Loading...
HomeMy WebLinkAboutAppendix B. Detailed Review Plan SetLANDSCAPE ARCHITECT: DESIGNWORKSHOP CONTACT: Richard Shaw 120 East Main Street Aspen, Colorado 81611 Tel: (970) 925-8354 GORSUCH HAUS SUBDIVISION/ DETAIL REVIEW PLAN SET COVER SHEET N CIVIL ENGINEER: SOPRIS ENGINEERING CONTACT: Jesse Swan Main Street Carbondale, CO 81623 Tel: (970) 7040311 DW PROJECT NUMBER 4735 South Aspen Street GORSUCH HAUS ASPEN, COLORADO VICINITY MAP PROJECT DESCRIPTION LODGE AND LIFT ONE CORRIDOR Sheet No. Sheet Title P001 Draft Gorsuch Haus Subdivision/Detail Review Plan Set Cover Sheet P002 Site Improvement Survey P003 Proposed Illustrative Site Plan P004.1 Existing and Proposed Development Overlay P004.2 Proposed Development Enlargements P004.3 Proposed Development Enlargements P005 Existing Landscape Plan P006 Proposed Landscape Plan P007 Public Amenities Plan P008 Illustrative Perspective P009 Illustrative Perspective World Cup P010 Illustrative Plan arrival at South Aspen St. P011 Illustrative Perspective South Apsen St. Approach R100 Reference Plan - Level P1 R101 Reference Plan - Level 01 R102 Reference Plan - Level 02 R103 Reference Plan - Level 03 R104 Reference Plan - Level 04 R105 Reference Plan - Level 05 R106 Reference Plan - Level 06 R107 Reference Plan - Level 07 R108 Reference Plan - Level 08 R109 Reference Plan - Level 09 R110 Reference Plan - Roof G031 Proposed Floor Area Calculations G032 Proposed Floor Area Calculations G033 Proposed Floor Area Calculations G034 Height Plan - Proposed Grade D200 Building Elevations D201 Building Elevations G050 Snow Shedding Roof Plan G051 Dormer Plan A801 Material Board C.1.00 Cover & General Notes C.1.01 Overall Site Plan C.1.02 Snow Storage Plan C.1.03 Emergency Fire Staging Plan C.2.00 Cul-de-sac Plan, Profile and Grading C.2.01 Cul-de-sac Sections C.2.02 Cul-de-sac Sidewalk Plan & Profiles C.2.03 Conceptual Perimeter Grading Plan C.2.04 Mountain Road Plan, Profile & Grading C.2.05 Mountain Road Sections C.2.06 West Swale Plan, Profile & Sections C.2.07 Mudflow Mitigation Plan C.3.00 Master Conceptual Utility Plan C.3.01 Ruthie's Sanitary Sewer Service Plan & Profile C.3.02 Gorsuch Haus Sanitary Sewer Service Plan & Profile C.3.03 16" Water Main Plan & Profile STA: 0+00+2+50 C.3.04 16" Water Main Plan & Profile STA: 2+50+END C.3.05 6" Water Service Plan & Profile C.4.00 Existing Offsite Drainage Basin Plan C.4.01 Post Development Drainage Basin Plan C.4.02 Conceptual Master Drainage Plan C.4.03 Onsite Conceptual Water Quality Treatment Plan C.4.04 West Storm Pipe Profile C.4.05 East Storm Pipe Profile C.4.06 East Storm Pipe Profile C.5.00 Site Details C.5.01 Sanitary Sewer Details (Typ.) C.5.02 City of Aspen Water Details S.101 Gorsuch Haus PD/ Subdivision S.102 Gorsuch Haus PD/ Subdivision S.103 Gorsuch Haus PD/ Subdivision S.104 Gorsuch Haus PD/ Subdivision S.201 Street and Easement Vacation Plat SHEET INDEX ARCHITECT: 4240 CONTACT: Christian Barlock 3507 Ringsby Court Suite 117 Denver, CO 80216 Tel: (303) 292-3388 MEP. ENGINEER: BG BUILDING WORKS CONTACT: 222 Chapel Place, Unit AC-201 P.O. Box 9650, Avon, CO 81620 Tel: (970) 949-6108 PROJECT MANAGER: NORWAY ISLAND LLC. CONTACT: Jean Coulter Tel: (303) 882-0702 DEAN S T R E E T MO N A R C H S T R E E T SO U T H A S P E N S T R E E T PROJECT SITE Project is located in downtown Aspen,Colorado. Together with the Lift One Corridor, the Gorsuch Haus and infrastructure, skiing, and public amenity improvements comprise significant development at the western portal to Aspen Mountain. Issue Date: March 2, 2020 3- 0 2 - 2 0 2 0 DR A F T R E V I E W P L A N S E T LIGHTING DESIGNER: 186 LIGHTING DESIGN GROUP CONTACT: Greg Mackell 1200 Bannock St, Denver, CO 80204 Tel: (303) 534-5350 ASPE N M O U N T A I N GON D O L A Detail Application Drawings: NTS Appendix B. XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XELXEL XU T XU T XU T XU T x x X S D X S D X S D XE L XEL XE L XEL XEL XEL XEL XEL XEL XUT X U T XUT XU T XG A S XU T XU T XU T X U T XU T XUT XUT XU T XEL XEL XEL XEL XEL XEL X E L XE L XE L XE L XEL XEL XE L X E L XEL XEL XEL XE L XE L XE L XE L XE L XE L XE L XE L XE L XE L XE L XE L X E L X E L XE L XEL XEL XEL XEL XE L XE L XE L XE L XE L X E L X E L XE L XE L XE L XE L XE L XE L X U T X U T XU T XU T X U T XU T XU T XU T XU T XU T X U T XU T XU T XU T XGAS XGAS XGAS XGAS XGAS XGAS X G A S XWL XWL XWL XWL XWL XWL XWL X W L XW L XW L XU T XU T XU T XU T XU T XU T XU T XU T XUT XUT XUT XUT XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T X U T XEL XSA XS A XSA XSA XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XTVXUT XTV X U T XE L XE L XE L XE L XE L XE L X T V XS D XS D XS D XS A XS A XS A XW L XGA S XGAS X G A S X G A S XG A S XG A S XG A S XG A S XG A S X G A S XG A S XG A S XG A S XE T C XE T C X S D X S D XSD X W L X W L X W L X W L XW L XW L XTV > > > S. ASPEN STREET 75.3' WIDE R.O.W. SUMMIT S T R E E T 20.0' WID E R . O . W . HILL STRE E T25.0' WID E R . O . W . FOUND #5 REBAR AND 114" PLASTIC CAP L.S. #25947 CENTERLINE 15' WIDE WATER PIPELINE EASEMENT GRANTED TO CITY OF ASPEN BK.412 PG.557 S 69°30'00" E 36.50' S 64° 2 5 ' 0 0 " E 3 1 . 0 0 ' S 2 1 ° 2 2 ' 0 0 " W 4 8 . 5 0 ' 7.5 ' 53.26' 27.52' EASEM E N T G R A N T E D B Y MOUN T A I N Q U E E N C O N D O S FOR SK I E R S A N D P E D E S T R I A N S PLAT B K . 4 P G . 4 8 9 AND W A T E R L I N E E A S E M E N T T O C I T Y O F A S P E N BK. 41 1 P G . 9 9 6 90' WIDE SKI EASEMENT CENTERED OVER EXISTING LIFT 1A BK.259 PG.83 CENTERLINE 15' WIDE DRAINAGE EASEMENT GRANTED TO MOUNTAIN QUEEN CONDOS BK.291 PG.649 7.5 ' S 32°25'30" E 16.87' S 1 0 ° 2 5 ' 3 0 " E 7 7 . 7 0 ' N 79°34'30" E 4.50' NE14 NE14 SECTION 13 SE14 NE14 SECTION 13 PARCEL 4 240,375 sq.ft.± 5.518 acres± (PORTION OF LOT 31, SECTION 13 WITHIN CITY LIMITS) SOUTHERLY BOUNDARY LINE OF SOUTH ASPEN STREET R.O.W. PER BARBEE SUBDIVISION RECREATION EASEMENTREC. #597440 (PARA. 2) SKI CORRIDOR EA S E M E N T REC. #597440 45.0' AREA OF REVOKABLE ENCROACHMENT LICENSE GRANTED TO SHADOW MOUNTAIN VILLAGE APARTMENTS REC. #543674 ASPEN C I T Y L I M I T S PITKIN C O U N T Y S. ASPEN STREET 37.65' WIDE R.O.W. PARCEL 2 10,917 sq.ft. 0.251 acres± PARCEL 1 23,897 sq.ft.± 0.549 acres± PARCEL 3 2,973 sq.ft.± 0.068 acres± LIFT TOWERS (TYP) GRAVEL ROAD STORMGRATE LIFT LOADAREA SH E D ST E P S SH E D GR O U N D L E V E L DE C K TRAILER LIFT 1A TERMINAL BUILDING TWO-STORYWOOD FRAME CONSTRUCTION PARKINGAREA (ASPHALT) RAILROAD TIERETAINING WALL (TYP)ST E P S GRAVELSURFACE GATE CONTROLLER ELECTRONIC GATE RETAINI N G W A L L ST E P S POOL POOL SKI TRAIL AREA OF DENSE VEGETATION AREA OF DENSEVEGETATION 4"X4" POST 50' SETBACKBUILDING RESTRICTION BK 231 PG 278 37.65' EDGE OF VEGETATION SNOWMAKING HYDRANT &FAN GUN ELECTRIC PEDESTAL A P P R O X I M A T E S T R A I G H T L I N E D B E T W E E N F I E L D L O C A T E D M A N H O L E S GAS RISER ELECTRIC SWITCHGEAR ELECTRIC METER CABINET ELECTRIC TRANSFORMER ELECTRICTRANSFORMER (PLACED FROM CITY OF ASPEN GIS AERIAL) SNOWMAKING HYDRANT &FAN GUN ELECTRIC PEDESTAL SNOWMAKING HYDRANT &FAN GUN ELECTRIC PEDESTAL 39 40 41 42 43 44 45 20.0' WIDE EASEMENT FOR FIRE ACCESS AND DRAINAGE GRANTED TOMOUNTAIN QUEEN CONDOSBK.275 PG.378 AND WATERLINE EASEMENT GRANTED TO CITY OF ASPENBK.291 PG.649 13139.01 01/02/2020 CL G:\2013\13139\SURVEY\Survey DWGs\13139-ISP.dwg CIVIL CONSULTANTS 502 MAIN STREET, SUITE A3 CARBONDALE, COLORADO 81623 (970) 704-0311 NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGALACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TENYEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. A PARCEL OF LAND SITUATED IN THE NE14NE14 AND SE14NE14 OF SECTION 13 TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE 6th P.M. CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADOSHEET 3 OF 4 SUBJECT PROPERTY EXISTING CONDITIONS IMPROVEMENT SURVEY PLAT OF: EXISTING GAS EXISTING COMMON TRENCH EXISTING UNDERGROUND ELECTRIC EXISTING OVERHEAD ELECTRIC EXISTING WATER EXISTING SEWER EXISTING UNDERGROUND TELEPHONE EXISTING SIGN EXISTING SEWER CLEANOUT EXISTING TELEPHONE SERVICE EXISTING LIGHT POLE EXISTING GAS METER EXISTING TELEPHONE MANHOLE EXISTING UTILITY MANHOLE EXISTING POWER POLE EXISTING ELECTRIC SERVICE EXISTING WATER MANHOLE EXISTING GUY WIRE EXISTING SEWER MANHOLE EXISTING ELECTRIC MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING DRAINAGE MANHOLE EXISTING ELECTRIC TRANSFORMER EXISTING CONDITIONS LEGEND EXISTING BUSH EXISTING EDGE OF VEGETATION EXISTING CONIFER TREE - CALIPER"XDRIP DIAMETER' EXISTING DECIDUOUS TREE - CALIPER"XDRIP DIAMETER' EXISTING BOULDER EXISTING WIRE FENCE EXISTING WOOD FENCE EXISTING CHAIN LINK FENCE EXISTING ROCK RETAINING WALL EXISTING TIE RETAINING WALL EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING GAS MARKER EXISTING IRRIGATION VALVE BOX EXISTING IRRIGATION VALVE BOX 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 030 30 60 30 12015TREE DISCLAIMER SOPRIS ENGINEERING PERSONNEL ARE NOT TRAINED ARBORISTS OR LANDSCAPE PROFESSIONALS. THE TREE INFORMATION SHOWN HEREON WAS FIELD SURVEYED BY SOPRIS ENGINEERING TO THE BEST OF OUR ABILITY AS PART OF THE PROJECT'S SCOPE. DATA WAS ACQUIRED PER PROCEDURES OUTLINED IN THE CITY OF ASPEN ENGINEERING DEPARTMENT'S SUBMITTAL CHECKLIST. CURRENT CITY OF ASPEN RIGHT-OF-WAY AREASPROPOSED TO BE VACATED AREA OF REVOKABLE ENCROACHMENT LICENSE GRANTED TO SHADOW MOUNTAIN VILLAGE APARTMENTS REC. #543674 SEE DETAIL THIS SHEET FORADDITIONAL VEGETATION INFORMATION 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 010 10 10 5 ADDITIONAL VEGETATION DETAIL VEGETATION TYPE AND DIMENSIONS OEL OEL XUT XUT XEL XEL XSA XSA XWL XWL XGAS XGAS XETC XETC EXISTING STORM SEWERXSDXSD TREENUMBER TREE TYPE TRUNKDIAMETER (INCHES) DRIPLINEDIAMETER (FEET) 1 SUB 3" GROUP 4 2 GAMBLE OAK 5 10 3 SUB 3" GROUP 6 4 GAMBLE OAK 4 8 5 GAMBLE OAK 4 8 6 GAMBLE OAK 4.6 8 7 GAMBLE OAK 4.8 8 8 SUB 3" GROUP 4 9 SUB "3 GROUP 4 10 GAMBLE OAK 4.1 8 11 SUB 3" GROUP 2 12 SUB 3" GROUP 2 13 SUB 3" GROUP 8 14 CHOKE CHERRY 3.6 7 15 CHOKE CHERRY 3.1 6 16 CHOKE CHERRY 3 6 17 SUB 3" GROUP 5 18 SUB 3" GROUP 5 19 CHOKE CHERRY 3.2 6 20 CHOKE CHERRY 3 6 21 CHOKE CHERRY 3 6 22 CHOKE CHERRY 4.3 8 23 CHOKE CHERRY 5.3 10 24 SUB 3" GROUP 4 25 CHOKE CHERRY 4.7 10 26 SUB 3" GROUP 5 27 SUB 3" GROUP 7 28 SUB 3" GROUP 6 29 SUB 3" GROUP 6 30 SUB 3" GROUP 4 31 CHOKE CHERRY 3.4 6 32 SUB 3" GROUP 3 33 CHOKE CHERRY 3.1 6 34 CHOKE CHERRY 3.1 6 35 CHOKE CHERRY 3.1 6 36 DECIDUOUS TREE 5.8 12 37 DECIDUOUS TREE 3.6 6 38 PINE TREE 4 8 39 PINE TREE 7.3 14 40 PINE TREE 14.6 28 41 PINE TREE 12 24 42 PINE TREE 17 34 43 PINE TREE 13 26 44 DECIDUOUS TREE 37 65 45 PINE TREE 9.2 18 46 PINE TREE 10.8 22 47 DECIDUOUS TREE 13.5 26 48 DECIDUOUS TREE 30.1 60 49 DECIDUOUS TREE 40.2 70 50 DECIDUOUS TREE 3.5 7 51 DECIDUOUS TREE 4.2 8 ______________________________________ MARK S. BECKLER L.S. #28643 P002 LIFT ONE LODGE FOOTPRINT* LIFT ONE LODGE FOOTPRINT* SO U T H A S P E N S T R E E T SHADOW MOUNTAIN CONDOMINIUMS MOUNTAIN QUEEN CONDOMINIUMS M O U N T A I N O P E R A T I O N S R O A D CARIBOU CONDOMINIUMS GORSUCH HAUS NORWAY RUN AN S I S E T B A C K Lift Corridor & Proposed Lift Towers Lodge Loading/ Unloading Schuss Gully Ski Run Outdoor Restaurant/ Apres Ski Deck Indoor Restaurant & Bar Relocated Mountain Access Road Expanded South Aspen St. Culd-de-Sac Pedestrian Access Path New Pedestrian Pathway Gorsuch Haus Lodge: • 81 Hotel Lodging Rooms • 4 Free-Market Multi-Family Units • 1 Affordable Housing Unit • Underground Structured Parking: 56 Spaces *Approximate Location Based on Ordinance 38 Series of 2018 1 2 3 4 5 6 7 8 9 9 1 6 4 5 2 3 8 7 S W I T C H G E A R LIFT 1 LODGE *2019 PROPOSED FOOTPRINT 0 ORIGINAL SCALE: 10 20 40 1"= 20' KEY PLAN NOT TO SCALE NORTH C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS 4735 GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED W W W . D E S I G N W O R K S H O P . C O M DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 EXISTING AND PROPOSED DEVELOPMENT OVERLAY P004.1 OVERALL SITE PLAN SCALE: 1”-30’ S W I T C H G E A R LIFT 1 LODGE *2019 PROPOSED FOOTPRINT 1.2 KEY PLAN NOT TO SCALE C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS 4735 GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED W W W . D E S I G N W O R K S H O P . C O M DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 P004.2 SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8 WALL MATERIAL LEGEND: A STONE VENEER WALL - SEE ARCHITECTURE MATERIALS LEGEND B CONCRETE WALL - SEE ARCHITECTURE MATERIALS LEGEND *NOTE: DEPENDING ON WEST STAIR, IT MAY ONLY BE STONE. PROPOSED DEVELOPMENT ENLARGEMENTS S W I T C H G E A R DS DS DS DS DS DS LE V E L 2 A B O V E LE V E L 3 A B O V E BUILDING SUBGRADE LIFT CENTER LINE LIFT CABLE GAUGE EDGE OF CARRIER LI M I T O F P R O J E C T S C O P E O F W O R K LIFT ONE PARK RO O F A B O V E TOWER 4 0 ORIGINAL SCALE: 5 10 20 1"= 10' KEY PLAN NOT TO SCALE TYP. 1.4a 1.4b 1.5a 1.5b TYP. 1.6TYP. TYP. TYP. TYP. 3.1a 4.1b 4.1a 3.2b 4.1a 10.8 10.8 10.16.1 10.2 10.3 10.4 8.2 TYP. 10.8 10.7TYP. 6.1 6.1 1.2 5.3 5.1 TYP. NORTH 8.4 5.5 TYP. LEVEL 1 SITE PLAN C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 4735 2 3 4 5 6 7 A B C D E GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED F 8 9 1 2 3 4 5 6 7 8 9 W W W . D E S I G N W O R K S H O P . C O M M a r 0 1 , 2 0 2 0 - 4 : 4 7 p m F: \ P R O J E C T S _ A - L \ 4 7 3 5 - L i f t 1 a \ D - C A D \ 0 2 . S h e e t s \ D W - 4 7 3 5 - E X . C - D e t a i l e d S i t e P l a n . d w g DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 4.2 TYP. 1.5b TYP. SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8 A B A A 1.3a S W I T C H G E A R PROPERTY BOUNDARY SETBACK LEVEL 2 LIMIT OF PROJECT SCOPE OF WORK LE V E L 2 B A L C O N Y LE V E L 3 A B O V E LIFT CENTER LINE LIFT CABLE GAUGE EDGE OF CARRIER LIMIT OF WORK HILL STREET ROW TOWER 4 LEVEL 2 LIMIT OF PROJECT SCOPE OF WORK LE V E L 2 B A L C O N Y 1.1 4.1a 1.3a 1.3a 1.4b TYP.TYP. 5.2TYP. TYP. 6.3 6.3 6.4 TYP.4.1b 5.1 6.4 3.2b 6.1 1.3a TYP. 0 ORIGINAL SCALE: 5 10 20 1"= 10' KEY PLAN NOT TO SCALE TYP. NORTH LEVEL 2 SITE PLAN C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 4735 2 3 4 5 6 7 A B C D E GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED F 8 9 1 2 3 4 5 6 7 8 9 W W W . D E S I G N W O R K S H O P . C O M M a r 0 1 , 2 0 2 0 - 5 : 1 5 p m F: \ P R O J E C T S _ A - L \ 4 7 3 5 - L i f t 1 a \ D - C A D \ 0 2 . S h e e t s \ D W - 4 7 3 5 - E X . C - D e t a i l e d S i t e P l a n . d w g DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 6.1 6.1 3.1a 1.3a 4.2 TYP. TYP. SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8 TYP. B A A S W I T C H G E A R RO O F A B O V E TYP. 3.2b 6.1 6.1 TYP. 1.4b 10.6 5.1 TYP. 0 ORIGINAL SCALE: 5 10 20 1"= 10' KEY PLAN NOT TO SCALE NORTH LEVEL 3 SITE PLAN C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 4735 2 3 4 5 6 7 A B C D E GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED F 8 9 1 2 3 4 5 6 7 8 9 W W W . D E S I G N W O R K S H O P . C O M M a r 0 1 , 2 0 2 0 - 5 : 2 2 p m F: \ P R O J E C T S _ A - L \ 4 7 3 5 - L i f t 1 a \ D - C A D \ 0 2 . S h e e t s \ D W - 4 7 3 5 - E X . C - D e t a i l e d S i t e P l a n . d w g DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 LEVEL 3 BALCONY 6.1 1.3a 6.1 3.1aTYP. 1.3b 4.2 SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8 4.1b A B B DS DS DS DS DS DSDS DS DS DS SETBACK PR O P E R T Y B O U N D A R Y SE T B A C K PROPERTY BOUNDARY SETBACK LE V E L 5 F L O O R P L A T E LIFT CENTER LINE LIFT CABLE GAUGE EDGE OF CARRIER LIMIT OF WORK TOWER 5 LEVEL 4 LIMIT OF PROJECT SCOPE OF WORK 4.1b 10.6 1.4b TYP. TYP. 4.1a 1.4a TYP. TYP. 3.2b 6.1 0 ORIGINAL SCALE: 5 10 20 1"= 10' KEY PLAN NOT TO SCALE NORTH LEVEL 4-6 SITE PLAN C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 4735 2 3 4 5 6 7 A B C D E GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED F 8 9 1 2 3 4 5 6 7 8 9 W W W . D E S I G N W O R K S H O P . C O M M a r 0 1 , 2 0 2 0 - 4 : 5 3 p m F: \ P R O J E C T S _ A - L \ 4 7 3 5 - L i f t 1 a \ D - C A D \ 0 2 . S h e e t s \ D W - 4 7 3 5 - E X . C - D e t a i l e d S i t e P l a n . d w g DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 BUILDING OVERHEAD 1.3a 3.1a 6.1 3.1a 4.1a TYP. TYP. TYP. TYP. 4.2 TYP. TYP. SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8 B A A B A A LEVEL 1 ENLARGEMENT SCALE: LEVEL 3 ENLARGEMENT SCALE: LEVEL 2 ENLARGEMENT SCALE: LEVEL 4-6 ENLARGEMENT SCALE: 1”- S W I T C H G E A R LIFT 1 LODGE *2019 PROPOSED FOOTPRINT PROPOSED DEVELOPMENT ENLARGEMENTS KEY PLAN NOT TO SCALE C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS 4735 GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED W W W . D E S I G N W O R K S H O P . C O M DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 P004.3 SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8 WALL MATERIAL LEGEND: A STONE VENEER WALL - SEE ARCHITECTURE MATERIALS LEGEND B CONCRETE WALL - SEE ARCHITECTURE MATERIALS LEGEND *NOTE: DEPENDING ON WEST STAIR, IT MAY ONLY BE STONE. DS DS DS DS DS DSDS DS DS DS SETBACK PR O P E R T Y B O U N D A R Y SE T B A C K PROPERTY BOUNDARY SETBACK LIMIT OF WORK LEVEL 7 LIMIT OF PROJECT SCOPE OF WORK LEVEL 7 LIMIT OF PROJECT SCOPE OF WORK TOWER 5 1.4a TYP. 4.1a TYP. 0 ORIGINAL SCALE: 5 10 20 1"= 10' KEY PLAN NOT TO SCALE NORTH LEVEL 7 SITE PLAN C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 4735 2 3 4 5 6 7 A B C D E GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED F 8 9 1 2 3 4 5 6 7 8 9 W W W . D E S I G N W O R K S H O P . C O M M a r 0 1 , 2 0 2 0 - 4 : 5 4 p m F: \ P R O J E C T S _ A - L \ 4 7 3 5 - L i f t 1 a \ D - C A D \ 0 2 . S h e e t s \ D W - 4 7 3 5 - E X . C - D e t a i l e d S i t e P l a n . d w g DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8 A A SETBACK PR O P E R T Y B O U N D A R Y SE T B A C K PROPERTY BOUNDARY SETBACK LIFT CENTER LINE LIFT CABLE GAUGE EDGE OF CARRIER LIMIT OF WORK LE V E L 8 L I M I T O F P R O J E C T S C O P E O F W O R K TOWER 5 LEVEL 8 SITE PLAN 1.7 10.6 3.3 4.1a TYP. TYP. 0 ORIGINAL SCALE: 5 10 20 1"= 10' KEY PLAN NOT TO SCALE NORTH C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 4735 2 3 4 5 6 7 A B C D E GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED F 8 9 1 2 3 4 5 6 7 8 9 W W W . D E S I G N W O R K S H O P . C O M M a r 0 1 , 2 0 2 0 - 5 : 0 6 p m F: \ P R O J E C T S _ A - L \ 4 7 3 5 - L i f t 1 a \ D - C A D \ 0 2 . S h e e t s \ D W - 4 7 3 5 - E X . C - D e t a i l e d S i t e P l a n . d w g DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 1.4b TYP. SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 2.0 JOINTING 3.0 STEPS 4.0 SITE WALLS/ EMBANKMENTS 5.0 SITE FURNITURE 6.0 RAILINGS, BARRIERS, FENCING 7.0 SITE LIGHTING 8.0 DRAINAGE 9.0 PLANTING AND LANDSCAPE 10.0 MISCELLANEOUS ELEMENTS 5.1 Planter Type 1 1.2 1.3a Concrete Paving Type 1A 1.4a Stone Paving Type 1B - Over Structure Stone Paving Type 1A 1.3b 3.1a Stair Type 1a - Concrete 3.1b Stair Type 1b - Concrete Over Structure 4.1a Wall Type 1a - Stone Veneer 4.1b 5.2 Planter Type 2 - Window Box 5.3 Benches 5.4 Trash Receptacles 5.5 Bike Racks 6.1 Handrail Type 1 6.2 Handrail Type 2 6.4 10.1 6.3 4.2 Wall Type 1b - Stone Veneer Over Structure 5.6 Ski Racks 8.1 Hardscape Area Drain Fire Feature Water Feature Entry Sign REFER TO PLANTING SERIES. 8.3 Trench Drain 8.4 Slot Drain 10.2 Utility Area Overhead Screening Grate 2.1 Control Joint 2.2 Expansion Joint - Doweled 2.3 Expansion Joint - Non-Doweled Stone Paving Type 2A - 4x4 Cobble 1.4b Gravel Paving - Decomposed Granite 1.5a Concrete Paving Type 1B - Over Structure Stone Paving Type 2B - Over Structure1.5b Silva Cells 1.7 2.4 Stone Paving Mortar Joint - Type 1 3.2a Stair Type 2a - Stone Veneer 3.2b Stair Type 2b - Stone Veneer Over Structure 3.3 Stair Type 3 - Stone Veneer - Roof Wall Type 2 Rusticated Ribbed Concrete Wall 10.3 Utility Area Gates 10.4 Art Installation10.5 Mountain Access Road Ramp 1.1 Gravel Mulch Flagpoles 10.6 Stone Paving Type 3 - Stone Band Over Structure1.6 Stone Paving Type 4 - Roof 10.7 4.3 Crafted Boulder Wall 8.2 Softscape Area Drain 2.5 Stone Paving Mortar Joint - Type 2 REFER TO LIGHTING DESIGNER DRAWINGS. Pylon Light10.8A A 3.2a 6.1 1.4a LEVEL 7 ENLARGEMENT SCALE: LEVEL 8 ENLARGEMENT SCALE: 3 0 2 8 2 6 2 7 2 9 1 2 1 1 8 1 0 3 6 3 7 9 3 2 3 1 1 4 1 3 1 8 1 6 1 5 1 7 3 5 3 4 3 3 3 2 4 5 7 2 0 2 5 1 9 2 4 2 1 2 2 2 3 8095 812 0 808 0 80 3 5 803 0 PROPERTY BOUNDARY SETBACK LIMIT OF WORK LIMIT OF WORK 0 ORIGINAL SCALE: 15 30 60 1"= 30' EXISTING LANDSCAPE PLAN SITE KEYNOTES: 11.0 PLANT PROTECTION DETAI SHEE 2 TYP TYP. NORTH 1 TYP 2 TYP. 11.0 3 C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: 1 REVISIONS 4735 2 3 4 5 6 7 A B C D E GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED F 8 9 1 2 3 4 5 6 7 8 9 W W W . D E S I G N W O R K S H O P . C O M F e b 1 2 , 2 0 2 0 - 1 0 : 2 9 a m F: \ P R O J E C T S _ A - L \ 4 7 3 5 - L i f t 1 a \ D - C A D \ 0 2 . S h e e t s \ D W - 4 7 3 5 - E X . D - E x i s t i n g L a n d s c a p e P l a n . d w g DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 SIZE NOTESTREE TYPETREE # TREE REMOVAL LIST 15 16 19 3.1" cal. 3" cal. 3.2" cal. 3" cal. 3" cal. 4.3" cal. 5.3" cal. 4.7" cal. 3.4" cal. 3.1" cal. 3.1" cal. 3.1" cal. 7.3" cal. 14.6" cal. 12" cal. 17" cal. 13" cal. 37" cal. 9.2" cal. 10.8" cal. 13.5" cal. 30.1" cal. 40.2" cal. NOTES: 1.Only Deciduous trees larger than 6" caliper in size, Conifer trees larger than 4" caliper in size, and Gamble Oak/Choke Cherry trees larger than 3" caliper in size, are provided on this chart. Additional vegetation (i.e, understory shrubs, groundcover, etc.) may also need to be removed and is indicated as approximately as possible. Final limits of vegetation removal shall be determined in field. 2.Refer to Sheet L0-04 for Tree Removal Summary Chart. 3.Refer to Plant List for proposed trees and caliper inches for mitigation Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Choke Cherry Pine Tree Pine Tree Pine Tree Pine Tree Pine Tree Deciduous Tree Pine Tree Pine Tree Deciduous Tree Deciduous Tree Deciduous Tree 20 21 22 23 25 31 33 34 35 39 40 41 42 43 44 45 46 47 48 49 NOTE: Only trees planned to be removed are labeled in this list. Find corresponding trees labeled below on drawing. 29 27 31 32 33-3515-17 19-25 30 39-41 42 44 4849 43 47 46 45 1 Existing tree to be preserved. Do not disturb. Protect in place. PLANT PROTECTION & DEMO REFERENCE NOTES: 2 Existing tree to be removed. 3 Existing stand of shrubs to be removed. 1TYP P005OVERALL PROPOSED LANDSCAPE PLAN SCALE: 1”- S W I T C H G E A R DS DS DS DS DS DS DS DS DS DS DS DSDS DS DS DS 80 4 5 80 5 5 80 7 0 80 7 5 80 8 0 TOWER 6 TOWER 7 TOWER 4 3 0 2 8 2 6 2 7 2 9 1 2 1 1 8 1 0 3 6 3 7 9 3 2 3 1 1 4 1 3 1 8 1 6 1 5 1 7 3 5 3 4 3 3 3 2 4 5 7 2 0 2 5 1 9 2 4 2 12 2 2 3 8095 812 0 808 0 80 3 5 803 0 SETBACK PROPERTY BOUNDARY SETBACK LIFT 1 LODGE *2019 PROPOSED FOOTPRINT 0 ORIGINAL SCALE: 10 20 40 1"= 20' PROPOSED LANDSCAPE PLAN KEY PLAN NOT TO SCALE NATIVE G R A S S NATIVE GRASS NATIVE G R A S S WILD FLOWER MIX SOD NORTH PITCO Native Grass Mix Effusa JuniperJuniperus communis 'Effusa' Colorado Blue SprucePicea pungens NATIVE GRASSES/ WILDFLOWERS GROUNDCOVERS/ PERENNIALS/ ORNAMENTAL GRASSES DECIDUOUS & EVERGREEN SHRUBS CONIFEROUS TREES DECIDUOUS TREES Green AshFraxinus americana COMMON NAMEBOTANICAL NAME PLANT LIST Woods' RoseRosa Woodsii Japanese SpireaSpiraea japonica 'Froebelii' McKay's White PotentillaPotentilla fruticosa 'McKay's White' Meadow Sage SalviaSalvia nemorosa 'Caradonna' Peking CotoneasterCotoneaster acutifolius var. lucidus Grow Low SumacRhus aromatica 'Gro-Low' Virginia CreeperParthenocissus quinquefolia VINE Purple ConeflowerEchinacea purpurea Purple ConeflowerEchinacea purpurea 'White Swan' Johnson's Blue GeraniumGeranium 'Johnson's Blue' Alaska Shasta DaisyLeucanthemum x superbum Autumn Joy StonecropSedum spectabile 'Autumn Joy' Faassen's CatmintNepeta x faassenii 'Little Trudy' Rocky Mountain ColumbinAquilegia caerulea Massachusetts KinnikinnicArctostaphylos uva-ursi 'Massachusetts' Mother of ThymeThymus serpylum PITCO Wildflower Mix Kentucky Blue GrassPoa pratensis SOD Colorado Blue SprucePicea pungens Colorado Blue SprucePicea pungens Colorado Blue SprucePicea pungens Cranberry CotoneasterCotoneaster apiculatus False Forget-Me-NotBrunnera macrophylla Ragwort 'The Rocket'Ligularia stenocephala Sweet WoodruffGalium odoratum Red Twig DogwoodCornus sericea Peking CotoneasterCotoneaster acutifolius 2PP-18 6FA-3 3PP-20 1PP-22 4PP-16 QTY.ABBR. PLANTING PLAN REFERENCE NOTES 1 All Areas distributed due to construction activity, shall be re-vegetated with approved native seed mix. 2 Existing Aspen to remain 3 Existing Spruce to remain C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS 4735 GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED W W W . D E S I G N W O R K S H O P . C O M DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 P006 WILDFLOWER MIX NATIVE GRASS MIX OVERALL PROPOSED LANDSCAPE PLAN SCALE: 1”- PUBLIC AMENITIES PLAN 0 ORIGINAL SCALE: 15 30 60 1"= 30" KEY PLAN NOT TO SCALE NORTH C DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS 4735 GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O C O P Y R I G H T D E S I G N W O R K S H O P, I N C. DETAILED W W W . D E S I G N W O R K S H O P . C O M DESIGN WORKSHOP Landscape Architecture · Land Planning Urban Design · Tourism Planning Asheville · Aspen · Austin · Chicago · Denver · Dubai Houston · Lake Tahoe · Los Angeles · Shanghai 120 East Main Street (970) 925-8354 (970) 920-1387 Aspen, Colorado 81611 APPLICATION MM, CK RWS January 15, 2020 PROPOSED PUBLIC AMENITY SPACE LEVEL 3 TOTAL: 2,150 SF LEVEL 4-6 TOTAL: 2,584 SF LEVEL 1 TOTAL: 2,084 SF LEVEL 2 TOTAL: 1,298 SF LEVEL 7 SF TOTAL:NONE LEVEL 8 TOTAL: 3,020 SF TOTAL PUBLIC AMENITY: 11,136 SF TOTAL LOT AREA: 44,545 SF NOTE: PUBLIC ACCESS TO THE ROOF TOP AMENITY SHALL BE MANAGED AROUND HOTEL EVENTS FOR GUESTS AND ELEVATOR ACCESS BY THE GENERAL PUBLIC SHALL BE MAINTAINED. PREVIOUS RIGHT OF WAY NOT TABULATED IN TOTAL AMENITY P007 ROOFTOP BAR AND SPA WORLD CUP TERRACEDINING TERRACE TERRACE PUBLIC ARRIVAL SKIER ACCESS VACATED SOUTH ASPEN STREET ROW VACATED SUMMIT STREET ROW TERRACE PUBLIC AMENITY PLAN SCALE: 1”-30’ DESIGN WORKSHOP Landscape Architecture · Land Planning · Urban Design · Tourism Planning 120 East Main Street · Aspen, Colorado 81611 · 970-925-8354 Facsimile 970-920-1387 G o r s u c h H a u s A s p e n , C o l o r a d o JANUARY 15, 2020 ILLUSTRATIVE PERSPECTIVE P008 ILLUSTRATIVE PERSPECTIVE WORLD CUP P009 DESIGN WORKSHOP Landscape Architecture · Land Planning · Urban Design · Tourism Planning 120 East Main Street · Aspen, Colorado 81611 · 970-925-8354 Facsimile 970-920-1387 G o r s u c h H a u s A s p e n , C o l o r a d o JANUARY 15, 2020 ILLUSTRATIVE PERSPECTIVE ARRIVAL AT SOUTH ASPEN STREEET P010 DESIGN WORKSHOP Landscape Architecture · Land Planning · Urban Design · Tourism Planning 120 East Main Street · Aspen, Colorado 81611 · 970-925-8354 Facsimile 970-920-1387 G o r s u c h H a u s A s p e n , C o l o r a d o JANUARY 15, 2020 R200 2 R201 2 LEVEL 1 WALL ABOVE BOILER ROOM 24 ' - 0 " 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5 TOWER 4 1:20 1:12 PARKING 7,985.00' AJ 2 R250 3 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 7,988.00' 21 BQ 1 R250 1 R251 A100 1 7,988.00' 7,985.50' MA T C H L I N E PROPERTY LINE FAN ROOM SERVICE ELEVATOR PIT ELEVATOR 1 PIT ELEV. LOBBY ELEVATOR 2 PIT UP STAIR 2 STAIR 1 TOTAL SPACES: 56 STALLS 1 4 2 3 5 6 7 8 9 1110 30 31 42 4132 35 3736 38 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 56 55 54 53 52 51 50 49 48 47 46 45 44 43 33 34 40 39 40 39 33 SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R100 REFERENCE PLAN - LEVEL P1 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL P1 (7988') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 ARRIVAL LOBBY R200 2 R201 2 3 5' - 0" BELL CONCIERGE PROPERTY LINE 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5TOWER 4 AJ 2 R250 3 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A101N 1 RECEPTION 7,998.50' 7,999.00' MA T C H L I N E GM VESTIBULE ELEVATOR 2 EMERGENCY GENERATOR MAIN ELECTRICAL FIRE CONTROL CENTER HSK SUPPORT ELEV. LOBBY SERVICE STAIR 02 RECEPTION CONTROLLER MENSWOMENS TELECOM FIRE PUMP WATER ENTRY ELEVATOR 1 VALET LUGGAGE ENGINEERING SKI STORAGE SECURITY MULTI-USE RECEIVING CUST. BREAK ROOMHR ACCT OFFICE OWNERS STORAGE SALES LOADING / RECEIVING UNIFORM ADMIN SERVICE CORRIDOR MECH DN PARKING GARAGE VENTILATION FIREPLACE TRASH AND RECYCLING approx. 12'x33' = 400sf DEDICATED TRASH/RECYCLING AREA. PERMANENT MARKINGS ON WALL AND FLOOR TO INDICATE AREA NOT TO BE USED FOR ANY OTHER PURPOSE. GREASE INTERCEPTOR SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R101 REFERENCE PLAN - LEVEL 01 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE:1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 01 (7999') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 WARMING KITCHEN R200 2 R201 2 ELECTRICAL MEETING / BANQUET 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5 TOWER 4 AJ 2 R250 3 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A102N 1 MECHANICAL AFFORDABLE HOUSING UNIT 8,009.50' MA T C H L I N E PROPERTY LINE MEN MTG STORAGE KING KING KING KING ELEVATOR 2 SERVICE STAIR 02 KING KING ELEVATOR 1 PRE-FUNCTION SERVICE CORRIDOR STORAGE CORRIDOR WOMEN F&B OFFICE F&B SALES GREEN ROOF GREEN ROOF 1/8" / 1'-0"OPEN TO BELOWSHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R102 REFERENCE PLAN - LEVEL 02 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 02 (8009.5') DETAILED REVIEW APPLICATION 15 JAN 2020 5T 72 24 5T60 24 5T60 24 5T 48 24 5T 48 24 5T48 24 5T48 245T 48 24 5T72 18 5T72 18 5T72 18 5T72 18 5T 36 24 5T48 24 5T36 24 5T 72 24 5T36 14 5T30 14 JAN. BEV/SERVER ICE COOKEXPO SERVICE ADA SERVICE HOST HOST SERV. PANTRY SH E L F S H E L F SH E L F SHELF UNIVERS AL MOP 20-8 H FISHER2445 D C D DC DBL RACK CH E M D H H C H C 14 5T72 14 5T72 R200 1 KITCHEN R200 2 R201 2 OUTDOOR MECH. CHILLER YARD 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5 TOWER 4 AJ 2 R250 3 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A103N 1 RESTAURANT MA T C H L I N E PROPERTY LINE LIBRARY KING KING KING KING KING 8,020.50' RESTROOM RESTROOM SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R103 REFERENCE PLAN - LEVEL 03 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 03 (8020.5') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 BOOT ROOM R200 2 R201 2 OPEN TO COOLING TOWER BELOW FITNESS 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD WORLD CUP BAR LIFT CENTERLINE ALIGNMENTTOWER 5 TOWER 4 OPEN TO BELOW AJ 2 R250 3 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A104N 1 A104S 1 MA T C H L I N E PROPERTY LINE Q/Q KING KING KING KING KING KING KING KING EXT.Q/Q Q/Q KING 8,031.00' 8,031.00' MECH SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R104 REFERENCE PLAN - LEVEL 04 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 04 (8031') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 R200 2 R201 2 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5 TOWER 4 AJ 2 R250 3 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A105N 1 A105S 1 MA T C H L I N E PROPERTY LINE RIDGEVALLEYVALLEYKINGKINGKING Q/QQ/QKING EXT. Q/Q KING KING EXT. Q/Q STAIR 02 KING KING ADA KINGKING KING EXT. CORRIDOR Q/Q KING KING STAIR 03 SPA 8,041.50' SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R105 REFERENCE PLAN - LEVEL 05 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 05 (8041.5') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 R200 2 R201 2 R2011 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5 TOWER 4 AJ 2 R250 3 R251 2 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A106N 1 A106S 1 MA T C H L I N E PROPERTY LINE ADA KING Q/QQ/QKING EXT. KINGKINGKING KING SUITE SUITE KINGKINGKINGKING KING KING KING KING KING 8,052.00' SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R106 REFERENCE PLAN - LEVEL 06 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE:1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 06 (8052') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 R200 2 R201 2 SPA EQUIP R2011BOH 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5 TOWER 4 AJ 2 R250 3 R251 2 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A107N 1 A107S 1 8,062.50' MA T C H L I N E PROPERTY LINE KINGQ/QQ/Q KING KING ADA KING KING KING KING KING KING KING KING KING KING EXT. KINGKINGKINGKING KING KING EXT. VOID VOID SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R107 REFERENCE PLAN - LEVEL 07 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 07 (8062.5') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 CONDO LODGE R200 2 R201 2 CONDO LODGE CONDO LODGE CONDO LODGE R2011 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENT TOWER 5 AJ SPA 12' X 28'2 R250 3 R251 2 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A108S 1 8,074.00' MA T C H L I N E PROPERTY LINE 8,073.00' 8,067.70' 8,067.75' 8,073.00' 2,000sf2,000sf 2,000sf 2,000sf 8,072.95' 8,072.95' STORAGE/SUPPORT UNISEX UNISEX UNISEX ELEVATOR 4 STAIR 03 SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R108 REFERENCE PLAN - LEVEL 08 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 08 (8073') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 CONDO LODGE CONDO LODGE R200 2 R201 2 CONDO LODGE CONDO LODGE R2011 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENTTOWER 5 AJ 2 R250 3 R251 2 R251 3 AO 19171513117591 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A109S 1 MA T C H L I N E PROPERTY LINE open to below open to below 8,084.00' 8,084.00' SHEET NOTES: 1. ARCH ELEV 100'-0" = CIVIL ELEV 7999'-0" TYP ALL SHEETS 2. PLANS SHOWN ARE FOR NOTATIONAL USE ONLY. REFER TO A100 AND A200 SERIES FOR ARCHITECTURAL INFORMATION. 