Loading...
HomeMy WebLinkAbout90.Architectural Plans.2021.01.11CIVIL ENGINEER: - CONTACT: - - COL. C.O. CEILING HEIGHT A.F.F.+13'-11" PROJECT ADDRESS: PARCEL ID: FIRE SPRINKLER SYSTEM INSTALLED: APPLICABLE CODES: ·2015 IRC (International Residential Code) Chapters 1-10 ·2015 IRC appendixes: ·Manufactured homes, F: Radon, J: Existing Buildings & Structures, H:Patio Covers, K: Sound Transmission. ·2015 IPC (International Plumbing Code) ·2015 IMC (International Mechanical Code) ·2015 IFGC (International Fuel Gas Code) ·2015 IECC (International Energy Conservation Code) - Prescriptive Path ·2015 IFC (International Fire Code) ·2015 NEC (National Electrical Code) 1028 E. Hopkins Ave. #27, Aspen CO 81611 273718109026 NO R-15 XX sq ft EXISTING, XX sq ft PROPOSED (NO CHANGE) Residential Front - 25', Side and Rear - 10' ZONING: F.A.R. PERMITTED USE: SETBACKS: Tread Terrazzo Thick Tempered TEL. T.C. T.B. T. THK. T.M.E. T.O.C. T.&G. TER. TEMP. To Match Existing Top of Concrete Towel Bar Top of Curb Telephone Tongue & Groove Typical Varies UnfinishedUNF. V.C.T. VAR. U.O.N. UNEXC. U.B.C. T.O. PLY T.O.W. TYP. Veneer Vertical Vestibule Volume Wood West With V.I.F. W.C. WD. W.H. W. W/ V.G.D.F. VOL. VERT. VEST. VEN. Wall Covering Water Heater Vertical Grain Douglas Fir Verify in Field Vinyl Composition Tile Top of Plywood Top of Wall Uniform Building Code Unexcavated Unless Otherwise Noted Top of PlateT.O.P. Wainscot Weight W.P. WW. WR. WT. W.S.P. W.P.M. WSCT. Welded Wire Work Point or Waterproofing Waterproof Membrane Wet Standpipe Water Resistant WithoutW/O REQ. RESIL. REINF. REG. REV. RWD. REMOV. R.O. RM. RET. Rough Opening Redwood Required Removable Room Resilient Retaining Reinforced Register Mounted Mullion Nominal North Number New Not to Scale Miscellaneous Not in Contract S.C.D. S.D. S. S.A.F.F SEP. SHT. S.H. SECT. S.E.D. SCHED. Separation Sprinkler Head Sheet See Civil Drawings Soap Dispenser/Dish See Electrical Drawings Storm Drain, Schedule Section Self-Adhesive Flexible Flashing South S.G.D. S.L.D. SHTG. S.C.D. SL. SIM. S.P.D. SPEC. S.M.D. S.S. SQ. S.LT.D. Stainless Steel Square See Lighting Drawings See Garage Drawings See Plumbing Drawings See Civil Drawings Sheathing Sliding Similar Opposite Opening On Center Overall Plaster Plywood Perimeter Plate Plastic Laminate Outside Diameter (Dim.) Point Paint Quarry Tile Partition Painted Paper Towel Receptacle Per Square Inch Pressure Treated Post Tensioned Paper Towel Dispenser Panel MUL. MISC. MTD. NOM. N.T.S. N.I.C. N. (N) Hardware Hardwood Hanger Height Horizontal Handrail Hour Hot Water Heater Hollow Metal HGT. HDW. HDWD. HGR. H.W.H. HORIZ. HR. H.R. H.M. Floor Drain Fire Extinguisher Cabinet Flat Bar Fixture Floor Srew Finish Flat Head Wood Screw Flat Head Machine OPP. O.A. O.C. O.D. PLAS. PL. Insulation Interior Inch Kitchen Joist Joint Janitor Junction Box Intermediate P.S.I. PNT. PT. P.T. P.T.R. P.T.D. PTN. Q.T. PTD. Laminate Lavatory Pound Linear Light Maintain Material Maximum Machine PNL. INTER. IN. INSUL. INT. KIT. JST. JB JT. JAN. Fluorescent Face of Finish Face of Plywood Face of Stud Footing Furring Future Frame Foot or Feet Fireproof Face of Concrete LB. LIN. LT. LAM. LAV. MAINT. MAT. MAX. MACH. General Gauge Gas Outlet Galvanized Ground Grade Glass Interrupt Ground Fault Galvanized Sheet Garbage Disposal Flashing Inside DiameterI.D. ABBREVIATIONS P.LAM. PLYWD. PERIM. OPNG. NO. or # STOR. STRL. STD. STL. S.V. SYS. SYM. S.W. System Steel Structural Sheet Vinyl Shear Wall Symmetrical Storage StandardReturn Air Recessed Radius Riser Reference Reflected Refrigerator REC. RAD. R.A. R. REFR. REFL. REF. Overlay Mechanical Membrane Minimum Metal Machine Bolt Medicine Cabinet Medium Density Manufacturer M.D.O. MEMB. MECH. M.B. M.C. MIN. MTL. MFR. Gypsum Handicapped Hose Bibb Hollow Core or Header Head Hardboard Metal S.S.D. See Structural Drawing Specification or Special See Landscape Drawings See Mechanical Drawings Revision/Revised/Reversed