Loading...
HomeMy WebLinkAbout1411 Crystal Lake Rd-Civil Grading-Drainage Plan 2021-12-15>> DS DSDSDS DS DS DS DS DSDS DS DS 1 . 2 9 % D DS 1 . 2 5 % 1 . 4 4 % 1 . 4 9 % 1 . 4 9 % 3 . 4 9 % 0 . 8 3 % 1 . 0 7 % 0+00 0+50 0+70 1 5 . 0 0 ' TOP OF S L O P E DEFINE D B Y GARY B E A C H E N V I R 0 M E N T A L & CITY OF A S P E N E N G I N E E R I N G DEPART M E N T FIELD L O C A T E D SEPTEM B E R 2 0 , 2 0 1 6 1 5 . 0 0 ' TOP OF SLOP E 15.0' SETBAC K L I N E MEAN HIGH WATER LINE DEFINED BY GARY BEACH ENVIR0MENTAL FIELD LOCATED JULY 21, 2016 (EDGE OF SLOPE ANALYSIS)WETLANDS DELINEATION DEFINED BY GARY BEACH ENVIR0MENTAL FIELD LOCATED JULY 21, 2016 FIRM M A P Z O N E X WITHIN 0 . 2 % A N N U A L C H A N C E F L O O D P L A I N FIRM MAP ZONE A E EXISTING PATIO S F S F SF SF SF SF SF SF SF SF SF SF >> > > 7981 7983 7982 79 8 1 7982 7983 7981 798 0 7 9 8 0 7 9 7 9 7983 7982 7981 7980 7979 7978 EXISTING BOULDER (TYP) EXISTING STORMWATER DRY WELL PROPOSED POOL; RE. TO POOL PLANS BY OTHERS REMOVE EXISTING RETAINING WALL PROPOSED RAIN GARDEN (BRC-1); RE. TO SUMMARY SIZING TABLE & DETAIL SHT. C-2.0 EX. TRENCH DRAIN TO BE PROTECTED OR REPLACED IN KIND IF DAMAGED DURING CONSTRUCTION CONTRACTOR TO SURVEY IN TOP OF SLOPE & INSTALL SILT FENCE (RE. TO DETAIL SHT. C-2.0) TO CONTROL SEDIMENT TRANSPORT & TO ESTABLISH LIMITS OF DISTURBANCE APPROX. LIMITS OF DISTURBANCE (1,550± sf) REPLACE EX. STEPS IN KIND IF DAMAGED DURING CONSTRUCTION 1 1 2 2 3 3 4 4 5 5 EX-BASIN 1; RE. TO BASIN & WQCV SUMMARY TABLE SHT C-2.0 EX-BRC CONTRACTOR TO PROTECT EXISTING RAIN GARDEN AND RE-SHAPE TO ACCOMMODATE FINAL SITE CONDITIONS & ENSURE REQ'D WQCV IS PROVIDE; RE. TO BRC SIZING TABLE SHT. C-2.0 POST-BASIN 1 AREA: 1,000 sf REQ. WQVC: 1411 CRYSTAL LAKE ROAD > >>> EXISTING PATIO PERFORATED UNDERDRAIN W/ CLEANOUTS & SLD. GRATES SOLID UNDERDRAIN W/ RODENT SCREEN INV: 7980.2± FG: 82.25 FL: 82.28 FL: 82.28 TW: 82.50 FL: 82.40FL: 82.40 FL: 82.31 FL: 82.91 FL: 82.00 TC: 83.66 TC: 83.66 TW: 82.50 TW: 82.50 TW: 82.50 TW: 82.50 BW: 81.18 BW: 81.00 BW: 80.72BW: 80.78 BW: 81.04 BW: 80.73BW: 80.85 BW: 81.01 BW: 81.32 SF INSTALL SEDIMENT CONTROL LOG SECTION 1 - 1 7976 7978 7980 7982 7984 7986 7988 7976 7980 7984 7988 0 100-10 SECTION 2 - 2 7976 7978 7980 7982 7984 7986 7988 7976 7980 7984 7988 0 100-10 SECTION 3 - 3 7974 7976 7978 7980 7982 7984 7986 7988 7974 7976 7980 7984 7988 0 100-10 SECTION 4 - 4 7976 7978 7980 7982 7984 7986 7988 7976 7980 7984 7988 0 100-10 SECTION 5 - 5 7976 7978 7980 7982 