Loading...
HomeMy WebLinkAboutExhibit B_1437 Crystal Lake Road_PlansC B A 5' - 1 " 2'-11" 7' - 0 " 2'-8" 1' - 1 " 3' - 1 " 1' - 3 1/ 4 " 4' - 1 0 " 4' - 2 3/ 4 " 5' - 1 1/ 2 " 4' - 2 3/ 4 " 3' - 2 " 17 18 101 102 T.O. EXISTING ROOF 118'-5" EXISTING UPPER LEVEL @ MASTER BED T.O. F.F. = 104'-10" EXISTING LOWER MAIN LEVEL T.O. F.F. = 95'-7 3/4" T.O. EXISTING CHIMNEY 121'-7" EXISTING MAIN LEVEL T.O. F.F. = 98'-8 3/4" EXISTING MAIN LEVEL ENTRY LANDING T.O. F.F. = 100'-0" EXISTING UPPER LEVEL @ GUEST BEDROOM T.O. F.F. = 109'-3/4" T.O. EXISTING ROOF 114'-2 1/4" EXISTING CRAWL SPACE T.O. GRADE = 94'-6 3/4" B A-301 A A-301 1 6 26 5 5 33 34 1) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3) ALL EXISTING WINDOWS TO REMAIN UNLESS NOTED OTHERWISE. 4) ALL EXISTING EXTERIOR MATERIALS TO REMAIN UNLESS NOTED OTHERWISE. ALL NEW EXTERIOR MATERIALS TO MATCH EXISTING. 5) ALL EXISTING ROOF HEIGHTS TO REMAIN. 6) EXISTING GRADE TO REMAIN IN ALL LOCATIONS. 7) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF FINISH FLOOR ON THE LOWER MAIN LEVEL. 8) VERIFY LOCATION OF TOP OF PLYWOOD IN FIELD GENERAL PLAN NOTES 0 2'4'8'SCALE: 1/4" = 1'-0" 1 PROPOSED NORTH ELEVATION DRAWING ISSUANCE INDEX ID NAME ISSUED DATE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 27 19 20 21 22 23 24 25 26 28 29 30 31 32 33 34 35 36 NEW SKYLIGHT TO BE INSTALLED EXISTING SKYLIGHT TO REMAIN LINE OF ROOF ABOVE COVERED DECK / PATIO PER RDS D.4 EXISTING ENTRY DOOR PER RDS.D.1 CHIMNEY TO REMAIN, STONE SIDING TO REMAIN AS NOTED EXISTING ROOF DRAIN TO REMAIN EXISTING FLAT TPO ROOF TO REMAIN, 1/4" PER 12" SLOPE TO DRAIN CHANGE IN CEILING HEIGHT EXISTING ROOF VENT TO REMAIN LINE OF WALL ABOVE LINE OF WALL BELOW EXISTING SKYLIGHT TO BE REMOVED NEW WINDOW NEW EXTERIOR DOOR EXISTING GRADE TO REMAIN UTILITY CLOSET, NOT IN SCOPE PARAPET WALL PATIO DRAIN EXISTING SPA TO BE REMOVED DECK TO BE REPAIRED TO MATCH EXISTING NEW PATIO EDGE DRAIN TO MATCH EXISTING EXISTING FIREPLACE FLUES TO REMAIN EXISTING WOOD BURNING FIREPLACE TO REMAIN, FACE TO BE RECLADDED BUILT-INS ZONE DISTRICT HEIGHT LIMIT LINE EXISTING STRUCTURAL COLUMN TO REMAIN STORAGE/CLOSET UNDER STAIRS PUNCH HOLE FOR SHOWER NICHE SHOWER BENCH SAFETY GLAZING AT SHOWER WALL PATCH ROOF AT REMOVED SKYLIGHT LOCATIONS HOOD VENT EXHAUST LOCATION PATIO WALL HANDRAIL GUARDRAIL STREAM MARGIN EXEMPTION 8/16/191 COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-201 ELEVATIONS 8/21/19 BL, JS 