F.E. F.B. F.D. FIXT. FLR. F.H.W.S. FIN. F.H.M.S. CONSTR. CONN. COND. CONC. CTR. C.W. C.T. CONTR. CLOS. CONT. Center Cold Water Contractor Closet Ceramic Tile Condition Connection Construction Continuous Concrete F.O. Ply F.O.S. FLUOR. F.O.C. F.O.F. FURR. FUT. FTG. FR. FT. F.P.R.F. GALV. G.D. GEN. G. GA. GND. G.S.M. GR. GL. G.F.I. DIA. DIM. DBL. DET. D.F. DWG. DWR. D.W. DN. DR. DISP. E.J. EA. (E) E.I.F.S. E.O.S. ENCL. E.P.B. ELEC. EMER. EL. Dishwasher Edge of Slab Electrical Panel Board Enclosure Exterior Insulation & Elevation Electrical Emergency Existing Finish System Expansion Joint Each Drawing Drawer Drinking Fountain Dispenser Down Door Double Diameter Dimension Detail FLASH. At@ & < A.C. # 0 ACOUS. ALUM. ALT. ADJ. AGGR. ADJAC. BITUM. BD. ARCH. ASPH. APPROX. BM. B.O. BOT BLKG. BLK. C.B. CEM. CER. B.P. BTWN. BLDG. A.D. Catch Basin Cement Ceramic Beam Bottom of Building Paper Between Bottom Building Blocking Bituminous Board Block Diameter or Round Air Conditioning or Asphaltic Concrete Aluminum Approximate Architectural Asphalt Alternate Acoustical Area Drain Adjustable Aggregate Adjacent Pound or Number Angle And H.B. H.C. GYP. HDR. HDBD. HD. EXP. EXT. EXIST. EQUIP. F.A.U. F.A. Forced Air Unit Fire Alarm Equipment Existing Expansion Exterior CLKG. C.M.U. CLR. CLG. CNTR. Column Concrete Masonry Caulking Clean-Out Counter Unit Clear Ceiling C.J. Control Joint EqualEQ. PROJECT DIRECTORYVICINITY PLAN CONTACT: Ryan Doremus STRUCTURAL ENGINEER: LANDSCAPE DESIGN: OWNER/CLIENT: ARCHITECT: Aspen, CO 81611 Thunderbowl Architects 300 Spring St. Suite 201 Email: ryan@thunderbowlarchitects.com MJJ 2020 LLC SHEET NUMBER INTERIOR ELEVATION NUMBERS SYMBOLS 3 A6.1 1 A4.3 DOOR SYMBOL14 1A A 3 A6.1 DETAIL NUMBER SHEET NUMBER WINDOW SYMBOL PARTITION TYPE SHEET NUMBER BUILDING SECTION NUMBER SHEET NUMBER ENLARGED DETAIL NUMBER HOSE BIBB REVISION COLOR FINISH MATERIAL HB JB XX X 1 (N)/(E) CONSTRUCTION JUNCTION BOX Aspen, Colorado 1028 E. HOPKINS AVE. #27 GENERAL NOTES PROJECT STATISTICS TYPE: OCCUPANCY: OVERALL PROJECT HEIGHT AND AREA: PROJECT SUMMARY: Type V - Non-rated Type R-3 Maximum Height N/A - Area N/A INTERIOR UPDATES TO KITCHEN CABINETS AND ROOM CLOSETS; UPGRADING WINDOWS, SLIDING DOORS AND PLUMBING FIXTURES TO CURRENT CODES AND EFFICIENCY REQUIREMENTS. NEW FINISHES TO FLOORS AND WALLS. - - CONTACT: - CONTRACTOR A5.2 1 2 3 4 FOR ALL DRAWINGS EXCEPT DETAILS DIMENSIONING KEY TICK LEADER DENOTES DIMENSION TO FRAMING DOT LEADER DENOTES DIMENSION TO GRIDLINE/< 2'-2"3'-6" ARROW LEADER DENOTES DIMENSION TO FINISH 3'-5" PERMIT SET January 11, 2021 SITE 1028 E. Hopkins Ave. Ave 27 ASPEN, COLORADO The work included under this contract consists of all labor, materials, transportation, tools and equipment necessary for the construction of the project leaving all work ready for use. The construction documents are the property of Thunderbowl Architects Inc and its Consultants and are to be used as instruments of service for construction of this project only. Use for any other purpose, without authorization, is not allowed. The plans indicate the general extent of new construction necessary for the work, but are not intended to be all-inclusive. All demolition and all new work necessary to allow for a finished job in accordance with the intention of the drawing is included regardless of whether shown on the drawings or mentioned in the notes. Any errors, omissions or conflicts found in the various parts of the construction documents shall be brought to the attention of the Architect and the Owner for clarification before proceeding with the work. The General Contractor shall maintain a current and complete set of the construction documents on the job site during all phases of construction for use of all the trades and shall provide all the subcontractors with current and complete construction documents as required including specifications and architectural supplementary instructions. The General Contractor shall verify and assume responsibility