HomeMy WebLinkAboutSupplemental_Gorsuch Haus Outdoor Lighting Plan (1)5T
D
ST1 ST1 ST1 ST1
M2
M3
M3 M3
M3M3
M3
M2
M2
M2
ST1 ST1 ST1
Z1
Z1 Z1 Z1
A1 A1 A1
A1A1A1
Z1
Z1Z1Z1
Z1
ST1
ST1
ST1
WALL SCONCE, FULL
SHIELD UP/DOWN
STEPLIGHT, EVERY THIRD
STEP FROM TOP OF RUN
IN GROUND UPLIGHT
DOWNLIGHT
RECESSED IN SOFFIT
RECESSED WALL LIGHT
STREET LIGHT
FLAGPOLE LIGHTING
LANDSCAPE ACCENT
LIGHTING MONUMENT
RECESSED WALL
LIGHTS
Z1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
E1
E1
E1
E6
E6
E6
E6
E6
E6
ST1
ST1
ST1
SHIELDED FIXED DOWNLIGHT SCONCE
STEPLIGHTS CONTINUE UP STEPS HERE
M2M3
M2
W
W
E3
E3E3
E3
E3
E3
UNDERWATER MONOPOINTS
IN WATER FEATURE. EXACT
LOCATION TBD
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-101
LEVEL 1 LIGHTING PLAN
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURAL
ENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEP
ENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICAL
ENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTING
DESIGNER
1/8" = 1'-0"1 LEVEL 1 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
LEVEL 1 LIGHTING PLAN SCALE: 1/16”=1”LEVEL 2 LIGHTING PLAN SCALE: 1/16”=1”
5T
D
ST1 ST1 ST1 ST1
M2
M3
M3 M3
M3M3
M3
M2
M2
M2
ST1 ST1 ST1
Z1
Z1 Z1 Z1
A1 A1 A1
A1A1A1
Z1
Z1Z1Z1
Z1
ST1
ST1
ST1
WALL SCONCE, FULL
SHIELD UP/DOWN
STEPLIGHT, EVERY THIRD
STEP FROM TOP OF RUN
IN GROUND UPLIGHT
DOWNLIGHT
RECESSED IN SOFFIT
RECESSED WALL LIGHT
STREET LIGHT
FLAGPOLE LIGHTING
LANDSCAPE ACCENT
LIGHTING MONUMENT
RECESSED WALL
LIGHTS
Z1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
E1
E1
E1
E6
E6
E6
E6
E6
E6
ST1
ST1
ST1
SHIELDED FIXED DOWNLIGHT SCONCE
STEPLIGHTS CONTINUE UP STEPS HERE
M2M3
M2
W
W
E3
E3E3
E3
E3
E3
UNDERWATER MONOPOINTS
IN WATER FEATURE. EXACT
LOCATION TBD
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-101
LEVEL 1 LIGHTING PLAN
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREETDENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 LEVEL 1 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
5T
72
24
5T60
24
5T 52
24
5T60
24
5T 48
24
5T 48
24
5T48
24
5T48
245T
48
24
5T72
18
5T72
18
5T72
18
5T72
18
5T
36
24
5T48
24
5T36
24
5T
72
24
5T36
14
5T30
14
JAN.
BEV/SERVER ICE
COOKEXPO
SERVICE
ADA
SERVICE
HOST
HOST
SERV.