1829.00 Aspen CO 81611 1437 CRYSTAL LAKE RD FORUM PHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 North 4th Street Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 Exhibit B- Approved Changes DECK E 20' 24' 28' 20' 16' 12' 18' 16' 24' 30' 24' 12' 24' 16' 18' 24' 10' 16' 14' 16' 16' 16' 14' 20' 20' 16' 16' 16' 16' 12' 12' 12' 12' 12' 12' 12' 12' 16' 16' 12' 16' 16' 14' 16' 16' 16' 16' 12'12' 16' 12' 12' 16' 16' 12' 16' 24' 12' 14'-0" PUBLIC TRAIL EAS E M E N T T.O.FF 98'-71/4" T.O.FF 95'-6" T.O.FF 98'-83/4" T.O.FF 100'-0" T.O.FF 100'-0" T.O.FF 89'-63/4" T.O.FF 95'-73/4" STREAM MARGIN REVIEW AREA BOUNDARY LINE PER CITY OF ASPEN ENTRY OF NEIGHBORING UNIT UP D O W N 1433 CRYSTAL LAKE ROAD UNIT D5 1439 CRYSTAL LAKE ROAD UNIT E1 8005' 80 0 0 ' 8 0 0 0 ' DECK EXISTING DECK 8001 ' 8004' 80 0 3 ' 80 0 2 ' 8 0 0 0 ' 8006' 800 7 ' 8008 ' 8009 ' 8010 ' EXISTING DECK (NOT IN SCOPE) EXISTING DECK (NOT IN SCOPE) EXISTING PATIO TO REMAIN EXISTING FOOTPRINT TO REMAIN LEGAL ADDRESS: 1437 CRYSTAL LAKE ROAD UNIT: D6 ZONE DISTRICT: SPA R-15 PROJECT 100'-0" = 8010.7' T.O.CONC. 99'-81/4" PAVED PEDESTRIAN TRAIL PUBLIC TRAIL EASEMENT 2 2 EXISTING PAVED PEDESTRIAN TRAIL 2 6 20 8010' 801 0 ' 8011' 8 0 0 9 ' 8 0 0 8 ' 8008' 800 8 ' 1) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3) ALL EXISTING WINDOWS TO REMAIN UNLESS NOTED OTHERWISE. 4) ALL EXISTING EXTERIOR MATERIALS TO REMAIN UNLESS NOTED OTHERWISE. ALL NEW EXTERIOR MATERIALS TO MATCH EXISTING. 5) ALL EXISTING ROOF HEIGHTS TO REMAIN. 6) EXISTING GRADE TO REMAIN IN ALL LOCATIONS. 7) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF FINISH FLOOR ON THE LOWER MAIN LEVEL. 8) VERIFY LOCATION OF TOP OF PLYWOOD IN FIELD GENERAL PLAN NOTES E EXISTING CONIFEROUS TREE TO REMAIN EXISTING DECIDUOUS TREE TO REMAIN SITE PLAN LEGEND EXISTING ASPHALT/PAVEMENT EXISTING WALKWAY EXISTING EXTERIOR DECK SEWER LINE UNDERGROUND ELECTRIC LINE SANITORY MANHOLE ELECTRICAL METER CATV LINE EXISTING 1' CONTOUR PROPOSED 1' CONTOUR EXISTING 5' CONTOUR PROPOSED 5' CONTOUR TOPOGRAPHY LEGEND 1) ALL EXISTING TREES TO REMAIN 2) ALL EXISTING LIGHTING TO REMAIN, NO NEW EXTERIOR LIGHTING TO BE ADDED. SITE PLAN NOTES N04'8'12'SCALE: 3/16" = 1'-0" 1 EXISTING SITE PLAN AT GRADE DRAWING ISSUANCE INDEX ID NAME ISSUED DATE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 27 19 20 21 22 23 24 25 26 28 29 30 31 32 33 34 35 36 NEW SKYLIGHT TO BE INSTALLED EXISTING SKYLIGHT TO REMAIN LINE