for all dimensions and site conditions. The General Contractor shall inspect the existing premises and take note of existing conditions prior to submitting prices. No claim shall be allowed for difficulties encountered which could have reasonably been inferred from such an examination. Written dimensions take precedence. Do not scale drawings. See SYMBOLS area of this sheet for dimension standards. All dimensions noted "verify" and "V.I.F." are to be checked by Contractor prior to construction. Immediately report any variances to the Architect for resolution, then coordinate resolution w/ all work of all trades. Coordinate all work with existing conditions, including but not limited to: irrigation pipes, electrical conduit, water lines, gas lines, drainage lines, etc. Notify Architect immediately of any conflicts. Provide adequate temporary support as necessary to assure the structural value or integrity of the building. Protect all existing building and site conditions to remain, including walls, cabinets, finishes, trees and shrubs, paving, etc. Details shown are typical. Similar details apply in similar conditions. Verify all architectural details with structural, civil, landscape and design/build drawings before ordering or installation of any work. All changes in floor materials occur at centerline of door or framed opening unless otherwise indicated on the drawings. Install all fixtures, equipment and materials per manufacturer's recommendations. Verify clearances for flues, vents, chases, soffits, fixtures, etc. before any construction, ordering of, or installation of any items of work. Sealant, caulking and flashing, etc. locations shown on drawings are not intended to be inclusive. Follow manufacturer's installation recommendations and standard industry and building practices. The General Contractor shall remove all rubbish and waste materials of all subcontractors and trades on a regular basis, and shall exercise a strict control over job cleaning to prevent any direct debris or dust from affecting, in any way, finished areas in or outside job site. Contractor shall leave premises and all affected areas clean and orderly, ready for occupancy. This includes cleaning of all glass (inside and outside) and frames, both new and existing. Any survey monuments within the area of construction shall be preserved or reset by a registered civil engineer or a licensed land surveyor. Verify all finish materials with the Architect and the Owner prior to installation. On site mock-ups of building assemblies, finish assemblies, paint and/or stain samples, etc. may be required for approval. Contractor to coordinate utilities shown on architectural drawings with electrical, plumbing, mechanical, and any other consultant drawings. Contractor to coordinate all the trades. Structural observation shall be required by the Engineer for structural conformance to the approved plans. It is the General Contractors responsibility to obtain inspections and special inspections as necessary. All construction to provide a waterproof, weather tight building. Contractor should flash and caulk as necessary to achieve this requirement. S. South Albright & Associates 402 Park Ave., Unit E Basalt, CO 81621 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. SHEET INDEX NOT INCLUDED IN THIS SET INCLUDED IN THIS SET DATES ISSUEDSHEETTITLE DELETED FROM SET MECHANICAL DESIGN: - - CONTACT: -Tel: (XXX) XXX-XXXX Email: Tel: (XXX) XXX-XXXX Email: Tel: (XXX) XXX-XXXX Email: Tel: (970) 927-4363 Email: jack@albright-associates.com Tel: (970) 274-1421 RD S S E T DE C . 