3. EAST & WEST ELEVATIONS SHOWN ARE FOR REFERENCE ONLY. ELEVATIONS ARE FULLY REFERENCED IN A200 SERIES. 4. BUILDING SECTIONS SHOWN ARE FOR REFERENCE ONLY. SECTIONS ARE FULLY REFERENCED IN A200 SERIES ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R109 REFERENCE PLAN - LEVEL 09 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 REFERENCE PLAN - LEVEL 09 (8082') DETAILED REVIEW APPLICATION 15 JAN 2020 R200 1 R200 2 R201 2 R2011 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD LIFT CENTERLINE ALIGNMENT TOWER 5 TOWER 4 AJ 2 R250 3 R251 2 R251 3 AO 1917151311 7 5 91 BT BR BE BJ.2 BG.5 21 BQ 1 R250 1 R251 A110N 1 A110S 1 MA T C H L I N E RIDGEVALLEYVALLEYRIDGE RI D G E RI D G E RIDGEVALLEYVALLEYRIDGEVALLEYVALLEYRI D G ERIDGEPROPERTY LINE 8,074.00'8,076.00' 3" / 1 ' - 0 " 3" / 1 ' - 0 " 1" / 1'-0" 2 3 / 4 " / 1 ' - 0 " 2 3 / 4 " / 1 ' - 0 " 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0"3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0"3" / 1 ' - 0 " 3" / 1 ' - 0 " 3" / 1 ' - 0 " 3" / 1 ' - 0 " 3" / 1'-0" 3" / 1'-0" FLAT ROOF FLAT ROOF FLAT ROOF FLAT ROOF FLAT ROOF 3 " / 1'- 0 " 3 " / 1'- 0 " OCCUPIABLE ROOF FLAT ROOF W/ INTERNAL DRAINS AND VEGETATION DIAMOND PATTERN SOLAR TILES POOL DECK TERRACE - FLAT ROOF W/ INTERNAL DRAINS AND PEDESTAL PAVER SYSTEM ROOF LEGEND FLAT ROOF W/ INTERNAL DRAINS ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER R110 REFERENCE PLAN - ROOF 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 ROOF DETAILED REVIEW APPLICATION 15 JAN 2020 5T72 24 5T72 24 5T 60 24 5T 60 24 5T 60 24 5T 60 24 5T 36 24 5T66 24 5T 72 24 5T 72 24 BEV/SERVICE DISH ASSEMBLYPLATING STOR. HOTHOLDING REF. REF. FR.FR. STORAGE ICE D WINS T O N CAC - 5 2 2 D WIN S T O N CAC- 5 2 2 D WIN S T O N CAC- 5 2 2 DBL RACK TRUE T-49F TRUE T-49F U N IVER SAL MOP 20-8 1331NEW AGE 1331NEW AGE 1331NEW AGE AIRIN DD C AIROUT HOSH I Z A K I K M - 1 3 0 1 S A H 3 D 1331NEW AGE RDRD RDRD 5T 72 24 5T60 24 5T60 24 5T 48 24 5T 48 24 5T48 24 5T48 245T 48 24 5T72 18 5T72 18 5T72 18 5T72 18 5T 36 24 48 24 36 24 5T 72 24 5T36 14 5T30 14 JAN. BEV/SERVER ICE COOKEXPO SERVICE ADA SERVICE HOST HOST SERV. PANTRY SH E L F S H E L F SH E L F SHELF UNIVERSAL MOP 20-8 H FISHER2445 D C D DBL RACK CH E M D H H C H C 14 5T72 14 5T72 PASTRY /CARVERY BAR PICK UP POS SERVICE LODGE COMMERCIAL RESIDENTIAL AFFORDABLE HOUSING NON-UNIT SPACE (SHARED) EXEMPTIONS OPEN TO BELOW USE LEGEND *FAR CALCULATED PURSUANT TO LAND USE CODE SECTION 26.575.020 NOTE: CALCULATIONS SUBJECT TO CHANGE AS BUILDING DESIGN IS REFINED DURING PERMITTING STAGE A B C D 133' - 2" 211' - 11" 133' - 2" 211' - 11" 1' - 0 " 10 ' - 0 " 1' - 0 " 10 ' - 0 " EXPOSED WALL (Xlf) x X'(h) = XXXX SF PERCENTAGE OF EXPOSED EXTERIOR WALL = 00% *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 NON EXPOSED WALL 598LF X 10'(h) = 5980 sf NON-UNIT SPACE =19,600 sf 19,600 sf A B C D E 133' - 2" 7' - 5 1/2"13' - 8"3' - 2" 1' - 6 " 9' - 0 " 1' - 6 " 9' - 0 " *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 147' - 8" 11' - 0"34' - 4"2' - 8" EXPOSED WALL 180.5lf x 9'(h)=1,624.5 sf NON EXPOSED WALL 483.75lf x9'(h) = 4,353.75 sf PERCENTAGE OF EXPOSED EXTERIOR WALL = 27% EXP WALL sf(1624.5) / (EXP+NON EXP)sf(5978.25sf)= 27% COMMERCIAL= LODGE= NON-UNIT SPACE = EXEMPTIONS = (-100 sf) 180 sf 2,986 sf 8,532 sf 11,598 sf 44' - 7" F G H I J 20' - 0"84' - 9" 4' - 10 1/2" 18' - 6" 15' - 9 1/2" 9' - 5 1/2" K 4' - 10 1/2" 16' - 2"92' - 1" L A B C D G 21' - 0"71' - 0"20' - 8" 26' - 3" 6' - 8" 1' - 6 " 9' - 0 " 1' - 6 " 9' - 0 " EXPOSED WALL (305.5 lf) x 9'(h) - roof = 2,749.5 SF NON EXPOSED WALL 134.3(lf) x 9'(h) = 1,208.7 SF *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 EXP WALL SF (2749.5 SF ) /(EXP + NON EX PSF) (3,958.2 sf) = 69.5% PERCENTAGE OF EXPOSED EXTERIOR WALL = 69.5% LODGE= NON-UNIT SPACE = COMMERCIAL= 8,745 sf 1,043 sf 1,078 sf 10,866 sf 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " 30' - 0"110' - 1 1/2" 93' - 9"26' - 1 1/2"20' - 3" E 15' - 9" 9' - 0 " F 1' - 10" 9' - 0 " H 1' - 7" 9' - 0 " A B C D F 96' - 0"11' - 10" 25' - 0"88' - 4 1/2" 49' - 0" 113' - 3" 6' - 8 1/2" 1' - 6 " 9' - 0 " 1' - 6 " 9' - 0 " *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 EXP WALL SF (2758.5 SF ) /(EXP + NON EX PSF) (4101.3 sf) = 67.3% PERCENTAGE OF EXPOSED EXTERIOR WALL = 67.3% EXPOSED WALL 306.5(lf) x 9(h) = 2,758.5 sf NON EXPOSED WALL 149.2(lf) x 9'(h) = 1,342.8 SF LODGE= COMMERCIAL = NON-UNIT SPACE = 2,783 sf 5,723 sf 1,790 sf 10,296sf 58' - 10" E 6' - 8 1/2" A B C D 133' - 8" 10' - 4 1/2"123' - 4" 1' - 6 " 9' - 6 " 1' - 6 " 9' - 6 " *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 EXPOSED WALL 212.5'(lf)x9.5'(h)=2,018.75 sf NON EXPOSED WALL 298.67'(lf) x 9.5'(h) =2837.37 sf PERCENTAGE OF EXPOSED EXTERIOR WALL =41.57% EXP WALLsf (2,018.75 sf) / EXP +EX SF (4,856.12 sf) = 41.57 % LODGE= COMMERCIAL = NON-UNIT SPACE = AFFORDABLE HOUSIING = 8,058 sf 742 sf 2,441 sf 804 sf 12,045 sf 9' - 6 " 9' - 6 " 9' - 6 " 75' - 7"26' - 1"20' - 11" 122' - 7 1/2" 19600 SF NON-UNIT SPACE (SHARED) A B C D B 133 ' - 0 3 / 4 " 211' - 11 5/8" 133 ' - 0 3 / 4 " ramp up slope dn slope dn LODGE = 2986 sf NON-UNIT SHARED SPACE = 8532 sf UNCONDITIONED RAMP A B C H J D E G I K L COMMERCIAL = 180 sf F LODGE = 8058 SF NON-UNIT SHARED SPACE = 2441 Sf AFFORDABLE HOUSING = 804 SF COMMERCIAL = 742 SF A C OPEN BD 2783 SF LODGE NON-UNIT SPACE (SHARED) = 1790 SF COMMERICAL = 5723 SF exterior COVERED EXTERIOR SPACE A B C D E F NON-UNIT SPACE= 1,043 SF LODGE 8,745 SF COMMERCIAL 1,078SF open to below D G areawell vo i d u n d e r r o o f vo i d u n d e r r o o f A B H C F E ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER G031 PROPOSED FLOOR AREA CALCULATIONS 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE:1" = 40'-0"1 PARKING LEVEL 01_FAR SCALE:1" = 40'-0"2 LEVEL 01_FAR SCALE: 1" = 40'-0"3 LEVEL 02_FAR SCALE: 1" = 40'-0"4 LEVEL 03_FAR SCALE: 1" = 40'-0"5 LEVEL 04_FAR DETAILED REVIEW APPLICATION 15 JAN 2020 RDRD RDRD RDRD RDRD RDRD RDRD FDFD FDFD FDFD FDFD FDFD FDFD RDRD RDRD RDRD LODGE COMMERCIAL RESIDENTIAL AFFORDABLE HOUSING NON-UNIT SPACE (SHARED) EXEMPTIONS OPEN TO BELOW USE LEGEND *FAR CALCULATED PURSUANT TO LAND USE CODE SECTION 26.575.020 NOTE: CALCULATIONS SUBJECT TO CHANGE AS BUILDING DESIGN IS REFINED DURING PERMITTING STAGE A B D F G 43' - 6" 14' - 10" 45' - 0"135' - 9" 1' - 6 " 9' - 0 " 1' - 6 " 9' - 0 " EXPOSED WALL 442.6lf) x 9'(h) = 3983.4 sf NON EXPOSED WALL (167.5lf) x 9'(h) = 1507.5 sf *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 137' - 3" 79' - 0" 27' - 10" C 1' - 6" H 12' - 0" EXP WALL sf (3983.4 sf ) /(EXP + NON EX sf) (5490.9 sf) = 72.54% PERCENTAGE OF EXPOSED EXTERIOR WALL = 72.54% LODGE= NON-UNIT SPACE = 13,084 sf 860 sf 13,944 sf 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " I 7' - 4 1/2" J 107' - 6 1/2" 9' - 0 " 9' - 0 "E 1' - 5" 9' - 0 " 9' - 0 " A B C E 162' - 3" 16' - 0" 1' - 6 " 9' - 0 " 1' - 6 " 9' - 0 " EXPOSED WALL (434.45lf) x 9'(h) = 3910sf NON EXPOSED WALL (140.75lf) x 9'(h) = 1266.75 sf *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 34' - 0" 86' - 6" EXP WALL SF (3910 sf ) /(EXP + NON EX PSF) (5176.75 sf) = 75.5% PERCENTAGE OF EXPOSED EXTERIOR WALL =75.5% LODGE= NON-UNIT SPACE = 10,889 sf 860 sf 11,749 SF 9' - 0 " 9' - 0 " 9' - 0 " 72' - 9" D 34' - 0"162' - 3" 9' - 0 " 9' - 0 " F G 2' - 3" 9' - 0 " 5' - 4" 9' - 0 " A B C D E F 192' - 0" 16' - 0" 5' - 6" 81' - 7" 192' - 0" 5' - 6" G 1' - 6 " 9' - 0 " 1' - 6 " 9' - 0 " EXPOSED WALL (469.67lf) x 9'(h) = 4,227 sf NON EXPOSED WALL (81.7lf) x 9'(h) = 735.3 sf PERCENTAGE OF EXPOSED EXTERIOR WALL = 85.2% *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 H 12' - 0"46' - 8" LODGE= NON-UNIT SPACE = 11,966 sf 573 sf 12,539 sf 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " 9' - 0 " EXP WALL SF (4227 sf ) /(EXP + NON EX PSF) (4962.3 sf) = 85.2% EXEMPTIONS =372 sf A B C D 103' - 7 1/2" 74' - 9" 103' - 7 1/2" 74' - 9" 1' - 6 " 9' - 0 " 1' - 6 " 9' - 0 " EXPOSED WALL (356.77lf) x 9'(h) = 3210.9 SF NON EXPOSED WALL (0lf) x 0'(h) = 0 SF PERCENTAGE OF EXPOSED EXTERIOR WALL = 100% *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 RESIDENTIAL = NON-UNIT SPACE = 5,441 sf 1,027 sf 6,468 sf EXEMPTIONS = 457sf A B C D 70' - 0" 1' - 6 " 13 ' - 0 " 1' - 6 " 9' - 0 " EXPOSED WALL = 2896 SF NON EXPOSED WALL (0lf) x X'(h) = 0 SF PERCENTAGE OF EXPOSED EXTERIOR WALL = 100% *FLOOR STRUCTURE NOT INCLUDED PER 26.575.020.D.8 RESIDENTIAL =3,192 sf 3,192 sf 75' - 0" 13 ' - 0 " 8' - 0 " 8' - 0 " 13 ' - 0 " 32' - 0" 13 ' - 0 " 13084 SF LODGE NON-UNIT SPACE = 860 A C G B E D 78 ' - 1 1 3 / 4 " H I J 10889 SF LODGE NON-UNIT SPACE = 860 SF B G A C D E F 11966 SF LODGE NON-UNIT SPACE (SHARED) 573 sf B G H C A D E F C A NON-UNIT SPACE = 1,027 SF VOID BD RESIDENTIAL = 5441 SF RESIDENTIAL= 3192 C D B A ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER G032 PROPOSED FLOOR AREA CALCULATIONS 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE:1" = 40'-0"1 LEVEL 05_FAR SCALE: 1" = 40'-0"2 LEVEL 06_FAR SCALE: 1" = 40'-0"3 LEVEL 07_FAR SCALE:1" = 40'-0"4 LEVEL 08_FAR SCALE: 1" = 40'-0"5 LEVEL 09_FAR DETAILED REVIEW APPLICATION 15 JAN 2020 5T72 24 5T72 24 5T 60 24 5T 60 24 5T 60 24 5T 60 24 5T 36 24 5T66 24 5T 72 24 5T 72 24 BEV/SERVICE DISH ASSEMBLYPLATING STOR. HOTHOLDING REF. REF. FR. FR. STORAGE ICE DC WINST O N CAC- 5 2 2 D C WIN S T O N CAC-5 2 2 D C WIN S T O N CAC-5 2 2 DBL RACK TRU E T - 4 9 F TRUE T - 4 9 F TRUE T-49F TRUE T-49F U N IVER SAL MOP 20-8 HCFISHER2445 1331NEW AGE 1331NEW AGE 1331NEW AGE AIRIN DD C AIROUT H O S H I Z A K I K M - 1 3 0 1 S A H 3 D 1331NEW AGE RDRD RDRD 5T 72 24 5T60 24 5T60 24 5T 48 24 5T 48 24 5T48 24 5T48 245T 48 24 5T72 18 5T72 18 5T72 18 5T72 18 5T 36 24 48 24 36 24 5T 72 24 5T36 14 5T30 14 JAN. BEV/SERVER ICE COOKEXPO SERVICE ADA SERVICE HOST HOST SERV. PANTRY SH E L F S H E L F SH E L F SHELF UNIVERSAL MOP 20-8 H FISH ER2445 D C D DC DBL RACK CH E M D H H C H C 14 5T72 14 5T72 PASTRY /CARVERY BAR PICK UP POS SERVICE RDRD RDRD RDRD RDRD RDRD RDRD FDFD FDFD RDRD RDRD RDRD LEASABLE LIVABLE -LODGE LIVABLE -RESIDENTIAL LIVABLE -AFFORDABLE HOUSING LEASABLE / LIVABLE LEGEND *LEASABLE / LIVABLE CALCULATED PURSUANT TO LAND USE CODE SECTION 26.575.020.I. NOTE: CALCULATIONS SUBJECT TO CHANGE AS BUILDING DESIGN IS REFINED DURING PERMITTING STAGE COMMERCIAL = 180SF LODGE = 2394 SF COMMERCIAL = 548 SF (BELOW GRADE 25% REDUCTION APPLIES) AFFORDABLE HOUSING = 750 SF LODGE = 1944 SF COMMERCIAL = 4230 SF (BELOW GRADE 25% REDUCTION APPLIES) LODGE = 5010 SF COMMERCIAL = 1031 SF LODGE = 7704SF LODGE = 7858 sf LODGE = 9,112 sf FREE MARKET= 4870 FREE MARKET = 3000 SF ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER G033 PROPOSED FLOOR AREA CALCULATIONS 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE:1" = 40'-0"1 LEVEL 01_LEASABLE SCALE: 1" = 40'-0"2 LEVEL 02_LEASABLE SCALE: 1" = 40'-0"3 LEVEL 03_LEASABLE SCALE:1" = 40'-0"4 LEVEL 04_LEASABLE SCALE: 1" = 40'-0"5 LEVEL 05_LEASABLE SCALE: 1" = 40'-0"6 LEVEL 06_LEASABLE SCALE:1" = 40'-0"7 LEVEL 07_LEASABLE SCALE: 1" = 40'-0"8 LEVEL 08_LEASABLE SCALE: 1" = 40'-0"9 LEVEL 09_LEASABLE DETAILED REVIEW APPLICATION 15 JAN 2020 15' OFFSET FROM EXTERIOR WALL @ GRADE 8060 805580 5 0 8065 8 0 7 0 8075 80 4 5 80 4 0 8035 8030 8025 8020 8010 8000 8 0 0 0 8010 8 0 1 5 8 0 2 0 802580308035 8040 8045 8050 8055 8060 8065 8070 8,079.00' 1 2 3 4 5 6 78 9 10 1112 13 14 15 16 17 18 1920 21 22 2324 25 26 2728 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 8,099.90' FA C E O F E X T E R I O R W A L L 8,099.90' 8055 80 6 5 80 6 0 80 5 0 80 4 5 80 4 0 8,072.80'8,076.05' 8,071.65' 8,072.80'8,076.05' 8,072.80' 80 3 5 80 3 0 80 2 5 80 2 0 8,096.40' 8,095.55' 8,096.05' 8,099.70' 8,096.05' 8,096.40' 8,096.50' 8,090.70' 8,090.70'8,090.70' 8,090.50' 8,097.00' 8,090.70' 8,083.15' 8,077.45' 8,076.40' 8,076.95' 8,053.65'8,053.65' 8,079.00' 8,079.00' 8,079.00' 8,045.90'8,045.90' 8,053.65' 8,052.20' 8,072.90' 8,077.40' 8,052.20' 8,052.20' 8,053.65' 8,031.75' 8,031.75' 8,041.20' 8,031.75' 8,031.75' 8,020.45' 8,015.45' 8,009.45' 8,030.90'8,030.90' 8,083.15' 8075 8015 8005 ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER G034 HEIGHT PLAN - PROPOSED GRADE 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"1 HEIGHT PLAN - PROPOSED GRADE DETAILED REVIEW APPLICATION 15 JAN 2020 LEVEL 01 (7999') 78' - 6" LEVEL 02 (8009'-6") 89' - 0" LEVEL 03 (8020'-6") 100' - 0" LEVEL 04 (8031') 110' - 6" LEVEL 05 (8041'-6") 121' - 0" LEVEL 06 (8052') 131' - 6" LEVEL 07 (8062'-6") 142' - 0" LEVEL 08 (8073') 152' - 6" LEVEL 09 (8082') 162' - 6" ROOF (8098'-6") 178' - 0" AF AD ABAEAK.5 AK AI ACAGAHAJAO LEVEL 01 (7999') 78' - 6" LEVEL 02 (8009'-6") 89' - 0" LEVEL 03 (8020'-6") 100' - 0" LEVEL 04 (8031') 110' - 6" LEVEL 05 (8041'-6") 121' - 0" LEVEL 06 (8052') 131' - 6" LEVEL 07 (8062'-6") 142' - 0" LEVEL 08 (8073') 152' - 6" LEVEL 09 (8082') 162' - 6" ROOF (8098'-6") 178' - 0" 14 12 10 8 46161820 231917151311759 121 ALLOWABLE DORMER PER 26.575.020.F.2.g HIGHEST RIDGE POINT AT ELEVATION 8,077.4' ACCEPTABLE STAIR / ELEVATOR OVERRUN PER 26.575.020.f.4.c HIGHEST CORNER AT ELEVATION 8,082.65' ALLOWABLE DORMER PER 26.575.020.F.2.g ACCEPTABLE ELEVATOR OVERRUN PER 26.575.020.f.4.c HIGHEST CORNER AT ELEVATION 8,090.5' ALLOWABLE DORMER PER 26.575.020.F.2.g HIGHEST RIDGE POINT AT ELEVATION 8,097.00' METAL CLAD WOOD WINDOWS, TYP. HEAVY TIMBER POSTS, STAINED WOOD BALCONY RAILING STONE VENEER WOOD SIDING, TYP. ROOFTOP POOL TERRACE W/ GLASS RAILING ACCEPTABLE PERMANENT ROOFTOP AMENITY PER 26.575.020.f.4.k ROOF MID-POINT 8,039.75' T.O. SHEATHING ROOF MID-POINT 8,065.00' T.O. SHEATHING ROOF MID-POINT 8,073.35' T.O. SHEATHING 8,088.20' T.O. SHEATHING ROOF MID-POINT 8,097.15' T.O. SHEATHING ROOF MID-POINT PROPOSED GRADE 40'-0" OFFSET INTERPOLATED NATURAL GRADDE 40'-0" OFFEST ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER D200 BUILDING ELEVATIONS 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE:1/16" = 1'-0"1 NORTH ELEVATION SCALE: 1/16" = 1'-0"2 EAST ELEVATION LEVEL 01 (7999') 78' - 6" LEVEL 02 (8009'-6") 89' - 0" LEVEL 03 (8020'-6") 100' - 0" LEVEL 04 (8031') 110' - 6" LEVEL 05 (8041'-6") 121' - 0" LEVEL 06 (8052') 131' - 6" LEVEL 07 (8062'-6") 142' - 0" LEVEL 08 (8073') 152' - 6" LEVEL 09 (8082') 162' - 6" ROOF (8098'-6") 178' - 0" 141210846 16 18 202319171513117591 21 8,039.75' T.O. SHEATHING ROOF MID-POINT 8,065.00' T.O. SHEATHING ROOF MID-POINT 8,073.35' T.O. SHEATHING ROOF MID-POINT 8,090.00' T.O. SHEATHING ROOF MID-POINT 8,097.15' T.O. SHEATHING ROOF MID-POINT INTERPOLATED NATURAL GRADE 40'-0" OFFEST PROPOSED GRADE 40'-0" OFFSET METAL CLAD WOOD WINDOWS HEAVY TIMBER POSTS, STAINED WOOD SIDING, TYP WOOD BALCONY RAILING ALLOWABLE DORMER PER 26.575.020.F.2.g ACCEPTABLE ELEVATOR OVERRUN PER 26.575.020.f.4.c HIGHEST CORNER AT ELEVATION 8,090.5' ALLOWABLE DORMER PER 26.575.020.F.2.g HIGHEST RIDGE POINT AT ELEVATION 8,097.00' ROOFTOP POOL TERRACE W/ GLASS RAILING ACCEPTABLE PERMANENT ROOFTOP AMENITY PER 26.575.020.f.4.k ALLOWABLE DORMER PER 26.575.020.F.2.g HIGHEST RIDGE POINT AT ELEVATION 8,077.4' ACCEPTABLE STAIR / ELEVATOR OVERRUN PER 26.575.020.f.4.c HIGHEST CORNER AT ELEVATION 8,082.65' STONE VENEER STAIR BEYOND LEVEL 07 (8062'-6") 142' - 0" LEVEL 08 (8073') 152' - 6" LEVEL 09 (8082') 162' - 6" ROOF (8098'-6") 178' - 0" BIBN BDBTBRBEBJ.2 BG.5BQ ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER D201 BUILDING ELEVATIONS 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING SCALE: 1/16" = 1'-0"2 WEST ELEVATION SCALE: 1/16" = 1'-0"1 SOUTH ELEVATION 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD AJ 3 AO 1917151311 7 5 91 BT BR BE BJ.2 BG.5 21 BQ LIFT CENTERLINE ALIGNMENT TOWER 5 TOWER 4 RIDGEVALLEYVALLEYRIDGE RI D G E RI D G E RIDGEVALLEYVALLEYRIDGEVALLEYVALLEYRI D G E FLAT ROOFRIDGEPROPERTY LINE 8,074.00'8,076.00' 1 1 3" / 1 ' - 0 " 3" / 1 ' - 0 " 1" / 1'-0" 1 1 1 1 1 1 2 3 / 4 " / 1 ' - 0 " 2 3 / 4 " / 1 ' - 0 " 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0"3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" FLAT ROOF 3" / 1 ' - 0 " 3" / 1 ' - 0 " 3" / 1 ' - 0 " 3" / 1 ' - 0 " 3" / 1'-0" 3" / 1'-0" 2 2 2 2 2 2 2 2 OCCUPIABLE ROOF FLAT ROOF FLAT ROOF FLAT ROOF 1 1 1 3" / 1' -0 " 3 " / 1'- 0 " SPA TIMBER SNOW FENCE SYSTEM LEGEND 1 OSHA FALL PROTECTION ANCHOR2 AREA OF SNOW MELT FLAT ROOF W/ INTERNAL DRAINS AND VEGETATION DIAMOND PATTERN SOLAR TILES POOL DECK TERRACE - FLAT ROOF W/ INTERNAL DRAINS AND PEDESTAL PAVER SYSTEM ROOF LEGEND FLAT ROOF W/ INTERNAL DRAINS ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER G050 SNOW SHEDDING ROOF PLAN 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING 0'4'8'16' SCALE:1/16" = 1'-0"1 SNOW SHEDDING PLAN 3" / 1 ' - 0 " 1" / 1'-0" 3" / 1'-0" 3" / 1'-0" 3" / 1'-0" 14121084 AF AD AB AE AK.5 6 16 18 20 AK AI AC 2 AG AH BI BN BD AJ 3 AO 1917151311 7 5 91 BT BR BE BJ.2 BG.5 21 BQ Calculated pursuant to City of Aspen Land Use Code Section 26.575.020.F.2.g DORMER SF / TOTAL ROOF SF = DORMER COVERAGE DORMERS Zone 1: 540sf / 2,156sf = 25% Zone 2: 3,692sf / 8,656sf = 43% Zone 3: 0sf / 606sf = 0% Zone 4: 1,978sf / 7,454sf = 27% Zone 5: 0sf / 1,359sf = 05 Zone 6: 1,624sf / 5,621sf = 29% Total: 7,834sf / 25,852sf = 30% 5 5 6 4 3 2 1 ZONEZONE ZONE ZONE ZONE ZONE ZONE ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER G051 DORMER PLAN 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING DETAILED REVIEW APPLICATION 15 JAN 2020 0'4'8'16' SCALE:1/16" = 1'-0"1 ROOF_DORMER CALCULATIONS ISS. # 4240 Architecture Inc. copyright 2019 ARCHITECT'S PROJECT NO. : DESIGNER: DRAFTER: CHECKER: APPROVED BY: KEY PLAN DESCRIPTION DATE NOT FOR CONSTRUCTION OWNER A801 MATERIAL BOARD 21222.00 Designer Author Checker Approver AS P E N , C O 8 1 6 1 1 GO R S U C H H A U S NORWAY ISLAND, LLC ASPEN, CO 81611 STUDIO NYL 2995 BASELINE RD., SUITE 314 BOULDER, CO STRUCTURAL ENGINEER BG BUILDINGWORKS 1626 COLE BLVD. SUITE 300 LAKEWOOD, CO 80401 MEP ENGINEER INTEGRAL GROUP 3000 LAWRENCE STREET DENVER, CO 80216 SUSTAINABILITY GEILER & ASSOCIATES 12355 E. CORNELL AVENUE AURORA, CO 80014 ACOUSTICAL ENGINEER 186 LIGHTING DESIGN GROUP 1200 BANNOCK STREET DENVER, CO 80204 LIGHTING DETAILED REVIEW APPLICATION 15 JAN 2020 EXTERIOR MATERIALS PALETTE DRY STACK GREY STONE -REGIONALLY SOURCED -RANDOM ASHLAR PATTERN -TO BE USED ON RETAINING WALLS LABELED AS TYPE A ON SITE PLAN. 1x6 OR 1x8 WOOD CLADDING -CLEAR STAIN WITH INTERGRATED FIRE RETARDANT -HORIZONTAL AND VERTICAL APPLICATIONS SUNSTYLE PHOTOVOLTAIC ROOF -GREY SHINGLES -35"x35" PANELS WITH APPROXIMATE 26"x26" EXPOSURE -OCCURS AT SLOPED ROOFS WOOD SOFFITS AND BEAMS -T&G WOOD SOFFIT BOARDS -HEAVY TIMBER COLUMNS, BEAMS, AND PURLINS WOOD BALCONY RAILINGS -WOOD POSTS WITH DECORATIVE CAP FLASHING -HORIZONTAL WOOD RAILS -VERTICAL PICKETS WITH DECORATIVE CUTOUTS AT SELECT LOCATIONS GREEN ROOF -DROUGHT TOLERANT, REGIONAL SPECIFIC VEGETATION LAZER CUT METAL SCREEN -UTILIZED FOR SCREENING TRANSFORMERS AND CUSTOM LOUVERS AT LOADING DOCK CRAFTED METAL CONNECTIONS ZOLA ALUMINUM CLAD WOOD WINDOWS AND DOORS -DARK ALUMINUM EXTERIOR CLADDING CUSTOM METAL GUTTERS & DOWNSPOUTS -GALVANIZED METAL EXTERIOR PAVERS W/ SNOWMELT SYSTEM -GRAY GRANITE 1x8 HORIZONTAL FRT WOOD CLADDING 1x8 VERTICAL FRT WOOD CLADDING T&G WOOD SOFFITS GREEN ROOF SUNSTYLE PHOTOVOLTAIC ROOF WOOD BALCONY RAILINGS ZOLA ALUMINUM CLAD WOOD WINDOWS AND DOORS DRY STACK GREY STONE HEAVY TIMBER COLUMNS, BEAMS AND PURLINS EXTERIOR PAVERS W/ SNOWMELT SYSTEM 5" THICK STONE CAP EXPOSED GALVANIZED STEEL COLUMN AT REVEAL CAPLESS CLEAR GLASS RAILING AT ROOF TERRACE BALCONY MOUNTED FLOWER BOXES (BY OWNER) CUSTOM METAL DOWNSPOUTS CUSTOM WOOD OUT-SWING CARRIAGE DOORS -LOADING DOCK / GARAGE ENTRY DOORS VICINITY MAP C.1.00 COVER & GENERAL NOTES C.1.01 OVERALL SITE PLAN C.1.02 SNOW STORAGE PLAN C.1.03 EMERGENCY FIRE STAGING PLAN C.2.00 CUL-DE-SAC PLAN, PROFILE & GRADING C.2.01 CUL-DE-SAC SECTIONS C.2.02 CUL-DE-SAC SIDEWALK PLAN & PROFILES C.2.03 CONCEPTUAL PERIMETER GRADING PLAN C.2.04 MOUNTAIN ROAD PLAN, PROFILE & GRADING C.2.05 MOUNTAIN ROAD SECTIONS C.2.06 WEST SWALE PLAN, PROFILE & SECTIONS C.2.07 MUDFLOW MITIGATION PLAN C.3.00 MASTER CONCEPTUAL UTILITY PLAN C.3.01 RUTHIE'S SANITARY SEWER SERVICE PLAN & PROFILE C.3.02 GORSUCH HAUS SANITARY SEWER SERVICE PLAN & PROFILE C.3.03 16" WATER MAIN PLAN & PROFILE STA: 0+00-2+50 C.3.04 16" WATER MAIN PLAN & PROFILE STA: 2+50-END C.3.05 GORSUCH WATER SERVICE PLAN & PROFILE C.4.00 EXISTING OFFSITE DRAINAGE BASIN PLAN C.4.01 POST DEVELOPMENT DRAINAGE BASIN PLAN C.4.02 CONCEPTUAL MASTER DRAINAGE PLAN C.4.03 ONSITE CONCEPTUAL WATER QUALITY TREATMENT PLAN C.4.04 WEST OFFSITE STORM PLAN & PROFILE C.4.05 EAST OFFSITE STORM PLAN & PROFILE STA: 20+00-22+50 C.4.06 EAST OFFSITE STORM PLAN & PROFILE (STA:22+50-END) C.5.00 SITE DETAILS C.5.01 SANITARY SEWER DETAILS C.5.02 COA WATER DETAILS CIVIL PLAN INDEX 1.CONCRETE MATERIAL AND PLACEMENT SHALL BE CDOT CLASS D MIX, WITH 4500 PSI COMPRESSIVE STRENGTH. 2.WEATHER PROTECTION SHALL BE PROVIDED IN COMPLIANCE WITH CDOT STANDARD SPECIFICATIONS (LATEST STANDARDS) SECTION 412 & 601. 3.PERMITTEE SHALL SCHEDULE A FORM INSPECTION AND OBTAIN APPROVAL PRIOR TO POURING WITHIN CITY OF ASPEN RIGHT-OF-WAY. 4.DAMAGED CONCRETE PAVEMENT SHALL BE REMOVED AND REPLACED AS A FULL PANEL SECTION WITH DOWELS SET INTO ADJACENT PANELS IN COMPLIANCE WITH CDOT STANDARD SPECIFICATIONS FOR ROAD & BRIDGE CONSTRUCTION AND M&S STANDARDS (LATEST EDITION). 5.DAMAGED FLATWORK AND CURB AND GUTTER SHALL BE REPLACED IN FULL SECTIONS FROM EXISTING CONTRACTION JOINTS. PARTIAL SECTION REPLACEMENT SHALL NOT BE PERMITTED. 6.CONCRETE REMOVED ADJACENT TO ASPHALT PAVEMENTS SHALL BE SAWCUT A MINIMUM OF 2' STRIP ALONG THE ABUTTING EDGE PRIOR TO REMOVAL IN ORDER TO REMOVE WITHOUT DAMAGE TO THE ASPHALT PAVEMENT. THE SAWCUT EDGE SHALL NOT BE USED AS A FORM FOR THE NEW CONCRETE. TEMPORARY FORMWORK SHALL BE PLACED ALONG THE SAWCUT EDGE IN THE DESIRED ALIGNMENT. THE TOP EDGE OF THE REPLACED CONCRETE SECTION (CONC. LIP) SHALL BE STRAIGHT AND TRUE WITHOUT WARPING OR IRREGULARITY. AFTER THE FORMWORK IS REMOVED, THE GAP SHALL BE RE-PAVED WITH ASPHALT. DAMAGE CAUSED TO THE EDGE OF THE ASPHALT PAVEMENT SHALL RESULT IN THE ASSESSMENT OF A RESTORATION FOR ASPHALT RESURFACING. 7.SUBGRADE ELEVATION SHALL BE BROUGHT UP TO +/- 0.05 FOOT OF FINAL GRADE PER PLANS, WITH APPROVED MATERIALS PRIOR TO PLACING FORMS. 8.NO WATER SHALL BE PLACED ON CONCRETE SURFACE TO ASSIST FINISHING. 9.VARIATIONS OF CONCRETE SURFACE SHALL NOT EXCEED 1 8 INCH IN TEN FEET (10') IN ALL DIRECTIONS. 10.LIQUID MEMBRANE CURING COMPOUND SHALL BE PLACED IN COMPLIANCE WITH CDOT STANDARD SPECIFICATIONS (LATEST EDITION) SECTION 601.13.36 AT A RATE TO COMPLETELY COAT ALL EXPOSED SURFACES. 11.PERMITTEE SHALL BE RESPONSIBLE FOR REPAIRING SIDEWALK, CURB, OR GUTTER DAMAGED FROM WORK ACTIVITIES OF PERMITTEE. 12.PERMITTEE SHALL BE RESPONSIBLE FOR INSTALLATION OF NEW SIDEWALK, CURB AND GUTTER PER CITY CODE, AND FOR REPAIR OF SIDEWALK, CURB AND GUTTER PER CITY CODE. 13.SIDEWALKS MUST BE CONSTRUCTED WITH 4 INCH THICK CONCRETE AND MUST HAVE 4500 PSI COMPRESSIVE STRENGTH WITHIN 28 DAY MAX. CURING PERIOD. 80 PERCENT OF THIS STRENGTH MUST BE ACHIEVED IN 7 DAYS FOLLOWING PLACEMENT OF CONCRETE. 14.ALL CONTRACTION JOINTS SHALL BE SAWN JOINTS AND MUST BE CUT WITHIN 12 HOURS OF PLACEMENT. SAWN JOINTS SHALL BE STRAIGHT AND TRUE AND 3-6mm IN WIDTH AND 1/3 OF CONCRETE THICKNESS AND CUT AT INTERVALS EQUAL TO THE WIDTH OF SIDEWALK. 15.BASE FOR FLATWORK SHALL BE AT LEAST 6" OF CDOT CLASS 6 ABC COMPACTED TO 95% OF STANDARD PROCTOR DENSITY WITHIN 2% OF OPTIMUM MOISTURE. 16.COARSE BROOM FINISH SHALL BE PROVIDED PERPENDICULAR TO THE DIRECTION OF PEDESTRIAN TRAVEL ON SIDEWALK AND RAMPS AND PERPENDICULAR TO THE DIRECTION OF WATER FLOW ON CURB AND GUTTER. 1.ALL WATER MAIN CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION OF THE CITY OF ASPEN WATER DEPARTMENT DESIGN STANDARDS. 2.NO PVC PIPE IS ALLOWED ON POTABLE WATER SYSTEMS. 3.THE PIPE BEDDING MATERIAL SHALL BE 3 4" INCH CRUSHED SCREENED ROCK HAULED IN FOR BEDDING AND NOT NATIVE EXCAVATED MATERIAL. 4.THE BACKFILL MATERIAL FROM 12 INCHES ABOVE THE TOP OF THE PIPE TO THE TOP OF THE TRENCH SHALL BE CLASS 6 AGGREGATE BASE COURSE MATERIAL. 5.MINIMUM COVER OF WATER MAINS AND SERVICE LINES SHALL BE 7 FEET DEEP FROM TOP OF PIPE TO FINISHED GRADE. MAXIMUM DEPTH AT FINISHED GRADE WILL NOT EXCEED 10 FEET. 6.ALL FITTINGS MUST HAVE MEGA LUG FITTINGS IN ADDITION TO CONCRETE THRUST BLOCKS. 7.VALVES: GATE VALVES SHALL BE INSTALLED FOR ALL VALVES 12" AND SMALLER AND SHALL BE A MUELLER OR PREAPPROVED EQUIVALENT RESILIENT SEAT, EPOXY COATED MECHANICAL JOINT, NON-RISING VALVE STEM AND SHALL OPEN BY TURNING TO THE LEFT, COUNTER-CLOCKWISE. VALVES SHALL CONFORM TO AWWA SPECIFICATIONS C-509; OR THE LATEST REVISION THEREOF; SHALL BE CLASS 250 MUELLER OR PREAPPROVED EQUIVALENT. VALVES GREATER THAN 12" WILL BE SPECIFIED ON A CASE BY CASE BASIS, DEPENDING ON THE PRESSURES THAT WILL BE ACCOMMODATED BY THE VALVES. IN ZONES WHICH HAVE STATIC PRESSURES GREATER THAN 80 PSI THE VALVE APPLICATION WILL BE A CLASS 250 BUTTERFLY VALVE OF THE ABOVE MENTIONED MANUFACTURERS WITH EPOXY INTERIOR AND EXTERIOR COATINGS. AT INTERSECTIONS, GATE VALVES SHALL BE INSTALLED WITHIN 3' OF A TEE, CROSS, OR BEND, ALL CONNECTIONS SHALL HAVE MEGA-LUGS ON THE FITTINGS EXCEPT WHERE THE TEE BRANCH AND BRANCH VALVE ARE FLANGED. ALL MECHANICAL JOINT FITTINGS WILL HAVE MEGA-LUG FITTINGS, AND CONCRETE THRUST BLOCKS OR TIE RODS (ONLY WERE APPROVED). 8.ALL SERVICE TAPS SHALL BE PERFORMED BY THE CITY OF ASPEN WATER DEPARTMENT. 9.THE CITY OF ASPEN POLICY DOES NOT ALLOW WATER LINE INSTALLATION BETWEEN NOVEMBER 1 AND APRIL 15TH. 10.A PRE-CONSTRUCTION MEETING IS REQUIRED PRIOR TO COMMENCING ANY WORK. 11.ALL VALVES CONNECTING TO THE CITY OF ASPEN WATER SYSTEM SHALL BE OPERATED BY THE CITY OF ASPEN WATER DEPARTMENT PERSONNEL ONLY. 1.ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF ASPEN'S LATEST DESIGN STANDARDS UNLESS OTHERWISE NOTED. ALL WORK ITEMS NOT COVERED WITHIN THE CITY'S DESIGN STANDARDS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST REVISION OF THE COLORADO DEPARTMENT OF TRANSPORTATION'S STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION AND M & S STANDARDS. 2.THE EXISTING CONTOUR INTERVAL IS ONE (1) FOOT (DASHED). EXISTING CONDITIONS ARE BASED ON AN IMPROVEMENT SURVEY PERFORMED BY SOPRIS SURVEYING INC.. 3.ALL EXISTING UTILITIES EITHER UNDERGROUND OR OVERHEAD, SHALL BE MAINTAINED IN CONTINUOUS SERVICE THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. THE CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR ANY DAMAGE TO, OR INTERRUPTION OF SERVICES CAUSED BY THE CONSTRUCTION. 4.ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A SET OF APPROVED CONSTRUCTION DOCUMENTS ON SITE AT ALL TIMES. 5.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING CONDITIONS OUTSIDE THE DESIGNATED IMPROVEMENT AREA FROM DAMAGE. ANY DAMAGE TO EXISTING AREAS OUTSIDE THE DESIGNATED IMPROVEMENT AREA DURING CONSTRUCTION SHALL, AT A MINIMUM, BE RESTORED TO A STATE EQUAL TO ITS PRE CONSTRUCTION STATE. 6.THE GENERAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS TO COMPLETE WORK, AND SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. IDENTIFYING THE NEED FOR A PERMIT, PREPARING THE APPLICATION, AND PAYING THE SUBMITTAL AND REVIEW FEES NECESSARY TO SECURE PERMITS WILL BE THE TOTAL RESPONSIBILITY OF THE GENERAL CONTRACTOR. A COPY OF ALL PERMITS MUST BE POSTED AND WEATHER PROOFED ON SITE AT ALL TIMES. 7.THE GENERAL CONTRACTOR SHALL PERFORM THE WORK ACCORDING TO ALL LOCAL GOVERNMENT, COUNTY, STATE, AND FEDERAL SAFETY AND HEALTH REGULATIONS. IN PARTICULAR, THE "TRENCHING" AND "OPEN EXCAVATION" OPERATIONS SHALL COMPLY WITH ALL CURRENT O.S.H.A. REGULATORY REQUIREMENTS. 8.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING THEIR OWN DISPOSAL SITE FOR ALL DISPOSED MATERIALS. 9.COORDINATION WITH OTHER AGENCIES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING INSPECTIONS PERFORMED BY OTHER GOVERNMENTAL AGENCIES, AND THE ENGINEER OF RECORD, AS PRESCRIBED IN THEIR PERMITS AND APPROVALS. 10.MAINTAIN TRAFFIC CONTROL DEVICES: THE CONTRACTOR SHALL INSTALL AND MAINTAIN FENCES, BARRIERS, LIGHTS AND SIGNS THAT ARE NECESSARY TO GIVE ADEQUATE WARNING TO THE PUBLIC AND TRAVELING MOTORISTS AT ALL TIMES. 11.NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT PRIOR APPROVAL FROM THE CITY. 12.NOTIFY UTILITY OWNERS: CONTRACTOR SHALL NOTIFY ALL PUBLIC OR PRIVATE UTILITY OWNERS FORTY-EIGHT HOURS (OR AS REQUIRED BY UTILITY COMPANIES) PRIOR TO COMMENCEMENT OF WORK ADJACENT TO THE UTILITY. 13.IT IS THE CONTRACTORS RESPONSIBILITY TO SCHEDULE INSTALLATION INSPECTIONS AND SCHEDULE/OBTAIN AS-BUILT SURVEY DATA DURING CONSTRUCTION OF ALL IMPROVEMENTS TO INCLUDE, BUT NOT LIMITED TO, STORM PIPE INVERTS AT ALL BENDS, INLETS, OUTFALLS, EXCAVATED DEPTHS OF WATER QUALITY TREATMENT AREAS, AND UTILITY INFRASTRUCTURE. THE CONTRACTOR SHALL REFER TO THE CITY'S GRADING AND DRAINAGE CERTIFICATE REQUIREMENTS FOR FURTHER INFORMATION. THIS DOCUMENT IS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 14.COORDINATION WITH OTHER CONTRACTORS: WHERE TWO OR MORE CONTRACTORS ARE WORKING IN THE SAME AREA, EACH SHALL CONDUCT THEIR OPERATIONS IN SUCH A MANNER AS NOT TO CAUSE ANY UNNECESSARY DELAY OR HINDRANCE TO THE OTHER. WHERE CONFLICTS CANNOT BE AVOIDED, THE LOCAL GOVERNMENT WILL DETERMINE WHICH CONTRACTOR(S) HAVE CONSTRUCTION PRIORITY OVER THE OTHER CONTRACTORS AND THE TERMS OF SUCH CONSTRUCTION PRIORITY. 15.THE CONTRACTOR AND SUB-CONTRACTOR MUST MAKE EVERY ATTEMPT TO PREVENT DAMAGE TO EXISTING TREES AND ASSOCIATED ROOTS IN AND AROUND THE SUBJECT PROPERTY. 1.ALL SEWER LINES CONSTRUCTION SHALL MEET OR EXCEED THE FOLLOWING PLAN NOTE DETAIL AND CONSTRUCTION SPECIFICATIONS. 2.ALL SEWER SERVICES SHALL BE PVC CLASS-SDR 26. 3.FITTINGS: PVC PUSH JOINT-ASTM D1784. 4.CLEAN ALL PIPE, FITTINGS AND RELATED MATERIALS THOROUGHLY OF ALL FOREIGN MATERIAL AND INSPECT FOR CRACKS, EXCESSIVE DEFLECTION FLAWS OR OTHER DEFECTS PRIOR TO AND AFTER INSTALLATION. 5.THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT ANY CONSTRUCTION DEBRIS FROM ENTERING THE SEWER LINES DURING CONSTRUCTION. IF THIS DEBRIS SHOULD ENTER THE PIPE LINE SYSTEM, THE CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIALS NECESSARY TO CLEAN THE SYSTEM. UNDER NO CIRCUMSTANCES WILL THE CONTRACTOR FLUSH THE DEBRIS INTO AN EXISTING SANITARY SEWER SYSTEM. 6.ALL PIPES MUST BE INSTALLED WITH A LASER. IF BENDING OF THE BEAM DUE TO AIR TEMPERATURE VARIATIONS BECOMES APPARENT WITH "IN PIPE" UNITS, A FAN SHALL BE PROVIDED TO CIRCULATE AIR IN THE PIPE. AIR VELOCITY SHALL NOT BE SO EXCESSIVE AS TO CAUSE PULSATING OR VIBRATING OF THE BEAM. IF, IN THE OPINION OF THE ENGINEER, THE BEAM CANNOT BE ACCURATELY CONTROLLED, THIS METHOD OF SETTING LINE AND GRADE SHALL BE ABANDONED. 7.PIPE SHALL BE LAID TRUE TO LINE AND GRADE, IN AN UPHILL DIRECTION, WITH BELL ENDS FACING IN THE DIRECTION OF LAYING. WHEN PIPE LAYING IS NOT IN PROGRESS, THE OPEN END OF PIPE SHALL BE CLOSED BY A WATERTIGHT PLUG. 8.MANHOLES & CLEANOUTS SHALL BE FURNISHED AND INSTALLED TO DEPTHS AND DIMENSIONS SHOWN ON THE CONSTRUCTION DRAWINGS AND/OR STAKED IN THE FIELD. MANHOLES SHALL BE CONSTRUCTED OF CAST-IN-PLACE OR PRECAST CONCRETE IN ACCORDANCE WITH DETAILS SHOWN ON THE CONSTRUCTION DRAWINGS. 9.CONNECTIONS TO EXISTING SEWER FACILITIES WHERE LIVE FLOWS EXIST SHALL BE MADE ONLY AFTER PRIOR CONSULTATION WITH AND RECEIPT OF WRITTEN PERMISSION FROM THE ENGINEER. NO BYPASS OF SEWAGE TO THE SURFACE WILL BE ALLOWED IN THE COMPLETION OF THIS CONNECTION. CONNECTIONS SHALL BE MADE AS SHOWN ON THE DRAWINGS. ALL CONNECTIONS BETWEEN PIPES OF DIFFERENT MATERIALS SHALL BE MADE WITH APPROVED MANUFACTURED CONNECTORS. 10.THE CONTRACTOR IS REQUIRED TO CCTV THE EXISTING SEWER SERVICE LINE TO DETERMINE MATERIAL, DEPTH AND CONDITION. IF MATERIAL TYPE IS NOT PVC AND/OR IF SERVICE LINE CONSISTS OF IRREGULAR SLOPES AND/OR IF DEGRADATION OF EXISTING SERVICE LINE IS OBSERVED THE ENTIRE SERVICE LINE SHALL BE REPLACED WITH SDR-26 PVC PIPE. 1.PUBLIC IMPROVEMENTS SHALL BE IN COMPLIANCE WITH THE CITY OF ASPEN ENGINEERING STANDARDS AND CITY OF ASPEN ROW STANDARDS. PUBLIC IMPROVEMENTS IN THE ROW MUST MEET THE CITY'S CONSTRUCTION AND EXCAVATION STANDARDS. 2.THE PUBLIC PEDESTRIAN AREAS HAVE BEEN DESIGNED PER THE AMERICAN'S WITH DISABILITIES ACT (ADA) STANDARDS. THE MAIN PEDESTRIAN CORRIDORS HAVE BEEN DESIGNED WITH A MAXIMUM CROSS SLOPE OF 2%. THE CONTINUOUS LONGITUDINAL SLOPES ARE ALL LESS THAN THE MAXIMUM 5% SLOPE. HANDICAP RAMPS WILL BE CONSTRUCTED PER ADA AND THE COA STANDARD DETAILS. PAVEMENT REMOVAL: 1.ALL ASPHALT PAVEMENT CUTS SHALL BE IN STRAIGHT NEAT LINES. IRREGULAR SHAPED CUTS WITH MORE THAN FOUR (4) SIDES OR CUTS WITHIN EXISTING PATCHES SHALL NOT BE ALLOWED. ALL CUTS SHALL BE RECTANGULAR IN SHAPE, AND EDGES SHALL BE PARALLEL OR PERPENDICULAR TO THE FLOW OF TRAFFIC. 2.IN ORDER TO PROVIDE STRAIGHT EDGES, ALL ASPHALT PAVEMENT CUTS SHALL BE CUT BY A MECHANICAL SAW CUTTING EQUIPMENT, ROTOMILLING, OR OTHER APPROVED METHOD WHICH ASSURES A NEAT STRAIGHT EDGE FOR THE REQUIRED DEPTH OF THE CUT. 3.ASPHALT PAVEMENT CUTS SHALL BE SUCH THAT NO LONGITUDINAL JOINT LIES WITHIN THE WHEEL TRACK; ANY PATCH WHICH PENETRATES A WHEEL PATH MUST BE EXTENDED TO FULL LANE WIDTH. 4.CONCRETE PAVEMENT SHALL BE REMOVED AND REPLACED FROM EXISTING PANEL JOINTS ONLY. 5.STRESS CRACKING OF EXISTING PAVEMENT MAY OCCUR DURING EXCAVATION FOR A VARIETY OF REASONS. IF THIS OCCURS, THE CONTRACTOR MUST SAWCUT AT LEAST 12" BEYOND THE LIMIT OF VISIBLE CRACKS AND REMOVE ALL STRESSED PAVEMENT. ASPHALT PAVEMENTS: 6.THE MINIMUM PATCH DIMENSIONS SHALL BE TWO FEET (2') BEYOND EACH SIDE OF THE TRENCH OR EXCAVATION BUT SHALL NOT EXTEND INTO AN ADJACENT UNDISTURBED LANE OR CROSS THE STREET CENTER LINE. REFER TO CITY OF ASPEN LATEST STANDARDS. 7.THE LONGITUDINAL EDGES OF THE PATCH SHALL NOT FALL WITHIN THE EXISTING WHEEL TRACKS WHENEVER POSSIBLE. 