Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Exemption from Stream Margin Review_1020 E Hopkins Ave.
EXEMPTION FROM STREAM MARGIN REVIEW FOR 1020 E. Hopkins Ave. Address: 1020 E Hopkins Ave. Parcel ID: 2737-181-09-014 Zone District: R/MF 1020 E. Hopkins Ave. is located in the Stream Margin Review Area as established in Section 26.435.040 of the Aspen Land Use Code. Goldstein Gary L Lvg Trust No. 1, represented by Jeffrey Woodruff, has submitted a land use application for a remodel of an existing multi-family residence that proposes to add a non-street facing window to Unit 7 on the north facade of the building. The exterior scope of work includes the following items: Addition of a single window on the north facing façade of unit 7. The project qualifies for an exemption as the review criteria can be met: a) does not add more than 10% of the existing floor area, or more than 25% of areas exempt from floor area b) does not require the removal of any tree c) no portion of the project will be any closer to high water line than existing development d) does not fall outside of an existing building envelope e) will cause no increase to the amount of ground coverage within the 100-year flood plain The proposed scope of work includes alterations to windows on the north façade of the structure. Staff has reviewed the scope of work and has determined that it will have no impact on the Stream Margin. There is no ground/site work proposed as part of project, there are no impacts to trees or vegetation, and no concerns are raised related to impacts to stormwater run-off, or water quality. The scope of work identified above is therefore approved. However, if during the building permit process, the scope of work is amended, a new review will be required that may involve a more extensive analysis under the Stream Margin Exemption, or Stream Margin Review criteria. This approval does not constitute a site-specific development plan and will not be issued a development order. The approval does not convey a vested right and the approved project is subject to any changes to the Land Use Code prior to building permit submittal. Approved: _________________________________ _______________ Garrett Larimer Date Planner II, Community Development EXHIBIT A: Proposed Plans (attached) SHEET TITLE CONSULTANTS PROJECT NO: MODEL FILE: DRAWN BY: COPYRIGHT: SHEET 6 OF 58 A101 Jeffrey H. Woodruff Goldstein_09092020.pln Project No. 007 © 2020 /U s e r s / j e f f r e y w / D o c u m e n t s / C l o u d H i l l D e s i g n / A s p e n R e m o d e l / G o l d s t e i n _ 0 9 0 9 2 0 2 0 . p l n Parcel ID 273718109014 Account R004953 Jeffrey H. Woodruff Cloud Hill Design, LLC Snowmass, CO 81654 First Floor Existing/ Proposed & Assemblies Goldstein Residence Cloud Hill Design, LLC 1020 E Hopkins Unit #7 Aspen CO 81611 United States Brian Rossiter, P.E. Evolve Structural Carbondale, CO 81623 Jason Segal, Contractor Segal Development Carbondale, CO 81623 W2- Interior Wall W2- Exterior Wall R-33.5 5/8" LayerType X Gyp 2 x 4" Framing 5/8" LayerType X Gyp W1- Interior Wall 1/2" LayerType X Gyp 2 x 4" Framing 1/2" LayerType X Gyp Board and Batten Wood siding Poly Vapor Wrap 1 1/2" Ext Insulation (R-7.5) 1/2" Sheathing 2 x 6" Framing Fiberglass Bat (R-13) 2" Closed Cell (R-13) 1/2" Sheathing 5/8" LayerType X Gyp F1 Floor Assembly Carpet 3/8" Isolation Pad 3/4" Plywood Underlayment TJI R-30 Batt Insulation 5/8" Gyp F2 Floor Assembly tongue and groove wood floor 3/4" Plywood Underlayment TJI R-30 Batt Insulation 5/8" Gyp SCALE: 1' = 1'-0" Demolition_PlanSCALE: 1/4" = 1'-0" Code Information SHEET TITLE CONSULTANTS PROJECT NO: MODEL FILE: DRAWN BY: COPYRIGHT: SHEET 7 OF 58 A102 Jeffrey H. Woodruff Goldstein_09092020.pln Project No. 007 © 2020 /U s e r s / j e f f r e y w / D o c u m e n t s / C l o u d H i l l D e s i g n / A s p e n R e m o d e l / G o l d s t e i n _ 0 9 0 9 2 0 2 0 . p l n Parcel ID 273718109014 Account R004953 Jeffrey H. Woodruff Cloud