3 1 , 2 0 2 0 G-001 COVER Tel: (970) 274-1421 CONTACT: Ryan Doremus (Thunderbowl Architects) Aspen, CO 81611 300 Spring St. Suite 201 Email: ryan@thunderbowlarchitects.com Garret Construction, Inc. CONTACT: Todd Cerrone 3892 Crystal Bridge Dr. Carbondale, CO 81623 Tel: (970) 948-3695 Email: todd@garretconstruction.com todd.cerrone@gmail.com Z-001 UNIT FLOOR AREA + CALCULATIONS A-101 UNIT EXISTING AND PROPOSED FLOOR PLANS G-001 UNIT FIRE AREA + CALCULATIONS A-102 UNIT EXISTING AND PROPOSED RCP A-601 WINDOW AND DOOR SCHEDULE CONTACT: Jack Albright PE R M I T S E T Ja n u a r y 1 1 , 2 0 2 1 PROJECT SCALE NTS 20020.00 G-000 COVER SHEET CO P Y R I G H T 2 0 2 0 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O 8 1 6 1 1 PA R C E L I D # 2 7 3 7 1 8 1 0 9 0 2 6 10 2 8 E . H O P K I N S A V E . # 2 7 C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 12/31/2020 RDS SET 1/11/2021 PERMIT SET BEDROOM 2 108 BEDROOM 1 107 MASTER BEDROOM 104 DINING 102 KITCHEN 101 LIVING 103 ADJ. BUILDING HALLWAY ADJ. BUILDING STAIR NO WORK NO WORK HALL 109 CLOSETCLOSET QUEEN KING BU I L T - I N S BUILT-INS (E) 2- SIDED WOOD F.P.; NO CHANGE WH MASTER BATH 105 BATH 106 BUILT-INS TWIN QUEEN 2' - 1 1 1 / 4 " 5 1 / 8 " 2' - 9 " 15'-11"3'-5 3/4"2'-11"13'-8 1/2" 2' - 7 1 / 8 " 12 ' - 6 " 13'-4" 8' - 8 5 / 8 " 1' - 6 7 / 8 " 5' - 0 " 9' - 8 3 / 4 " 7 1 / 4 " 4' - 1 0 3 / 4 " 6' - 9 1 / 4 " 27 ' - 0 " 12 ' - 1 0 5 / 8 " 6' - 0 1 / 2 " , V . I . F . 4' - 9 5 / 8 " 4' - 3 1 / 3 2 " 5' - 1 1 1 / 2 " , V . I . F . 14 ' - 5 1 / 8 " , V . I . F . 4' - 2 5 / 8 " 11 ' - 3 1 / 4 " , V . I . F . 8' - 4 1 / 2 " , V . I . F . 5' - 1 1 / 4 " 2' - 8 1 / 4 " 11'-6 5/8"5" 2'-11 3/4"10'-6 1/8" 17'-1" 3'-7 1/8"1'-7 1/32" 1'-3 5/16" 22'-5 1/4" 4 31/32" 1'-7"4'-0 5/32"3'-0"10'-6 15/16" 11 ' - 4 3 / 4 " 2' - 1 1 " 3' - 0 1 9 / 3 2 " 2' - 6 1 1 / 1 6 " 5' - 1 0 2 1 / 3 2 " 5'-3 7/32"4'-10 25/32" 11 ' - 3 " 2' - 8 1 / 4 " 2' - 0 " 5' - 8 2 1 / 3 2 " V. I . F . 4'-11 3/32" 2' - 0 " 5' - 8 2 1 / 3 2 " 4'-11 3/32" 2'-11 1/2"3'-6 1/4" 7 3/4" 2'-0"2'-0"2'-6 1/2" 9 1 / 2 " 2' - 1 1 / 4 " 2' - 1 0 1 / 4 " 2' - 6 " 8' - 8 3 / 8 " , V . I . F . V. I . F . 2' - 9 1 / 2 " 10 ' - 9 " 3'-5 3/8" 11 5/32" 2'-6"7'-3 1/2", V.I.F.15'-8 1/4" 3'-0" 2'-9 1/2" 2' - 0 3 / 8 " 2' - 0 " 3'-8 1/4"3'-4" 1 1 / 2 " O F F G R I D 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 UNIT FLOOR AREA 1374.66 SQ. FT. 2' - 1 1 1 / 4 " 5 1 / 8 " 2' - 9 " 15'-11"3'-5 3/4"2'-11"13'-8 1/2" 2' - 7 1 / 8 " 12 ' - 6 " 13'-4" 8' - 8 5 / 8 " 1' - 6 7 / 8 " 5' - 0 " 9' - 8 3 / 4 " 7 1 / 4 " 4' - 1 0 3 / 4 " 6' - 9 1 / 4 " 27 ' - 0 " 12 ' - 1 0 5 / 8 " 6' - 0 1 / 2 " , V . I . F . 4' - 9 5 / 8 " 4' - 3 1 / 3 2 " 5' - 1 1 1 / 2 " , V . I . F . 14 ' - 5 1 / 8 " , V . I . F . 4' - 2 5 / 8 " 11 ' - 3 1 / 4 " , V . I . F . 8' - 4 1 / 2 " , V . I . F . 5' - 1 1 / 4 " 2' - 8 1 / 4 " 11'-6 5/8"5" 2'-11 3/4"10'-6 1/8" 17'-1" 3'-7 1/8"1'-7 1/32" 1'-3 5/16" 22'-5 1/4" 4 31/32" 1'-7"4'-0 5/32"3'-0"10'-6 15/16" 11 ' - 4 3 / 4 " 2' - 1 1 " 3' - 0 1 9 / 3 2 " 2' - 6 1 1 / 1 6 " 5' - 1 0 2 1 / 3 2 " 5'-3 7/32"4'-10 25/32" 11 ' - 3 " 2' - 8 1 / 4 " 2' - 0 " 5' - 8 2 1 / 3 2 " V. I . F . 4'-11 3/32" 2' - 0 " 5' - 8 2 1 / 3 2 " 4'-11 3/32" 2'-11 1/2"3'-6 1/4" 7 3/4" 2'-0"2'-0"2'-6 1/2" 9 1 / 2 " 2' - 1 1 / 4 " 2' - 1 0 1 / 4 " 2' - 6 " 8' - 8 3 / 8 " , V . I . F . V. I . F . 2' - 9 1 / 2 " 10 ' - 9 " 3'-5 3/8" 11 5/32" 2'-6"7'-3 1/2", V.I.F.15'-8 1/4" 3'-0" 2'-9 1/2" 2' - 0 3 / 8 " 2' - 0 " 3'-8 1/4"3'-4" 1 1 / 2 " O F F G R I D 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 NO WORK NO WORK BEDROOM 2 108 BEDROOM 1 107 MASTER BEDROOM 104 DINING 102 KITCHEN 101 LIVING 103 CLOSET ADJ. BUILDING HALLWAY ADJ. BUILDING STAIR HALL 109 MASTER BATH 105 BATH 106 CLOSET CLOSET CLOSET CLOSET CLOSET CLOSETCLOSET WH (E) 2- SIDED WOOD F.P.; NO CHANGE 3' - 1 0 1 / 2 " 4' - 8 1 / 4 " 4'-3"4'-6 1/4"4'-10" 2' - 6 3 / 4 " UNIT FLOOR AREA 1374.66 SQ. FT. TOTAL SQUARE FOOTAGE OF FIRE AREA = 1374.66 SQ. FT. N 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED UNIT #27 FLOOR PLAN - NO CHANGE 1/4" = 1'-0" 1 G-001 PROJECT SCALE 1/4" = 1'-0" 20020.00 G-001 EXISTING AND PROPOSED FIRE AREA CO P Y R I G H T 2 0 2 0 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O 8 1 6 1 1 PA R C E L I D # 2 7 3 7 1 8 1 0 9 0 2 6 10 2 8 E . H O P K I N S A V E . # 2 7 C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 