Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Zoning.508 East Cooper Ave.20210812
DN UP UP UP DN NOT IN SCOPE GUEST BEDROOM GUEST BATHROOM KITCHEN LIVING ROOM LEVEL 3 MAIN TERRACE 300 DINING ROOM 301 302 304 303 LEVEL THREE GUEST TERRACE 305 ELEVATOR DN UP UP ELEVATOR PLANTER UTILITY CLOSET MASTER BATHROOM MASTER BEDROOM DN MASTER FOYER LEVEL 4 ROCK GARDEN 405 400 401403 402 NOT IN SCOPE LEVEL 4 TERRACE 404 ELEVATOR OVER-RUN HOT TUB LOWER PLANTER BED NOT IN SCOPE DN SLOPE DN ROOF TERRACE 500 UPPER PLANTER BED LCE 191 SF UNIT 201 1631 SF LCE 113 SF GCE Mechanical GCE Stairs UNIT 201 49 SF GCE Mechanical GCE Stairs LCE 338 SF LCE 53 SF LCE 273 SF GCE GCE GCE LCE 519 SF LCE 169 SF UNIT 201 957 SF UNIT 201 49 SF 302 NOT IN SCOPE GUEST BEDROOM 2 GUEST BEDROOM 1 202 201 DN UP UP DN UP FAMILY ROOM LAUNDRY CLOSET CLOSET LEVEL 2 TERRACE 203 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW LCE 47 SF HATCH LEGEND GCE - GENERAL COMMON ELEMENT AREA GCE - GENERAL COMMON ELEMENT AREA NOT IN SCOPE LCE - LIMITED COMMON ELEMENT AREA LCE - LIMITED COMMON ELEMENT AREA NOT IN SCOPE AREA NOT IN SCOPE EXISTING AND PROPOSED PLANTERS ZONE PLAN EXISTING Z1.0 TITLE: SHEET No.: CLIENT: PROJECT: SEAL: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A B C D E F DRAWN BY: REVIEWED BY: PROJECT MANAGER: ISSUE DATE: WJE PROJECT No.: SCALE:AS NOTED No. BRS / CRS SER SER 08-12-2021 2019.8210.2 DATE DESCRIPTION 508 EAST COOPER RESIDENCE 508 East Cooper Ave. Aspen, Colorado WJM 508, LLC 101 South Mill Street Suite 200 Aspen, Colorado 81611 Contact: Mr. Kenneth Citron Ph. (970) 925-8700 PL O T T E D B Y : Sc h u e t t e , C h r i s ( 8/ 1 2 / 2 0 2 1 - 2: 5 0 P M ) LA S T S A V E D B Y : CS C H U E (8/ 1 2 / 2 0 2 1 - 1 2 : 4 9 P M ) FI L E L O C A T I O N : P: \ 2 0 1 9 \ 2 0 1 9 . 8 x x x \ 2 0 1 9 . 8 2 1 0 . 1 - 5 0 8 E A S T C O O P E R S T R E E T - R E P A I R D O C U M E N T S ( S E R ) \ D r a w i n g s \ 1 W o r k i n g S e t s © Co p y r i g h t 2 0 2 1 . A L L R I G H T S R E S E R V E D . N O P A R T O F T H I S D O C U M E N T M A Y B E R E P R O D U C E D I N A N Y F O R M O R B Y A N Y M E A N S W I T H O U T PE R M I S S I O N F R O M W I S S , J A N N E Y , E L S T N E R A S S O C I A T E S , I N C . ( W J E ) . W J E D I S C L A I M S A N Y R E S P O N S I B I L I T Y F O R I T S U N A U T H O R I Z E D U S E . WJE ENGINEERS ARCHITECTS MATERIALS SCIENTISTS Wiss, Janney, Elstner Associates, Inc. 3609 S. Wadsworth