HomeMy WebLinkAbout90.Architectural Plans.2021.01.11CIVIL ENGINEER:
-
CONTACT:
-
-
COL.
C.O.
CEILING HEIGHT A.F.F.+13'-11"
PROJECT ADDRESS:
PARCEL ID:
FIRE SPRINKLER SYSTEM INSTALLED:
APPLICABLE CODES:
·2015 IRC (International Residential Code) Chapters 1-10
·2015 IRC appendixes:
·Manufactured homes, F: Radon, J: Existing Buildings & Structures, H:Patio Covers, K: Sound Transmission.
·2015 IPC (International Plumbing Code)
·2015 IMC (International Mechanical Code)
·2015 IFGC (International Fuel Gas Code)
·2015 IECC (International Energy Conservation Code) - Prescriptive Path
·2015 IFC (International Fire Code)
·2015 NEC (National Electrical Code)
1028 E. Hopkins Ave. #27, Aspen CO 81611
273718109026
NO
R-15
XX sq ft EXISTING, XX sq ft PROPOSED (NO CHANGE)
Residential
Front - 25', Side and Rear - 10'
ZONING:
F.A.R.
PERMITTED USE:
SETBACKS:
Tread
Terrazzo
Thick
Tempered
TEL.
T.C.
T.B.
T.
THK.
T.M.E.
T.O.C.
T.&G.
TER.
TEMP.
To Match Existing
Top of Concrete
Towel Bar
Top of Curb
Telephone
Tongue & Groove
Typical
Varies
UnfinishedUNF.
V.C.T.
VAR.
U.O.N.
UNEXC.
U.B.C.
T.O. PLY
T.O.W.
TYP.
Veneer
Vertical
Vestibule
Volume
Wood
West
With
V.I.F.
W.C.
WD.
W.H.
W.
W/
V.G.D.F.
VOL.
VERT.
VEST.
VEN.
Wall Covering
Water Heater
Vertical Grain Douglas Fir
Verify in Field
Vinyl Composition Tile
Top of Plywood
Top of Wall
Uniform Building Code
Unexcavated
Unless Otherwise Noted
Top of PlateT.O.P.
Wainscot
Weight
W.P.
WW.
WR.
WT.
W.S.P.
W.P.M.
WSCT.
Welded Wire
Work Point or
Waterproofing
Waterproof Membrane
Wet Standpipe
Water Resistant
WithoutW/O
REQ.
RESIL.
REINF.
REG.
REV.
RWD.
REMOV.
R.O.
RM.
RET.
Rough Opening
Redwood
Required
Removable
Room
Resilient
Retaining
Reinforced
Register
Mounted
Mullion
Nominal
North
Number
New
Not to Scale
Miscellaneous
Not in Contract
S.C.D.
S.D.
S.
S.A.F.F
SEP.
SHT.
S.H.
SECT.
S.E.D.
SCHED.
Separation
Sprinkler Head
Sheet
See Civil Drawings
Soap Dispenser/Dish
See Electrical Drawings
Storm Drain,
Schedule
Section
Self-Adhesive Flexible Flashing
South
S.G.D.
S.L.D.
SHTG.
S.C.D.
SL.
SIM.
S.P.D.
SPEC.
S.M.D.
S.S.
SQ.
S.LT.D.
Stainless Steel
Square
See Lighting Drawings
See Garage Drawings
See Plumbing Drawings
See Civil Drawings
Sheathing
Sliding
Similar
Opposite
Opening
On Center
Overall
Plaster
Plywood
Perimeter
Plate
Plastic Laminate
Outside Diameter (Dim.)
Point
Paint
Quarry Tile
Partition
Painted
Paper Towel Receptacle
Per Square Inch
Pressure Treated
Post Tensioned
Paper Towel Dispenser
Panel
MUL.
MISC.
MTD.
NOM.
N.T.S.
N.I.C.
N.
(N)
Hardware
Hardwood
Hanger
Height
Horizontal
Handrail
Hour
Hot Water Heater
Hollow Metal
HGT.
HDW.
HDWD.
HGR.
H.W.H.
HORIZ.
HR.
H.R.
H.M.
Floor Drain
Fire Extinguisher
Cabinet
Flat Bar
Fixture
Floor
Srew
Finish
Flat Head Wood Screw
Flat Head Machine
OPP.
O.A.
O.C.
O.D.
PLAS.
PL.
Insulation
Interior
Inch
Kitchen
Joist
Joint
Janitor
Junction Box
Intermediate
P.S.I.
PNT.
PT.
P.T.
P.T.R.
P.T.D.
PTN.
Q.T.
PTD.
Laminate
Lavatory
Pound
Linear
Light
Maintain
Material
Maximum
Machine
PNL.
INTER.
IN.
INSUL.
INT.
KIT.
JST.
JB
JT.
JAN.
Fluorescent
Face of Finish
Face of Plywood
Face of Stud
Footing
Furring
Future
Frame
Foot or Feet
Fireproof
Face of Concrete
LB.
LIN.
LT.
LAM.
LAV.
MAINT.
MAT.
MAX.
MACH.
General
Gauge
Gas Outlet
Galvanized
Ground
Grade
Glass
Interrupt
Ground Fault
Galvanized Sheet
Garbage Disposal
Flashing Inside DiameterI.D.
ABBREVIATIONS
P.LAM.
PLYWD.
PERIM.
OPNG.
NO. or #
STOR.
STRL.
STD.
STL.
S.V.
SYS.
SYM.
S.W.
System
Steel
Structural
Sheet Vinyl
Shear Wall
Symmetrical
Storage
StandardReturn Air
Recessed
Radius
Riser
Reference
Reflected
Refrigerator
REC.
RAD.
R.A.
R.
REFR.
REFL.
REF.
Overlay
Mechanical
Membrane
Minimum
Metal
Machine Bolt
Medicine Cabinet
Medium Density
Manufacturer
M.D.O.
MEMB.
MECH.
M.B.
M.C.
MIN.
MTL.
MFR.
Gypsum
Handicapped
Hose Bibb
Hollow Core or
Header
Head
Hardboard
Metal
S.S.D. See Structural Drawing
Specification or Special
See Landscape Drawings
See Mechanical Drawings
Revision/Revised/Reversed
F.E.
F.B.
F.D.
FIXT.
FLR.
F.H.W.S.
FIN.
F.H.M.S.
CONSTR.
CONN.
COND.
CONC.
CTR.
C.W.
C.T.
CONTR.
CLOS.
CONT.
Center
Cold Water
Contractor
Closet
Ceramic Tile
Condition
Connection
Construction
Continuous
Concrete
F.O. Ply
F.O.S.