8.PRIOR TO PLACING THE PERMANENT PATCH, THE EXISTING PAVEMENT SHALL BE SAWCUT TO A NEAT STRAIGHT-LINE, SQUARE TO THE TRAVEL LANE. 9.ASPHALT MIX SHALL BE CDOT, S-MIX (3 4"). PATCH BACK AREAS GREATER THAN ONE HUNDRED TWENTY SQUARE FEET (120 S.F.) SHALL REQUIRE THE SUBMITTAL AND APPROVAL OF A MIX DESIGN TO THE ENGINEER PRIOR TO PLACEMENT. 10.COMPACTION SHALL BE AT LEAST 95% OF MAX. DENSITY WITHIN 2% OPTIMUM MOISTURE AS DEFINED BY ASTM 1557 METHOD "C". 11.COMPACTION EQUIPMENT SHALL BE CAPABLE OF COMPACTING CORNERS AND EDGES OF PATCH. 12.HOT BITUMINOUS PATCHES SHALL BE PLACED A MIN. OF 5-INCHES OR MATCH EXISTING DEPTH, WHICHEVER IS GREATER. PLACEMENT SHALL BE PERFORMED IN A MIN. OF 2 LIFTS. THE BOTTOM COURSE SHALL BE 3-INCHES AND THE TOP SHALL BE 2-INCHES. 13.PATCHES SHALL ALSO HAVE A CROSS SLOPE SECTION CONSISTENT WITH THE DESIGN OF THE EXISTING ROADWAY. 14.TEMPORARY OR PERMANENT ASPHALT PATCHES SHALL BE PLACED WITHIN TWENTY FOUR (24) HOURS OF TRENCH BACKFILLING. WHENEVER PERMANENT PATCHES ARE NOT CONSTRUCTED WITHIN TWENTY FOUR (24) HOURS FOLLOWING TRENCH BACKFILLING OPERATIONS, TEMPORARY PAVEMENT PATCHES CONSISTING OF A MINIMUM OF THREE INCHES (3") OF HOT OR COLD PLANT MIX OR STEEL PLATES MUST BE PLACED TO PROVIDE THE REQUIRED NUMBER OF PAVED TRAVEL LANES. TEMPORARY PAVEMENT PATCHES MAY BE LEFT IN PLACE FOR A MAX. OF FIVE (5) WORKING DAYS FOLLOWING COMPLETION OF BACKFILLING OPERATIONS UNLESS OTHERWISE APPROVED BY THE ENGINEER OF RECORD OR THE CITY PAVING INSPECTOR . 15.THE PERMITTEE SHALL MONITOR TEMPORARY PATCHES ON A DAILY BASIS AND TEMPORARY PATCHES EXHIBITING RUTS, HUMPS, OR DEPRESSIONS SHALL BE REPAIRED OR REPLACED IMMEDIATELY. 16.A PERMANENT HOT PATCH SHALL BE MADE WITHIN FIVE (5) DAYS AFTER THE AREA IS OPEN TO TRAFFIC, WEATHER PERMITTING. 17.IF FINAL PATCHING IS NOT COMPLETED WITHIN THE SPECIFIED TIME, NO NON-EMERGENCY PERMITS SHALL BE GRANTED TO THE PERMITTEE UNTIL ALL OUTSTANDING WORK IS COMPLETED. 18.UPON COMPLETION OF THE PERMANENT PATCH, THE SURFACE SHALL BE THOROUGHLY COMPACTED, SMOOTH AND FREE FROM RUTS, HUMPS, DEPRESSIONS, OR IRREGULARITIES. WHEN A STRAIGHTEDGE TEN FEET (10') LONG IS LAID ACROSS THE PERMANENT PATCH PARALLEL TO THE CENTERLINE, THE SURFACE SHALL NOT VARY MORE THAN 1 4 " FROM THE LOWER EDGE OF THE STRAIGHT EDGE. PATCHES EXHIBITING DEVIATIONS GREATER THAN 1 4" SHALL BE REPLACED PRIOR TO ACCEPTANCE OF PATCH. IF THE EXISTING STREET EXCEEDS THE ABOVE TOLERANCES, THEN THE PATCH SHALL BE EQUAL OR BETTER THAN THE CONDITION OF THE SURROUNDING PAVEMENT. IN MOST CASES, AND PARTICULARLY IN THE CASES OF EXTENSIVE EXCAVATION AND REPAIRS, IT IS DESIRABLE TO SURVEY THE EXISTING PAVEMENT CONDITIONS WITH A REPRESENTATIVE OF THE CITY PRIOR TO THE WORK. AFTER COMPLETION OF THE WORK, SURVEY THE PAVEMENT CONDITION AGAIN TO VERIFY THAT THE PAVEMENT CONDITION HAS BEEN MAINTAINED OR IMPROVED. IN THE CASE OF MINOR REPAIRS, THESE PAVEMENT SURVEYS CAN BE MADE BY VISUAL OBSERVATION. 1.CONTRACTOR MUST UTILIZE "BEST MANAGEMENT PRACTICES" (BMP), TO CONTROL EROSION AND SEDIMENTATION DURING CONSTRUCTION, TO INCLUDE THE INSTALLATION OF INLET PROTECTION AROUND THE NEAREST DOWNSTREAM RECEIVING INLET LOCATED WITHIN THE CITY'S ROW. 2.CONTRACTOR IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF ALL TEMPORARY EROSION CONTROL MEASURES. 3.DUST CAUSED BY EXCAVATION, TOPSOIL REMOVAL OPERATIONS, OR ROAD BASE PLACEMENT SHALL BE CONTROLLED BY THE CONTRACTOR AT HIS EXPENSE. THE ENGINEER OR CITY MAY REQUIRE THE CONTRACTOR AT ANY TIME TO DISCONTINUE CONSTRUCTION ACTIVITIES UNTIL DUST CONDITIONS ARE REDUCED TO THE CITY'S SATISFACTION. 4.THE CONTRACTOR WILL BE REQUIRED TO FURNISH AND APPLY A DUST PALLIATIVE ON THE SITE AS DIRECTED BY THE CITY. DUST PALLIATIVE MAY CONSIST OF WATER OR A NON-POLLUTING SOLUTION. SPREADING OF WATER OR WATER MIXTURE SHALL BE DONE WITH ACCEPTABLE SPRINKLING EQUIPMENT. ALL DUST CONTROL SHALL EXTEND BEYOND THE CONSTRUCTION AREA PROPER TO THE SIDE STREETS ENTERING AND EXISTING THE PROJECT, WHERE MUD AND DIRT FROM CONSTRUCTION EQUIPMENT, AS WELL AS LOCAL TRAFFIC, MAY GET ONTO THE SIDE STREETS. CLEANUP OF THESE AREAS WILL BE REQUIRED AS NECESSARY OR AS DIRECTED BY THE CITY/OWNER/ENGINEER. 5.MAINTENANCE OF PROPER DRAINAGE AND CLEANING TEMPORARY SEDIMENT CONTAINMENT DURING THE PROGRESS OF THE CONTRACT IS ESSENTIAL. ANY DAMAGE DUE TO IMPROPER MAINTENANCE OF SAID DRAINAGE PRIOR TO FINAL ACCEPTANCE OF THE PROJECT WILL BE THE CONTRACTOR'S RESPONSIBILITY. 6.BMP’S SHALL BE INSTALLED BEFORE ANY EARTH DISTURBING ACTIVITIES COMMENCE. 7.STORMWATER DISCHARGES FROM CONSTRUCTION ACTIVITIES SHALL NOT CAUSE, HAVE THE REASONABLE POTENTIAL TO CAUSE, OR MEASURABLY CONTRIBUTE TO AN EXCEEDANCE OF ANY WATER QUALITY STANDARD. 8.CONSTRUCTION SHALL BE PHASED IN A MANNER TO LIMIT EARTH DISTURBING ACTIVITIES (I.E. THE ENTIRE PROJECT SITE SHOULD NOT BE DISTURBED IF CONSTRUCTION WILL ONLY BE OCCURRING IN ONE PARTICULAR SECTION). 9.SEDIMENT CAUSED BY ACCELERATED SOIL EROSION SHALL BE REMOVED FROM RUNOFF WATER BEFORE IT LEAVES THE CONSTRUCTION SITE. 10.BULK STORAGE STRUCTURES FOR PETROLEUM PRODUCTS AND ANY OTHER CHEMICALS SHALL HAVE SECONDARY CONTAINMENT OR EQUIVALENT PROTECTION TO CONTAIN ALL SPILLS AND PREVENT ANY SPILLED MATERIAL FROM ENTERING STATE WATERS. 11.THE EROSION CONTROL PLAN SHALL BE CONTINUOUSLY UPDATED TO REFLECT NEW OR REVISED BEST MANAGEMENT PRACTICES (BMP’S) DUE TO CHANGES IN DESIGN, CONSTRUCTION, OPERATION, OR MAINTENANCE OF THE CONSTRUCTION SITE. UPDATES MUST BE MADE WITHIN 72 HOURS FOLLOWING THE CHANGE IN BMP’S. 12.THE CONTRACTOR SHALL INSPECT THE CONSTRUCTION SITE (INCLUDING ALL BMP’S, STORAGE CONTAINERS, AND CONSTRUCTION EQUIPMENT) A MINIMUM OF EVERY 14 CALENDAR DAYS AND WITHIN 24 HOURS AFTER A PRECIPITATION EVENT OR SNOW MELT THAT MAY CAUSE SURFACE EROSION. 13.THE CONTRACTOR SHALL KEEP A RECORD OF ALL INSPECTIONS ON SITE AND AVAILABLE FOR REVIEW BY CITY STAFF. INSPECTION REPORTS MUST IDENTIFY ANY INCIDENTS OF NON-COMPLIANCE WITH THE TERMS AND CONDITIONS OF THE PERMIT. 14.STRAW BALES SHALL NOT BE USED FOR PRIMARY EROSION OR SEDIMENT CONTROL (I.E. STRAW BALES MAY BE USED FOR REINFORCEMENT BEHIND ANOTHER BMP SUCH AS SILT FENCE). 15.BMP’S INTENDED FOR SHEET FLOW SEDIMENT RUNOFF SHALL BE PLACED PARALLEL TO THE SLOPE. 16.ALL BMP’S SHALL BE CLEANED WHEN SEDIMENT LEVELS ACCUMULATE TO HALF THE DESIGN OF THE BMP UNLESS OTHERWISE SPECIFIED. 17.A VEHICLE TRACKING PAD (VTP) SHALL BE PLACED AT ALL EXITS FROM THE SITE TO PREVENT TRACK-OUT ONTO CITY STREETS. IF TRACK-OUT DOES OCCUR, THE CONTRACTOR SHALL IMMEDIATELY SWEEP THE STREET OF DEBRIS. 18.ALL PORTA-POTTY STRUCTURES MUST BE FIRMLY SECURED WITH #4 REBAR ANCHORS OR EQUAL. MUST BE PLACED AWAY FROM FLOW LINES OF STREET, SWALES, RAIN GARDENS & AWAY FROM INLETS. 19.A CONCRETE WASHOUT AREA (CWA) MUST BE PROVIDED AND ROUTINELY MAINTAINED. NO WASHING OUT OF CONCRETE TRUCKS OR WASHING OF SWEEPINGS FROM EXPOSED AGGREGATE CONCRETE INTO STORM DRAINS, OPEN DITCHES, STREETS OR STREAMS IS ALLOWED. 20.EXCESS CONCRETE IS NOT ALLOWED TO BE DUMPED ON-SITE, EXCEPT IN DESIGNATED TEMPORARY CONCRETE WASHOUT AREAS (CWA). 21.ON-SITE TEMPORARY CONCRETE WASHOUT FACILITIES WILL BE CONSTRUCTED AND MAINTAINED IN SUFFICIENT QUANTITY AND SIZE TO CONTAIN ALL LIQUID AND CONCRETE WASTE GENERATED BY WASHOUT OPERATIONS AND MUST BE CLEANED OUT OR REPLACED ONCE THE WASHOUT IS 75% FULL. 22.STOCKPILES OF SOIL OR OTHER ERODABLE MATERIALS MUST BE MANAGED SO THAT STORMWATER DOES NOT COME IN CONTACT WITH THE PILE AND POTENTIALLY WASH POLLUTANTS OFFSITE. AT A MINIMUM STOCKPILES SHALL BE ROUTINELY WETTED AND/OR BLANKETED AS WELL AS INCLUDE AN EROSION SOCK PERIMETER BARRIER TO PREVENT WIND EROSION AND SEDIMENT TRANSPORT OFFSITE. STOCKPILES THAT ARE INACTIVE FOR MORE THAN 7 DAYS WILL REQUIRE SOIL BINDER OR HAVE MUCLH/MULCH TACKIFIER APPLIED. 23.EROSION CONTROL BLANKETS SHALL BE INSTALLED ON ALL SLOPES EXCEEDING 3:1. GENERAL CONSTRUCTION NOTES: CONCRETE FLATWORK SPECIFICATIONS EROSION CONTROL NOTES: WATER MAIN & SERVICE INSTALLATION SPECIFICATIONS: PAVING SPECIFICATIONS: GRAVITY SANITARY SEWER SERVICE LINE INSTALLATION SPECIFICATIONS: PUBLIC IMPROVEMENTS NOTE: SCALE: 1" = 2,000' GORSUCH HAUS PROJECT A PARCEL OF LAND SITUATED IN THE NE1 4NE1 4 AND SE1 4NE1 4 OF SECTION 13 TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE 6TH P.M. CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS 15101.06 GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 1 0 : 2 3 a m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 1 . 0 0 C O V E R 1 5 1 0 1 . 0 6 . d w g CJB JKS C.1.00 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R COVER & GENERAL NOTES SITE 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 3-2-20203 DETAILED REVIEW ROW/PROPERTY LINE LANDSCAPE ISLAND; RE. TO LANDSCAPE PLANS SKI WAY WIDTH VARIES (60-FT MIN.) PROPOSED 20-FT ACCESS & UTILITY EASEMENT; RE. TO C.3.00 & PLAT LOT 2 LOT 1 5-FT SETBACK LOT 1 S. ASPEN ST. ROW HILL ST. ROW CABLE GAUGE EDGE-TELEMIX MOUN T A I N Q U E E N LOT 2 LI F T O N E L O D G E - L O T O N E LI F T O N E L O D G E - L O T T W O LI F T O N E L O D G E - L O T T H R E E S. ASPEN ST. ROW SHADOW MOUNTAIN SUBDIVISION BA R B E E F A M I L Y CO N S E R V A T I O N P A R C E L SH A D O W M O U N T A I N SU B D I V I S I O N LOT 1 LOT 2 25' ESMNT. FOR SKIERS & PEDESTRIANS PLAT BK.4 PG. 489 & WATERLINE ESMNT TO CITY OF ASPEN BK 411 PG. 996 20-FT E S M N T F O R F I R E A C C E S S & DRAIN A G E G R A N T E D T O M T . QUEE N C O N D O S B K 2 7 5 P G 3 7 8 CENTERLINE LIFT ALIGNMENT TOWER LIFT #5 TOWER LIFT #4 LOWER LEVEL STRUCTURE (TYP) SNOWMELT CONCRETE 42" SITE WALL ALONG STAIRS SCREEN WALLS FOR TRANSFORMERS WORLD CUP STAGING AREA 19.5' 23.0' FL-FL 20.0' COA ADA RAMP TYPE 6 SITE WALL FOR PED. RAMP 6' W I D E S N O W M E L T PE D . C O R R I D O R COA ADA RAMP TYPE 7 COA ADA RAMP TYPE 7 R50.0' SILVA CELLS (TYP) 17.4' TRASH ENCLOSURESNOWMELT CONCRETE PLAZA 2' PAVER & 6' SIDEWALK 9.8' FLUSH DROP OFF AREA 12.3' 4" MOUNTABLE CATCH CURB 4' DRAIN PAN 4' DRAIN PAN (16'±) TYPE B BARRIER SPILL CURB COA TYPE A BARRIER CURB (CATCH CURB) TYPE B 6" MOUNTABLE SPILL CURB COA TYPE A 6" MOUNTABLE CURB (CATCH CURB) FLUSH BARRIER CURB EGRESS STAIRWELL (SNOWM E L T ) SAW CUT CONTROL JOINTS (TYP) SOUTH ASPEN STREET SUBDIVISION SHADOW MOUNTAIN VILLAGE PROPOSED DEBRIS FLOW WALL MOUNT A I N R D ; R E . T O C . 2 . 0 4 (GRAV E L S U R F A C E ) PROPOSED GRAVEL PATH PROPOSED ELEC. EASEMENT; RE. TO C.3.00 & PLAT PROPOSED 15-FT UTILITY EASEMENT; RE. TO C.3.00 & PLAT EGRESS STAIRWELL (SNOWM E L T ) LEVEL 3 RESTAURANT TERRACE LEVEL 4 DECKDECK LEVEL 3 AT GRADE ENTRANCE BELOW SITE RETAINING WALL; RE. TO C.2.03 FOR SPOT ELEVATIONS 30' PROPOSED WATER MAIN ESMNT; RE. C.3.00 & PLAT ELEC. SWITCH GEAR ELEC. RECLOSER PROJECT XFRMR PROPOSED BIKE RACK; RE. TO LANDSCAPE PLANS HI L L S T R E E T R O W HI L L S T R E E T R O W HI L L S T R E E T R O W SKI WAY SKI WAY SKI C O . P R O P E R T Y LO T 2 PATIO P A T I O P A T I O PATIO PATIOPATIOPATIO PATIO PATIO PATIO PATIOPATIO PATIOPATIOPATIOPATIOPATIO PATIOPATIO COLUMN (TYP) COA ADA RAMP TYPE 1 ADA RAMP W/ VERT. CURB RETURNS 5.0' PROPOSED SIDEWALK DN D N DN DN GATE SCREEN GRATE ABOVE TIERED SITE RETAINING WALLS; RE. TO C.2.00 FOR SPOT ELEVATIONS EXISTING CURB WALL AROUND INLET TO REMAIN S. ASPEN ST. ROW PED. ESMNT 5' TRAIL ESMNT L O T 1 D N 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 20 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 2 : 5 1 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 1 . 0 1 - C . 1 . 0 2 S I T E P L A N - S N O W S T O R A G E 1 5 1 0 1 . 0 6 . d w g CJB JKS C.1.01 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R OVERALL SITE PLAN NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: REFER TO SHEET C.1.02 3-2-20203 DETAILED REVIEW ZONE 1 HARDSCAPE: 13,700± SF ZONE 1 STORAGE= 650± SF ZONE 1 STORAGE: 165± SF ZONE 2 SNOW STORAGE AREA: 640± SF ZONE 1 STORAGE: 223± SF ZONE 2 STORAGE AREA: 122 SF ZONE 2 STORAGE AREA:229± SF ZONE 1 STORAGE= 219± SF ZONE 3 STORAGE AREA 97± ZONE 1 STORAGE: 520± SF RE. TO G050 FOR SNOW SHEDDING ROOF PLAN ZONE 2 HARDSCAPE: 3,315± SF ZONE 3 HARDSCAPE: 1,653± SF ZONE 3 HARDSCAPE: 53± SF ZONE 3 HARDSCAPE: 78± SF HILL ST. ROW DEBRIS FLOW WALL ZONE 3 STORAGE AREA 86± ZONE 3 STORAGE AREA 87± ZONE 3 HARDSCAPE: 76± SF 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 20 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 2 : 5 2 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 1 . 0 1 - C . 1 . 0 2 S I T E P L A N - S N O W S T O R A G E 1 5 1 0 1 . 0 6 . d w g CJB JKS C.1.02 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R SNOW STORAGE PLAN ZONE 1 HARDSCAPE AREA (CUL-DE-SAC, SURROUNDING SIDEWALKS & PLAZA ZONE 1 SNOW STORAGE AREAS ZONE 2 HARDSCAPE AREA (PATIOS & EXTERIOR STAIRWAYS ALONG EAST SIDE OF BUILDING) ZONE 2 SNOW STORAGE AREAS NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. ZONE 3 HARDSCAPE AREA (PATIOS & EXTERIOR STAIRWAYS ALONG EAST SIDE OF BUILDING) ZONE 3 SNOW STORAGE AREAS 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW 3-2-20203 DETAILED REVIEW 22.0'± FL-FL SUPPORT FIRE TRUCKS (PUMPER) SECOND ARRIVING AERIAL FIRE TRUCK (LADDER) ENTERS CUL-DE-SAC CLOCKWISE. OUTRIGGERS ENGAGED AND WITHIN PAVED PORTION OF CUL-DE-SAC; IF NEEDED THIS SECOND AERIAL MASTER (ALPHA-BRAVO) CAN BE SUPPLIED BY THE ADJACENT FIRE HYDRANT STAGED AMBULANCE ALONG S. ASPEN STREET LA N D S C A P E B U F F E R SN O W M E L T S I D E W A L K SN O W M E L T S I D E W A L K EXISTING HYDRANT PROPOSED HYDRANT FIRST ARRIVING ENGINE CONNECTS TO NEW HYDRANT AND SUPPLIES THE FDC TO SUPPORT THE FIRE SPRINKLER SYSTEM. APPARATUS ENTERS CLOCKWISE TO PLACE THE PUMP PANEL ON THE STRUCTURE SIDE FOR IMPROVED VISIBILITY. PROPOSED FDC FIRST ARRIVING AERIAL FIRE TRUCK POSITIONED AT THE NORTHWEST CORNER OF THE BUILDING (ALPHA-DELTA CORNER) & ENTERS CUL-DE-SAC COUNTERCLOCKWISE. CONNECTS TO EXISTING FIRE HYDRANT ALONG S. ASPEN STREET TO PROVIDE AN ELEVATED MASTER STREAM AS NECESSARY. HATCHED AREA REFLECTS PROPOSED PLAZA/PORTE COCHERE/LOADING DOCK AREA;BE ADVISED THIS AREA MAY BE OCCUPIED WITH LOADING/UNLOADING VEHICLES BUT COULD ALSO PROVIDE ADDITIONAL FIRE DEPARTMENT ACCESS DURING AN EMERGENCY FDC SUPPLY LINES SUPPLY LINE MOUNTABLE CURB ADJACENT TO PLAZA SUPPLY LINE MOUNTABLE CURB AROUND PERIMETER OF ISLAND LIMITS OF PROPOSED SNOWMELT ASSOCIATED WITH CUL-DE-SAC IMPROVEMENTS APPROX. LOCATION OF GRADE BREAK FROM S. ASPEN STREET TO CUL-DE-SAC WA L L 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 10 ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 2 : 5 4 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 1 . 0 3 F I R E S T A G I N G E X H I B I T 1 5 1 0 1 . 0 6 . d w g CJB JKS C.1.03 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 EMERGENCY FIRE STAGING PLAN FIRE TRUCK BODY ANTICIPATED LIMITS OF OUTRIGGERS GENERAL NOTE: DUE TO THE EXTREME TERRAIN CHALLENGE OF CONSTRUCTION ON A SKI SLOPE, IT IS UNDERSTOOD THAT FIREFIGHTING OPERATIONS WILL BE CONDUCTED WITHIN AND THROUGHOUT THE STRUCTURE VIA STANDPIPE CONNECTIONS (SIMILAR TO COMMON HIGH-RISE OPERATIONS). A FIRE COMMAND CENTER IS BEING PROVIDED TO FURTHER ASSIST IN COORDINATING INTERIOR FIRE OPERATIONS. S. ASPEN STREET SNOWMELT AREA PROPOSED PLAZA, UNLOADING/LOADING & PORTE COCHERE AREA NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 2020-01-15 DRAFT-DETAILED REVIEW PROJECT NUMBER:15101.06 2 PROJECT DETAILED REVIEW 3-2-20203 DETAILED REVIEW SWITCH GEAR RECLOSE R > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >> > > > > > > x PLANTER PLANTER TW: 92.52 TW: 93.63 TW: 97.50 TW: 98.00 TW: 98.00 TW: 98.00 TW: 99.55 FUTURE TW: 96.00 FUTURE TW: 96.50 FUTURE TW: 97.00 FUTURE TW: 97.50 FUTURE TW: 98.00 FUTURE TW: 98.50 TW: 03.50 TW: 03.50 TC: 93.73 TC: 93.94 TC: 96.01 TC: 95.83 TC: 97.39 TC: 97.50 TC: 00.16 TC: 01.34 TC: 01.01 ME: 93.7'± ME: 91.4'± ME: 90.2'± 15 . 2 % 1 6 . 4 % 4 . 9 % 5 . 0 % 3 . 0 % 2. 0 % 3. 0 % 8. 3 % 8. 3 % 2.0% 2.0% 2.0% 3.5% 3.9% 4.0% 3.5% 3.5% 2.0 % 2.0 % 1 . 9 % 2 . 0 % 2 . 0 % 2 . 0 % 1.0% 2.2 % 2.2 % 2. 8 % 2. 8 % 2. 8 % 2. 8 % 2. 0 % 4.9% 1.4 % 1.2 % 2. 0 % 2. 0 % 2.0% 1.8% 1 . 9 % 1 . 7 % 2 . 0 % 1. 8 % 2 . 0 % 2.0% 2.0%3.0% 3.0% 1 . 8 % 0. 8 % 1. 0 % 2.5 % 0.7% 2. 7 % 1.0% 1.1 % 0.7% 2.1% 4.9 % 2.3 % 1 . 9 % 2. 6 % 2.6% 1 . 7 % 2.0 % 1. 8 % 2.0 % 10 . 3 % 15 . 6 % 15 . 6 % 16 . 9 % 2. 6 % 3.6% TC: 99.36 TC: 99.08 HIGH POINT TOP:7999.08' RIM: 98.87 FFE:7999.10' 2.0% TC: 98.77 RIM: 98.87TC: 99.50 TC: 99.50 TC: 99.37 TC: 99.26 TC: 99.30 TC: 99.11 FL: 99.17 TC: 99.32 FL: 99.02 TC: 99.11 TC: 99.20 TC: 99.24 TC: 98.93 FL: 98.47 FL: 98.15 TC: 99.14 TC: 98.74 TC: 98.75 TC: 98.88 TC: 98.75 TC: 98.75 TC: 99.24 TC: 99.24 TC: 98.56 TC: 98.50 TC: 98.50 TC: 98.92 TC: 97.87 TC: 97.06 TC: 92.99 TC: 91.45 TC: 90.22 STA: 1+20.02 TOC:8000.25' CENTERLINE HIGH POINT TC: 99.42 2.0% 2.0% 6.4% 5.7% 2.0% 1.9% 1. 5 % 3 . 0 % TBC: 99.27 TBC: 99.76 TBC: 00.19 TBC: 99.95 TBC: 98.21 TBC: 98.37 TBC: 98.51 TBC: 98.87 TBC: 99.83 TBC: 99.76 TBC: 99.21 TBC: 99.79 TBC: 00.27 TBC: 01.19 TBC: 00.91 TBC: 98.89 TBC: 98.05 TBC: 93.10 TBC: 91.13 TBC: 91.47 TBC: 93.39 TBC: 95.15 TBC: 97.32 TBC: 97.51 TBC: 97.62 TBC: 97.71 TBC: 97.64 TBC: 97.75 FL: 97.31 FL:7997.25' TW: 98.00 RIDGE LINE 2.0% 12.0% 12.0% 2.0% 7990 8000 8010 7992 7994 7996 7998 8002 8004 8006 8008 8012 8014 8016 8016 8016 8018 6.00' SIDEWALK TW: 06.50 FG: 97.05 2.0% 4. 0 % 2 . 0 % 1. 9 % 2.8% 3.5% 4 . 4 % BEGIN MOUNTABLE CURB TRANSITION FROM MOUNTABLE CURB TO 6" VERTICAL CURB 6" VERTICAL CURB 6" VERTICAL CURB PROPOSED SITE WALL (HATCHED) PROPOSED TRENCH DRAIN (ABOVE STRUCTURE) OVERHEAD ROOF SITE WALL EXISTING PLANTER WALL COLUMN (TYP.) PROPOSED TRENCH DRAIN ALONG EDGE OF BUILDING APPROX. LOCATION OF TOWER #4 PROP. FG: 7999.0'± PROPOSED TRENCH DRAIN 0.0 % 2.0% TBC: 02.41 FL: 00.89 8 0 0 0 80 0 0 80 0 0 79 9 8 7 9 9 8 8 0 0 2 8 0 0 2 8 0 0 2 800 0 8 0 1 0 8 0 1 0 8 0 2 0 0+ 5 0 1 + 0 0 1 + 5 0 2+00 2 + 5 0 3+00 3+ 5 0 3 + 7 3 EP: 3+72.55 PC: 0+51.30 PC: 1+13.97 PC: 3+35.29 PT: 0+97.05 PT: 3+06.34 PCC: 1+58.34 - 0 + 0 8 0 + 0 0 SITE WALL ANTICIPATED WITH LIFT ONE LODGE PATIO TC: 96.27 TC: 98.55 FFE:7999.10' TW: 06.50 TW: 06.50 TW: 09.03 TW: 12.10 TC: 00.00 TC: 99.93 TC: 99.42 TC: 99.38 TW: 09.00 FL: 07.20 FG: 08.57 SILVA CELLS (TYP.) SNOWMELTED CONCRETE 1. 4 % 7996 7998 7998 PROPOSED DEBRIS FLOW WALL (BY OTHERS) 16.00' WIDE MNT. ROAD (RE. TO C.2.04) 4.9 % 4.9 % TW: 06.50 FG: 09.29 TW: 09.50 TW: 09.50 4 . 9 % FFE:7999.25' FFE:7999.10' 1.6% 2.0% 2.0% 2 . 0 % 1.0% TC: 99.23 TC: 98.96 TC: 98.82 FL: 98.72 TC: 98.55 TC: 98.55 TC: 98.30 FL: 98.22 TC: 98.30 TC: 09.50 TC: 09.50 TC: 15.00 TC: 15.00 TC: 20.50 TW: 24.00 TW: 19.00 TW: 13.00 TW: 19.00 TW: 19.00 TW: 19.00 TW: 19.00 TW: 19.00 TW: 24.00 RIM: 98.00 RIM: 08.70 RIM: 96.80 RIM: 97.76 RIM: 97.40 RIM: 96.00 RIM: 96.86 RIM: 96.84 RIM: 97.13 RIM: 98.01 RIM: 98.08 RIM: 98.18 FG/RIM: 97.87 FG/RIM: 97.50 4 . 5 % FG: 98.75 FG: 97.48 FG: 97.32 FG: 97.15 FG: 97.05 TC: 99.14 TC: 99.05 TC: 98.95 TC: 98.49 THREE (3) 6" STEPS HILL STREET R.O.W. TW: 01.44 TW: 98.18BW: 97.44 BW: 94.18 WAT E R F E A T U R E FLUSH CURB TRANSITION FROM MOUNTABLE CATCH CURB TO MOUNTABLE SPILL CURB TRANSITION FROM MOUNTABLE CATCH CURB TO MOUNTABLE SPILL CURB 5.00 TC: 99.88 TC: 99.96 LANDSCAPE AREA MATCH EX: 02.15 MATCH EX: 00.67 7.7% 8.2% 2.1% 1.9% 15 . 4 % TW: 98.00 TC: 96.22 TC: 96.95 FG: 97.77 FG: 97.83 FG: 97.44 EXISTING: 93.4'±EXISTING: 94.3'±EXISTING: 94.6'±EXISTING: 95.1'± EXISTING: 95.6'± EXISTING: 95.7'± PROPOSED SLOT DRAIN ALONG BACK OF CURB MOUNTABLE CATCH CURB TYPE B BARRIER SPILL CURB COA TYPE A BARRIER CURB (CATCH CURB) TYPE B 6" MOUNTABLE SPILL CURB COA TYPE A 6" MOUNTABLE CURB (CATCH CURB) FLUSH BARRIER CURB 2.0% 2.0% PROPOSED SKIWAY ELECTRIC SPLICE VAULT PROPOSED 4.00 VALLEY PAN PROPOSED 4.00 VALLEY PAN CURB WALL PROPOSED FLAGPOLES (BY OTHERS) ADJUST MANHOLE RIM: 00.20 FL: 00.69 TC: 01.08FL: 01.91 FL: 02.16TBC: 02.66 RIM: 03.58 RIM: 05.28 RIM: 06.21 FL: 00.93 TBC: 00.94 2 . 0 % 2 . 0 % 2.0% ME: 93.6'± 2.0% 2.0% 2.0% 1 6 . 4 % 2 . 0 % FL: 94.82 FL: 99.56 FL: 98.39 TBC: 99.54 TC: 00.83 TC: 00.79 TC: 99.78 TC: 99.62 TC: 00.62 TC: 99.72 TC: 99.62 TC: 99.52 TC: 93.73 EX. TW: 00.27 EX. TW: 00.15EX. TW: 00.22 EX. TW: 01.20 EX. TW: 01.20 EX. INLET RIM: 99.77 TC: 98.50 TC: 98.46 TW: 19.00 TC: 15.00 TC: 15.00 TW: 09.50 TW: 13.00 TW: 06.00 TW: 06.00 TW: 04.00 TW: 13.00 TW: 13.00 TW: 13.00 TC: 09.50 TC: 02.50TW: 04.00 PROFILE SCALE: HORZ: 1" = 20' VERT: 1" = 10' EXISTING GRADE PROPOSED GRADE PROPOSED GRADEEXISTING GRADE PROFILE SCALE: HORZ: 1" = 20' VERT: 1" = 10' CUL-DE-SAC PROFILE 7982 7985 7990 7995 8000 8005 8010 8015 7982 7985 7990 7995 8000 8005 8010 8015 15.40% -1.62% -0.75% -14.43 % -2.50%-1.00% MATCH EXISTING STA = 0+00.00 ELEV = 7985.12 GRADE BREAK STA = 2+80.08 ELEV = 7997.62 GRADE BREAK STA = 3+72.55 ELEV = 7993.74 GRADE BREAK STA = 1+58.34 ELEV = 7999.42 GRADE BREAK STA = 1+86.62 ELEV = 7999.14 PVI STA: 1+02.00 PVI ELEV: 8000.83 K: 2.79 LVC: 50.00 BV C S : 0 + 7 7 . 0 0 BV C E : 7 9 9 6 . 9 8 EV C S : 1 + 2 7 . 0 0 EV C E : 8 0 0 0 . 2 1 HIGH PT. STA: 1+20.02 HIGH PT ELEV: 8000.30 PVI STA: 3+49.26 PVI ELEV: 7997.10 K: 1.83 LVC: 25.00 BV C S : 3 + 3 6 . 7 6 BV C E : 7 9 9 7 . 2 0 EV C S : 3 + 6 1 . 7 6 EV C E : 7 9 9 5 . 3 0 0+00 79 8 5 . 1 79 8 5 . 1 2 79 8 8 . 9 79 8 8 . 9 7 0+50 79 9 2 . 8 79 9 2 . 8 2 79 9 6 . 6 79 9 6 . 6 7 1+00 79 9 9 . 9 79 9 9 . 5 8 80 0 2 . 5 80 0 0 . 2 5 1+50 80 0 6 . 1 79 9 9 . 6 3 80 0 8 . 8 79 9 9 . 2 6 2+00 80 1 4 . 9 79 9 8 . 9 2 80 1 1 . 1 79 9 8 . 5 2 2+50 80 0 3 . 6 79 9 8 . 1 1 80 0 2 . 8 79 9 7 . 7 1 3+00 80 0 2 . 2 79 9 7 . 4 7 79 9 9 . 5 79 9 7 . 2 9 3+50 79 9 6 . 9 79 9 6 . 6 2 3+73 79 9 3 . 7 79 9 3 . 7 4 DRAINAGE DIRECTION/SLOPE SPOT ELEVATION EXAMPLE: TOP OF CONCRETE @ 7900.00' = BW = BOTTOM OF WALL FFE = FINISHED FLOOR ELEVATION FG = FINISHED GRADE FL = FLOW LINE GB = GRADE BREAK HP = HIGH POINT LP = LOW POINT MATCH EX = MATCH EXISTING TC = TOP OF CONCRETE TP = TOP OF PAVERS TW = TOP OF WALL SPOT ELEVATION LEGEND XXX:XX.XX' 2.0% TC:00.00' 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 10 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 0 1 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 0 - C . 2 . 0 1 C U L - D E - S A C P P & S E C 1 5 1 0 1 . 0 6 . d w g CJB JKS C.2.00 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R CUL-DE-SAC PLAN, PROFILE & GRADING 10-10-2019 SD PRICING NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. NOTES: 1.PROPOSED & EXISTING CONTOURS AT 2-FT INTERVALS 2.REFER TO LANDSCAPE PLANS FOR HARDSCAPE PATTERNS 3.REFER TO LANDSCAPE PLANS FOR PLANTING INFORMATION 4.PROPOSED GRADING ILLUSTRATES SUMMER GRADES 5.ALL EXISTING MH'S AND VALVE BOXES TO BE ADJUSTED PROJECT NUMBER:15101.06 1 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW 3-2-20203 DETAILED REVIEW SECTION AT STA: 0+96.0 7994 7996 7998 8000 8002 8004 8006 7994 7996 8000 8004 0 10 200-10 SECTION AT STA: 1+59.0 7992 7994 7996 7998 8000 8002 8004 8006 8008 8010 8012 8014 8016 7992 7996 8000 8004 8008 8012 8016 0 10 200-10-20-30-40-50-60-70 SECTION AT STA: 1+70.0 7994 7996 7998 8000 8002 8004 8006 8008 8010 8012 8014 8016 8018 8020 8022 7994 7996 8000 8004 8008 8012 8016 8020 0 10 20 30 400-10 SECTION AT STA: 2+12.0 7994 7996 7998 8000 8002 8004 8006 8008 8010 8012 8014 8016 8018 8020 8022 8024 7994 7996 8000 8004 8008 8012 8016 8020 8024 0 10 20 30 40 50 600-10 SECTION AT STA: 2+25.0 7994 7996 7998 8000 8002 8004 8006 8008 8010 8012 8014 8016 8018 8020 8022 7994 7996 8000 8004 8008 8012 8016 8020 0 10 20 300-10 SECTION AT STA: 2+63.9 7992 7994 7996 7998 8000 8002 8004 8006 8008 7992 7996 8000 8004 8008 0 10 20 30 400-10 SECTION AT STA: 3+30.0 7986 7988 7990 7992 7994 7996 7998 8000 8002 8004 8006 7986 7988 7992 7996 8000 8004 0 10 20 300-10-20 SECTION AT STA: 2+39.2 7994 7996 7998 8000 8002 8004 8006 8008 8010 7994 7996 8000 8004 8008 0 10 200-10 PROPOSED TRENCH DRAIN -4.9% -0.8%-12.0% -2.0% TOP BACK OF CURB ELEV = 7998.50 TOP BACK OF CURB ELEV = 7999.74 TOP BACK OF CURB ELEV = 8000.23 TOP OF WALL ELEV = 8006.48 -2.0% -0.6% -2.0% TOP BACK OF CURB ELEV = 7999.56 SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 5' EXISTING GRADE (TYPICAL) PROPOSED GRADE (TYPICAL) TOP BACK OF CURB ELEV = 7998.86 -1.8% -1.1% -2.2% -2.0% -2.0% TOP BACK OF CURB ELEV = 7998.79 TOP BACK OF CURB ELEV = 7998.72 TOP BACK OF CURB ELEV = 7998.39 TOP BACK OF CURB ELEV = 7998.44 TOP BACK OF CURB ELEV = 7997.33 TOP OF WALL ELEV = 7998.00 TOC ELEV = 7994.23 TOP OF WALL (FUTURE LIFT ONE LODGE) ELEV = 7996.00 EXISTING GRADE ELEV = 7994.09 TOP BACK OF CURB ELEV = 7998.59 TOP BACK OF CURB ELEV = 7997.90 -18.1 % -1.0% -2.1% -1.0% -0.6% -1.0% -2.0% -6.3%-2.8% -2.0% -2.0% -2.0% TOP OF STEP ELEV = 7998.55 -2.0% PR O P E R T Y L I N E 0.1% TOP OF WALL ELEV = 8009.27 ENTRANCE TO PARKING GARAGE ELEV = 7999.50 FFE @ MAIN ENTRANCE ELEV = 7999.10 -2.0% LANDSCAPE ISLAND PROPOSED 4.00 DRAIN PAN PROPOSED 4.00 DRAIN PAN PROPOSED 5.00 CROSS WALK PROPOSED 4.00 DRAIN PAN -3.5% UEL UEL ET ET ET ET SAN SAN U E L U E L U E L U E L U E L U E L UE L UE L UE L UE L 8'' SA 8''SA 8''SA 8''SA 8'' SA 8'' SA 8''SA 8''SA SAN TEL TEL TEL > > > > 7990 8000 8010 7992 7994 7996 7998 8002 8004 8006 8008 8012 8014 8016 8016 8016 8018 8 0 0 0 80 0 0 80 0 0 79 9 8 79 9 8 80 0 2 8 0 0 2 8 0 0 2 8 0 1 0 0+ 5 0 1 + 0 0 1 + 5 0 2+00 2 + 5 0 3+00 3+ 5 0 3 + 7 3 EP: 3+72.55 PC: 0+51.30 PC: 1+13.9 7 PC: 3+35.29 PT: 0+97.05 PT: 3+06.34 PCC: 1+58.34 0 + 9 6 . 0 0 0 + 9 6 . 0 0 1+ 5 9 . 0 0 1+ 5 9 . 0 0 1+70. 0 0 1+70.00 2+1 2 . 0 0 2+12.00 2+ 2 5 . 0 0 2+ 2 5 . 0 0 2+ 3 9 . 2 0 2+ 3 9 . 2 0 2 + 6 3 . 8 7 2 + 6 3 . 8 7 3+30.00 3+30.00 1 1 1 1 3 3 3 3 5 5 5 5 - 0 + 0 8 0 + 0 0 7996 7998 SECTION 1 - 1 7988 7992 7996 8000 8004 0 10 200-10-20 SECTION 3 - 3 7988 7992 7996 8000 8004 8008 0 10 200-10-20 SECTION 5 - 5 7986 7988 7992 7996 8000 8004 8008 0 10 200-10-20 SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 10' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 10' SECTION VIEW SCALE: HORZ: 1" = 10' VERT: 1" = 10' TOP OF WALL (FUTURE LIFT ONE LODGE) ELEV = 7995.50 TOP OF WALL ELEV = 7998.00 TOP OF WALL (FUTURE LIFT ONE LODGE) ELEV = 7996.50 TOP OF WALL ELEV = 7998.00 TOP OF WALL (FUTURE LIFT ONE LODGE) ELEV = 7997.50 TOP OF WALL ELEV = 7998.00 -2.0% -3.5% -2.0% -2.0% -2.0% -3.5% -1.6% -1.7% -3.3% PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 20 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 0 2 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 0 - C . 2 . 0 1 C U L - D E - S A C P P & S E C 1 5 1 0 1 . 0 6 . d w g CJB JKS C.2.01 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R CUL-DE-SAC SECTIONS 10-10-2019 SD PRICING PEDESTRIAN RAMP SECTIONSCUL-DE-SAC SECTIONS NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. PROJECT NUMBER:15101.06 1 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW 3-2-20203 DETAILED REVIEW UEL UEL ET ET ET ET ET ET U E L U E L U E L U E L U E L U E L UE L UE L UE L UE L TEL TEL TEL > > > > 7990 8000 8010 7992 7994 7996 7998 8002 8004 8006 8008 8012 8014 8016 8016 8016 8018 8 0 0 0 80 0 0 80 0 0 79 9 8 7 9 9 8 80 0 2 8 0 0 2 8 0 0 2 8 0 1 0 0+ 0 0 0+ 1 0 0+ 2 0 0 + 3 0 0 + 4 0 0 + 5 0 0 + 6 0 0 + 7 0 0 + 8 0 0 + 9 0 1 + 0 0 1 + 1 0 1 + 2 0 1 + 3 0 1 + 4 0 1 + 5 0 1 + 6 0 1 + 7 0 1 + 8 0 1 + 8 3 BP: 0+00.00 PI: 0+26.13 PI: 0+59 . 9 2 PI: 0+69 . 7 5 PC: 1+0 1 . 3 9 PRC : 1 + 4 6 . 6 7 PT: 1+56.38 EP: 1+82.74 0+ 0 0 0+ 1 0 0+ 2 0 0+ 3 0 0+40 0+50 0+60 0+70 0+80 0+9 0 1+0 0 1+1 0 1 + 2 0 1 + 3 0 1 + 3 1 BP: 0+00.00 PI: 0+36.39 PI : 0 + 8 6 . 5 5 PI: 1 + 1 0 . 9 3 EP: 1 + 3 0 . 7 7 - 0 + 0 8 0 + 0 0 7996 7998 PROFILE SCALE: HORZ: 1" = 10' VERT: 1" = 5' EXISTING GRADE PROPOSED GRADE PROPOSED GRADEEXISTING GRADE WEST SIDEWALK PROFILE 7988 7990 7995 8000 8005 8010 8015 8020 PROFILE SCALE: HORZ: 1" = 10' VERT: 1" = 5' EX. -16.0% -16.4% -2.0% -1.4% -1.4% -8.3%-4.5% 0+00 79 8 9 . 4 79 9 3 . 4 0+50 79 9 6 . 9 79 9 7 . 4 4 80 0 0 . 4 79 9 9 . 9 5 1+00 80 0 2 . 4 80 0 0 . 9 8 80 0 8 . 1 80 0 0 . 8 8 1+50 80 1 0 . 5 80 0 0 . 1 1 80 1 5 . 3 79 9 9 . 6 7 1+83 80 1 6 . 7 79 9 9 . 9 1 -8.3% -2.0% 5.00' ADA RAMP @ GARAGE ENTRANCE CROSSING 6.00' ADA WING 6.00' ADA WING -2.9% -4.7% ADA LANDING -4.9%-2.0% ADA LANDING SHADOW MOUNTAIN ACCESS MATCH EXISTING SIDEWALK STA: 0+26.50 ELEV= 7993.68' PROFILE SCALE: HORZ: 1" = 10' VERT: 1" = 5' EXISTING GRADE PROPOSED GRADE PROPOSED GRADEEXISTING GRADE NORTH SIDEWALK PROFILE 7988 7990 7995 8000 8005 -15.3% -2.0% -4.9% -4.9% PROFILE SCALE: HORZ: 1" = 10' VERT: 1" = 5' 0+00 79 8 8 . 7 79 9 2 . 4 79 9 2 . 4 1 0+50 79 9 4 . 7 79 9 4 . 4 0 79 9 5 . 4 79 9 5 . 6 3 1+00 79 9 6 . 9 79 9 6 . 8 6 80 0 2 . 0 79 9 7 . 8 4 1+31 80 0 2 . 5 79 9 7 . 9 8 -2.7% EX. -15.5% MATCH EXISTING SIDEWALK FOR LIFT ONE LODGE STA: 0+05.00 ELEV= 7989.45' ADA LANDING EXISTING SURFACE (SECTION) FINISHED GRADE (SECTION) PROFILE LEGEND 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 20 WEST SIDEWALK ALIGNMENT NORTH SIDEWALK ALIGNMENT 5'X5' LANDING PED. RAMP PED. RAMP DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 0 2 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 0 - C . 2 . 0 1 C U L - D E - S A C P P & S E C 1 5 1 0 1 . 0 6 . d w g CJB JKS C.2.02 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R 10-10-2019 SD PRICING CUL-DE-SAC SIDEWALK PLAN & PROFILE NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. PROJECT NUMBER:15101.06 1 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW FUTURE WALL (NOT PART OF THIS PROJECT) 3-2-20203 DETAILED REVIEW RE. TO SHEET C.2.00 FOR CUL-DE-SAC GRADING S W I T C H G E A R R E C L O S E R X F R M R DS DS DS DS DS DS DS DS DS DS DS DS DS > > > > > > > > > > > > > > > > >>>>>>>>>>>>>>>>>>>> > > > > > > > > >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > > > > > > > > > > > > > > > > > > > > > 8 0 2 0 80 3 0 8 0 4 0 8 0 5 0 8 0 6 0 8 0 7 0 8 0 1 6 8 0 1 6 8 0 1 8 80 2 2 80 2 4 80 2 6 80 2 8 80 3 2 80 3 4 8 0 3 6 8 0 3 8 8 0 4 2 8 0 4 4 8 0 4 6 8 0 4 8 8 0 5 2 8 0 5 4 8 0 5 6 8 0 5 8 8 0 6 2 8 0 6 4 8 0 6 6 8 0 6 8 8 0 7 2 8010 80 1 0 80 2 0 802 0 80 3 0 80 3 0 804 0 804 0 80 5 0 80 5 0 80 6 0 8 0 6 0 80 7 0 8 0 7 0 LEVEL 3 PATIO 8020.5' AREA DRAINS WITHIN PATIO T.B.D. TOC: 8 0 0 9 . 4 8 ' FFE:7999.50' FFE:7999.10' TOW : 8 0 0 6 . 4 2 ' T W : 1 8 . 0 0 T W : 1 8 . 0 0 T W : 2 2 . 0 0 TW: 22.00 T W : 2 2 . 0 0 TW: 22.00 TW: 35.50 TW: 37.00 T W : 3 7 . 5 0 TW: 37.50 TW: 42.50 T W : 4 2 . 5 0 T W : 4 4 . 5 0 T W : 4 4 . 5 0 TW: 44.50 TW : 4 4 . 5 0 TW: 46.50 T W : 4 8 . 5 0 TW: 48.50 TW: 53.50 TW: 53.50 TW: 53.50 TW: 63.00 TW: 73.00 T W : 6 4 . 0 0 TW: 73.00 TW: 13.50 TC: 10.12 T C : 1 0 . 6 8 T C : 1 1 . 0 0 T C : 1 5 . 2 5 TC: 15.75 F G : 1 5 . 4 7 T W : 3 7 . 0 0 FG: 30.00 TC: 41.50 TC: 41.50 TC: 52.00 TC: 52.00 TC: 52.00 TC: 62.00 TC : 0 9 . 0 0 TC: 00.00 FL: 13.60 FL: 10.33 RIM: 07.20 F G : 0 9 . 1 2 F G : 6 5 . 0 0 FG: 20.16 FG: 20.40 FG: 29.00 FG: 34.37 T W : 3 2 . 5 0 FG: 30.50 F G : 3 2 . 9 8 33.7% 31. 7 % 28 . 9 % 26.9 % 26.3% 12.6 % T W : 3 5 . 5 0 TW: 32.50 T W : 3 5 . 5 0 FG: 50.51 LEVEL 3 ENTRANCE = 8020.5' (AREA DRAIN ABOVE STRUCTURE T.B.D.) TW: 22.50 TW: 24.00T W : 2 2 . 5 0 F G : 3 0 . 2 6 6" STEP @ LEVEL 3 STEPS ALONG EDGE OF P A T I O T O ACCOMMODATE SUMM E R G R A D E S FG: 29.50 30" MAX. WALL TC: 99.33 TC: 99.33 TC: 99.50 TC: 99.50 TC: 99.10 TC: 99.10 FFE:7999.10' FFE:7999.25' FFE:7999.10' FFE:7999.10' TW : 0 9 . 5 0 10.6% 10.6%FL: 22.86 FL: 31.55 FL: 32.50 FL: 32.98 F L : 3 3 . 3 1 FL: 39.56 FL: 41.73 F L : 4 5 . 9 6 FL: 49.70 F L : 6 0 . 1 9 FL: 67.02 FL: 69.31 FL: 69.65 FL: 69.70 F L : 6 9 . 4 8 F L : 6 8 . 5 3 FL: 64.68 5. 0 % 2. 0 % 10 . 3 % 33.3 % 33.3% 30.6% 30.6% 30.6% 30.6 % 2.6% 2.6% 16.5%16.5%33.1% TC: 04.00 T C : 0 9 . 2 4 TC: 09.50 TC : 1 7 . 5 0 TC : 0 4 . 0 0 RIM: 03.95 RIM: 08.96 RIM: 17.45 RIM: 23.45 RIM: 33.75 TW: 16.30 T W : 2 0 . 5 0 T W : 2 0 . 5 0 T W : 2 5 . 5 0 TW: 25.50 TW: 26.50 TW : 3 4 . 8 0 TW: 36.50 1.5% 1.1% T W : 1 5 . 5 0 TW: 21.00 TW: 21.00 T W : 2 7 . 0 0 TW: 27.00 TC: 2 3 . 5 0 TC : 3 5 . 5 0 TW : 3 9 . 0 0 TW : 3 6 . 5 0 TC : 2 1 . 0 0 T W : 2 4 . 5 0 TW: 24.50 TW: 28.00 TW: 28.00 T W : 3 6 . 5 0 TW: 36.50T W : 3 6 . 5 0 T W : 3 4 . 0 0 T W : 3 4 . 0 0 T W : 3 4 . 0 0 TW: 34.00 TW: 34.00 TC: 31.00 TC : 3 1 . 0 0 TC : 3 1 . 0 0 RIM: 35.40 RIM: 30.90 RIM: 38.95 RIM: 38.95 RIM: 43.05 RIM: 41.45 RIM: 51.95 RIM: 51.95 RIM: 51.95 RIM: 61.95 RIM: 61.95 RIM: 72.95 RIM: 72.95 TC: 35.50 FG : 1 3 . 0 0 FG : 1 5 . 8 0 FG: 09.98 FG: 15.50 FG : 2 4 . 7 6 FG: 26.00 FG: 33.90 F G : 3 3 . 8 5 FG : 3 3 . 9 0 FG : 3 4 . 0 0 FG : 3 4 . 0 0 FG: 34.50TW: 36.50 TW: 40.00 T W : 4 0 . 0 0 T W : 4 7 . 5 0 T W : 4 7 . 5 0 TW : 4 9 . 5 0 T W : 5 3 . 0 0 T W : 5 3 . 0 0 TW: 53.50 TW: 53.50 TW : 6 0 . 5 0 TW : 6 0 . 5 0 TW : 6 5 . 0 0 TW : 6 5 . 0 0 TW: 73.00 TW: 73.00 T W : 7 3 . 0 0 T W : 7 3 . 0 0 TW: 36.50 TW: 36.50 TW: 36.50 TW: 40.00 TW: 40.00 T W : 4 2 . 5 0 TW : 4 2 . 5 0 TW: 42.50 T W : 4 2 . 5 0 FG: 4 2 . 0 0 T W : 4 7 . 5 0 TW: 47.50 T W : 4 9 . 0 0 TW: 53.00 TW : 5 3 . 0 0 TW : 6 2 . 0 0 TW: 62.00 TW : 7 3 . 0 0 T W : 7 3 . 0 0 T C : 3 5 . 5 0 TC : 3 9 . 0 0 T C : 3 9 . 0 0 TC: 39.00 T C : 4 6 . 5 0 T C : 4 6 . 5 0 T C : 4 8 . 0 0 T C : 5 2 . 0 0 TC: 52.00 TC : 5 2 . 0 0 TC: 31.00 TC: 43.10 TC: 09.24 TC: 41.50 T C : 5 2 . 0 0 T C : 5 2 . 0 0 T C : 5 2 . 0 0 TC : 6 2 . 0 0 TC: 62.00 TC: 73.00 TC: 73.00 FG: 71.00 F G : 7 1 . 0 6 5.0% 7.2% 1 5 . 7 % 7 . 5 % TW : 2 4 . 0 0 TC: 20.50 TC: 3 1 . 0 0 T C : 3 1 . 