HomeMy WebLinkAboutExhibit B Referral Comments.930 King St
Exhibit B - Referral Comments
HP Project: 930 King Street
Building Department Comments:
Bonnie Muhigirwa, bonnie.muhigirwa@cityofaspen.com
1. Window and door changes in the non-historic addition will need to meet
energy code requirements at time of submission. 2015 IECC R503.1.1
2. Glass guards to comply with 2015 IBC 2407 per Ordinance 40, 2016
3. Grates proposed at window wells shall be releasable or removable from
the inside without the use of a key, tool, special knowledge or force
greater than that required for the normal operation of the escape and
rescue opening force not to exceed 15 lbs. 2015 IRC R311.7.11 per
Ordinance 40, 2016
4. Encapsulate the rooftop deck with code compliant glass guard rails.
Engineering Department Comments:
Wyatt Young, wyatt.young@cityofaspen.com
1. Drainage and capacity calculations for the pervious paver patio will need
to be provided at building permit.
Zoning Department Comments:
Haley Hart, haley.hart@cityofaspen.com
1. Plan Sheet A1.05: On the proposed Main Level, east side, is a new deck
being proposed in the inset area by the new window and new door at the
connection to the historic resource?
2. Plan Sheet A2.02: Same location as comment number one, will there be
a step to grade from the new door access to the rear yard? Please show
height for any step down to patio/deck space. Anything above six inches
will be counted towards the ‘deck’ calculation. Also, any stairs are
automatically counted towards deck.
3. Proposed Exterior Lighting Cut Sheet for P560289-031, Trafford Non-
Metallic Lantern: This light fixture will meet the requirements of the Land
Use Code only if it is mounted 12 feet or less from grade. This light will
not meet code on second floor decks because it is not fully shielded.
4. Proposed Exterior Lighting Cut Sheet for P560131-031, Felton: This light
fixture is non-compliant with the Land Use Code. The fixture glass will
need to be fully frosted so that the point light source is not visible in order
to comply.
Parks Department Comments:
David Radeck, david.radeck@cityofaspen.com
1. Plan Sheet Z1.03: Fence post locations in the driplines of trees will
require approval of the City Forester.
2. Plan Sheet Z1.03: How far off are the neighbor’s trees (on the east
property line) from the proposed walkway?
3. Plan Sheet Z1.03: Is there a tree or two in the front yard?
4. Plan Sheet Z1.03: 15’ spacing minimum for spruce trees.