Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.729 W Francis St.0052-2022-BRES (8)
► 111100 111 CITY OF ASPEN 427 Rio Grande Place, Aspen, CO 81611 (970) 920.5090 www.aspen.gov NOTICE OF EXEMPTION AND AUTHORIZATION TO APPLY FOR LAND USE/ BUILDING PERMITS DURING THE EFFECTIVE TERM OF ORDINANCE#27, SERIES OF 2021 AND ORDINANCE #6, SERIES OF 2022 Property Address: 729 W Francis St Parcel ID Number: 273512427801 Property Owner: GOLD RUSH CONDO ASSOC Representative/email: phil.lehue@outlook.com Scope of Work (Provide narrative here and a separate pdf which is a succinct and clear set of supporting documents, to be attached to this form as Exhibit A, such as Letters of Completeness, Resolutions, Development Orders, Land Use Case numbers, Building Permit numbers etc. If the representation being made is that the work does not involve dimensional changes prohibited by the moratorium provide existing and proposed calculations, floor Plans and and elevations to be attached: Interior Remodel of upper unit. New windows and doors around building. No change to FAR. No change in building height. Due to the circumstances noted below, the above referenced project as defined by the Scope of Work is exempt from the application of Ordinance #27, Series of 2021 and Ordinance #6, Series of 2022, and is authorized to pursue a land use review and/or building permit review during the effective terms of Ordinance #27, Series of 2021 and Ordinance #6, Series of 2022, ordinances which generally place a moratorium on residential development. This authorization does not guarantee issuance of a building permit or approval of any land use application. The applicant must submit complete information and pursue all authorized approvals in a timely fashion, adhering to all deadlines for submission, terms of Vested Rights, response times required to maintain an active building permit, and all other Land Use Code and Building Code requirements in effect as of December 8, 2021. Any amendments and or additional approvals not addressed or identified in the application, may be subject to Ordinance #27, Series of 2021 or Ordinance #6, Series of 2022. REc IVED The project described above is permitted to proceed with land use review beco05/2022 (check all that apply): ASPEN BUILDING DEPARTMENT ❑ A land use application for a Development Order or Notice of Approval was submitted to the Community Development Department prior to final passage of the ordinance on December 8, 2021, and was subsequently deemed to be complete by the Community Development Department Director. ❑ The land use application is seeking a Development Order or Notice of Approval for a project consisting of 100°/0 Affordable Housing as that term is defined at §26.104.100 of the Aspen Municipal Code, or as may be deemed necessary for the issuance of Certificates of Affordable Housing for a 100% Affordable Housing project, or as determined by the Community