Pedestal Deck Assembly.508 E Cooper Ave.20210723
2 TYPICAL TERRACE DECK PAVER ASSEMBLY DETAIL 3" = 1'-0" REMOVE DRAINAGE MAT & WATERPROOFING MEMBRANE REMOVE LIGHTWEIGHT CONC.TOPPING SLAB REMOVE STONE PAVERS OVER GROUT BED REMOVE TAPERED RIGID INSULATION; THICKNESS VARIES REMOVE PLYWOOD SHEATHING DEMO REPAIR COMPOSITE CONCRETE SLAB TO REMAIN ADJUSTABLE PEDESTALS AT EACH JOINT INTERSECTION SUPPLY / RETURN MANIFOLD SET INTO INSULATION AS REQUIRED VA R I E S (7 " A T H I G H E S T E L E V A T I O N ) COMPOSITE CONCRETE SLAB TO REMAIN DRAINAGE MAT HOT FLUID-APPLIED WATERPROOFING, REFER TO SHEETS A5.0 & A5.1 FOR TYPICAL REQUIREMENTS THERMAPANEL INLET/OUTLET, TYP. RIGID INSULATION, TYP. (2) LAYERS FACTORY APPLIED EPS INSULATION, TYP. 7 7 16 " (N O S L O P E ) 312" 23 8" 13 16 " 3 8" T.O.F.F. APPROX. 7 7 16 " ABOVE CONCRETE THERMAHEXX TRAY 24"x24" NOMINAL PAVER, TYP. BISON PAVER SUPPORT TRAY A4.0 4 TYP. 1 TYPICAL EXTERIOR WALL WITH ZINC CLADDING ASSEMBLY DETAILS 3" = 1'-0" 1B - REPAIR AT STUD FRAMED WALL 5/8"DENS GLASS TO REMAIN 5 8" GYPSUM BOARD TO REMAIN COLD FORMED METAL FRAMING TO REMAIN 4" SPRAY FOAM INSULATION W/ IGNITION BARRIER TO REMAIN 1" RIGID INSULATION W/ 1/2" NAIL BASE TO REMAIN EXISTING 12" PLYWOOD SHEATHING TO REMAIN NEW HAT CHANNELS AND ZINC SIDING. FASTEN HAT CHANNELS OVER VERTICAL STRIPS OF BUTYL SELF-ADHERED FLASHING NEW SELF-ADHERED MEMBRANE * * * * * * REPLACE DAMAGED MATERIAL AS NEEDED. MATCH EXISTING. * 1A - REPAIR AT CMU WALL EXISTING CMU TO REMAIN. REPAIR AS REQUIRED TO MEET MANUFACTURER'S SUBSTRATE REQUIREMENTS. CONDUCT ADHESION TESTING TO VERIFY PRIMER REQUIREMENTS. NEW HAT CHANNELS AND ZINC SIDING. FASTEN HAT CHANNELS OVER VERTICAL STRIPS OF BUTYL SELF-ADHERED FLASHING NEW SELF-ADHERED MEMBRANE 1C - ZINC SIDING AT INSIDE CORNER INSIDE CORNER FLASHING INTERLOCKING METAL PANEL FASTENED TO HAT CHANNEL FASTEN HAT CHANNELS OVER VERTICAL STRIP OF BUTYL SELF-ADHERED FLASHING, TYP. EXISTING/REPAIRED/NEW BACKUP WALL 1D - ZINC SIDING AT INSIDE CORNER EXISTING/REPAIRED/NEW BACKUP WALL FASTEN HAT CHANNELS OVER VERTICAL STRIP OF BUTYL SELF-ADHERED FLASHING, TYP. INTERLOCKING METAL PANEL FASTENED TO HAT CHANNEL OUTSIDE CORNER FLASHING DEMO 3 TYPICAL TERRACE DECK DRAIN ASSEMBLY 3" = 1'-0" REPAIR REMOVE EXISTING DRAIN BODY INSTALL NEW ZURN Z-181-FS (FLAT STRAINER) OR JOSAM 24500-35 (FLAT GRATE) DRAIN SUMP EXISTING CONCRETE DECK AROUND DRAINS (1" DEEP AND 18"Ø OUT FROM DRAIN BODY), TYP. RIGID INSULATION, TYP. (2) LAYERS DRAINAGE MAT ADJUSTABLE PEDESTALS AT EACH JOINT INTERSECTION SUPPLY / RETURN MANIFOLD SET INTO INSULATION AS REQUIRED THERMAPANEL INLET/OUTLET, TYP. 7 7 16 " (N O S L O P E ) 312" 23 8" 13 16 " 3 8" T.O.F.F. REMOVE DRAINAGE MAT & WATERPROOFING MEMBRANE REMOVE LIGHTWEIGHT CONC.TOPPING SLAB REMOVE STONE PAVERS REMOVE TAPERED RIGID INSULATION; THICKNESS VARIES REMOVE PLYWOOD SHEATHING COMPOSITE CONCRETE SLAB TO REMAIN FACTORY APPLIED EPS INSULATION, TYP. APPROX. 