7984 7986 7988 7976 7980 7984 7988 00-10 15 ' - T O S S E T B A C K 15 ' - T O S SE T B A C K PROPOSED POOL EX. PATIO PROPOSED POOL EX. PATIOTC: 7983.66 TW: 7982.50 TC: 7983.66 FL: 7982.32 TC: 7983.66 FG: 7982.25 TC: 7983.66 FL: 7982.29 TC: 7983.66 FL: 7982.40 TW: 7982.53 TW: 7982.50 TW: 7982.50 TW: 7982.50 EX. TRENCH DRAIN TO BE PROTECTED OR REPLACED IN KIND IF DAMAGED DURING CONSTRUCTION (TYP) BW: 7981.12 15 ' - T O S S E T B A C K 15 ' - T O S S E T B A C K 15 ' - T O S S E T B A C K 15 ' - T O S S E T B A C K BW: 7981.01 BW: 7980.72 BW: 7980.95SURVEY TOP OF SLOPE SETBACK AND INSTALL SILT FENCE FOR SEDIMENT CONTROL & TO DELINEATE LIMITS OF ALLOWABLE DISTURBANCE (TYP) PROPOSED POOL SECTION SCALE HORZ: 1" =5' VERT: 1"=5' SECTION SCALE HORZ: 1" =5' VERT: 1"=5' SECTION SCALE HORZ: 1" =5' VERT: 1"=5' SECTION SCALE HORZ: 1" =5' VERT: 1"=5' SECTION SCALE HORZ: 1" =5' VERT: 1"=5' PROPOSED POOL EX. PLANTER EX. PATIOPROPOSED POOL 6" MAX. OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 31228.01JOB NO. DATE:12-15-2021 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 DATE REVISION C-1.0 DRAWING NO. TITLE G: \ 2 0 2 1 \ 3 1 2 2 8 - 1 4 1 1 C R Y S T A L L A K E R D \ C I V I L \ C I V I L D W G S \ D E \ 3 1 2 2 8 - D E . D W G - D e c 1 5 , 2 0 2 1 - 5 : 0 7 p m N O R T H GRADING, WATER QUALITY & EROSION CONTROL PLAN 14 1 1 C R Y S T A L L A K E R O A D CI T Y O F A S P E N , C O L O R A D O PE R M I T 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 010 10 20 10 405 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R GENERAL NOTES: 1.EXISTING CONTOURS ILLUSTRATED HEREIN ARE AT 1 FT INTERVALS & PREPARED BY SOPRIS ENGINEERING. 2.PROPOSED CONTOURS ARE AT 1 FT INTERVALS. 3.ALL SPOT ELEVATIONS AND GRADING CONCEPTS SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ANY DEVIATIONS SHALL BE COORDINATED WITH THE ENGINEER OF RECORD AND LANDSCAPE ARCHITECT. 4.THIS PROPERTY IS SITUATED IN ZONE "X" (AREA DETERMINED TO BE OUTSIDE THE 500-YEAR FLOOD PLAIN) AS SHOWN ON THE FLOOD INSURANCE RATE MAP PREPARED BY F.E.M.A. FOR PITKIN COUNTY COLORADO, COMMUNITY-PANEL NUMBER 08097C0366E, EFFECTIVE DATE: AUG. 15, 2019. 5.THE CONTRACTOR MUST IMPLEMENT BEST MANAGEMENT PRACTICES (BMP's) TO MINIMIZE THE TRANSPORTATION OF SEDIMENT BEYOND THE LIMITS OF DISTURBANCE. 6.NO SITE DISTURBANCE IS PERMITTED WITHIN THE 15-FT TOP OF SLOPE SETBACK. CONTRACTOR IS REQUIRED TO CONTAIN ALL WORK OUTSIDE THE TOP OF SLOPE SETBACK. 