Development Director. ❑ The land use application involves Voluntary AspenModern designation processes that meet the requirements of Section 26.415.025.0 and 26.415.030. ❑ The land use application or administrative request may be necessary to issue exempt building permits as described below, and as determined by the Community Development Director. The project described above is permitted to submit for building permit review because (check all that apply): ❑ A building permit application was submitted to the Community Development Department prior to final passage of the ordinance on December 8, 2021, and was subsequently deemed to be complete by the Chief Building Official. o It is a building permit for a project that will not increase the gross square footage of development, Net leasable area, or Net livable area of any building and does not meet the definition of demolition. o It is a building permit for a project that will not increase the Height of any building. This includes additions to or replacement of mechanical equipment or energy efficiency systems pursuant to height exemptions as set forth at §26.575.020 of the Aspen Municipal Code, or as determined by the Community Development Director. ❑ It is a building permit for commercial and lodge development as stand-alone uses on a parcel or property. o The project has received or is eligible to receive a Development Order or Notice of Approval on the effective date of this ordinance. ❑ It is a building permit for 100% affordable housing projects as that term is defined at §26.104.100 of the Aspen Municipal Code. ❑ It is a building permit for demolition or repair of non-habitable structures. Issued on May 2 , 2022 , this certificate is valid through the effective date of Ordinance #27, Series of 2021 and Ordinance #6, Series of 2022, or any Ordinance which supersedes a provision of these ordinances in a manner which is relevant to the Scope of Work. A copy of this certificate is required when applying for any land use review or building permit. This Notice is not a Development Order or Administrative Determination that is subject to appeal. 3-'4.-y2en Planning Director, for Phillip Supino Community Development Director Disclaimer: This exemption is given based on the information provided by the applicant. If changes are made, or the scope,after a more detailed review, is found to be subject to Ordinance 27, 20210at IVED Ordinance #6, Series of 2022, the exemption may be revoked. ,PE Exhibit A: Floor plans and elevations representing scope of work 05/05/2022 ASPEN BUILDING DEPARTMENT • Exhibit A NOTICE OF APPROVAL FOR AN ADMINISTRATIVE VARIATION TO THE PRINCIPAL WINDOW RESIDENTIAL DESIGN STANDARD FOR A REMODEL, ON THE PROPERTY COMMONLY DESCRIBED AS 729 WEST FRANCIS STREET,UNIT 1,AND LEGALLY DESCRIBED AS CONDOMINIUM UNIT 1, GOLD RUSH CONDOMINIUMS, ACCORDING TO THE CONDOMINIUM MAP RECORDED MAY 4, 1978 IN PLAT BOOK 6 AT PAGE 103 AS RECEPTION