Hill Design, LLC Snowmass, CO 81654 First Floor Plan Goldstein Residence Cloud Hill Design, LLC 1020 E Hopkins Unit #7 Aspen CO 81611 United States Brian Rossiter, P.E. Evolve Structural Carbondale, CO 81623 Jason Segal, Contractor Segal Development Carbondale, CO 81623 HW 905 sq ft entry closet to be removed no change to structure 3x LVL added, window header, as per structural engineer existing 8 x 10" beam above, bottom @7'-0" 42"h x 32"w, new window match opening of dr sill @ + 3'-3" head + 7'-3" sill @ + 10" head + 7'-4"note: 42" to bottom of bottom rod, 79" to top rod and shelf above 4" shelf no change to luminaire; height, lamp, etc. unchanged new faucet, no change in gpm no change to bath #1 no change to bath #2 shared wall (hallway/unit) shared wall (hallway/unit), interior walls to be replaced with type-x 5/8" drywall (asbestos) wood floor wood floor carpet floor north balcony south balcony diningkitchen living room clg @ 7'-11" typ office/bedroom bedroom bath #2elec. w/d fire place common hallway (unit/ building relationship, end unit) 4 8 16 32 bath #1 client to supply RCP to electrician, largely surface mounted fixtures (typ.) N SCALE: 1/4" = 1'-0"1 First Floor SCALE: 1:1.542Remove_closet_leave_column SCALE: 1/4" = 1'-0"3 Ktichen Details SCALE: 1/4" = 1'-0"4 Fireplace Elevation Removal of entry closet Wrap existing column (no structural change) Beam exposed SHEET TITLE CONSULTANTS PROJECT NO: MODEL FILE: DRAWN BY: COPYRIGHT: SHEET 9 OF 58 A104 Jeffrey H. Woodruff Goldstein_09092020.pln Project No. 007 © 2020 /U s e r s / j e f f r e y w / D o c u m e n t s / C l o u d H i l l D e s i g n / A s p e n R e m o d e l / G o l d s t e i n _ 0 9 0 9 2 0 2 0 . p l n Parcel ID 273718109014 Account R004953 Jeffrey H. Woodruff Cloud Hill Design, LLC Snowmass, CO 81654 RDS Information / Demo Goldstein Residence Cloud Hill Design, LLC 1020 E Hopkins Unit #7 Aspen CO 81611 United States Brian Rossiter, P.E. Evolve Structural Carbondale, CO 81623 Jason Segal, Contractor Segal Development Carbondale, CO 81623 SCALE: 1' = 1'-0"1 Living_room_add_window_exterior SCALE: 1' = 1'-0"2 Living_room_add_window SCALE: 1' = 1'-0"3 20200813132414_001 copy Addition of Living Room Window. Match existing Riverview Condominium Fenestration, See Plan, See HOA approval letter Addition of Living Room Window. Match existing Riverview Condominium Fenestration, See Plan, See HOA approval letter See Structural Engineer Letter (add 3 LVL header) SHEET TITLE CONSULTANTS PROJECT NO: MODEL FILE: DRAWN BY: COPYRIGHT: SHEET 10 OF 58 A105 Jeffrey H. Woodruff Goldstein_09092020.pln Project No. 007 © 2020 /U s e r s / j e f f r e y w / D o c u m e n t s / C l o u d H i l l D e s i g n / A s p e n R e m o d e l / G o l d s t e i n _ 0 9 0 9 2 0 2 0 . p l n Parcel ID 273718109014 Account R004953 Jeffrey H. Woodruff Cloud Hill Design, LLC Snowmass, CO 81654 RDS Information Goldstein Residence Cloud Hill Design, LLC 1020 E Hopkins Unit #7 Aspen CO 81611 United States Brian Rossiter, P.E. Evolve Structural Carbondale, CO 81623 Jason Segal, Contractor Segal Development Carbondale, CO 81623 • Based on NFRC testing/simulation conditions using Windows v7.4.6.0 and NFRC validated spectral data. 0°F outside temperature, 70°F inside temperature and 15 mph wind. 1) Visible Transmittance (VLT) measures how much light comes through the glass. The higher the value, from 0 to 1, the more daylight the glass lets in. Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. 2) Shading Coefcient denes the amount of heat gain through the glass compared to a single light of clear 1/8" (3 mm) glass. 3) Solar Heat Gain Coefcient (SHGC) denes the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the glass. 4) Relative Heat Gain is the amount of heat gain through a glazing incorporating U-Factor and Solar Heat Gain Coef cient. 5) Transmission Ultra-Violet Energy (TUV). The transmission of short-wave energy in the 300-380 nanometer portion of the solar spectrum. The energy can cause fabric fading. 