIONS THAT DO NOT COMPLY WITH SUCH CODES.
PROVIDE CODE MINIMUM ELECTRICAL OUTLETS THROUGHOUT. GENERAL AND ELECTRICAL
CONTRACTORS TO REVIEW & CONFIRM ALL LIGHTING CONTROL, ELECTRICAL OUTLET, AND LOW VOLTAGE
DEVICE BOX EXACT LOCATIONS WITH OWNERS VIA WALK-THRU MEETING PRIOR TO RUNNING ALL WIRING.
PROVIDE CONCEALED POP-UP OUTLETS AT KITCHEN ISLAND LOCATIONS
G.C. TO PROVIDE 2xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE AT NEW DATA
TELEPHONE/LOCATIONS. (ALLOWS FOR PHONE, INTERCOM, WIRELESS ACCESS POINT, LAN, ETC.)
G.C. TO PROVIDE 2xRG6 & 4xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE.AT NEW/FUTURE
TELEVISION LOCATIONS
ELECTRICAL FIXTURES AND DEVICES AS GRAPHICALLY INDICATED ON PLANS ARE INTENDED TO
ILLUSTRATE LAYOUT ONLY. LAYOUT OF RECESSED AND SURFACE MOUNTED CEILING FIXTURES ARE
GENERALLY CENTERED, ALIGNED, AND EQUALLY SPACED AS INDICATED ON PLANS. EXACT DIMENSIONS
ARE AVAILABLE UPON REQUEST FROM LIGHTING DESIGNER. ARCHITECT AND OWNER TO REVIEW
RECESSED FIXTURE LOCATIONS PRIOR TO CEILING FINISH INSTALLATION.
PROVIDE SMOKE & CO DETECTORS THROUGHOUT THE RESIDENCE AS REQ'D BY LOCAL CODE OFFICIAL.
PROVIDE ASSOCIATED SECURITY SYSTEM WITH MOTION SENSORS, GLASS BREAKS, WINDOW AND DOOR
SENSORS, FREEZE AND FLOOD SENSORS, GAS DETECTORS, SYSTEM KEYPAD, ETC.
LIGHTING AND OTHER NECESSARY LIGHTING FIXTURES TO BE SELECTED BY THE OWNER OR THE
OWNER'S REPRESENTATIVE UNLESS NOTED OTHERWISE.COUNTER AIR SWITCH
1.
2.
3.
4.
5.
6.
7.
SURFACE MONOPOINT LIGHT FIXTURE
PENDANT LIGHT FIXTURE
RECESSED CAN LIGHT FIXTURE
ADJUSTABLE RECESSED CAN LIGHT FIXTURE
LED 45° CHANNEL LIGHT FIXTURE
WALL MOUNTED LINEAR ART LIGHT FITURE
RECESSED LED LIGHT STRIP
WALL MOUNTED DOWN LIGHT FIXTURE
ADJUSTABLE RECESSED LED CAN
LIGHTING FIXTURES (INTERIOR)
L1
L2
L3
L4
L5
L6
QTY.HIGH EFFICACY
YES
SURFACE MOUNTED, ADJUSTABLE LED MONOPOINT
DECORATIVE LED PENDANT
DINING DECORATIVE LED PENDANT NO
WALL MOUNTED LINEAR ART LED FIXTURE
YES
NO
YES
RECESSED / COVE LINEAR LED FIXTURE YES
L7 YESLINEAR LED CABINET FIXTURE, HINGE SWITCH
(SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.)
L8 DECORATIVE LED PENDANT
L9 DECORATIVE LED PENDANT NO
DESCRIPTIONTAG
NO
WALL MOUNTED LED DOWN LIGHT, DARK SKY COMPLIANT, REFER TO EXTERIOR ELEVATIONS
LIGHTING FIXTURES (EXTERIOR)
L12
QTY.HIGH EFFICACY
YES
(SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.)
DESCRIPTIONTAG
L10 NOLED WALL LAMP
L11 WET LOCATION ADJUSTABLE LED CAN YES
54
8
2
1
1
9
16
1
2
2
1 LIGHTING NOTES:
1. REFER TO PLANS & ELECTRICAL LEGEND FOR
ADJUSTABLE/FIXED RECESSED CAN LIGHT FIXTURE
LOCATIONS.
2. CONTRACTOR TO CONFIRM FIXTURE QUANTITIES PRIOR TO
ORDERING.