NO. 203799, AND AS FURTHER DEFINED AND DESCRIBED IN THE CONDOMINIUM DECLARATION FOR GOLD RUSH CONDOMINIUMS RECORDED MAY 4, 1978 IN BOOK 347 AT PAGE 409 AS. RECEPTION NO. 203800, COUNTY OF PITKIN, STATE OF COLORADO. Parcel ID No. 2735-124-27-011 APPLICANT: Noelle Hernandez B&G Francis LLC 729 W Francis St. Aspen, CO 81611 1111 1111111111M11 11111111111111111111111111111111111111111 RECEPTION#: 682683, R: $63.00, D: $0.00 DOC CODE: APPROVAL REPRESENTATIVE: Phil Lehue Pg 1 of 11, 11/17/2021 at 11:02:04 AM Straightline Ltd. Janice K.Vos Caudill, Pitkin County, Co 1690 Homestake Dr. Aspen, CO 81611 SUBJECT & SITE OF APPROVAL: The Applicant has requested alternative compliance for the Residential Design Standard for the Principal Window(flexible) (26.410.030.E.1) Standard. The subject property is Unit 1 at 729 W. Francis St.,With a Parcel ID of 2735-124-27-011, and legally described as listed above. SUMMARY: The applicant is proposing a remodel of the duplex that proposes changes to street facing windows. The proposed design is depicted in Exhibit A. The Principal Window Standard requires each unit to have a window on the street facing façade that measures a minimum 4' x 4'. The proposed design includes two window groupings that measure 1'6"x 8'. The Residential Design Standards(Chapter 26.410) apply to this application. The proposal complies with all standards except 26.410.030.E.1 Principal Window(Flexible). STAFF EVALUATION: The project is a remodel of an existing structure. The applicant is proposing to replace a single window on the street facing facade that meets the requirements of the Principal Window Standards with new windows that do not meet the minimum height required. However,the proposal includes a total of 24 square feet of fenestration, when considering the minimum dimensions of the standard only require 16 sq. ft.. Also, the structure contains a stacked duplex -RECEIVED pag®M e5/2022 ASPEN BUILDING DEPARTMENT and the windows on the main level for Unit 2, meeting the requirements of the Principal Window Standard. The applicant's proposal does not meet the minimum size required but Staff has determined the intent of the Principal Window Standard has been met. The proposed window design provides a variety of fenestration that helps to break up the facade and provides visual interest and transparency. DECISION: The Community Development Director finds the requested Alternative Compliance to the Residential Design Standards for the Principal Window Standard as noted above meets the requirements as described in the Land Use Code, and hereby APPROVES the request. APPROVED BY: ip n , Date Community Development Director Attachments: Exhibit A --RDS Drawings (recorded) Exhibit B RDS Checklist(recorded) Exhibit C—Staff Findings (not recorded) Exhibit D—Application (not recorded) • • • RECEIVED pagQ iIfQ5/'2022 ASPEN BUILDING DEPARTMENT . N • • Exhibit A t ] 3C]4 t 1 : f l ��a� I D � �� CD \ 3I `� g g CIA I ! ;.'