Loading...
HomeMy WebLinkAboutResolution Exhibit A.Existing and Proposed Plans.823 E Dean St10' - 0"10' - 0" 5' - 0 " 5' - 0 " 5' - 9 3 / 8 " 6' - 4 1 / 2 " MAIN LEVEL 1552 SF 2 A-1.05D 1 A-1.05D WALL N 48' - 3" WALL M 24' - 0 3/4" WALL K 9' - 6 3/4" WALL I 14' - 0 3/4" DEMO WALL D 8' - 1" WALL F 13' - 0 1/2" 4' - 3"3' - 5" WALL H 24' - 0" WALL J 2' - 0" WALL G 14' - 0" DEMO WALL E 9' - 7 1/2" DEMO WALL C 4' - 0 3/4" DEMO WALL A 20' - 0" Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 5 : 4 4 P M A-1.02D EXIST'G FLOOR PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker No. Description Date 1 Revision 1 Date 1 1/4" = 1'-0"1 Existing Main Level EXISTING ROOF AREA 1701 SF (TOTAL) 49' - 7" 15' - 4 3/4" 8' - 2 3/4" 25' - 4 3/4" 21' - 4" 4' - 0 3/4" 8' - 3 1/2" 25' - 4" 15' - 4" 7' - 9 1/2"8' - 1"10' - 3 1/2"2' - 0"21' - 5" Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 5 : 2 7 P M A-1.03D EXIST'G ROOF PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker No. Description Date 1/4" = 1'-0"1 Existing Roof Plan Washer Dryer UP A-202 A-201 A-201 1 A-202 1 2 2 1 A-301 A A B B C C D D E E F F 1 22 33 44 55 66 14 ' - 3 1 / 4 " BATH 3 006 BEDROOM 3 008BEDROOM 2 009 BATH 2 011 GYM 012 WELLNESS 015 MECHANICAL 016 CLOSET 3 007 LAUNDRY 003 CLOSET 2 010 BEDROOM 4 004 FAMILY ROOM 001 1 A-302 WALL N 42' - 7 1/2" WA L L N 5' - 7 1 / 2 " WA L L A 20 ' - 0 " WALL L 1' - 1 1/2" WALL B 8' - 1" WALL D 8' - 1" WALL M 23' - 10 3/8" WALL I 14' - 3 1/2" WALL G 6' - 2 3/8" WALL E 4' - 10 3/8" WALL K 9' - 6 3/4" WALL J 2' - 0" WALL C 4' - 0 3/4" WALL F 13' - 0 3/4"6' - 3 1/2" WA L L L 22 ' - 3 1 / 2 " WA L L G 7' - 9 5 / 8 " WA L L M 1 5 / 8 " WA L L H 2' - 6 3 / 8 " WA L L H 16 ' - 9 1 / 8 " WA L L H 4' - 8 1 / 2 " COLD PLUNGE BATH 4 013 WET BAR 10' - 0 3/4"9' - 8 7/8"9' - 5 1/4" 44' - 4 1/4"19' - 2 1/8" 44' - 3 1/2"10' - 0 3/4" Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 6 : 5 3 P M A-103 PROPOSED RE-USE PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker 1/4" = 1'-0"1 Lower Level No. Description Date 1 Revision 1 Date 1 UP A-202 A-201 A-201 1 A-202 1 2 2 Rear Yard Setback 10' - 0" 1 A-301 A A B B C C D D E E F F 11 22 33 44 55 66 5' - 0 " 5 1 / 4 " 19 ' - 1 0 1 / 2 " 24 ' - 3 " 5 1 / 4 " Si d e Y a r d S e t b a c k 10 ' - 0 " 35' - 9 3/8" 4' - 0 " 7' - 0 " 8' - 6 3/8" MUD 004 BREAKFAST 006 GARAGE 017 PANTRY 018 KITCHEN 019 DINING RM. 022 LIVING RM. 023 LOUNGE 024 HALL 025 Fire Place DJ BENNY P WET BAR 5' - 0 " PWDR 030 7' - 6" 1 A-302 45' - 0" 3' - 3 7/8" 44 ' - 9 " 22' - 6 1/8" 2' - 0 7 / 8 " 3' - 7 5 / 8 " 3' - 1 0 5 / 8 " 9' - 1 0 5 / 8 " 4' - 1 3 / 8 " 19 ' - 1 1 1 / 4 " 10 ' - 2 1 / 4 " 14 ' - 