FLUOR.
F.O.C.
F.O.F.
FURR.
FUT.
FTG.
FR.
FT.
F.P.R.F.
GALV.
G.D.
GEN.
G.
GA.
GND.
G.S.M.
GR.
GL.
G.F.I.
DIA.
DIM.
DBL.
DET.
D.F.
DWG.
DWR.
D.W.
DN.
DR.
DISP.
E.J.
EA.
(E)
E.I.F.S.
E.O.S.
ENCL.
E.P.B.
ELEC.
EMER.
EL.
Dishwasher
Edge of Slab
Electrical Panel Board
Enclosure
Exterior Insulation &
Elevation
Electrical
Emergency
Existing
Finish System
Expansion Joint
Each
Drawing
Drawer
Drinking Fountain
Dispenser
Down
Door
Double
Diameter
Dimension
Detail
FLASH.
At@
&
<
A.C.
#
0
ACOUS.
ALUM.
ALT.
ADJ.
AGGR.
ADJAC.
BITUM.
BD.
ARCH.
ASPH.
APPROX.
BM.
B.O.
BOT
BLKG.
BLK.
C.B.
CEM.
CER.
B.P.
BTWN.
BLDG.
A.D.
Catch Basin
Cement
Ceramic
Beam
Bottom of
Building Paper
Between
Bottom
Building
Blocking
Bituminous
Board
Block
Diameter or Round
Air Conditioning or
Asphaltic Concrete
Aluminum
Approximate
Architectural
Asphalt
Alternate
Acoustical
Area Drain
Adjustable
Aggregate
Adjacent
Pound or Number
Angle
And
H.B.
H.C.
GYP.
HDR.
HDBD.
HD.
EXP.
EXT.
EXIST.
EQUIP.
F.A.U.
F.A.
Forced Air Unit
Fire Alarm
Equipment
Existing
Expansion
Exterior
CLKG.
C.M.U.
CLR.
CLG.
CNTR.
Column
Concrete Masonry
Caulking
Clean-Out
Counter
Unit
Clear
Ceiling
C.J. Control Joint EqualEQ.
PROJECT DIRECTORYVICINITY PLAN
CONTACT: Ryan Doremus
STRUCTURAL ENGINEER:
LANDSCAPE DESIGN:
OWNER/CLIENT:
ARCHITECT:
Aspen, CO 81611
Thunderbowl Architects
300 Spring St. Suite 201
Email: ryan@thunderbowlarchitects.com
MJJ 2020 LLC
SHEET NUMBER
INTERIOR ELEVATION NUMBERS
SYMBOLS
3
A6.1
1
A4.3
DOOR SYMBOL14
1A
A
3
A6.1
DETAIL NUMBER
SHEET NUMBER
WINDOW SYMBOL
PARTITION TYPE
SHEET NUMBER
BUILDING SECTION NUMBER
SHEET NUMBER
ENLARGED DETAIL NUMBER
HOSE BIBB
REVISION
COLOR
FINISH MATERIAL
HB
JB
XX
X
1
(N)/(E) CONSTRUCTION
JUNCTION BOX
Aspen, Colorado
1028 E. HOPKINS AVE. #27
GENERAL NOTES
PROJECT STATISTICS
TYPE:
OCCUPANCY:
OVERALL PROJECT HEIGHT AND AREA:
PROJECT SUMMARY:
Type V - Non-rated
Type R-3
Maximum Height N/A - Area N/A
INTERIOR UPDATES TO KITCHEN CABINETS AND ROOM
CLOSETS; UPGRADING WINDOWS, SLIDING DOORS AND
PLUMBING FIXTURES TO CURRENT CODES AND EFFICIENCY
REQUIREMENTS. NEW FINISHES TO FLOORS AND WALLS.
-
-
CONTACT:
-
CONTRACTOR
A5.2
1
2
3
4
FOR ALL DRAWINGS
EXCEPT DETAILS
DIMENSIONING KEY
TICK LEADER DENOTES
DIMENSION TO FRAMING
DOT LEADER DENOTES
DIMENSION TO GRIDLINE/<
2'-2"3'-6"
ARROW LEADER DENOTES
DIMENSION TO FINISH
3'-5"
PERMIT SET
January 11, 2021
SITE
1028 E. Hopkins Ave. Ave 27
ASPEN, COLORADO
The work included under this contract consists of all labor, materials, transportation, tools and equipment necessary for the
construction of the project leaving all work ready for use.
The construction documents are the property of Thunderbowl Architects Inc and its Consultants and are to be used as
instruments of service for construction of this project only. Use for any other purpose, without authorization, is not
allowed.
The plans indicate the general extent of new construction necessary for the work, but are not intended to be all-inclusive.
All demolition and all new work necessary to allow for a finished job in accordance with the intention of the drawing is
included regardless of whether shown on the drawings or mentioned in the notes.
Any errors, omissions or conflicts found in the various parts of the construction documents shall be brought to the attention
of the Architect and the Owner for clarification before proceeding with the work.
The General Contractor shall maintain a current and complete set of the construction documents on the job site during all
phases of construction for use of all the trades and shall provide all the subcontractors with current and complete
construction documents as required including specifications and architectural supplementary instructions.
The General Contractor shall verify and assume responsibility for all dimensions and site conditions. The General
Contractor shall inspect the existing premises and take note of existing conditions prior to submitting prices. No claim shall
be allowed for difficulties encountered which could have reasonably been inferred from such an examination.
Written dimensions take precedence. Do not scale drawings.
See SYMBOLS area of this sheet for dimension standards.
All dimensions noted "verify" and "V.I.F." are to be checked by Contractor prior to construction. Immediately report any
variances to the Architect for resolution, then coordinate resolution w/ all work of all trades.
Coordinate all work with existing conditions, including but not limited to: irrigation pipes, electrical conduit, water lines, gas
lines, drainage lines, etc. Notify Architect immediately of any conflicts.
Provide adequate temporary support as necessary to assure the structural value or integrity of the building.
Protect all existing building and site conditions to remain, including walls, cabinets, finishes, trees and shrubs, paving, etc.
Details shown are typical. Similar details apply in similar conditions.
Verify all architectural details with structural, civil, landscape and design/build drawings before ordering or installation of
any work.
All changes in floor materials occur at centerline of door or framed opening unless otherwise indicated on the drawings.
Install all fixtures, equipment and materials per manufacturer's recommendations.
Verify clearances for flues, vents, chases, soffits, fixtures, etc. before any construction, ordering of, or installation of any
items of work.