7.CONTRACTOR SHALL PROTECT ALL EXISTING TREES THAT ARE TO REMAIN. A TREE PROTECTION PLAN MUST BE APPROVED BY CITY PARKS DEPARTMENT AND LANDSCAPE ARCHITECT PRIOR TO COMMENCING CONSTRUCTION. 8.THE UTILITIES AS SHOWN, MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION. DRAINAGE DIRECTION/SLOPE SPOT ELEVATION EXAMPLE: FINAL GRADE @ 8001.60' = BW = BOTTOM OF WALL FG = FINISHED GRADE FL = FLOW LINE ME = MATCH EXISTING TW = TOP OF WALL XX:XX.XX' 2.0% FG:01.60' SPOT ELEVATION LEGEND VICINITY MAP SCALE: 1" = 200' PROPOSED CONTOUR PROPOSED CONTOUR INTERVAL7900 EXISTING MINOR CONTOUR (1' INTERVAL) EXISTING MAJOR CONTOUR (5' INTERVAL)8005 PROPOSED SEDIMENT CONTROL LOGSCL PROPOSED LIMIT OF DISTURBANCELOD 8000 LEGEND TITLE PROPERTY DESCRIPTION PARCEL I A parcel of land situated in the NE 1/4 of Section 18, Township 10 South, Range 84 West, of the 6th Principal Meridian, Pitkin County, Colorado and lying entirely within the Riverside Placer MS 3905 AM and being more fully described as follows: Beginning at a point on the Southerly bank of the Roaring Fork River, said point also being on Line 8-9 of said RiversidePlacer, whence corner 9 of said Riverside Placer bears South 242.86 feet; thence North 249.19 feet along said line 8-9; thence East 125.00 feet; thence S 28°30'00" E 132.58 feet; thence S 15°13'00" W 137.22 feet to a point on the centerline of said Roaring Fork River; thence West 2.54 feet along said centerline; thence S 89°53'46" W 149.71 feet to the point of beginning. 30 MIL GEOMEMBRANE LINER BOLTED TO EXISTING CONCRETE STEMWALL OR BY PRE-APPROVED FASTENING METHOD FILTER FABRIC; RE. TO TABLE A FOR SPECIFICATIONS 8" MIN CDOT #3 OR #4 AGGREGATE OR APPROVED EQUAL BRC LANDSCAPING; RE. TO LANDSCAPE PLANS PROPOSED POOL DECK, BY OTHERS. RE: POOL DRAWINGS 2-FT TALL MAX. LANDSCAPE BOULDER CONTAINMENT WALL, TYP. BRIDGE BOULDER WALL OVER DRAIN PIPE; RE. TO DETAIL THIS SHT. 4" PERFORATED RIGID PVC UNDERDRAIN @ 0.5% SLOPE . CONTECH A200 OR APPROVED EQUAL. TRANSITION TO SOLID PIPE PRIOR TO EXITING LINED BASIN. INSTALL RODENT SCREEN AT OUTFALL 4" PVC UNDERDRAIN TO DAYLIGHT TO SURFACE ABOVE TOP OF SLOPE SETBACK LINE. INSTALL RODENT SCREEN AT OUTFALL EXISTING LAWN, TYP. BRC FINISHED GRADE. SEE PLAN VIEW 18" GROW MEDIA; RE. TO SPEC THIS SHT. GEOMEMBRANE LINER; RE. TO TABLE B FOR SPECIFICATIONS OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 31228.01JOB NO. DATE:12-15-2021 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 DATE REVISION C-2.0 DRAWING NO. TITLE G: \ 2 0 2 1 \ 3 1 2 2 8 - 1 4 