6) Transmission Damage Function (TDW). The transmission of UV and visible light energy in the 300-600 nanometer portion of the solar spectrum. The value includes both the UV and visible light energy that can cause fabric fading. This rating has also been referred to as the Krochmann Damage Function. This rating better predicts fading potential than UV transmission alone. The lower the Damage Function rating, the less transmission of short-wave energy through the glass that can potentially cause fabric fading. Fabric type is also a key component of fading potential. 7) Percent relative humidity before condensation occurs at the center of glass, taken using center of glass temperature. 8) Inside glass surface temperatures are taken at the center of glass. • This data is accurate as of June 2019. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. Contact your Andersen supplier for current performance information or upgrade options. • Contact your Andersen supplier or visit andersenwindows.com/nfrc for center of glass performance data on windows with patterned glass, tempered glass and products ordered with capillary breather tubes. Center of Glass Performance Data — 100 Series Windows and Patio Doors For current performance information, please visit andersenwindows.com. Andersen® Product and Glass Type VLT1 SC 2 SHGC 3 RHG 4 Fading %RH @ center3 IGST 8Tuv5Tdw6 High-Performance Low-E Glass Casement, Awning, Single-Hung & Gliding Windows 72%0.48 0.41 98.2 16%33%61%55.7 Picture, Transom & Specialty Windows 72%0.47 0.41 97.5 16%33%60%55.3 Gliding Patio Doors 72%0.47 0.41 97.5 16%33%60%55.3 Patio Door Sidelights & Transoms 72%0.47 0.41 97.5 16%33%60%55.3 High-Performance Low-E SmartSun™ Glass Casement, Awning, Single-Hung & Gliding Windows 65%0.31 0.27 65.6 5%21%62%56.1 Picture, Transom & Specialty Windows 65%0.31 0.27 64.9 5%21%61%55.7 Gliding Patio Doors 65%0.31 0.27 64.9 5%21%61%55.7 Patio Door Sidelights & Transoms 65%0.31 0.27 64.9 5%21%61%55.7 Dual-Pane Glass Casement, Awning, Single-Hung & Gliding Windows 82%0.89 0.78 186 58%61%39%43.7 Picture, Transom & Specialty Windows 82%0.89 0.78 186 58%61%39%43.6 Gliding Patio Doors 82%0.89 0.78 186 58%61%39%43.6 Patio Door Sidelights & Transoms 82%0.89 0.78 186 58%61%39%43.6 PRODUCT PERFORMANCE Page 3 of 32019-20 100 Series Product Guide2019-20 100 Series Product Guide Page 1 of 1 HALLMARK CERTIFICATION The Window and Door Manufacturers Association (WDMA)-sponsored Hallmark Certication Program provides manufacturers with certication to the AAMA/WDMA/CSA 101/I.S.2/A440-11 Standard and is designed to provide builders, architects, speciers and consumers with an easily recognizable means of identifying products that have been manufactured and tested in accordance with NAFS (AAMA/WDMA/CSA 101/I.S.2/A440) industry standards and other applicable performance standards. Conformance is determined by periodic in-plant inspections by a third-party administrator. Inspections include auditing licensee quality control procedures and processes and a review to conrm products are manufactured in accordance with the appropriate performance standards. Periodic testing of representative product constructions and components by an independent testing laboratory is also required. When all of the program requirements are met, the licensee is authorized to use the WDMA Hallmark registered logo on their certication label as a means of identifying products and their performance ratings. Products successfully obtaining Hallmark Certication will be labeled with a three-part code, which includes performance class, performance grade and size tested. In addition to this mandatory requirement, you are allowed to list the design pressure on a separate line. (1) – Performance Class (2) – Performance Grade (3) – Size Tested (4) – Design Pressure In the example above, the performance class is LC, the performance grade (PG) is 40 pounds per square foot (psf) and the size tested is 71.5" x 