Sealant, caulking and flashing, etc. locations shown on drawings are not intended to be inclusive. Follow manufacturer's
installation recommendations and standard industry and building practices.
The General Contractor shall remove all rubbish and waste materials of all subcontractors and trades on a regular basis,
and shall exercise a strict control over job cleaning to prevent any direct debris or dust from affecting, in any way, finished
areas in or outside job site.
Contractor shall leave premises and all affected areas clean and orderly, ready for occupancy. This includes cleaning of all
glass (inside and outside) and frames, both new and existing.
Any survey monuments within the area of construction shall be preserved or reset by a registered civil engineer or a
licensed land surveyor.
Verify all finish materials with the Architect and the Owner prior to installation. On site mock-ups of building assemblies,
finish assemblies, paint and/or stain samples, etc. may be required for approval.
Contractor to coordinate utilities shown on architectural drawings with electrical, plumbing, mechanical, and any other
consultant drawings. Contractor to coordinate all the trades.
Structural observation shall be required by the Engineer for structural conformance to the approved plans.
It is the General Contractors responsibility to obtain inspections and special inspections as necessary.
All construction to provide a waterproof, weather tight building. Contractor should flash and caulk as necessary to achieve
this requirement.
S. South
Albright & Associates
402 Park Ave., Unit E
Basalt, CO 81621
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
SHEET INDEX
NOT INCLUDED IN THIS SET
INCLUDED IN THIS SET
DATES ISSUEDSHEETTITLE
DELETED FROM SET
MECHANICAL DESIGN:
-
-
CONTACT:
-Tel: (XXX) XXX-XXXX
Email:
Tel: (XXX) XXX-XXXX
Email:
Tel: (XXX) XXX-XXXX
Email:
Tel: (970) 927-4363
Email: jack@albright-associates.com
Tel: (970) 274-1421
RD
S
S
E
T
DE
C
.
3
1
,
2
0
2
0
G-001 COVER
Tel: (970) 274-1421
CONTACT: Ryan Doremus (Thunderbowl Architects)
Aspen, CO 81611
300 Spring St. Suite 201
Email: ryan@thunderbowlarchitects.com
Garret Construction, Inc.
CONTACT: Todd Cerrone
3892 Crystal Bridge Dr.
Carbondale, CO 81623
Tel: (970) 948-3695
Email: todd@garretconstruction.com
todd.cerrone@gmail.com
Z-001 UNIT FLOOR AREA + CALCULATIONS
A-101 UNIT EXISTING AND PROPOSED FLOOR PLANS
G-001 UNIT FIRE AREA + CALCULATIONS
A-102 UNIT EXISTING AND PROPOSED RCP
A-601 WINDOW AND DOOR SCHEDULE
CONTACT: Jack Albright
PE
R
M
I
T
S
E
T
Ja
n
u
a
r
y
1
1
,
2
0
2
1
PROJECT
SCALE
NTS
20020.00
G-000
COVER SHEET
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
8
1
6
1
1
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
0
9
0
2
6
10
2
8
E
.
H
O
P
K
I
N
S
A
V
E
.
#
2
7
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
12/31/2020 RDS SET
1/11/2021 PERMIT SET
BEDROOM 2
108
BEDROOM 1
107
MASTER BEDROOM
104
DINING
102
KITCHEN
101
LIVING
103
ADJ. BUILDING HALLWAY
ADJ. BUILDING STAIR
NO
WORK
NO
WORK
HALL
109
CLOSETCLOSET
QUEEN
KING
BU
I
L
T
-
I
N
S
BUILT-INS
(E) 2- SIDED
WOOD F.P.;
NO CHANGE
WH
MASTER
BATH
105
BATH
106
BUILT-INS
TWIN
QUEEN
2'
-
1
1
1
/
4
"
5
1
/
8
"
2'
-
9
"
15'-11"3'-5 3/4"2'-11"13'-8 1/2"
2'
-
7
1
/
8
"
12
'
-
6
"
13'-4"
8'
-
8
5
/
8
"
1'
-
6
7
/
8
"
5'
-
0
"
9'
-
8
3
/
4
"
7
1
/
4
"
4'
-
1
0
3
/
4
"
6'
-
9
1
/
4
"
27
'
-
0
"
12
'
-
1
0
5
/
8
"
6'
-
0
1
/
2
"
,
V
.
I
.
F
.
4'
-
9
5
/
8
"
4'
-
3
1
/
3
2
"
5'
-
1
1
1
/
2
"
,
V
.
I
.
F
.
14
'
-
5
1
/
8
"
,
V
.
I
.
F
.
4'
-
2
5
/
8
"
11
'
-
3
1
/
4
"
,
V
.
I
.
F
.
8'
-
4
1
/
2
"
,
V
.
I
.
F
.
5'
-
1
1
/
4
"
2'
-
8
1
/
4
"
11'-6 5/8"5"
2'-11 3/4"10'-6 1/8"
17'-1"
3'-7 1/8"1'-7 1/32"
1'-3 5/16"
22'-5 1/4"
4 31/32"
1'-7"4'-0 5/32"3'-0"10'-6 15/16"
11
'
-
4
3
/
4
"
2'
-
1
1
"
3'
-
0
1
9
/
3
2
"
2'
-
6
1
1
/
1
6
"
5'
-
1
0
2
1
/
3
2
"
5'-3 7/32"4'-10 25/32"
11
'
-
3
"
2'
-
8
1
/
4
"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
V.
I
.
F
.
4'-11 3/32"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
4'-11 3/32"
2'-11 1/2"3'-6 1/4"
7 3/4"
2'-0"2'-0"2'-6 1/2"
9
1
/
2
"
2'
-
1
1
/
4
"
2'
-
1
0
1
/
4
"
2'
-
6
"
8'
-
8
3
/
8
"
,
V
.
I
.
F
.
V.
I
.
F
.
2'
-
9
1
/
2
"
10
'
-
9
"
3'-5 3/8"
11 5/32"
2'-6"7'-3 1/2", V.I.F.15'-8 1/4"
3'-0"
2'-9 1/2"
2'
-
0
3
/
8
"
2'
-
0
"
3'-8 1/4"3'-4"
1
1
/
2
"
O
F
F
G
R
I
D
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
UNIT FLOOR
AREA
1374.66 SQ. FT.
2'
-
1
1
1
/
4
"
5
1
/
8
"
2'
-
9
"
15'-11"3'-5 3/4"2'-11"13'-8 1/2"
2'
-
7
1
/
8
"
12
'
-
6
"
13'-4"
8'
-
8
5
/
8
"
1'
-
6
7
/
8
"
5'
-
0
"
9'
-
8
3
/
4
"
7
1
/
4
"
4'
-
1
0
3
/
4
"
6'
-
9
1
/
4
"
27
'
-
0
"
12
'
-
1
0
5
/
8
"
6'
-
0
1
/
2
"
,
V
.