FIREPLACE
PANTRY
SH
E
L
F
SH
E
L
F
SH
E
L
F
SHELF
UNIVERSAL MOP 20-8
H CFISHER2445
D
C
D
DC
DBL RACK
CH
E
M
D H
H
C
H
C
14
5T72
14
5T72
FIXED MONOPOINT @ 6" ABOVE
DECK, UPLIGHTING KNEE
BRACE THAT HAS BEEN
INTERRUPTED BY DECK
M2
M2
ST1
ST1
ST1 ST1 ST1 ST1 ST1 ST1 ST1
M3 M3
WALL SCONCE, FULL SHIELD, UP/DOWN
STEP LIGHT, EVERY THIRD STEP FROM TOP
MINI DOWNLIGHTS UNDER BAR COUNTER
MONOPOINT ON BUILDING SIDE
OF TIMBER COLUMN,
POINTING DOWN. MOUNTED TO
BLOCKING BETWEEN COLUMNS
WDECORATIVE SCONCE
WALL SCONCE, FULL
SHIELD - DOWN ONLY
A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2
RECESSED WALL LIGHT
DOWNLIGHTS
A1
A1
A1 A1
A1
A1
W
M2
M2
M2
M2
M2
M2M2
M2
SIDE KNEE BRACES ARE
CONTINUOUS, AND
ILLUMINATED LEVEL BELOW
SHOWN ABOVE: FIXED DOWNLIGHT MONOPOINTS
LIGHTING DOWNDOUBLE WOOD COLUMN,
MOUNTED TO BLOCKING IN-BETWEEN STRUCTURE
M3
ST1 ST1 ST1ST1 ST1 ST1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-103
LEVEL 3 LIGHTING PLAN
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREETDENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 LEVEL 3 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
5T72
24
5T72
24
5T
60
24
5T
60
24
5T
60
24
5T
60
24
5T 36
24
5T66
24
5T
72
24
5T
72
24
BEV/SERVICE
DISH
ASSEMBLY
PLATING STOR.
HOTHOLDING
REF.
REF.
FR.FR.
STORAGE
ICE
D
C
WIN
S
T
O
N
C
A
C
-
5
2
2
D
C
WIN
S
T
O
N
C
A
C
-
5
2
2
D
C
WIN
S
T
O
N
C
A
C
-
5
2
2
DBL RACK
TRU
E
T
-
4
9
F
TRU
E
T
-
4
9
F
TRUE T-49F TRUE T-49F
UNIVERSAL MOP 20-8
FISHER2445
1331NEW AGE
1331NEW AGE
1331NEW AGE
AIR
IN
D
D
C AIROU
T
HO
S
H
I
Z
A
K
I
K
M
-
1
3
0
1
S
A
H
3
D
1331NEW AGE
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
MONOPOINT
MOUNTED UNDER
EAVE, POINTING
DOWN
STEPLIGHT, EVERY THIRD STEP FROM TOP OF RUN
ST1
ST1
ST1
ST1
ST1
RECESSED WALL LIGHT
M2
M2
M2
M2
SHIELDED SCONCE
LIGHTS UP FROM BASE
OF ANGLED BEAM
STEPLIGHTS CONTINUE DOWN STEPS HERE
ST1 ST1 ST1 ST1 ST1 ST1
M1
M1
M1
M1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :DESIGNER:DRAFTER:CHECKER:APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-102
LEVEL 2 LIGHTING PLAN
21222.00DesignerAuthorCheckerApprover
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUEAURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 LEVEL 2 LIGHITNG PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
POST TOP LANTERN
FIXED DOWNLIGHT MONOPOINTS LIGHTING
DOWNDOUBLE WOOD COLUMN, MOUNTED TO
BLOCKING IN-BETWEEN STRUCTURE
WW
ST1 ST1 ST1 ST1
ST1 ST1 ST1 ST1
ST1ST1ST1ST1
ST1
ST1
ST1
ST1
WALL SCONCE, FULL
SHIELD UP/DOWN
WALL SCONCE, FULL
SHIELD - DOWN ONLY
RECESSED WALL LIGHTS
E4 E4
E4
M2M2M2
M3M3M3
M3 M3 M3
ST1 ST1
ST1
FOUR MONOPOINTS TO
LIGHT WATER FEATURE
BELOW. LOCATION TBC
ON-SITE
M1 M1
M1 M1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-104
LEVEL 4 LIGHTING PLAN
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREETDENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 LEVEL 4 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
LEVEL 3 LIGHTING PLAN SCALE: 1/16”=1”LEVEL 4 LIGHTING PLAN SCALE: 1/16”=1”
5T72
24
5T72
24
5T
60
24
5T
60
24
5T
60
24
5T
60
24
5T 36
24
5T66
24
5T
72
24
5T
72
24
BEV/SERVICE
DISH
ASSEMBLY
PLATING STOR.
HOT
HOLDING
REF.