HIGH EFFICACY LIGHTING
CALCULATION
MINIMUM REQUIRED PERCENTAGE OF
HIGH EFFICACY LIGHT FIXTURES:
TOTAL PROVIDED LIGHT FIXTURES:
TOTAL PROVIDED HIGH EFFICACY
LIGHT FIXTURES:
PERCENTAGE OF HIGH EFFICACY
LIGHT FIXTURES:
50%
103
95
95/103 = 92.2%
EXISTING TO REMAIN RECESSED LED CAN LIGHTER1 (E)2
5
EXISTING RELOCATED FLOOD LIGHTER2 YES1
EXISTING TO REMAIN WALL MOUNTED DOWN LIGHTER3 (E)3
NEW/MODIFIED FIXTURES ONLY
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
A1.2
GROUND LEVEL
REFLECTED CEILING PLAN
GROUND LEVEL REFLECTED CEILING PLAN
1/4" = 1'-0"
1
A1.2
DE
1
2
3
4
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
MASTER BEDROOM
MASTER CLOSET
MASTER BATHROOM
10" WIDE DRYWALL SOFFIT ON
WOOD FURRING @ 9'-6" AFF
PROVIDE FLUSH GYP. BOARD ON
WOOD FRAMING ACCESS PANEL
WITH ALUMINUM REGLET TRIM,
MINIMUM 22"X30"
8'-0" AFF
EXISTING CEILING
5/8" GYP. BOARD ON WOOD
FRAMING CEILING @ 8'-0 AFF
INDICATED BY HATCH
D3
D D
D3
D
F
L7
L6
L1
L1L1
L1
L1
L1 L1
L1 L1
L1
L1
L1 L1 L1 L1 L1
L1
L9 L9
L8
L11
L6
+60"+60"
L1 L1
L6
F
L1 L1 L1 L1
L12
ER3
WALL MOUNTED
FIXTURE, EXISTING
TO REMAIN
D
L7L7L7
D
D
SWITCH
SWITCH WITH DIMMER CONTROL
D
3
J
SM
3-WAY SWITCH
JAMB SWITCH
SNOWMELT CONTROLS
WP WATERPROOF ELECTRICAL OUTLET
FLOOR ELECTRICAL OUTLET
PS REMOTE POWER SUPPLY FOR LOW VOLTAGE
FIXTURE.
ELECTRICAL & LOW VOLTAGE NOTES ELECTRICAL LEGEND
DUPLEX ELECTRICAL OUTLET
QUAD ELECTRICAL OUTLET
220V ELECTRICAL OUTLET
SWITCHED DUPLEX ELECTRICAL OUTLET
ELECTRIC PANEL
ELECTRIC METER
HEIGHT ABOVE FINISHED FLOOR+42"
CABLE TV OUTLET
EXHAUST FAN
ALL ELECTRICAL WORK SHALL COMPLY WITH PART VIII - ELECTRICAL OF THE 2015 INTERNATIONAL
RESIDENTIAL CODE. IN THE EVENT OF CONFLICT BETWEEN THE DESIGN DOCUMENTS AND THE 2015
INTERNATIONAL RESIDENTIAL CODE, THE CODE SHALL PREVAIL. ELECTRICAL CONTRACTOR SHALL NOTIFY
ARCHITECT OF AND CONDITIONS THAT DO NOT COMPLY WITH SUCH CODES.
PROVIDE CODE MINIMUM ELECTRICAL OUTLETS THROUGHOUT. GENERAL AND ELECTRICAL
CONTRACTORS TO REVIEW & CONFIRM ALL LIGHTING CONTROL, ELECTRICAL OUTLET, AND LOW VOLTAGE
DEVICE BOX EXACT LOCATIONS WITH OWNERS VIA WALK-THRU MEETING PRIOR TO RUNNING ALL WIRING.
PROVIDE CONCEALED POP-UP OUTLETS AT KITCHEN ISLAND LOCATIONS
G.C. TO PROVIDE 2xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE AT NEW DATA
TELEPHONE/LOCATIONS. (ALLOWS FOR PHONE, INTERCOM, WIRELESS ACCESS POINT, LAN, ETC.)