I
.
F
.
4'
-
9
5
/
8
"
4'
-
3
1
/
3
2
"
5'
-
1
1
1
/
2
"
,
V
.
I
.
F
.
14
'
-
5
1
/
8
"
,
V
.
I
.
F
.
4'
-
2
5
/
8
"
11
'
-
3
1
/
4
"
,
V
.
I
.
F
.
8'
-
4
1
/
2
"
,
V
.
I
.
F
.
5'
-
1
1
/
4
"
2'
-
8
1
/
4
"
11'-6 5/8"5"
2'-11 3/4"10'-6 1/8"
17'-1"
3'-7 1/8"1'-7 1/32"
1'-3 5/16"
22'-5 1/4"
4 31/32"
1'-7"4'-0 5/32"3'-0"10'-6 15/16"
11
'
-
4
3
/
4
"
2'
-
1
1
"
3'
-
0
1
9
/
3
2
"
2'
-
6
1
1
/
1
6
"
5'
-
1
0
2
1
/
3
2
"
5'-3 7/32"4'-10 25/32"
11
'
-
3
"
2'
-
8
1
/
4
"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
V.
I
.
F
.
4'-11 3/32"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
4'-11 3/32"
2'-11 1/2"3'-6 1/4"
7 3/4"
2'-0"2'-0"2'-6 1/2"
9
1
/
2
"
2'
-
1
1
/
4
"
2'
-
1
0
1
/
4
"
2'
-
6
"
8'
-
8
3
/
8
"
,
V
.
I
.
F
.
V.
I
.
F
.
2'
-
9
1
/
2
"
10
'
-
9
"
3'-5 3/8"
11 5/32"
2'-6"7'-3 1/2", V.I.F.15'-8 1/4"
3'-0"
2'-9 1/2"
2'
-
0
3
/
8
"
2'
-
0
"
3'-8 1/4"3'-4"
1
1
/
2
"
O
F
F
G
R
I
D
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
NO
WORK
NO
WORK
BEDROOM 2
108
BEDROOM 1
107
MASTER BEDROOM
104
DINING
102
KITCHEN
101
LIVING
103
CLOSET
ADJ. BUILDING HALLWAY
ADJ. BUILDING STAIR
HALL
109
MASTER
BATH
105
BATH
106
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSETCLOSET
WH
(E) 2- SIDED
WOOD F.P.;
NO CHANGE
3'
-
1
0
1
/
2
"
4'
-
8
1
/
4
"
4'-3"4'-6 1/4"4'-10"
2'
-
6
3
/
4
"
UNIT FLOOR
AREA
1374.66 SQ. FT.
TOTAL SQUARE FOOTAGE OF
FIRE AREA = 1374.66 SQ. FT.
N
0 2 4 8
Scale: 1/4" = 1'-0"
PROPOSED UNIT #27 FLOOR PLAN - NO CHANGE
1/4" = 1'-0"
1
G-001
PROJECT
SCALE
1/4" = 1'-0"
20020.00
G-001
EXISTING AND
PROPOSED FIRE
AREA
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
8
1
6
1
1
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
0
9
0
2
6
10
2
8
E
.
H
O
P
K
I
N
S
A
V
E
.
#
2
7
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
12/31/2020 RDS SET
1/11/2021 PERMIT SET
EXISTING UNIT #27 FLOOR PLAN
1/4" = 1'-0"
1
G-001
AREA PLAN LEGEND
PROPOSED FIRE AREA
BEDROOM 2
108
BEDROOM 1
107
MASTER BEDROOM
104
DINING
102
KITCHEN
101
LIVING
103
ADJ. BUILDING HALLWAY
ADJ. BUILDING STAIR
NO
WORK
NO
WORK
HALL
109
CLOSETCLOSET
QUEEN
KING
BU
I
L
T
-
I
N
S
BUILT-INS
(E) 2- SIDED
WOOD F.P.;
NO CHANGE
WH
MASTER
BATH
105
BATH
106
BUILT-INS
TWIN
QUEEN
2'
-
1
1
1
/
4
"
5
1
/
8
"
2'
-
9
"
15'-11"3'-5 3/4"2'-11"13'-8 1/2"
2'
-
7
1
/
8
"
12
'
-
6
"
13'-4"
8'
-
8
5
/
8
"
1'
-
6
7
/
8
"
5'
-
0
"
9'
-
8
3
/
4
"
7
1
/
4
"
4'
-
1
0
3
/
4
"
6'
-
9
1
/
4
"
27
'
-
0
"
12
'
-
1
0
5
/
8
"
6'
-
0
1
/
2
"
,
V
.
I
.
F
.
4'
-
9
5
/
8
"
4'
-
3
1
/
3
2
"
5'
-
1
1
1
/
2
"
,
V
.
I
.
F
.
14
'
-
5
1
/
8
"
,
V
.
I
.
F
.
4'
-
2
5
/
8
"
11
'
-
3
1
/
4
"
,
V
.
I
.
F
.
8'
-
4
1
/
2
"
,
V
.
I
.
F
.
5'
-
1
1
/
4
"
2'
-
8
1
/
4
"
11'-6 5/8"5"
2'-11 3/4"10'-6 1/8"
17'-1"
3'-7 1/8"1'-7 1/32"
1'-3 5/16"
22'-5 1/4"
4 31/32"
1'-7"4'-0 5/32"3'-0"10'-6 15/16"
11
'
-
4
3
/
4
"
2'
-
1
1
"
3'
-
0
1
9
/
3
2
"
2'
-
6
1
1
/
1
6
"
5'
-
1
0
2
1
/
3
2
"
5'-3 7/32"4'-10 25/32"
11
'
-
3
"
2'
-
8
1
/
4
"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
V.
I
.
F
.
4'-11 3/32"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
4'-11 3/32"
2'-11 1/2"3'-6 1/4"
7 3/4"
2'-0"2'-0"2'-6 1/2"
9
1
/
2
"
2'
-
1
1
/
4
"
2'
-
1
0
1
/
4
"
2'
-
6
"
8'
-
8
3
/
8
"
,
V
.
I
.
F
.
V.
I
.
F
.
