Loading...
HomeMy WebLinkAboutDraft Resolution.PZ Resolution XX Series of 2025 Upholding.835 E Dean StAlternative A – Affirms Director’s Determination Planning and Zoning Commission Resolution #XX, Series of 2025 Page 1 of 2 RESOLUTION #XX SERIES OF 2025 A RESOLUTION OF THE ASPEN PLANNING AND ZONING COMMISSION UPHOLDING THE COMMUNITY DEVELOPMENT DIRECTOR’S DETERMINATION THAT A PROPOSAL TRIGGERS DEMOLITION AT 823 EAST DEAN STREET, LEGALLY DESCRIBED AS LOTS N AND O, BLOCK 113, CITY AND TOWNSITE OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO. PARCEL ID: 2737-182-58-003 WHEREAS, the Community Development Department issued a determination on November 11th, 2024, to Z Group Architecture & Interior Design, representing Alpine Back, LLC, that a proposal at 823 East Dean Street triggered demolition for purposes of Chapter 26.470; and, WHEREAS, Z Group Architecture & Interior Design, appealed the determination on November 15th, 2024, in accordance with 26.316.030, Appeal Procedures; and, WHEREAS, pursuant to 26.316.020 the Planning and Zoning Commission shall have the authority to hear and decide appeals from an adverse determination by the Community Development Direction on an application from exemption from the Growth Management Quota System; and, WHEREAS, the Community Development Department Staff reviewed the appeal for compliance with the applicable review standards; and, WHEREAS, upon review of the appeal and the Land Use Code standards, the Community Development Director recommended upholding the administrative determination; and, WHEREAS, the City of Aspen Planning and Zoning Commission reviewed and considered the appeal under the applicable provisions of the Land Use Code as identified herein, in particular Section 26.316.030, Appeal Procedures, considered the recommendation of the Community Development Director, and took and considered public comment at a duly noticed public hearing on January 7th, 2025; and, WHEREAS, the City of Aspen Planning and Zoning Commission finds for the reasons stated on the record that the Community Development Director did not deny due process, exceed their jurisdiction, or abuse their discretion; and, WHEREAS, the City of Aspen Planning and Zoning Commission finds that this Resolution furthers and is necessary for the promotion of public health, safety, and welfare, and, WHEREAS, the City of Aspen Planning and Zoning Commission approves Resolution #XX, Series of 2025, by a XX to XX (XX – XX) vote, upholding the determination as identified herein. NOW, THEREFORE BE IT RESOLVED BY THE PLANNING AND ZONING COMMISSION OF THE CITY OF ASPEN, COLORADO THAT: Alternative A – Affirms Director’s Determination Planning and Zoning Commission Resolution #XX, Series of 2025 Page 2 of 2 Section 1: Approvals The Planning and Zoning Commission upholds the administrative determination stating that the proposed project triggers demolition. The proposal consists of deconstructing the existing structure, panelizing the walls and roof, and reusing the walls and roof on a new structure. Section 2: Material Representations All material representations and commitments made by the Applicant pursuant to the development proposal approvals as herein awarded, whether in public hearing or documentation presented before the Planning and Zoning Commission, are hereby incorporated in such site development approvals and the same shall be complied with as if fully set forth herein, unless amended by an authorized entity. Section 3: Existing Litigation This Resolution shall not affect any existing litigation and shall not operate as an abatement of any action or proceeding now pending under or by virtue of the ordinances repealed or amended as herein provided, and the same shall be conducted and concluded under such prior ordinances. Section 4: Severability If any section, subsection, sentence, clause, phrase, or portion of this Resolution is for any reason held invalid or unconstitutional in a court of competent jurisdiction, such portion shall be deemed a separate, distinct, and independent provision and shall not affect the validity of the remaining portions thereof. FINALLY, adopted, passed, and approved this 7th