71.5". What this means to the specier is, based on the performance grade chart, the laboratory-tested air inltration was less than 0.3 cfm/ft2 (test pressure is always 1.57 psf and the allowable airow is 0.3 cfm/ft 2), the product tested successfully resisted a laboratory water penetration test at a test pressure of 6.0 psf, the product tested successfully withstood a laboratory positive test pressure of 60 psf and a laboratory negative test pressure of 67 psf and the product tested passed the laboratory requirements for operational force and forced-entry resistance. Based on this test, all products of the same design that are smaller than the tested size can be labeled with this product performance rating. IMPORTANT Building codes prescribe design pressure based on a variety of criteria (i.e. windspeed zone, building height, building type, jobsite exposure, etc.). Design pressures derived from Performance Grade (PG) test requirements should be used to determine compliance to building code required design pressures. Structural test pressures, which are tested at 1.5 times the design pressure, should not be used for determining design pressure code compliance. In the example above, a PG 40 performance grade rating, which passes a 40 psf design pressure, should be used for determining code compliance, not the structural test pressure of 60 psf. If you need further details about how Andersen® products perform to this standard, contact your Andersen supplier. If you need further information about the AAMA/WDMA/CSA 101/I.S.2/A440-11 standard or the Hallmark Certication Program, please contact: WDMA, 330 N. Wabash Avenue Suite 2000, Chicago, IL 60611 Phone: 312-673-4828 Web: wdma.com Where designated, Andersen products are tested, certied and labeled to the requirements of the Hallmark Certication Program. Actual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use. PERFORMANCE STANDARDS The Window and Door Manufacturers Association (WDMA), the American Architectural Manufacturers Association (AAMA) and the Canadian Standards Association (CSA) jointly release the North American Fenestration Standard/Specication for Windows, Doors and Skylights (NAFS-11) where "-11" refers to the most recent publication year of 2011. NAFS is also referred to as AAMA/WDMA/CSA 101/I.S.2/A440, which is how the International Code Council (ICC) lists this standard in the 2012 and 2015 International Residential Code (IRC) and International Building Code (IBC) as the means to indicate the window, door or skylights design pressure rating used to determine compliance to the jobsite design pressure requirements. A product only achieves a “Performance Grade” or “PG” rating when it complies with all of the NAFS performance requirements such as ease of operation, air inltration resistance, resistance to water penetration and resistance to forced entry, etc. A “Design Pressure Rating” or “DP” rating only depicts the design and structural load performance. Performance Classes The NAFS Standard/Specication denes requirements for four performance classes. Performance classes are designated R, LC, CW, and AW. This classication system provides for several levels of performance. Product selection is always based on the performance and building code requirements of the particular project. +DOOPDUN&HUWL¿HG www.wdma.com Andersen Corporation 100 SERIES CASEMENT WINDOW Manufacturer stipulates certication as indicated below. Class LC(1) – PG40(2) – Size Tested 71.5 x 71.5 in.(3) DP+40/-45(4) Class LC(1) – PG40(2) – Size Tested 71.5 x 71.5 in.