2'
-
9
1
/
2
"
10
'
-
9
"
3'-5 3/8"
11 5/32"
2'-6"7'-3 1/2", V.I.F.15'-8 1/4"
3'-0"
2'-9 1/2"
2'
-
0
3
/
8
"
2'
-
0
"
3'-8 1/4"3'-4"
1
1
/
2
"
O
F
F
G
R
I
D
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
2'
-
1
1
1
/
4
"
5
1
/
8
"
2'
-
9
"
15'-11"3'-5 3/4"2'-11"13'-8 1/2"
2'
-
7
1
/
8
"
12
'
-
6
"
13'-4"
8'
-
8
5
/
8
"
1'
-
6
7
/
8
"
5'
-
0
"
9'
-
8
3
/
4
"
7
1
/
4
"
4'
-
1
0
3
/
4
"
6'
-
9
1
/
4
"
27
'
-
0
"
12
'
-
1
0
5
/
8
"
6'
-
0
1
/
2
"
,
V
.
I
.
F
.
4'
-
9
5
/
8
"
4'
-
3
1
/
3
2
"
5'
-
1
1
1
/
2
"
,
V
.
I
.
F
.
14
'
-
5
1
/
8
"
,
V
.
I
.
F
.
4'
-
2
5
/
8
"
11
'
-
3
1
/
4
"
,
V
.
I
.
F
.
8'
-
4
1
/
2
"
,
V
.
I
.
F
.
5'
-
1
1
/
4
"
2'
-
8
1
/
4
"
11'-6 5/8"5"
2'-11 3/4"10'-6 1/8"
17'-1"
3'-7 1/8"1'-7 1/32"
1'-3 5/16"
22'-5 1/4"
4 31/32"
1'-7"4'-0 5/32"3'-0"10'-6 15/16"
11
'
-
4
3
/
4
"
2'
-
1
1
"
3'
-
0
1
9
/
3
2
"
2'
-
6
1
1
/
1
6
"
5'
-
1
0
2
1
/
3
2
"
5'-3 7/32"4'-10 25/32"
11
'
-
3
"
2'
-
8
1
/
4
"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
V.
I
.
F
.
4'-11 3/32"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
4'-11 3/32"
2'-11 1/2"3'-6 1/4"
7 3/4"
2'-0"2'-0"2'-6 1/2"
9
1
/
2
"
2'
-
1
1
/
4
"
2'
-
1
0
1
/
4
"
2'
-
6
"
8'
-
8
3
/
8
"
,
V
.
I
.
F
.
V.
I
.
F
.
2'
-
9
1
/
2
"
10
'
-
9
"
3'-5 3/8"
11 5/32"
2'-6"7'-3 1/2", V.I.F.15'-8 1/4"
3'-0"
2'-9 1/2"
2'
-
0
3
/
8
"
2'
-
0
"
3'-8 1/4"3'-4"
1
1
/
2
"
O
F
F
G
R
I
D
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
3'
-
1
0
1
/
2
"
4'
-
8
1
/
4
"
4'-3"4'-6 1/4"4'-10"
2'
-
6
3
/
4
"
APARTMENT FLOOR AREA
1363.20 SQ. FT.
FLOOR AREA CALCULATIONS
EXISTING LOWER LEVEL FLOOR AREA CALCULATIONS
GROSS FLOOR AREA 1363.20 SQ. FT.
COUNTABLE FLOOR AREA 1363.20 SQ. FT.( 1363.20 SQ. FT. x 100.00%)
EXISTING GARAGE FLOOR AREA CALCULATIONS
EXISTING GARAGE FLOOR AREA 0
EXEMPT GARAGE AREA (26.575.020.D.7)0
COUNTABLE GARAGE FLOOR AREA 0.00 SQ. FT.
EXISTING OVERHANG FLOOR AREA CALCULATIONS
EXISTING OVERHANG FLOOR AREA 0
OVERHANG COUNTABLE FLOOR AREA 0 SQ. FT.ONE STORY PROJECTION 26.575.D.5
EXISTING DECK AREA CALCULATIONS
EXISTING DECK AREA 200.49 SQ. FT.(88.9583 SQ. FT. FRONT DECK +
111.5278 SQ. FT. BACK DECK
EXEMPT DECK AREA (26.575.020.D.4)204.4799 SQ. FT.(1363.20 SQ. FT. SQ. FT. x 15%)
COUNTABLE DECK AREA 0
EXISTING FLOOR AREA CALCULATIONS
UNIT FLOOR AREA 1363.20 SQ. FT.
GARAGE FLOOR AREA 0.00 SQ. FT.
OVERHANG FLOOR AREA 0.00
COUNTABLE DECK AREA 0 SQ. FT.
TOTAL COUNTABLE FLOOR AREA 1363.20 SQ. FT. SQ. FT.
TOTAL ALLOWABLE FLOOR AREA 0.00 SQ. FT.
FLOOR AREA CALCULATIONS
EXISTING LOWER LEVEL FLOOR AREA CALCULATIONS
GROSS FLOOR AREA 1363.20 SQ. FT.
COUNTABLE FLOOR AREA 1363.20 SQ. FT.( 1363.20 SQ. FT. x 100.00%)
EXISTING GARAGE FLOOR AREA CALCULATIONS
EXISTING GARAGE FLOOR AREA 0
EXEMPT GARAGE AREA (26.575.020.D.7)0
COUNTABLE GARAGE FLOOR AREA 0.00 SQ. FT.
EXISTING OVERHANG FLOOR AREA CALCULATIONS
EXISTING OVERHANG FLOOR AREA 0
OVERHANG COUNTABLE FLOOR AREA 0 SQ. FT.ONE STORY PROJECTION 26.575.D.5
EXISTING DECK AREA CALCULATIONS
EXISTING DECK AREA 200.49 SQ. FT.(88.9583 SQ. FT. FRONT DECK +
111.5278 SQ. FT. BACK DECK
EXEMPT DECK AREA (26.575.020.D.4)204.4799 SQ. FT.(1363.20 SQ. FT. SQ. FT. x 15%)
COUNTABLE DECK AREA 0
EXISTING FLOOR AREA CALCULATIONS
UNIT FLOOR AREA 1363.20 SQ. FT.
GARAGE FLOOR AREA 0.00 SQ. FT.
OVERHANG FLOOR AREA 0.00
COUNTABLE DECK AREA 0 SQ. FT.
TOTAL COUNTABLE FLOOR AREA 1363.20 SQ. FT. SQ. FT.
TOTAL ALLOWABLE FLOOR AREA 0.00 SQ. FT.
PROJECT
SCALE
1/4" = 1'-0"
20020.00
Z-001
EXISTING AND
PROPOSED
FLOOR AREA
N
0 2 4 8
Scale: 1/4" = 1'-0"
PROPOSED
UNIT FLOOR AREA
1/4" = 1'-0"
1
Z-001
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
8
1
6
1
1
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
0
9
0
2
6
10
2
8
E
.