0 " 31' - 2 1/2"12' - 0"1' - 1"4' - 3 5/8"4' - 3 3/4"1' - 9 1/2"4' - 9"4' - 7 3/4"5' - 10 3/8"5' - 6 7/8" 14 ' - 1 0 1 / 2 " 4' - 1 5 / 8 " 14 ' - 3 " 5' - 1 0 3 / 8 " Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 6 : 3 3 P M A-104 PROPOSED RE-USE PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker 1/4" = 1'-0"1 Main Level No. Description Date 1 Revision 1 Date 1 A-202 A-201 A-201 1 A-202 1 2 2 1 A-301 A A B B C C D D E E F F 11 22 3 4 5 6 4' - 0" 14' - 0" 13 ' - 4 3 / 8 " 12 ' - 0 " 4' - 0 1 / 2 " 4' - 5 1 / 2 " 11' - 11 3/4" 10' - 0" 7' - 2 " 10' - 0 3/4" 10' - 0"34' - 3 1/2"10' - 0 3/4"9' - 8 7/8"9' - 5 1/4" 7' - 0" WALK-IN CLOSET 026 PRIMARY BEDROOM 027 PRIMARY BATH 028 NURSERY 029 WINDOW SEAT 12 ' - 6 " 12 ' - 9 5 / 8 " 7' - 3 " 6' - 6 " 9 1 / 8 " 12 ' - 2 5 / 8 " 7' - 4 5 / 8 " 7' - 0 " OPEN TO BELOW DECK ROOF BELOW Infill w/ Exist'g 2x8 Wd. framing (doubled up) 1208 sf of wood framing 1 A-302 MAIN LEVEL ONE-STORY ROOF FRAMING Infill w/ Exist'g 2x8 Wd. framing (doubled up) 650 sf of wood framing MA I N L E V E L O N E - S T O R Y R O O F F R A M I N G MAIN LEVEL ONE-STORY ROOF FRAMING Wall Legand Existing Structure to be Re- Used Interior Structure to be Re- Used New Structure Existing Structure Notes 1. Existing Exterior Walls are 2x4 wood framing. 2x4 wood studs are not sufficient for today's structural requirements at exterior walls. 2x4 wood studs do not meet the Residential Energy code. -Proposed Re-Use: Lower Level wall furring around foundation perimeter. (100% of Exterior wood framing reused) 2. Existing Interior walls are 2x4 wood framing. -Proposed Re-Use: Additional furr-out at Lower Level foundation wall (infill of exist'g window & door locations and for additional height as needed), blocking as req'd through-out new construction, ceiling furr-downs, and Interior millwork 3. Existing Roof framing is 2x8 wood framing. Current framing does not meet structural snow load requirements. (Pre-1994: 40psf) -Proposed Re-Use: 2x8s would be doubled up and used as roof framing infill between new structure. (100% of wood Roof Framing reused) 4. Areas with water damage and mold to be disposed of properly. To be reviewed/approved by COA Building Official Sheet #: Copyright 2023 Z-Group Architects, P.C. Project number: Construction Date: Prepared By: Checked By: Sheet Name: Jurisdiction Use: Seal: 10 / 3 1 / 2 0 2 4 3 : 1 6 : 0 9 P M A-105 PROPOSED RE-USE PLAN SI N G L E F A M I L Y A L T E R A T I O N & A D D I T I O N B. A . C . H . 01234 XX.XX.XX Author 82 5 / 8 2 3 E . D E A N S T R E E T As p e n , C O 8 1 6 1 1 Checker 1/4" = 1'-0"1 Upper Level No. Description Date 1 Revision 1 Date 1