REF.
FR.FR.
STORAGE
ICE
D
C
WIN
S
T
O
N
C
A
C
-
5
2
2
D
C
WIN
S
T
O
N
C
A
C
-
5
2
2
D
C
WI
N
S
T
O
N
C
A
C
-
5
2
2
DBL RACK
TR
U
E
T
-
4
9
F
TR
U
E
T
-
4
9
F
TRUE T-49F TRUE T-49F
UNIVERSAL MOP 20-8
FISHER2445
1331
NEW AGE
1331
NEW AGE
1331
NEW AGE
AI
R
IN
D
D
C AI
R
OU
T
HO
S
H
I
Z
A
K
I
K
M
-
1
3
0
1
S
A
H
3
D
1331
NEW AGE
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
MONOPOINT
MOUNTED UNDER
EAVE, POINTING
DOWN
STEPLIGHT, EVERY THIRD STEP FROM TOP OF RUN
ST1
ST1
ST1
ST1
ST1
RECESSED WALL LIGHT
M2
M2
M2
M2
SHIELDED SCONCE
LIGHTS UP FROM BASE
OF ANGLED BEAM
STEPLIGHTS CONTINUE DOWN STEPS HERE
ST1 ST1 ST1 ST1 ST1 ST1
M1
M1
M1
M1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-102
LEVEL 2 LIGHTING PLAN
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURAL
ENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEP
ENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICAL
ENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTING
DESIGNER
1/8" = 1'-0"1 LEVEL 2 LIGHITNG PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
FP
FP
DOWNLIGHTS IN SOFFIT
OUTLETS FOR HOLIDAY LIGHTING
SP
A
L
I
G
H
T
S
B
Y
SP
A
D
E
S
I
G
N
E
R
LIGHT IN TOEKICK
OF FIREPLACE
ST1
ST1
ST1 ST1
ST1
ST1
A1
A1
A1
A1
A1
A1
A1
A1
L1
ST1
ST1
ST1
ST1ST1ST1
ST1
ST1
ST1 ST1 ST1 ST1
ST1ST1ST1
RECESSED WALL LIGHT
ST1 ST1
ST1
ST1
ST1
STRING LIGHTS
MOUNTED TO POLE /
ROOF FASCIA
E5
E5
E2
E2
M2M2
FIXED DOWNLIGHT MONOPOINTS LIGHTING DOWN
DOUBLE WOOD COLUMN, MOUNTED TO BLOCKING
IN-BETWEEN STRUCTURE
M2 M2
ST1
ST1M2
M2
LI
G
H
T
I
N
G
D
E
S
I
G
N
H
E
R
E
T
B
D
E2
E2
25X50 EVENT TENT
FLOOR OUTLETS FOR EVENTS, VERIFY
QTY AND LOCATION WITH ARCHITECT.
FLOOR OUTLETS FOR EVENTS, VERIFY
QTY AND LOCATION WITH ARCHITECT.