..5:11,:g!,%,i,_:+ii....., —,. O f I I g 4e F. r� d --I tt I- I 1 I c • i Z ` 4+ x rr G} \ Q Z 9 II41y Id � �� x � � I Iv-iii `1 1 � z ^ Il'Y I • Ild wj �1` iawwww} I ... •• w r ' k.'lp 1i I ICE, s 0 ��4 JJi -.:{ E (I'k ji i�I • Z @ 1 z I !I'�� >w. >.1www H.atawm o ,, n yu C I 11 y2' ^Jg9444 44R4'•si p O - :I I > s "n_-I IiD`iii:2i'1 iiL - Z °.:.'• II''I'1 1 i O — r •,�I�..'a:°i 4,t11. {�1�,L,� • rg w m w r, m w i III siNh -..1 I ,,-.ii�..:31 "7'1" 1514 i(IIEI Ik13f1(i y l _ i �14t4, II =S{ti 9 �F II t�rq'i ilia ! -r p:D� i 1 mat s 1 al n -.q t1,i 1rr - - , .,,, ._... .. „, ,,.... .........,.'4'....,.. n. fI. • ,:i 1 i 1 jl;ik iI - FQ( I pi 11-1 I -e JItiiI,IIIII�, ` ;;; 4 I}{^1 I l�lE! I IJ' y l 11�'' tii t f i tll _.- .� 1 E I111 bill �mlal ; • -- - fr li,il .{hi ±j-'. Il ii 1 11 ''1�'i .r'1�� )- k! ( 1, • .......•.,r;•:_.:,•- .,...'::,1111111111 s,0,,,,,,.e,,,,,,,I,,,,,f,,,,...,.„.„.„ . ly t� $i. kk ( ▪ 1l{ {f���1y{ 1 c ;Iiiil.di 3t1 II,ll(, : i l [_; �, /.,41�, 1/ I I i a U t Ell I p m RG !^p DI L� o m y Fri 4 *zz �S ookg 1 h. F�4'� dry ^ g f x§ o Q� gg s g �i°p N5. S� 3Y F n P ' n z wm gilt. y Y---� ,. t• L n g f.goz zs IF t x i.'i'ii. r l , Y 7'. oc o �� c+ rxo!ryzo ww gg�"'+ g,4 �:tkt \`\�\\\\� p:- 1 i 7 J I'.i ^ pj�5�.i 4.�. lag f__'f, ___' g i3,� •;«: • �' k'°a I gi .f ; 4 !'' d• � 159 zg p•9W gCIwE ,,o A Ow .6 : 117Xt i--1 !p€ $ §z • b^ ��giss�a$£�rapaq >��z 'laa w r� �..._J L" .'�. '! Tt al c Crl�DDo�' -t �oT Ill�i'�G• u oo �J Ir` Lei 1 1 �+ y 4 . 2 Am � ID �� ?Llf t1 g 4 NF�_r Lr 1 Y • 1 6 +�o "os9 rD oz°o"' L € I a z ni�SgrA �SEo '#; '1' 484 E Fs F. g,:,,:.,,: - . GI �ii'i L��_J RA.i � � • ng agp �Z•'> <o �- m Igo a.. ... tii �.44' a "�a,a , ono zcs`i.+mp"�z Ap o „F \I ° 1I 1 ? olmn i9 o-n f : Ily i' of ' E< ag �. ....H. _.,•;.,..,..d1 s5 0. 85, r, .55... -,-•z ,o0 1•.•:,• � of Q g , I, . T _ 1t. a 1 EIS Alit v^ xy .. ,i� aufk 4 y 1 .! s g 2 nn © � _� y I -ni p ,, • 9,, `ov` • ,��3t`{ � m 4 V:.. n GG ® �m� C I � 'to8 �n 4' R �a>;� FAT. 4a ;� ;^ p 2 01�// aY;�B �+�3 I;e4k F .. �� �i a atF xRF � iMENT i 4 ::; of Exhibit A ..-1 .. ' ' .-,,\ ,, ' "\\`',„',,. : ' ' •'': :,- r, ' '" \.:\,\ , : O Z _ \ h .Iii..5t�-.uraBS.q,,..7. 1- l'•y"il' .4 ,A .rt�'. -"7_�i l: . ._- - [ Hi\L \ r 1• o p E E • .. ., m I Vo a , 0H o aH � __ . _ .. . _ _ -- - ` I �i ' km f l '11 ill } m 3 it n ii_ V i� { (' L .--7. !I—FF:1. x �% I - i�uI "4` - V j Y nl a mood g lf(1 H Y III t "'Ak' � Q — l — � •� . I — a� . ;'-', • 11 ill i gi_ -r { i 1 1 —, t g g�o 9m ill 3 1 [ + f r+ ©t 11' o . C9 ¢ R j 11E1 7 ), H ' 'µ v i q u 4 4 ��4 4Po�ao P 4 r tz"Iii g**" g gA 4 I v t O O O a�p8 Y r S�1]� E � x aP o Fei'i¢ has on qCm c`�qr� �m"�1 x� �tu-S �'cmr�i�aG �$`u czi�'a$St"'IAm goo < � yxc o'llgillggI fAitl�' i CPngggcgEtigi•ooYR .. 