Blvd. #400 Lakewood, CO 80235 Phone: 303.914.4300 CITY OF ASPEN REGISTRATION No: 12586 Headquarters & Laboratories: Northbrook, Illinois Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York Princeton | San Francisco | Seattle | South Florida | Washington, D.C. ZONING REVIEW DOCUMENTS08-12-20213SCALE: 3/16" = 1'-0" FOURTH FLOOR PLAN VIEW - EXISTING1SCALE: 3/16" = 1'-0" SECOND FLOOR PLAN VIEW - EXISTING 4 SCALE: 3/16" = 1'-0" FIFTH FLOOR (ROOF LEVEL) PLAN VIEW - EXISTING N N N INTERIOR COLUMNS (STRUCTURAL ELEMENTS) AND ATTACHED BUILDING UTILITIES, IF ANY, WITHIN A CONDOMINIUM UNIT OR LCE BOUNDARY ARE GENERAL COMMON ELEMENTS. THESE ELEMENTS, IF ANY, AND ANY INTERIOR WALLS HAVE NOT BEEN EXCLUDED FROM THE UNIT SQUARE FOOT CALCULATIONS. AREA TABLE (SF) LCE UNIT USAGE UNIT 201 1,933 4,415 RESIDENTIAL NOTES: 1.PLAN VIEWS ARE FROM ARCHITECTURAL DRAWINGS TO ILLUSTRATE EXTERIOR FLOOR AREAS EFFECTED BY REPAIR PROJECT. 2.UNIT DIMENSIONS ARE FROM UNFINISHED PERIMETER WALL SURFACE TO UNFINISHED PERIMETER WALL SURFACE; CEILING DIMENSIONS ARE FROM UNFINISHED FLOOR TO UNFINISHED DRYWALL CEILING OR LOWEST CEILING STRUCTURAL ELEMENT. 3.ALL LCE AREAS ASSOCIATED WITH UNIT 201 FINISHED FACADE ON THE EXTERIOR AND FINISHED DRYWALL TO FINISHED DRYWALL INSIDE, UNLESS NOTED OTHERWISE. 4.ALL AREAS OUTSIDE THE INDIVIDUAL CONDOMINIUM UNITS ARE GENERAL COMMON ELEMENTS (GCE) OF THE COOPER STREET CONDOMINIUMS UNLESS IDENTIFIED AS A LIMITED COMMON ELEMENT (LCE) RESERVED FOR USE BY FEWER THAN ALL THE OWNERS OF THE INDIVIDUAL UNITS. THE TERM GCE IS INTENDED TO INCORPORATE AND NOT LIMIT THE COMPONENTS INCLUDED IN THE DEFINITION OF "COMMON ELEMENTS" UNDER THE DECLARATION, UNLESS OTHERWISE IDENTIFIED AS LCE. 5.WINDOWS AND DOOR FRAMES ARE PART OF THE UNIT AND NOT CONSIDERED GCE. 6.EASEMENT FOR EMERGENCY ACCESS AS SET FORTH IN SECTION 4.1(a) OF THE COMMON DECLARATION. 7.ELEVATORS WITH UNITS ARE DESCRIBED AS BOUNDED BY THE INTERIOR WALL OF THE ELEVATOR SHAFT FROM THE FLOOR ELEVATION OF THE LOWEST ACCESS LEVEL TO THE CEILING ELEVATION OF THE HIGHEST ACCESS LEVEL. THE FLOOR AREA OF THE INTERIOR ELEVATOR SHAFT IS ADDED TO THE UNIT AREA ON EACH LEVEL THE ELEVATOR ACCESS. 8.FOUNDATION WALL OPENING AS SET FORTH IN SECTION 3.1 OF THE CONDOMINIUM DECLARATION. 