UNDERWATER MONOPOINTS
IN WATER FEATURE BASIN
E3
E3
E3
E3
E3
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-108
LEVEL 8 LIGHTING PLAN
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURAL
ENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEP
ENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICAL
ENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTING
DESIGNER
1/8" = 1'-0"1 LEVEL 8 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
ST1
ST1
ST1 ST1ST1 ST1ST1
ST1
ST1ST1ST1
ST1
ST1ST1
ST1
ST1 ST1 ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
A1 A1 A1 A1 A1 A1
A1
A1
A1
A1
DOWNLIGHT
RECESSED IN SOFFIT
MONOPOINTS LIGHTING BEAM DOWN
MONOPOINTS LIGHTING UP
COLUMN FROM BASE,
MOUNTED TO BLOCKING
BETWEEN STRCTURE
RECESSED WALL LIGHT
ST1
M2 M2 M2
FIXED DOWNLIGHT MONOPOINTS LIGHTING
DOWNDOUBLE WOOD COLUMN, MOUNTED TO
BLOCKING IN-BETWEEN STRUCTURE
M2
M2
M2
M2
M2
M2 M2 M2
M2 M2 M2
ST1
ST1ST1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :DESIGNER:DRAFTER:CHECKER:APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-105
LEVEL 5 LIGHTING PLAN
21222.00DesignerAuthorCheckerApprover
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLCASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300LAKEWOOD, CO 80401
MEP
ENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUEAURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP1200 BANNOCK STREET
DENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 LEVEL 5 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
ST1ST1 ST1ST1
ST1ST1 ST1ST1
ST1 ST1
ST1
ST1ST1 ST1ST1
ST1
ST1 ST1 ST1 ST1 ST1 ST1 ST1
ST1 ST1 ST1 ST1
ST1 ST1ST1
ST1
ST1
ST1
ST1
M3 M3 M3
M3 M3 M3
WALL SCONCE, FULL
SHIELD UP/DOWN
RECESSED
WALL LIGHT
M2 M2 M2
FIXED DOWNLIGHT MONOPOINTS LIGHTING DOWN
DOUBLE WOOD COLUMN, MOUNTED TO BLOCKING
IN-BETWEEN STRUCTURE
MONOPOINTS UNDER DECK LIGHTING DOWN WOOD
DOUBLE COLUMN FOR CONTINUOUS APPEARANCE FROM
ABOVE. MOUNTED TO BLOCKING BETWEEN STRUCTURE.
M2 M2 M2
M2
M2
M2
MONOPOINTS LIGHTING UP
COLUMN FROM BASE,
MOUNTED TO BLOCKING
BETWEEN STRCTURE
M2 M2
M2M2 M2
M2
ST1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-107
LEVEL 7 LIGHTING PLAN
21222.00
Designer
Author
CheckerApprover
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUEAURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREETDENVER CO 80204
LIGHTING
DESIGNER
1/8" = 1'-0"1 LEVEL 7 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
ST1ST1 ST1ST1 ST1
ST1
ST1 ST1ST1ST1ST1
ST1
ST1 ST1
ST1 ST1 ST1 ST1
ST1 ST1 ST1 ST1 ST1
M3 M3 M3
M3 M3 M3
MONOPOINTS LIGHTING BEAM DOWN
WALL SCONCE, FULL SHIELD UP/DOWN
RECESSED WALL LIGHT
ST1
STEPLIGHTS CONTINUE DOWN STEPS HERE
ST1
M2
M2 M2
M2
M2
M2M2
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :DESIGNER:DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-106
LEVEL 6 LIGHTING PLAN
21222.00DesignerAuthor
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREETDENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 LEVEL 6 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
FP
FP
DOWNLIGHTS IN SOFFIT
OUTLETS FOR HOLIDAY LIGHTING
SP
A
L
I
G
H
T
S
B
Y
SP
A
D
E
S
I
G
N
E
R
LIGHT IN TOEKICK
OF FIREPLACE
ST1
ST1
ST1 ST1
ST1
ST1
A1
A1
A1
A1
A1
A1
A1
A1
L1
ST1
ST1
ST1
ST1ST1ST1
ST1
ST1
ST1 ST1 ST1 ST1
ST1ST1ST1
RECESSED WALL LIGHT
ST1 ST1
ST1
ST1
ST1
STRING LIGHTS
MOUNTED TO POLE /
ROOF FASCIA
E5
E5
E2
E2
M2M2
FIXED DOWNLIGHT MONOPOINTS LIGHTING DOWN
DOUBLE WOOD COLUMN, MOUNTED TO BLOCKING
IN-BETWEEN STRUCTURE
M2 M2
ST1
ST1M2
M2
LI
G
H
T
I
N
G
D
E
S
I
G
N
H
E
R
E
T
B
D
E2
E2
25X50 EVENT TENT
FLOOR OUTLETS FOR EVENTS, VERIFY
QTY AND LOCATION WITH ARCHITECT.
FLOOR OUTLETS FOR EVENTS, VERIFY
QTY AND LOCATION WITH ARCHITECT.