12/31/2020 RDS SET 1/11/2021 PERMIT SET EXISTING UNIT #27 FLOOR PLAN 1/4" = 1'-0" 1 G-001 AREA PLAN LEGEND PROPOSED FIRE AREA BEDROOM 2 108 BEDROOM 1 107 MASTER BEDROOM 104 DINING 102 KITCHEN 101 LIVING 103 ADJ. BUILDING HALLWAY ADJ. BUILDING STAIR NO WORK NO WORK HALL 109 CLOSETCLOSET QUEEN KING BU I L T - I N S BUILT-INS (E) 2- SIDED WOOD F.P.; NO CHANGE WH MASTER BATH 105 BATH 106 BUILT-INS TWIN QUEEN 2' - 1 1 1 / 4 " 5 1 / 8 " 2' - 9 " 15'-11"3'-5 3/4"2'-11"13'-8 1/2" 2' - 7 1 / 8 " 12 ' - 6 " 13'-4" 8' - 8 5 / 8 " 1' - 6 7 / 8 " 5' - 0 " 9' - 8 3 / 4 " 7 1 / 4 " 4' - 1 0 3 / 4 " 6' - 9 1 / 4 " 27 ' - 0 " 12 ' - 1 0 5 / 8 " 6' - 0 1 / 2 " , V . I . F . 4' - 9 5 / 8 " 4' - 3 1 / 3 2 " 5' - 1 1 1 / 2 " , V . I . F . 14 ' - 5 1 / 8 " , V . I . F . 4' - 2 5 / 8 " 11 ' - 3 1 / 4 " , V . I . F . 8' - 4 1 / 2 " , V . I . F . 5' - 1 1 / 4 " 2' - 8 1 / 4 " 11'-6 5/8"5" 2'-11 3/4"10'-6 1/8" 17'-1" 3'-7 1/8"1'-7 1/32" 1'-3 5/16" 22'-5 1/4" 4 31/32" 1'-7"4'-0 5/32"3'-0"10'-6 15/16" 11 ' - 4 3 / 4 " 2' - 1 1 " 3' - 0 1 9 / 3 2 " 2' - 6 1 1 / 1 6 " 5' - 1 0 2 1 / 3 2 " 5'-3 7/32"4'-10 25/32" 11 ' - 3 " 2' - 8 1 / 4 " 2' - 0 " 5' - 8 2 1 / 3 2 " V. I . F . 4'-11 3/32" 2' - 0 " 5' - 8 2 1 / 3 2 " 4'-11 3/32" 2'-11 1/2"3'-6 1/4" 7 3/4" 2'-0"2'-0"2'-6 1/2" 9 1 / 2 " 2' - 1 1 / 4 " 2' - 1 0 1 / 4 " 2' - 6 " 8' - 8 3 / 8 " , V . I . F . V. I . F . 2' - 9 1 / 2 " 10 ' - 9 " 3'-5 3/8" 11 5/32" 2'-6"7'-3 1/2", V.I.F.15'-8 1/4" 3'-0" 2'-9 1/2" 2' - 0 3 / 8 " 2' - 0 " 3'-8 1/4"3'-4" 1 1 / 2 " O F F G R I D 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 2' - 1 1 1 / 4 " 5 1 / 8 " 2' - 9 " 15'-11"3'-5 3/4"2'-11"13'-8 1/2" 2' - 7 1 / 8 " 12 ' - 6 " 13'-4" 8' - 8 5 / 8 " 1' - 6 7 / 8 " 5' - 0 " 9' - 8 3 / 4 " 7 1 / 4 " 4' - 1 0 3 / 4 " 6' - 9 1 / 4 " 27 ' - 0 " 12 ' - 1 0 5 / 8 " 6' - 0 1 / 2 " , V . I . F . 4' - 9 5 / 8 " 4' - 3 1 / 3 2 " 5' - 1 1 1 / 2 " , V . I . F . 14 ' - 5 1 / 8 " , V . I . F . 4' - 2 5 / 8 " 11 ' - 3 1 / 4 " , V . I . F . 8' - 4 1 / 2 " , V . I . F . 5' - 1 1 / 4 " 2' - 8 1 / 4 " 11'-6 5/8"5" 2'-11 3/4"10'-6 1/8" 17'-1" 3'-7 1/8"1'-7 1/32" 1'-3 5/16" 22'-5 1/4" 4 31/32" 1'-7"4'-0 5/32"3'-0"10'-6 15/16" 11 ' - 4 3 / 4 " 2' - 1 1 " 3' - 0 1 9 / 3 2 " 2' - 6 1 1 / 1 6 " 5' - 1 0 2 1 / 3 2 " 5'-3 7/32"4'-10 25/32" 11 ' - 3 " 2' - 8 1 / 4 " 2' - 0 " 5' - 8 2 1 / 3 2 " V. I . F . 4'-11 3/32" 2' - 0 " 5' - 8 2 1 / 3 2 " 4'-11 3/32" 2'-11 1/2"3'-6 1/4" 7 3/4" 2'-0"2'-0"2'-6 1/2" 9 1 / 2 " 2' - 1 1 / 4 " 2' - 1 0 1 / 4 " 2' - 6 " 8' - 8 3 / 8 " , V . I . F . V. I . F . 2' - 9 1 / 2 " 10 ' - 9 " 3'-5 3/8" 11 5/32" 2'-6"7'-3 1/2", V.I.F.15'-8 1/4" 3'-0" 2'-9 1/2" 2' - 0 3 / 8 " 2' - 0 " 3'-8 1/4"3'-4" 1 1 / 2 " O F F G R I D 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 3' - 1 0 1 / 2 " 4' - 8 1 / 4 " 4'-3"4'-6 1/4"4'-10" 2' - 6 3 / 4 " APARTMENT FLOOR AREA 1363.20 SQ. FT. FLOOR AREA CALCULATIONS EXISTING LOWER LEVEL FLOOR AREA CALCULATIONS GROSS FLOOR AREA 1363.20 SQ. FT. COUNTABLE FLOOR AREA 1363.20 SQ. FT.( 1363.20 SQ. FT. x 100.00%) EXISTING GARAGE FLOOR AREA CALCULATIONS EXISTING GARAGE FLOOR AREA 0 EXEMPT GARAGE AREA (26.575.020.D.7)0 COUNTABLE GARAGE FLOOR AREA 0.00 SQ. FT. EXISTING OVERHANG FLOOR AREA CALCULATIONS EXISTING OVERHANG FLOOR AREA 0 OVERHANG COUNTABLE FLOOR AREA 0 SQ. FT.ONE STORY PROJECTION 26.575.D.5 EXISTING DECK AREA CALCULATIONS EXISTING DECK AREA 200.49 SQ. FT.(88.9583 SQ. FT. FRONT DECK + 111.5278 SQ. FT. BACK DECK EXEMPT DECK AREA (26.575.020.D.4)204.4799 SQ. FT.(1363.20 SQ. FT. SQ. FT. x 15%) COUNTABLE DECK AREA 0 EXISTING FLOOR AREA CALCULATIONS UNIT FLOOR AREA 1363.20 SQ. FT. GARAGE FLOOR AREA 0.00 SQ. FT. OVERHANG FLOOR AREA 0.00 COUNTABLE DECK AREA 0 SQ. FT. TOTAL COUNTABLE FLOOR AREA 1363.20 SQ. FT. SQ. FT. TOTAL ALLOWABLE FLOOR AREA 0.00 SQ. FT. FLOOR AREA CALCULATIONS EXISTING LOWER LEVEL FLOOR AREA CALCULATIONS GROSS FLOOR AREA 1363.20 SQ. FT. COUNTABLE FLOOR AREA 1363.20 SQ. FT.