0 0 TC: 62.00 RIM: 72.95 RIM: 72.95 RIM: 61.95 RIM: 61.95 RIM: 51.95RIM: 51.95 RIM: 51.95RIM: 41.45RIM: 41.45 RIM: 30.95 RIM: 30.95RIM: 30.95 PROPOSED ROOF LINE (TYP.) PROPOSED BUILDING FOOTPRINT AT GRADE (TYP.) LOT 2 LOT 1 LOT 1 S. ASPEN ST. ROW S. ASPEN ST. ROW SHADOW MOUNTAIN SUBDIVISION LOT 1 LOT 2 LEVEL 1 FFE: 7999.1 LEVEL 2 FFE: 8009.5 LEVEL 3 FFE: 8020.5 LEVEL 4 FFE: 8031.0 LEVEL 5 FFE: 8041.5 LEVEL 6 FFE: 8052.0 LEVEL 7 FFE: 8062.5 LEVEL 8 FFE: 8073.0 PROPOSED BELOW GRADE STRUCTURE (TYP.) SETBACK (TYP.) PROPERTY LINE (TYP.) FFE:8009.30'FFE:8009.40' FFE:8021.00' FFE:8031.00'FFE:8031.00' FFE:8031.00' FFE:8043.10' FFE:8052.00' FFE:8052.00'FFE:8052.00' FFE:8062.00'FFE:8062.00' FFE:8073.00' FFE:8073.00' FFE:8041.50' FFE:8067.70' FFE:8062.00' FFE:8062.00' FFE:8052.00' FFE:8052.00' FFE:8052.00' FFE:8041.50'FFE:8041.50' FFE:8031.00'FFE:8031.00' FFE:8031.00' FFE:8020.50' FFE:8020.50' LEVEL 4 PATIO 8031.0' AREA DRAINS WITHIN PATIO T.B.D. LEVEL 4 PATIO LEVEL 5 PATIO LEVEL 5 PATIO LEVEL 6 PATIO LEVEL 6 PATIO LEVEL 6 PATIO LEVEL 7 PATIO LEVEL 7 PATIO LEVEL 8 PATIO LEVEL 8 PATIO LEVEL 7 PATIOLEVEL 7 PATIO LEVEL 6 PATIOLEVEL 6 PATIOLEVEL 6 PATIO PLANTER PLANTER PLANTER LANDSCAPE LANDSCAPE LEVEL 4 PATIO LEVEL 4 PATIO LEVEL 4 PATIO LEVEL 5 PATIO PLANTER PROPOSED ROOF LINE (TYP.) PROPOSED BUILDING FOOTPRINT AT GRADE (TYP.) SETBACK (TYP.) PROPERTY LINE (TYP.) WEST SWALE (RE. TO SHEET C.2.06) FG: 34.42 FG: 37.00 FG: 46.28 FG: 47.00 FG: 52.00 F G : 5 2 . 3 0 FG: 5 7 . 0 0 FG: 59.53 FG: 63.95 FG: 65.00 FG: 67.07 FG: 71.89 FG: 71.40 FG: 7 0 . 5 4 F G : 7 0 . 6 7 FG : 7 1 . 2 0 STAIRS S T A I R S HATCH PATTERN REPRESENTS 1:1 SLOPE AND REQUIRES SLOPE STABILIZATION R E . T O C . 2 . 0 0 F O R P L A Z A & C U L - D E - S A C G R A D I N G TW : 2 4 . 0 0 TW: 40.00 TW: 49.00 FG : 5 1 . 5 0 FG : 5 1 . 5 0 FG: 5 1 . 5 0 RIM: 51.25 RIM: 51.25RIM: 51.25 RIM: 51.95 RIM: 47.95 RIM: 46.45 RIM: 41.75 RIM: 41.25 RIM: 30.25 RIM: 30.95 RIM: 30.95 RIM: 27.25RIM: 20.95 8 0 6 7 . 7 2.0% FG: 71.00 T W : 7 3 . 0 0 RIM: 67.64 TW : 7 3 . 0 0 TC: 7 0 . 6 7 TC : 7 0 . 7 0 TC: 2 0 . 5 0 DRAINAGE DIRECTION/SLOPE SPOT ELEVATION EXAMPLE: TOP OF CONCRETE @ 8000.00' = BW = BOTTOM OF WALL FFE = FINISHED FLOOR ELEVATION FG = FINISHED GRADE FL = FLOW LINE GB = GRADE BREAK HP = HIGH POINT LP = LOW POINT MATCH EX = MATCH EXISTING TC = TOP OF CONCRETE TP = TOP OF PAVERS TW = TOP OF WALL SPOT ELEVATION LEGEND 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 10 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 0 4 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 3 P E R I M E T E R G R A D I N G 1 5 1 0 1 . 0 6 . d w g CJB JKS C.2.03 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R CONCEPTUAL PERIMETER GRADING PLAN NOTES: 1.EXISTING CONTOURS ILLUSTRATED HEREIN ARE AT 2 FT INTERVAL. 2.PROPOSED CONTOURS ARE AT 2 FT INTERVALS. 3.MUDFLOW MITIGATION WALL EXTENDING 2.3' MIN. ABOVE FINAL GRADES REQUIRED ALONG WESTERN SIDE OF BUILDING. 4.PLAN ILLUSTRATES AREA DRAINS @ PATIOS HOWEVER SLOT DRAINS MAY BE UTILIZED INSTEAD. FINAL DETAILS TO BE PROVIDED @ BUILDING PERMIT. 5.AREA DRAINS ABOVE STRUCTURE TO BE DETERMINED (TBD). 6.EROSION CONTROL MATS REQUIRED FOR ALL SLOPES THAT EXCEED 3:1. 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW XX: XX.XX 2.0% TC: 00.00 MA T C H L I N E SE E S H E E T C . 2 . 0 0 NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 3-2-20203 DETAILED REVIEW TC TC TC 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A U E L ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET E T E T E T E T ET ET U E L U E L U E L UEL UEL SW I T C H GE A R RE C L O S E R XF R M R SA N >>>>>>>>>>>>>>>>>>>> > > > > > > > > > > > > > > >>>>>>>>>>>>>>>>>>>>>>>> S A N SA N S A N UEL UEL UEL UEL U E L UEL UEL UEL UEL SA N SA N 8'' SA 8'' SA 8'' SA 8 ' ' S A 8'' SA 8'' SA 8'' SA 8'' SA UEL UE L S A N XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL TE L TE L > > > > > >>>>>>>>>>> > > > > > > > > > > > > TE L TE L T E L TE L > > > > > > > > > > XG A S XG A S XG A S XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XUT XUT XUT x x XSD XSD XSD XEL X E L XEL X E L XE L XE L XE L XE L XE L XU T XUT XU T XUT XG A S XUT XUT XUTXUT XUTX U T XU T XUT X E L X E L X E L X E L X E L XE L XELXEL XEL XEL X E L X E L XEL XEL X E L X E L X E L XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XELXELXELXEL XE L XE L XE L XE L XEL XEL XELXELXELXELXEL XEL XEL XEL XEL XEL XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XG A S XG A S XG A S XG A S XG A S XG A S XGAS XW L XW L XW L XW L XW L XW L XW L XWL XWL XWL XUT XUT XUT XUT XUT XUT XUT XUT X U T X U T X U T X U T XUT XUT XUT XUT XUT XUT XUT XUT XUTXUTXUTXUT X E L XS A XSA XS A X S A XW L XW L XW L XW L XW L XW L XW L XS D XSA XSA X G A S X G A S XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XETC XETC XSD XSD XS D XWL XWL XWL XWLXWL XT V XT V XG A S XT V XGA S 8 0 0 0 8 0 1 0 79 9 2 79 9 4 79 9 6 79 9 8 8 0 0 2 80 0 4 80 0 6 80 0 8 8 0 1 2 80 1 4 80 1 6 8 0 1 8 804 0 80 5 0 800 8 80 1 0 801 4 80 1 6 801 8 8 0 2 0 8022 80 3 0 24.4% 3 2 . 6 % 8 . 5 % 29. 4 % 26 . 3 % 21.7 % 807 0 806 0 804 0 80 5 0 80 8 0 80 9 0 81 0 0 811 0 81 2 0 81 3 0 ?? ? 8 0 0 0 801 0 80 2 0 80 3 0 80 4 0 80 5 0 80 6 0 8070 8080 809 0 8100 81100+ 0 0 0+ 5 0 1+0 0 1+50 2+00 2+50 3+00 3+50 4 + 0 0 4 + 5 0 5+ 0 0 5+50 6+00 6+50 7+00 7+50 7+61 BP: 0+00.00 PC: 0+68.08 P C C : 1 + 1 4 . 3 0 PT : 1 + 6 9 . 6 5 PC : 3 + 4 1 . 2 3 PT: 4 + 1 7 . 1 5 PC: 4 + 7 5 . 6 1 P T : 5 + 7 4 . 0 0 P C : 6 + 1 4 . 2 3 PT : 6 + 2 9 . 1 1 EP : 7 + 6 1 . 4 8 16' PROPOSED GRAVEL ACCESS ROAD PROPOSED AREA INLET PROPOSED AREA INLET EXISTING DRY WELL & ASSOCIATED STORM SYSTEM TO BE ABANDONED PROPOSED STORM MH-D PROPOSED ELECTRIC SPLICE VAULT PROPOSED RE-ALIGNED RUTHIE'S SEWER SERVICE; RE. TO C.3.01 SKI WAY 20' WIDE FIRE ACCESS & DRAINAGE EASEMENT PROPOSED AREA INLET EXISTING MOUNTAIN ROAD MATCH PROPOSED ACCESS TO EXISTING LIFT TOWER #4 LIFT TOWER #6 CABLE GAUGE EDGE-TELEMIX CENTERLINE OF LIFT ALIGNMENT TOWER #5 PROPOSED TELEPHONE PULL VAULT PROPOSED TELEPHONE PULL VAULT PROPOSED SEWER MANHOLE (TYP) SKI WAY PRIMARY ELECTRIC & TELEPHONE REALIGNMENT 20' PRIVATE ACCESS AND UTILITY EASEMENT PROPOSED ELECTRIC SPLICE VAULT UTILITY EASEMENT. RE: TO C3.00 & PLAT MOUNTAIN ROAD PROFILE 7980 7990 8000 8010 8020 8030 8040 8050 8060 8070 8080 8090 8100 8110 8120 7980 7990 8000 8010 8020 8030 8040 8050 8060 8070 8080 8090 8100 8110 8120 0+00 80 0 3 . 7 80 0 3 . 1 0+50 80 0 2 . 4 79 9 7 . 1 1 80 0 1 . 9 79 9 7 . 5 1 1+00 80 0 2 . 8 79 9 9 . 5 6 80 0 2 . 5 80 0 1 . 6 1 1+50 80 0 6 . 7 80 0 3 . 6 6 80 0 9 . 7 80 0 5 . 7 1 2+00 80 1 3 . 0 80 0 7 . 7 9 80 1 4 . 5 80 1 0 . 8 6 2+50 80 1 8 . 0 80 1 5 . 3 8 80 2 2 . 1 80 2 0 . 3 8 3+00 80 2 5 . 9 80 2 5 . 3 8 80 2 9 . 8 80 3 0 . 3 8 3+50 80 3 3 . 0 80 3 5 . 3 8 80 3 8 . 2 80 4 0 . 3 8 4+00 80 4 4 . 8 80 4 5 . 3 8 80 5 2 . 7 80 5 0 . 3 8 4+50 80 6 0 . 8 80 5 5 . 3 8 80 6 7 . 4 80 6 0 . 3 8 5+00 80 7 3 . 6 80 6 5 . 3 8 80 7 9 . 7 80 7 0 . 3 8 5+50 80 8 4 . 2 80 7 5 . 3 8 80 8 7 . 7 80 8 0 . 3 8 6+00 80 9 1 . 4 80 8 5 . 3 8 80 9 4 . 9 80 9 0 . 3 5 6+50 80 9 8 . 8 80 9 5 . 2 9 81 0 2 . 7 81 0 0 . 2 3 7+00 81 0 6 . 7 81 0 5 . 1 7 81 1 0 . 7 81 1 0 . 1 0 7+50 81 1 5 . 1 7+61 81 1 8 . 0 8.20% 20.00% -2.80% 19.75% GR A D E B R E A K S T A = 0 + 4 6 . 3 4 EL E V = 7 9 9 7 . 2 1 GR A D E B R E A K S T A = 7 + 4 8 . 9 1 EL E V = 8 1 1 4 . 8 3 PVI STA: 0+65.00 PVI ELEV: 7996.69 K: 1.36 LVC: 15.00 BV C S : 0 + 5 7 . 5 0 BV C E : 7 9 9 6 . 9 0 EV C S : 0 + 7 2 . 5 0 EV C E : 7 9 9 7 . 3 0 LOW PT. STA: 0+61.32 LOW PT ELEV: 7996.85 PVI STA: 2+20.18 PVI ELEV: 8009.41 K: 4.24 LVC: 50.00 BV C S : 1 + 9 5 . 1 8 BV C E : 8 0 0 7 . 3 6 EV C S : 2 + 4 5 . 1 8 EV C E : 8 0 1 4 . 4 1 PVI STA: 6+15.00 PVI ELEV: 8088.38 K: 220.00 LVC: 55.00 BV C S : 5 + 8 7 . 5 0 BV C E : 8 0 8 2 . 8 8 EV C S : 6 + 4 2 . 5 0 EV C E : 8 0 9 3 . 8 1 SUMMER ACCESS WILL REQUIRE TEMPORARY RAMP NORT H 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 030 30 60 30 12015 SCALE: HORZ: 1"=30' VERT: 1"=30' DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 6 , 2 0 2 0 - 1 0 : 5 0 a m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 4 - C . 2 . 0 5 M N T R D P P & S E C 1 5 1 0 1 . 0 6 . d w g CJB JKS C.2.04 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R MNT. ROAD PLAN, PROFILE & GRADING 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 3-2-20203 DETAILED REVIEW SECTION AT STA: 1+00.0 7988 7992 7996 8000 8004 8008 8012 8016 8020 7988 7992 7996 8000 8004 8008 8012 8016 8020 0 10 200-10-20 SECTION AT STA: 1+25.0 7988 7992 7996 8000 8004 8008 8012 8016 8020 8024 7988 7992 7996 8000 8004 8008 8012 8016 8020 8024 0 10 20 300-10-20-30 SECTION AT STA: 1+50.0 7992 7996 8000 8004 8008 8012 8016 8020 8024 7992 7996 8000 8004 8008 8012 8016 8020 8024 0 10 20 300-10-20-30 SECTION AT STA: 1+75.0 7992 7996 8000 8004 8008 8012 8016 8020 8024 7992 7996 8000 8004 8008 8012 8016 8020 8024 0 10 20 300-10-20-30 SECTION AT STA: 2+00.0 7996 8000 8004 8008 8012 8016 8020 8024 8028 7996 8000 8004 8008 8012 8016 8020 8024 8028 0 10 20 300-10-20-30 SECTION AT STA: 2+25.0 8000 8004 8008 8012 8016 8020 8024 8028 8000 8004 8008 8012 8016 8020 8024 8028 0 10 20 300-10-20-30 SECTION AT STA: 2+50.0 8004 8008 8012 8016 8020 8024 8028 8032 8004 8008 8012 8016 8020 8024 8028 8032 0 10 200-10-20-30-40-50 SECTION AT STA: 2+75.0 8008 8012 8016 8020 8024 8028 8032 8036 8040 8008 8012 8016 8020 8024 8028 8032 8036 8040 0 10 200-10-20-30-40-50 SECTION AT STA: 3+00.0 8008 8012 8016 8020 8024 8028 8032 8036 8040 8044 8008 8012 8016 8020 8024 8028 8032 8036 8040 8044 0 10 20 300-10-20-30-40-50 SECTION AT STA: 3+25.0 8012 8016 8020 8024 8028 8032 8036 8040 8044 8048 8012 8016 8020 8024 8028 8032 8036 8040 8044 8048 0 10 200-10-20-30-40-50 SECTION AT STA: 3+50.0 8016 8020 8024 8028 8032 8036 8040 8044 8048 8052 8016 8020 8024 8028 8032 8036 8040 8044 8048 8052 0 10 20 300-10-20-30-40-50 SECTION AT STA: 4+00.0 8032 8036 8040 8044 8048 8052 8056 8060 8032 8036 8040 8044 8048 8052 8056 8060 0 10 20 300-10 SECTION AT STA: 4+25.0 8036 8040 8044 8048 8052 8056 8060 8064 8036 8040 8044 8048 8052 8056 8060 8064 0 10 20 300-10 SECTION AT STA: 4+50.0 8044 8048 8052 8056 8060 8064 8068 8072 8044 8048 8052 8056 8060 8064 8068 8072 0 10 200-10 SECTION AT STA: 4+75.0 8048 8052 8056 8060 8064 8068 8072 8076 8080 8048 8052 8056 8060 8064 8068 8072 8076 8080 0 100-10-20 SECTION AT STA: 5+00.0 8052 8056 8060 8064 8068 8072 8076 8080 8084 8052 8056 8060 8064 8068 8072 8076 8080 8084 0 10 20 30 40 500-10-20 SECTION AT STA: 5+25.0 8060 8064 8068 8072 8076 8080 8084 8088 8092 8060 8064 8068 8072 8076 8080 8084 8088 8092 0 10 20 300-10-20 SECTION AT STA: 5+50.0 8064 8068 8072 8076 8080 8084 8088 8092 8096 8100 8064 8068 8072 8076 8080 8084 8088 8092 8096 8100 0 10 20 30 400-10-20 SECTION AT STA: 5+75.0 8068 8072 8076 8080 8084 8088 8092 8096 8100 8104 8108 8068 8072 8076 8080 8084 8088 8092 8096 8100 8104 8108 0 10 20 30 40 500-10-20 SECTION AT STA: 6+00.0 8072 8076 8080 8084 8088 8092 8096 8100 8104 8108 8112 8072 8076 8080 8084 8088 8092 8096 8100 8104 8108 8112 0 10 20 30 40 500-10 SECTION AT STA: 6+25.0 8080 8084 8088 8092 8096 8100 8104 8108 8112 8080 8084 8088 8092 8096 8100 8104 8108 8112 0 10 20 30 400-10 SECTION AT STA: 6+50.0 8084 8088 8092 8096 8100 8104 8108 8112 8116 8084 8088 8092 8096 8100 8104 8108 8112 8116 0 10 20 30 400-10 SECTION AT STA: 6+75.0 8088 8092 8096 8100 8104 8108 8112 8116 8120 8124 8128 8088 8092 8096 8100 8104 8108 8112 8116 8120 8124 8128 0 10 20 30 40 500-10 SECTION VIEW SCALE: HORZ: 1" = 20' VERT: 1" = 20' EXISTING GRADE (TYP) PROPOSED GRADE (TYP) 16.00' ROAD (TYP) 1.5' DEEP DITCH WITH 3:1 SIDE SLOPES (TYP) -3.6:1 -2.8:1 -2.4:1 -2.3:1 -2.0:1 -2.0 : 1 -2. 0 : 1 -2. 0 : 1 -2. 0 : 1 -2. 0 : 1 -2.0 : 1 -2.0:1 -2.0 : 1 -2.0:1 -2. 0 : 1 -2.0:1 -2. 0 : 1 -2.0:1 -2. 0 : 1 -2.0:1 -2.0 : 1 -2.0:1 -4.0% 6 ' ' W L 6 ' ' W L E T E T E T E T E T E T E T E T E T E T E T ET ET ET ET ET ET SWITCH GEAR RECLOSER XFRMR > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > 12" 6" debris flow wall top of wall 4-FT MIN. ABOVE GRADE 50-FT LONG TEL TEL TEL TEL >>>>>>>> 6 ' ' W L CON N E C T T O EX. 6" & RE-AL I G N F O R DRY H Y D R A N T 6'' WL 6'' WL 6'' WL XEL XEL XEL XEL XEL XEL XUT X U T XUT X U T XG A S XU T XU T XU T X U T XU T XUT XUT XU T XEL XEL XEL XEL X E L XE L XE L XE L XEL XEL XE L X E L XEL XEL XEL XGA S X G A S XW L X W L XW L XW L XU T XU T XU T XU T XU T XU T XU T XU T XUT XUT XUT XUT XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T X U T XEL XWL XWL XWL XWL XWL XWL X W L X W L X W L X W L XW L 8010 8004 8006 8008 8012 8014 8016 8018 80 4 0 8050 80 0 8 8010 80 1 4 80 1 6 80 1 8 8020 80 2 2 8030 24 . 4 % 32.6% 8.5% 29 . 4 % 26 . 3 % 21 . 7 % 8 0 7 0 8 0 6 0 80 4 0 80 5 0 8090 8100 8 1 1 0 812 0 813 0 EX I S T I N G R O A D CONNECT WITH EXISTING MOUNTAIN ROAD 800 0 8 0 1 0 802 0 803 0 8040 805 0 806 0 8 0 7 0 8 0 8 0 8 0 9 0 8 1 0 0 8 1 1 0 0+00 0+50 1 + 0 0 1 + 5 0 2 + 0 0 2 + 5 0 3 + 0 0 3+ 5 0 4+0 0 4+5 0 5+0 0 5 + 5 0 6 + 0 0 6 + 5 0 7 + 0 0 7 + 5 0 7 + 6 1 B P : 0 + 0 0 . 0 0 P C : 0 + 6 8 . 0 8 PCC: 1 + 1 4 . 3 0 PT: 1+69.65 PC: 3+41.23 P T : 4 + 1 7 . 1 5 P C : 4 + 7 5 . 6 1 PT: 5+7 4 . 0 0 PC: 6+ 1 4 . 2 3 PT: 6+29.11 EP: 7+61.48 1 + 0 0 . 0 0 1 + 0 0 . 0 0 1 + 2 5 . 0 0 1 + 2 5 . 0 0 1 + 5 0 . 0 0 1 + 5 0 . 0 0 1 + 7 5 . 0 0 1 + 7 5 . 0 0 2 + 0 0 . 0 0 2 + 0 0 . 0 0 2 + 2 5 . 0 0 2 + 2 5 . 0 0 2 + 5 0 . 0 0 2 + 5 0 . 0 0 2 + 7 5 . 0 0 2 + 7 5 . 0 0 3 + 0 0 . 0 0 3 + 0 0 . 0 0 3 + 2 5 . 0 0 3 + 2 5 . 0 0 3+ 5 0 . 0 0 3+ 5 0 . 0 0 4+0 0 . 0 0 4+0 0 . 0 0 4+2 5 . 0 0 4+2 5 . 0 0 4+5 0 . 0 0 4+5 0 . 0 0 4+7 5 . 0 0 4+7 5 . 0 0 5+0 0 . 0 0 5+0 0 . 0 0 5+ 2 5 . 0 0 5+ 2 5 . 0 0 5 + 5 0 . 0 0 5 + 5 0 . 0 0 5 + 7 5 . 0 0 5 + 7 5 . 0 0 6 + 0 0 . 0 0 6 + 0 0 . 0 0 6 + 2 5 . 0 0 6 + 2 5 . 0 0 6 + 5 0 . 0 0 6 + 5 0 . 0 0 6 + 7 5 . 0 0 6 + 7 5 . 0 0 7 + 0 0 . 0 0 7 + 0 0 . 0 0 7 + 2 5 . 0 0 7 + 2 5 . 0 0 7 + 4 8 . 0 0 7 + 4 8 . 0 0 EXISTING ROAD CONNECT WITH EXISTING MOUNTAIN ROAD 2 2 ' ± 34.52 2+00 2+ 5 0 PC: 1+13.97 PCC: 1+58.34 1 + 5 9 . 0 0 1+ 7 0 . 0 0 2+12. 0 0 2+12.00 2+2 5 . 0 0 2+2 5 . 0 0 2+ 3 9 . 2 0 2+ 3 9 . 2 0 2 + 6 3 . 8 7 2 + 6 3 . 8 7 PT: 1+56. 3 8 1 + 3 0 1 + 3 1 EP: 1+3 0 . 7 7 3+50 4+00 4+32 3334 34 35 35 36 36 37 37 38 38 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 030 30 60 30 12015 SECTION SCALE: 1" = 20' (VERT. & HORZ) NO R T H DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 0 8 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 4 - C . 2 . 0 5 M N T R D P P & S E C 1 5 1 0 1 . 0 6 . d w g CJB JKS C.2.05 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R MOUNTAIN ROAD SECTIONS 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. NOTES: 1.ALL GRADES EXCEEDING 3:1 SLOPE REQUIRE EROSION CONTROL MAT 2.PROPOSED ROADSIDE SWALE REQUIRES EROSION CONTROL MAT 3-2-20203 DETAILED REVIEW SECTION 2 - 2 7988 7992 7996 8000 8004 8008 8012 8016 8020 8024 8028 0 10 200-10-20 SECTION 3 - 3 7992 7996 8000 8004 8008 8012 8016 8020 8024 8028 0 10 200-10-20 SECTION 4 - 4 7992 7996 8000 8004 8008 8012 8016 8020 8024 8028 8032 0 10 200-10-20 SECTION 5 - 5 8000 8004 8008 8012 8016 8020 8024 8028 8032 0 10 200-10-20 SECTION 6 - 6 8000 8004 8008 8012 8016 8020 8024 8028 8032 0 10 200-10-20 SECTION 7 - 7 8000 8004 8008 8012 8016 8020 8024 8028 8032 0 10 200-10-20 SECTION 8 - 8 8000 8004 8008 8012 8016 8020 8024 8028 8032 8036 0 10 200-10-20 SECTION 9 - 9 8000 8004 8008 8012 8016 8020 8024 8028 8032 8036 0 10 200-10-20 SECTION 10 - 10 8000 8004 8008 8012 8016 8020 8024 8028 8032 8036 0 10 200-10-20 SECTION 11 - 11 8008 8012 8016 8020 8024 8028 8032 8036 8040 0 10 200-10-20 SECTION 12 - 12 8008 8012 8016 8020 8024 8028 8032 8036 8040 0 10 200-10-20 SECTION 13 - 13 8012 8016 8020 8024 8028 8032 8036 8040 0 10 200-10-20 SECTION 14 - 14 8020 8024 8028 8032 8036 8040 8044 8048 0 10 200-10-20 SECTION 15 - 15 8024 8028 8032 8036 8040 8044 8048 8052 8056 8060 0 10 20 300-10-20 SECTION 16 - 16 8020 8024 8028 8032 8036 8040 8044 8048 8052 8056 0 10 200-10-20 SECTION 17 - 17 8020 8024 8028 8032 8036 8040 8044 8048 8052 0 10 200-10-20 SECTION 18 - 18 8024 8028 8032 8036 8040 8044 8048 8052 8056 0 10 200-10-20 SECTION 19 - 19 8028 8032 8036 8040 8044 8048 8052 8056 8060 8064 0 10 200-10-20 SECTION 20 - 20 8028 8032 8036 8040 8044 8048 8052 8056 8060 8064 0 10 200-10-20 SECTION 21 - 21 8032 8036 8040 8044 8048 8052 8056 8060 8064 0 10 200-10 SECTION 22 - 22 8036 8040 8044 8048 8052 8056 8060 8064 8068 0 10 200-10-20 SECTION 23 - 23 8040 8044 8048 8052 8056 8060 8064 8068 0 10 200-10-20 SECTION 24 - 24 8044 8048 8052 8056 8060 8064 8068 8072 8076 0 10 200-10-20 SECTION 25 - 25 8048 8052 8056 8060 8064 8068 8072 8076 0 10 200-10-20 SECTION 26 - 26 8052 8056 8060 8064 8068 8072 8076 8080 0 10 200-10-20 SECTION 27 - 27 8052 8056 8060 8064 8068 8072 8076 8080 8084 0 10 200-10-20 SECTION 28 - 28 8052 8056 8060 8064 8068 8072 8076 8080 8084 0 10 200-10-20 SECTION 29 - 29 8048 8052 8056 8060 8064 8068 8072 8076 8080 8084 8088 0 10 200-10-20 SECTION 30 - 30 8056 8060 8064 8068 8072 8076 8080 8084 0 10 200-10-20 SECTION 31 - 31 8056 8060 8064 8068 8072 8076 8080 8084 0 10 200-10-20 SECTION 32 - 32 8056 8060 8064 8068 8072 8076 8080 8084 0 10 200-10-20 SECTION 1 - 1 7988 7992 7996 8000 8004 8008 8012 8016 8020 8024 8028 0 10 200-10-20 WEST SWALE (TYPICAL) RE. TO NOTES -50.0 % (TYP) -1.0 : 1 -1.0 : 1 -1.0 : 1 -1.0 : 1 -1.0 : 1 2.30' DEPTH (TYPICAL) RE. TO NOTE 3 SECTION 33 - 33 8056 8060 8064 8068 8072 8076 8080 8084 8088 0 10 200-10-20 SECTION 34 - 34 8060 8064 8068 8072 8076 8080 8084 8088 0 10 200-10-20 SECTION 35 - 35 8056 8060 8064 8068 8072 8076 8080 8084 8088 0 10 200-10-20 SECTION 36 - 36 8052 8056 8060 8064 8068 8072 8076 8080 8084 8088 0 10 200-10-20 SECTION 37 - 37 8048 8052 8056 8060 8064 8068 8072 8076 8080 8084 8088 0 10 200-10-20 SECTION 38 - 38 8052 8056 8060 8064 8068 8072 8076 8080 8084 8088 0 10 200-10-20 EROSION CONTROL & SLOPE STABILITY PROTECTION REQ. RE. TO NOTES 8065.5 1. 5 % XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XU T XU T XU T XU T XU T XU T XU T XU T XU T XE L XE L XE L XE L XE L XE L XE L XE L XE L >>> > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >>>>> XGAS XGAS XGAS XGAS XGAS XEL XEL XEL XEL XEL XEL XEL XE L XE L XE L X E L XE L XE L XE L XE L XE L XE L XE L XE L XE L XE L X E L X E L X E L XE L XE L XEL XEL XEL XEL XEL XEL XE L XE L XE L XE L XE L XE L XE L X E L XE L X E L X E L XE L XE L XE L XE L X U T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XU T XGAS XSA XSA XGA S XGA S X G A S XG A S XG A S X G A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S X G A S 8000 8010 8002 8004 8006 8008 8012 8014 8016 8018 50 . 0 % 99.9% -0 + 0 8 0+ 0 0 0+ 5 0 1+ 0 0 1 + 5 0 2 + 0 0 2+ 5 0 3+00 3+50 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 1 6 1 6 1 7 1 7 1 8 1 8 1 9 1 9 2 0 2 0 2 1 2 1 22 22 23 23 24 24 25 25 26 262 7 2 7 2 8 2 8 29 29 30 30 31 31 32 32 33 33 34 34 8010 8020 8 0 3 0 8 0 4 0 8 0 5 0 8 0 6 0 8 0 7 0 8 0 8 0 80 9 0 8004 8006 8008 8012 80 1 4 8016 80 1 6 801 6 8018 8022 80 2 4 8026 8028 80 3 2 80 3 4 8 0 3 6 8 0 3 8 8 0 4 2 80 4 4 8 0 4 6 8 0 4 8 8 0 5 2 8 0 5 4 8 0 5 6 8 0 5 8 8 0 6 2 8 0 6 4 8 0 6 6 8 0 6 8 8 0 7 2 8 0 7 4 8 0 7 6 8 0 7 8 8 0 8 2 8 0 8 4 80 8 6 80 8 8 80 9 2 8 0 9 4 8 0 1 0 8 0 2 0 8 0 3 0 804 0 8 0 5 0 8 0 6 0 8 0 7 0 51.0% 50.3% 51.0% 4. 7 % 17.5 % 31 . 3 % 6 . 2 % 14 . 5 % FG:???' FL:8070.63' RIM:8009.09' 57.9% HATCH PATTERN REPRESENTS 1:1 SLOPE AND REQUIRES SLOPE STABILIZATION WEST SIDE SWALE PROFILE 8005 8010 8020 8030 8040 8050 8060 8070 -0+08 80 1 5 . 5 80 0 7 . 2 0 0+00 80 1 6 . 2 80 0 8 . 0 5 80 1 7 . 1 80 1 0 . 7 0 0+50 80 2 2 . 8 80 1 3 . 3 5 80 2 5 . 3 80 2 1 . 0 9 1+00 80 2 9 . 5 80 2 6 . 1 1 80 3 5 . 1 80 3 0 . 2 4 1+50 80 4 1 . 9 80 3 2 . 8 0 80 4 6 . 8 80 3 5 . 0 5 2+00 80 5 2 . 0 80 4 2 . 7 1 80 5 7 . 2 80 5 0 . 4 3 2+50 80 6 3 . 1 80 5 8 . 7 6 80 6 7 . 7 80 6 6 . 7 8 3+00 80 6 9 . 8 80 6 9 . 3 2 80 7 1 . 6 80 6 9 . 5 2 -33.1% -16.5% -2.6% -30.6% -10.3%-2.0% 18" DEEP SWALE WITH 12" WIDE BOTTOM AND 3:1 (MAX) SIDE SLOPES. INSTALL SCOUR STOP OR APPROVED EQUAL ALONG FLOWLINE OF SWALE FOR EROSION PROTECTION. (TYPICAL) -33.3% -10.6% FLOWLINE OF WEST SWALE; REFER TO NOTES ON THIS SHEET 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 20 8010 SECTION SCALE: 1" = 20' (VERT. & HORZ) NO R T H DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 1 1 : 4 1 a m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 6 W E S T S W A L E P P & S E C 1 5 1 0 1 . 0 6 . d w g CJB JKS C.2.06 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R WEST SWALE PLAN, PROFILE & SECTIONS PROFILE SCALE: 1" = 20' (VERT. & HORZ) 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTES: 1.MINIMUM DIMENSIONS OF SWALE:18" DEEP, 3:1 SIDE SLOPES, 12" WIDE BOTTOM 2.EROSION CONTROL MAT REQUIRED ALONG FLOWLINE AND SIDE SLOPES OF SWALE. 3.2.3' MIN. DEPTH REQUIRED ALONG ENTIRE WEST SIDE MEASURED FROM FLOWLINE TO PATIO/TOP OF WALL PER DEBRIS FLOW MITIGATION RECOMMENDATIONS. 4.EROSION CONTROL MATS REQUIRED FOR ALL SLOPES THAT EXCEED 3:1. NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 3-2-20203 DETAILED REVIEW >>>>>>>>>>> > > > > >>>>>>>> > > > > > > > > > >>>>>>>>>>>>>>>>>>>>>>> > > > > > > > > >>>>>>> > > >>>>>>>>>>>>>>>> > > > > > > > > > > x 8 0 0 0 8 0 1 0 8 0 2 0 80 3 0 8 0 4 0 8 0 5 0 8 0 6 0 8 0 7 0 808 0 7 9 9 2 79 9 4 79 9 6 7 9 9 8 8 0 0 2 8 0 0 4 8 0 0 6 8 0 0 8 8 0 1 2 8 0 1 4 8 0 1 6 8 0 1 6 8 0 1 6 8 0 1 8 80 2 2 80 2 4 80 2 6 80 2 8 80 3 2 80 3 4 8 0 3 6 8 0 3 8 8 0 4 2 8 0 4 4 8 0 4 6 8 0 4 8 8 0 5 2 8 0 5 4 8 0 5 6 8 0 5 8 8 0 6 2 8 0 6 4 8 0 6 6 8 0 6 8 8 0 7 2 8 0 7 4 8 0 7 6 8 0 7 8 808 2 80 8 4 80 8 6 808 8 8000 80 0 0 8000 7998 799 8 800 2 8002 8002 80 0 0 801 0 80 2 0 80 3 0 8 0 4 0 80 5 0 80 6 0 80 7 0 80 8 0 80 9 0 810 0 811 0 8 1 2 0 8010 80 1 0 80 2 0 8020 8030 80 3 0 804 0 804 0 80 5 0 80 5 0 80 6 0 8 0 6 0 80 7 0 8 0 7 0 LEVEL 4 PATIO LEVEL 5 PATIO LEVEL 5 PATIO LEVEL 6 PATIO LEVEL 6 PATIO LEVEL 6 PATIO LEVEL 7 PATIO LEVEL 7 PATIO LEVEL 8 PATIO LEVEL 8 PATIO LEVEL 7 PATIOLEVEL 7 PATIO LEVEL 6 PATIOLEVEL 6 PATIOLEVEL 6 PATIO PLANTER PLANTER PLANTER LANDSCAPE LEVEL 4 PATIO LEVEL 4 PATIOLEVEL 4 PATIO LEVEL 5 PATIO PLANTER PROPOSED ROOF LINE (TYP.) PROPOSED BUILDING (TYP.) WEST SWALE (RE. TO SHEET C.2.06) STAIRS ST A I R S LOT 2 LOT 1 LOT 1 S. ASPEN ST. ROW MOUN T A I N Q U E E N LOT 2 LI F T O N E L O D G E - L O T O N E LI F T O N E LO D G E - L O T T W O LI F T O N E LO D G E - L O T T H R E E S. ASPEN ST. ROW SHADOW MOUNTAIN SUBDIVISION BA R B E E F A M I L Y CO N S E R V A T I O N P A R C E L SH A D O W M O U N T A I N SU B D I V I S I O N LOT 1 LOT 2 SOUTH ASPEN STREET SUBDIVISION SHADOW MOUNTAIN VILLAGE HI L L S T R E E T RO W HI L L S T R E E T R O W LEVEL 1 FFE: 7999.1 LEVEL 2 FFE: 8009.5 LEVEL 3 FFE: 8020.5 LEVEL 4 FFE: 8031.0 LEVEL 5 FFE: 8041.5 LEVEL 6 FFE: 8052.0 LEVEL 7 FFE: 8062.5 LEVEL 8 FFE: 8073.0 HI L L S T R E E T R O W MOUNT A I N Q U E E N PIONEER GULCH WEST SWALE DEBRIS FLOW PATH & DEPTH MEASUREMENT FROM FLOWLINE OF SWALE; RE. TO C.2.06 FOR SWALE SECTIONS *APPROXIMATE WESTERN SOURCE OF DEBRIS FLOW * APPROXIMATE EASTERN SOURCE OF DEBRIS FLOW TW: 36.50 TW: 26.66TW: 16.26TW: 09.64 TW: 40.00 TW: 46.50 TW: 53.50 TW: 73.00 TC: 35.49 FL: 33.19 FL: 32.52 FL: 23.65 FL: 13.54 FL: 07.21 FL: 66.67 FL: 49.97 FL: 40.60 DEBRIS FLOW WALL (BY OTHERS) APPROXIMATE MUDFLOW PATH SPOT ELEVATION EXAMPLE: TOP OF CONCRETE @ 7900.00' = FL = FLOW LINE TC = TOP OF CONCRETE TW = TOP OF WALL SPOT ELEVATION LEGEND 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 30 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 0 9 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 2 . 0 7 M u d f l o w M i t i g a t i o n P l a n . d w g CJB JKS C.2.07 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R MUDFLOW MITIGATION PLAN NOTES: 1.EXISTING CONTOURS ILLUSTRATED HEREIN ARE AT 2 FT INTERVAL. 2.PROPOSED CONTOURS ARE AT 2 FT INTERVALS. 3.REFER TO GORSUCH HAUS MUDFLOW ANALYSIS DATED JANUARY 14, 2020 4.MUDFLOW MITIGATION WALL EXTENDING 2.3' MIN. ABOVE FINAL GRADES (MEASURED FROM FLOWLINE OF WEST SWALE) REQUIRED ALONG WESTERN SIDE OF BUILDING. NO MITIGATION REQUIREMENTS ALONG EAST SIDE OF PROPOSED BUILDING 5.UNDER THE INTERIM CONDITION (GORSUCH PROJECT WITHOUT LIFT ONE LODGE MOVING FORWARD), A DEBRIS FLOW WALL WILL BE REQUIRED AT THE EASTERN SIDE OF HILL STREET ROW AS ILLUSTRATED HEREIN. 6.OPENINGS (PRIMARILY DOORS & WINDOWS) SHALL BE PLACED 3 FEET ABOVE THE MUDFLOW ELEVATION FOR ALL WALLS THAT WILL HAVE DIRECT IMPACT FORCES FROM MUDFLOW AND DEBRIS AND 2 FEET ABOVE THE MUDFLOW ELEVATIONS FOR ALL WALLS IMPACTED BY MUDFLOWS MOVING LATERALLY OR ARE IN THE SHADOW OF TEH UP-FAN BUILDINGS. PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW XX: XX.XX TC: 00.00 3-2-20203 DETAILED REVIEW WL SVC WL SVC TC TC TC 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16'' WL 16'' WL 16'' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 6''WL 6''WL 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8'' S A 8'' S A 8'' S A 8'' S A 8'' S A 8'' S A 8'' S A 8'' S A U E L ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET U E L U E L U E L UEL UEL GA S GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS G A S G A S G A S GAS GAS GAS G A S G A S G A S G A S G A S GA S GA S GA S GA S GA S GAS GAS GAS S W I T C H G E A R R E C L O S E R X F R M R S A N S A N S A N S A N GAS GA S GAS GAS GAS GAS GAS UEL UEL UEL UEL UE L UEL UEL UEL UEL S A N S A N 8'' SA 8' ' SA 8 ' ' S A 8'' SA 8 ' ' SA 8 ' ' SA 8'' SA 8'' SA UEL UE L S A N XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL T E L TE L T E L T E L T E L T E L 6'' WL 6''WL 6' ' WL 6' ' WL 6' ' WL XG A S XG A S XG A S MONARCH STREET S. ASPEN STREET SHADOW MOUNTAIN VILLAGE MOUN T A I N Q U E E N PROPOSED LIFT ONE LODGE XEL XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XGAS XGAS XEL XEL XEL uc ucuc XE L XE LXEL XELXTV uu XT V XU T XUT XUT XUT XUT XUT XUT XUT XSD XSD XSD XEL XE L XEL X E L X E L X E L X E L XE L XE L XU T XUT XU T XU T XGAS XUT XUT XUT XUTXUT X U T X U T XUT XEL XEL XE L XE L X E L X E L XEL XELXELXELXEL XEL XEL XEL X E L X E L X E L XEL XEL XEL XELXELXEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XE L XE L XE L XE L XEL XEL XEL XEL XEL XEL XEL XELXEL XEL XELXELXEL XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XU T XU T XG A S XG A S XG A S XG A S XG A S XG A S XGAS XG A S XE L XE L XW L XW L XW L XW L XW L XW L XW L XW L XWL XWL XUTXUTXUTXUTXUTXUTXUTXUTX U T X U T XU T X U T XUT XUTXUTXUTXUTXUTXUTXUTXUT XUT XUT XUT XEL XU T XU T X E L XS A XSA XS A X S A XGAS XGAS XGAS XGAS XGAS XGAS XGAS XG A S X G A S X G A S X G A S XG A S XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XWL XTV XTV X T V X U T X U T XT V XT V XUT XUT XUT XUT XUT XUT XUT X U T X U T XUT XUT XUT XUTXUTXUTXUTXUTXUT XU T XU T XU T XT V XE L XEL XEL XEL XEL XE L XELXELXELXELXELXELXELXELXEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XTV XTVXTV XTV XTVXTVXTVXTVXTVXTVXTV XT V XT V XU T XUT X S D XSD XSD XSD XSD XSD XSD XSD XSD XSA XSA XSA XSA XSA XSA XSA XWL XWL XWL XWL XWL XGAS X G A S XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGASXETCXETCXETCXETCXETCXETC XSD XSD XSA XSA XSA XSA XSA XS D XWL XWL XWL XWL XWL XWLXWLXWLXWLXWLXWL XWLXWLXWLXWLXWLXWLXWL XT V XT V XUT XUT XUT XSD XUT XG A S XT V XUT XUT XUT XGASXGASXGASXGAS PROPOSED 20.0' ACCESS & UTILITY EASEMENT RE: TO PLAT 6.5' PROPOSED UTILITY ESMNT. 30' WATER EASEMENT PROPOSE D U T I L I T Y EASEME N T RE. TO PL A T S. MONARCH SU M M I T LOCATION OF EX. TRANSFORMER 3130 P2 EXISTING SWITCH GEAR AND RECLOSER TO BE RELOCATED AS ILLUSTRATED HEREIN EXISTING SPLICE VAULT TO BE ABANDONED LOCATION OF RECENTLY INSTALLED SPLICE VAULT RE-ROUTE PRIMARY FEEDS FROM THIS LOCATION AS ILLUSTRATED HEREIN PROPOSED PRIMARY ELECTRIC & TELE. RE-ALIGNMENT PROPOSED INTERMEDIATE SPLICE VAULT FOR ELEC. PRIMARY RE-ROUTE EXISTING TRANSFORMER (3128 P1) SERVING SHADOW MOUNTAIN TOWNHOMES TO BE ABANDONED UPON THE COMPLETION OF RE-ESTABLISHING SECONDARY ELECTRIC SERVICE FROM THE TRANSFORMER (3130 P2) LOCATED AT SOUTHEAST CORNER OF S. ASPEN STREET SUBDIVISION. THE NEW SECONDARY FEEDS WILL BE WORKED DIRECTLY INTO THE EXISTING MDP PANEL OR MAY NEED TO BE SPLICED IN AN IN-GRADE ELECTRICAL BOX ADJACENT TO THE 3128 TRANSFORMER. RE. TO BLOWUP OF PROPOSED UTILITY LAYOUT; THIS SHEET PROPOSED LIFT ALIGNMENT EXISTING ELECTRIC SWITCH GEAR TO BE RELOCATED TO EAST SIDE OF BUILDING AS ILLUSTRATED HEREIN EXISTING SECONDARY UTILITY FEEDS TO BE ABANDONED UPON COMPLETION OF RELOCATION PROPOSED RE-ALIGNMENT OF EXISTING PRIMARY ELECTRIC FEED PROPOSED 6" WATER SERVICE (RE. TO C.3.02. FINAL SIZE TO BE CONFIRMED AT TIME OF BUILDING PERMIT) PROPOSED 8" SEWER SERVICE; (RE. TO C.3.02) PROPOSED RE-ALIGNMENT OF RUTHIE'S SEWER 8" SEWER SERVICE; RE. TO SHT C.3.01 FOR PROFILE PROPOSED 16" WATER MAIN ALIGNMENT; RE. TO SHT C.3.03 & C.3.04 FOR PLAN & PROFILE PROPOSED OFFSITE STORM SYSTEM RE. TO C.4.05 PROPOSED GAS RE-ALIGNMENT PROPOSED CABLE & TELE SERVICE ALIGNMENT APPROX. LOCATION TO INTERCEPT EXISTING 8" RUTHIE'S SANITARY SEWER SERVICE AND RE-ALIGN PROPOSED STORMWATER TREATMENT VAULT #1 FOOTPRINT OF BELOW GRADE STRUCTURE LOCATE AND RE-ROUTE EXISTING GAS SERVICE TO SHADOW MOUNTAIN TOWNHOMES (RE-ESTABLISHED ALIGNMENT MAY REQUIRE DIRECTIONAL BORING TO MINIMIZE IMPACTS TO EXISTING TREES) CONNECT TO EXISTING SEWER MAIN WITH 4' DIA. MANHOLE AND SOLID SLEEVE CONNECTION TO EXISTING LINES PROPOSED DRY HYDRANT LOCATION PROPOSED DRY HYDRANT LOCATION EXISTING HYDRANT LOCATION PROPOSED 6" DRY HYDRANT LINE TO BE USED AS DRY HYDRANT FEEDER FOR MT. QUEEN. DRAIN LINE TO BE ROUTED TO PROPOSED MANHOLE; RE. TO C.3.03 EXTEND EXISTING WATER LINE TO PROPOSED TERMINUS DRY HYDRANT PROPOSED FIRE HYDRANT PROPOSED SANITARY SEWER SERVICE 2-WAY CLEANOUT EXISTING PRIMARY & SECONDARY UTILITY FEEDS TO BE ABANDONED UPON COMPLETION OF RELOCATION SCREEN WALLS WITH REMOVABLE GRATE ABOVE SETBACK LINE (TYP) EXISTING TRANSFORMER 3128P2 LOCATION, DEPTH AND SIZES OF EXISTING TELEPHONE & GAS MAINS TO BE CONFIRMED IN THE FIELD PRIOR TO CONSTRUCTION PROPOSED SUBSURFACE SPLICE VAULT PROPOSED TELE. SPLICE/PULL VAULT PROPOSED TELE. PULL VAULT RE-CONNECT MT. QUEEN WATER SERVICE PROPOSED WATER TREATMENT VAULT SECONDARY ELECTRIC SERVICE TO RE-ESTABLISH SERVICE TO SHADOW MOUNTAIN TOWNHOMES (3) 3-INCH RACE WAY. (FINAL ALIGNMENT TO BE DETERMINED & MAY REQUIRE DIRECTIONAL BORING TO MINIMIZE IMPACTS TO EXISTING TREES) CONNECT RE-ROUTE ELECTRIC PRIMARY TO EXISTING ELEC. SPLICE VAULT. LOCATION OF EX. VAULT TO BE CONFIRMED IN THE FIELD PRIOR TO CONSTRUCTION S W I T C H G E A R R E C L O S E R X F R M R U E L U E L U E L UELUELUELUELUELUEL U E L U E L UEL U E L UEL UEL UEL FG: 09.76 T W : 1 8 . 0 0 T W : 1 8 . 0 0 T W : 2 2 . 0 0 T W : 2 2 . 0 0 TW: 22.00 F G : 0 9 . 9 2 F G : 1 0 . 2 3 T C : 1 1 . 0 0 T C : 1 5 . 2 5 T C : 1 5 . 7 5 F G : 1 3 . 9 2 F G : 1 4 . 3 6 FG: 14.74 FG: 20.15 FG: 14.74 PROPOSED RELOCATED SWITCH GEAR; FRONT DOORS FACING NORTH & REAR DOORS FACING SOUTH; SITS ON 8'x7' VAULT SCREEN WALLS WITH REMOVABLE GRATE ABOVE PROPOSED RELOCATED RECLOSER W/ DOORS ORIENTED TO THE EAST; SITS ON 7'x7' VAULT PROPOSED 1500KVA 3-PHASE TRANSFORMER FOR PROJECT DOORS ORIENTED TO THE EAST SITS ON 7'x7' VAULT PROPOSED EDGE OF BUILDING 5.5' SWITCH GEAR DIM. 10.0' MIN. 4.0' MIN. 4.0' MIN. 4.0' MIN. 10.0' MIN. 4.0' MIN. 4.0' MIN.4.0' MIN. FG: 10.39 T W : 1 8 . 0 0 T W : 1 8 . 0 0 T W : 2 2 . 0 0 F G : 1 4 . 9 6 F G : 1 5 . 4 9 F G : 1 1 . 0 8 T W : 1 8 . 0 0 T W : 2 2 . 0 0 TW: 22.00 F G : 1 0 . 0 2 F G : 1 0 . 1 4 F G : 1 0 . 5 1 F G : 1 0 . 2 2 F G : 1 4 . 0 9 F G : 1 4 . 6 3 F G : 1 5 . 0 0 F G : 1 5 . 0 1 F G : 1 4 . 4 5 F G : 1 4 . 5 3 F G : 1 4 . 8 5 F G : 1 5 . 2 1 F G : 0 9 . 4 6 F G : 0 6 . 9 6 F G : 0 6 . 2 2 PROPOSED GATES AT OPENING. GATES TO OPEN COMPLETELY SO NOT TO INHIBIT FUTURE ACCESS PROPOSED GATES AT OPENING. GATES TO OPEN COMPLETELY SO NOT TO INHIBIT FUTURE ACCESS PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE6''WL 16'' WL PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UE FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING LIGHT POLE EXISTING SIGN EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING ELEC, TELE, CABLE, GASXETGC EXISTING GAS XETC XETC EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE EXISTING ELEC, TELE, CABLE XUT XUT XEL XEL XTV XTV XSA XSA NORTH XSD XSD 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 030 30 60 30 12015 LEGEND: PROPOSED UTILITIES ELECTRIC VAULT LAYOUT DETAIL SCALE: 1" = 5' SAN DRY WELL LEGEND: EXISTING UTILITIES DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS 15101.06 GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 1 2 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 3 . 0 0 - C . 3 . 0 2 M A S T E R U T I L I T Y 1 5 1 0 1 . 0 6 . d w g CJB JKS C.3.00 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R MASTER CONCEPTUAL UTILITY PLAN 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 1.ALL MINIMUM DEPTHS, SEPARATION DISTANCES, MATERIALS AND/OR USE OF CONDUIT SHALL BE CONFIRMED AND COORDINATED WITH THE UTILITY PROVIDER PER UTILITY AGREEMENTS. 2.ALL UTILITY LINES AND/OR CONDUITS TO BE BACKFILLED WITH SUITABLE MATERIAL FREE OF ROCKS >1 1/2" Ø. USE CLASS 6 AGGREGATE BASE MATERIAL FOR BEDDING, AND/OR SUITABLE ONSITE MATERIAL. INSTALL PER UTILITY PROVIDER SPECIFICATIONS. BACKFILL TRENCHES WITH SUITABLE ONSITE MATERIALS. MINIMUM COMPACTION 95% IN PAVED AREAS. 3.GAS AND ELECTRIC TO BE INSTALLED IN SEPARATE TRENCHES. SEWER SERVICES TO BE INSTALLED A MINIMUM 10' FROM WATER SERVICES AS FEASIBLE. COMMUNICATIONS MAY BE INSTALLED IN COMBINED TRENCHES PER CONSTRUCTION FEASIBILITY AS LONG AS MINIMUM SEPARATION DISTANCES AND DEPTHS OF BURY ARE MAINTAINED. INSTALL WARNING TAPE OVER ALL UTILITY LINES. UTILITY SERVICE MINIMUM DEPTH WATER--------------------------------7.0' SEWER--------------------------------5.0' ELECTRIC----------------------------4.0' CABLE TV----------------------------3.0' PHONE--------------------------------3.0' GAS----------------------------------- 3.0' 1.CONTRACTOR TO COORDINATE ABANDONMENT, RELOCATION, AND BURIAL OF THE EXISTING UTILITIES WITH THE UTILITY PROVIDERS. CONTRACTOR TO PROVIDE ALL TRENCHING, BEDDING, AND BACKFILL WORK NECESSARY FOR UTILITY RELOCATION. 2.THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION OPERATIONS WITHIN THE LIMITS OF CONSTRUCTION. CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR CONSENT OF THE PROPERTY OWNER(S) INVOLVED. 