1 1 C R Y S T A L L A K E R D \ C I V I L \ C I V I L D W G S \ D E \ 3 1 2 2 8 - D E . D W G - D e c 1 5 , 2 0 2 1 - 5 : 1 0 p m DETAILS 14 1 1 C R Y S T A L L A K E R O A D CI T Y O F A S P E N , C O L O R A D O PE R M I T MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R TABLE A: GEOTEXTILE SEPARATOR FABRIC SEPCIFICATIONS RAIN GARDEN (BIO-RETENTION CELL) NOTES: 1.RAIN GARDENS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 8.5.3 OF THE CITY'S URBAN RUNOFF MANAGEMENT PLAN. 2.BIORETENTION GROW MEDIA SPECIFICATIONS (BY VOL.) ·PROVIDE, AS A MINIMUM, 18-INCH LAYER OF WELL MIXED SAND AND SOIL (70% SAND AND 30% COMBINATION OF TOPSOIL AND LARGE ORGANIC MATTER BY VOLUME WITH LESS THAN 5% OF THE MIXED MEDIA PASSING THE 200 SEIVE). ·THE MEDIA MUST INFILTRATE AT LEAST 2IN/HR ·MAINTAIN TOP SURFACE FLAT ·MEDIA SHALL BE DELIVERED FULLY MIXED IN A DRUM MIXER UNLESS ONSITE MIXING MEANS AND METHODS ARE APPROVED BY CITY ENGINEERING. ·MAINTAIN MAX. 3:1 SIDE SLOPES OR INSTALL SMALL BOULDERS/WALLS. ·GEOTECH SHALL CONFIRM PERMEABILITY OF EXISTING SUB GRADE TO CONFIRM WHETHER AN UNDERDRAIN IS REQUIRED. ·THE GROW MEDIA SHALL BE MOISTENED & LEVELED WITH LITTLE OR NO COMPACTION. 3.WRAP ALL SEPARATOR FABRIC TO TOE OF SOIL, ATTACHED FIRMLY TO TRENCH SIDES. (SEE TABLE FOR SPECIFICATIONS) 4.CONTRACTOR SHALL REMOVE EXISTING TOPSOIL AND UNDERLYING SOILS AND REPLACE WITH GROW MEDIA AND FILTER MATERIAL AS ILLUSTRATED. 5.REMOVE & STOCKPILE TOPSOIL, SCARIFY BOTTOM OF EXCAVATION PRIOR TO PLACING SEPARATOR FABRIC. 6.CONTRACTOR TO PROTECT WATER QUALITY BASINS FROM SEDIMENT CONTAMINATION DURING CONSTRUCTION ACTIVITY. SCALE: N.T.S. BRC-1 TYPICAL DETAIL CLASS C FILTER MATERIAL SPECIFICATIONS NOTES: 1.GEOMEMBRANE LINER ONLY REQUIRED WHEN AN UNDERDRAIN IS REQUIRED FOR BIORETENTION CELLS. 2.INSTALL GEOMEMBRANE LINER FOR ENTIRE BIO-RETENTION CELL AREA AND ATTACH TO CONCRETE AS ILLUSTRATED TO ESTABLISH A COMPLETELY LINED BIO-RETENTION CELL. 3.PROVIDE SLACK IN LINER PLACEMENT TO ENSURE PROPER INSTALLATION AND BACKFILL WITHOUT DAMAGE. 4.CORNER SEAMS TO BE WELDED IN FIELD 5.BACKFILL AND UNDERDRAIN SYSTEM NOT SHOWN; RE. TYPICAL BIO-RETENTION CELL SECTION DETAIL BUTYL TAC TAPE 1 4" x 2" STAINLESS STEEL OR GALVANIZED STEEL BATTEN BAR OR PRE-APPROVED EQUAL 3/8" x 3" STAINLESS STEEL ANCHOR BOLT, NUT & WASHER AT 12" O.C. 30 MIL (MIN.) PVC GEOMEMBRANE; EXTEND LINER UP SIDE WALLS A MAX. OF 12-INCHES FROM BOTTOM ENSURING THAT NO PORTION OF LINER OR BATTEN BAR IS EXPOSED AFTER PLACING