( 1363.20 SQ. FT. x 100.00%) EXISTING GARAGE FLOOR AREA CALCULATIONS EXISTING GARAGE FLOOR AREA 0 EXEMPT GARAGE AREA (26.575.020.D.7)0 COUNTABLE GARAGE FLOOR AREA 0.00 SQ. FT. EXISTING OVERHANG FLOOR AREA CALCULATIONS EXISTING OVERHANG FLOOR AREA 0 OVERHANG COUNTABLE FLOOR AREA 0 SQ. FT.ONE STORY PROJECTION 26.575.D.5 EXISTING DECK AREA CALCULATIONS EXISTING DECK AREA 200.49 SQ. FT.(88.9583 SQ. FT. FRONT DECK + 111.5278 SQ. FT. BACK DECK EXEMPT DECK AREA (26.575.020.D.4)204.4799 SQ. FT.(1363.20 SQ. FT. SQ. FT. x 15%) COUNTABLE DECK AREA 0 EXISTING FLOOR AREA CALCULATIONS UNIT FLOOR AREA 1363.20 SQ. FT. GARAGE FLOOR AREA 0.00 SQ. FT. OVERHANG FLOOR AREA 0.00 COUNTABLE DECK AREA 0 SQ. FT. TOTAL COUNTABLE FLOOR AREA 1363.20 SQ. FT. SQ. FT. TOTAL ALLOWABLE FLOOR AREA 0.00 SQ. FT. PROJECT SCALE 1/4" = 1'-0" 20020.00 Z-001 EXISTING AND PROPOSED FLOOR AREA N 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED UNIT FLOOR AREA 1/4" = 1'-0" 1 Z-001 CO P Y R I G H T 2 0 2 0 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O 8 1 6 1 1 PA R C E L I D # 2 7 3 7 1 8 1 0 9 0 2 6 10 2 8 E . H O P K I N S A V E . # 2 7 C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 12/31/2020 RDS SET 1/11/2021 PERMIT SET EXISTING UNIT FLOOR AREA 1/4" = 1'-0" 1 Z-001 BEDROOM 2 108 BEDROOM 1 107 MASTER BEDROOM 104 DINING 102 KITCHEN 101 LIVING 103 ADJ. BUILDING HALLWAY ADJ. BUILDING STAIR NO WORK NO WORK HALL 109 CLOSETCLOSET QUEEN KING BU I L T - I N S BUILT-INS (E) 2- SIDED WOOD F.P.; NO CHANGE WH MASTER BATH 105 BATH 106 BUILT-INS TWIN QUEEN 2' - 1 1 1 / 4 " 5 1 / 8 " 2' - 9 " 15'-11"3'-5 3/4"2'-11"13'-8 1/2" 2' - 7 1 / 8 " 12 ' - 6 " 13'-4" 8' - 8 5 / 8 " 1' - 6 7 / 8 " 5' - 0 " 9' - 8 3 / 4 " 7 1 / 4 " 4' - 1 0 3 / 4 " 6' - 9 1 / 4 " 27 ' - 0 " 12 ' - 1 0 5 / 8 " 6' - 0 1 / 2 " , V . I . F . 4' - 9 5 / 8 " 4' - 3 1 / 3 2 " 5' - 1 1 1 / 2 " , V . I . F . 14 ' - 5 1 / 8 " , V . I . F . 4' - 2 5 / 8 " 11 ' - 3 1 / 4 " , V . I . F . 8' - 4 1 / 2 " , V . I . F . 5' - 1 1 / 4 " 2' - 8 1 / 4 " 11'-6 5/8"5" 2'-11 3/4"10'-6 1/8" 17'-1" 3'-7 1/8"1'-7 1/32" 1'-3 5/16" 22'-5 1/4" 4 31/32" 1'-7"4'-0 5/32"3'-0"10'-6 15/16" 11 ' - 4 3 / 4 " 2' - 1 1 " 3' - 0 1 9 / 3 2 " 2' - 6 1 1 / 1 6 " 5' - 1 0 2 1 / 3 2 " 5'-3 7/32"4'-10 25/32" 11 ' - 3 " 2' - 8 1 / 4 " 2' - 0 " 5' - 8 2 1 / 3 2 " V. I . F . 4'-11 3/32" 2' - 0 " 5' - 8 2 1 / 3 2 " 4'-11 3/32" 2'-11 1/2"3'-6 1/4" 7 3/4" 2'-0"2'-0"2'-6 1/2" 9 1 / 2 " 2' - 1 1 / 4 " 2' - 1 0 1 / 4 " 2' - 6 " 8' - 8 3 / 8 " , V . I . F . V. I . F . 2' - 9 1 / 2 " 10 ' - 9 " 3'-5 3/8" 11 5/32" 2'-6"7'-3 1/2", V.I.F.15'-8 1/4" 3'-0" 2'-9 1/2" 2' - 0 3 / 8 " 2' - 0 " 3'-8 1/4"3'-4" 1 1 / 2 " O F F G R I D 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 101A 104A 104B 107A 107B 105A106A 108A 102A 103A 105A 107A 106A 108A 109A 109B108B 109C 104A 1 2 3 4 8 96 2 4 98 2 3 85 4 9 2 3 85 4 9 2 3 54 8 1 2 43 5 6 2 4 109 5 2 4 5 5 107 5 1 8 1 8 9 8NO WORK NO WORK BEDROOM 2 108 BEDROOM 1 107 MASTER BEDROOM 104 DINING 102 KITCHEN 101 LIVING 103 CLOSET ADJ. BUILDING HALLWAY ADJ. BUILDING STAIR HALL 109 MASTER BATH 105 BATH 106 CLOSET CLOSET CLOSET CLOSET CLOSET CLOSETCLOSET WH (E) 2- SIDED WOOD F.P.; NO CHANGE 2' - 1 1 1 / 4 " 5 1 / 8 " 2' - 9 " 15'-11"3'-5 3/4"2'-11"13'-8 1/2" 2' - 7 1 / 8 " 12 ' - 6 " 13'-4" 8' - 8 5 / 8 " 1' - 6 7 / 8 " 5' - 0 " 9' - 8 3 / 4 " 7 1 / 4 " 4' - 1 0 3 / 4 " 6' - 9 1 / 4 " 27 ' - 0 " 12 ' - 1 0 5 / 8 " 6' - 0 1 / 2 " , V . I . F . 4' - 9 5 / 8 " 4' - 3 1 / 3 2 " 5' - 1 1 1 / 2 " , V . I . F . 14 ' - 5 1 / 8 " , V . I . F . 4' - 2 5 / 8 " 11 ' - 3 1 / 4 " , V . I . F . 8' - 4 1 / 2 " , V . I . F . 5' - 1 1 / 4 " 2' - 8 1 / 4 " 11'-6 5/8"5" 2'-11 3/4"10'-6 1/8" 17'-1" 3'-7 1/8"1'-7 1/32" 1'-3 5/16" 22'-5 1/4" 4 31/32" 1'-7"4'-0 5/32"3'-0"10'-6 15/16" 11 ' - 4 3 / 4 " 2' - 1 1 " 3' - 0 1 9 / 3 2 " 2' - 6 1 1 / 1 6 " 5' - 1 0 2 1 / 3 2 " 5'-3 7/32"4'-10 25/32" 11 ' - 3 " 2' - 8 1 / 4 " 2' - 0 " 5' - 8 2 1 / 3 2 " V. I . F . 4'-11 3/32" 2' - 0 " 5' - 8 2 1 / 3 2 " 4'-11 3/32" 2'-11 1/2"3'-6 1/4" 7 3/4" 2'-0"2'-0"2'-6 1/2" 9 1 / 2 " 2' - 1 1 / 4 " 2' - 1 0 1 / 4 " 2' - 6 " 8' - 8 3 / 8 " , V . I . F . V. I . F . 