(3) DP+40/-45(4) STANDARD RATING AAMA/WDMA/CSA 101/I.S.2/A440-11 AAMA/WDMA/CSA 101/I.S.2/A440-08 Performance Class/ Performance Grade Air Infiltration Test Pressure Maximum Allowable Air Infiltration/ Exfiltration Rate Water Penetration Resistance Test Pressure Design Pressure Structural Test Pressure R LC Pa psf L/s·m 2 cfm/ft2 Pa psf Pa psf Pa psf 15 - 75 1.57 1.5 0.30 140 2.92 720 15.04 1080 22.56 20 - 75 1.57 1.5 0.30 150 3.13 960 20.05 1440 30.08 25 25 75 1.57 1.5 0.30 180 3.76 1200 25.06 1800 37.59 30 30 75 1.57 1.5 0.30 220 4.59 1440 30.08 2160 45.11 35 35 75 1.57 1.5 0.30 260 5.43 1680 35.09 2520 52.63 40 40 75 1.57 1.5 0.30 290 6.06 1920 40.10 2880 60.15 45 45 75 1.57 1.5 0.30 330 6.89 2160 45.11 3240 67.67 50 50 75 1.57 1.5 0.30 360 7.52 2400 50.13 3600 75.19 55 55 75 1.57 1.5 0.30 400 8.35 2640 55.14 3960 82.71 60 60 75 1.57 1.5 0.30 440 9.19 2880 60.15 4320 90.23 65 65 75 1.57 1.5 0.30 470 9.82 3120 65.16 4680 97.74 70 70 75 1.57 1.5 0.30 510 10.65 3360 70.18 5040 105.26 75 75 75 1.57 1.5 0.30 540 11.28 3600 75.19 5400 112.78 80 80 75 1.57 1.5 0.30 580 12.11 3840 80.20 5760 120.30 85 85 75 1.57 1.5 0.30 580 12.11 4080 85.21 6120 127.82 90 90 75 1.57 1.5 0.30 580 12.11 4320 90.23 6480 135.34 95 95 75 1.57 1.5 0.30 580 12.11 4560 95.24 6840 142.86 100 100 75 1.57 1.5 0.30 580 12.11 4800 100.25 7200 150.38 Elements of Performance Grade (PG) Designations In order to qualify for a given performance grade (PG), test specimens need to pass all required performance tests for the following, in addition to all required auxiliary (durability) and applicable material/component tests (not shown here) for the applicable product type and desired performance class: (a) Operating force (if applicable): Maximum operating force varies by product type and performance class. (b) Air leakage resistance: Tested in accordance with ASTM E283 at a test pressure of 1.57 psf. Allowable air inltration for R, LC and CW class designations is 0.3 cubic feet per minute per square foot of frame (cfm/ft2). (c) Water penetration resistance: Tested in accordance with ASTM E547 with the specied test pressure applied per NAFS-11. Test consists of four cycles. Each cycle consists of ve minutes with pressure applied and one minute with the pressure released, during which the water spray is continuously applied. Water spray shall be uniformly applied at a constant rate of 5 U.S. gal/ft2 • hr. (d) Uniform load deection test: Tested in accordance with ASTM E330 for both positive and negative pressure (pressure dened by NAFS-11) with the load maintained for a period of 10 seconds. The test specimen shall be evaluated for de ection during each load for permanent damage after each load and for any effects on the normal operation of the specimen. Starting with the 2008 version of NAFS, design pressure (DP) will only represent the "uniform load deection test". (e) Uniform load structural test: Tested in accordance with ASTM E330 for both positive and negative pressure (pressure dened by NAFS-11) with the load maintained for a period of 10 seconds. After loads are removed, there shall be no permanent deformation in excess of 0.4% of its span and no damage to the unit, which would make it inoperable. (f) Forced-entry resistance (if applicable): Tested in accordance with ASTM F588 (windows), F476 (swinging doors) and F842 (sliding doors) at a performance level 10 rating. Performance Grades (PG) & Corresponding Test Pressures (psf) PRODUCT PERFORMANCE 2019-20 100 Series Product Guide Page 1 of 2 Performance Grade, Air Inltration and Sound Transmission Ratings — 100 Series Windows and Patio Doors STANDARD GLASS STC UPGRADE GLASS Andersen® Product AAMA/WDMA/CSA 101/I.S.2/A440 Performance Grade (PG) +/- Corresponding Design Pressure (DP) Sound Transmission Class (STC) Outdoor/Indoor Transmission Class (OITC) Sound Transmission Class (STC) Outdoor/Indoor Transmission Class (OITC) Air Infiltration CFM/FT2 Casement Windows Single & Twin (venting/stationary)Class LC-PG40 Size Tested 71.5" x 71.5"+40/-45 30 25 33 28 < 0.2 Single & Twin, PG Upgrade (venting/stationary)Class LC-PG50 Size Tested 71.5" x 71.5"+50/-50*30 25 33 28 < 0.2 Picture with Flanking Casements Class LC-PG40 Size Tested 143.5" x 71.5"+40/-45 ----< 0.2 Picture with Flanking Casements, PG Upgrade Class LC-PG50 Size Tested 143.5" x 65.5"+50/-50*----< 0.2 Awning Windows Single & Twin (venting/stationary)Class