1511° i�a`li a !Fgrigo pa R "3 ggE Al a g 1 AIP11gf s� z�z `- $ � � azz ac >� tla 88 F� 000c� i1� Ig 1 czia gr5"4�jglii �n§� 11 Uo�9a '� g. nog 2N g g ,,- y. �c' Sm '2 ii �"m�y >+y� ,IRLy.p og9•e o Qpo94 u ittZol yZ mil AQ _ B 4 ..o FAD C l'i SJO b SO rO "?:41 �`y^ D 0rt g Z FA.0§2 O AOm04 G =ffi l E i• g NU a{� o:190 ., `6'gp0 _A A al qg, Ot § i11y<AI rEa., P ga0� ; pp p pk g� a.�yy3{� 9_1 vo�o$ o" o � S�aiU L~L D .: gya� Sg �i.D � jy�tg��o� A iV� � �b' r i' c _D4ocr 10 rt2+'� 5t < E•PpF O'3' §Sd5Z SO5i° 2g• 1 4 . g.-6 Yno% ,+§oaogsm i u$zD� oii bia .40 p. ,o`tg : oti`LoS ,l!mozfi �;.y�, m"o gg �,g�s$ipt.� � � szQ$o+�r,�mtio� Q � � pa � o�� `� �9 � _ ._ S �J 9�+ r o = O y Y U O a5^,1,14t �f 5 I ok elg 28. g•om N.a.�. 68$.1 7. 12 g 'gr a -1;Mib',-,. o 4 L°z P' "A`:," 5 g PO �0*o tht eO O� tllm$_y�gB aAp :.., �i14}1 Kd D Bono apace �? ?p oN., f b' �^ r�i R7 i `3_ F I- O i m £(g' 1" D w dt:.•.:. s ,p5'Y _Lr_ 4A a a i g 4 a So s -x z 8 A o �° ElS 24,1 .^'a 3 zF B 0 'va'" g- l ' S Al o 2 a V. o m g R >I g �°A AE,p n+ w+ i g g 0 2 n ® A O y o g _ RA D a M ®s!;`. a z Fi 7� m A a18 Acl - >D z z a E::S. ti m..o• _� —....a • . ® 1 my`io 4 i 1 *J z� g " all;a5tl'��e 91 l_ d 01 ' 2022 r=l ti r g o i*5 O-n Qn aEeigl1 ge m, n .,R= y nir.� m $ A ark 3 n 0 coo ; RR zoo pz .,„„,reir" g g z �_ �mZ WO-1 yo CAL ➢� hs� �nnsv : a • f v € m wO g kFs� ��8pou r; �d I R .. II g ;i b �.0,,, y _ IR MENT _0 `"1=t1j `�; _0 Exhibit A d +moN � ih off, rim • �\ ��\ . 4 :. \ 1,1\:::\ e,Q I* a .` �I xA a 15s i 6.Y Y->• COT - _ CO ,1 zp . lT q +agg 3 �/i eir- • 1— Q ARE ,. L L�. 0 p�� r • 'j ^ 'k2.ey. T aa — fi .. ... . .. F i'- -- o `� ❑ ._•i_5 6� �f fO 8.•z .. I �." LL11 .. , � F ; �L� a , —, , ,. ,„ . girl-- , • 1,1 ! ! !---,!. , 11 ® r £ �� I I R - . � s t-b . . s spa .11 ,� $ �in� c'�*z'i':r:.; czi -$°'''i6, m q4vo a2c 'ID2E §A.z P88888la�E .• s ' 9 �k_1,Z1i ; 1 •1g zyo> a o �n Cfid elzili.{nLt;l M ci c� $ ° aci°° �.; �z ��15 x 'mv� o �f�zgF�°zz $1g,z�gs ����az �Agppz� �m9 F e c Q6 � � � �••.p ..� Mg-4 n�a'" 4 £ oQToz QR�5�nc° zz 4m24° " : g o II11 IHiI' PF 1.Pc syA, ... EI os a as ' F, Fig q ''j O . ,_ E Iv Fg11 E a G 2 5T 52 1 ; 1O°5g115091, 8 $ 9 Q E901 g a Am y2 2 7 a �L g O 8 ° A �,g,�n0• ° p fil rSTI N: ° U o . 1 tt 'm n `' .E g 1 RI ' ! C a ° Spa', p n p z nil t gg g ED , _ _ _,___ _ a1 ° L O _ _ _, _ .._ _ � � _ O_ � J S. g3 nn may. FR E �� - �� A > C 1 gt1 5. YEA= g I� Q �^ i 5 F �a £ Theo y z., �� c 0 p p s 1 $+p;73,3 >saa��� �Qj t3 �D5 2 22 i _ NA AyVy E} A i MENT 1 c —% FF a eiftk • Exhibit A :;:,.. "C [... •�� - :1i1:11 _ - , II ; o Z '7I1 R� e �} i � � .. ,_HL ,..-,..-- . ,_ __. .., , ,, . :, .. _ I .,1 9 .:-:;:-.v.,:i----:: -''.! -:',E.. , '.....E.1-1--::'::: -..1 ':::.:1_1...::::. :.;: - :.::1: ; jL lr " J-- . r-p-, . „ ...... .:_:_. .._...,_.::.:. .,..::::::,.. :„...... . _...._. ter.._ ...... __....... mTT qr Z _ A{ ' p =i -� ' Ir f • are4 a ��i IrIf iI - 'at� � � a ,s • gZ' i �R BCF � �$�� D iTo �AY A E z R, ! o : && i o 0 m % • g o "; ® K . i ... - _ Ipso .. a .. -. M OR St mc zst : 22h- x fit- j _ gy O/ 5/„ g ` g �rz _ a a m=-n 1 �o $ ^: zagEm �z2?