G.C. TO PROVIDE 2xRG6 & 4xCat.5e FROM A/V HEAD END + STANDARD COVER PLATE.AT NEW/FUTURE
TELEVISION LOCATIONS
ELECTRICAL FIXTURES AND DEVICES AS GRAPHICALLY INDICATED ON PLANS ARE INTENDED TO
ILLUSTRATE LAYOUT ONLY. LAYOUT OF RECESSED AND SURFACE MOUNTED CEILING FIXTURES ARE
GENERALLY CENTERED, ALIGNED, AND EQUALLY SPACED AS INDICATED ON PLANS. EXACT DIMENSIONS
ARE AVAILABLE UPON REQUEST FROM LIGHTING DESIGNER. ARCHITECT AND OWNER TO REVIEW
RECESSED FIXTURE LOCATIONS PRIOR TO CEILING FINISH INSTALLATION.
PROVIDE SMOKE & CO DETECTORS THROUGHOUT THE RESIDENCE AS REQ'D BY LOCAL CODE OFFICIAL.
PROVIDE ASSOCIATED SECURITY SYSTEM WITH MOTION SENSORS, GLASS BREAKS, WINDOW AND DOOR
SENSORS, FREEZE AND FLOOD SENSORS, GAS DETECTORS, SYSTEM KEYPAD, ETC.
LIGHTING AND OTHER NECESSARY LIGHTING FIXTURES TO BE SELECTED BY THE OWNER OR THE
OWNER'S REPRESENTATIVE UNLESS NOTED OTHERWISE.COUNTER AIR SWITCH
1.
2.
3.
4.
5.
6.
7.
SURFACE MONOPOINT LIGHT FIXTURE
PENDANT LIGHT FIXTURE
RECESSED CAN LIGHT FIXTURE
ADJUSTABLE RECESSED CAN LIGHT FIXTURE
LED 45° CHANNEL LIGHT FIXTURE
WALL MOUNTED LINEAR ART LIGHT FITURE
RECESSED LED LIGHT STRIP
WALL MOUNTED DOWN LIGHT FIXTURE
ADJUSTABLE RECESSED LED CAN
LIGHTING FIXTURES (INTERIOR)
L1
L2
L3
L4
L5
L6
QTY.HIGH EFFICACY
YES
SURFACE MOUNTED, ADJUSTABLE LED MONOPOINT
DECORATIVE LED PENDANT
DINING DECORATIVE LED PENDANT NO
WALL MOUNTED LINEAR ART LED FIXTURE
YES
NO
YES
RECESSED / COVE LINEAR LED FIXTURE YES
L7 YESLINEAR LED CABINET FIXTURE, HINGE SWITCH
(SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.)
L8 DECORATIVE LED PENDANT
L9 DECORATIVE LED PENDANT NO
DESCRIPTIONTAG
NO
WALL MOUNTED LED DOWN LIGHT, DARK SKY COMPLIANT, REFER TO EXTERIOR ELEVATIONS
LIGHTING FIXTURES (EXTERIOR)
L12
QTY.HIGH EFFICACY
YES
(SEE FIXTURE CUT SHEETS FOR MANUFACTURER INFO.)
DESCRIPTIONTAG
L10 NOLED WALL LAMP
L11 WET LOCATION ADJUSTABLE LED CAN YES
54
8
2
1
1
9
16
1
2
2
1 LIGHTING NOTES:
1. REFER TO PLANS & ELECTRICAL LEGEND FOR
ADJUSTABLE/FIXED RECESSED CAN LIGHT FIXTURE
LOCATIONS.
2. CONTRACTOR TO CONFIRM FIXTURE QUANTITIES PRIOR TO
ORDERING.
HIGH EFFICACY LIGHTING
CALCULATION
MINIMUM REQUIRED PERCENTAGE OF
HIGH EFFICACY LIGHT FIXTURES:
TOTAL PROVIDED LIGHT FIXTURES:
TOTAL PROVIDED HIGH EFFICACY
LIGHT FIXTURES:
PERCENTAGE OF HIGH EFFICACY
LIGHT FIXTURES:
50%
103
95
95/103 = 92.2%
EXISTING TO REMAIN RECESSED LED CAN LIGHTER1 (E)2
5
EXISTING RELOCATED FLOOD LIGHTER2 YES1
EXISTING TO REMAIN WALL MOUNTED DOWN LIGHTER3 (E)3
NEW/MODIFIED FIXTURES ONLY
WE
I
S
S
R
E
S
I
D
E
N
C
E
52
3
W
E
S
T
S
M
U
G
G
L
E
R
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
11
1
H
A
A
B
C
As
p
e
n
,
C
O
8
1
6
1
1
97
0
.
9
4
8
.