OF ROOF ABOVE COVERED DECK / PATIO PER RDS D.4 EXISTING ENTRY DOOR PER RDS.D.1 CHIMNEY TO REMAIN, STONE SIDING TO REMAIN AS NOTED EXISTING ROOF DRAIN TO REMAIN EXISTING FLAT TPO ROOF TO REMAIN, 1/4" PER 12" SLOPE TO DRAIN CHANGE IN CEILING HEIGHT EXISTING ROOF VENT TO REMAIN LINE OF WALL ABOVE LINE OF WALL BELOW EXISTING SKYLIGHT TO BE REMOVED NEW WINDOW NEW EXTERIOR DOOR EXISTING GRADE TO REMAIN UTILITY CLOSET, NOT IN SCOPE PARAPET WALL PATIO DRAIN EXISTING SPA TO BE REMOVED DECK TO BE REPAIRED TO MATCH EXISTING NEW PATIO EDGE DRAIN TO MATCH EXISTING EXISTING FIREPLACE FLUES TO REMAIN EXISTING WOOD BURNING FIREPLACE TO REMAIN, FACE TO BE RECLADDED BUILT-INS ZONE DISTRICT HEIGHT LIMIT LINE EXISTING STRUCTURAL COLUMN TO REMAIN STORAGE/CLOSET UNDER STAIRS PUNCH HOLE FOR SHOWER NICHE SHOWER BENCH SAFETY GLAZING AT SHOWER WALL PATCH ROOF AT REMOVED SKYLIGHT LOCATIONS HOOD VENT EXHAUST LOCATION PATIO WALL HANDRAIL GUARDRAIL STREAM MARGIN EXEMPTION 8/16/191 COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-001X EXISTING SITE PLAN AT GRADE 8/21/19 BL, JS 1829.00 Aspen CO 81611 1437 CRYSTAL LAKE RD FORUM PHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 North 4th Street Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 Exhibit B- Approved Changes D A-302 D A-302 UP W/ D 105 A 1 A-404 T.O. F.F. 98'-7" T.O. F.F. 95'-6" T.O. F.F. 100'-0" T.O. F.F. 98'-83/4" T.O. F.F. 98'-83/4" T.O.CONC. 99'-81/4" T.O. F.F. 95'-73/4" T.O. F.F. 98'-83/4" T.O.CONC. 99'-91/4" T.O. F.F. 100'-0" C A-302 C A-302 1 A-201 2 A-202 4 A-204 3 A-203 5 A-205 REF.WINE REF.DN DN ADJACENT UNIT UP UTILITY CLOSET 4 RISERS 7 11/32" EACH 1433 CRYSTAL LAKE ROAD UNIT D5 KITCHEN 102 ENTRY 101 LIVING ROOM 104 SITTING ROOM 105 BATH 107 LAUNDRY 106 ENTRY PATIO 10 2 10 1 1 1 2 2 3 3 4 4 5 5 C C B B A A 6 6 F F E E D D 1 A-401 7' - 4 " 18 ' - 2 " 36'-2" 25 ' - 6 " 10'-0" 7'-65/8" 6' - 1 0 " 3' - 0 1/ 3 2 " 17 ' - 3 25 / 3 2 " 9'-5" 3'-9"25'-71/2" 8'-11/4" 2' - 3 " 3' - 3 " 6' - 8 " 2' - 8 3/ 4 " 2' - 3 " 13'-8 5/16" 6 1/ 8 " 28 ' - 4 1/2 " 2'- 5 1/ 8 " 7'-10"5'-2"8'-8"18'-71/2" 40'-31/2" 5'- 1 1/2 " 14 ' - 0 " 19 ' - 1 1/ 2 " 21'-11/4" 43/4"12'-43/8"3'-9"61/8"9'-103/8"43/4"10'-103/4" 81/8" 71/ 2 " 7' - 2 " 2" 5" 17 ' - 1 1/ 8 " 77/ 8 " 2"61/8"7'-37/8"5'-0"2"61/8"8'-17/8"16'-81/8"71/2"1'-37/8"1'-6"81/8" 2'-8"3'-61/4"4'-0"11'-5" 12'-0" 21'-3 1/2" 2'-10 1/2" 1' - 5 " 1' - 5 " 6' - 1 0 " 63/ 4 " B A-301 B A-301 A A-301 A A-301 22 13 W - 2 W - 2 W- 5 B W-5B W-3 W-5A W-2 W- 2 W-2 W- 2 W-2 W- 2 24 24 25 25 23 2 2 2 27 W - EXT - WD 2X6 - METAL SIDING - SPRAY INSULATION W-5B 28 W- 5 B DINING ROOM 103 EXISTING TO REMAIN TO BE DEMOLISHED NEW WALL WALL LEGEND 1) EXISTING FRAMING & SHEATHING TO REMAIN AT AREAS NOT SHOWN AS DEMOLISHED. TYPICAL. 