„ -_ ,Rs & 4�ja e8 - - s� r s � zSo • to vti4;i. ;@NROz�= ggz 'k i y-,n n g a0 ocW m iMENT • P4 R1R;§ t S' i5 z' iFs x titk t, ;LIP tYtv4.0 ;�. j rr t - T- M. L I D €--W` i j Ll0 ® © a: ' !I ' " 76 '� 1 y 7 i F '-: \���is 1 i I 4 Z �\ I I ::: ; • l y g ,11 i e isil Q , i I`I I m .... utt1— •' o- ::::F 3 i \- 1 .1 1,,,,,,.,--..,,,,,,p , ,,---1,1, , :71 -7.- ----.1 1 -- g g I g 08 .2. :,-v 100 ' '... , . . 1= 1— to .;.,. O --it I . -I - _ .. _ 3 r s— r -1 F TrCC C ..... 1�� j —. —..._�.�.� I L1 Im A LEDAAA A ,13F - , _ ., o —•- - •.....:,-,......._=,1,11- -.:::) jiii' ffi • 1 Bit 1 . . ,„. .,- R N ! zi ➢ al .c.. .1..„..._• ----,,., ,,.,- ;:.:..,..: ; I1J • ..1. 1 0 4' ''''' , it 1 - _i i, :�.€ YY :!"74:!::g..7 y �o��yS ( :=-1 .-T ._ t m ._ _: ..I I, yy .._ t___• �666 AbA op • o v w t �� T'}4 4 M li*R E, So —S 4 R44? �...L - ! ppp-11: a3e F m t Y J L. — _ aipa — I � [Li rh M ' $ • m .O zOC miu'm� � zo�Oa p�OL — .... laA 11 ,0 1 il ! i CI T :3 2 o ' 0 0, i -giz z F z z b'oz.:- • 1__l I =- 1, E�j @ 1- 1 1 I 1 _ 1 4rE 1 t'�m 1� o Pgs1<0im .:r, I € I 1 � __ -F I ;tip � � o� oSy Zw mmaC S Zti�a •:• 1_� I 1 I I y iG H Pms pro Vp �o° Fa S� yy ICI o �il' i. �:',, > .I 1 T., I 2 __ j e: I z li A y aiIA"l li m3 ;algoggr''' r._s r'1 v 1 ; { o +egggggg i�mzo Gam:: r.,., i l I ! 1 '.1 1 l^ a a 'Z mm as ,E..pa ori.,. ! r to oa_o ♦Q.., i. �r 9t IMF F q.I I V ;$sa. = Z�i3 Cm _it-__..__� Ni `�, __1 I� �s RGGGGGG���iii so �D T-i RR..I. J 3 r, $ - hoS =1eNo 4m Eo _ L.•'^_a. NL_ ___� q 1 El Eg 9s�°'M fin§' W oa z Go Z m 2 L___.._ HI P 25ati IF oi _ . _ .. ' ;4 alq a VEI) q �'�i 2 N 7 1 .. g �5 i Z•i 1 1�� 1 li3 § § 7 .q G - 1, 1., 2 /]/] fY•/l $ Z o F + Zd m j ���ed� � g� ,`�w E p.J G G a Q m 33 g N 8 0 z P z °go ga d,12'Re K0na e@ a -� Z _ ma n � Dp - �� 4s�� mC) it � ������a,4 het: C') --, o .a .s- m q9@9@psi \I MENT r o I IkS C$ Mx gni J / R ;1 ' y • ;lefaE«ns €g� 11-- gS , a z... D 0 W LoG] co m 11 F J In o g€ i s n a x-lig x a s s_ iga , I Z i 1‘' 6' _ ._ •C D 1 I Fa ,I € 7d. gg - . �. I g�= a be � } , p g Z `R : I GI ,i,,_ li . I; _ � sGS D `` Ilj;;j I m — I, I i 11'.1� �a -i r .:. ( !'kg s�tl ,I 1, -._ IT) - - „:j.,,,,0 i$ O ... _— I I _ c c c Rump . L I .— r -_ L i 1... 1 B e *r.. m m ' ice' \, Iti '.-, -{ F . ..u,�.�, __ - , `I ' ; - *f8�1 $b ** . .:..._ ' 1 b W o m m " -- -fit.....-:€ I'U L1 ill1 E] I ¢ [1•.. S :II', - f 111110 v _ oE�p : _ - �_ _._=i! ! 11 ry F'8 c,3 y A. chi P �i czi c�i c�m �.(��� �) �1 __. /art II q �F "S2 " A g • :X, o- - 0 �! `S "�r�'o'�it�" FFFFF �', if p m 1 ..._ D E Y A i Z Z;D -3 N 3 (11: m 2 —.—. _..—.—__ — f-_ { w• -. w w d, 'mob `' m --- 1 4514 f I1 g z. Q _ z;. a ne ->a aFn.aW -- 13 °rb (➢,' o Y 7S�i1 C FSFS 4 ; — •g ,'`yam' '" T .o I rf - LI wi My . R'i �'.�n�n .$ i x' $ iris z • ;&8s o �88� )$f8 o o P • zz iz zz z za § i 4 T--I .iI s 1 b o rgygiiilg;2i o i . I pp��zBvon _ UiO . 