6
7
0
9
ba
r
r
y
.
g
e
r
e
b
@
b
g
a
d
a
s
p
e
n
.
c
o
m
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
CD SET
2/5/21
NO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N
A1.3
SECOND LEVEL
REFLECTED CEILING PLAN
SECOND LEVEL REFLECTED CEILING PLAN
1/4" = 1'-0"
1
A1.3
east elevation
scale: 1/4" = 1'-0"3
AREA OF
PROPOSED
WORK
AREA OF
PROPOSED
WORK
AREA OF
PROPOSED
WORK BEYOND:
SEE 2/A2.0
NOTES:
1. INSULATION AT PROPOSED INFILL
AREAS TO MATCH EXISTING
2.INFILL WALL AT REMOVED
WINDOWS, PROVIDE SIDING
AND PAINT TO MATCH
EXISTING, TYP.
PROPOSED GAS APPLIANCE TO
VENT IN EXISTING MINERS
CABIN CHIMNEY IN EXISTING
VENT ENCLOSURE. NO
CHANGES TO MINER'S CABIN
EXTERIOR PROPOSED
N1
E1
E2
1
N3
N3
N2N2
L12
L12
ER2
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
2/5/21
A2.0
BUILDING ELEVATIONS
AREA OF
PROPOSED
WORK
RANGE VENT
AREA OF
PROPOSED
WORK BEYOND:
SEE 2/A2.1
AREA OF
PROPOSED
WORK
S1
W4 W1
W2
W3
NOTES:
1. INSULATION AT PROPOSED
INFILL AREAS TO MATCH
EXISTING
2.INFILL WALL AT REMOVED
WINDOWS, PROVIDE SIDING
AND PAINT TO MATCH
EXISTING, TYP.
PROVIDE FINISH TO
MATCH EXISTING
SIDING @ OUTDOOR
KITCHEN, FLASH TO
EXISTING BUILDING AS
REQUIRED, OUTDOOR
KITCHEN DOES NOT
TOUCH EXISTING
MINER'S CABIN
S2
W5
PROVIDE MIN 48" WIDE
SECTION OF
FIBER-CEMENT OR
EQUIVALENT
NON-COMBUSTIBLE
BOARD & BATTEN
FINISH MATERIAL
CENTERED BEHIND
GRILL UNIT
PROVIDE BLACK
ALUMINUM BRAKE
METAL TO MATCH
CORNER WINDOW
DETAIL
PROVIDE TRIM TO
MATCH
PROVIDE TRIM
TO MATCH
PROVIDE TRIM TO
MATCH
L12L12
ER3 ER3
ER3
L12
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
2/5/21
A2.1
BUILDING ELEVATIONS
E1
WINDOW MATERIAL OPERATION
WINDOW SCHEDULE
UNIT SIZE (W X H)U-VALUEMANUFACTURER NOTES
E2
S1
W1
W2
W3
W4
N1
N2
N3
TBD
TBD
TBD
66"X18"
84"X12"
60"X72"
24"X18"
144"X18"
84"X12"
24"X18"
60"X75"
24"X42"
84"X96"
CLAD/WOOD
CLAD/WOOD
CLAD/WOOD
AWNING
FIXED GLASS
FIXED GLASS
FIXED GLASS
FIXED GLASS
FIXED GLASS
SLIDING DOOR XO
FIXED GLASS
SLIDING DOOR OX
0.28 MAX.
0.28 MAX.
0.28 MAX.
HEAD HEIGHT = 8'-0" AFF, DIRECT SET INSULATED GLASS
HEAD HEIGHT AS HIGH AS POSSIBLE, RE: STRUCTURAL
SAFETY GLAZING, MATCH EXISTING HEAD HEIGHT
PELLA ARCHITECTURAL CONTEMPORARY SERIES, SAFETY GLAZING
PELLA ARCHITECTURAL CONTEMPORARY SERIES, SAFETY GLAZING
DOOR LOCATION UNIT SIZE MATERIAL
CLAD/WOOD
OPERATION
SLIDING DOOR OXX
HARDWARE
EXTERIOR DOOR SCHEDULE
NOTES
126"x96"
THICKNESS
1-3/4"ENTRY
NOTES:
1. CONTRACTOR TO CONFIRM DOOR SIZES AND DETAILS WITH ARCHITECT PRIOR TO ORDERING
2. BEAR RESISTANT DOOR HARDWARE
3. U-VALUE: .28 MAXIMUM
4. DOOR CLADDING COLOR TO MATCH EXISTING
PELLA ARCHITECTURAL CONTEMPORARY SERIES, LOCATE
IN EXISTING OPENINGPATIO ENTRY
8'
-
0
"
10'-6"
TBD CLAD/WOOD 0.28 MAX.