LC-PG40 Size Tested 47.5" x 95.5"+40/-45 30 25 33 28 < 0.2 Single & Twin, PG Upgrade (venting/stationary)Class LC-PG50 Size Tested 47.5" x 95.5"+50/-50*30 25 33 28 < 0.2 Picture over Awning Class LC-PG40 Size Tested 47.5" x 95.5"+40/-45 ----< 0.2 Picture over Awning, PG Upgrade Class LC-PG50 Size Tested 47.5" x 95.5"+50/-50*----< 0.2 Single-Hung Windows Arch Single-Hung Class LC-PG30 Size Tested 41.5" x 95.0"+30/-30 ----< 0.2 Arch Single-Hung, PG Upgrade Class LC-PG50 Size Tested 41.5" x 83.0"+50/-50*----< 0.2 Single-Hung Class LC-PG30 Size Tested 47.5" x 89.5"+30/-30 28 23 32 26 < 0.2 Single-Hung, PG Upgrade Class LC-PG50 Size Tested 47.5" x 77.5"+50/-50*28 23 32 26 < 0.2 Twin & Triple Single-Hung Class LC-PG30 Size Tested 143.5" x 71.5"+30/-30 ----< 0.2 Twin & Triple Single-Hung, PG Upgrade Class LC-PG50 Size Tested 143.5" x 65.5"+50/-50*----< 0.2 Transom over Single-Hung Class LC-PG30 Size Tested 47.5" x 95.5"+30/-30 ----< 0.2 Transom over Single-Hung, PG Upgrade Class LC-PG50 Size Tested 47.5" x 95.5"+50/-50*----< 0.2 Picture with Flanking Single-Hungs Class LC-PG30 Size Tested 143.5" x 71.5"+30/-30 ----< 0.2 Picture with Flanking Single-Hungs, PG Upgrade Class LC-PG50 Size Tested 143.5" x 59.5"+50/-50*----< 0.2 Gliding Windows Gliding - Active-Stationary or Stationary-Active Class LC-PG30 Size Tested 71.5" x 71.5"+30/-30 28 23 32 27 < 0.2 Gliding, PG Upgrade - Active-Stationary or Stationary-Active Class LC-PG50 Size Tested 71.5" x 59.5"+50/-50*28 23 32 27 < 0.2 Picture over Gliding - Active-Stationary or Stationary-Active Class LC-PG30 Size Tested 59.5" x 83.5"+30/-30 ----< 0.2 Gliding - Active-Stationary-Active Class LC-PG30 Size Tested 143.5" x 71.5"+30/-30**----< 0.2 Gliding, PG Upgrade - Active-Stationary-Active Class LC-PG50 Size Tested 101.5" x 59.5"+50/-50*----< 0.2 Picture over Gliding - Active-Stationary-Active Class LC-PG30 Size Tested 107.5" x 83.5"+30/-30**----< 0.2 Picture, Transom & Specialty Windows Picture, Transom & Specialty Windows Class LC-PG40 Size Tested 95.5" x 84.3"+40/-40 29 24 32 27 < 0.2 Picture, Transom & Specialty Windows, PG Upgrade Class LC-PG50 Size Tested 95.5" x 71.5"+50/-50*29 24 32 27 < 0.2 Gliding Patio Doors Class LC-PG30 Size Tested 95.3" x 95.5"+30/-30 28 23 29 26 < 0.2 Patio Door Transoms Class LC-PG30 Size Tested 95.3" x 23.3"+30/-30 29 24 31 26 < 0.2 Patio Door Sidelights Class LC-PG30 Size Tested 47.3" x 95.3"+30/-30 29 24 31 26 < 0.2 For current performance information, please visit andersenwindows.com. • "Performance Grade (PG)" ratings may vary from tested performance rating for larger or smaller units of a particular type. • "Sound Transmission Class (STC)" & "Outdoor/Indoor Transmission Class (OITC)" ratings are for individual units with 3mm glass based on independent tests and represent entire unit. • This data is accurate as of June 2019. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. • Where designated, Andersen products are certied and labeled to the requirements of the Hallmark Certication Program. Actual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use. • Contact your Andersen supplier for more information. *Available for select sizes, contact your Andersen supplier. **Windows with insert frame (no ange with exterior accessory kerf) are rated at PG20. PRODUCT PERFORMANCE 2019-20 100 Series Product Guide Page 2 of 2 • Casement windows • Awning windows • Single-hung windows • Gliding windows • Picture windows • Transom windows • Specialty Windows PRODUCT TYPES Whether you’re replacing, remodeling or building new, Andersen® 100 Series products offer many advantages over vinyl at a good value. They’re made of our innovative Fibrex® composite material that’s 2X stronger than vinyl, environmentally smart, energy efficient and offers superior strength and performance making them a better choice for your home. 100 SERIES Windows A BETTER CHOICE *Visit andersenwindows.com/warranty for details. **When 100 Series products were tested against five