3.THE LOCATIONS OF UNDERGROUND UTILITIES HAVE BEEN PLOTTED BASED ON UTILITY MAPS, LOCATES OR OTHER INFORMATION PROVIDED BY UTILITY COMPANIES AND ACTUAL FIELD LOCATIONS IN SOME INSTANCES. THESE UTILITIES, AS SHOWN MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATION OF UTILITIES PRIOR TO CONSTRUCTION. 4.CONTRACTOR TO COORDINATE ALL UTILITY LINEWORK WITH THE RESPECTIVE UTILITY COMPANY PRIOR TO CONSTRUCTION. GENERAL UTILITY NOTES:SHALLOW UTILITY NOTES: NOTES: 1.POWER TO THE RECLOSER WILL BE SUPPLIED FROM THE PROJECT TRANSFORMER; 2.AN ANTENNA WILL BE REQUIRED FOR THE SWITCH GEAR AND RECLOSER TO COMMUNICATE WITH THE EXISTING RECEIVER THAT IS LOCATED FURTHER UP MOUNTAIN ROAD ("KLEENEX CORNER"). A CLEAR LINE OF SIGHT WILL BE NEEDED BETWEEN THE ANTENNA AND EXISTING RECEIVER. LOCATION OF ANTENNA TO BE COORDINATED AND CONFIRMED WITH HOLY CROSS ENERGY PRIOR TO BUILDING PERMIT APPLICATION; 3-2-20203 DETAILED REVIEW WL SVC WL SVC WL SVC TC TC TC TC TC 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL U E L U E L ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET UEL U E L U E L U E L U E L GA S GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GA S G A S G A S G A S GAS GAS GAS GAS GAS G A S G A S G A S G A S G A S GA S G A S GA S GA S GA S GA S GA S GA S GA S GA S GAS GAS GAS GAS S W I T C H G E A R R E C L O S E R X F R M R S A N > > > > > >>>>>>>>>>> > > > > > > > > > > > > > > >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > > > > > S A N S A N S A N GAS GAS GA S GAS GAS GAS GAS GAS GAS GAS G A S UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL S A N S A N 4'' WL UELUE L U E L S A N XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL T E L TE L TE L > > > > > > > > >>>>>>>>>> > > > > >>>>>>>>>>>>>>>>>>>>>>> T E L T E L T E L T E L T E L T E L T E L TEL > > > > > > > > > > > > > > > 6'' WL 6''WL 6''WL 6''WL 6' ' WL 6' ' WL 6' ' WL 6' ' WL XG A S XG A S XG A S XG A S XG A S 0+ 0 0 0 + 5 0 1 + 0 0 1 + 1 0 0 + 0 0 0 + 5 0 1 + 0 0 1+5 0 2+0 0 2+50 3+00 3+50 4+00 4+ 5 0 5+ 0 0 5+ 5 0 6+ 0 0 6 + 5 0 6+85 80 6 0 80 5 0 80 2 8 80 0 0 80 7 0 80 0 0 8 0 3 0 80 4 0 8 0 5 0 8 0 6 0 8 0 7 0 8 0 8 0 37 . 5 ' o f 8 " S D R - 2 6 @ 2 . 0 0 % 63.0' of 8" SDR-26 @ 2.00% 42.5' of 8" SDR-26 @ 2.00% 83.1' of 8" SDR-26 @ 2.00% 84.2' of 8" SDR-26 @ 7.21% 209.2' o f 8 " S D R - 2 6 @ 1 7 . 5 0 % 2 4 5 . 0 ' o f 8 " S D R - 2 6 @ 2 0 . 0 0 % XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA X E L X E L XUT XUT XSD XSD XSD XSD XSD XEL XE L XELXEL X E L X E L X E L X E L XE L X E L XE L XE L XE L XU T XU T XU T XUT XU T XU T XU T XUT XGAS XGAS XUT XUT XUT XUT XUT XUTXUT XU T X U T XUT XUTXUT XEL XEL XEL XE L XE L XE L X E L X E L X E LXEL XEL XELXELXELXELXELXEL XEL XELXEL XEL XEL X E L X E L X E L X E L X E L XEL XEL XEL XEL XEL XELXELXEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XE L XE L XE L XE L XE L XE L XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XELXELXEL XEL XELXELXELXEL XU T XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XGAS XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XWL XWL XWL XUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUT X U T X U T X U T XU T X U T X U T XUT XUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUT XUT XUT XUT XUT X G A S XEL X E L XS A XSA X S A XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XSD XSD XSD XSD XSA XSA XSA XSA XWL XW L XGAS X G A S X G A S XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGA S XETC XETC XETC XSD XSD XSD XS D XS D XWL XWL XWL XWL XWL XWL XWL XT V XT V XUT XUT XT V XUT XUT XGASXGAS XE L STA:0+99.25 PROPOSED UTILITY XING STA:0+18.62 PROPOSED UTILITY XING STA:0+71.02 PROPOSED UTILITY XING STA:1+16.91 PROPOSED UTILITY XING STA:1+25.75 PROPOSED UTILITY XING STA:1+49.33 PROPOSED UTILITY XING STA:2+60.10 PRPOPOSED UTILITY XING STA:0+54.72 PROPOSED UTILITY XING STA:4+50.56 PRPOPOSED UTILITY XING STA:0+61.93 PROPOSED UTILITY XING PROPOSED 4'Ø MH-6 STA:0+00.00 (SEWER SERVICE) RIM:7999.96 EX. 8" INV. IN(SE):7993.91 EX. 8" INV. IN(SE):7988.01 EX. 8" INV. IN(W):7994.48 EX. 8" INV. IN(W):7987.98 PROPOSED 8" SDR-26 INV IN:7987.86 EX. 8" INV. OUT(N):7987.66 PROPOSED 4'Ø MH-7 STA: 0+00 (RUTHIES SEWER SERVICE) STA:0+41.50 (SEWER SERVICE) RIM:8002.27 8" SDR-26 INV IN:7988.81 8" SDR-26 INV IN:7988.81 8" SDR-26 INV OUT:7988.61 2-WAY CLEANOUT W/ FRAME & GRATE STA:1+06.50 RIM:7990.80 8" SDR-26 INV IN:7990.07 8" SDR-26 INV OUT:7990.07 PROPOSED 4'Ø MH-8 STA:0+46.50 RIM:7997.70 8" SDR-26 INV IN:7989.86 8" SDR-26 INV OUT:7989.66 PROPOSED 4'Ø MH-9 STA:1+33.59 RIM:7998.41 8" SDR-26 INV IN:7991.72 8" SDR-26 INV OUT:7991.52 PROPOSED 4'Ø MH-10 STA:2+21.50 RIM:8005.43 8" SDR-26 INV IN:7997.97 8" SDR-26 INV OUT:7997.77 PROPOSED 4'Ø MH-11 STA:4+31.48 RIM:8041.40 8" SDR-26 INV IN:8034.21 8" SDR-26 INV OUT:8034.01 PROPOSED 4'Ø MH-12 STA:6+75.55 RIM:8094.86 EX. 8" INV. IN(S):8091.43 8" SDR-35 INV OUT:8082.22 STA:1+18.49 PROPOSED UTILITY XING STA:2+04.03 PROPOSED UTILITY XING STA:4+39.71 PRPOPOSED UTILITY XING STA:4+21.54 PRPOPOSED UTILITY XING 7980 7990 8000 8010 8020 8030 0+00 80 0 3 . 2 80 0 2 . 2 7 80 0 3 . 4 79 9 9 . 5 6 0+50 80 0 2 . 6 79 9 7 . 6 4 80 0 2 . 6 79 9 8 . 1 1 1+00 80 0 1 . 8 79 9 7 . 1 2 80 0 1 . 2 79 9 7 . 7 1 1+50 80 0 4 . 3 79 9 8 . 9 7 8" INV: 7991.41' 8" SEWER INV: 7989.14' 6" WATER SVC. STA: 0+18.62 INV.= 7991.39' 10" PVC STORM STA: 0+71.02 INV.= 7988.73' 8" SEWER INV: 7990.31' 18" STORM STA: 1+25.75 INV= 7988.10' 10" PVC STORM STA: 1+18.49 INV= 7987.82' 8" INV: 7991.26' PROPOSED 4'Ø MH-7 STA:0+00.00 RIM:8002.27 8" SDR-26 INV IN:7988.81 8" SDR-26 INV IN:7988.81 8" SDR-26 INV OUT:7988.61 42.5' of 8" SDR-26 @ 2.00% PROPOSED 4'Ø MH-8 STA:0+46.50 RIM:7997.70 8" SDR-26 INV IN:7989.86 8" SDR-26 INV OUT:7989.66 83.1' of 8" SDR-26 @ 2.00% PROPOSED 4'Ø MH-9 STA:1+33.59 RIM:7998.41 8" SDR-26 INV IN:7991.72 8" SDR-26 INV OUT:7991.52 1.58 1.58 2.59 1.77 1+16.91 PROPOSED GAS T.O.P.=7994.28' SCALE: HORZ. 1" = 20' VERT. 1" = 20' RUTHIES SEWER SERVICE PROFILE 7980 7990 8000 8010 8020 8030 8040 8050 8060 8070 8080 8090 8100 8110 1+50 80 0 4 . 3 79 9 8 . 9 7 80 0 0 . 7 3 2+00 80 0 7 . 7 80 0 3 . 4 2 80 0 9 . 6 80 0 5 . 6 8 2+50 80 1 2 . 9 80 0 7 . 7 9 80 1 4 . 6 80 1 0 . 8 2 3+00 80 1 8 . 1 80 1 5 . 2 7 80 2 2 . 2 80 2 0 . 2 6 3+50 80 2 6 . 1 80 2 5 . 2 5 80 3 0 . 0 80 3 0 . 2 4 4+00 80 3 3 . 2 80 3 5 . 2 7 80 3 6 . 8 80 4 0 . 2 7 4+50 80 4 3 . 4 80 4 4 . 3 4 80 5 1 . 3 80 4 9 . 2 1 5+00 80 5 9 . 5 80 5 4 . 1 3 80 6 5 . 4 80 5 8 . 8 8 5+50 80 7 1 . 2 80 6 2 . 1 1 80 7 6 . 6 80 6 7 . 9 6 6+00 80 8 0 . 0 80 7 7 . 5 1 80 8 5 . 0 6+50 80 8 9 . 9 80 9 4 . 9 6+85 80 9 7 . 0 2+60.10 STORM XING INV=8001.31' INV IN: 8004.37' 84.2' of 8" SDR-26 @ 7.21% PROPOSED 4'Ø MH-10 STA:2+21.50 RIM:8005.43 8" SDR-26 INV IN:7997.97 8" SDR-26 INV OUT:7997.77 PROPOSED 4'Ø MH-11 STA:4+31.48 RIM:8041.40 8" SDR-26 INV IN:8034.21 8" SDR-26 INV OUT:8034.01 PROPOSED 4'Ø MH-12 STA:6+75.55 RIM:8094.86 EX. 8" INV. IN(S):8091.43 8" SDR-26 INV OUT:8082.22 3.06 209.2' of 8" S D R - 2 6 @ 1 7 . 5 0 % 245.0' of 8" S D R - 2 6 @ 2 0 . 0 0 % 4+50.56 PROPOSED ELEC-TELE T.O.P.=8040.44' SCALE: HORZ. 1" = 20' VERT. 1" = 20' 2+04.03 PROPOSED ELEC-TELE T.O.P.=7999.79' 1+49.33 PROPOSED GAS T.O.P.=7995.92' 4+21.54 PROPOSED GAS T.O.P.=8036.61' 4+39.71 PROPOSED GAS T.O.P.=8039.65' PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE6''WL 16'' WL PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UE FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING LIGHT POLE EXISTING SIGN EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING ELEC, TELE, CABLE, GASXETGC EXISTING GAS XETC XETC EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE EXISTING ELEC, TELE, CABLE XUT XUT XEL XEL XTV XTV XSA XSA NORTH XSD XSD 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 20 8010 LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 1 3 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 3 . 0 0 - C . 3 . 0 2 M A S T E R U T I L I T Y 1 5 1 0 1 . 0 6 . d w g CJB JKS C.3.01 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R RUTHIE'S SANITARY SEWER SERVICE PLAN & PROFILE MA T C H L I N E S T A : 1 + 5 0 S E E B E L O W MA T C H L I N E S T A : 1 + 5 0 S E E A B O V E 15101.06 10-10-20191 SD PRICING RUTHIE'S SEWER PROFILE STA:0+00-1+50 RUTHIE'S SEWER PROFILE STA:1+50-ENDNOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW GOR S U C H S E W E R S E R V I C E RE. T O S H E E T C . 3 . 0 2 3-2-20203 DETAILED REVIEW WL SV C WL SV C WL SV C WL SV C WL SV C T C T C T C T C T C T C T C T C T C GAS GAS G A S G A S SAN SAN G A S G A S GA S GA S GA S GAS GAS GA S GA S U E L U E L U E L U E L U E L U E L UE L UE L UE L UE L UEL UE L UE L DS DS DS DS DS DS SAN > 0+0 0 0+50 1+00 1+10 0+0 0 37.5 ' o f 8 " S D R - 2 6 @ 2 . 0 0 % 63.0' of 8" SDR-26 @ 2.00% 42.5' of 8" SDR-26 @ 2.00% X S A X S A X S A X S A X S A X S A X S A X S A X S A X S A XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XELXUTXUT XUT XUT XU T X U T XU T XUT XUT XUT XU T XUT XUT X U T XU T XU T XE L XE L XE L XE L XE L X E L XE L X E L XE L X E L X E L X E L X E L XE L XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L XE L XE L X E L X E L X E L X E L X E L XE L X E L XE L XE L X E L X E L X E L X E L X E L X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T X U T XU T XEL X E L XEL XEL XEL XSAXSAXSA XS A XS A XSAXSAXSA XSA XSA XSA XS A X S D X S D X S D X S D X S D X S D X S D STA:0+99.25 PROPOSED UTILITY XING STA:0+18.62 PROPOSED UTILITY XING STA:0+54.72 PROPOSED UTILITY XING PROPOSED 4'Ø MH-6 STA:0+00.00 (SEWER SERVICE) RIM:7999.96 EX. 8" INV. IN(SE):7993.91 EX. 8" INV. IN(SE):7988.01 EX. 8" INV. IN(W):7994.48 EX. 8" INV. IN(W):7987.98 PROPOSED 8" SDR-26 INV IN:7987.86 EX. 8" INV. OUT(N):7987.66 PROPOSED 4'Ø MH-7 STA: 0+00 (RUTHIES SEWER SERVICE) STA:0+41.50 (SEWER SERVICE) RIM:8002.27 8" SDR-26 INV IN:7988.81 8" SDR-26 INV IN:7988.81 8" SDR-26 INV OUT:7988.61 2-WAY CLEANOUT W/ FRAME & GRATE STA:1+06.50 RIM:7990.80 8" SDR-26 INV IN:7990.07 8" SDR-26 INV OUT:7990.07 SEWER SERVICE PROFILE 7980 7990 8000 8010 7980 7990 8000 8010 0+00 80 0 0 . 8 80 0 0 . 0 1 80 0 2 . 3 80 0 1 . 1 2 0+50 80 0 3 . 7 80 0 2 . 3 2 80 0 4 . 0 79 9 9 . 0 2 1+00 80 0 3 . 6 79 9 8 . 0 3 1+10 80 0 3 . 5 79 9 8 . 4 3 0+00 STA: 1+06.50 INSTALL 2-WAY CLEANOUT W/ FRAME & GRATE 8" INV @ BLDG: 7990.13' 0+54.72 6" WATER XING B.O.P.= 7991.68' 1.98 0+99.25 10" INV PVC INV: 7993.66' 8" SEWER INV: 7989.03' PROPOSED 4'Ø MH-6 STA:0+00.00 RIM:7999.96 EX. 8" INV. IN(SE):7993.91 EX. 8" INV. IN(SE):7988.01 EX. 8" INV. IN(W):7994.48 EX. 8" INV. IN(W):7987.98 PROPOSED 8" SDR-35 INV IN:7987.86 EX. 8" INV. OUT(N):7987.66 37.5' of 8" SDR-26 @ 2.00% PROPOSED 4'Ø MH-7 STA:0+41.50 RIM:8002.27 8" SDR-26 INV IN:7988.81 8" SDR-26 INV IN:7988.81 8" SDR-26 INV OUT:7988.61 63.0' of 8" SDR-26 @ 2.00%8" SEWER INV: 7989.94' 3.05 SCALE: HORZ. 1" = 10' VERT. 1" = 10' PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE6''WL 16'' WL PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UE FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING LIGHT POLE EXISTING SIGN EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING ELEC, TELE, CABLE, GASXETGC EXISTING GAS XETC XETC EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE EXISTING ELEC, TELE, CABLE XUT XUT XEL XEL XTV XTV XSA XSA N O R T H XSD XSD 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 010 10 20 10 405 LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 1 3 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 3 . 0 0 - C . 3 . 0 2 M A S T E R U T I L I T Y 1 5 1 0 1 . 0 6 . d w g CJB JKS C.3.02 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R GORSUCH HAUS SANITARY SEWER SERVICE PLAN & PROFILE 15101.06 10-10-20191 SD PRICING GORSUCH SEWER SERVICE PROFILE NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW RUTHIES SEWER SERVICE RE. TO SHEET C.3.01 3-2-20203 DETAILED REVIEW 16'' WATER LINE PROFILE 7980 7985 7990 7995 8000 8005 8010 8015 0+00 79 9 2 . 5 79 8 6 . 2 5 79 9 5 . 2 79 8 7 . 6 5 0+50 79 9 7 . 4 79 8 8 . 7 4 79 9 7 . 6 79 8 9 . 0 2 1+00 79 9 6 . 8 79 8 9 . 1 5 79 9 6 . 6 79 8 9 . 2 9 1+50 79 9 6 . 5 79 8 9 . 5 9 79 9 7 . 2 79 9 0 . 1 1 2+00 79 9 8 . 6 79 9 0 . 6 8 80 0 0 . 5 79 9 1 . 2 8 2+50 80 0 2 . 5 79 9 1 . 8 8 STA:0+07.00 LOCATE EXISTING 45° BEND & EXTEND NEW 16" WATER MAIN EX. T.O.P.=7986.55 5.74% 4.81% 3.99% 1.74%2.20% 2.39% 0.54% STA:0+77.39 SERVICE LINE TO GORSUCH PROJECT T.O.P.=7989.03 INSTALL 16"x6" DIP TEE, W/ TBs & MLs. VERIFY SERVICE LINE SIZE PRIOR TO BUILDING PERMIT PROPOSED 24" RCP STORM DRAIN STA:0+32.44 INV.=±7982.51 STA:2+22.94 CONTRACTOR TO LOCATE AND PROTECT EXISTING TELE STA:0+48.35 EX. ELEC/GAS/CABLE TO BE ABANDONED PER GORSUCH HAUS PROJECT STA:0+25.46 INV=7983.0± EX. 8" SANITARY SEWER STA:0+13.13 CONTRACTOR TO LOCATE & PROTECT EX. GAS STA:0+22.09 CONTRACTOR TO LOCATE & PROTECT EX. ETC STA:1+39.43 EX. ELEC. CONTRACTOR TO ABANDON EXISTING LINE AND RE ROUTE PER UTILITY PLAN NOTE: ALLOWABLE PIPE DEFLECTION = 2.5° PER JOINT MAX. STA:1+85.67 T.O.P.=7990.34 INSTALL 45° HORZ. BEND W/ TBs & MLs PROPOSED TOP OF PIPEPROPOSED FINAL GRADE EXISTING GRADE PROPOSED FINAL GRADE STA:0+54.23 T.O.P.=7988.91 2.5° VERT. DEFLECTION STA:0+18.22 CONTRACTOR TO LOCATE & PROTECT EX. CABLE STA:0+21.00 T.O.P.=7987.46 INSTALL 45° HORZ. BEND W/ TBs & MLs STA:1+13.14 T.O.P.=7989.22 16"x6" DIP TEE TO FIRE HYDRANT16" D.I.P. WATER MAIN 16" D.I.P. WATER MAIN STA:1+65.39 T.O.P.=7988.3± EX. 12" WATER MAIN (APPROX. DEPTH) STA:1+89.53 T.O.P.=7988.7± EX. 12" WATER MAIN (APPROX. DEPTH) STA:2+45.96 T.O.P.=7996.7± EX. 12" WATER MAIN (APPROX. DEPTH) HORIZ. SCALE: 1" = 10' VERT. SCALE: 1" = 5' TOP CURB=7998.00 FG=7996.69 STA:1+13.12 PROPOSED FIRE HYDRANT SET TRAFFIC FLANGE @ 7998 APPROX. DEPTH OF CURB WALL @ WATER MAIN CROSSING 2.53' 2.26' STA:0+82.39 T.O.P.=7989.06 16" BFV w/ MLs & TBs STA:0+16.43 T.O.P.=7987.20 16" BFV w/ MLs & TBs X S A X S A XE L XEL XEL XEL X U T X U T X U T X U T x x X S D X S D X S D X S D X S D X S D X S D XE L XE L X E L XEL XEL X E L XE L X E L XE L XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XUT XUT XUT XU T XU T XUT X U T XU T X U T XUT XUT XUT XUT XUT XUT XUT X U T X U T X E L X E L X E L X E L X E L XE L XEL XEL XEL XEL XEL XEL XEL XEL X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L XE L XE L XE L XE L X E L X E L X E L X E L X E L X E L X E L X E L XE L XE L XE L XE L XE L XE L XE L X U T X U T X U T X U T X U T X U T X U T X U T X U T XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS X G A S X G A S XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL X W L X W L X W L X W L X W L X W L X W L XW L X U T XU T XGA S XGA S XSAXSA XS D XS D XS D XS D XS D XS D XS D XS D XS D XS D XS A XS A XS A XS A XS A XS A XS A XS A XS A XW L XW L XW L XWL XWLXWL XG A S XG A S XGA S XGA S XGA S XGA S XGA S X G A S X G A S X G A S X G A S X G A S X G A S X G A S X G A S X G A S XE T C XE T C XE T C XE T C XE T C XE T C XE T C X S D X S D X S D X S D X S D X S D XSDXSDXSDXSD XTV XTV XG A S XG A S XG A S XG A S XG A S XGAS XGAS XELTC T C T C T C T C T C UEL UEL UEL UEL UEL ET ET ET ET ET ET ET ET ET ET ET ET ET E T E T E T E T E T E T E T GAS GAS G A S G A S G A S G A S G A S G A S GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS G A S G A S G A S GA S G A S GA S SAN > > > > > > > > >>SAN G A S U E L U E L U E L U E L U E L U E L U E L SAN 8'' SA 8'' SA 8'' SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8'' SA 8'' SA 8'' SA 8'' SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8 ' ' S A 8 ' ' S A 8' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' SAN TEL TEL TEL TEL TEL TEL TEL TEL 16'' WATER LINE ALIGNMENT STA: 0+00.00 STA: 1+85.67 INSTALL 16" 45° HORZ. BEND W/ TBs & MLs PROPOSED WATER SERVICE TO GORSUCH HAUS PROJECT STA:0+77.39 16"x6" DIP TEE, (2) 16" BFV, & (1) 6" GV W/ TBs & MLs. SERVICE SIZE TO BE VERIFIED PRIOR TO BUILDING PERMIT. STA:0+32.44 STORM DRAIN CROSSING STA:2+22.94 CONTRACTOR TO LOCATE & PROTECT EXISTING TELE SERVICE STA:2+64.49 TELE CROSSING EX. GAS SERVICE TO BE RE ROUTED AROUND DEVELOPMENT STA:0+48.35 EX. ELEC. SERVICE LINES TO BE ABANDONED PER GORSUCH HAUS PROJECT STA:0+25.46 SANITARY SEWER CROSSING STA:0+13.13 GAS CROSSING STA:0+22.09 ETC CROSSING S. A S P E N S T . 0+ 0 0 0+25 0+50 0+75 1+00 1+25 1+50 1+75 2 + 0 0 2 + 2 5 2 + 5 0 EX. 12" WATER MAIN TO BE ABANDONED PER CITY OF ASPEN WATER DEPARTMENT STANDARDS EX. STORM DRAIN TO BE ABANDONED PER GORSUCH HAUS IMPROVEMENTS 15.0 ' 15.0 ' 6.5' UTILITY EASEMENT 30.0 ' W A T E R L I N E EA S E M E N T 30.0 0 ' W A T E R L I N E EA S E M E N T STA:0+21.00 INSTALL 16" 45° HORIZ BEND w/ TB AND MLs STA:1+13.14 OFF:4.62'L NEW FIRE HYDRANT ASSEMBLY 16"X6" DIP TEE, (1) 6" GV W/ TBs & MLs SET TRAFFIC FLANGE @ 7998 0+ 0 0 0+ 5 0 SANITARY SEWER XING STA:0+41.52 STA:0+15.30 PROPOSED GAS XING STA:0+12.30 PROPOSED PRIMARY ELEC. XING 16" DIP STA:0+07.00 CES #1: LOCATE EXISTING 45° BEND, DISCONNECT EX. 16" MAIN & EXTEND NEW MAIN AS SHOWN ASBUILT DATA: TOP OF PIPE = 7986.55 N:1484915.244 E:2624918.507 STA:0+82.39 16" BFV w/ MLs & TBs STA:0+05.00 WATER SERVICE ALIGNMENT 6" GV w/ MLs STA:0+19.50 INSTALL 6" 11.25° VERT. BEND w/ TB AND MLs STA:0+33.00 INSTALL 6" 11.25° VERT. BEND w/ TB AND MLs STA:0+09.12 STORM DRAIN CROSSING SANITARY SEWER XING STA:0+53.91 25' HILL STREET RIGHT OF WAY STA:1+65.39 EX. 12" WATER STA:1+89.53 EX. 12" WATER STA:2+45.96 EX. 12" WATER XING EX. STORM DRY WELL TO BE ABANDONED TOP OF CMP = 7996'± DEBRIS FLOW WALL STA:0+16.43 16" BFV w/ MLs 7980 7985 7990 7995 8000 8005 8010 8015 1.ALL MINIMUM DEPTHS, SEPARATION DISTANCES, MATERIALS AND/OR USE OF CONDUIT SHALL BE CONFIRMED AND COORDINATED WITH THE UTILITY PROVIDER PER UTILITY AGREEMENTS. 2.ALL UTILITY LINES AND/OR CONDUITS TO BE BACKFILLED WITH SUITABLE MATERIAL FREE OF ROCKS >1 1/2" Ø. USE CLASS 6 AGGREGATE BASE MATERIAL FOR BEDDING, AND/OR SUITABLE ONSITE MATERIAL. INSTALL PER UTILITY PROVIDER SPECIFICATIONS. BACKFILL TRENCHES WITH SUITABLE ONSITE MATERIALS. MINIMUM COMPACTION 95% IN PAVED AREAS. 3.GAS AND ELECTRIC TO BE INSTALLED IN SEPARATE TRENCHES. SEWER SERVICES TO BE INSTALLED A MINIMUM 10' FROM WATER SERVICES AS FEASIBLE. COMMUNICATIONS MAY BE INSTALLED IN COMBINED TRENCHES PER CONSTRUCTION FEASIBILITY AS LONG AS MINIMUM SEPARATION DISTANCES AND DEPTHS OF BURY ARE MAINTAINED. INSTALL WARNING TAPE OVER ALL UTILITY LINES. UTILITY SERVICE MINIMUM DEPTH WATER--------------------------------7.0' SEWER--------------------------------5.0' ELECTRIC----------------------------4.0' CABLE TV----------------------------3.0' PHONE--------------------------------3.0' GAS----------------------------------- 3.0' 1.CONTRACTOR TO COORDINATE ABANDONMENT, RELOCATION, AND BURIAL OF THE EXISTING UTILITIES WITH THE UTILITY PROVIDERS. CONTRACTOR TO PROVIDE ALL TRENCHING, BEDDING, AND BACKFILL WORK NECESSARY FOR UTILITY RELOCATION. 2.THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION OPERATIONS WITHIN THE LIMITS OF CONSTRUCTION. CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR CONSENT OF THE PROPERTY OWNER(S) INVOLVED. 3.THE LOCATIONS OF UNDERGROUND UTILITIES HAVE BEEN PLOTTED BASED ON UTILITY MAPS, LOCATES OR OTHER INFORMATION PROVIDED BY UTILITY COMPANIES AND ACTUAL FIELD LOCATIONS IN SOME INSTANCES. THESE UTILITIES, AS SHOWN MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATION OF UTILITIES PRIOR TO CONSTRUCTION. 4.CONTRACTOR TO COORDINATE ALL UTILITY LINEWORK WITH THE RESPECTIVE UTILITY COMPANY PRIOR TO CONSTRUCTION. 5.EXISTING WATER MAIN TO BE COMPLETELY REMOVED PER COA WATER DEPT. STANDARDS GENERAL UTILITY NOTES:SHALLOW UTILITY NOTES: 16" WATER LINE PROFILE STA: 0+00 - 2+50 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 2 : 1 0 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 3 . 0 3 - C . 3 . 0 6 W A T E R M A I N P P 1 5 1 0 1 . 0 6 . D W G JKS C.3.03 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R 16" WATER MAIN PLAN & PROFILE STA: 0+00-2+50 PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UEL UEL FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING LIGHT POLE EXISTING SIGN EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')20'STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING GAS EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE XUT XUT XEL XEL XTV XTV XSA XSA XSD XSD LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 10 16" WATER LINE PLAN VIEW STA: 0+00 - 2+50 MAT C H L I N E S T A : 2 + 5 0 SEE S H E E T C . 3 . 0 4 MA T C H L I N E S T A : 2 + 5 0 SE E S H E E T C . 3 . 0 4 CJB NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW PROJECT NUMBER:15101.06 6" WATER SERVICE TO LODGE; RE. TO SHEET C. 3.05 FOR PLAN & PROFILE PROPOSED SITE WALL W/ FOOTER; RE. TO PED. RAMP WALL DETAIL THIS SHEET STANDARD CURB (IE. NO FOOTER REQUIRED BEYOND THIS POINT) PED. RAMP PROPOSED 16" WATER MAIN @ 7-FT MIN. BURY DEPTH PER COA WATER DEPT. STANDARDS PROPOSED BEDDING ZONE PER COA WATER DEPARTMENT STANDARDS 3' 6" PROPOSED CANTILEVER FOOTING (WITHOUT HEEL). SET BOTTOM OF FOOTING BELOW FROST DEPTH OR PLACED 12" BELOW ADJACENT WATER MAIN (AS REQ'D). FINAL DESIGN OF WALL TO BE PROVIDED IN SUPPORT OF BUILDING PERMIT APPLICATION VARIES 2.5' MAX. RI G H T - O F - W A Y PROPOSED PED. RAMP WALL DETAIL N.T.S. 12" 3-2-20203 DETAILED REVIEW TRENCH DRAIN 12" (MIN.) 16'' WATER LINE PROFILE 7980 7985 7990 7995 8000 8005 8010 2+50 80 0 2 . 5 79 9 1 . 8 8 80 0 4 . 6 79 9 2 . 4 7 3+00 80 0 6 . 4 79 9 2 . 8 6 79 9 3 . 1 5 3+50 79 9 3 . 4 4 79 9 3 . 7 3 4+00 79 9 3 . 7 7 79 9 3 . 5 6 4+50 5+00 5+10 STA:2+82.79 T.O.P.=7992.66 INSTALL 45° HORZ. BEND W/ TBs & MLs 1.16%-0.81% STA:3+87.21 HIGH POINT T.O.P.=7993.87 16"x6" DIP TEE RECONNECT TO EXISTING HYDRANT STA:4+16.74 T.O.P.=7993.63 16"x8" DIP TEE STA:4+93.26 T.O.P.=7993.05 12"x6" D.I.P. TEE, 6"x4" REDUCER 4" GV. & 7LF 4" D.I.P. FIELD VERIFY EX. WS SIZE STA:4+19.07 EX. CABLE STA:4+27.43 CONTRACTOR TO LOCATE & PROTECT EX. GAS (TYPICAL AT ALL EX. UTILITY CROSSINGS) STA:4+04.72 EX. ELEC STA:3+99.87 EX. ELEC STA:2+91.47 STORM DRAIN TO BE ABANDONED PER GORSUCH HAUS IMPROVEMENTS STA:2+64.49 EX. TELE SERVICE. CONTRACTOR TO LOCATE & PROTECT (TYP. @ ALL UTIL. CROSSING LOCATIONS) NOTE: ALLOWABLE PIPE DEFLECTION = 2.4° PER JOINT MAX. STA:4+05.75 T.O.P.=7993.72 16"x6" DIP TEE EXISTING GRADE PROPOSED FINAL GRADE STA:3+13.47 T.O.P.=7993.02 16" BFV w/ MLs & TBs STA:3+03.47 T.O.P.=7992.90 16" BFV w/ MLs & TBs STA:3+92.21 T.O.P.=7993.83 16" BFV w/ MLs & TBs16" D.I.P. WATER MAIN 16" D.I.P. WATER MAIN STA:3+08.47 SERVICE LINE TO MOUNTAIN QUEEN T.O.P.=7992.96 INSTALL 16"x6" DIP TEE, W/ TBs & MLs. VERIFY SERVICE LINE SIZE PRIOR TO BUILDING PERMIT STA:3+94.23 EX. TELE-CABLE STA:4+36.22 T.O.P.=7993.47 CES#2 W/ 16" BFV & 16"X12" REDUCER & CONTINUE WITH NEW 16" WATER MAIN FIELD VERIFY EX. ELEVATION EX. VALVE TO REMAIN STA:2+80.09 T.O.P.=8000.5± EX. 12" WATER MAIN (APPROX. DEPTH) STA:4+15.74 T.O.P.=7993.9± EX. 8" WATER MAIN (APPROX. DEPTH) HORIZ. SCALE: 1" = 10' VERT. SCALE: 1" = 5' STA:3+87.21 EX. HYDRANT 14' MAX. BURY DEPTH TO ESTABLISH HIGH POINT @ FIRE HYDRANT X S D X S D X S D X S D X S D X S D X W L X W L X W L XUT XU T XU T XUT XUT XUT X U T XU T X U T XW L XG A S XG A S X G A S X G A S X G A S X G A S XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS X W L XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XW L X W L XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XT V XT V XT V XU T XU T XTV XTV XT V XT V XTV XTV XTV XTV XUT XUT XUT XUT XUT XUT XUT XUT XTV XTV XT V XT V XTV XTV XTV XTV X U T XUT XUT X U T X U T XUT XUT XUT XUTXTVXTVXTV XTV XELXEL X E L X E L X E L X E L X E L X E L X E L XEL XE L XE L X E L X E L X E L XE L XE L XE L XE L XE L XE L X E L X E L XTV XTV XTV XUT X W L X W L X W L X W L X W L X W L X W L X W L XW L XW L XW L XW L XW L XW L XW L XW L 12" DIP 12" DIP 6" CIP 4" 6" CIP 6 " C I P 8" C I P 6" C I P 8" CIP 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' E T E T E T E T E T E T E T E T E T E T E T E T E T G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S G A S > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > SAN 8 ' ' S A 8' ' S A 8 ' ' S A 8 ' ' S A 4'' WL 4'' WL UEL UEL UEL UEL 6' ' W L 6' ' W L 6 ' ' W L 6 ' ' W L 6 ' ' W L 6 ' ' W L 6' ' WL 6' ' WL 6''WL 6''WL 6''WL 6''WL 6''WL 6''WL 6''WL 6''WL 6''WL 6''WL END 16'' WATER LINE ALIGNMENT STA: 5+00.00 STA: 2+82.79 INSTALL 16" 45° HORZ. BEND W/ TBs & MLs PI : 4 + 1 3 . 9 5 STA: 4+39.52 EXISTING 12"STA:4+27.43 GAS CROSSING STA:4+17.11 OFF:19.45'L CONNECT TO EX. 8" LINE @ TEE STA:4+05.75 16"x6" DIP TEE W/ TBs & MLs STA:4+93.25 OFF:6.79'R CONNECT NEW 4" WS TO EX. 4" WS LINE & REMOVE OR BURY EX. VALVE FIELD VERIFY EX. WS SIZE STA:4+93.26 4" HOT TAP W/ VALVE STA:3+87.21 16"x6" DIP TEE, (1) 16" BFV W/ TBs & MLs STA:3+88.09 OFF:11.39'L EXISTING FIRE HYDRANT ASSEMBLY TO REMAIN STA:4+19.07 CABLE CROSSING STA:4+04.72 ELECTRIC CROSSING STA:3+99.87 ELECTRIC CROSSING EXISTING STORM DRAIN TO BE ABANDONED PER GORSUCH HAUS IMPROVEMENTS TOP OF CMP = 8004.7'± STA:2+64.49 TELE CROSSING MO N A R C H S T . SUMMIT ST. 2 + 5 0 2 + 7 5 3+00 3+25 3+50 3+75 4+00 4+25 4+50 4+75 5+00 STA:4+16.74 16"x8" DIP TEE W/ TBs & MLs 15.0 ' 30.0 0 ' W A T E R L I N E EA S E M E N T MOUNTAIN QUEEN STA:3+90.53 OFF:5.91'L INSTALL DRY HYDRANT RISER w/ (3) FIRE DEPARTMENT CONNECTIONS TO SERVE DRY HYDRANTS ALONG WEST SIDE OF MOUNTAIN QUEENT STA:3+03.47 16" BFV w/ MLs & TBs STA:3+13.47 16" BFV w/ MLs & TBs PROPOSED WATER SERVICE TO MOUNTAIN QUEEN PROJECT STA:3+08.47 16"x6" DIP TEE, (2) 16" BFV, & (1) 6" GV W/ TBs & MLs. SERVICE SIZE TO BE VERIFIED PRIOR TO BUILDING PERMIT. STA:3+08.47 OFFSET:3.00'R 6" GV w/ MLs STA:3+08.57 OFFSET:5.23'R TIE INTO EXISTING SERVICE LINE STA:3+92.21 16" BFV w/ MLs & TBs STA:3+87.52 OFFSET:-7.44'L CONNECT TO EX. HYDRANT VALVE STA:3+94.23 TELE-CABLE CROSSING PROPOSED 6" G.V. W/ MLs & TBs THEN RE-CONNECT TO EXISTING 6" CIP STA:4+17.17 OFFSET:-16.00'L 8" GV w/ MLs STA:2+45.96 EX. 12" WATER XING STA:2+80.09 EX. 12" WATER STA:4+15.74 EX. 8" WATER EX. 25-FT SKIER & PED ESMNT (BK 4 PG 489) & WATER MAIN EASEMENT (BK 411 PG 996) EXISTING WATER SERVICE TO MOUNTAIN QUEEN EX. 20-FT FIRE ACCESS & DRAINAGE ESMNT (BK 275 PG 378) & WATERLINE ESMNT (BK 291 PG 649) PROPOSED 6" DUCTILE IRON DRY HYDRANT LINE @ 3.5' MIN. BURY DEPTH CONTRACTOR TO LOCATE EXISTING 6" WATER LINE AND CONFIRM INTEGRITY. IF ACCEPTABLE AND VERT. GRADES ARE ACHIEVABLE CONNECT TO EXISTING 6" LINE, OTHERWISE REPLACE EXISTING 6" IN IT'S ENTIRETY. PLUG EX. 6" WATER LINE AT SOUTH END OF EX. SERVICE TEE PROPOSED 6" DUCTILE IRON DRY HYDRANT LINE @ 3.5' MIN. BURY DEPTH STA:4+36.22 CES#2: LOCATE EXISTING 12" MAIN & INSTALL 16" BFV & 16"X12" REDUCER W/ TBs & MLs & CONNECT TO EX. 12" W/ SOLID SLEEVE 7980 7985 7990 7995 8000 8005 8010 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 10 16" WATER LINE PROFILE STA: 2+50 - END DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 2 : 1 7 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 3 . 0 3 - C . 3 . 0 6 W A T E R M A I N P P 1 5 1 0 1 . 0 6 . D W G JKS C.3.04 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UEL UEL FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')20'STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING GAS EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE XUT XUT XEL XEL XTV XTV XSA XSA XSD XSD LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES 16" WATER MAIN PLAN & PROFILE STA: 2+50-END 16" WATER LINE PLAN VIEW STA: 2+50 - END MAT C H L I N E S T A : 2 + 5 0 SEE S H E E T C . 3 . 0 3 MA T C H L I N E S T A : 2 + 5 0 SE E S H E E T C . 3 . 0 3 CJB NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW PROJECT NUMBER:15101.06 1.ALL MINIMUM DEPTHS, SEPARATION DISTANCES, MATERIALS AND/OR USE OF CONDUIT SHALL BE CONFIRMED AND COORDINATED WITH THE UTILITY PROVIDER PER UTILITY AGREEMENTS. 2.ALL UTILITY LINES AND/OR CONDUITS TO BE BACKFILLED WITH SUITABLE MATERIAL FREE OF ROCKS >1 1/2" Ø. USE CLASS 6 AGGREGATE BASE MATERIAL FOR BEDDING, AND/OR SUITABLE ONSITE MATERIAL. INSTALL PER UTILITY PROVIDER SPECIFICATIONS. BACKFILL TRENCHES WITH SUITABLE ONSITE MATERIALS. MINIMUM COMPACTION 95% IN PAVED AREAS. 3.GAS AND ELECTRIC TO BE INSTALLED IN SEPARATE TRENCHES. SEWER SERVICES TO BE INSTALLED A MINIMUM 10' FROM WATER SERVICES AS FEASIBLE. COMMUNICATIONS MAY BE INSTALLED IN COMBINED TRENCHES PER CONSTRUCTION FEASIBILITY AS LONG AS MINIMUM SEPARATION DISTANCES AND DEPTHS OF BURY ARE MAINTAINED. INSTALL WARNING TAPE OVER ALL UTILITY LINES. UTILITY SERVICE MINIMUM DEPTH WATER--------------------------------7.0' SEWER--------------------------------5.0' ELECTRIC----------------------------4.0' CABLE TV----------------------------3.0' PHONE--------------------------------3.0' GAS----------------------------------- 3.0' SHALLOW UTILITY NOTES: 3-2-20203 DETAILED REVIEW 1.CONTRACTOR TO COORDINATE ABANDONMENT, RELOCATION, AND BURIAL OF THE EXISTING UTILITIES WITH THE UTILITY PROVIDERS. CONTRACTOR TO PROVIDE ALL TRENCHING, BEDDING, AND BACKFILL WORK NECESSARY FOR UTILITY RELOCATION. 2.THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION OPERATIONS WITHIN THE LIMITS OF CONSTRUCTION. CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR CONSENT OF THE PROPERTY OWNER(S) INVOLVED. 3.THE LOCATIONS OF UNDERGROUND UTILITIES HAVE BEEN PLOTTED BASED ON UTILITY MAPS, LOCATES OR OTHER INFORMATION PROVIDED BY UTILITY COMPANIES AND ACTUAL FIELD LOCATIONS IN SOME INSTANCES. THESE UTILITIES, AS SHOWN MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATION OF UTILITIES PRIOR TO CONSTRUCTION. 4.CONTRACTOR TO COORDINATE ALL UTILITY LINEWORK WITH THE RESPECTIVE UTILITY COMPANY PRIOR TO CONSTRUCTION. 5.EXISTING WATER MAIN TO BE COMPLETELY REMOVED PER COA WATER DEPT. STANDARDS GENERAL UTILITY NOTES: WATER SERVICE PROFILE 7980 7985 7990 7995 8000 8005 8010 8015 7980 7985 7990 7995 8000 8005 8010 8015 0+00 79 9 7 . 6 79 8 9 . 0 1 79 9 7 . 9 79 9 0 . 2 9 0+50 80 0 2 . 0 79 9 2 . 0 0 79 9 9 . 8 79 9 2 . 1 1 1+00 79 9 9 . 0 79 9 2 . 2 3 1+07 79 9 9 . 4 79 9 2 . 2 6 STA: 0+12.30 PROPOSED ELEC. ELEV= 7993.49' STA: 0+15.30 PROPOSED GAS ELEV= 7994.60' PROPOSED 18" RCP STORM DRAIN STA: 0+09.12 INV= 7985.07' SANITARY SEWER CROSSING STA: 0+41.52 8" INV= 7989.14' STA: 0+53.91 T.O.P.= 7992.02' 1.5° VERT. DEFLECTION STA:0+00.00 SERVICE LINE TO GORSUCH PROJECT T.O.P.=7989.03 INSTALL 16"x6" DIP TEE, W/ TBs & MLs. VERIFY SERVICE LINE SIZE PRIOR TO BUILDING PERMIT SANITARY SEWER CROSSING STA: 0+53.91 8" INV= 7989.04' STA: 0+41.52 T.O.P.= 7991.96' STA: 0+05.00 T.O.P.= 7988.72' 6" GV w/ MLs DIST=-1.53'STA:0+19.50 T.O.P.=7989.28 INSTALL 11.25° VERT. BEND W/ TBs & MLs STA:0+33.00 T.O.P.=7991.76 INSTALL 11.25° VERT. BEND W/ TBs & MLs DIST=-1.55'DIST=-1.72' STA: 1+07.07 T.O.P.= 7992.26' (RE. MECH FOR CONTINUATION) HORIZ. SCALE: 1" = 10' VERT. SCALE: 1" = 5' PROPOSED TOP OF PIPEPROPOSED FINAL GRADE 3.86% 18.89% 2.22%0.45% GR A D E B R E A K S T A = 0 + 0 0 . 0 0 EL E V = 7 9 8 9 . 0 1 GR A D E B R E A K S T A = 1 + 0 7 . 0 7 EL E V = 7 9 9 2 . 2 6 XELXEL X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L XEL XEL XEL XEL XEL XEL XEL XEL XEL XELXEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XELXEL XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XW L XW L XW L XW L XW L XW L XW L XS D XS D U E L ET ET ET ET ET GA S GA S GA S GA S GA S GA S GA S S A N 8' ' SA 8' ' SA 8' ' SA 8' ' SA 8' ' DS 8' ' S A 8' ' S A 8' ' S A 8' ' S A 8' ' SA S A N PROPOSED WATER SERVICE TO GORSUCH HAUS PROJECT STA:0+77.39 16"x6" DIP TEE, (1) 16" BFV, & (1) 6" GV W/ TBs & MLs. SERVICE SIZE TO BE VERIFIED PRIOR TO BUILDING PERMIT. EX. GAS SERVICE TO BE RE ROUTED AROUND DEVELOPMENT 0+ 7 5 1+ 0 0 0+00 0+50 1+00 1+07 SANITARY SEWER XING STA:0+41.52STA:0+15.30 PROPOSED GAS XING STA:0+12.30 PROPOSED PRIMARY ELEC. XING 16 " D I P STA:0+82.39 16" BFV w/ MLs & TBs STA:0+05.00 WATER SERVICE ALIGNMENT 6" GV w/ MLs STA:0+19.50 INSTALL 6" 11.25° VERT. BEND w/ TB AND MLs STA:0+33.00 INSTALL 6" 11.25° VERT. BEND w/ TB AND MLs STA:0+09.12 STORM DRAIN CROSSING SANITARY SEWER XING STA:0+53.91 STA:1+07.07 (RE. TO MECH. PLANS FOR CONTINUATION) LI F T O N E L O D G E 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 10 6" WATER SERVICE PROFILE DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 2 : 2 3 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 3 . 0 3 - C . 3 . 0 6 W A T E R M A I N P P 1 5 1 0 1 . 0 6 . D W G JKS C.3.05 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R 6" WATER SERVICE PLAN & PROFILE PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UEL UEL FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')20'STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING GAS EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE XUT XUT XEL XEL XTV XTV XSA XSA XSD XSD LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES CJB NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW PROJECT NUMBER:15101.06 1.ALL MINIMUM DEPTHS, SEPARATION DISTANCES, MATERIALS AND/OR USE OF CONDUIT SHALL BE CONFIRMED AND COORDINATED WITH THE UTILITY PROVIDER PER UTILITY AGREEMENTS. 2.ALL UTILITY LINES AND/OR CONDUITS TO BE BACKFILLED WITH SUITABLE MATERIAL FREE OF ROCKS >1 1/2" Ø. USE CLASS 6 AGGREGATE BASE MATERIAL FOR BEDDING, AND/OR SUITABLE ONSITE MATERIAL. INSTALL PER UTILITY PROVIDER SPECIFICATIONS. BACKFILL TRENCHES WITH SUITABLE ONSITE MATERIALS. MINIMUM COMPACTION 95% IN PAVED AREAS. 3.GAS AND ELECTRIC TO BE INSTALLED IN SEPARATE TRENCHES. SEWER SERVICES TO BE INSTALLED A MINIMUM 10' FROM WATER SERVICES AS FEASIBLE. COMMUNICATIONS MAY BE INSTALLED IN COMBINED TRENCHES PER CONSTRUCTION FEASIBILITY AS LONG AS MINIMUM SEPARATION DISTANCES AND DEPTHS OF BURY ARE MAINTAINED. INSTALL WARNING TAPE OVER ALL UTILITY LINES. UTILITY SERVICE MINIMUM DEPTH WATER--------------------------------7.0' SEWER--------------------------------5.0' ELECTRIC----------------------------4.0' CABLE TV----------------------------3.0' PHONE--------------------------------3.0' GAS----------------------------------- 3.0' SHALLOW UTILITY NOTES: 3-2-20203 DETAILED REVIEW 1.CONTRACTOR TO COORDINATE ABANDONMENT, RELOCATION, AND BURIAL OF THE EXISTING UTILITIES WITH THE UTILITY PROVIDERS. CONTRACTOR TO PROVIDE ALL TRENCHING, BEDDING, AND BACKFILL WORK NECESSARY FOR UTILITY RELOCATION. 