2 SCALE: 3/16" = 1'-0" THIRD FLOOR PLAN VIEW - EXISTING N DN UP UP UP DN NOT IN SCOPE GUEST BEDROOM GUEST BATHROOM KITCHEN LIVING ROOM LE V E L 3 MA I N T E R R A C E 300 DINING ROOM 301 304 303 305 ELEVATOR DN UP UP ELEVATOR PLANTER UTILITY CLOSET MASTER BATHROOM MASTER BEDROOM DN MASTER FOYER LEVEL 4 ROCK GARDEN 405 400 401403 402 NOT IN SCOPE LEVEL 4 TERRACE 404 ELEVATOR OVER-RUN HOT TUB NOT IN SCOPE DN SLOPE DN ROOF TERRACE 500 UNIT 201 1631 SF LCE 61 SF GCE Mechanical GCE Stairs UNIT 201 49 SF GCE Mechanical GCE Stairs LCE 322 SF LCE 53 SF LCE 273 SF GCE GCE GCE LCE 656 SF UNIT 201 957 SF UNIT 201 49 SF 30 2 PC484836 PC482436 PC484836 PC482436 LEVEL THREE GUEST TERRACE PC484836 PC 9 6 2 4 3 6 PC 9 6 2 4 3 6 PC 9 6 2 4 3 6 PC 4 8 2 4 3 6 PC242436 3.984 SF 15.984 SF 7.9743 SF 7.9743 SF 15.984 SF 15.984 SF 15 . 9 2 7 S F 15 . 9 2 7 S F 15 . 9 2 7 S F 7. 9 4 8 S F LCE 127 SF PC484836 15.984 SF PC 9 6 2 4 3 6 15 . 9 2 7 S F PC 9 6 2 4 3 6 15 . 9 2 7 S F NOT IN SCOPE GUEST BEDROOM 2 GUEST BEDROOM 1 202 201 DN UP UP DN UP FAMILY ROOM LAUNDRY CLOSET CLOSET LEVEL 2 TERRACE 203 OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW HATCH LEGEND GCE - GENERAL COMMON ELEMENT AREA GCE - GENERAL COMMON ELEMENT AREA NOT IN SCOPE LCE - LIMITED COMMON ELEMENT AREA LCE - LIMITED COMMON ELEMENT AREA NOT IN SCOPE AREA NOT IN SCOPE EXISTING AND PROPOSED PLANTERS ZONE PLAN PROPOSED Z1.1 TITLE: SHEET No.: CLIENT: PROJECT: SEAL: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 A B C D E F DRAWN BY: REVIEWED BY: PROJECT MANAGER: ISSUE DATE: WJE PROJECT No.: SCALE:AS NOTED No. BRS / CRS SER SER 08-12-2021 2019.8210.2 DATE DESCRIPTION 508 EAST COOPER RESIDENCE 508 East Cooper Ave. Aspen, Colorado WJM 508, LLC 101 South Mill Street Suite 200 Aspen, Colorado 81611 Contact: Mr. Kenneth Citron Ph. (970) 925-8700 PL O T T E D B Y : Sc h u e t t e , C h r i s ( 8/ 1 2 / 2 0 2 1 - 2: 5 0 P M ) LA S T S A V E D B Y : CS C H U E (8/ 1 2 / 2 0 2 1 - 1 2 : 4 9 P M ) FI L E L O C A T I O N : P: \ 2 0 1 9 \ 2 0 1 9 . 8 x x x \ 2 0 1 9 . 8 2 1 0 . 1 - 5 0 8 E A S T C O O P E R S T R E E T - R E P A I R D O C U M E N T S ( S E R ) \ D r a w i n g s \ 1 W o r k i n g S e t s © Co p y r i g h t 2 0 2 1 . A L L R I G H T S R E S E R V E D . N O P A R T O F T H I S D O C U M E N T M A Y B E R E P R O D U C E D I N A N Y F O R M O R B Y A N Y M E A N S W I T H O U T PE R M I S S I O N F R O M W I S S , J A N N E Y , E L S T N E R A S S O C I A T E S , I N C . ( W J E ) . W J E D I S C L A I M S A N Y R E S P O N S I B I L I T Y F O R I T S U N A U T H O R I Z E D U S E . WJE ENGINEERS ARCHITECTS MATERIALS SCIENTISTS Wiss, Janney, Elstner