leading competitors’ painted vinyl window products. • Fibrex material construction provides long-lasting performance • Weatherstrip is designed to be an energy-efficient barrier against wind, water and dust • Virtually seamless corners offer a cleaner, more contemporary look • Premium matte finish never needs painting and won’t fade, flake, blister or peel* • 100 Series products have a 12X thicker finish than that of painted vinyl windows** resulting in superior scratch resistance Lock automatically engages when window is closed. Hardware color matches the window’s interior. Shown in white. Bold name denotes finish shown. Antique Brass | Black | Dark Bronze Sandtone | Satin Nickel | White Lock LockOptional Lift/Pull CASEMENT & AWNING 100 SERIES W indows GLASS OPTIONS FRAME OPTIONS • Low-E glass • Low-E glass with HeatLock® technology • Low-E Sun glass • Low-E SmartSun™ glass • Low-E SmartSun glass with HeatLock technology Tempered glass, sound reducing glass and patterned glass is available. Contact your Andersen supplier for availability. 1 3/8" flange setback, 1" flange setback with stucco key or replacement configurations with or without an accessory kerf available. **Hardware is sold separately, except standard hardware. †When properly configured and maintained with a professionally installed security system and/or self-monitoring system compatible with Honeywell® 5800 controls. Printing limitations prevent exact replication of colors and finishes. See your Andersen supplier for actual color and finish samples. “ENERGY STAR” is a registered trademark of the U.S. Environmental Protection Agency. “Andersen” and all other marks where denoted are trademarks of Andersen Corporation. ©2020 Andersen Corporation. All rights reserved. 02/20 SINGLEHUNG & GLIDING Antique Brass | Black | Dark Bronze Sandtone | Satin Nickel | White Folding handle avoids interference with window treatments. Standard FoldingStandardOptional Slim Line Metal Hardware PRODUCT OPTIONS Black*White Sandtone*Dark Bronze* EXTERIOR COLORS INTERIOR COLORS *Products with Sandtone, dark bronze, and black interiors have matching exteriors. BlackWhiteTerratoneSandtoneDark Bronze For more information, visit andersenwindows.com/100series • Wireless Open/Closed Sensor Indicates if windows are open or closed† for peace of mind and feature a sleek, compact design for a clean appearance. • Grilles Variety of grille options available including Finelight™ grilles-between-the-glass for convenient cleaning and full divided light grilles for an authentic look. • Insect Screens Optional TruScene® insect screens for windows provide 50% more clarity than our conventional insect screens, letting in more air and sunlight. ACCESSORIES HARDWARE OPTIONS** Page 40 of 75 Data is current as of January 2017 and is subject to change. See page 1 for more information. No r t h e r n N. C e n t r a l S. C e n t r a l So u t h e r n Zo n e 1 Zo n e 2 Zo n e 3 3.0mm Annealed or 3.1mm Tempered Glass - w/ No Grilles and Grilles Less Than 1" No Grilles AND-N-82-03683-00001 0.28 1.59 0.33 0.56 24 < 0.2 61 N NC --Z1 -- Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03683-00002 0.28 1.59 0.29 0.50 22 < 0.2 61 -NC --Z1 -- Finelight™ (grilles-between-the-glass)AND-N-82-03690-00001 0.28 1.59 0.29 0.50 22 < 0.2 61 -NC --Z1 -- Finelight™ w/ Exterior Applied (FLE)AND-N-82-03690-00001 0.28 1.59 0.29 0.50 22 < 0.2 61 -NC --Z1 -- Full Divided Lite (FDL)AND-N-82-04609-00001 0.29 1.65 0.29 0.50 20 < 0.2 61 -NC ----- No Grilles AND-N-82-03685-00001 0.27 1.53 0.22 0.50 19 < 0.2 61 N NC SC S Z1 -- Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03685-00002 0.27 1.53 0.20 0.45 18 < 0.2 61 N NC SC S Z1 -- Finelight™ (grilles-between-the-glass)AND-N-82-03692-00001 0.27 1.53 0.20 0.45 18 < 0.2 61 N NC SC S Z1 -- Finelight™ w/ Exterior Applied (FLE)AND-N-82-03692-00001 0.27 1.53 0.20 0.45 18 < 0.2 61 N NC SC S Z1 -- Full Divided Lite (FDL)AND-N-82-04611-00001 0.28 1.59 0.20 0.45 17 < 0.2 61 -NC SC S