2.THE CONTRACTOR SHALL CONTAIN HIS CONSTRUCTION OPERATIONS WITHIN THE LIMITS OF CONSTRUCTION. CONTRACTOR SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT THE PRIOR CONSENT OF THE PROPERTY OWNER(S) INVOLVED. 3.THE LOCATIONS OF UNDERGROUND UTILITIES HAVE BEEN PLOTTED BASED ON UTILITY MAPS, LOCATES OR OTHER INFORMATION PROVIDED BY UTILITY COMPANIES AND ACTUAL FIELD LOCATIONS IN SOME INSTANCES. THESE UTILITIES, AS SHOWN MAY NOT REPRESENT ACTUAL FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT ALL UTILITY COMPANIES FOR FIELD LOCATION OF UTILITIES PRIOR TO CONSTRUCTION. 4.CONTRACTOR TO COORDINATE ALL UTILITY LINEWORK WITH THE RESPECTIVE UTILITY COMPANY PRIOR TO CONSTRUCTION. 5.EXISTING WATER MAIN TO BE COMPLETELY REMOVED PER COA WATER DEPT. STANDARDS GENERAL UTILITY NOTES: ET XEL EX I S T I N G Y A R D H Y D R A N T TY P O F R E T A I N I N G WA L L XSD > EX-01 19.06 ACRES EX-02 5.019 ACRES EX-04 126.27 ACRES EX-03 3.019 ACRES > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >>> > > > > > > > > > > >> >> > > > > > > >>> >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > > > > > > > > > > > > > > > > > > > > > > > > > NORTH 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0200 200 400 200 800100 PIONEER GULCH MT. QUEEN OS-5 SHADOW MOUNTAIN LIFT ONE LODGE DOLINSEK EX-04 (MODELED IN TETRA TECH MUD FLOW) INCLUDES PORTIONS OF BASIN 20 & ALL OF BASIN 21 AS DESCRIBED WITHIN THE CITY'S MASTER DRAINAGE STUDY EX-01 INCLUDES A PORTION OF BASIN 9 AS DESCRIBED WITHIN THE CITY'S MASTER DRAINAGE STUDY PORTION OF BASIN 20 NOT CONTRIBUTING TO PIONEER GULCH DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED: PROJECT NUMBER: DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 6 , 2 0 2 0 - 1 2 : 4 8 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 4 . 0 0 - C . 4 . 0 1 - C . 4 . 0 3 - D R N B A S I N S . d w g C.4.00 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R EXISTING OFFSITE DRAINAGE BASIN PLAN JPP JKS 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW EX LIFT BUILDING MH-D/SUJMP INLET SPLIT CLEAR WATER FLOW PROVIDED BY TETRA TECH. 100 YEAR Q = 13.0 CFS 10 YEAR Q = 0.5 CFS EX. STORM INLET DP J#01 ASPEN S T R E E T MONA R C H S T R E E T S. ASPEN ST. TOWNHOMES SITE BOUNDARY EX. STORM INLET DP J#02 15101.06 NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. EX. STORM INLET DP OS-5 3-2-20203 DETAILED REVIEW EX. STORM INLET DP J#03 NOTE: SPLIT FLOW FROM PIONEER GULCH WAS PROVIDED BY TETRA TECH. THIS FLOW WILL BE CONVEYED THROUGH EX-03 AND FOLLOW THE SAME DRAINAGE PATTERNS. > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >>>>>>> X S D X S D XS D XS D XS D XS D XS D X S D XSD X S D S. ASPEN STREET BASIN DE-01 DE-02 6'' WL 2 ' ' > > > TOP BACK WALLTOP FACE WALLWALL STEPBOTTOM WALLCHAIN LINK FENCE/6FTBOTTOM WALL POST OS1 22.60 ACRES POST OS3.3 > > > > > > > >>> > >> > > > > > > >>> > > > > >>>>>>>>>>> >> > > > > > > >> > >> > > > > > > > >> > > > > > > >>>> > > > > > > > > > > > >>> > > > > > > > > > > S. ASPEN STREET BASIN DE-01 DE-02 EX-OS5 074 ACRES SHADOW MT TH POST OS3.4 Post OS3.2 Post OS3.1 POST ONSITE; RE. BLOWUP NO R T H 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0100 100 200 100 40050 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 2 : 3 0 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 4 . 0 0 - C . 4 . 0 1 - C . 4 . 0 3 - D R N B A S I N S . d w g C.4.01 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R POST DEV. DRAINAGE BASIN PLAN 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 040 40 80 40 16020 JPP JKS 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW M T . Q U E E N LIFT ONE LODGE WEST STORM INLET #3 (DP#J-01) AS P E N S T R E E T S. ASPEN ST. TOWNHOMES CES EX INLET OS5 INLET #7 (SUMP) STORM MH 'B' EAST STORM MH 'C' (DP#J-03) EAST STORM MH 'D' SERVES AS SUMP INLET WEST SWALE STORM MH 'B' EAST STORM MH 'C' (DP#J-03) EAST STORM MH-D STORM INLET #1 & #4 (DP#J-02) WEST W.Q. VAULT EAST W.Q. VAULT EAST ONSITE STORM PIPE ROOF EXTENT (TYPICAL). BUILDING EXTENT (TYP). SITE STORM SEWER INLETS & PIPES (TYP). AS P E N S T R E E T WEST SWALE ROADSIDE SWALE WEST STORM INLET #3 (DP#J-01) PROJECT NUMBER:15101.06 NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. CES COA INLET 1 STORM MH 'A' CES COA INLET 4 INLET #6 (ON-GRADE) INLET #8 (ON-GRADE) WEST ONSITE STORM PIPE SPLIT FLOW FROM EX-04 10 YR=0.5 cfs 100YR=13 cfs 3-2-20203 DETAILED REVIEW XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XG A S XGAS XGAS XGAS XEL XEL XEL XEL uc ucucuc XE L XE L XEL X E L XEL X E L XEL XEL X T V XTV uu XT V XU T XUT XUT XUT XUT XUT XUT XUT XUT XUT XSD XSD XSD XSD XSD XEL XE L XELXEL X E L X E L X E L XE L XE L X E L XE L XE L XE L XU T XU T XU T XUT XU T XU T XU T XUT XGAS XGAS XUT XUT XUT XUT XUT XUTXUT XU T X U T XUT XUTXUT XEL XEL XEL XE L XE L XE L X E L X E L X E LXEL XEL XELXELXELXELXEL XEL XEL XELXEL XEL XEL X E L X E L X E L X E L X E L XEL XEL XEL XEL XEL XELXELXELXELXEL XEL XEL XEL XELXEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XE L XE L XE L XE L XE L XE L XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XELXELXEL XEL XELXELXELXELXEL XU T XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XU T XU T XU T XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XG A S XGAS XG A S XE L XE L XE L XE L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L XWL XWL XWL XUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUT X U T X U T X U T XU T X U T X U T XUT XUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUTXUT XUT XUT XUT XUT XEL XEL XGAS X G A S XU T XU T XU T XEL X E L XS A XSA XW L XW L XW L XW L XW L XW L XW L XW L XW L XW L X S D XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSA XSA XSA XSA XSA XSA XSA XSA XSA XWL XWL XWL XWL XWL XWL XWL XW L XGAS X G A S X G A S XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGA S XETC XETC XETC XETC XETC XETC XETC XETC XSD XSD XSD XS D XS D XWL XWL XWL XWL XWL XWL XT V XUTXUT XGASXGASXGASXGASXGASXGASXGAS XE L WL SVC WL SVC WL SVC TC TC TC TC TC 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' WL 16 ' ' 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8'' S A 8'' S A 8'' SA 8'' SA 8'' S A 8'' SA 8'' SA 8'' SA 8'' SA 8'' SA 8'' S A 8'' S A U E L U E L ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET UEL U E L U E L U E L GA S GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GA S G A S G A S G A S GAS GAS GAS GAS GAS G A S G A S G A S GA S G A S GA S GA S GA S GA S GA S GA S GA S GA S GAS GAS GAS GAS S W I T C H G E A R R E C L O S E R X F R M R S A N > > > >>>>>>>>>>> > > > > > > > > > > > > > > >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > > > > > S A N S A N GAS GAS GA S GAS GAS GAS GAS GAS GAS GAS G A S UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL S A N S A N 8'' SA 8' ' SA 8 ' ' S A 8' ' SA 8'' S A 8'' S A 8 ' ' SA 8' ' SA 8 ' ' SA 8' ' SA 8'' SA 8'' SA 8'' SA 8'' SA 4'' WL UELUE L U E L S A N XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL T E L TE L TE L > > > > > > > > >>>>>>>>>> > > > > >>>>>>>>>>>>>>>>>>>>>>> T E L T E L T E L T E L T E L T E L TEL > > > > > > > > > > > > > > > 6'' WL 6''WL 6''WL 6''WL 6' ' WL 6' ' WL 6' ' WL 6' ' XG A S XG A S XG A S XG A S XG A S S. ASPEN STREET 18 " R C P WEST STORM , RE: C.4.04 10" PVC 10" PVC 10" PVC 80 7 0 80 3 6 8018 8000 8000 8 0 1 0 8 0 2 0 8 0 3 0 8 0 4 0 80 5 0 8 0 4 0 80 6 0 807 2 808 0 80 6 0 8 0 7 0 8 0 8 0 EA S T S T O R M , R E : C . 4 . 0 5 EAST S T O R M , R E : C . 4 . 0 6 8040 802 0 18 " R C P 18" RCP 6" P V C 18" H D P E 15" H D P E 8" HDP E 1 2 " H D P E REMOVE EXISTING COA STORM DRAIN CURB INLET NEW COA STORM DRAIN VALLEY INLET SEE SHEET C.4.05 WEST SAND FILTER VAULT RE: C.4.05 FOR PROFILE EAST SAND FILTER VAULT SEE SHEET C.4.05 FOR PROFILE STORM INLET STRUCTURE (INLET #3) W/ WINGWALLS; INSIDE DIM. OF STRUCTURE TO MATCH EX. INLET STRUCTURE; RE-INSTALL INLET GRATE FROM ABANDONED INLET STRUCTURE LIMITS OF LOWER LEVEL STRUCTURE, TYP WEST SWALE. SEE SHEET 2.06 FOR FURTHER INFORMATION PATIO DRAIN, TYP ABANDON EXISTING 15" STORM DRAIN OR REMOVE AS NECESSARY. EXISTING 18" RCP STORM SEWER PROPOSED 4' Ø STORM (MH-A) TRENCH DRAIN ABOVE STRUCTURE (BY OTHERS). ROUTED TO SFV-WEST PATIO DRAIN, TYP SIZE AND LOCATIONS TO BE DETERMINED PRIOR TO BUILDING PERMIT. PATIO INLET ABOVE STRUCTURE (BY OTHERS) PROPOSED 4' Ø STORM (MH-B) PROPOSED 4' Ø STORM (MH-C) PROPOSED AREA INLET #7 W/ LOCKABLE GRATE EXISTING 18" RCP STORM SEWER NEW COA STORM DRAIN CURB INLET NEW COA STORM DRAIN CURB INLET REMOVE EXISTING STORM DRAIN INLET AND REPLACE WITH NEW CUSTOM COA STORM DRAIN CURB INLET OVER EXISTING STORM LINE 6" AREA INLET PROPOSED 4' Ø STORM MH TO SERVE AS INLET @ SUMP (MH-D) PROPOSED STORM INLET #8. CONCRETE STRUCTURE w/ LOCKABLE GRATE. PROPOSED SUMP INLET #6 W/ CONC. WINGWALLS & LOCKABLE GRATE. EAST ONSITE STORM PIPE TO COLLECT ROOF DRAINS, PATIO DRAINS AND DOWNSPOUTS. SIZE AND LOCATIONS TO BE DETERMINED PRIOR TO BUILDING PERMIT. WEST ONSITE STORM PIPE TO COLLECT ROOF DRAINS, PATIO DRAINS AND DOWNSPOUTS. SIZE AND ALIGNMENT TO BE CONFIRMED PRIOR TO BUILDING PERMIT.AREA INLET (TYPICAL) SIZE TO BE CONFIRMED PRIOR TO BUILDING PERMIT. MOUNTAIN ROAD SWALE CONNECT PROPOSED STORM DRAIN TO EXISTING MANHOLE ABANDON EXISTING AREA INLET STRUCTURE & RESET GRATE OVER PROPOSED INLET STRUCTURE TRENCH DRAIN (ABOVE STRUCTURE) SLOT DRAIN ALONG TOP BACK OF CURB CONNECT SLOT DRAIN. PROVIDE CLEANOUT UPSTREAM OF CONNECTION 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 20 8010 NORTH DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 1 7 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 4 . 0 2 - C . 4 . 0 6 S T O R M P & P 1 5 1 0 1 . 0 6 . d w g CJB JKS C.4.02 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R CONCEPTUAL MASTER DRAINAGE PLAN 10/10/20191 SD PRICING SET 1.PROPOSED CONTOURS ARE AT 2' INTERVALS, EXISTING CONTOURS ARE AT 2' INTERVALS. 2.PIPE LENGTHS MEASURED FROM INSIDE OF STRUCTURE TO INSIDE OF STRUCTURE OR FITTING TO FITTING. 3.ALL ONSITE STORM PIPES TO BE SDR-35 GASKETED PVC PIPE OR AS NOTED ON PLANS. ALL STORM PIPES WITHIN THE ROW SHALL BE REINFORCED CONCRETE PIPE. 4.ALL LANDSCAPE AND OVERFLOW INLETS SHALL BE STANDARD GRATES (BLACK) OR AS NOTED ON PLANS WITH NYLOPLAST DRAIN BASINS OR PRE-APPROVED EQUIVALENT. 5.ALL GUTTER INLETS SHALL BE NEENAH 3462-B; VALLEY PAN INLETS WITHIN THE ROW SHALL BE NEENAH R-3359; 6.PROVIDE CLEANOUTS AT ALL DOWNSPOUT LOCATIONS THAT ARE ROUTED TO UNDERGROUND STORM PIPE. 7.0.5% MINIMUM ALLOWABLE LONGITUDINAL SLOPE FOR ALL DRAIN LINES. 8.CONTRACTOR TO ADHERE TO ALL MANUFACTURER'S INSTALLATION RECOMMENDATIONS. DRAINAGE NOTES: PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE6''WL 16''W 16''W 16''W PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UE FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING ELEC, TELE, CABLE, GASXETGC EXISTING GAS XETC XETC EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE EXISTING ELEC, TELE, CABLE XUT XUT XEL XEL XTV XTV XSA XSA LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW 3-2-20203 DETAILED REVIEW >>>>> > > > > > > > > > > > > > >> > > > > > > > > >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > > > > > > > > > > > > > > > uu XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XS D XS D > > XSD XSD XSD XS D 4" RIGID PERF. PIPE W/ 6" MIN. CDOT #67 AGGREGATE 18" SAND MEDIA + DEBRIS SCREEN DEBRIS SCREEN (3 4" WASHED SCREENED ROCK) 6" WIDE SEPARATOR WALL 2' MIN 1.00' FINISHED GRADE 6" WIDE BAFFLE WALL INLET PIPE7' MIN 24" SOLID MANHOLE LID & CASTING, TYP CENTERED OVER CLEANOUT WHERE APPLICABLE OVERFLOW WEIR BAFFLE WQCV EXTEND UNDERDRAIN & INSTALL END CAP DISCHARGE PIPE UNDERDRAIN CLEANOUT WITH CAP NORTH DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 3 5 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 4 . 0 0 - C . 4 . 0 1 - C . 4 . 0 3 - D R N B A S I N S . d w g C.4.03 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R WATER QUALITY TREATMENT PLAN 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 20 8010 JPP JKS 10-10-20191 SD PRICING 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW ASPEN S T R E E T STORM MH 'B' EAST STORM MH 'C' (DP#J-03) EAST STORM MH 'D' SERVES AS SUMP INLET FOR COLLECTION OF OFFSITE FLOWS STORM INLET #1 & #4 WEST W.Q. VAULT EAST W.Q. VAULT EAST ONSITE SITE STORM PIPES & INLETS (FINAL SIZE & LOCATION TO BE DETERMINED PRIOR TO BUILDING PERMIT APPLICATION) WATER QUALITY LEGEND EAST WATER QUALITY AREA WEST WATER QUALITY AREA STORM MH 'A' CONCEPTUAL WATER QUALITY SUMMARY PROJECT NUMBER:15101.06 NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. SAND FILTER VAULT TYPICAL DETAIL NOTES: 1.STORMWATER ROUTING OF ROOF DRAINS TO BE CONFIRMED @ BUILDING PERMIT SUBMISSION WITH FINAL WATER QUALITY TREATMENT VAULT DESIGN. 2.WATER QUALITY TREATMENT VOLUMES ARE CONSIDERED CONCEPTUAL. FINAL DESIGN AND DETAILS WILL BE PROVIDED IN SUPPORT OF BUILDING PERMIT APPLICATION TRENCH DRAIN TRENCH DRAIN SLOT DRAIN ALONG TOP BACK OF MOUNTABLE CURB VALLEY PAN INLET ISLAND INLET EXISTING INLET (OS5) TO REMAIN DE-01 DE-02POST S. ASPEN STREET BASIN WEST OFFSITE SWALE WEST ONSITE SITE STORM PIPES & INLETS (FINAL SIZE & LOCATION TO BE DETERMINED PRIOR TO BUILDING PERMIT APPLICATION) 3-2-20203 DETAILED REVIEW XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XGAS XGAS XE L XE L XE L XE L XE L X E L X E L XE L XEL XEL XEL XEL XEL XEL XEL XEL XELXELXELXELXELXELXEL XEL XEL XEL XELXELXELXELXELXELXELXELXEL XU T XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUT XUTXG A S XE L XE L XE L XE L XE L XE L XE L XE L XW L XW L X G A S X G A S XS A XS A XS A XSAXSAXSA XS A X S A X S A XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSD XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XSA XWL XWL XWL XWL XWL XWL XW L XW L XW L XW L XGAS XGAS X G A S X G A S X G A S X G A S X G A S XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGA S XGA S XETC XETC XETC XETC XETC XETC XETC XETC XETC XSD XSD XSD XSD XSD XSD XSD XS D XS D XT V XT V XT V XT V XT V XUT XUT XUT XUT XUT XUT XUT XUT XSD XUTXUTXUT X G A S XT V XT V XUT XUT XUT XUT XUT XUT XUT XUT XGASXGASXGASXGASXGASXGASXGASXGAS X G A S X G A S XE L XE L X E L TC TC TC TC TC TC TC TC TC TC TC 16 ' ' WL 16 ' ' WL 16 ' ' WL UE L U E L U E L U E L GA S G A S G A S G A S GA S S A N GAS GAS GAS GAS GAS G A S G A S GAS GAS GAS GAS GAS GAS GAS GAS UE L UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UEL UE L UEL UEL UEL UEL UEL UEL UEL UEL 8'' SA 8'' SA 8'' DS 16'' WL TE L T E L T E L T E L TE L TE L TE L 9+95 10+00 10+25 10+50 10+7 5 11+0 0 11+25 11+50 11+60 EXISTING STORM INLET SAS-13 RIM= 7992.63' INV. IN (E) 15" PVC = 7986.60' INV. OUT (N) 18" RCP = 7980.15' 8000 EA S T S T O R M S E W E R R E : S H E E T C . 4 . 0 2 EXISTING UTILITIES TO BE ABANDONED OR RE-ROUTED. RE: MASTER UTILITY PLAN C.3.00 6" PVC STORM DRAIN NEW STORM INLET #3 (RE-INSTALL INLET GRATE FROM ABANDONED INLET STRUCTURE NEENAH R-4895-2) STA:11+59.15 RIM:8007.20 18" R.C.P. INV OUT:7998.65 SUMP:7998.15 NEW COA STORM DRAIN INLET #2 (REMOVE EXISTING STORM DRAIN INLET AND REPLACE WITH NEW CUSTOM COA STORM DRAIN CURB INLET OVER EXISTING STORM LINE) STA:10+36.45 RIM:7994.74 FLOWLINE:7995.24 EX. 18" R.C.P. INV IN:7984.74 EX. 18" R.C.P. INV OUT:7984.65 SUMP:7984.15 PIPE-1 37.7' of 18" R.C.P. @ 9.00% EX PIPE-2 33.4' of 18" R.C.P. @ 19.25% REPLACE EXISTING CURB INLET WITH NEW COA STORM DRAIN INLET #4 STA:20+01.75 RIM:7988.39 FLOWLINE:7988.89 18'' R.C.P. INV IN:7980.00 EX. 18" Reinforced Concrete Pipe INV OUT:7979.80 SUMP:7979.30 4'Ø STORM MH-A STA:20+48.11 RIM:7996.80 18'' R.C.P. INV IN:7984.20 6'' PVC INV IN:7991.53 18'' R.C.P. INV OUT:7983.00 SUMP:7982.50 PIPE-2 43.6' of 18" R.C.P. @ 6.92% NEW COA STORM DRAIN INLET #1 STA:20+01.78 RIM:7988.80 FLOWLINE:7989.30 EX 18" R.C.P. INV IN:7978.40 EX 18" R.C.P. INV OUT:7977.60 SUMP:7977.10 PIP E - 8 42 . 8 ' o f 6 " P . V . C . @ 3 . 3 8 % PROPOSED SITE WALLS PROPOSED GAS XING STA:11+43.69 EXISTING STORM MANHOLE (CONNECT PROPOSED STORM DRAIN TO EXISTING MANHOLE) STA:20+48.11 RIM:8000.20 LOWER RIM AS REQUIRED 18'' R.C.P. INV IN:7995.29 EX. 18'' R.C.P. INV OUT:7995.09 SUMP:7994.59 EXISTING INLET (OS5) TO REMAIN STA:10+67.85 RIM:7999.78 EX. 18'' R.C.P. INV IN:7989.77 EX. 18'' R.C.P. INV OUT:7989.96 EX PIPE-1 64.4' of 18" Reinforced Concrete Pipe @ 19.25% EX PIPE-329.1' of 18" R e i n f o r c e d C o n c r e t e P i p e @ 1 8 . 3 7 % EX P I P E - 4 45.2 ' o f 1 8 " R e i n f o r c e d C o n c r e t e P i p e @ 1 1 . 8 2 % EXISTING INLET STRUCTURE TO BE ABANDONED. EXISTING INLET GRATE TO BE USED ON NEW INLET STRUCTURE #3 GH-WEST PROFILE 7970 7980 7990 8000 8010 8020 8030 10+00 79 8 9 . 1 79 8 8 . 9 6 79 9 2 . 9 79 9 2 . 8 0 10+50 79 9 6 . 9 79 9 7 . 4 6 80 0 0 . 5 79 9 9 . 9 9 11+00 80 0 2 . 1 80 0 0 . 6 6 80 0 3 . 7 80 0 0 . 2 2 11+50 80 1 5 . 4 80 0 8 . 4 5 11+60 80 1 5 . 5 80 0 7 . 2 0 EXISTING 8" SEWER SERVICE CROSSING (FROM SHADOW MNT. TOWNHOMES) STA: 10+82.45 INV= 7994.78' (TO REMAIN) PROPOSED TELE, CABLE STA: 10+47.73 T.O.P.= 7994.15' PROPOSED SITE WALLS (BY OTHERS) 1.99 PIPE-1 37.7' of 18" R.C.P. @ 9.00% PROPOSED GRADE EXISTING GRADE PROPOSED GRADEEXISTING GRADE HORIZ. SCALE: 1 = 10' VERT. SCALE: 1 = 10' REPLACE EXISTING CURB INLET WITH NEW COA STORM DRAIN INLET #2 STA:10+36.45 RIM:7994.74 FLOWLINE:7995.24 EX. 18" R.C.P. INV IN:7984.74 EX. 18" R.C.P. INV OUT:7984.65 SUMP:7984.15 NEW STORM INLET #3 STA:11+59.15 RIM:8007.20 18" R.C.P. INV OUT:7998.65 SUMP:7998.15 STA: 10+82.45 INV.= 7991.27' EX PIPE-2 33.4' of 18" R . C . P . @ 1 9 . 2 5 % NEW COA STORM DRAIN INLET #1 STA:20+01.78 RIM:7988.80 FLOWLINE:7989.30 EX. 18" R.C.P. INV IN:7978.40 EX. 18" R.C.P. INV OUT:7977.60 SUMP:7977.10 ANTICIPATED WALL FOOTER 4.00 4.00 PROPOSED GAS STA: 11+43.69 T.O.P.= 8002.51' EXISTING STORM MANHOLE STA:20+48.11 RIM:8000.20 (LOWER RIM AS REQUIRED) 18'' R.C.P. INV IN:7995.29 EX. 18'' R.C.P. INV OUT:7995.09 SUMP:7994.59 EXISTING INLET (OS5) TO REMAIN STA:10+67.85 RIM:7999.78 EX. 18'' R.C.P. INV IN:7989.77 EX. 18'' R.C.P. INV OUT:7989.96 SUMP:7989.77 EX PIPE-3 29.1' of 18" R e i n f o r c e d C o n c r e t e P i p e @ 1 8 . 3 7 % EX PIPE-4 45.2' of 18" Reinfo r c e d C o n c r e t e P i p e @ 1 1 . 8 2 % STA: 10+69.83 INV.= 7990.21' NORTH 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 010 10 20 10 405 DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 3 : 0 8 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 4 . 0 2 - C . 4 . 0 6 S T O R M P & P 1 5 1 0 1 . 0 6 . d w g CJB JKS C.4.04 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R WEST STORM PIPE PROFILE 10/10/20191 SD PRICING SET 1.PROPOSED CONTOURS ARE AT 2' INTERVALS, EXISTING CONTOURS ARE AT 2' INTERVALS. 2.PIPE LENGTHS MEASURED FROM INSIDE OF STRUCTURE TO INSIDE OF STRUCTURE OR FITTING TO FITTING. 3.ALL ONSITE STORM PIPES TO BE SDR-35 GASKETED PVC PIPE OR AS NOTED ON PLANS. ALL STORM PIPES WITHIN THE ROW SHALL BE REINFORCED CONCRETE PIPE. 4.ALL LANDSCAPE AND OVERFLOW INLETS SHALL BE STANDARD GRATES (BLACK) OR AS NOTED ON PLANS WITH NYLOPLAST DRAIN BASINS OR PRE-APPROVED EQUIVALENT. 5.ALL GUTTER INLETS SHALL BE NEENAH 3462-B; VALLEY PAN INLETS WITHIN THE ROW SHALL BE NEENAH R-3359; 6.PROVIDE CLEANOUTS AT ALL DOWNSPOUT LOCATIONS THAT ARE ROUTED TO UNDERGROUND STORM PIPE. 7.0.5% MINIMUM ALLOWABLE LONGITUDINAL SLOPE FOR ALL DRAIN LINES. 8.CONTRACTOR TO ADHERE TO ALL MANUFACTURER'S INSTALLATION RECOMMENDATIONS. DRAINAGE NOTES: NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE6''WL 16''W 16''W 16''W PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UE FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING ELEC, TELE, CABLE, GASXETGC EXISTING GAS XETC XETC EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE EXISTING ELEC, TELE, CABLE XUT XUT XEL XEL XTV XTV XSA XSA LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW WEST STORM PIPE WEST STORM PIPE PROFILE S. ASPEN STREET 3-2-20203 DETAILED REVIEW X S A X S A X S A X S A X S A XG A S XE L XEL XEL XE L XEL XEL X U T XU T X U T X U T X U T X U T x x x x x X S D X S D X S D X S D X S D X S D X S D X S D X S D XE L XE L X E L XEL XEL XE L XE L XE L XE L XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL XUT XUT XUT XU T XU T XUT XU T XU T X U T XUT XUT XUT XUT XUT XUT XUT X U T XU T XU T XE L XE L X E L X E L X E L X E L XE L XEL XEL XEL XEL XEL XEL XEL XEL XEL XEL X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L X E L XE L XE L XE L XE L XE L XE L XE L XE L XE L XE L XE L X E L X E L X E L X E L X E L XE L XE L XE L XE L XE L XE L XE L XE L X U T X U T X U T X U T X U T X U T XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS XGAS X G A S X G A S XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XWL XW L XW L X W L XW L X W L XW L X W L XW L X W L X W L XW L XU T XU T XU T X W L XS D XS D XS D XS A XS A XS A XS A XS A XS A XS A XS A XS A XS A XWL XWL XG A S XG A S XGA S XGA S XGA S XGA S XGA S X G A S X G A S X G A S X G A S XE T C XE T C XE T C XE T C X S D X S D S T XSD XSD XSD XSD XGAS WL SV C WL SV C WL SV C WL SV C WL T C T C T C 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 16'' WL 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L 1 6 ' ' W L UEL UEL UEL UEL UEL ET ET ET ET ET ET ET ET ET ET ET ET ET E T E T E T E T E T E T E T E T GAS GAS G A S G A S G A S G A S G A S G A S G A S GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS G A S G A S G A S GA S GA S GA S GA S SANG A S G A S GA S UE L UE L SAN 8'' SA 8'' SA 8'' SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8'' SA 8'' SA 8'' SA 8'' SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' SAN TEL TEL TEL TEL TEL 20 + 0 0 20 + 2 5 20+50 20+75 21+00 21+25 21+50 21+75 2 2 + 0 0 2 2 + 2 5 2 2 + 5 0 0 + 0 0 0+ 5 0 0+ 6 3 0+ 0 0 0+ 3 2 WATER SERVICE CROSSING STA:20+93.32 (GH-WEST) SEWER SERVICE CROSSING STA:21+96.33 (GH-WEST) 8" SEWER SVC CROSSING STA:0+11.67 (SFV WEST) 8" SEWER SVC. CROSSING STA:0+08.76 (SFV EAST) 80 0 0 80 0 0 WEST WQ VAULT EAST WQ VAULT LIMITS OF PROPOSED BELOW GRADE STRUCTURE REPLACE EXISTING CURB INLET WITH NEW COA STORM DRAIN INLET #4 STA:20+01.75 RIM:7988.39 FLOWLINE:7988.89 18'' R.C.P. INV IN:7980.00 EX. 18" Reinforced Concrete Pipe INV OUT:7979.80 SUMP:7979.30 4'Ø STORM MH-A STA:20+48.11 RIM:7996.80 18'' R.C.P. INV IN:7984.20 6'' PVC INV IN:7991.53 18'' R.C.P. INV OUT:7983.00 SUMP:7982.50 4'Ø STORM MH-C STA:21+85.98 RIM:7997.40 18'' HDPE INV IN:7987.20 10'' PVC INV IN:7987.68 18'' R.C.P. INV OUT:7987.00 SUMP:7986.50 4' ∅ STORM MH-D W/ OPEN GRATE STA:22+23.68 RIM:7996.00 15'' HDPE INV IN:7991.00 18'' HDPE INV OUT:7990.80 SUMP:7990.30 PI P E - 2 43 . 6 ' o f 1 8 " R . C . P . @ 6 . 9 2 % 4'Ø STORM MH-B STA:21+34.78 RIM:7997.83 18'' R.C.P. INV IN:7986.05 10'' PVC INV IN:7986.72 18'' R.C.P. INV OUT:7985.85 SUMP:7985.35 PIPE-382.7' of 18" R.C.P. @ 2.00% PIPE-447.2' of 18" R.C.P. @ 2.00% P I P E - 5 3 4 . 1 ' o f 1 8 " H D P E . @ 1 0 . 6 8 % 9 7 . 2 ' o f 1 6 " H D P E @ 9 . 2 9 % P I P E - 9 1 4 . 1 ' o f 1 0 " P . V . C . @ 1 2 . 0 4 % NEW STORM INLET #9 COA STORM DRAIN INLET WITH VALLEY PAN GRATE STA:0+61.11 RIM:7998.20 10" P.V.C. INV OUT:7994.00 SUMP:7993.50 PI P E - 1 0 27 . 7 ' o f 1 0 " P . V . C . @ 1 . 9 9 % WEST QUALITY TREATMENT VAULT STA:0+23.89 TOP OF LID:7996.05 FG:7998.05 10" P.V.C. INV IN:7993.45 10" P.V.C. INV OUT:7988.39 EAST QUALITY TREATMENT VAULT STA:0+23.91 TOP OF LID:7995.62 FG:7996.68 10" P.V.C. INV OUT:7987.95 PI P E - 1 1 13 . 8 ' o f 1 0 " P . V . C . @ 2 . 0 0 % NEW STORM DRAIN INLET #5 6" AREA INLET STA:20+89.30 RIM:7998.00 6" P.V.C. INV OUT:7993.00 SUMP:7992.50 PIP E - 8 42. 8 ' o f 6 " P . V . C . @ 3 . 3 8 % 0 + 0 0 0+4 6 PROPOSED GAS XING STA:0+16.93 (MH-A TO INLET #5) PROPOSED ELEC XING STA:0+12.07 (MH-A TO INLET #5) 8" SEWER SVC CROSSING STA:0+42.49 (SFV WEST) RIM:7998.01' RIM:7998.08' RIM:7998.18' RIM:7996.86' RIM:7996.84' RIM:7997.13' WATER MAIN CROSSING STA:20+38.99 (GH-WEST) PROPOSED GAS XING STA:0+09.67 (SFV EAST) PROPOSED GAS XING STA:0+06.30 (SFV WEST) PROPOSED TELE XING STA:20+43.36 (GH-WEST) PROPOSED ELEC XING STA:20+67.48 (GH-WEST) TRENCH DRAIN INTERNAL ROUTING, CONNECT TO EAST WQ VAULTEXISTING STORM MANHOLE (CONNECT PROPOSED STORM DRAIN TO EXISTING MANHOLE) STA:20+48.11 RIM:8000.20 LOWER RIM AS REQUIRED 18'' R.C.P. INV IN:7995.29 EX. 18'' R.C.P. INV OUT:7995.09 SUMP:7994.59 RIM:7996.0' SLOT DRAIN ALONG BACK OF CURB GH-EAST PROFILE 7970 7980 7990 8000 8010 20+00 79 8 8 . 6 79 8 8 . 6 4 79 9 2 . 7 79 9 2 . 7 4 20+50 79 9 7 . 1 79 9 6 . 7 8 79 9 9 . 6 79 9 7 . 2 1 21+00 80 0 2 . 1 79 9 7 . 3 7 80 0 0 . 3 79 9 7 . 4 1 21+50 79 9 9 . 0 79 9 7 . 3 9 79 9 8 . 0 79 9 7 . 0 8 22+00 80 0 1 . 6 79 9 7 . 7 6 80 0 9 . 1 79 9 6 . 5 7 22+50 80 0 9 . 7 80 0 1 . 3 9 7990 7980 8010 8000 STA: 20+38.99 UTILITY XING 16" WATER MAIN T.O.P.= 7987.98'STA: 21+96.33 UTILITY XING 8" RUTHIES SEWER SERVICE INV.= 7991.41' STA: 21+96.33 INV.= 7988.09' STA: 20+93.32 INV.= 7985.06' HORIZ. SCALE: 1 = 10' VERT. SCALE: 1 = 10' REPLACE EXISTING CURB INLET WITH NEW COA STORM DRAIN INLET #4 STA:20+01.75 RIM:7988.39 FLOWLINE:7988.89 18'' R.C.P. INV IN:7980.00 18'' R.C.P. INV OUT:7979.80 SUMP:7979.30 4'∅ STORM MH-D W/ OPEN GRATE STA:22+23.68 RIM:7996.00 15'' HDPE INV IN:7991.00 18'' HDPE INV OUT:7990.80 SUMP:7990.30 PIPE-5 34.1' of 18" HDPE @ 1 0 . 6 8 % 4'Ø STORM MH-C STA:21+85.98 RIM:7997.40 18'' HDPE INV IN:7987.20 10'' PVC INV IN:7987.68 18'' R.C.P. INV OUT:7987.00 SUMP:7986.50 PIPE-4 47.2' of 18" Reinforced Concrete Pipe @ 2.00% 4'Ø STORM MH-B STA:21+34.78 RIM:7997.83 18'' R.C.P. INV IN:7986.05 10'' PVC INV IN:7986.72 18'' R.C.P. INV OUT:7985.85 SUMP:7985.35 PIPE-3 82.7' of 18" Reinforced Concrete Pipe @ 2.00% 4'Ø STORM MH-A STA:20+48.11 RIM:7996.80 18'' R.C.P. INV IN:7984.20 6'' PVC INV IN:7991.53 18'' R.C.P. INV OUT:7983.00 SUMP:7982.50 PIPE-2 43.6' of 18" Reinforced Concr e t e P i p e @ 6 . 9 2 % 1.78 1.52 STA: 20+93.32 UTILITY XING 6" WATER SERVICE T.O.P.= 7988.87' STA: 20+38.99 INV.= 7982.54' 1.76 PIPE-6 97.2' of 16" HDPE @ 9 . 2 9 % PROPOSED GRADEEXISTING GRADE PROPOSED TELE STA: 20+43.36 T.O.P.= 7991.91' PROPOSED ELECTRIC STA: 20+67.48 T.O.P.= 7993.16' SFV-WEST PROFILE 7980 7990 8000 8010 7980 7990 8000 8010 -0+05 0+00 79 9 9 . 8 79 9 7 . 7 6 80 0 3 . 1 79 9 8 . 0 3 0+50 80 0 4 . 3 79 9 8 . 2 1 0+81 SFV-EAST PROFILE 7980 7990 8000 8010 7980 7990 8000 8010 -0+05 0+00 79 9 8 . 2 79 9 7 . 3 6 79 9 6 . 6 5 0+45 7' MIN.7' MIN. 1.00'2.00' STA: 0+42.58 INV.= 7993.66' PROPOSED 8" SEWER SVC STA: 0+42.58 INV.= 7989.93' 8" SEWER SVC. STA: 0+08.76 INV.= 7991.26' STA: 0+11.59 INV.= 7987.88' STA: 0+08.76 INV.= 7987.81' HORIZ. SCALE: 1 = 10' VERT. SCALE: 1 = 10' HORIZ. SCALE: 1 = 10' VERT. SCALE: 1 = 10' MH-A TO INLET #5 PROFILE 7980 7990 8000 8010 7980 7990 8000 8010 PROPOSED 8" SEWER SVC STA: 0+11.59 INV.= 7990.29' PROPOSED GAS STA: 0+06.32 INV.= 7994.99' NEW STORM INLET #9 COA STORM DRAIN INLET WITH VALLEY PAN GRATE STA:0+61.11 RIM:7998.20 10'' PVC INV OUT:7994.00 SUMP:7993.50 PIPE-10 27.7' of 10" P.V.C. @ 1.99% WEST QUALITY TREATMENT VAULT STA:0+23.89 TOP OF LID:7996.05 FG:7998.05 10'' PVC INV IN:7993.45 10'' PVC INV OUT:7988.39 PIPE-9 14.1' of 10" P.V.C. @ 12.04% 4'Ø STORM MH-B STA:21+34.78 RIM:7997.83 18'' R.C.P. INV IN:7986.05 10'' PVC INV IN:7986.72 18'' R.C.P. INV OUT:7985.85 SUMP:7985.35 4'Ø STORM MH-C STA:21+85.98 RIM:7997.40 18'' HDPE INV IN:7987.20 10'' PVC INV IN:7987.68 18'' R.C.P. INV OUT:7987.00 SUMP:7986.50 EAST QUALITY TREATMENT VAULT STA:0+23.91 TOP OF LID:7995.62 FG:7996.68 10'' PVC INV OUT:7987.95 PIPE-11 13.8' of 10" P.V.C. @ 2.00% PROPOSED GAS STA: 0+09.67 INV.= 7994.30' PROPOSED GRADEEXISTING GRADE 1.54 3.03 2.57 0+00 79 9 6 . 7 79 9 6 . 7 3 79 9 7 . 5 79 9 7 . 4 8 0+46 79 9 8 . 0 79 9 8 . 0 0 PROPOSED GAS STA: 0+16.93 T.O.P.= 7994.44' PROPOSED ELECTRIC STA: 0+12.07 T.O.P.= 7993.38' 4'Ø STORM MH-A STA:20+48.11 RIM:7996.80 18" R.C.P. INV IN:7984.20 6" R.C.P. INV IN:7991.53 18" R.C.P. INV OUT:7983.00 SUMP:7982.50 NEW STORM DRAIN INLET #5 6" AREA INLET STA:20+89.30 RIM:7998.00 6'' PVC INV OUT:7993.00 SUMP:7992.50 PIPE-8 42.8' of 6" P.V.C. @ 3.38% HORIZ. SCALE: 1 = 10' VERT. SCALE: 1 = 10' N O R T H DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 3 : 1 3 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 4 . 0 2 - C . 4 . 0 6 S T O R M P & P 1 5 1 0 1 . 0 6 . d w g CJB JKS C.4.05 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R EAST STORM PIPE PROFILE 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 010 10 20 10 405 10/10/20191 SD PRICING SET STA 20+00 - 22+50 MATCH LINE STA: 22+50 SEE SHEET C.4.06 MA T C H L I N E S T A : 2 2 + 5 0 SE E S H E E T C . 4 . 0 6 NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. PROPOSED ELECTRIC MANHOLE PROPOSED DRAINAGE DRY-WELL PROPOSED SEWER MANHOLE PROPOSED FIRE HYDRANT PROPOSED WATER VALVE PROPOSED GAS METER/VALVE PROPOSED ELECTRIC TRANSFORMER PROPOSED ELECTRIC METER PROPOSED CATV PEDESTAL PROPOSED SEWER CLEANOUT PROPOSED LIGHT POLE PROPOSED SIGN PROPOSED STORM INLET PROPOSED 6" WATER SERVICE6''WL 16''W 16''W 16''W PROPOSED 8" SANITARY SEWER MAIN PROPOSED GAS TC GAS PROPOSED UNDERGROUND ELECTRIC PROPOSED FIBER OPTIC PROPOSED STORM SEWER PROPOSED TELE & CABLE UE FO FO 8''SA PROPOSED 16" WATER MAIN EXISTING ELECTRIC MANHOLE EXISTING DRAINAGE DRY-WELL EXISTING SEWER MANHOLE EXISTING TELEPHONE MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING CURB STOP EXISTING GAS METER EXISTING ELECTRIC TRANSFORMER EXISTING ELECTRIC METER EXISTING TELEPHONE PEDESTAL EXISTING CATV PEDESTAL EXISTING STORM INLET EXISTING STORM SEWER EXISTING EASEMENT EXISTING PROPERTY LINE EXISTING SETBACK (XX')STBK EXISTING WATER MAINXWLXWL EXISTING SANITARY SEWER MAIN EXISTING ELEC, TELE, CABLE, GASXETGC EXISTING GAS XETC XETC EXISTING TELEPHONE XGAS XGAS EXISTING UNDERGROUND ELECTRIC EXISTING CABLE EXISTING ELEC, TELE, CABLE XUT XUT XEL XEL XTV XTV XSA XSA LEGEND: PROPOSED UTILITIES SAN DRY WELL LEGEND: EXISTING UTILITIES PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW 3-2-20203 DETAILED REVIEW XSD XSD XSD XSD XSD ST XUT X E L X E L X E L XEL XWL XWL XWL XUT XUT XUT XUT XUT X U T X U T X U T X U T X U T X U T X U T X U T XU T X U T XU T XUT XUT XUT XUT XUT XU T XU T XU T XUT XUT XUT XUT XUT XUT XUTXUTXUT X E L XWL XW L XWL XW L XW L XW L XW L XW L XW L XWLXWLXWLXWLXWLXWLXWLXWLXWLXWLXWLXWLXWLXWLXWLXWLXWL XWL XWL XWL XWL 6" CIP 16'' WL 16'' WL 16'' WL 16'' WL 16 ' ' WL 16 ' ' WL 16 ' ' 6''WL 6''WL 6''WL 6''WL 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8''SA 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' S A 8 ' ' ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET E T E T E T E T GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GA S GA S G A S G A S G A S G A S G A S GAS GAS SW I T C H GE A R RE C L O S E R XF R M R SA N SA N SA 8''SA 8''SA 8''SA 4 ' ' W L 4 ' ' W L UE L UEL UEL UEL UE L UE L UE L UE L UEL U E L 6''WL 6''WL6''WL6''WL6''WL6''WL 6'' WL 6'' W L 6'' WL UEL 22+50 22+75 23+00 23+25 23+50 23+75 24+00 24+25 24+50 24+7524+77 RUTHIE'S SEWER SERVICE CROSSING STA:23+22.30 OFF:-12.85L SEWER INV.=8004.57 STORM INV.=8001.30 8 0 1 0 8 0 2 0 8 0 3 0 80 4 0 ABANDON EXISTING INLET AND HEADWALL & STORM PIPE 8040 8030 8020 MOUNTAIN QUEEN CONDOS EX. FIRE ACCESS & DRAINAGE EASEMENT EASEMENT TO REMAIN NEW STORM INLET #6 STA:23+23.49 RIM:8007.22 8'' HDPE INV IN:8001.03 12'' HDPE INV IN:8000.20 15'' HDPE INV OUT:8000.00 SUMP:7999.50 NEW STORM INLET #8 STA:24+75.26 RIM:8037.00 8'' HDPE INV OUT:8033.00 SUMP:8032.50 PIPE-6 97.4' of 16" HDPE @ 9.29% PIPE-7153.3' of 8" H D P E @ 2 1 . 4 2 % NEW AREA INLET #7 STORM INLET WITH CONCRETE HEADWALL STA:23+21.50 OFFSET:-35.72L RIM:8008.00 12'' HDPE INV OUT:8003.41 SUMP:8002.91 PI P E - 6 A 33 . 9 ' o f 1 2 " H D P E @ 9 . 5 9 % 7970 7980 7990 8000 8010 8020 8030 8040 8050 8060 22+50 80 0 9 . 7 80 0 1 . 3 9 80 1 1 . 9 80 0 4 . 4 4 23+00 80 1 4 . 7 80 0 6 . 4 0 80 1 6 . 5 80 0 7 . 5 1 23+50 80 1 8 . 3 80 1 1 . 4 8 80 2 3 . 1 80 1 6 . 5 3 24+00 80 2 7 . 1 80 2 1 . 6 9 80 3 1 . 3 80 2 6 . 8 5 24+50 80 3 5 . 4 80 3 2 . 0 1 80 3 9 . 0 80 3 6 . 9 4 24+77 80 3 9 . 2 80 3 7 . 5 2 7990 8040 7980 8010 8000 8020 8030 8050 HORIZ. SCALE: 1 = 10' VERT. SCALE: 1 = 10' NEW STORM INLET #8 STA:24+75.26 RIM:8037.00 8'' HDPE INV OUT:8033.00 SUMP:8032.50 PIPE-7 153.3' of 8 " H D P E @ 2 1 . 4 2 % NEW STORM INLET #6 STA:23+23.49 RIM:8007.22 8'' HDPE INV IN:8001.03 12'' HDPE INV IN:8000.20 15'' HDPE INV OUT:8000.00 SUMP:7999.50 PIPE-6 97.4' of 16" HDPE @ 9. 2 9 % PROPOSED GRADEEXISTING GRADE NO R T H DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 5 , 2 0 2 0 - 3 : 1 9 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 4 . 0 2 - C . 4 . 0 6 S T O R M P & P 1 5 1 0 1 . 0 6 . d w g CJB JKS C.4.06 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 MEMBER UTILITIES FOR THE MARKING OF UNDERGROUND BEFORE YOU DIG, GRADE, OR EXCAVATE CALL 2-BUSINESS DAYS IN ADVANCE Know what's below. before you dig.Call R 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 010 10 20 10 405 EAST STORM PIPE PROFILE STA 22+50 - END 10/10/20191 SD PRICING SET MA T C H L I N E S T A : 2 2 + 5 0 SE E S H E E T C . 4 . 0 5 MA T C H L I N E S T A : 2 2 + 5 0 SE E S H E E T C . 4 . 