7 7 16 " ABOVE CONCRETE COMPOSITE CONCRETE SLAB TO REMAIN HOT FLUID-APPLIED WATERPROOFING, REFER TO SHEETS A5.0 & A5.1 FOR TYPICAL REQUIREMENTS A4.0 4 SIM. BISON SPLINE WITH TWO SPACER TABS ~ SECURELY FASTEN THROUGH SPLINE, BISON SPACER, AND THERMAHEXX TRAY SECUREMENT PLATE INTO TOP OF PEDESTAL 4 PEDESTAL ASSEMBLY NOT TO SCALE BISON PAVER ADHESIVELY SECURED TO SUPPORT TRAY BISON PAVER SUPPORT TRAY THERMAHEXX TRAY THERMAHEXX TRAY SECUREMENT PLATE WITH 0 PAVER SPACERS (NOT DIRECTLY FASTENED) BISON PAVER SPACER WITH TWO SPACER TABS (NOT DIRECTLY FASTENED) BISON PEDESTAL TYPICAL TERRACE ASSEMBLY DETAILS A4.0 TITLE: SHEET No.: CLIENT: PROJECT: SEAL: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A B C D E F DRAWN BY: REVIEWED BY: PROJECT MANAGER: ISSUE DATE: WJE PROJECT No.: SCALE:AS NOTED No. FV / APH FWB / APH / SER SER 06-14-2021 2019.8210.1 DATE DESCRIPTION 100% CONSTRUCTION DOCUMENTS06-14-2021 508 EAST COOPER RESIDENCE 508 East Cooper Ave. Aspen, Colorado WJM 508, LLC 101 South Mill Street Suite 200 Aspen, Colorado 81611 Contact: Mr. Kenneth Citron Ph. (970) 925-8700 PL O T T E D B Y : Sc h u m a n , B r a d ( 7/ 2 3 / 2 0 2 1 - 4: 0 1 P M ) LA S T S A V E D B Y : BS C H U M (7/ 2 0 / 2 0 2 1 - 3 : 4 9 P M ) FI L E L O C A T I O N : P: \ 2 0 1 9 \ 2 0 1 9 . 8 x x x \ 2 0 1 9 . 8 2 1 0 . 1 - 5 0 8 E A S T C O O P E R S T R E E T - R E P A I R D O C U M E N T S ( S E R ) \ D r a w i n g s \ 1 W o r k i n g S e t s © Co p y r i g h t 2 0 2 1 . A L L R I G H T S R E S E R V E D . N O P A R T O F T H I S D O C U M E N T M A Y B E R E P R O D U C E D I N A N Y F O R M O R B Y A N Y M E A N S W I T H O U T PE R M I S S I O N F R O M W I S S , J A N N E Y , E L S T N E R A S S O C I A T E S , I N C . ( W J E ) . W J E D I S C L A I M S A N Y R E S P O N S I B I L I T Y F O R I T S U N A U T H O R I Z E D U S E . WJE ENGINEERS ARCHITECTS MATERIALS SCIENTISTS Wiss, Janney, Elstner Associates, Inc. 3609 S. Wadsworth Blvd. #400 Lakewood, CO 80235 Phone: 303.914.4300 CITY OF ASPEN REGISTRATION No: 12586 Headquarters & Laboratories: Northbrook, Illinois Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York Princeton | San Francisco | Seattle | South Florida | Washington, D.C. 1 1 1 07-23-2021 ASI # 21