H
O
P
K
I
N
S
A
V
E
.
#
2
7
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
12/31/2020 RDS SET
1/11/2021 PERMIT SET
EXISTING
UNIT FLOOR AREA
1/4" = 1'-0"
1
Z-001
BEDROOM 2
108
BEDROOM 1
107
MASTER BEDROOM
104
DINING
102
KITCHEN
101
LIVING
103
ADJ. BUILDING HALLWAY
ADJ. BUILDING STAIR
NO
WORK
NO
WORK
HALL
109
CLOSETCLOSET
QUEEN
KING
BU
I
L
T
-
I
N
S
BUILT-INS
(E) 2- SIDED
WOOD F.P.;
NO CHANGE
WH
MASTER
BATH
105
BATH
106
BUILT-INS
TWIN
QUEEN
2'
-
1
1
1
/
4
"
5
1
/
8
"
2'
-
9
"
15'-11"3'-5 3/4"2'-11"13'-8 1/2"
2'
-
7
1
/
8
"
12
'
-
6
"
13'-4"
8'
-
8
5
/
8
"
1'
-
6
7
/
8
"
5'
-
0
"
9'
-
8
3
/
4
"
7
1
/
4
"
4'
-
1
0
3
/
4
"
6'
-
9
1
/
4
"
27
'
-
0
"
12
'
-
1
0
5
/
8
"
6'
-
0
1
/
2
"
,
V
.
I
.
F
.
4'
-
9
5
/
8
"
4'
-
3
1
/
3
2
"
5'
-
1
1
1
/
2
"
,
V
.
I
.
F
.
14
'
-
5
1
/
8
"
,
V
.
I
.
F
.
4'
-
2
5
/
8
"
11
'
-
3
1
/
4
"
,
V
.
I
.
F
.
8'
-
4
1
/
2
"
,
V
.
I
.
F
.
5'
-
1
1
/
4
"
2'
-
8
1
/
4
"
11'-6 5/8"5"
2'-11 3/4"10'-6 1/8"
17'-1"
3'-7 1/8"1'-7 1/32"
1'-3 5/16"
22'-5 1/4"
4 31/32"
1'-7"4'-0 5/32"3'-0"10'-6 15/16"
11
'
-
4
3
/
4
"
2'
-
1
1
"
3'
-
0
1
9
/
3
2
"
2'
-
6
1
1
/
1
6
"
5'
-
1
0
2
1
/
3
2
"
5'-3 7/32"4'-10 25/32"
11
'
-
3
"
2'
-
8
1
/
4
"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
V.
I
.
F
.
4'-11 3/32"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
4'-11 3/32"
2'-11 1/2"3'-6 1/4"
7 3/4"
2'-0"2'-0"2'-6 1/2"
9
1
/
2
"
2'
-
1
1
/
4
"
2'
-
1
0
1
/
4
"
2'
-
6
"
8'
-
8
3
/
8
"
,
V
.
I
.
F
.
V.
I
.
F
.
2'
-
9
1
/
2
"
10
'
-
9
"
3'-5 3/8"
11 5/32"
2'-6"7'-3 1/2", V.I.F.15'-8 1/4"
3'-0"
2'-9 1/2"
2'
-
0
3
/
8
"
2'
-
0
"
3'-8 1/4"3'-4"
1
1
/
2
"
O
F
F
G
R
I
D
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
101A
104A
104B
107A
107B
105A106A
108A
102A
103A
105A
107A
106A
108A
109A 109B108B
109C
104A
1 2 3 4
8 96
2 4
98
2 3
85
4
9
2 3
85
4
9
2 3
54
8
1 2
43
5 6
2 4
109
5
2 4
5
5
107
5
1
8
1
8
9
8NO
WORK
NO
WORK
BEDROOM 2
108
BEDROOM 1
107
MASTER BEDROOM
104
DINING
102
KITCHEN
101
LIVING
103
CLOSET
ADJ. BUILDING HALLWAY
ADJ. BUILDING STAIR
HALL
109
MASTER
BATH
105
BATH
106
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSETCLOSET
WH
(E) 2- SIDED
WOOD F.P.;
NO CHANGE
2'
-
1
1
1
/
4
"
5
1
/
8
"
2'
-
9
"
15'-11"3'-5 3/4"2'-11"13'-8 1/2"
2'
-
7
1
/
8
"
12
'
-
6
"
13'-4"
8'
-
8
5
/
8
"
1'
-
6
7
/
8
"
5'
-
0
"
9'
-
8
3
/
4
"
7
1
/
4
"
4'
-
1
0
3
/
4
"
6'
-
9
1
/
4
"
27
'
-
0
"
12
'
-
1
0
5
/
8
"
6'
-
0
1
/
2
"
,
V
.
I
.
F
.
4'
-
9
5
/
8
"
4'
-
3
1
/
3
2
"
5'
-
1
1
1
/
2
"
,
V
.
I
.
F
.
14
'
-
5
1
/
8
"
,
V
.
I
.
F
.
4'
-
2
5
/
8
"
11
'
-
3
1
/
4
"
,
V
.
I
.
F
.
8'
-
4
1
/
2
"
,
V
.
I
.
F
.
5'
-
1
1
/
4
"
2'
-
8
1
/
4
"
11'-6 5/8"5"
2'-11 3/4"10'-6 1/8"
17'-1"
3'-7 1/8"1'-7 1/32"
1'-3 5/16"
22'-5 1/4"
4 31/32"
1'-7"4'-0 5/32"3'-0"10'-6 15/16"
11
'
-
4
3
/
4
"
2'
-
1
1
"
3'
-
0
1
9
/
3
2
"
2'
-
6
1
1
/
1
6
"
5'
-
1
0
2
1
/
3
2
"
5'-3 7/32"4'-10 25/32"
11
'
-
3
"
2'
-
8
1
/
4
"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
V.
I
.
F
.
4'-11 3/32"
2'
-
0
"
5'
-
8
2
1
/
3
2
"
4'-11 3/32"
2'-11 1/2"3'-6 1/4"
7 3/4"
2'-0"2'-0"2'-6 1/2"
9
1
/
2
"
2'
-
1
1
/
4
"
2'
-
1
0
1
/
4
"
2'
-
6
"
8'
-
8
3
/
8
"
,
V
.
I
.
F
.
V.
I
.
F
.