0 5 NOTE: 1.THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW 3-2-20203 DETAILED REVIEW 12" 24" TYP. 24" TYP. BACKFILL WITH ONSITE GRAVEL OR PITRUN COMPACTED TO 95% STANDARD PROCTOR STANDARD CAST IRON OR ALUM. MANHOLE STEPS PLACED AT MAX. 15" O.C. ORIENT STEPS TO ALIGN BENEATH ACCESS LID 6" PVC PERFORATED RISER PIPE WITH GOOSE NECK & WRAPPED IN FILTER FABRIC SEPARATOR FILTER FABRIC (TYP.) PRECAST CONCRETE LID SECTION WITH RUST RESISTANT ACCESS HATCH WITH LIFTING HANDLES 1 1 2"DIA. WASHED ROCK ATTACH FILTER FABRIC TO INSIDE OF PERFORATED BARREL SECTIONS CONCRETE GRADE BEAMS TO SUPPORT DRYWELL BARREL SECTIONS 4" OF 3 4" DIA. WASHED ROCK (CDOT #67 OR APPROVED EQUAL) PLACED UNDER STRUCTURE TO ACT AS A LEVELING COURSE GRADE RINGS, TYP. 24"Ø STEEL FRAME & ACCESS LID 12" MIN. SOIL COVER 5' INSIDE DIAMETER MEDIUM STREET TREE (TYP.) DEEPROOT UB18-2 ROOT BARRIER, TYP. BOTH SIDES TREE ROOTBALL PLANTING SOIL, TAMPED TO MAX. 85% COMPACTION BELOW ROOTBALL ANCHOR EACH SILVA CELL TO GROUND WITH (4) 10" SPIKE,<10MM DIA., SEE CELL BASE FOR SPIKE HOLE NON-WOVEN GEOTEXTILE (ADS 0801T, MIRAFI 180 N, GEOTEX 801 OR PRE-APPROVED EQUIVALENT) PLANTING SOIL PER SILVA CELL SPECIFICATIONS, INSTALLED IN 8" LIFTS (2 LIFTS PER CELL) 4" MIN. 3 4" MINUS ROCK; CDOT #67 OR APPROVED EQUAL SUB BASE, 3 PASSES WITH PLATE COMPACTORSUBGRADE BELOW GEOTEXTILE AND AGGREGATE BASE COURSE, COMPACTED TO 95% OR BY 3 PASSES WITH PLATE COMPACTOR, WHICHEVER IS GREATER ADJACENT CONCRETE SIDEWALK w/ TURNED DOWN EDGE TO REST ON FRAME OPEN LANDSCAPING; IE. NO TREE GRATE 2" (R-10) HIGH DENSITY RIGID INSULATION WRAP SILVA CELLS W/ GEOGRID (STRATAGRID SG 150, MIRAGRID 2XT, FORTRAC 35, SF 20 BIAXIAL OR PRE-APPROVED EQ. ZIP TIE GEOGRID TO SILVA CELL. PROVIDE A MINIMUM OF 12" OVERLAP ON TOP AND 6" ON BOTTOM HP 570 WOVEN GEOTEXTILE FABRIC. EXTEND 18" MIN. BEYOND EXCAVATION. 12" 12." MIN. SUBBASE: 4" MIN. 3 4" MINUS ROCK; CDOT #67 OR APPROVED EQUAL 4" INSPECTION RISER TO PROVIDE MONITORING OF SOIL MOISTURE; RE. TO INSPECTION RISER DETAIL THIS SHEET. DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 2 : 4 4 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 5 . 0 0 - C . 5 . 0 2 S I T E D E T A I L S . d w g CJB JKS C.5.00 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 SITE DETAILS NEW ASPHALT NOTES: 1.THE SAWCUT SHALL BE FULL DEPTH AND 12" MINIMUM FROM THE EXISTING EDGE OF ASPHALT. 2.THE DEPTH OF THE MILLING SHALL BE THE SAME AS THE THICKNESS OF THE TOP LIFT OF ASPHALT: 2" MINIMUM. 3.THE WIDTH OF THE MILLING AREA SHALL BE 12" MINIMUM, BUT CAN BE UP TO THE FULL WIDTH OF EXISTING ASPHALT. 4.WITHIN THROUGH LANES THE LONGITUDINAL SEAMS AT THE EDGES OF THE MILLED AREAS SHELL BE PARALLEL TO THE DIRECTION OF TRAVEL AND TRANSVERSE SEAMS AT THE ENDS OF THE MILLED AREAS SHALL BE PERPENDICULAR TO THE DIRECTION OF TRAVEL. APPLY TACK COAT EXISTING ASPHALT SAWCUT 2" MILLING 12" MIN VARIES SEE PLANS 2" HMA OVER 3" HMA. OR MATCH EXISTING THICKNESS, WHICHEVER IS GREATER SCALE: N.T.S. SHEER STEP ASPHALT PATCH DETAIL 6" 2" 4' REFER TO DETAIL 3/C6.0 FOR SUBGRADE PREP STL. REINFORCED; RE. TO NOTES NOTES: 1.CONCRETE MUST CONFORM TO CDOT CLASS D (MIN. 28-DAY COMPRESSIVE STRENGTH OF 4,500 PSI); 80% OF THIS STRENGTH TO BE ACHIEVED IN THE FIRST 7-DAYS. 2.CONCRETE SHALL CONTAIN FIBERMESH 300 PER OR APPROVED EQUIVALENT PER MANUFACTURER'S RECOMMENDATIONS. 3.RE. TO LANDSCAPE PLANS FOR SNOWMELT AREAS 4.RE. TO MECH. DWGS FOR SNOWMELT SYSTEM DESIGN 5.SNOWMELT CONCRETE TO INCLUDE STEEL REINFORCEMENT; RE. TO CONCRETE REINFORCEMENT NOTES 6.CONTRACTOR TO EXCAVATE EXISTING SUBGRADE AS REQUIRED TO ACCOMMODATE THE CONCRETE PAVEMENT SECTION. 7.6" AGGREGATE BASE COURSE SHALL BE PLACED UNDER CURB, MOISTURE TREATED TO WITHIN 2 PERCENT OF OF OPTIMUM MOISTURE CONTENT, AND COMPACTED TO AT LEAST 95% OF MAXIMUM MODIFIED PROCTOR DENSITY. 8.PLACEMENT AND COMPACTION OF AGGREGATE BASE COURSE SHALL BE OBSERVED AND TESTED BY THE PROJECT GEOTECHNICAL ENGINEER. PLACEMENT SHALL NOT COMMENCE UNTIL THE UNDERLYING SUBGRADE IS PROPERLY PREPARED AND TESTED. 9.THE SUBGRADE & BASE COURSE SHALL BE PROOF ROLLED AFTER THE REQUIRED COMPACTION HAS BEEN OBTAINED AND THE SUBGRADE HAS BEEN SHAPED TO THE REQUIRED CROSS SECTION. PROOF ROLLING SHALL BE PERFORMED IN ACCORDANCE WITH CDOT SPECIFICATIONS WITH A VEHICLE WITH A MINIMUM AXLE LOAD OF 18 kips PER AXLE AND OBSERVED BY PROJECT ENGINEER AND/OR PROJECT GEOTECHNICAL ENGINEER. REINFORCING NOTES: 1.REINFORCING BARS SHALL BE ASTM A-615 GRADE 60. 2.REINFORCEMENT BARS SHALL BE #4 AND SPACED 18-INCH ON CENTER BOTH WAYS (X & Y). 3.MAINTAIN A 2" MINIMUM CLEAR DISTANCE FROM EDGE OF BAR TO EDGE OF CONCRETE. 4.REINFORCING LAP SPLICES SHALL BE A MINIMUM OF 40 BAR DIAMETERS UNLESS OTHERWISE NOTED. 5.PROVIDE CORNER BARS OF EQUAL SIZE AND SPACING AROUND ALL CORNERS. 6.ALL REINFORCING SPACINGS ARE MAXIMUM ON CENTER AND ALL REINFORCING IS CONTINUOUS UNLESS OTHERWISE NOTED. 7.CONCRETE TO INCLUDE FIBERMESH 300 (3 4" FIBERS) AT 1.5 LBS PER CUBIC YARD. 8.MAINTAIN 2" MIN. & 2.5" MAX. CLEARANCE BETWEEN BOTTOM OF SLAB TO BOTTOM OF SNOWMELT TUBING TO ENSURE PROPER SAW CUT DEPTH CAN BE ACCOMMODATED WITHOUT DAMAGING SNOWMELT SYSTEM. SCALE: N.T.S. 4' DRAIN CONCRETE PAN SCALE: N.T.S. STORM DRAIN INLET DETAIL NOTES: 1.CITY OF ASPEN INLET STRUCTURE DETAIL PROVIDED FOR MINIMUM REQUIREMENTS. CONTRACTOR SHALL SUPPLY SHOP DRAWINGS FOR FINAL APPROVAL. 2.SINGLE GUTTER INLETS LOCATED ADJACENT TO VERTICAL CURB SHALL BE NEENAH 3462-B 8" MIN. UNLESS OTHERWISE NOTED SCALE: N.T.S. TYPICAL CONCRETE WITH SNOWMELT & IN TRAFFIC RATED AREAS TYPICAL CONCRETE PAVEMENT SUBGRADE SECTION (SEE DETAIL 3/C6.0) SAW CUT; RE. TO NOTE 5 2" MIN.CLR. 2" (R-10) HIGH DENSITY RIGID INSULATION UNDER CONCRETE 30 PSI MIN. (NON-TRAFFIC AREAS) 100 PSI MIN. (TRAFFIC RATED AREAS) WIRE TIE 5 8" DIA. SNOWMELT TUBING TO STL. REINFORCEMENT AS NECESSARY TO PREVENT TUBING FROM FLOATING. NOTES: 1.CONCRETE MUST CONFORM TO CDOT CLASS D (MIN. 28-DAY COMPRESSIVE STRENGTH OF 4,500 PSI); 80% OF THIS STRENGTH TO BE ACHIEVED IN THE FIRST 7-DAYS. 2.RE. TO ARCHITECTURAL PLANS FOR SNOWMELT AREAS 3.RE. TO MECH. DWGS FOR SNOWMELT SYSTEM DESIGN 4.SNOWMELT CONCRETE TO INCLUDE STEEL REINFORCEMENT; RE. TO CONCRETE REINFORCEMENT NOTES 5.SAW CUTS IN TRAFFIC RATED AREAS SHALL BE T/3 IN DEPTH & 3 16" WIDE; SAW CUTS IN NON-TRAFFIC RATED AREAS SHALL BE SET AT T/4 IN DEPTH & 3 8" WIDE. 6.CONTROL JOINT SPACING SHALL NOT EXCEED A 1.5:1 RATIO (LENGTH:WIDTH) 7.RE. LANDSCAPE PLANS FOR FINISH AND CONTROL JOINT PATTERN. 8.RE. LANDSCAPE PLANS FOR DECORATIVE SAWCUT LAYOUT. 9.SAWCUT CONTROL JOINTS TO INCLUDE BACKER ROD AND JOINT SEALANT. REINFORCING NOTES: 1.REINFORCING BARS SHALL BE ASTM A-615 GRADE 60. 2.REINFORCEMENT BARS SHALL BE #4 AND SPACED 18-INCH ON CENTER BOTH WAYS (X & Y). 3.MAINTAIN A 2" MINIMUM CLEAR DISTANCE FROM EDGE OF BAR TO EDGE OF CONCRETE. 4.REINFORCING LAP SPLICES SHALL BE A MINIMUM OF 40 BAR DIAMETERS UNLESS OTHERWISE NOTED. 5.PROVIDE CORNER BARS OF EQUAL SIZE AND SPACING AROUND ALL CORNERS. 6.ALL REINFORCING SPACINGS ARE MAXIMUM ON CENTER AND ALL REINFORCING IS CONTINUOUS UNLESS OTHERWISE NOTED. 7.CONCRETE TO INCLUDE FIBERMESH 300 (3 4" FIBERS) AT 1.5 LBS PER CUBIC YARD. 8.MAINTAIN 2" MIN. & 2.5" MAX. CLEARANCE BETWEEN BOTTOM OF SLAB TO BOTTOM OF SNOWMELT TUBING TO ENSURE PROPER SAW CUT DEPTH CAN BE ACCOMMODATED WITHOUT DAMAGING SNOWMELT SYSTEM. 6" MIN. CLASS 6 ABC CONC. SECTION VARIES (SEE NOTE 1 BELOW) COMPACTED TO 95% OF MAX MODIFIED PROCTOR DENSITY WITHIN 2% OF OPTIMUM MOISTURE PREPPED SUBGRADE OR STRUCTURE BELOW STRUCTURAL BACKFILL (VARIES) NOTES: 1.CONCRETE IN NON-TRAFFIC RATED SIDEWALK AREAS SHALL BE A MIN. OF 4-INCHES & SNOWMELT CONCRETE & CONCRETE IN TRAFFIC RATED AREAS SHALL BE A MIN. OF 8-INCHES. 2.CONCRETE MUST CONFORM TO CDOT CLASS D (MIN. 28-DAY COMPRESSIVE STRENGTH OF 4,500 PSI); 80% OF THIS STRENGTH TO BE ACHIEVED IN THE FIRST 7-DAYS. 3.CONCRETE THICKNESS SHALL BE A 8" MIN. IN SNOWMELT & TRAFFIC AREAS. NON-SNOWMELT & NON-TRAFFIC RATED AREAS SHALL BE 4" MIN. 4.CONCRETE SHALL CONTAIN FIBERMESH 300 PER OR APPROVED EQUIVALENT PER MANUFACTURER'S RECOMMENDATIONS. 5.CONTRACTOR TO EXCAVATE EXISTING SUBGRADE AS REQUIRED TO ACCOMMODATE THE CONCRETE PAVEMENT SECTION. 6.AGGREGATE BASE COURSE SHALL BE LAID IN THIN LIFTS NOT TO EXCEED 6-INCHES, MOISTURE TREATED TO WITHIN 2 PERCENT OF OF OPTIMUM MOISTURE CONTENT, AND COMPACTED TO AT LEAST 95% OF MAXIMUM MODIFIED PROCTOR DENSITY. 7.PLACEMENT AND COMPACTION OF AGGREGATE BASE COURSE SHALL BE OBSERVED AND TESTED BY THE PROJECT GEOTECHNICAL ENGINEER. PLACEMENT SHALL NOT COMMENCE UNTIL THE UNDERLYING SUBGRADE IS PROPERLY PREPARED AND TESTED. 8.THE SUBGRADE & BASE COURSE SHALL BE PROOF ROLLED AFTER THE REQUIRED COMPACTION HAS BEEN OBTAINED AND THE SUBGRADE HAS BEEN SHAPED TO THE REQUIRED CROSS SECTION. PROOF ROLLING SHALL BE PERFORMED IN ACCORDANCE WITH CDOT SPECIFICATIONS WITH A VEHICLE WITH A MINIMUM AXLE LOAD OF 18 kips PER AXLE AND OBSERVED BY PROJECT ENGINEER AND/OR PROJECT GEOTECHNICAL ENGINEER. 9.ALL CONTROL JOINT SPACING SHALL NOT EXCEED 1.5:1 RATIO (LENGTH:WIDTH) SCALE: N.T.S. TYPICAL CONCRETE PAVEMENT SUBGRADE SECTION 14" MIN. 15" MIN. 8" CONC.; RE. TO DETAIL SILVA CELL 2 SYSTEM (DECK, BASE & POSTS) 6" MAX. SCALE: N.T.S. CONCRETE TURNDOWN AT SILVA CELL EDGE 4" MIN. 3 4" MINUS CDOT #67 OR APPROVED EQUAL GEOTEXTILE FABRIC 12" 12" SCALE: N.T.S. TYPICAL TRENCH DETAIL FOR PVC OR HDPE DRAIN LINES BEDDING OF CLASS 6 AGGREGATE BASE COURSE OR SUITABLE ONSITE MATERIAL APPROVED BY PROJECT GEOTECHNICAL ENGINEER SELECT MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY6" MIN. 4" MIN. x x x x x x x x x x x x x x x 10-10-20191 SD PRICING SCALE: N.T.S. TYPICAL DRY WELL DETAIL PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 3-2-20203 DETAILED REVIEW DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 2 : 4 3 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 5 . 0 0 - C . 5 . 0 2 S I T E D E T A I L S . d w g CJB JKS C.5.01 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 SANITARY SWER DETAILS CLASS 6 AGGREGATE BASE COURSE CLASS 6 ABC RE. TO COA OF ASPEN SHEER STEP ASPHALT PATCH DETAIL THIS SHEET. CLASS 6 AGGREGATE BASE COURSE CLASS 6 ABC ACCEPTABLE TO ACSD N.T.S. SEWER LINE CONNECTION AT SEWER MAIN REMOVABLE STOPPER IF SERVICE TO BUILDING IS NOT IN PLACE SEWER MAIN 45° BEND INSTALL SADDLE TAP ON EXISTING SEWER MAIN & EXTEND SEWER SERVICE MIN. GRADE 2% (1/4" PER FOOT) SDR-26 SEWER SERVICE LINE CLEANOUT DETAIL TYLER UNION 51 4" SLIP TYPE SHAFT OR APPROVED EQUIVALENT LANDSCAPING SEWER 24 " M I N . CAST IRON OR BRASS VALVE BOX COVER LABELED "SEWER" CLOSED PICKHOLES (2) NYLON CLEANOUT PLUG (PETERSON PRODUCTS OR PRE-APPROVED EQUIVALENT) SET 4" BELOW GRADE CAST IRON OR BRASS VALVE BOX COVER; RE. TO DETAIL SCH. 40 PVC CLEANOUT RISER PLACE BOND BREAKER (PLASTIC) AROUND VALVE IN CONCRETE AREAS SCH. 40 PVC 2-WAY CLEANOUT TEE SCH. 40 PVC TO BUILDING SDR 26 TO SEWER MAIN FLOW N.T.S. 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 3-2-20203 DETAILED REVIEW DATE#DESCRIPTION ISSUE DATE: SHEET NUMBER REVIEWED:DRAWN: REVISIONS GO R S U C H H A U S NO R W A Y I S L A N D , L L C . AS P E N , C O L O R A D O W W W . S O P R I S E N G . C O M F e b 2 4 , 2 0 2 0 - 2 : 4 3 p m G: \ 2 0 1 5 \ 1 5 1 0 1 . 0 6 - G o r s u c h H a u s \ C I V I L \ C i v i l D W G s \ P L O T \ C . 5 . 0 0 - C . 5 . 0 2 S I T E D E T A I L S . d w g CJB JKS C.5.02 OPRIS ES NGINEERING, LLC. CIVIL CONSULTANTS 502 MAIN STREET CARBONDALE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 CITY OF ASPEN WATER DETAILS 10-10-20191 SD PRICING PROJECT NUMBER:15101.06 1-15-20202 DETAILED REVIEW-DRAFT PROJECT DETAILED REVIEW NOTE: THESE PLANS ARE CONCEPTUAL OR ILLUSTRATIVE IN NATURE. PRECISE INFORMATION SHALL BE PROVIDED AS PART OF THE BUILDING PERMIT APPLICATION, AND IN SITUATIONS WHERE THE FINAL PD DEVELOPMENT PLANS AND APPROVED BUILDING PERMIT DIFFER, THE APPROVED BUILDING PERMIT SHALL RULE. 3-2-20203 DETAILED REVIEW NE1/4 13 FOUND 1" IRON PIPE CITY BLOCK MONUMENT GPS-6 FOUND 3.5" ALUMINUM CAP MARCIN GPS CONTROL AT THE APPROXIMATE INTERSECTION OF HOPKINS AVE. AND GARMISCH ST. FOUND #6 REBAR AND 3.5" ALUMINUM CAP FOR THE 1/4 CORNER SECTION 12 AND 13 2008 L.S. #16129 FOUND #6 REBAR AND 3.25" ALUMINUM CAP FOR THE N-E 1/16TH CORNER SECTION 13 N89° 55' 06"E 2665.35' 13 2 2 . 9 3 ' 13 2 2 . 9 3 ' 1332.68'1332.68' CORNER SECTION 12/13 T10S R85W AND 7/18 T10S R84W CORNER DESTROYED WITH CONSTRUCTION IN 2008 - SEE WITNESSES SET PER MONUMENT RECORD 132.5' WITNESS CORNER TO THE NE CORNER SECTION 13 FOUND #6 REBAR AND 3.25" ALUMINUM REFERENCE CAP L.S. #28643 115.0' WITNESS CORNER TO THE NE CORNER SECTION 13 FOUND #6 REBAR AND 3.25" ALUMINUM REFERENCE CAP L.S. #28643 BLOCK 3 EAMES ADDITI O N JUAN S T R E E T DEAN S T R E E T ASPEN TOWNSITE CORNER 9 FOUND "X" ON ROCK FOR CORNER 18 MS 5884 LI T T L E M A C K M S 3 9 5 6 MO L L I E G M S 7 5 7 7 FOUND CORNER 4 MS 3956 FOUND CORNER 4 MS 7577 LITT L E C H I E F M S 5 8 5 0 CO N N E R P L A C E R M S 2 5 3 5 JOTE S M I T H M S 3 9 1 4 A M PI O N E E R M S 1 7 2 1 SOUTH LINE GOVERNMENT LOT 1 (NE1/4NE1/4) NORTH LINE GOVERNMENT LOT 31(SE1/4NE1/4 POST AT INTERSECTION OF MS5884 AND MS3956 MS 5 8 8 4 TOP OF MILL SUBDIVISION MTN QUEEN SUBDIVISION SOUTH ASPEN STREET PUD BARBEE FAMILY SUBDIVISION S. A S P E N S T R E E T CORNER 2 MS5850 FOUND 3.25" BLM BRASS CAP INTERSECTION MS5850 AND MS2535 FOUND 3.25" BRASS CAP BLM 1985 INTERSECTION MS2535 AND EAST LINE SECTION 13 FOUND 3.25" BRASS CAP SET IN CONCRETE RETAINING WALL BLM 1985 CORNER 3 MS2535 FOUND 3.25" BRASS CAP SET IN CONCRETE RETAINING WALL BLM 1985 SOUT H A N N E X A T I O N T O T H E C I T Y O F A S P E N PITKIN C O U N T Y MO N A R C H S T R E E T HILL ST R E E T SUMM I T S T R E E T FOUND INTERSECTION ASPEN TOWNSITE LINE AND NORTH LINE SECTION 13 FOUND 1/4 CORNER SECTION 13/24 IRON PIPE WITH 3" BRASS CAP BLM 1978 FOUND 1/4 CORNER SECTION 13/14 2.5" IRON PIPE WITH 3.25" BRASS CAP BLM 1954 FOUND 1/4 CORNER SECTION 13 T10S R85W/18 T10S R84W 3.25" BRASS CAP ON METAL POST BLM 1954 FOUND 3" ALUMINUM CAP ILLEGIBLE BEARS N 77°29'44" E 9.29' FROM CORNER 3 MS5850 NO MONUMENT RECORD ON FILE CANNOT DETERMINE ORIGIN FOUND #5 REBAR AND 11 4" PLASTIC CAP L.S. #25947 (B A S I S O F BE A R I N G ) N1 4 ° 5 0 ' 4 9 " E GPS-3 FOUND 3.5" ALUMINUM CAP MARCIN GPS CONTROL AT THE APPROXIMATE INTERSECTION OF DURANT AVE. AND GARMISCH ST. N1 4 ° 5 0 ' 4 9 " E 3 1 7 . 9 4 ' 13 0 8 . 7 9 ' N1/16 SECTION 13 T10S R85W AND SECTION 18 T10S R84W NO CORNER FOUND TO BE SET 1336.34' GOVERNMENT LOT 31 (WITHIN CITY OF ASPEN) GOVERNMENT LOT 1 SH A D O W M T N CO N D O M I N I U M S SOUTH ASPEN STREET PUD LIFT ONE LODGE PUD GOVERNMENT LOT 38 2648.33' GOVERNMENT LOT 31 (WITHIN PITKIN COUNTY) 13 0 8 . 7 9 ' 1336.34' FOUND #5 REBAR AND 11 4" PLASTIC CAP L.S. #28643 N23° 37' 06"W 933.16' S13° 35' 04"E 830.86' 3017893.38GARMISCH & HOPKINS3017893.38GARMISCH & HOPKINS FOUND #5 REBAR AND 11 4" PLASTIC CAP L.S. #28643 DR A F T FINAL PLAT OF: SHEET 1 OF 4 DEDICATION, CERTIFICATES, AND CONTROL DIAGRAM GORSUCH HAUS PD/SUBDIVISION A PARCEL OF LAND SITUATED IN THE NE1 4 OF SECTION 13, TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE 6th P.M., CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO THE PURPOSE OF THIS PLAT IS TO CREATE A PLANNED DEVELOPMENT (PD), REZONE, AND SUBDIVIDE THE SUBJECT PROPERTY PLAT NOTES 1. LOT 2 IS RESTRICTED AGAINST ALL FUTURE RESIDENTIAL BUILDING AND RESIDENTIAL DEVELOPMENT AND OTHER LAND USES AND ACTIVITIES THAT ARE NOT CONSISTENT WITH THE INTENT AND APPROVED DEVELOPMENT OUTLINED IN ORDINANCE 39 (SERIES OF 2016) (HEREINAFTER “ORDINANCE 39”). 2. ORDINANCE 39 EXPRESSLY AUTHORIZES THE CONSTRUCTION AND USE OF ALL SKI AND NON-MECHANIZED RECREATIONAL INFRASTRUCTURE, INCLUDING SKI LIFTS, TOWERS, SNOWMAKING EQUIPMENT, ACCESSORY AND SUPPORT STRUCTURES APPROVED FOR PLACEMENT ON LOT 2 AND ON CERTAIN PORTIONS OF LOT 1 AS WELL AS THE ABILITY TO CONDUCT SKIING, RECREATIONAL USES THAT DO NOT REQUIRE MECHANIZED INFRASTRUCTURE, ALL RELATED SKI AND RECREATIONAL OPERATIONS AND ACCESSORY SKI AND RECREATIONAL USES, INCLUDING SNOWMAKING, SNOW MANAGEMENT, GROOMING, HIKING, BIKING, UPHILLING AND EVENTS RELATED THERETO, AS WELL AS TRADITIONAL AND ROUTINE SKI OPERATIONS AND MAINTENANCE ON THE PROPERTY, INCLUDING MOUNTAIN ACCESS ROAD USE AND MAINTENANCE, AS WELL AS MOTORIZED VEHICLE, EQUIPMENT AND MATERIAL STAGING AND ACCESS IN BOTH WINTER AND SUMMER SEASONS ALONG THE MOUNTAIN ACCESS ROAD. 3. ORDINANCE 39 ALSO EXPRESSLY ALLOWS FOR ALL ANCILLARY AND APPROVED SPECIAL EVENTS TO BE CONDUCTED ON LOT 2. NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. SOPRIS ENGINEERING - LLC CIVIL CONSULTANTS 502 MAIN STREET, SUITE A3 CARBONDALE, COLORADO 81623 (970) 704-0311 CL sb 13139.01 02/26/2020 G:\2013\13139\SURVEY\Survey DWGs\Survey Plots\13139-SUBDIVISION.dwg CLERK AND RECORDER'S ACCEPTANCE THIS FINAL PLAT OF GORSUCH HAUS PD/SUBDIVISION IS ACCEPTED FOR FILING IN THE OFFICE OF THE CLERK AND RECORDER OF PITKIN COUNTY, COLORADO THIS ______ DAY OF _______________, 2020 IN PLAT BOOK _____ AT PAGE _____ , AS RECEPTION NO. ________________. _______________________________________ PITKIN COUNTY CLERK AND RECORDER CERTIFICATE OF OWNERSHIP, DEDICATIONS AND RESERVATIONS KNOW ALL MEN BY THESE PRESENTS, THAT ASPEN SKIING COMPANY (“ASC”) BEING THE RECORD TITLE OWNER OF THE SUBJECT PROPERTY AS DESCRIBED AND DEPICTED ON SHEET 2 HEREOF, SITUATED IN THE CITY OF ASPEN, PITKIN COUNTY, COLORADO. PURSUANT TO AND IN ACCORDANCE WITH ORDINANCE NO. 39, SERIES OF 2016, (HEREINAFTER, “ORDINANCE 39”) RECORDED APRIL 8, 2019 IN THE PITKIN COUNTY REAL PROPERTY RECORDS UNDER RECEPTION NO. 655085, OWNER HAS, BY THESE PRESENTS, LAID OUT, PLATTED AND SUBDIVIDED THE SAME INTO LOTS 1 AND 2, AS DEPICTED AND DESCRIBED HEREON UNDER THE NAME AND STYLE OF GORSUCH HAUS PD/SUBDIVISION. ASC EXPRESSLY RESERVES THE RIGHT TO ENGAGE IN SKI OPERATIONS ON, OVER AND ACROSS ALL OF LOT 2 IN CONJUNCTION WITH THE OPERATION AND MANAGEMENT OF THE ASPEN MOUNTAIN SKI AREA. IN THIS REGARD, ASC EXPRESSLY RESERVES THE RIGHT TO CONDUCT AND ACCOMMODATE SKIING, SKI OPERATIONS AND RECREATIONAL ACTIVITIES ON THE PROPERTIES COVERED BY THIS PLAT AS DESCRIBED IN THE PLAT NOTES ON SHEET 4 HEREOF, INCLUDING, WITHOUT LIMITATION TO CONDUCT AND ACCOMMODATE SKI ACTIVITIES AND SKI OPERATIONS ON THE “SKIWAY” SHOWN AND IDENTIFIED ON SHEET 4 HEREOF. ALL OF THE FOLLOWING DEDICATIONS AND RESERVATIONS ARE MADE SUBJECT TO SUCH RESERVED RIGHTS AND EXPRESS AUTHORIZATIONS CONTAINED IN ORDINANCE 39 TO ENGAGE IN SKI ACTIVITIES AND RECREATIONAL OPERATIONS ON LOT 2, AND SPECIFICALLY WITHIN THE SKIWAY ON LOT 1 AND LOT 2. ASC HEREBY MAKES THE FOLLOWING DEDICATIONS AND RESERVATIONS FOR THIS PLAT: 1.DOES HEREBY DEDICATE TO THE CITY OF ASPEN THOSE PORTIONS OF THE LANDS CONTAINED HEREIN SHOWN AND DEPICTED ON SHEET 3 HEREON, AND LABELED “DEDICATED ROW” FOR PURPOSES OF CONSTRUCTING, OPERATING, AND MAINTAINING SUBGRADE PUBLIC UTILITIES, A PUBLIC ROADWAY, PEDESTRIAN SIDEWALK, AND OTHER ASSOCIATED IMPROVEMENTS NECESSARY FOR VEHICULAR AND PEDESTRIAN TRAVEL; AND 2.DOES HEREBY DEDICATE AND GRANT A PERPETUAL, NON-EXCLUSIVE PUBLIC TRAIL EASEMENT, FIVE (5) FEET IN WIDTH, FOR PURPOSES OF NON-MOTORIZED INGRESS AND EGRESS, COMMENCING ON THE NORTHERLY BOUNDARY LINE OF THE PUBLIC PEDESTRIAN EASEMENT ON LOT 1 AS SHOWN HEREON AND THENCE CONTINUING IN A NORTHEASTERLY DIRECTION OVER LOT 1 AND THE HILL STREET RIGHT OF WAY AND THENCE CONTINUING IN A SOUTHEASTERLY DIRECTION ACROSS LOT 2, IN THE AREA DEPICTED AS THE "PUBLIC TRAIL EASEMENT" ALIGNMENT SHOWN AND DEPICTED ON SHEET 4 HEREOF; SUCH PUBLIC TRAIL EASEMENT EXTENDS TO A POINT ON THE EASTERLY BOUNDARY LINE OF LOT 2, WHICH POINT COINCIDES WITH THE WESTERLY BOUNDARY LINE OF THE ADJOINING SKIER AND PEDESTRIAN EASEMENT SHOWN AND DESCRIBED IN THE DOCUMENT RECORDED IN PLAT BOOK 4 AT PAGE 489; OWNER RESERVES THE RIGHT TO UNILATERALLY RE-ALIGN THIS PUBLIC TRAIL EASEMENT TO COINCIDE WITH THE AS-BUILT LOCATION THEREOF AND ASC ALSO RESERVES THE RIGHT TO UTILIZE LOT 2 FOR SKI AREA OPERATIONS AND TO PROHIBIT PEDESTRIAN, BICYCLE OR SIMILAR USES OF THE PUBLIC TRAIL EASEMENT DURING THE SKI SEASON AND TO LIMIT THE USE OF AND/OR TEMPORARILY CLOSE THE PUBLIC TRAIL EASEMENT DURING THE SKI SEASON TO ACCOMMODATE SNOWMAKING, SNOW STORAGE, SNOW GROOMING, SKIING AND OTHER WINTER SKI OPERATIONS; AND 3.DOES HEREBY DEDICATE AND RESERVE A RECIPROCAL, NON-EXCLUSIVE CONSTRUCTION EASEMENT FOR THE USE AND BENEFIT OF THE OWNERS OF LOTS 1 AND 2 AND THEIR RESPECTIVE GRANTEES, SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS, AND EMPLOYEES OVER, UPON, AND ACROSS ONLY THE PORTIONS OF LOTS 1 AND 2 NECESSARY TO COMPLETE THE IMPROVEMENTS ON SAID LOTS WITHIN THE AREA DEPICTED AS THE “TEMPORARY CONSTRUCTION EASEMENT” SHOWN AND DEPICTED ON SHEET 4 HEREOF, INCLUDING THE EXCAVATION, SHORING, DEWATERING AND ALL OTHER CONSTRUCTION ACTIVITIES APPROVED IN ACCORDANCE WITH CITY OF ASPEN ORDINANCE 39 (SERIES OF 2016), TOGETHER WITH A REASONABLE RIGHT OF ACCESS FOR THE ACCOMPLISHMENT OF SUCH PURPOSES. THIS RECIPROCAL TEMPORARY CONSTRUCTION EASEMENT SHALL BE TEMPORARY AND SHALL AUTOMATICALLY TERMINATE UPON THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR THE IMPROVEMENTS APPROVED AND CONSTRUCTED UNDER ORDINANCE 39; THE TERMS AND CONDITIONS OF THIS RECIPROCAL TEMPORARY CONSTRUCTION EASEMENT ARE MORE PARTICULARLY DESCRIBED IN THAT CERTAIN RECIPROCAL TEMPORARY CONSTRUCTION EASEMENT RECORDED IN THE OFFICE OF THE PITKIN COUNTY CLERK & RECORDED AT RECEPTION NO. _________________________; AND 4. DOES HEREBY DEDICATE AND RESERVE RECIPROCAL, PERPETUAL, NON-EXCLUSIVE SUBSURFACE STRUCTURAL EASEMENTS OF VARYING WIDTHS ALONG EITHER SIDE OF PORTIONS OF THE COMMON BOUNDARY OF LOTS 1 AND 2 (THE “SUBSURFACE STRUCTURAL EASEMENTS”), SHOWN AND DEPICTED ON SHEET 4 HEREOF, FOR THE USE AND BENEFIT OF THE OWNERS OF SAID LOTS AND THEIR RESPECTIVE GRANTEES, SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS, AND EMPLOYEES FOR THE PURPOSE OF CONSTRUCTING AND MAINTAINING ANY SUBSURFACE FOUNDATIONS, FOOTER PADS, DEWATERING FACILITIES, DRAINAGE FACILITIES OR OTHER STRUCTURAL ELEMENTS OF THOSE STRUCTURES THAT MAY BE CONSTRUCTED WITHIN SAID SUBSURFACE STRUCTURAL EASEMENTS, TOGETHER WITH A REASONABLE RIGHT OF ACCESS FOR THE ACCOMPLISHMENT OF SUCH PURPOSES PROVIDED THAT THE SAME DOES NOT INTERFERE WITH ASC’S LIFT FACILITIES, UTILITIES AND OPERATIONS; AND, ASC RESERVES THE RIGHT TO UNILATERALLY RE-ALIGN SUBSURFACE STRUCTURAL EASEMENTS TO COINCIDE WITH THE AS-BUILT LOCATIONS OF SUCH STRUCTURAL ELEMENTS; AND 5.DOES HEREBY DEDICATE AND RESERVE A NON-EXCLUSIVE PRIVATE ACCESS EASEMENT OVER, UPON, AND ALONG THE MOUNTAIN OPERATIONS ROAD, SHOWN AND DEPICTED ON SHEET 4 HEREOF AS IT CROSSES LOT 2, LABELED "MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT," AND OVER, UPON AND ALONG THOSE PORTIONS OF LOT 2 LOCATED WEST OF THE MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT, FOR THE USE AND BENEFIT OF THE OWNER OF LOT 1 AND ITS SUCCESSORS, ASSIGNS, EMPLOYEES, LICENSEES AND INVITEES FOR THE PURPOSES OF VEHICULAR AND PEDESTRIAN ACCESS FROM TIME TO TIME NECESSARY FOR THE OPERATION, MAINTENANCE AND UPKEEP OF IMPROVEMENTS LOCATED ON SAID LOT 1 AND FOR ACCESS TO LIMITED, PERIODIC SPECIAL EVENTS ACTIVITIES LOCATED ON, IN AND AROUND PUBLIC AMENITIES SPACES ON LOT 1; SUCH PRIVATE ACCESS EASEMENT DOES NOT CONFER ANY RIGHTS TO THE GENERAL PUBLIC, AND NO PUBLIC ACCESS IS INTENDED TO BE CREATED BY THIS DEDICATION; ASC FOR ITSELF, ITS GRANTEES, SUCCESSORS AND ASSIGNS, RESERVES THE RIGHT TO LIMIT THE USE OF AND/OR TEMPORARILY DENY THE OWNER OF LOT 1 AND ITS SUCCESSORS, ASSIGNS, EMPLOYEES, LICENSEES, AND INVITEES ACCESS TO THE MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT DURING THE SKI SEASON TO ACCOMMODATE SNOWMAKING, SNOW STORAGE, SNOW GROOMING, SKIING AND OTHER WINTER SKI OPERATIONS; AND 6.DOES HEREBY DEDICATE AND GRANT A PERPETUAL, NON-EXCLUSIVE PUBLIC PEDESTRIAN EASEMENT OVER AND ACROSS LOT 1 AND SUCH PORTIONS OF LOT 2 AS ARE SPECIFICALLY IDENTIFIED ON PAGE 4 HEREOF FOR PURPOSES OF NON-MOTORIZED, PEDESTRIAN-ONLY ACCESS OVER AND UPON A STRIP OF LAND AS SHOWN AND DEPICTED ON SHEET 4 HEREOF AND LABELED “PUBLIC PEDESTRIAN EASEMENT” [NOTE: THIS EASEMENT IS FOR (A) PUBLIC PEDESTRIAN ACCESS WITHIN THE 8’ WIDE SIDEWALK ON THE OUTER EDGE OF THE CUL-DE-SAC, (B) THE STAIRWAY AREAS ALONG THE WEST SIDE OF LOT 1 AND (C) THE IRREGULARLY SHAPED AREA PROVIDING PEDESTRIAN ACCESS OVER AND ACROSS THE FAR WESTERN PORTION OF LOT 2 TO THE BARBEE OPEN SPACE PARCEL.]; ASC RESERVES THE RIGHT FOR ITSELF, ITS GRANTEES, SUCCESSORS AND ASSIGNS TO BLOCK, LIMIT OR DENY ACCESS TO SUCH PORTIONS OF THE PUBLIC PEDESTRIAN EASEMENT AS ARE NECESSARY FOR PURPOSES OF USE OF THE MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT BY THE OWNER OF LOT 1 FOR PURPOSES AS DESCRIBED IN PARAGRAPH 5 ABOVE AND ASC, ITS GRANTEES, SUCCESSORS, ASSIGNS, LICENSEES AND INVITEES, AS DESCRIBED IN PARAGRAPH 10 BELOW; AND 7.DOES HEREBY DEDICATE AND RESERVE FOR THE USE AND BENEFIT FROM TIME TO TIME OF THE OWNERS OF LOTS 1 AND 2 AND THEIR RESPECTIVE GRANTEES, SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS, AND EMPLOYEES, PERPETUAL, NON-EXCLUSIVE EASEMENTS ON THOSE PORTIONS OF LOTS 1 AND 2 ALONG THE ENTIRE COURSE OF THE ON-SITE DRAINAGE IMPROVEMENTS SHOWN AND DEPICTED ON THE CONCEPTUAL MASTER DRAINAGE PLAN (SHEET C.4.02) RECORDED SIMULTANEOUSLY WITH THIS PLAT, FOR PURPOSES OF CONSTRUCTION, INSTALLATION, USE, OPERATION, MAINTENANCE, REPAIR, REMOVAL AND REPLACEMENT OF PRIVATE ON-SITE STORM WATER DRAINAGE SYSTEMS FACILITIES, WITH ALL APPROPRIATE SUB-SURFACE AND SURFACE IMPROVEMENTS, TOGETHER WITH A REASONABLE RIGHT OF ACCESS FOR THE ACCOMPLISHMENT OF SUCH PURPOSES (COLLECTIVELY, THE "DRAINAGE EASEMENTS"); ASC RESERVES THE RIGHT TO UNILATERALLY RELOCATE THE ACTUAL LOCATION OF SUCH DRAINAGE EASEMENTS TO COINCIDE WITH THE AS-BUILT LOCATION OF SUCH DRAINAGE IMPROVEMENTS; AND 8.DOES HEREBY DEDICATE AND RESERVE THE RIGHT TO GRANT EASEMENTS AND LICENSES TO AND FOR THE USE AND BENEFIT OF UTILITY COMPANIES OWNING, OPERATING OR OTHERWISE MANAGING THE UTILITY LINES AND SYSTEMS WITHIN LOTS 1 AND 2, AND FOR THE USE AND BENEFIT FROM TIME TO TIME OF THE OWNERS OF SAID LOTS AND THEIR RESPECTIVE GRANTEES, SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS, AND EMPLOYEES, A PERPETUAL, NON-EXCLUSIVE UTILITY EASEMENT OVER, UPON, AND BENEATH THE "UTILITY EASEMENT" SHOWN AND LABELED ON SHEET 4 HEREOF, FOR THE PURPOSE OF CONSTRUCTION, INSTALLATION, ENLARGEMENT, USE, OPERATION, MAINTENANCE, REPAIR, REMOVAL AND REPLACEMENT OF UNDERGROUND UTILITIES INCLUDING WATER, SEWER, STORM WATER DRAINAGE, GAS, ELECTRICITY, TELEPHONE, TELEVISION AND TELECOMMUNICATIONS, TOGETHER WITH ASSOCIATED EQUIPMENT AND FACILITIES REQUIRED ABOVE GROUND, REGARDING WHICH ALL SAID EASEMENTS AND LICENSES SHALL BE IN LOCATIONS REASONABLY APPROVED IN ADVANCE BY THE OWNER(S) OF THE IMPACTED LOT(S), TOGETHER WITH A REASONABLE RIGHT OF ACCESS FOR THE ACCOMPLISHMENT OF SUCH PURPOSES; THE FINAL OWNER UTILITY EASEMENTS TO COINCIDE WITH THE AS-BUILT LOCATIONS OF SUCH UTILITIES; AND 9.DOES HEREBY RESERVE UNTO ASC, ITS GRANTEES, SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS, AND EMPLOYEES, AS THE OWNER, OPERATOR OR MANAGER OF THE LIFT FACILITIES LOCATED ON LOT 1 A PERPETUAL, NON-EXCLUSIVE EASEMENT OVER, UPON AND BENEATH THE "LIFT FACILITIES EASEMENT" SHOWN ON SHEET 4 HEREOF, FOR THE PURPOSE OF CONSTRUCTING, INSTALLING, ENLARGING, OPERATING (INCLUDING, WITHOUT LIMITATION, TRANSPORTING PEOPLE, GOODS AND MATERIALS), MAINTAINING, REPAIRING, REMOVING AND REPLACING LIFT FACILITIES, AND FOR THE ADDITIONAL USE AND BENEFIT OF ASC, ITS GRANTEES, SUCCESSORS, ASSIGNS, LICENSEES AND INVITEES; AND 10.DOES HEREBY RESERVE FOR THE USE AND BENEFIT OF ASC, ITS GRANTEES, SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS AND EMPLOYEES, AS OPERATOR AND MANAGER OF THE LIFT FACILITIES WITHIN THE LIFT FACILITIES EASEMENT DESCRIBED ABOVE AND AS OPERATOR AND MANAGER OF THE ASPEN MOUNTAIN SKI AREA, A NON-EXCLUSIVE PRIVATE ACCESS EASEMENT OVER, UPON, AND ALONG THE MOUNTAIN OPERATIONS ROAD, SHOWN AND DEPICTED ON SHEET 4 HEREOF AS IT CROSSES LOT 1, LABELED "MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT," FOR THE USE AND BENEFIT OF THE OWNER OF LOT 2 AND ITS SUCCESSORS, ASSIGNS, EMPLOYEES, LICENSEES AND INVITEES FOR THE PURPOSE OF VEHICULAR AND PEDESTRIAN ACCESS FROM TIME TO TIME NECESSARY FOR THE OPERATION AND MAINTENANCE OF IMPROVEMENTS LOCATED ON LOT 2 AND FOR ACCESS TO THE ASPEN MOUNTAIN SKI AREA THROUGHOUT THE YEAR; SUCH PRIVATE ACCESS EASEMENT INCLUDES THE RIGHT TO INSTALL SNOWMAKING WATER LINES AND ENGAGE IN SNOWMAKING, SNOW STORAGE, SNOW GROOMING, SKIING AND SKI OPERATIONS, INCLUDING, WITHOUT LIMITATION, SKI RACING AND SPECIAL EVENTS, ON THAT PORTION OF THE SKIWAY LOCATED WITHIN THE MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT; SUCH PRIVATE ACCESS EASEMENT DOES NOT CONFER ANY RIGHTS TO THE GENERAL PUBLIC, AND NO PUBLIC ACCESS OR USE OF THE MOUNTAIN OPERATIONS ROAD AS SHOWN HEREON IS INTENDED TO BE CREATED BY THIS PLAT, EXCEPT AS OUTLINED IN DEDICATION PARAGRAPH 12 HEREON; AND 11.DOES HEREBY DEDICATE AND RESERVE FOR THE USE AND BENEFIT FROM TIME TO TIME OF THE OWNERS OF LOTS 1 AND 2 AND THEIR RESPECTIVE GRANTEES, SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS, AND EMPLOYEES, A PERPETUAL, NON-EXCLUSIVE “UTILITY SERVICE LINE EASEMENT” OVER, UNDER AND UPON SAID LOTS ALONG THE ENTIRE COURSE OF ALL UTILITY SERVICE LINES THAT MAY BE CONSTRUCTED BETWEEN OR OTHERWISE CONNECT TO THE UTILITY SERVICE LINES AND MAINS ON LOTS 1 AND 2 TO THE IMPROVEMENTS THEREON, IN THE AS-BUILT LOCATIONS OF SUCH UTILITY SERVICE LINES, FOR PURPOSES OF CONSTRUCTION, INSTALLATION, USE, OPERATION, MAINTENANCE, REPAIR, REMOVAL AND REPLACEMENT OF SUCH UTILITY SERVICES LINES, TOGETHER WITH A REASONABLE RIGHT OF ACCESS FOR THE ACCOMPLISHMENT OF SUCH PURPOSES AND TOGETHER WITH A REASONABLE RIGHT OF ACCESS FOR THE PURPOSE OF RELOCATING SAID UTILITY SERVICE LINES; ASC AND ITS SUCCESSORS RESERVES THE RIGHT, EXCEPT IN THE CASE OF A BONA FIDE EMERGENCY, TO TEMPORARILY DENY THE OWNER OF LOT 1 AND ITS SUCCESSORS, ASSIGNS, EMPLOYEES, LICENSEES, AND INVITEES ACCESS TO THE UTILITY SERVICE LINE EASEMENT DURING THE SKI SEASON TO ACCOMMODATE SNOWMAKING, SNOW STORAGE, SNOW GROOMING, SKIING AND OTHER WINTER SKI OPERATIONS; AND 12.DOES HEREBY DEDICATE AND GRANT TO THE GENERAL PUBLIC THE LIMITED, NON-EXCLUSIVE RIGHT TO USE THE MOUNTAIN OPERATIONS ROAD PRIVATE EASEMENT OUTSIDE OF THE SKI SEASON FOR PEDESTRIAN AND BICYCLE USES; SUCH GRANT IS EXPRESSLY MADE SUBJECT TO ASC’S RIGHTS, EXERCISED IN ITS SOLE DISCRETION, TO CONTROL AND MANAGE AND/OR ENFORCE CLOSURES OF THE MOUNTAIN OPERATIONS ROAD IN CONNECTION WITH ASPEN MOUNTAIN SKI AREA OPERATIONS AT ANY TIME AS DETERMINED BY THE OPERATOR OF ASPEN MOUNTAIN SKI AREA FOR SAFETY, MAINTENANCE, OPERATIONS, LOADING, UNLOADING AND STAGING PURPOSES AND/OR AS CONTEMPLATED UNDER THE ASPEN MOUNTAIN SKI AREA MASTER PLAN, AS AMENDED FROM TIME TO TIME. IN CONNECTION WITH THE EXERCISE OF ANY RIGHT UNDER AND USE OF ANY EASEMENT GRANTED OR RESERVED BY THIS CERTIFICATE, THE OWNER (OF LOT 1 OR LOT 2 AS THE CASE MAY BE) EXERCISING SUCH RIGHT SHALL INDEMNIFY AND HOLD HARMLESS THE OTHER OWNER (OF LOT 1 OR 2, AS THE CASE MAY BE) FROM ANY CLAIMS, DEMAND, SUIT, JUDGMENT, LIEN OR DAMAGES OF ANY NATURE ARISING OUT OF SUCH OWNER’S RIGHT, EXERCISE OR USE, INCLUDING REASONABLE ATTORNEYS FEES AND COSTS INCURRED IN CONNECTION THEREWITH; AND THE OWNERS OF LOTS 1 AND 2 SHALL EACH AT ALL TIMES MAINTAIN A COMMERCIAL LIABILITY INSURANCE POLICY WITH AN INSURANCE COMPANY WITH A BEST’S RATING OF $_________, AND WITH MINIMUM LIMITS OF . EXECUTED THIS____ DAY OF ________________, 2020. ASPEN SKIING COMPANY, LLC, A COLORADO LIMITED LIABILITY COMPANY BY:____________________________________________________________ ___________________, ITS MANAGER STATE OF COLORADO ) ) SS. COUNTY OF PITKIN ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS ______ DAY OF ____________, 2020 BY _____________________ AS ____________________ OF ASPEN SKIING COMPANY, LLC. WITNESS MY HAND AND OFFICIAL SEAL MY COMMISSION EXPIRES _________ TITLE COMPANY CERTIFICATE THE UNDERSIGNED, A DULY-AUTHORIZED REPRESENTATIVE OF LAND TITLE GUARANTEE COMPANY, REGISTERED TO DO BUSINESS IN PITKIN COUNTY, COLORADO, DOES HEREBY CERTIFY, PURSUANT TO SECTION 20-15(J) OF THE ASPEN MUNICIPAL CODE, THAT ASPEN SKIING COMPANY DOES HOLD FEE SIMPLE TITLE TO THE REAL PROPERTY DESCRIBED HEREIN AND IS FREE AND CLEAR OF ALL LIENS AND ENCUMBRANCES EXCEPT THOSE LISTED ON THE TITLE COMMITMENT ISSUED BY LAND TITLE GUARANTEE COMPANY UNDER ORDER NO. QC62010933, DATED JANUARY 10, 2020. ALTHOUGH WE BELIEVE THE FACTS STATED ON THIS PLAT ARE TRUE, THIS CERTIFICATE IS NOT TO BE CONSTRUED AS AN ABSTRACT OF TITLE, NOR AN OPINION OF TITLE, NOR A GUARANTY OF TITLE, AND IT IS UNDERSTOOD AND AGREED THAT LAND TITLE GUARANTEE COMPANY, NEITHER ASSUMES NOR WILL BE CHARGED WITH ANY FINANCIAL OBLIGATION OR LIABILITY WHATEVER ON ANY STATEMENT CONTAINED HEREIN. BY:_________________________________DATE______________ NAME, TITLE ADDRESS: 533 E. HOPKINS AVENUE ASPEN, CO 81611 STATE OF COLORADO ) )SS. COUNTY OF PITKIN ) THE TITLE CERTIFICATE WAS ACKNOWLEDGED BEFORE ME THIS __________ DAY OF ____________________, 2020, BY ____________________________ AS __________________ OF LAND TITLE GUARANTEE COMPANY NAME WITNESS MY HAND AND OFFICIAL __________________________________________ NOTARY PUBLIC MY COMMISSION EXPIRES: _______________________. MY ADDRESS IS: _______________________________. 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0200 200 400 200 800100 VICINITY MAP SCALE: 1" = 2000' SITE SURVEYOR'S CERTIFICATE I, MARK S. BECKLER, A PROFESSIONAL LAND SURVEYOR LICENSED IN THE STATE OF COLORADO, HEREBY CERTIFY THAT IN MAY-JUNE 2018, A SURVEY OF THE HEREIN DESCRIBED PROPERTY WAS PERFORMED UNDER MY SUPERVISION AND DIRECTION, IN ACCORDANCE WITH COLORADO REVISED STATUTES 1973, TITLE 38, ARTICLE 51, AS AMENDED FROM TIME TO TIME, AND THAT THIS FINAL PLAT OF GORSUCH HAUS PD/SUBDIVISION ACCURATELY AND SUBSTANTIALLY DEPICTS SAID SURVEY. THE CONTROL SURVEY PRECISION IS GREATER THAN 1/15,000. RECORDED EASEMENTS, RIGHTS-OF-WAY AND RESTRICTIONS ARE THOSE SET FORTH IN THE TITLE COMMITMENT REFERENCED IN SURVEY NOTE 5 HEREON. ______________________________________________ MARK S. BECKLER, PLS #28643 COMMUNITY DEVELOPMENT DEPARTMENT DIRECTOR REVIEW THIS FINAL PLAT OF GORSUCH HAUS PD/SUBDIVISION WAS REVIEWED BY THE COMMUNITY DEVELOPMENT DIRECTOR OF THE CITY OF ASPEN THIS ______ DAY OF ______________________, 2020. _______________________________ DIRECTOR CITY ENGINEER'S CERTIFICATE THIS FINAL PLAT OF GORSUCH HAUS PD/SUBDIVISION WAS REVIEWED FOR THE DEPICTION OF THE ENGINEERING DEPARTMENT SURVEY REQUIREMENTS THIS ________________ DAY OF ___________________ , 2020. ________________________________ CITY ENGINEER ASPEN CITY COUNCIL APPROVAL THIS FINAL PLAT OF GORSUCH HAUS PD/SUBDIVISION WAS APPROVED BY THE CITY OF ASPEN CITY COUNCIL ON THE ______ DAY OF ____________________, 20___, BY ORDINANCE NO. _____, SERIES OF 2020, RECORDED _______________, 2020 IN THE OFFICE OF THE CLERK AND RECORDER OF PITKIN COUNTY AS RECEPTION NO. ___________________ AND THE CITY OF ASPEN HEREBY SPECIFICALLY CONFIRMS FOR THE BENEFIT OF ASPEN SKIING COMPANY LLC THAT CERTAIN EASEMENT OVER AND ACROSS HILL STREET AS MORE PARTICULARLY DESCRIBED IN THE EASEMENT AGREEMENT RECORDED AS RECEPTION NO.