UNDERWATER MONOPOINTS
IN WATER FEATURE BASIN
E3
E3
E3
E3
E3
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :DESIGNER:DRAFTER:CHECKER:APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-108
LEVEL 8 LIGHTING PLAN
21222.00DesignerAuthorCheckerApprover
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 LEVEL 8 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
ST1
ST1
ST1
ST1
FIXED DOWNLIGHT MONOPOINTS LIGHTING
DOWN DOUBLE WOOD COLUMN, MOUNTED
TO BLOCKING IN-BETWEEN STRUCTURE
M2
M2
M2
M2
M2
M2
M2 M2
M2 M2 M2
M2
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-109
LEVEL 9 LIGHTING PLAN
21222.00
Designer
Author
CheckerApprover
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUEAURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREETDENVER CO 80204
LIGHTING
DESIGNER
1/8" = 1'-0"1 LEVEL 9 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
LEVEL 5 LIGHTING PLAN SCALE: 1/16”=1”LEVEL 6 LIGHTING PLAN SCALE: 1/16”=1”
LEVEL 7 LIGHTING PLAN SCALE: 1/16”=1”LEVEL 8 LIGHTING PLAN SCALE: 1/16”=1”ROOF LIGHTING PLAN SCALE: 1/16”=1”
M2
M2
M2
M2M2M2
M2
M2
M2 M2
M3M3
M2
M3M2M2
M2 M2 M2
M2 M2 M2 M2 M2
M2 M2
M3
M2 M2M2
M3
A1 A1
Z1Z1Z1Z1Z1Z1
E4E4
W
M2
A1
M2
A2
ST1 ST1 ST1 ST1
A1A1A1
ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1
ST1 ST1 ST1
M3
ST1ST1ST1ST1ST1ST1ST1ST1ST1ST1ST1ST1
M2
ST1 ST1
M1 M1 M1 M1
M1
M1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-201
NORTH ELEVATION
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURAL
ENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEP
ENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICAL
ENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTING
DESIGNER
1/8" = 1'-0"1 NORTH - LIGHTING
25% DESIGN
DEVELOPMENT
15 JAN 2020
FP
FP
DOWNLIGHTS IN SOFFIT
OUTLETS FOR HOLIDAY LIGHTING
SP
A
L
I
G
H
T
S
B
Y
SP
A
D
E
S
I
G
N
E
R
LIGHT IN TOEKICK
OF FIREPLACE
ST1
ST1
ST1 ST1
ST1
ST1
A1
A1
A1
A1
A1
A1
A1
A1
L1
ST1
ST1
ST1
ST1ST1ST1
ST1
ST1
ST1 ST1 ST1 ST1
ST1ST1ST1
RECESSED WALL LIGHT
ST1 ST1
ST1
ST1
ST1
STRING LIGHTS
MOUNTED TO POLE /
ROOF FASCIA
E5
E5
E2
E2
M2M2
FIXED DOWNLIGHT MONOPOINTS LIGHTING DOWN
DOUBLE WOOD COLUMN, MOUNTED TO BLOCKING
IN-BETWEEN STRUCTURE
M2 M2
ST1
ST1M2
M2
LI
G
H
T
I
N
G
D
E
S
I
G
N
H
E
R
E
T
B
D
E2
E2
25X50 EVENT TENT
FLOOR OUTLETS FOR EVENTS, VERIFY
QTY AND LOCATION WITH ARCHITECT.
FLOOR OUTLETS FOR EVENTS, VERIFY
QTY AND LOCATION WITH ARCHITECT.