FILTER MATERIAL AND DECORATIVE AGGREGATE POOL WALL TOP OF GROW MEDIA SCALE: N.T.S. GEOMEMBRANE LINER TO CONCRETE CONNECTION DETAIL 6" MAX. (1 2 " MI N . ) 2' TO 3' 1/2H (12" MIN) FABRIC MATERIAL (ANCHORED IN TRENCH) H SILT FENCE INSTALLATION -NTS- 4" 4" 1/ 2 H H (MAXI M U M ) -NTS- FLOW BACKFILL TRENCH JURISDICTION NOTE: POST ANCHORED TO 15' SECTION COMPACTED 4"x4" OR AS DIRECTED BY LOCAL LANDSCAPING IS COMPLETED, SHALL BE MAINTAINED UNTIL EROSION CONTROL MEASURES SF SILT FENCE DETAIL FERNCO CLAMP OR APPROVED EQUAL EXAMPLE OF AN ANGLED PIPE BOOT ON A SLOPE TABLE B: GEOMEMBRANE LINER SPECIFICATIONS BRC SUMARY TABLEBOND PIPE BOOT SKIRT TO GEOMEMBRANE LINER PER MANUFACTURER'S RECOMMENDATIONS PREFABRICATED OR FIELD FABRICATED PIPE BOOT EXTEND BOOT SUFFICIENT TO INSTALL CLAMPS SOLID GASKETTED SDR-35 UNDERDRAIN PIPE PERFORATED UNDERDRAIN PIPE SEDIMENT CONTROL LOG INSTALLATION NOTES SEDIMENT CONTROL LOG MAINTENANCE NOTES A A SECTION A - A USE TWO STAKES 1 1/2 ' x 1 1/2 " x SUFFICIENT LENGTH TO EMBED AT LEAST 12" INTO SOIL AT EACH END OF LOG USE A STAKE EVERY 24" AT ALTERNATE 90 DEGREE ORIENTATION THROUGHOUT THE SEDIMENTATION LOG. SEDIMENTATION LOG - 12" MIN. DIAMETER STAKE AT 90 DEG. TO EACH OTHER WETLANDS OR FEATURES REQUIRING PROTECTION (NOT TO SCALE) 1.SEE PLAN VIEW FOR: LOCATION OF SEDIMENT CONTROL LOG. 2.SEDIMENT CONTROL LOGS SHALL BE INSTALLED PRIOR TO ANY LAND DISTURBING ACTIVITIES. 3.SEDIMENT CONTROL LOGS SHALL CONSIST OF STRAW, COMPOST, EXCELSIOR OR COCONUT FIBER. 4.NOT FOR USE IN CONCENTRATED FLOW AREAS. 5.THE SEDIMENT CONTROL LOGS SHALL BE TRENCHED INTO THE GROUND A MINIMUM OF 2-INCHES. 1.THE SWMP MANAGER SHALL INSPECT SEDIMENT CONTROL LOGS DAILY, DURING AND AFTER ANY STORM EVENT & MAKE REPAIRS OR CLEANOUT UPSTREAM SEDIMENT AS NECESSARY. 2.SEDIMENT ACCUMULATED UPSTREAM OF SEDIMENT CONTROL LOGS SHALL BE REMOVED WHEN THE UPSTREAM DEPTH IS WITHIN 1 2 THE HEIGHT OF THE CREST OF LOG. 3.SEDIMENT CONTROL LOGS SHALL BE REMOVED AT THE END OF CONSTRUCTION, ONCE PROPER VEGETATION HAS BEEN ESTABLISHED. IF ANY DISTURBED AREA EXISTS AFTER REMOVAL IT SHALL BE COVERED WITH TOPSOIL AND REVEGETATED/STABILIZED IN A MANNER APPROVED BY THE LOCAL JURISDICTION. SEDIMENT CONTROL LOG SCALE: N.T.S. GEOMEMBRANE LINER PIPE PENETRATION DETAIL SCH. 80 SOLID DRAIN PIPE W/ RODENT SCREEN AT OUTFALL 8" MIN. BRIDGE BOULDERS OVER STORM PIPE TO PREVENT CRUSHING. DO NOT PLACE BOULDERS DIRECTLY ON TOP OF PIPE. PIPE BEDDING FINISHED GRADE SCALE: N.T.S. BOULDER WALL BRIDGE DETAIL