2' - 9 1 / 2 " 10 ' - 9 " 3'-5 3/8" 11 5/32" 2'-6"7'-3 1/2", V.I.F.15'-8 1/4" 3'-0" 2'-9 1/2" 2' - 0 3 / 8 " 2' - 0 " 3'-8 1/4"3'-4" 1 1 / 2 " O F F G R I D 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 101A 104A 104B 107A 107B 105A106A 108A 102A 103A 105A 107A 106A 108A 109A 109B108B 101A 109C 104A 3' - 1 0 1 / 2 " 4' - 8 1 / 4 " 4'-3"4'-6 1/4"4'-10" 2' - 6 3 / 4 " 1 2 3 4 8 9 106 2 4 109 2 3 95 4 10 2 3 95 4 10 2 3 94 10 1 2 43 6 9 2 4 109 7 2 4 9 N 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED UNIT 27 FLOOR PLAN 1/4" = 1'-0" 1 A-101 PROJECT SCALE 1/4" = 1'-0" 20020.00 A-101 EXISITING AND PROPOSED UNIT PLAN CO P Y R I G H T 2 0 2 0 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O 8 1 6 1 1 PA R C E L I D # 2 7 3 7 1 8 1 0 9 0 2 6 10 2 8 E . H O P K I N S A V E . # 2 7 C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 12/31/2020 RDS SET 1/11/2021 PERMIT SETKEY NOTES LEGEND: MAIN LEVEL EXISTING REMOVE AND REPLACE WITH MATCHING CABINETRY1 REMOVE AND REPLACE DOOR2 REMOVE INTERIOR NONE STRUCTURAL WALLS FOR NEW BUILT-IN CABINETRY 3 4 REMOVE AND REPLACE APPLIANCE(S) 5 UPDATE FIREPLACE MATERIALS 6 7 REMOVE AND REPLACE PLUMBING FIXTURES 8 9 10 REMOVE AND REPLACE LIGHTING (T.B.D.) REMOVE AND REPLACE WINDOW REMOVE AND REPLACE FLOORING REMOVE AND REPLACE BLINDS KEY NOTES LEGEND: MAIN LEVEL PROPOSED NEW CABINETRY1 NEW DOOR (EXTERIOR DOORS UPDATED TO EFFICIENCY CODES)2 NEW WALL AND.OR CEILING PAINT 3 4 NEW LIGHTING TO BE INSTALLED (T.B.D.) 5 NEW EFFICIENT APPLIANCE(S) 6 7 UPDATED PLUMBING FIXTURE TO EFFICIENCY CODES 8 9 NEW FIREPLACE SURROUND10 NEW SHADES 11 NEW WINDOW TO EFFICIENCY CODES NEW FLOORING NEW SWITCH/ OUTLET WALL PLATES TO BE INSTALLED SEE G0.00 FOR SYMBOLS NOT SHOWN HERE. DOOR NUMBER WINDOW NUMBER SECTION DETAIL ENLARGED DETAIL DETAIL NUMBER SHEET NUMBER X X X X XX XX LEGEND EXISTING UNIT 27 FLOOR PLAN 1/4" = 1'-0" 2 A-101 BEDROOM 2 108 BEDROOM 1 107 MASTER BEDROOM 104 DINING 102 KITCHEN 101 LIVING 103 ADJ. BUILDING HALLWAY ADJ. BUILDING STAIR NO WORK NO WORK HALL 109 CLOSETCLOSET BU I L T - I N S BUILT-INS (E) 2- SIDED WOOD F.P.; NO CHANGE WH MASTER BATH 105 BATH 106 BUILT-INS 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 SKYLIGHT X'-X" GB X'-X" GB X'-X" GB X'-X" GB X'-X" GB X'-X" GB FF SD SD SD 8'-0" GB 8'-0" GB8'-0" GB X'-X" GB X'-X" GB NO WORK NO WORK BEDROOM 2 108 BEDROOM 1 107 MASTER BEDROOM 104 DINING 102 KITCHEN 101 LIVING 103 CLOSET ADJ. BUILDING HALLWAY ADJ. BUILDING STAIR HALL 109 MASTER BATH 105 BATH 106 CLOSET CLOSET CLOSET CLOSET CLOSET CLOSETCLOSET WH (E) 2- SIDED WOOD F.P.; NO CHANGE 1 2 4 5 6 9 A B C D E F G H I J 1 3 7 8 SKYLIGHT X'-X" GB 8'-0" GB X'-X" GB X'-X" GB X'-X" GB 8'-0" GB8'-0" GB X'-X" GB X'-X" GB SD SD SD X'-X" GB X'-X" GB N 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED APARTMENT FLOOR PLAN 1/4" = 1'-0" 1 A-102 PROJECT SCALE 1/4" = 1'-0" 20020.00 A-102 EXISTING AND PROPOSED RCP CO P Y R I G H T 2 0 2 0 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O 8 1 6 1 1 PA R C E L I D # 2 7 3 7 1 8 1 0 9 0 2 6 10 2 8 E . H O P K I N S A V E . # 2 7 C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 12/31/2020 RDS SET 1/11/2021 PERMIT SET EXISTING APARTMENT FLOOR PLAN 1/4" = 1'-0" 2 A-102 LEGEND SEE COVER SHEET FOR SYMBOLS NOT SHOWN HERE. REFLECTED CEILING PLAN GENERAL NOTES SP ALL DIMENSIONS ARE TO FACE OF FIN., CENTER OF FIXTURE/REGISTER UNLESS NOTED OTHERWISE. VERIFY IN FIELD ALL EXISTING DIMENSIONS. LIGHT FIXTURES SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY. SEE LIGHTING DRAWINGS FOR TYPE, LOCATION, AND CIRCUITING. ALSO SEE INTERIOR ELEVATIONS FOR LOCATION OF SCONCES, TYP. PAINT ALL RECESSED CAN TRIMS/MECHANICAL GRILLES THE COLOR OF THE CEILING IN WHICH THEY APPEAR. COORDINATE FIXTURE LAYOUT WITH ALL EXISTING AND PROPOSED STRUCTURE. 1. 2. 3. 4. 5. 