2'
-
9
1
/
2
"
10
'
-
9
"
3'-5 3/8"
11 5/32"
2'-6"7'-3 1/2", V.I.F.15'-8 1/4"
3'-0"
2'-9 1/2"
2'
-
0
3
/
8
"
2'
-
0
"
3'-8 1/4"3'-4"
1
1
/
2
"
O
F
F
G
R
I
D
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
101A
104A
104B
107A
107B
105A106A
108A
102A
103A
105A
107A
106A
108A
109A 109B108B
101A
109C
104A
3'
-
1
0
1
/
2
"
4'
-
8
1
/
4
"
4'-3"4'-6 1/4"4'-10"
2'
-
6
3
/
4
"
1 2 3 4
8 9 106
2 4
109
2 3
95
4
10
2 3
95
4
10
2 3
94
10
1 2
43
6 9
2 4
109
7
2 4
9
N
0 2 4 8
Scale: 1/4" = 1'-0"
PROPOSED UNIT 27 FLOOR PLAN
1/4" = 1'-0"
1
A-101
PROJECT
SCALE
1/4" = 1'-0"
20020.00
A-101
EXISITING AND
PROPOSED UNIT
PLAN
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
8
1
6
1
1
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
0
9
0
2
6
10
2
8
E
.
H
O
P
K
I
N
S
A
V
E
.
#
2
7
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
12/31/2020 RDS SET
1/11/2021 PERMIT SETKEY NOTES
LEGEND: MAIN LEVEL EXISTING
REMOVE AND REPLACE WITH MATCHING CABINETRY1
REMOVE AND REPLACE DOOR2
REMOVE INTERIOR NONE STRUCTURAL WALLS FOR
NEW BUILT-IN CABINETRY
3
4
REMOVE AND REPLACE APPLIANCE(S)
5
UPDATE FIREPLACE MATERIALS
6
7
REMOVE AND REPLACE PLUMBING FIXTURES
8
9
10
REMOVE AND REPLACE LIGHTING (T.B.D.)
REMOVE AND REPLACE WINDOW
REMOVE AND REPLACE FLOORING
REMOVE AND REPLACE BLINDS
KEY NOTES
LEGEND: MAIN LEVEL PROPOSED
NEW CABINETRY1
NEW DOOR (EXTERIOR DOORS UPDATED TO
EFFICIENCY CODES)2
NEW WALL AND.OR CEILING PAINT
3
4
NEW LIGHTING TO BE INSTALLED (T.B.D.)
5
NEW EFFICIENT APPLIANCE(S)
6
7
UPDATED PLUMBING FIXTURE TO EFFICIENCY CODES
8
9
NEW FIREPLACE SURROUND10
NEW SHADES
11
NEW WINDOW TO EFFICIENCY CODES
NEW FLOORING
NEW SWITCH/ OUTLET WALL PLATES TO BE INSTALLED
SEE G0.00 FOR SYMBOLS
NOT SHOWN HERE.
DOOR NUMBER
WINDOW NUMBER
SECTION DETAIL
ENLARGED DETAIL
DETAIL NUMBER
SHEET NUMBER
X
X
X
X
XX
XX
LEGEND
EXISTING UNIT 27 FLOOR PLAN
1/4" = 1'-0"
2
A-101
BEDROOM 2
108
BEDROOM 1
107
MASTER BEDROOM
104
DINING
102
KITCHEN
101
LIVING
103
ADJ. BUILDING HALLWAY
ADJ. BUILDING STAIR
NO
WORK
NO
WORK
HALL
109
CLOSETCLOSET
BU
I
L
T
-
I
N
S
BUILT-INS
(E) 2- SIDED
WOOD F.P.;
NO CHANGE
WH
MASTER
BATH
105
BATH
106
BUILT-INS
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
SKYLIGHT
X'-X" GB
X'-X" GB
X'-X" GB
X'-X" GB
X'-X" GB
X'-X" GB
FF
SD
SD
SD
8'-0" GB
8'-0" GB8'-0" GB
X'-X" GB
X'-X" GB
NO
WORK
NO
WORK
BEDROOM 2
108
BEDROOM 1
107
MASTER BEDROOM
104
DINING
102
KITCHEN
101
LIVING
103
CLOSET
ADJ. BUILDING HALLWAY
ADJ. BUILDING STAIR
HALL
109
MASTER
BATH
105
BATH
106
CLOSET
CLOSET
CLOSET
CLOSET
CLOSET
CLOSETCLOSET
WH
(E) 2- SIDED
WOOD F.P.;
NO CHANGE
1 2 4 5 6 9
A
B
C
D
E
F
G
H
I
J
1 3 7 8
SKYLIGHT
X'-X" GB
8'-0" GB
X'-X" GB
X'-X" GB
X'-X" GB
8'-0" GB8'-0" GB
X'-X" GB
X'-X" GB
SD
SD
SD
X'-X" GB
X'-X" GB
N
0 2 4 8
Scale: 1/4" = 1'-0"
PROPOSED APARTMENT FLOOR PLAN
1/4" = 1'-0"
1
A-102
PROJECT
SCALE
1/4" = 1'-0"
20020.00
A-102
EXISTING AND
PROPOSED RCP
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
8
1
6
1
1
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
0
9
0
2
6
10
2
8
E
.
H
O
P
K
I
N
S
A
V
E
.
#
2
7
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
12/31/2020 RDS SET
1/11/2021 PERMIT SET
EXISTING APARTMENT FLOOR PLAN
1/4" = 1'-0"
2
A-102
LEGEND SEE COVER SHEET FOR
SYMBOLS NOT SHOWN HERE.
REFLECTED CEILING PLAN
GENERAL NOTES
SP
ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED
OTHERWISE.
VERIFY IN FIELD ALL EXISTING DIMENSIONS.
LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING
DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING.
ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP.
PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN
WHICH THEY APPEAR.
COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE.
1.
2.
3.
4.
5.
6.
+8'-0"
SEE LIGHTING DRAWINGS FOR ALL LIGHT
SYMBOLS
SD
AIR OUTLET, VERIFY WITH MECH. SUB.
AIR INTAKE, VERIFY WITH MECH. SUB.