2) ALL DIMENSIONS TO EXISTING WALLS TO BE VERIFIED IN FIELD. TYPICAL. 3) ALL EXISTING WINDOWS TO REMAIN UNLESS NOTED OTHERWISE. 4) ALL EXISTING EXTERIOR MATERIALS TO REMAIN UNLESS NOTED OTHERWISE. ALL NEW EXTERIOR MATERIALS TO MATCH EXISTING. 5) ALL EXISTING ROOF HEIGHTS TO REMAIN. 6) EXISTING GRADE TO REMAIN IN ALL LOCATIONS. 7) VERIFY ALL EXISTING & PROPOSED SPOT ELEVATIONS IN FIELD. PROJECT 100'-0" IS IN RELATION TO EXISTING TOP OF FINISH FLOOR ON THE LOWER MAIN LEVEL. 8) VERIFY LOCATION OF TOP OF PLYWOOD IN FIELD GENERAL PLAN NOTES N02'4'8'SCALE: 1/4" = 1'-0" 1 PROPOSED MAIN LEVEL DRAWING ISSUANCE INDEX ID NAME ISSUED DATE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 27 19 20 21 22 23 24 25 26 28 29 30 31 32 33 34 35 36 NEW SKYLIGHT TO BE INSTALLED EXISTING SKYLIGHT TO REMAIN LINE OF ROOF ABOVE COVERED DECK / PATIO PER RDS D.4 EXISTING ENTRY DOOR PER RDS.D.1 CHIMNEY TO REMAIN, STONE SIDING TO REMAIN AS NOTED EXISTING ROOF DRAIN TO REMAIN EXISTING FLAT TPO ROOF TO REMAIN, 1/4" PER 12" SLOPE TO DRAIN CHANGE IN CEILING HEIGHT EXISTING ROOF VENT TO REMAIN LINE OF WALL ABOVE LINE OF WALL BELOW EXISTING SKYLIGHT TO BE REMOVED NEW WINDOW NEW EXTERIOR DOOR EXISTING GRADE TO REMAIN UTILITY CLOSET, NOT IN SCOPE PARAPET WALL PATIO DRAIN EXISTING SPA TO BE REMOVED DECK TO BE REPAIRED TO MATCH EXISTING NEW PATIO EDGE DRAIN TO MATCH EXISTING EXISTING FIREPLACE FLUES TO REMAIN EXISTING WOOD BURNING FIREPLACE TO REMAIN, FACE TO BE RECLADDED BUILT-INS ZONE DISTRICT HEIGHT LIMIT LINE EXISTING STRUCTURAL COLUMN TO REMAIN STORAGE/CLOSET UNDER STAIRS PUNCH HOLE FOR SHOWER NICHE SHOWER BENCH SAFETY GLAZING AT SHOWER WALL PATCH ROOF AT REMOVED SKYLIGHT LOCATIONS HOOD VENT EXHAUST LOCATION PATIO WALL HANDRAIL GUARDRAIL STREAM MARGIN EXEMPTION 8/16/191 COPYRIGHT KEYNOTE LEGEND PROJECT NO: DRAWN BY: FORUM PHI LLC DATE OF PUBLICATION A-101 PROPOSED MAIN LEVEL 8/21/19 BL, JS 1829.00 Aspen CO 81611 1437 CRYSTAL LAKE RD FORUM PHI Aspen: 715 West Main Street, #204 Aspen, Colorado 81611 Carbondale: 36 North 4th Street Carbondale, CO 81623 forumphi.com p: 970.279.4157 f: 866.770.5585 Exhibit B- Approved Changes