TBD CLAD/WOOD FIXED GLASS 0.28 MAX.
HEAD HEIGHT = 8'-0" AFF, DIRECT SET INSULATED GLASS
WINDOW SCHEDULE NOTES:
- CONTRACTOR TO CONFIRM WINDOW SIZE AND DETAILS WITH ARCHITECT PRIOR TO ORDERING.
- ALL EXTERIOR CLADDING COLOR SHALL MATCH EXISTING.
0.28 MAX.
0.28 MAX.
0.28 MAX.
0.28 MAX.
0.28 MAX.
CLAD/WOOD
CLAD/WOOD
CLAD/WOOD
CLAD/WOOD
CLAD/WOOD
TBD
TBD
TBD
TBD
TBD
N1 N2
N3 E1 E2
S1 W4W1W2
5'-0"2'-0"7'-0"5'-6"7'-0"
5'-0"2'-0"
12'-0"
EQ.EQ.EQ.7'-0"2'-0"
1'
-
6
"
1'
-
0
"
1'
-
6
"
1'
-
6
"
6'
-
0
"
1'
-
0
"
1'
-
6
"
8'
-
0
"
F
I
E
L
D
V
E
R
I
F
Y
3'
-
6
"
6'
-
3
"
F
I
E
L
D
V
E
R
I
F
Y
1
1
RAILING AT NORTH EDGE OF
EXISTING STAIR.
RAILING AT NORTH EDGE OF
EXISTING STAIR TERMINATES
BEYOND MECH CHASE WALL
ON LANDING
ROUND WOOD CAP
TO MATCH EXISTING <4"
<6"
RAILING TO MATCH OPPOSITE
SIDE OF STAIR WHERE
CABINET TO BE REMOVED
3'
-
0
"
M
I
N
.
FI
E
L
D
V
E
R
I
F
Y
E
X
I
S
T
I
N
G
R
.
O
.
STAIR RAILING
3/4" = 1'-0"
1
A3.0MINER'S CABIN GAS APPLIANCE
1/4" = 1'-0"
2
A3.0
DOOR ELEVATIONS (VIEW FROM EXTERIOR)
1/4" = 1'-0"A3.0
WINDOW ELEVATIONS (VIEW FROM EXTERIOR)
1/4" = 1'-0"
4
A3.0
EXISTING WOOD
TREADS
STEEL ROUND BARS,
TO MATCH EXISTING
STEEL PLATE POSTS TO MATCH
EXISTING
MINER'S CABIN GAS FIREPLACE APPLIANCE
1/4" = 1'-0"
2
A3.0
3
HEAD HEIGHT = 8'-0" AFF
S2 TBD 60"X60"CLAD/WOOD FIXED GLASS 0.28 MAX.MATCH EXISTING HEAD HEIGHT
MATCH EXISTING HEAD HEIGHT, MOTORIZED OPERATION
S2
5'-0"
5'
-
0
"
W5 66"X18"AWNING MATCH EXISTING ADJACENT WINDOW HEAD HEIGHTS, MOTORIZED OPERATION0.28 MAX.CLAD/WOODTBD
MATCH EXISTING HEAD HEIGHT
MATCH EXISTING HEAD HEIGHT
W3 W5
5'-6"
1'
-
6
"
U-VALUE
0.28 MAX.
RAILING AT NORTH EDGE OF
EXISTING STAIR.
RAILING AT NORTH EDGE OF
EXISTING STAIR TERMINATES
BEYOND MECH CHASE WALL
ON LANDING
ROUND WOOD CAP
TO MATCH EXISTING <4"
<6"
RAILING TO MATCH OPPOSITE
SIDE OF STAIR WHERE
CABINET TO BE REMOVED
3'
-
0
"
M
I
N
.
STAIR RAILING
3/4" = 1'-0"
1
A3.0
EXISTING WOOD
TREADS
STEEL ROUND BARS,
TO MATCH EXISTING
STEEL PLATE POSTS TO MATCH
EXISTING
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
2/5/21
A3.0
SCHEDULES & DETAILS
bg
AR
C
H
I
T
E
C
T
U
R
E
&
D
E
S
I
G
N
2/5/21
A4.0
SPECIFICATIONS
SCALE: NOT TO SCALE
OUTDOOR GRILL1
A4.0SCALE: NOT TO SCALE
EXTERIOR LIGHT FIXTURE2
A4.0