CEILING MOUNTED SMOKE DETECTOR
SPEAKER, VERIFY AV REQUIREMENTS
WITH OWNER
CEILING/SOFFIT HEIGHT SYMBOL
LOWER LEVEL
T.O. PLY
89'- 0"
LOWER LEVEL
T.O. PLY
89'- 0"
SLIDER WINDOW
KITCVHEN - 101101-A
UNIT 27 T.O. PLY
100'-0" VIF
SLIDER WINDOW
MASTER BEDROOM - 104104-A
SLIDER WINDOW
MASTER BEDROOM - 104104-B
SLIDER WINDOW
MASTER BATH - 105105-A
SLIDER WINDOW
BATH - 106106-A
SLIDER WINDOW
BEDROOM - 1101-A
UNIT 27 T.O. PLY
100'-0" VIF
SLIDER WINDOW
BEDROOM - 1101-A
SLIDER WINDOW
BEDROOM - 2101-A
3'
-
1
1
1
3
/
3
2
"
V
I
F
2'-11 1/4" VIF
4'
-
1
1
5
/
3
2
"
V
I
F
4'
-
1
1
5
/
3
2
"
V
I
F
5'-11 1/2" VIF
4'
-
1
1
3
/
4
"
V
I
F
3'-0" VIF
1'
-
8
"
V
I
F
1'-7" VIF
1'
-
8
"
V
I
F
1'-7 1/32" VIF
6'
-
7
3
/
8
"
V
I
F
8'-8 5/8" VIF
6'
-
7
"
V
I
F
5'-9 1/2" VIF
4'
-
1
1
1
/
4
"
V
I
F
5'-0" VIF
4'
-
1
1
1
/
4
"
V
I
F
4'-10 3/4" VIF
4'
-
1
1
1
/
4
"
V
I
F
2'-11 3/4" VIF
2'-0" VIF 2'-0" VIF 2'-6" VIF2'-0" VIF2'-0" VIF
6'
-
8
"
V
I
F
6'
-
8
"
V
I
F
6'
-
8
"
V
I
F
6'
-
8
"
V
I
F
6'
-
8
"
V
I
F
EX
T
E
R
I
O
R
IN
T
E
R
I
O
R
3-PANEL MULTISLIDE DOOR
LIVING ROOM - 103103-A
INTERIOR DOOR
MASTER BATH - 105105-A
INTERIOR DOOR
BATH - 106106-A
2-PANEL MULTISLIDE DOOR
DINING ROOM - 102102-A
NEW EXTERIOR DOORS
AND WINDOWS TO
MEET OR EXCEED CITY
APPLICABLE CODE
EXPECTATIONS, TYP.
NEW TRU, SOLID CORE
1 3/4" DOORS, WITH
STANDARD JAMB, TYP.
INTERIOR DOOR
HALL - 109 109-A
INTERIOR DOOR
HALL - 109109-B INTERIOR DOOR
HALL - 109109-C
3'
-
4
1
/
2
"
V
I
F
2'
-
9
1
/
8
"
V
I
F
5'
-
0
"
V
I
F
9
1
/
2
"
V
I
F
TT
4'-11 3/32" VIF
7'
-
0
"
V
I
F
4'-11 3/32" VIF
7'
-
0
"
V
I
F
GLASS SHOWER DOOR
MASTER BATH - 105105-B
GLASS SHOWER DOOR
BATH - 106106-B
TT
2'
-
9
1
/
2
"
V
I
F
2'
-
9
1
/
4
"
V
I
F
2'
-
9
3
/
4
"
V
I
F
2'
-
9
3
/
4
"
V
I
F
9
1
/
2
"
V
I
F
0 1 2 4
Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0"
PROJECT
SCALE
1/2" = 1'-0"
20020.00
A-601
WINDOW AND
DOOR
SCHEDULE
CO
P
Y
R
I
G
H
T
2
0
2
0
T
H
U
N
D
E
R
B
O
W
L
A
R
C
H
I
T
E
C
T
S
AS
P
E
N
,
C
O
8
1
6
1
1
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
0
9
0
2
6
10
2
8
E
.
H
O
P
K
I
N
S
A
V
E
.
#
2
7
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
12/31/2020 RDS SET
1/11/2021 PERMIT SET
1.CONTRACTOR TO VERIFY ALL ROUGH OPENING SIZES AND WALL DEPTHS IN FIELD
PRIOR TO PURCHASE OF WINDOWS AND DOORS. CONTACT ARCHITECT IF THERE
ARE DISCREPANCIES OR QUESTIONS.
2.CONTRACTOR TO INSTALL DOORS AND WINDOWS PER MANUFACTURERS
INSTALLATION GUIDELINES. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COST
INCURRED DUE TO IMPROPER INSTALLATION.
3.CONTRACTOR TO VERIFY FINISH/STAIN OF WINDOWS AND DOORS WITH THE
OWNER AND ARCHITECT PRIOR TO PURCHASE.
4.TEMP. OR T INDICATES ALL DOORS AND WINDOWS TO BE INSTALLED WITH
TEMPERED GLAZING.
5.ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL.
6.HARDWARE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER HARDWARE
INCLUDING BRACKETS, STRIKES, ETC. SUBMIT COMPLETE HARDWARE REVIEW FOR
ARCHITECT'S/OWNER'S REVIEW.
7.ALL DOOR AND WINDOW HINGES TO MATCH HARDWARE, CONFIRM FINISH WITH
OWNER AND THE ARCHITECT PRIOR TO INSTALLATION.
8.GLASS SHOULD BE TEMPERED WHEN DOOR AND ENCLOSURES OF BATHTUBS, SPAS,
HOT TUBS ARE: WITHIN 24" ARC OF A DOOR, WITHIN 36" HORIZONTALLY OF A
WALKING SURFACE WHEN THE GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE
OF THE ADJACENT WALKING SURFACE, OR WITHIN 60 HORIZONTALLY OF THE
BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE GLASS IS LESS
THAN 60 INCHES ABOVE THE NOSE OF THE TREAD AND DOORS, SLIDING GLASS
DOORS AND SKYLIGHTS
9.CONTRACTOR TO VERIFY ALL ROUGH OPENING SIZES WITH WINDOW
MANUFACTURER BASED ON PROVIDED SASH DIMENSIONS.
10.VERIFY OPERABILITY OF WINDOWS PER PLAN KEY.
11.CONTRACTOR TO VERIFY ALL EXISTING SILL HEIGHTS AND HEADER HEIGHTS. NEW
WINDOWS AND DOORS TO MATCH EXISTING HEIGHTS AND OPENINGS U.O.N.
SEE G0.00 FOR SYMBOLS
NOT SHOWN HERE.
DOOR AND WINDOW
GENERAL NOTES
REVISION-
DOOR NUMBER
WINDOW NUMBER
SECTION DETAIL
ENLARGED DETAIL
DETAIL NUMBER
SHEET NUMBER
X
X
X
X
XX
XX
TEMPEREDTTEMP. OR
LEGEND
WINDOW TYPE
ROOM NAME - ####
DOOR TYPE
ROOM NAME - ####