6. +8'-0" SEE LIGHTING DRAWINGS FOR ALL LIGHT SYMBOLS SD AIR OUTLET, VERIFY WITH MECH. SUB. AIR INTAKE, VERIFY WITH MECH. SUB. CEILING MOUNTED SMOKE DETECTOR SPEAKER, VERIFY AV REQUIREMENTS WITH OWNER CEILING/SOFFIT HEIGHT SYMBOL LOWER LEVEL T.O. PLY 89'- 0" LOWER LEVEL T.O. PLY 89'- 0" SLIDER WINDOW KITCVHEN - 101101-A UNIT 27 T.O. PLY 100'-0" VIF SLIDER WINDOW MASTER BEDROOM - 104104-A SLIDER WINDOW MASTER BEDROOM - 104104-B SLIDER WINDOW MASTER BATH - 105105-A SLIDER WINDOW BATH - 106106-A SLIDER WINDOW BEDROOM - 1101-A UNIT 27 T.O. PLY 100'-0" VIF SLIDER WINDOW BEDROOM - 1101-A SLIDER WINDOW BEDROOM - 2101-A 3' - 1 1 1 3 / 3 2 " V I F 2'-11 1/4" VIF 4' - 1 1 5 / 3 2 " V I F 4' - 1 1 5 / 3 2 " V I F 5'-11 1/2" VIF 4' - 1 1 3 / 4 " V I F 3'-0" VIF 1' - 8 " V I F 1'-7" VIF 1' - 8 " V I F 1'-7 1/32" VIF 6' - 7 3 / 8 " V I F 8'-8 5/8" VIF 6' - 7 " V I F 5'-9 1/2" VIF 4' - 1 1 1 / 4 " V I F 5'-0" VIF 4' - 1 1 1 / 4 " V I F 4'-10 3/4" VIF 4' - 1 1 1 / 4 " V I F 2'-11 3/4" VIF 2'-0" VIF 2'-0" VIF 2'-6" VIF2'-0" VIF2'-0" VIF 6' - 8 " V I F 6' - 8 " V I F 6' - 8 " V I F 6' - 8 " V I F 6' - 8 " V I F EX T E R I O R IN T E R I O R 3-PANEL MULTISLIDE DOOR LIVING ROOM - 103103-A INTERIOR DOOR MASTER BATH - 105105-A INTERIOR DOOR BATH - 106106-A 2-PANEL MULTISLIDE DOOR DINING ROOM - 102102-A NEW EXTERIOR DOORS AND WINDOWS TO MEET OR EXCEED CITY APPLICABLE CODE EXPECTATIONS, TYP. NEW TRU, SOLID CORE 1 3/4" DOORS, WITH STANDARD JAMB, TYP. INTERIOR DOOR HALL - 109 109-A INTERIOR DOOR HALL - 109109-B INTERIOR DOOR HALL - 109109-C 3' - 4 1 / 2 " V I F 2' - 9 1 / 8 " V I F 5' - 0 " V I F 9 1 / 2 " V I F TT 4'-11 3/32" VIF 7' - 0 " V I F 4'-11 3/32" VIF 7' - 0 " V I F GLASS SHOWER DOOR MASTER BATH - 105105-B GLASS SHOWER DOOR BATH - 106106-B TT 2' - 9 1 / 2 " V I F 2' - 9 1 / 4 " V I F 2' - 9 3 / 4 " V I F 2' - 9 3 / 4 " V I F 9 1 / 2 " V I F 0 1 2 4 Scale: 1/2" = 1'-0"Scale: 1/2" = 1'-0" PROJECT SCALE 1/2" = 1'-0" 20020.00 A-601 WINDOW AND DOOR SCHEDULE CO P Y R I G H T 2 0 2 0 T H U N D E R B O W L A R C H I T E C T S AS P E N , C O 8 1 6 1 1 PA R C E L I D # 2 7 3 7 1 8 1 0 9 0 2 6 10 2 8 E . H O P K I N S A V E . # 2 7 C TH U N D E R B O W L AR C H I T E C T S THUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 12/31/2020 RDS SET 1/11/2021 PERMIT SET 1.CONTRACTOR TO VERIFY ALL ROUGH OPENING SIZES AND WALL DEPTHS IN FIELD PRIOR TO PURCHASE OF WINDOWS AND DOORS. CONTACT ARCHITECT IF THERE ARE DISCREPANCIES OR QUESTIONS. 2.CONTRACTOR TO INSTALL DOORS AND WINDOWS PER MANUFACTURERS INSTALLATION GUIDELINES. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COST INCURRED DUE TO IMPROPER INSTALLATION. 3.CONTRACTOR TO VERIFY FINISH/STAIN OF WINDOWS AND DOORS WITH THE OWNER AND ARCHITECT PRIOR TO PURCHASE. 4.TEMP. OR T INDICATES ALL DOORS AND WINDOWS TO BE INSTALLED WITH TEMPERED GLAZING. 5.ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL. 6.HARDWARE CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER HARDWARE INCLUDING BRACKETS, STRIKES, ETC. SUBMIT COMPLETE HARDWARE REVIEW FOR ARCHITECT'S/OWNER'S REVIEW. 7.ALL DOOR AND WINDOW HINGES TO MATCH HARDWARE, CONFIRM FINISH WITH OWNER AND THE ARCHITECT PRIOR TO INSTALLATION. 8.GLASS SHOULD BE TEMPERED WHEN DOOR AND ENCLOSURES OF BATHTUBS, SPAS, HOT TUBS ARE: WITHIN 24" ARC OF A DOOR, WITHIN 36" HORIZONTALLY OF A WALKING SURFACE WHEN THE GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE, OR WITHIN 60 HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE GLASS IS LESS THAN 60 INCHES ABOVE THE NOSE OF THE TREAD AND DOORS, SLIDING GLASS DOORS AND SKYLIGHTS 9.CONTRACTOR TO VERIFY ALL ROUGH OPENING SIZES WITH WINDOW MANUFACTURER BASED ON PROVIDED SASH DIMENSIONS. 10.VERIFY OPERABILITY OF WINDOWS PER PLAN KEY. 11.CONTRACTOR TO VERIFY ALL EXISTING SILL HEIGHTS AND HEADER HEIGHTS. NEW WINDOWS AND DOORS TO MATCH EXISTING HEIGHTS AND OPENINGS U.O.N. SEE G0.00 FOR SYMBOLS NOT SHOWN HERE. DOOR AND WINDOW GENERAL NOTES REVISION- DOOR NUMBER WINDOW NUMBER SECTION DETAIL ENLARGED DETAIL DETAIL NUMBER SHEET NUMBER X X X X XX XX TEMPEREDTTEMP. OR LEGEND WINDOW TYPE ROOM NAME - #### DOOR TYPE ROOM NAME - ####