____________, PURSUANT TO CITY OF ASPEN CITY COUNCIL ORDINANCE NO._______________, RECORDED AS RECEPTION NO. ___________, AND AS SHOWN ON SHEET 4 HEREON. ______________________________________________________ MAYOR, TORRE DATE ATTEST: _____________________________ CITY CLERK SHEET INDEX SHEET 1 -DEDICATION, CERTIFICATES, AND CONTROL DIAGRAM SHEET 2 -OVERVIEW OF GORSUCH HAUS SUBJECT PROPERTIES, PROPERTY DESCRIPTIONS, EASEMENTS AND SURVEY NOTES SHEET 3 -RIGHT-OF-WAY DEDICATION, SUBDIVISION LOT DIMENSIONS AND RECORD EASEMENTS SHEET 4 -SUBDIVISION EASEMENTS CONTROL DIAGRAM CITY OF ASPEN CONFIRMATION OF RECREATIONAL USE EASEMENT GRANT HILL STREET RIGHT OF WAY PURSUANT TO CITY OF ASPEN CITY COUNCIL ORDINANCE NO. 39, AND AS FURTHER CONFIRMED IN THAT CERTAIN EASEMENT AGREEMENT RECORDED AS RECEPTION NO._____________________ IN THE PITKIN COUNTY RECORDS, THE CITY OF ASPEN HEREBY GRANTS AND CONFIRMS FOR THE USE AND BENEFIT OF ASPEN SKIING COMPANY, LLC, ITS SUCCESSORS, ASSIGNS, AFFILIATES, AGENTS, CONTRACTORS AND EMPLOYEES, AS OPERATOR AND MANAGER OF THE LIFT FACILITIES AND AS OPERATOR AND MANAGER OF THE ASPEN MOUNTAIN SKI AREA, A PERPETUAL, NON-EXCLUSIVE, PRIVATE RECREATIONAL USE EASEMENT ACROSS, OVER, UNDER AND UPON THAT PORTION OF HILL STREET DEPICTED ON SHEET 4 HEREOF AND LABELED “RECREATIONAL USE EASEMENT” FOR THE USE AND BENEFIT OF THE ASPEN SKIING COMPANY AND ITS AFFILIATES, AGENTS, CONTRACTORS, EMPLOYEES, LICENSEES AND INVITEES, FOR THE PURPOSES OF INGRESS AND EGRESS TO AND USE AND ENJOYMENT OF THE SKI LIFT FACILITIES, SKI TRAIL, SKI OPERATIONS AND OTHER SKI RELATED INFRASTRUCTURE AND FACILITIES, AND FOR CONSTRUCTING, INSTALLING, ENLARGING, OPERATING, MAINTAINING, REPAIRING, REMOVING AND REPLACING LIFT FACILITIES. THE ACTUAL LOCATION OF SAID RECREATIONAL USE EASEMENT SHALL BE DEEMED AUTOMATICALLY AMENDED TO COINCIDE WITH THE AS-BUILT LOCATION OF THE SKIWAY AND AERIAL LIFT FACILITY AS IT AFFECTS THE HILL STREET RIGHT OF WAY. THE CITY OF ASPEN, A COLORADO HOME RULE MUNICPALITY BY: _____________________ ___________________ TORRE, MAYOR DATE ATTEST:_____________________________ CITY CLERK GOV'T LO T 3 1 (WITHIN A S P E N CITY LIM I T S ) CENTERLINE 15' WIDE WATER PIPELINE EASEMENT BK 412 PG 557 VACATED BY THE STREET AND EASEMENT VACATION PLAT REC. #___________ CENTERLINE 15' WIDE DRAINAGE EASEMENT BK 291 PG 649 VACATED BY SEPARATE INSTRUMENT RECORDED AS REC #_________________ PUBLIC SIDEWALK, UTILITY AND SNOW STORAGE EASEMENT REC #597440 25' WIDE EASEMENT FOR SKIERS AND PEDESTRIANS PLAT BK 4 PG 489 AND WATERLINE EASEMENT TO CITY OF ASPEN BK 411 PG 996 20' WIDE EASEMENT FOR FIRE ACCESS AND DRAINAGE GRANTED TO MOUNTAIN QUEEN CONDOS BK 275 PG 378 AND WATERLINE EASEMENT GRANTED TO CITY OF ASPEN BK 291 PG 649 SKI CORRIDOR EASEMENT REC #597440 SHADOW MOUNTAIN VILLAGECONDOMINIUMSPLAT BK. 3 PG. 33 LOT 2 SOUTH ASPEN STREET SUBDIVISION/PUD,1ST AMENDEDREC. #616166 (A/K/A ONE ASPEN) MOUNTAIN QUEENCONDOMINIUMSPLAT BK. 4 PG. 489 CONSERVATION PARCELBARBEE FAMILY SUBDIVISION, FIRST AMENDEDREC. #461107CITY OF ASPEN LOT 1LIFT ONE LODGE SUBDVISION/PUDREC. #597438 LOT 3LIFT ONE LODGE SUBDVISION/PUDREC. #597438 CARIBOUCONDOMINIUMSPLAT BK. 94 PG. 52 PARCEL 2 10,917 SQ FT 0.251 ACRES PARCEL C 1,827 SQ FT 0.042 ACRES PARCEL D 1,825 SQ FT 0.042 ACRES PARCEL 3 2,973 SQ FT 0.068 ACRES PARCEL B 2,592 SQ FT 0.060 ACRES CITY OF ASPEN PITKIN COUNTY AREA SUBJECT TO PARAGRAPH 4 "TEMPORARY CONSTRUCTION EASEMENTS AND PERMANENT ENCROACHMENT EASEMENTS" PER THE MASTER EASEMENT AGREEMENT RECORDED AS REC. #597440 PARCEL 4 240,375 SQ FT 5.518 ACRES 50' SETBACK BUILDING RESTRICTION BK 231 PG 278 PARCEL A 1,917 SQ FT 0.044 ACRES GOV'T LO T 3 1 (WITHIN A S P E N CITY LIM I T S ) S70° 03' 10"E1.01' S 1 1 ° 2 5 ' 3 0 " E 1 1 0 . 7 7 ' 10.00' S75° 09' 11"E 182.60' 10.00' N75° 09' 11"W 182.44' 10.00'10.00' S14° 50' 49"W 63.83' S89° 55' 06"W38.97' N14° 50' 49"E 73.87' PARCEL 1 23,897 SQ FT 0.549 ACRES N38° 38' 25"E 72.34' N45° 13' 35"W 33.86' N14° 42' 57"E 30.93' 598.23' S14° 50' 49"W6.17' S75° 09' 11"E 181.46' 5 4 . 7 9 ' N89° 55' 0 6 " E 53.70' S4 5 ° 0 0 ' 0 0 " W 2 8 7 . 8 1 ' N70° 37' 00"W 757.26' N14° 40' 15"E 35.71' S 1 1 ° 2 5 ' 3 0 " E 1 9 7 . 7 5 ' N14° 50' 49"E 51.97' N78° 21' 58"W 37.71' S14° 50' 49"W 49.86' 37.65' S75° 09' 11"E 182.76' 13 0 . 0 2 ' N75° 09' 11"W 184.89' N89° 55' 0 6 " E 5 5 9 . 2 6 ' N1 4 ° 5 0 ' 4 9 " E 8 8 . 0 3 ' 60 . 0 1 ' GOV'TLOT 38 TOP OF MILL SUBDIVISIONREC. #471099 HILL STREET R.O.W. SOUTH ASPEN STREETR.O.W. 41 . 9 6 ' 25 . 0 0 ' AREA OF REVOCABLE ENCROACHMENT LICENSE AGREEMENT REMAINING BETWEEN CITY OF ASPEN AND SHADOW MOUNTAIN VILLAGE CONDOMINIUMS REC. #543674 FOUND #5 REBAR AND 1.25" PLASTIC CAP L.S. 28643 FOUND #5 REBAR AND 114" PLASTIC CAP L.S. #25947 FOUND SPIKE FOUND SPIKE FOUND #5 REBARFOUND #5 REBAR AND 1.25" PLASTIC CAP L.S. #ILLEGIBLE (BENT) CORNER BEARS S.67°16'28"E. 1.38' FOUND PK NAIL IN PAVEMENT CORNER BEARS S65°53'16"E 1.23' FOUND #5 REBAR AND 1.25" PLASTIC CAP L.S. #28643 FOUND #5 REBAR AND 1.25" PLASTIC CAP L.S. #28643 FOUND #5 REBAR AND 114" PLASTIC CAP L.S. #ILLEGIBLE FOUND #5 REBAR AND 114" PLASTIC CAP L.S. #9184 POINT OF BEGINNING PARCEL 4 BA S I S O F B E A R I N G FINAL PLAT OF: SHEET 2 OF 4 OVERVIEW OF GORSUCH HAUS SUBJECT PROPERTIES, PROPERTY DESCRIPTIONS, EASEMENTS AND SURVEY NOTES GORSUCH HAUS PD/SUBDIVISION A PARCEL OF LAND SITUATED IN THE NE1 4 OF SECTION 13, TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE 6th P.M., CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO THE PURPOSE OF THIS PLAT IS TO CREATE A PLANNED DEVELOPMENT (PD), REZONE, AND SUBDIVIDE THE SUBJECT PROPERTY NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. SOPRIS ENGINEERING - LLC CIVIL CONSULTANTS 502 MAIN STREET, SUITE A3 CARBONDALE, COLORADO 81623 (970) 704-0311 CL sb 13139.01 02/26/2020 G:\2013\13139\SURVEY\Survey DWGs\Survey Plots\13139-SUBDIVISION.dwg 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 040 40 80 40 16020 PROPERTY DESCRIPTION ASPEN SKIING COMPANY, LLC PROPERTY: [FROM THE TITLE COMMITMENT PREPARED BY LAND TITLE GUARANTEE COMPANY UNDER ORDER NO. QC62010933, DATED JANUARY 10, 2020] PARCEL 1 LOTS 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 AND 14, BLOCK 10, EAMES ADDITION TO THE CITY OF ASPEN PARCEL 2 LOTS 1, 2, 3, 4, 5, 6 AND 7, BLOCK 12, EAMES ADDITION TO THE CITY OF ASPEN PARCEL 3 A PARCEL OF LAND BEING A PORTION OF THAT PROPERTY DESCRIBED IN THE DOCUMENT RECORDED JULY 15, 1985 AS RECEPTION NO. 156038 IN BOOK 270 AT PAGE 21 OF THE PITKIN COUNTY RECORDS AND THAT PROPERTY DESCRIBED IN THE DOCUMENT RECORDED JULY 13, 1971 AS RECEPTION NO. 146439 IN BOOK 256 AT PAGE 506; SAID PARCEL OF LAND ALSO BEING SITUATED IN GOVERNMENT LOT 1 IN SECTION 13, TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE SIXTH PRINCIPAL MERIDIAN; SAID PARCEL BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE EASTERLY BOUNDARY LINE OF BLOCK 10 EAMES ADDITION TO THE CITY OF ASPEN, WHENCE THE NORTHEAST CORNER OF LOT 7 OF SAID BLOCK 10 BEARS N.15°46'58"E. A DISTANCE OF 41.96 FEET; SAID POINT ALSO BEING THE SOUTHWEST CORNER OF CARIBOU CONDOMINIUMS, ACCORDING TO THE MAP THEREOF RECORDED APRIL 24, 1973 IN PLAT BOOK 4 AT PAGE 379; THENCE S.70°03'10"E. ALONG THE SOUTHERLY BOUNDARY LINE OF SAID CARIBOU CONDOMINIUMS A DISTANCE OF 1.01 FEET TO THE NORTHWEST CORNER OF MOUNTAIN QUEEN CONDOMINIUMS, ACCORDING TO THE MAP THEREOF RECORDED SEPTEMBER 27, 1974 IN PLAT BOOK 4 AT PAGE 489; THENCE LEAVING SAID SOUTHERLY BOUNDARY LINE OF SAID CARIBOU CONDOMINIUMS S.11°25'30"E. ALONG THE WESTERLY BOUNDARY LINE OF SAID MOUNTAIN QUEEN CONDOMINIUMS A DISTANCE OF 110.77 FEET TO A POINT ON THE SOUTH LINE OF SAID GOVERNMENT LOT 1; THENCE LEAVING SAID WESTERLY BOUNDARY LINE OF SAID MOUNTAIN QUEEN CONDOMINIUMS S.89°55'06"W. ALONG SAID SOUTH LINE OF SAID GOVERNMENT LOT 1 A DISTANCE OF 43.70 FEET TO A POINT ON THE EASTERLY BOUNDARY LINE OF BLOCK 12 EAMES ADDITION TO THE CITY OF ASPEN; THENCE LEAVING SAID SOUTH LINE OF SAID GOVERNMENT LOT 1 N.15°46'58"E. ALONG THE EASTERLY BOUNDARY LINE OF SAID BLOCK 12 EAMES ADDITION A DISTANCE OF 4.21 FEET TO THE NORTHEAST CORNER OF SAID BLOCK 12 EAMES ADDITION, SAID POINT ALSO BEING THE SOUTHEAST CORNER OF SUMMIT STREET RIGHT OF WAY; THENCE CONTINUING N.15°46'58"E. ALONG THE EASTERLY LINE OF SAID RIGHT OF WAY A DISTANCE OF 20.00 FEET TO THE SOUTHEAST CORNER OF SAID BLOCK 10 EAMES ADDITION; THENCE CONTINUING N.15°46'58"E. ALONG THE EASTERLY BOUNDARY LINE OF SAID BLOCK 10 EAMES ADDITION A DISTANCE OF 88.05 FEET TO THE POINT OF BEGINNING. SAID PARCEL OF LAND CONTAINING 2,973 SQUARE FEET OR 0.068 ACRES, MORE OR LESS. PARCEL 4 A PARCEL OF LAND BEING A PORTION OF THAT PROPERTY DESCRIBED IN THE DOCUMENT RECORDED DECEMBER 19, 1946 AS RECEPTION NO. 094502 OF THE PITKIN COUNTY RECORDS; SAID PARCEL OF LAND ALSO BEING SITUATED IN GOVERNMENT LOT 31 IN SECTION 13, TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE SIXTH PRINCIPAL MERIDIAN AS DESCRIBED BY THE DEPENDENT RESURVEY AND SURVEY PLAT OF TOWNSHIP 10 SOUTH, RANGE 85 WEST, OF THE SIXTH PRINCIPAL MERIDIAN, FILED MAY 30, 1980 IN THE UNITED STATES DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT OFFICE IN DENVER, COLORADO ("BLM PLAT"); SAID PARCEL OF LAND IS LOCATED ENTIRELY WITHIN THE CITY LIMITS OF THE CITY OF ASPEN AND IS MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE WESTERLY BOUNDARY LINE OF MOUNTAIN QUEEN CONDOMINIUMS, ACCORDING TO THE MAP THEREOF RECORDED SEPTEMBER 27, 1974 IN PLAT BOOK 4 AT PAGE 489, WHENCE THE NORTHWEST CORNER OF SAID MOUNTAIN QUEEN CONDOMINIUMS BEARS N.11°25'30"W. A DISTANCE OF 110.77 FEET; THENCE S.11°25'30"E. ALONG SAID WESTERLY BOUNDARY LINE OF MOUNTAIN QUEEN CONDOMINIUMS A DISTANCE OF 197.75 FEET; THENCE CONTINUING ALONG SAID WESTERLY BOUNDARY LINE S.45°00'00"W. A DISTANCE OF 6.42 FEET TO THE SOUTHWEST CORNER OF SAID MOUNTAIN QUEEN CONDOMINIUMS; THENCE LEAVING SAID WESTERLY BOUNDARY LINE S.45°00'00"W. ALONG THE EAST LINE OF SAID GOVERNMENT LOT 31 A DISTANCE OF 281.39 FEET TO A POINT ON THE SOUTHERLY BOUNDARY LINE OF THE SOUTH ANNEXATION TO THE CITY OF ASPEN, COLO, ACCORDING TO THE MAP THEREOF RECORDED MARCH 24, 1967 IN PLAT BOOK 3 AT PAGE 132; THENCE LEAVING SAID EAST LINE OF SAID GOVERNMENT LOT 31 N.70°37'00"W. ALONG THE SOUTHERLY BOUNDARY LINE OF SAID SOUTH ANNEXATION TO THE CITY OF ASPEN A DISTANCE OF 757.26 FEET TO A POINT ON THE WEST LINE OF SAID GOVERNMENT LOT 31; THENCE N.14°40'13"E. A DISTANCE OF 35.71 FEET TO THE SOUTHERLY MOST POINT OF GOVERNMENT LOT 38, ACCORDING TO SAID "BLM PLAT"; THENCE ALONG THE COMMON LINE BETWEEN SAID GOVERNMENT LOT 31 AND SAID GOVERNMENT LOT 38 THE FOLLOWING TWO (2) COURSES: 1) N.38°38'25"E. A DISTANCE OF 72.34 FEET 2) N.45°13'35"W. A DISTANCE OF 33.86 FEET; THENCE LEAVING THE EAST LINE OF SAID GOVERNMENT LOT 38, CONTINUING ALONG THE WEST LINE OF SAID GOVERNMENT LOT 31 N.14°42'57"E. A DISTANCE OF 30.93 FEET TO A POINT ON THE NORTH LINE OF THE SE1/4NE1/4 OF SECTION 13, ALSO BEING A POINT ON THE NORTH LINE OF SAID GOVERNMENT LOT 31; THENCE LEAVING SAID WEST LINE OF SAID GOVERNMENT LOT 31 N.89°55'06"E. ALONG THE NORTH LINE OF THE SE1/4NE1/4 OF SECTION 13, ALSO BEING THE NORTH LINE OF SAID GOVERNMENT LOT 31, A DISTANCE OF 498.23 FEET TO A POINT ON THE WESTERLY BOUNDARY LINE OF BLOCK 12, EAMES ADDITION TO THE CITY OF ASPEN THENCE LEAVING SAID NORTH LINES S.14°50'49"W. ALONG THE WESTERLY BOUNDARY LINE OF SAID BLOCK 12 EAMES ADDITION A DISTANCE OF 6.17 FEET TO THE SOUTHWEST CORNER OF SAID BLOCK 12 EAMES ADDITION; THENCE LEAVING SAID WESTERLY BOUNDARY LINE OF SAID BLOCK 12 EAMES ADDITION S.75°09'11"E. ALONG THE SOUTHERLY BOUNDARY LINE OF SAID BLOCK 12 EAMES ADDITIONS A DISTANCE OF 181.46 FEET TO THE SOUTHEAST CORNER OF SAID BLOCK 12 EAMES ADDITION; THENCE N.15°46'58"E. ALONG THE EASTERLY BOUNDARY LINE OF SAID BLOCK 12 EAMES ADDITION A DISTANCE OF 44.79 FEET TO A POINT ON SAID NORTH LINE OF SAID SE1/4NE1/4 OF SECTION 13, SAID POINT ALSO BEING A POINT ON THE NORTH LINE OF SAID GOVERNMENT LOT 31; THENCE LEAVING SAID EASTERLY BOUNDARY LINE OF SAID BLOCK 12 EAMES ADDITION N.89°55'06"E. ALONG THE NORTH LINE OF THE SE1/4NE1/4 OF SECTION 13, ALSO BEING THE NORTH LINE OF SAID GOVERNMENT LOT 31, A DISTANCE OF 43.70 FEET TO THE POINT OF BEGINNING. SAID PARCEL OF LAND CONTAINING 240,375 SQUARE FEET OR 5.518 ACRES, MORE OR LESS. CITY OF ASPEN COUNTY OF PITKIN STATE OF COLORADO RIGHTS OF WAY VACATED BY ORDINANCE NO. ___ SERIES OF 2020, AS SHOWN IN THAT STREET AND EASEMENT VACATION PLAT RECORDED IN PLAT BOOK _______________ AT PAGE ___________ AS RECEPTION NUMBER _______________ (DEPICTED HEREON AS PARCELS A, B, C, AND D). ALL THE FOREGOING PROPERTY TO BE COLLECTIVELY REFERENCED HEREIN AS THE “SUBJECT PROPERTY" HATCH LEGEND ROW VACATED BY STREET AND EASEMENT VACATION PLAT RECORDED ______________________, 20___ IN PLAT BOOK _______________ AT PAGE ___________ AS RECEPTION NUMBER _______________. AREA OF REVOCABLE ENCROACHMENT LICENSE AGREEMENT BETWEEN CITY OF ASPEN AND SHADOW MOUNTAIN VILLAGE CONDOMINIUMS REC. #543674; PORTIONS OF WHICH REVOKED BY STREET AND EASEMENT VACATION PLAT RECORDED ______________________, 20___ IN PLAT BOOK _______________ AT PAGE ___________ AS RECEPTION NUMBER _______________. SURVEY NOTES 1)DATE OF FIELD WORK: AUGUST - SEPTEMBER 2005; UPDATED MAY 2006, JUNE AND JULY 2007, OCTOBER - DECEMBER 2008, SEPTEMBER 2009, AND MARCH 2010; UPDATED AUGUST 2013; UPDATED AUGUST 2014; UPDATED JULY - SEPTEMBER 2015; UPDATED MAY 2018; UPDATED JANUARY 2020 2)DATE OF PREPARATION: NOVEMBER - DECEMBER 2015; FEBRUARY 2016; UPDATED AUGUST - SEPTEMBER 2016; UPDATED MAY - JUNE 2018; UPDATED JANUARY AND FEBRUARY 2020 3)BASIS OF BEARING: A BEARING OF N 14°50'49" E BETWEEN THE SOUTHEAST CORNER OF SHADOW MOUNTAIN VILLAGE, A FOUND REBAR AND CAP L.S. #25947, AND THE SOUTHEAST CORNER OF SOUTH ASPEN STREET SUBDIVISION, A FOUND REBAR & CAP LS #28643. 4)BASIS OF SURVEY: THE 1896 W. C. WILLITS MAP OF ASPEN, COLORADO, THE OFFICIAL MAP OF THE CITY OF ASPEN PREPARED BY G.E. BUCHANAN DATED DECEMBER 15, 1959, THE SOUTH ANNEXATION TO THE CITY OF ASPEN APPROVED BY ORDINANCE NO. 4, DATED MARCH 20, 1967 RECORDED IN PLAT BOOK 3 AT PAGE 132, THE 2009 GPS CONTROL MONUMENTATION MAP FOR THE CITY OF ASPEN PREPARED BY MARCIN ENGINEERING LLC REVISED JULY 13, 2010, THE PLAT OF LIFT ONE LODGE SUBDIVISION, RECORDED MARCH 5, 2013, THE STREET, ALLEYWAY AND EASEMENT VACATION PLAT RECORDED MARCH 5, 2013 UNDER RECEPTION NO. 597435, THE PLAT OF SOUTH ASPEN STREET SUBDIVISION RECORDED APRIL 27, 2007 UNDER RECEPTION NO. 537080, THE FIRST AMENDED PLAT OF SOUTH ASPEN STREET SUBDIVISION RECORDED DECEMBER 19, 2014 AS RECEPTION NO. 616166, THE CONDOMINIUM MAP OF MOUNTAIN QUEEN CONDOMINIUMS RECORDED SEPTEMBER 27, 1974 IN PLAT BOOK 4 AT PAGE 489, THE CONDOMINIUM MAP OF CARIBOU CONDOMINIUMS RECORDED SEPTEMBER 8, 2009 IN PLAT BOOK 4 AT PAGE 379, THE CONDOMINIUM MAP OF SHADOW MOUNTAIN VILLAGE RECORDED JULY 12, 1965 IN PLAT BOOK 3 AT PAGE 33, THE AMENDED PLAT OF BARBEE FAMILY SUBDIVISION/PUD RECORDED NOVEMBER 21, 2001 IN PLAT BOOK 59 AT PAGE 222,THE STREET AND EASEMENT VACATION PLAT RECORDED _________________, 2020 AS RECEPTION NO. _______________, DOCUMENTS OF RECORD AND THE FOUND SURVEY MONUMENTS, AS SHOWN. 5) THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH BY SOPRIS ENGINEERING, LLC (SE) TO DETERMINE OWNERSHIP OR EASEMENTS OF RECORD. FOR ALL INFORMATION REGARDING EASEMENTS, RIGHTS OF WAY AND/OR TITLE OF RECORD, SE RELIED UPON THE ABOVE SAID ITEMS DESCRIBED IN NOTE 4 AND THE TITLE COMMITMENT PREPARED BY LAND TITLE GUARANTEE COMPANY UNDER ORDER NO. QC62010933, DATED JANUARY 10, 2020. 6)THE LINEAR UNIT USED IN THE PREPARATION OF THIS PLAT IS THE U.S. SURVEY FOOT AS DEFINED BY THE UNITED STATES DEPARTMENT OF COMMERCE, NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY. PARENTING PARCELS PARCEL AREA (SQ.FT.)AREA (ACRES) PARCEL 1 23,897 0.549 PARCEL 2 10,917 0.251 PARCEL 3 2,973 0.068 PARCEL 4 240,375 5.518 PARCEL A 1,917 0.044 PARCEL B 2,592 0.060 PARCEL C 1,827 0.042 PARCEL D 1,825 0.042 TOTAL 286,323 6.573 RESULTING SUBDIVISION PARCELS PARCEL AREA (SQ.FT.)AREA (ACRES) LOT 1 44,545 1.023 LOT 2 238,065 5.471 DEDICATED ROW 3,713 0.079 TOTAL 286,323 6.573 PUBLIC SIDEWALK, UTILITY AND SNOW STORAGE EASEMENT REC #597440 25' WIDE EASEMENT FOR SKIERS AND PEDESTRIANS PLAT BK 4 PG 489 AND WATERLINE EASEMENT TO CITY OF ASPEN BK 411 PG 996 20' WIDE EASEMENT FOR FIRE ACCESS AND DRAINAGE GRANTED TO MOUNTAIN QUEEN CONDOS BK 275 PG 378 AND WATERLINE EASEMENT GRANTED TO CITY OF ASPEN BK 291 PG 649 SKI CORRIDOR EASEMENT REC #597440 SHADOW MOUNTAIN VILLAGECONDOMINIUMSPLAT BK. 3 PG. 33 LOT 2 SOUTH ASPEN STREET SUBDIVISION/PUD,1ST AMENDEDREC. #616166 (A/K/A ONE ASPEN) MOUNTAIN QUEENCONDOMINIUMSPLAT BK. 4 PG. 489 CONSERVATION PARCELBARBEE FAMILY SUBDIVISION, FIRST AMENDEDREC. #461107CITY OF ASPEN LOT 1LIFT ONE LODGE SUBDVISION/PUDREC. #597438 LOT 3LIFT ONE LODGE SUBDVISION/PUDREC. #597438 CARIBOUCONDOMINIUMSPLAT BK. 94 PG. 52 CITY OF ASPEN PITKIN COUNTY 50' SETBACK BUILDING RESTRICTION BK 231 PG 278 GOV'TLOT 38 TOP OF MILL SUBDIVISIONREC. #471099 S75° 09' 11"E HILL STREET R.O.W. SOUTH ASPEN STREETR.O.W. AREA OF REVOCABLE ENCROACHMENT LICENSE AGREEMENT REMAINING BETWEEN CITY OF ASPEN AND SHADOW MOUNTAIN VILLAGE CONDOMINIUMS REC. #543674 LOT 2238,065 SQ FT±5.465 ACRES± DEDICATED ROW 3,713 SQ FT± 0.085 ACRES± LOT 144,545 SQ FT±1.023 ACRES± BA S I S O F B E A R I N G FINAL PLAT OF: SHEET 3 OF 4 RIGHT-OF-WAY DEDICATION, SUBDIVISION LOT DIMENSIONS AND RECORD EASEMENTS GORSUCH HAUS PD/SUBDIVISION A PARCEL OF LAND SITUATED IN THE NE1 4 OF SECTION 13, TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE 6th P.M., CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO THE PURPOSE OF THIS PLAT IS TO CREATE A PLANNED DEVELOPMENT (PD), REZONE, AND SUBDIVIDE THE SUBJECT PROPERTY NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. SOPRIS ENGINEERING - LLC CIVIL CONSULTANTS 502 MAIN STREET, SUITE A3 CARBONDALE, COLORADO 81623 (970) 704-0311 CL sb 13139.01 02/26/2020 G:\2013\13139\SURVEY\Survey DWGs\Survey Plots\13139-SUBDIVISION.dwg 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 040 40 80 40 16020 HATCH LEGEND DEDICATED SOUTH ASPEN STREET RIGHT-OF-WAY (SEE DEDICATION PARAGRAPH 1) AREA OF REVOCABLE ENCROACHMENT LICENSE (REC. #543674) AREA OF CITY OF ASPEN RIGHT-OF-WAY FOR SOUTH ASPEN STREET PER THIS PLAT PARENTING PARCELS PARCEL AREA (SQ.FT.)AREA (ACRES) PARCEL 1 23,897 0.549 PARCEL 2 10,917 0.251 PARCEL 3 2,973 0.068 PARCEL 4 240,375 5.518 PARCEL A 1,917 0.044 PARCEL B 2,592 0.060 PARCEL C 1,827 0.042 PARCEL D 1,825 0.042 TOTAL 286,323 6.573 RESULTING SUBDIVISION PARCELS PARCEL AREA (SQ.FT.)AREA (ACRES) LOT 1 44,545 1.023 LOT 2 238,065 5.471 DEDICATED ROW 3,713 0.079 TOTAL 286,323 6.573 SUBSURFACE STRUCTURAL EASEMENT (SEE DEDICATION PARAGRAPH 4) 37.65' SOUTH ASPEN STREET ROW PUBLIC SIDEWALK, UTILITY AND SNOW STORAGE EASEMENT REC. #597440 SKI CORRIDOR EASEMENT REC. #597440 PUBLIC PEDESTRIAN EASEMENT WIDTH VARIES (SEE DEDICATION PARAGRAPH 6) MOUNTAIN OPERATIONS ROAD PRIVATE EASEMENT FOR PEDESTRIAN AND BICYCLE USES (SEE DEDICATION PARAGRAPH 12) TEMPORARY RECIPROCAL CONSTRUCTION EASEMENT (SEE DEDICATION PARAGRAPH 3) 5' PUBLIC TRAIL EASEMENT (SEE DEDICATION PARAGRAPH 2) UTILITY EASEMENT (SEE DEDICATION PARAGRAPH 8) AREA SUBJECT TO "TEMPORARY CONSTRUCTION EASEMENTS AND PERMANENT ENCROACHMENT EASEMENTS," PER PARAGRAPH 4 OF THE MASTER EASEMENT AGREEMENT, RECORDED MARCH 5, 2013 AS REC. #597440 AREA OF REVOCABLE ENCROACHMENT LICENSE GRANTED TO SHADOW MOUNTAIN VILLAGE APARTMENTS REC. #543674 SUBSURFACE STRUCTURAL EASEMENT (SEE DEDICATION PARAGRAPH 4) EASEMENT GRANTED BY MOUNTAIN QUEEN CONDOS FOR SKIERS AND PEDESTRIANS PLAT BK.4 PG.489 AND WATERLINE EASEMENT TO CITY OF ASPEN BK. 411 PG. 996 EASEMENT FOR FIRE ACCESS AND DRAINAGE GRANTED TO MOUNTAIN QUEEN CONDOS BK.275 PG.378 AND WATERLINE EASEMENT GRANTED TO CITY OF ASPEN BK.291 PG.649 BUILDING FOOTPRINT AT GROUND LEVEL MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT (SEE DEDICATION PARAGRAPH 5 AND 12) TEMPORARY RECIPROCAL CONSTRUCTION EASEMENT (SEE DEDICATION PARAGRAPH 3)SUBSURFACE STRUCTURAL EASEMENT (SEE DEDICATION PARAGRAPH 4) TEMPORARY RECIPROCAL CONSTRUCTION EASEMENT (SEE DEDICATION PARAGRAPH 3) LOT 1 SKI ACCESS FROM NORWAY SKI RUN SOUT H A S P E N S T R E E T R O W UTILITY EASEMENT (SEE DEDICATION PARAGRAPH 8)LOT 2 LOT 2 SHADOW MOUNTAIN VILLAGE CONDOMINIUMS LIFT ONE LODGE SUBDIVISION LIFT TOWER 4 HI L L S T R E E T R O W LOT 3 SUBSURFACE EASEMENT (ALL OF LOT 3) REC. #597440 LOT 1 RECREATION EASEMENT REC. #597440 NO BUILD AND MAINTENANCE EASEMENT REC. #597440 LIFT FACILITIES EASEMENT (SEE DEDICATION PARAGRAPH 9) MOUNTAIN OPERATION ROAD PRIVATE ACCESS EASEMENT (SEE DEDICATION PARAGRAPH 10) S7 5 ° 0 9 ' 1 1 " E RE C R E A T I O N A L U S E E A S E M E N T GR A N T E D T O A S P E N S K I I N G C O M P A N Y L L C BY T H E C I T Y O F A S P E N RE C . # _ _ _ _ _ _ _ _ _ _ _ 50' SETBACK BUILDING RESTRICTION BK 231 PG 278 PUBLIC PEDESTRIAN EASEMENT TO S. ASPEN STREET UTILITY EASEMENT (SEE DEDICATION PARAGRAPH 8) PUBLIC PEDESTRIAN EASEMENT TO S. ASPEN STREET AND BARBEE OPEN SPACE BARBEE OPEN SPACE SKIWAY 19.7' LIFT CENTERL I N E LIFT TOWER 5 LIFT TOWER 6 5.0' SETBACK (TYP) 5.0' SETBACK (TYP) 5.0' SETBACK (TYP) UTILITY EASEMENT (SEE DEDICATION PARAGRAPH 8) 5' PUBLIC TRAIL EASEMENT (SEE DEDICATION PARAGRAPH 2) SKIWAY LOT 2 FINAL PLAT OF: SHEET 4 OF 4 SUBDIVISION EASEMENTS GORSUCH HAUS PD/SUBDIVISION A PARCEL OF LAND SITUATED IN THE NE1 4 OF SECTION 13, TOWNSHIP 10 SOUTH, RANGE 85 WEST OF THE 6th P.M., CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO THE PURPOSE OF THIS PLAT IS TO CREATE A PLANNED DEVELOPMENT (PD), REZONE, AND SUBDIVIDE THE SUBJECT PROPERTY NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. SOPRIS ENGINEERING - LLC CIVIL CONSULTANTS 502 MAIN STREET, SUITE A3 CARBONDALE, COLORADO 81623 (970) 704-0311 CL sb 13139.01 02/26/2020 G:\2013\13139\SURVEY\Survey DWGs\Survey Plots\13139-SUBDIVISION.dwg 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 20 8010 HATCH LEGEND ASPEN STREET AND HILL STREET RIGHT-OF-WAY PER THIS PLAT AREA OF REVOCABLE ENCROACHMENT LICENSE (REC. #543674) STAIRS PUBLIC TRAIL EASEMENT (SEE DEDICATION PARAGRAPH 2) MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT FOR THE BENEFIT OF LOT 1 (SEE DEDICATION PARAGRAPH 5) RECREATIONAL USE EASEMENT FOR THE BENEFIT OF ASPEN SKI COMPANY (DEDICATED BY THE CITY OF ASPEN) PUBLIC PEDESTRIAN EASEMENT (SEE DEDICATION PARAGRAPH 6) UTILITY EASEMENT (SEE DEDICATION PARAGRAPH 8) RESERVED LIFT AND SKI FACILITY EASEMENT AREA (SEE DEDICATION PARAGRAPH 9) MOUNTAIN OPERATIONS ROAD PRIVATE ACCESS EASEMENT FOR THE BENEFIT OF ASPEN SKI COMPANY (SEE DEDICATION PARAGRAPH 10) MOUNTAIN OPERATIONS ROAD PRIVATE EASEMENT FOR PEDESTRIAN AND BICYCLE USES (SEE DEDICATION PARAGRAPH 12) AREA SUBJECT TO PARAGRAPH 4 "TEMPOPARY CONTRUCTION EASEMENTS AND PERMANENT ENCROACHMENT EASEMENTS" PER THE MASTER EASEMENT AGREEMENT RECORDED AS REC. #597440 20.0' HILL ST R E E T SUMM I T S T R E E T LOT 1 LIFT ONE LODGE SUBDVISION/PUD REC. #597438 S. ASPEN STREET ROW 75.30' WIDE 37.65' 37.65' SHADOW MOUNTAIN VILLAGE CONDOMINIUMS PLAT BK. 3 PG. 33 LOT 2 SOUTH ASPEN STREET SUBDIVISION/PUD, 1ST AMENDED REC. #616166 (A/K/A ONE ASPEN) CONSERVATION PARCEL BARBEE FAMILY SUBDIVISION, FIRST AMENDED REC. #461107 CITY OF ASPEN MOUNTAIN QUEEN CONDOMINIUMS PLAT BK. 4 PG. 489 CARIBOU CONDOMINIUMS PLAT BK. 94 PG. 52 GOVERNMENT LOT 31 SECTION 13, T10S, R85W ASPEN SKIING COMPANY LOT 3 LIFT ONE LODGE SUBDVISION/PUD REC. #597438 S. A S P E N S T R E E T NE14 NE14 SECTION 13 SE14 NE14 SECTION 13 63.71' 90.50' 28.56' 26.13' 90.50' 65.81' 88 . 0 3 ' LO T 1 4 LO T 1 3 LO T 1 2 LO T 1 1 LO T 1 0 LO T 9 LO T 6 LO T 5 LO T 4 LO T 3 LO T 2 LO T 1 LO T 8 LO T 1 LO T 2 LO T 3 LO T 4 LO T 5 LO T 7 LO T 6 BLOCK 12 EAMES ADD. BLOCK 10 EAMES ADD. PARCEL C VACATED TO BLOCK 10 EAMES ADDITION ASPEN SKIING COMPANY LLC 1,827 SQ.FT. PARCEL D VACATED TO BLOCK 12 EAMES ADDITION ASPEN SKIING COMPANY LLC 1,825 SQ.FT. PARCEL A VACATED TO BLOCK 10 EAMES ADDITION ASPEN SKIING COMPANY LLC 1917 SQ.FT.± PARCEL B VACATED TO BLOCK 12 EAMES ADDITION ASPEN SKIING COMPANY LLC 2,592 SQ.FT. GOVERNMENT LOT 1 SECTION 13, T10S, R85W ASPEN SKIING COMPANY S1 5 ° 4 6 ' 5 8 " W 1 3 0 . 0 2 ' S1 4 ° 5 0 ' 4 9 " W 1 3 0 . 0 0 ' S75° 0 9 ' 1 1 " E 1 8 1 . 4 6 ' PEDESTRIAN ACCESS EASEMENT FOUND #5 REBAR AND 114" PLASTIC CAP L.S. #25947 FOUND 4' WITNESS CORNER #5 REBAR AND 1.25" PLASTIC CAP L.S. #29030 (B A S I S O F B E A R I N G ) N 1 4 ° 5 0 ' 4 9 " E ( T I E ) N 1 3 ° 3 4 ' 5 1 " W 8 3 0 . 7 8 ' ( T I E ) N 0 4 ° 5 6 ' 3 9 " W 1 7 1 0 . 5 8 ' FOUND 3.5" ALUM. CAP 2009 MARCIN GPS CONTROL GPS-3 @ GARMISCH AND DURANT FOUND 3.5" ALUM. CAP 2009 MARCIN GPS CONTROL GPS-6 @ GARMISCH AND HOPKINS S1 4 ° 5 0 ' 4 9 " W 6 0 . 0 0 ' S1 5 ° 4 6 ' 5 8 " W 6 0 . 0 1 ' LOT 7 15' WIDE WATERLINE EASEMENT BK. 412 PG. 557 TERMINATED BY THIS PLAT (SEE PLAT NOTE 2(e)) 131.62 ' 53.27' ORIGINAL CENTERLINE S. ASPEN STREET CENTERLINE SUMMIT STREET S75° 0 9 ' 1 1 " E 3 7 . 6 5 ' N1 4 ° 5 0 ' 4 9 " E 5 1 . 9 7 ' N78° 21' 5 8 " W 3 7 . 7 1 ' S1 4 ° 5 0 ' 4 9 " W 4 9 . 8 6 ' S1 4 ° 5 0 ' 4 9 " W 7 3 . 8 7 ' N89° 55' 06"E 38.97' N1 4 ° 5 0 ' 4 9 " E 6 3 . 8 3 ' N75° 0 9 ' 1 1 " W 3 7 . 6 5 ' S75° 0 9 ' 1 1 " E 1 8 2 . 4 4 ' S75° 0 9 ' 1 1 " E 1 8 2 . 6 0 ' N75° 0 9 ' 1 1 " W 1 8 2 . 7 6 ' 10 . 0 0 10 . 0 0 10 . 0 0 10 . 0 0 CENTERLINE 90' SKI EASEMENT VACATED BY THIS PLAT (SEE PLAT NOTE 2(c)) AREA OF ENCROACHMENT LICENSE REVOKED BY THIS VACATION PLAT (PORTION OF REC. #543674 LYING EASTERLY OF CENTERLINE SOUTH ASPEN STREET ROW) SHEET 1 OF 1 STREET AND EASEMENT VACATION PLAT SUMMIT STREET AND PORTIONS OF SOUTH ASPEN STREET CITY OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED UPON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT MAY ANY ACTION BASED UPON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. SOPRIS ENGINEERING - LLC CIVIL CONSULTANTS 502 MAIN STREET, SUITE A3 CARBONDALE, COLORADO 81623 (970) 704-0311 SOPRISENG@SOPRISENG.COM CL 13139.01 02/26/2020 G:\2013\13139\SURVEY\Survey DWGs\Survey Plots\13139-VACATION.dwg 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 020 20 40 20 8010 NOTES 1)DATE OF FIELD WORK: AUGUST - SEPTEMBER 2005; UPDATED MAY 2006, JUNE AND JULY 2007, OCTOBER - DECEMBER 2008, SEPTEMBER 2009, AND MARCH 2010; UPDATED AUGUST 2013; UPDATED SEPTEMBER 2015; UPDATED MAY 2018 2)DATE OF PREPARATION: FEBRUARY - MARCH 2016; UPDATED AUGUST - SEPTEMBER 2016; UPDATED MAY - JUNE 2018; UPDATED JANUARY AND FEBRUARY 2020 3)BASIS OF BEARING: A BEARING OF N 14°50'49" E BETWEEN THE SOUTHEAST CORNER OF SHADOW MOUNTAIN VILLAGE, A FOUND REBAR AND CAP L.S. #25947, AND THE 4' WITNESS CORNER TO THE SOUTHEAST CORNER OF SOUTH ASPEN STREET SUBDIVISION, A FOUND REBAR & CAP LS #29030. 4)BASIS OF SURVEY: THE 1896 W. C. WILLITS MAP OF ASPEN, COLORADO, THE OFFICIAL MAP OF THE CITY OF ASPEN PREPARED BY G.E. BUCHANAN DATED DECEMBER 15, 1959, CITY OF ASPEN GPS CONTROL MONUMENTATION MAP PREPARED BY MARCIN ENGINEERING LLC, DATED DECEMBER 2, 2009, THE PLAT OF LIFT ONE LODGE SUBDIVISION, RECORDED MARCH 5, 2013, THE STREET, ALLEYWAY AND EASEMENT VACATION PLAT RECORDED MARCH 5, 2013 UNDER RECEPTION NO. 597435, THE PLAT OF SOUTH ASPEN STREET SUBDIVISION RECORDED APRIL 27, 2007, THE CONDOMINIUM MAP OF MOUNTAIN QUEEN CONDOMINIUMS RECORDED SEPTEMBER 27, 1974, THE CONDOMINIUM MAP OF CARIBOU CONDOMINIUMS RECORDED SEPTEMBER 8, 2009, THE CONDOMINIUM MAP OF SHADOW MOUNTAIN VILLAGE, THE AMENDED PLAT OF BARBEE FAMILY SUBDIVISION/PUD RECORDED NOVEMBER 21, 2001, DOCUMENTS OF RECORD AND THE FOUND LOT AND BLOCK CORNER SURVEY MONUMENTS, AS SHOWN. 5)THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH BY SOPRIS ENGINEERING, LLC (SE) TO DETERMINE OWNERSHIP OR EASEMENTS OF RECORD. FOR ALL INFORMATION REGARDING EASEMENTS, RIGHTS OF WAY AND/OR TITLE OF RECORD, SE RELIED UPON THE ABOVE SAID ITEMS DESCRIBED IN NOTE 4 AND THE TITLE COMMITMENT PREPARED BY PITKIN COUNTY TITLE, INC. UNDER CASE NO. PCT23785W13 DATED MARCH 4, 2016. 6)THE LINEAR UNIT USED IN THE PREPARATION OF THIS PLAT IS THE U.S. SURVEY FOOT AS DEFINED BY THE UNITED STATES DEPARTMENT OF COMMERCE, NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY. 7)ALL REFERENCES TO BOOK AND PAGE AND RECEPTION NUMBERS ARE THOSE RECORDED IN THE PITKIN COUNTY CLERK AND RECORDERS OFFICE. CITY ENGINEER'S APPROVAL THIS STREET AND EASEMENT VACATION PLAT WAS REVIEWED BY THE CITY ENGINEER OF THE CITY OF ASPEN THIS __________ DAY OF _____________, 2020. ____________________________ CITY ENGINEER CLERK AND RECORDER'S ACCEPTANCE THIS STREET AND EASEMENT VACATION PLAT IS ACCEPTED FOR FILING IN THE OFFICE OF THE CLERK AND RECORDER OF PITKIN COUNTY, COLORADO AT _________ O'CLOCK ____.M., THIS _______ DAY OF ________________, 2020, IN PLAT BOOK ______, AT PAGES ___________, RECEPTION NUMBER ______________. ________________________________________ PITKIN COUNTY CLERK AND RECORDER STREET AND EASEMENT VACATION PLAT CERTIFICATE I, MARK S. BECKLER, A REGISTERED PROFESSIONAL LAND SURVEYOR, DO HEREBY CERTIFY THAT I HAVE PREPARED THIS STREET AND EASEMENT VACATION PLAT, AS LAID OUT, PLATTED, DEDICATED AND SHOWN HEREON, THAT THE SAME IS BASED ON FIELD SURVEYS PERFORMED UNDER MY SUPERVISION; THAT THIS MEETS THE REQUIREMENTS OF A LAND SURVEY PLAT AS SET FORTH IN CRS SECTION 38-51-106; THE CONTROL PRECISION IS GREATER THAN 1 IN 15,000. _______________________________ MARK S. BECKLER, PROFESSIONAL LAND SURVEYOR COLORADO LICENSE # 28643 CITY OF ASPEN APPROVAL THE UNDERSIGNED CERTIFIES THAT THIS STREET AND EASEMENT VACATION PLAT SATISFIES THE REQUIREMENTS OF SECTION ____ OF ORDINANCE NO. ___, SERIES OF 2020, AND UPON RECORDING SHALL COMPLETE THE PROCESS OF VACATING THE STREETS AND EASEMENTS WHICH ARE DESCRIBED ON THIS PLAT. THE ENCROACHMENT LICENSE RECORDED AT RECEPTION NO. 543674 EFFECTING THOSE AREAS WITHIN THE VACATED SOUTH ASPEN STREET RIGHT OF WAY IS HEREBY REVOKED, AS SHOWN HEREON. CITY OF ASPEN BY:______________________________________ TORRE AS:MAYOR OF THE CITY OF ASPEN ATTEST:____________________________________ NAME AS:CITY CLERK HATCH LEGEND ROW TO BE VACATED TO PRIVATE PARCELS 90' WIDE SKI EASEMENT (BK. 259 PG. 83) ANY CITY RIGHTS ARE EXTINGUISHED PER THIS PLAT AND TERMINATED BY ASPEN SKIING COMPANY PER THIS PLAT AREA OF REVOCABLE ENCROACHMENT LICENSE AGREEMENT BETWEEN CITY OF ASPEN AND SHADOW MOUNTAIN VILLAGE CONDOMINIUMS REC. #543674 15' WIDE WATER PIPELINE EASEMENT (BK. 412 PG. 557) GRANTED BY ASPEN SKIING COMPANY TO THE CITY OF ASPEN, TERMINATED BY THIS PLAT SUBJECT TO PLAT NOTE 2(e) AREA OF ENCROACHMENT LICENSE REVOKED BY THIS VACATION PLAT (PORTION OF REC. #543674 LYING EASTERLY OF CENTERLINE SOUTH ASPEN STREET ROW) SITE PLAT NOTES 1)THE OWNERSHIP AND TITLE TO THE VACATED STREETS SHALL BE DISTRIBUTED PURSUANT TO SECTION 43-2-302 (d) OF THE COLORADO REVISED STATUTES AND IS REPRESENTED ON THIS PLAT. 2)THE PURPOSE OF THIS PLAT IS TO DESCRIBE THE PUBLIC RIGHTS-OF-WAY, STREETS AND EASEMENTS, WHICH WERE VACATED BY THE PROVISIONS OF ORDINANCE 39, SERIES OF 2016; AND BY THE RECORDING OF THIS PLAT: a)VACATION OF THE EASTERLY HALF (37.65 FEET) OF SOUTH ASPEN STREET FROM A POINT 88.03 FEET SOUTH OF THE SOUTHERLY RIGHT-OF-WAY LINE OF HILL STREET EXTENDING SOUTH TO THE SOUTH LINE OF NE1 4NE1 4 OF SECTION 13. b)VACATION OF SUMMIT STREET BETWEEN BLOCKS 10 AND 12 OF THE EAMES ADDITION. c)TERMINATION OF A 90' WIDE SKI EASEMENT LOCATED IN SUMMIT STREET BETWEEN BLOCKS 10 AND 12, EAMES ADDITION. d)TERMINATION AND MEMORIALIZATION OF THE DOCTRINE OF MERGER OF THE SKIING USE/RIGHTS GRANTED BY THAT AGREEMENT RECORDED IN BK. 175 PG. 40 AND THAT DEED RECORDED IN BK. 170 PG. 555. e)TERMINATION OF THAT 15' WIDE UNDERGROUND WATER PIPELINE PER THAT DOCUMENT RECORDED IN BK. 412 PG. 557; SAID TERMINATION WILL BE DEEMED EFFECTIVE UPON THE CONSTRUCTION OF A NEW REPLACEMENT WATER MAIN AND THE GRANTING OF A CERTIFICATE OF OCCUPANCY FOR IMPROVEMENTS ON LOT 1 OF THE GORSUCH HAUS PD/SUBDIVISION. 3) THAT REVOCABLE ENCROACHMENT LICENSE DESCRIBED AS REC. #543674 IS HEREBY AMENDED TO EXCLUDE PORTION LYING EASTERLY OF THE CENTERLINE OF THE SOUTH ASPEN STREET ROW, PER THIS VACATION PLAT. CERTIFICATE AND CONSENT OF ASPEN SKIING COMPANY THE UNDERSIGNED CERTIFIES THAT THEY ARE THE BENEFICIARIES OF THOSE EASEMENTS GRANTED IN BOOK 259 AT PAGE 83, BOOK 175 AT PAGE 40, AND BOOK 170 AT PAGE 555, AND CONSENTS TO THE VACATION OF THE STREETS AND EASEMENTS AS SHOWN HEREON. EXECUTED THIS____ DAY OF ________________ , A.D., 2020. ASPEN SKIING COMPANY, LLC, A COLORADO LIMITED LIABILITY COMPANY BY: ____________________________________________________________ _____________________, ITS MANAGER STATE OF COLORADO ) )SS. COUNTY OF PITKIN ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS ______ DAY OF ____________, 2020, BY _____________________ AS MANAGER OF ASPEN SKIING COMPANY, LLC. WITNESS MY HAND AND OFFICIAL SEAL MY COMMISSION EXPIRES _________ __________________________________________________ NOTARY PUBLIC ADDRESS VICINITY MAP SCALE: 1" = 2000'