Associates, Inc. 3609 S. Wadsworth Blvd. #400 Lakewood, CO 80235 Phone: 303.914.4300 CITY OF ASPEN REGISTRATION No: 12586 Headquarters & Laboratories: Northbrook, Illinois Atlanta | Austin | Boston | Chicago | Cleveland | Dallas | Denver | Detroit Honolulu | Houston | Los Angeles | Minneapolis | New Haven | New York Princeton | San Francisco | Seattle | South Florida | Washington, D.C. ZONING REVIEW DOCUMENTS08-12-20213SCALE: 3/16" = 1'-0" FOURTH FLOOR PLAN VIEW - PROPOSED 2 SCALE: 3/16" = 1'-0" THIRD FLOOR PLAN VIEW - PROPOSED 1 SCALE: 3/16" = 1'-0" SECOND FLOOR PLAN VIEW - PROPOSED N N N INTERIOR COLUMNS (STRUCTURAL ELEMENTS) AND ATTACHED BUILDING UTILITIES, IF ANY, WITHIN A CONDOMINIUM UNIT OR LCE BOUNDARY ARE GENERAL COMMON ELEMENTS. THESE ELEMENTS, IF ANY, AND ANY INTERIOR WALLS HAVE NOT BEEN EXCLUDED FROM THE UNIT SQUARE FOOT CALCULATIONS. AREA TABLE (SF) LCE UNIT USAGE UNIT 201 1,933 4,415 RESIDENTIAL NOTES: 1.PLAN VIEWS ARE FROM ARCHITECTURAL DRAWINGS UPDATED TO ILLUSTRATE EXTERIOR FLOOR AREAS EFFECTED BY REPAIR PROJECT. 2.UNIT DIMENSIONS ARE FROM UNFINISHED PERIMETER WALL SURFACE TO UNFINISHED PERIMETER WALL SURFACE; CEILING DIMENSIONS ARE FROM UNFINISHED FLOOR TO UNFINISHED DRYWALL CEILING OR LOWEST CEILING STRUCTURAL ELEMENT. 3.ALL LCE AREAS ASSOCIATED WITH UNIT 201 FINISHED FACADE ON THE EXTERIOR AND FINISHED DRYWALL TO FINISHED DRYWALL INSIDE, UNLESS NOTED OTHERWISE. 4.ALL AREAS OUTSIDE THE INDIVIDUAL CONDOMINIUM UNITS ARE GENERAL COMMON ELEMENTS (GCE) OF THE COOPER STREET CONDOMINIUMS UNLESS IDENTIFIED AS A LIMITED COMMON ELEMENT (LCE) RESERVED FOR USE BY FEWER THAN ALL THE OWNERS OF THE INDIVIDUAL UNITS. THE TERM GCE IS INTENDED TO INCORPORATE AND NOT LIMIT THE COMPONENTS INCLUDED IN THE DEFINITION OF "COMMON ELEMENTS" UNDER THE DECLARATION, UNLESS OTHERWISE IDENTIFIED AS LCE. 5.WINDOWS AND DOOR FRAMES ARE PART OF THE UNIT AND NOT CONSIDERED GCE. 6.EASEMENT FOR EMERGENCY ACCESS AS SET FORTH IN SECTION 4.1(a) OF THE COMMON DECLARATION. 7.ELEVATORS WITH UNITS ARE DESCRIBED AS BOUNDED BY THE INTERIOR WALL OF THE ELEVATOR SHAFT FROM THE FLOOR ELEVATION OF THE LOWEST ACCESS LEVEL TO THE CEILING ELEVATION OF THE HIGHEST ACCESS LEVEL. THE FLOOR AREA OF THE INTERIOR ELEVATOR SHAFT IS ADDED TO THE UNIT AREA ON EACH LEVEL THE ELEVATOR ACCESS. 8.FOUNDATION WALL OPENING AS SET FORTH IN SECTION 3.1 OF THE CONDOMINIUM DECLARATION. CALCULATION TABLES 4 SCALE: 3/16" = 1'-0" FIFTH FLOOR (ROOF LEVEL) PLAN VIEW - PROPOSED N