UNDERWATER MONOPOINTS
IN WATER FEATURE BASIN
E3
E3
E3
E3
E3
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-108
LEVEL 8 LIGHTING PLAN
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURAL
ENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEP
ENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICAL
ENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTING
DESIGNER
1/8" = 1'-0"1 LEVEL 8 LIGHTING PLAN
25% DESIGN
DEVELOPMENT
15 JAN 2020
M2
M2
M2
M2
M2
M2
M2M2M2
M3 M3 M3
WW
E4E4E4
M2
M2
M2
M2
M2
M2
M2
M2M2
WW
A2 A2
A1 A1
A1A1A1
M2
A1A1A1A1
M3 M3M3
M2 M2
ST1
ST1
ST1ST1ST1ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1
ST1ST1
ST1 ST1
ST1 ST1 ST1
ST1 ST1 ST1 ST1
ST1 ST1
ST1 ST1 ST1
ST1 ST1
ST1 ST1
ST1 ST1
M3 M3 M3ST1 ST1
ST1ST1
ST1 ST1
ST1 ST1
M2
M2
M2
M2
M2
M2
M2
M2M2
M1M1M1M1
M2
M1
M1
M2
M2
M3 M3M3
ST1
ST1 ST1
M3 M3 M3
M3 M3 M3
M3 M3 M3
ST1
ST1
ST1 ST1 ST1
ST1 ST1
ST1
ST1ST1
ST1
ST1ST1
ST1 ST1 ST1
ST1 ST1 ST1
ST1
ST1ST1ST1ST1M2
M2
M3
M2
M2
M2
M2
ST1
ST1 ST1 ST1 ST1
ST1
ST1ST1
ST1
ST1
ST1 ST1ST1ST1ST1
ST1ST1
ST1
ST1 ST1 ST1 ST1
ST1
ST1 ST1
ST1
ST1 ST1
ST1 ST1
ST1ST1
ST1 ST1ST1
ST1 ST1 ST1
ST1
ST1
ST1
ST1
ST1
ST1 ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1
ST1ST1ST1ST1ST1ST1ST1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:
APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-202
EAST & WEST ELEVATION
21222.00
Designer
Author
Checker
Approver
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300
LAKEWOOD, CO 80401
MEP
ENGINEER
INTEGRAL GROUP
3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREET
DENVER CO 80204
LIGHTING
DESIGNER
3/32" = 1'-0"1 EAST - LIGHTING (OVERALL)
3/32" = 1'-0"2 WEST - LIGHTING (OVERALL)
25% DESIGN
DEVELOPMENT
15 JAN 2020
WEST LIGHTING PLAN SCALE: 3/32”=1”
EAST LIGHTING PLAN SCALE: 3/32”=1”
NORTH LIGHTING PLAN SCALE: 1/16”=1”
LEVEL 7 ENLARGEMENT SCALE: 1/16”=1”LEVEL 8 ENLARGEMENT SCALE: 1/16”=1”ROOF ENLARGEMENT SCALE: 3/64”=1”
M2
M2
M2
M2M2M2
M2
M2
M2 M2
M3M3
M2
M3M2M2
M2 M2 M2
M2 M2 M2 M2 M2
M2 M2
M3
M2 M2M2
M3
A1 A1
Z1Z1Z1Z1Z1Z1
E4E4
W
M2
A1
M2
A2
ST1 ST1 ST1 ST1
A1A1A1
ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1
ST1 ST1 ST1
M3
ST1ST1ST1ST1ST1ST1ST1ST1ST1ST1ST1ST1
M2
ST1 ST1
M1 M1 M1 M1
M1
M1
ISS. #
4240 Architecture Inc.
copyright 2017
ARCHITECT'S PROJECT NO. :
DESIGNER:
DRAFTER:
CHECKER:APPROVED BY:
KEY PLAN
DESCRIPTION DATE
NOT FOR CONSTRUCTION
OWNER
EL-201
NORTH ELEVATION
21222.00
Designer
Author
CheckerApprover
AS
P
E
N
,
C
O
8
0
6
1
1
GO
R
S
U
C
H
H
A
U
S
NORWAY ISLAND, LLC
ASPEN, CO 80611
STUDIO NYL
2995 BASELINE RD., SUITE 314
BOULDER, CO
STRUCTURALENGINEER
BG BUILDINGWORKS
1626 COLE BLVD. SUITE 300LAKEWOOD, CO 80401
MEPENGINEER
INTEGRAL GROUP3000 LAWRENCE STREET DENVER,
CO 80216
SUSTAINABILITY
GEILER & ASSOCIATES
12355 E. CORNELL AVENUE
AURORA, CO 80014
ACOUSTICALENGINEER
186 LIGHTING DESIGN GROUP
1200 BANNOCK STREETDENVER CO 80204
LIGHTINGDESIGNER
1/8" = 1'-0"1 NORTH - LIGHTING
25% DESIGN
DEVELOPMENT
15 JAN 2020