Z1 -- No Grilles AND-N-82-03682-00001 0.29 1.65 0.54 0.61 35 < 0.2 60 N ---Z1 Z2 Z3 Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03682-00002 0.29 1.65 0.48 0.55 31 < 0.2 60 N ---Z1 Z2 - Finelight™ (grilles-between-the-glass)AND-N-82-03689-00001 0.29 1.65 0.48 0.55 31 < 0.2 60 N ---Z1 Z2 - Finelight™ w/ Exterior Applied (FLE)AND-N-82-03689-00001 0.29 1.65 0.48 0.55 31 < 0.2 60 N ---Z1 Z2 - Full Divided Lite (FDL)AND-N-82-04608-00001 0.30 1.70 0.48 0.55 30 < 0.2 60 N ---Z1 Z2 - No Grilles AND-N-82-03687-00001 0.24 1.36 0.32 0.55 29 < 0.2 48 N NC --Z1 Z2 - Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03687-00002 0.24 1.36 0.29 0.49 27 < 0.2 48 N NC --Z1 Z2 - Finelight™ (grilles-between-the-glass)AND-N-82-03694-00001 0.24 1.36 0.29 0.49 27 < 0.2 48 N NC --Z1 Z2 - Finelight™ w/ Exterior Applied (FLE)AND-N-82-03694-00001 0.24 1.36 0.29 0.49 27 < 0.2 48 N NC --Z1 Z2 - Full Divided Lite (FDL)AND-N-82-04613-00001 0.25 1.42 0.29 0.49 25 < 0.2 48 N NC --Z1 -- No Grilles AND-N-82-03688-00001 0.23 1.31 0.21 0.49 23 < 0.2 49 N NC SC S Z1 Z2 - Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03688-00002 0.23 1.31 0.19 0.44 22 < 0.2 49 N NC SC S Z1 Z2 - Finelight™ (grilles-between-the-glass)AND-N-82-03695-00001 0.23 1.31 0.19 0.44 22 < 0.2 49 N NC SC S Z1 Z2 - Finelight™ w/ Exterior Applied (FLE)AND-N-82-03695-00001 0.23 1.31 0.19 0.44 22 < 0.2 49 N NC SC S Z1 Z2 - Full Divided Lite (FDL)AND-N-82-04614-00001 0.25 1.42 0.19 0.44 20 < 0.2 49 N NC SC S Z1 -- 3.0mm Annealed or 3.1mm Tempered Glass - w/ Grilles 1" or Greater Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03683-00003 0.28 1.59 0.26 0.44 20 < 0.2 61 -NC --Z1 -- Finelight™ (grilles-between-the-glass)AND-N-82-03697-00001 0.29 1.65 0.29 0.50 20 < 0.2 61 -NC ----- Finelight™ w/ Exterior Applied (FLE)n/a n/a n/a n/a n/a n/a n/a n/a ------- Full Divided Lite (FDL)n/a n/a n/a n/a n/a n/a n/a n/a ------- Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03685-00003 0.27 1.53 0.18 0.40 17 < 0.2 61 N NC SC S Z1 -- Finelight™ (grilles-between-the-glass)AND-N-82-03699-00001 0.29 1.65 0.20 0.45 15 < 0.2 61 -NC SC S --- Finelight™ w/ Exterior Applied (FLE)n/a n/a n/a n/a n/a n/a n/a n/a ------- Full Divided Lite (FDL)n/a n/a n/a n/a n/a n/a n/a n/a ------- Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03682-00003 0.29 1.65 0.43 0.49 29 < 0.2 60 N ---Z1 Z2 - Finelight™ (grilles-between-the-glass)AND-N-82-03696-00001 0.30 1.70 0.48 0.55 30 < 0.2 60 N ---Z1 Z2 - Finelight™ w/ Exterior Applied (FLE)n/a n/a n/a n/a n/a n/a n/a n/a ------- Full Divided Lite (FDL)n/a n/a n/a n/a n/a n/a n/a n/a ------- Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03687-00003 0.24 1.36 0.26 0.43 25 < 0.2 48 N NC --Z1 Z2 - Finelight™ (grilles-between-the-glass)AND-N-82-03701-00001 0.25 1.42 0.29 0.49 25 < 0.2 48 N NC --Z1 -- Finelight™ w/ Exterior Applied (FLE)n/a n/a n/a n/a n/a n/a n/a n/a ------- Full Divided Lite (FDL)n/a n/a n/a n/a n/a n/a n/a n/a ------- Simulated Divided Lite (SDL) or Installed Interior Removable AND-N-82-03688-00003 0.23 1.31 0.17 0.39 21 < 0.2 49 N NC SC S Z1 Z2 - Finelight™ (grilles-between-the-glass)AND-N-82-03702-00001 0.24 1.36 0.19 0.44 21 < 0.2 49 N NC SC S Z1 Z2 - Finelight™ w/ Exterior Applied (FLE)n/a n/a n/a n/a n/a n/a n/a n/a ------- Full Divided Lite (FDL)n/a n/a n/a n/a n/a n/a n/a n/a ------- Lo w - E Lo w - E Sm a r t S u n ™ Lo w - E Sm a r t S u n ™ w/ H e a t l o c k ™ Lo w - E Low - E Sm a r t S u n ™ Lo w - E Pa s s i v e S u n ® Lo w - E Pa s s i v e S u n ® Lo w - E w/ H e a t l o c k ™ Lo w - E w/ H e a t L o c k ™ Lo w - E Sm a r t S u n ™ w/ H e a t l o c k ™ Andersen® Product Line & Product Type Andersen Glass Type Canada ENERGY STAR SH G C ² VT ³ Ca n a d a E R Ai r I n f i l t r a t i o n Co n d e n s a t i o n Re s i s t a n t a n c e 100 Series Picture U.S. ENERGY STAR Grille Type NFRC Certified Products Directory Number U- F a c t o r ¹ U- F a c t o r ¹ Me t r i c Meets 2015 International Energy Conservation Code