day of January, 2025. Approved as to form: Approved as to content: ______________________________ __________________________________ Katherine Johnson, Assistant City Attorney Teraissa McGovern, Chair Attest: _______________________________ Tracy Terry, Deputy Clerk EXHIBIT A: Existing and Proposed Plans 10' - 0"10' - 0" 5' - 0 " 5' - 0 " 5' - 9 3 / 8 " 6' - 4 1 / 2 " MAIN LEVEL 1552 SF 2 A-1.05D 1 A-1.05D WALL N 48' - 3" WALL M 24' - 0 3/4" WALL K 9' - 6 3/4" WALL I 14' - 0 3/4" DEMO WALL D 8' - 1" WALL F 13' - 0 1/2" 4' - 3"3' - 5" WALL H 24' - 0" WALL J 2' - 0" WALL G 14' - 0" DEMO WALL E 9' - 7 1/2" DEMO WALL C 4' - 0 3/4" DEMO WALL A 20' - 0" Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 5 : 4 4 P M A-1.02D EXIST'G FLOOR PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker No. Description Date 1 Revision 1 Date 1 1/4" = 1'-0"1 Existing Main Level EXISTING ROOF AREA 1701 SF (TOTAL) 49' - 7" 15' - 4 3/4" 8' - 2 3/4" 25' - 4 3/4" 21' - 4" 4' - 0 3/4" 8' - 3 1/2" 25' - 4" 15' - 4" 7' - 9 1/2"8' - 1"10' - 3 1/2"2' - 0"21' - 5" Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 5 : 2 7 P M A-1.03D EXIST'G ROOF PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker No. Description Date 1/4" = 1'-0"1 Existing Roof Plan Washer Dryer UP A-202 A-201 A-201 1 A-202 1 2 2 1 A-301 A A B B C C D D E E F F 1 22 33 44 55 66 14 ' - 3 1 / 4 " BATH 3 006 BEDROOM 3 008BEDROOM 2 009 BATH 2 011 GYM 012 WELLNESS 015 MECHANICAL 016 CLOSET 3 007 LAUNDRY 003 CLOSET 2 010 BEDROOM 4 004 FAMILY ROOM 001 1 A-302 WALL N 42' - 7 1/2" WA L L N 5' - 7 1 / 2 " WA L L A 20 ' - 0 " WALL L 1' - 1 1/2" WALL B 8' - 1" WALL D 8' - 1" WALL M 23' - 10 3/8" WALL I 14' - 3 1/2" WALL G 6' - 2 3/8" WALL E 4' - 10 3/8" WALL K 9' - 6 3/4" WALL J 2' - 0" WALL C 4' - 0 3/4" WALL F 13' - 0 3/4"6' - 3 1/2" WA L L L 22 ' - 3 1 / 2 " WA L L G 7' - 9 5 / 8 " WA L L M 1 5 / 8 " WA L L H 2' - 6 3 / 8 " WA L L H 16 ' - 9 1 / 8 " WA L L H 4' - 8 1 / 2 " COLD PLUNGE BATH 4 013 WET BAR 10' - 0 3/4"9' - 8 7/8"9' - 5 1/4" 44' - 4 1/4"19' - 2 1/8" 44' - 3 1/2"10' - 0 3/4" Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 6 : 5 3 P M A-103 PROPOSED RE-USE PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker 1/4" = 1'-0"1 Lower Level No. Description Date 1 Revision 1 Date 1 UP A-202 A-201 A-201 1 A-202 1 2 2 Rear Yard Setback 10' - 0" 1 A-301 A A B B C C D D E E F F 11 22 33 44 55 66 5' - 0 " 5 1 / 4 " 19 ' - 1 0 1 / 2 " 24 ' - 3 " 5 1 / 4 " Si d e Y a r d S e t b a c k 10 ' - 0 " 35' - 9 3/8" 4' - 0 " 7' - 0 " 8' - 6 3/8" MUD 004 BREAKFAST 006 GARAGE 017 PANTRY 018 KITCHEN 019 DINING RM. 022 LIVING RM. 023 LOUNGE 024 HALL 025 Fire Place DJ BENNY P WET BAR 5' - 0 " PWDR 030 7' - 6" 1 A-302 45' - 0" 3' - 3 7/8" 44 ' - 9 " 22' - 6 1/8" 2' - 0 7 / 8 " 3' - 7 5 / 8 " 3' - 1 0 5 / 8 " 9' - 1 0 5 / 8 " 4' - 1 3 / 8 " 19 ' - 1 1 1 / 4 " 10 ' - 2 1 / 4 " 14 ' - 0 " 31' - 2 1/2"12' - 0"1' - 1"4' - 3 5/8"4' - 3 3/4"1' - 9 1/2"4' - 9"4' - 7 3/4"5' - 10 3/8"5' - 6 7/8" 14 ' - 1 0 1 / 2 " 4' - 1 5 / 8 " 14 ' - 3 " 5' - 1 0 3 / 8 " Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 6 : 3 3 P M A-104 PROPOSED RE-USE PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker 1/4" = 1'-0"1 Main Level No. Description Date 1 Revision 1 Date 1 A-202 A-201 A-201 1 A-202 1 2 2 1 A-301 A A B B C C D D E E F F 11 22 3 4 5 6 4' - 0" 14' - 0" 13 ' - 4 3 / 8 " 12 ' - 0 " 4' - 0 1 / 2 " 4' - 5 1 / 2 " 11' - 11 3/4" 10' - 0" 7' - 2 " 10' - 0 3/4" 10' - 0"34' - 3 1/2"10' - 0 3/4"9' - 8 7/8"9' - 5 1/4" 7' - 0" WALK-IN CLOSET 026 PRIMARY BEDROOM 027 PRIMARY BATH 028 NURSERY 029 WINDOW SEAT 12 ' - 6 " 12 ' - 9 5 / 8 " 7' - 3 " 6' - 6 " 9 1 / 8 " 12 ' - 2 5 / 8 " 7' - 4 5 / 8 " 7' - 0 " OPEN TO BELOW DECK ROOF BELOW Infill w/ Exist'g 2x8 Wd. framing (doubled up) 1208 sf of wood framing 1 A-302 MAIN LEVEL ONE-STORY ROOF FRAMING Infill w/ Exist'g 2x8 Wd. framing (doubled up) 650 sf of wood framing MA I N L E V E L O N E - S T O R Y R O O F F R A M I N G MAIN LEVEL ONE-STORY ROOF FRAMING Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 6 : 0 9 P M A-105 PROPOSED RE-USE PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker 1/4" = 1'-0"1 Upper Level No. Description Date 1 Revision 1 Date 1