1-== i 1 , I -- I I {I I m g a As , Rg.glasln 'i:•:..i 1 f aIF 1 I I o3rimmsi -, E L. d� Ellis r _ ,.._-.1 ;:_ �- i g F===i 11 . o ; ® quug a 3 -=a R m EI , _ :1 w 11 1 1 I M _ I` '�� 8 '-^ i�y�1n 21n ppmszzy oy. ? :_rtiy{ k I 1 _" _ Ue a� yua aQ �� YI -�� _... 1 _� "0 1 1 V Ng' i3i yy0 0�1 AO, - gl T O 0 yt -cr ...___� �� Tr I'I zii Cv 022. O VtA III 1 G 1 deb' € i m P ui a �1iio _ I , • I • -.� - pia ED . p94 1 >,, E �. NS ,rol A =n yg RR 1 omOx {O Z �` i acl d ;g n pridx S ">"e O5- )5: 2 22 mA c g n ZIP ' a �� ?� _ g 7 ® D DO 3 S 00 coo r m >?F Aga fir; w ci —$ . $— * 8to l3 Ap� g-RN..E.}� a " ,co g n €.. m17,. _ o iMENT atL......_i r. { •1 i ' yF,• •• •• ,!s nm �b �F � 1 t .•a Z -m0 py N' r - rc jYzrl ."' ,� ,l ,:�' U ! `_ D its -m _ .-- g f 1�m � i_.�; • • • tltJ f^ 4 — yF f!l u • 40 q.t$�' -� a"' z 0 • .... sm r m • �-1 - .—i _ _, z m ' —+ ill„‘r. r ' I (O , ' li m, ,, �'D • �` m � � •4 ; i g i �A 5L5d ..� . • • �A jA. k i 3 - „ . P2 Y • a O ai l ' • • O Il u} i j zi �v t•_• � it--.-". F'.:- o gg�3 fi Z `, �' • 5 i 361i55° to • r ..@s• t •• l- ct F � - e r y, i m S 1 m �` {yy{�ty� _s s ct, 1 3JT' £ j• f'i d b�ki • i I. S! £ 7n�s ti:: � I� FBI � � 1 .: J r P rb t r a s� --i . • Y �. 4 i s � l{tom-. �;..� "y f 3 xe4 °-0,,,...„,,,,,, 8 • '4j 3 • -�- F q , k ti w� •Ste+' y ` z 7 /1=ii .-'�". y� ` = VED `. • , . i ^, ,fi - 'Si . mai_ ... ... .max i.., x' 1 .._� _r ,x. `✓?,:.`,��,s. - -_ Nish.. .... ,- - v.-5.... ! - _..�. M R di. . ' . . . . •. ... . . .... . . • y� D� 33 �� t� i yy € t.a 9'R p(y70(A F a m{7D Tom4 �9 G h}: 9Q.g5RN a� ;, I C nn F 1 �� 10: zzr Qo -fi3Q RCS;�' R 8 l _I`'�`., I o� _ �. _i � 5. m4,, pEu= TMENT a m N ! o F ,. 5D Exhibit B , b r'd N w 'd � P ::,� ��SS .. • : erg , , = ry t'�e 1- • o m m :.. ... ..::..' ... ... '., . OCR ; .: i �. 1 M M 0 } , � I tl , ft . ... .. , r-� o11 let.• ..,..:.._....:. .... . co Illitik 41;141 4c :.:' ''3 .. .:...: �..: . .: : �• • ca ....................... ::.: : m. m o o :. . . . :o • . ... .. .. :.CD.. . :'.: cb :. :cD� ip CD � .� : b� . . Cp � CD c� :..:.. 0- :4. : . : o: b `° P w Cwi . ..... ro — � A crq O I € • o *�o ro Fc)oco o a X Z a,....::::::;,.,.-......;:::::.::::.:::T.:,....i..:::. ...,:...:.:....::::::::::.....::,::: ::: : :::-.....::.::::1::: ...-::::..... ....-:::. -. !.. ...." ...:::: :, !, _ ,,z, d b PIUJIRECEJYED :. � 2 :.:::-....:.:.:.::::.-.::.... .....,.....:::..:.:„.:.:,:. :.,-.......... ::. :: -.: -:. .,..,..:........-„..2 _. .._ ..- .L: .........:._.:.,... . ,• . _,I. ,A.., . ,gL51, R.' r_a , ,,,,,....,,,I,,, � �1 an. m� 3 g � m 5/0� ASPEN • BUILDING DEPARTMENT • Exhibit B • d :o'. • • • ': ......47r3 ¢ m,o , }x ,:Ti krS hid•'. 0 : [ f ski rc4 .. . . • • • • .. x. E. CD i b f ' e-4- ovate ...... ro ; j k . .#. 1. • �� ti r Q U7 ;....:111111111 Oxl A. II ¢CD * zn A.. ,"r • • iwR.r �7 ..-f a ......::::.,::;:....",......::,.....-(L). .;.,..............-;......i...-..".•..,......;;..........••••• ,..;.;;;.:;,....f....,.....:.,:-;:,.,.::.;,.....i.:::::;......:;;:.,.....,•,:••••••....6. ::.....-•:;!;;;;•:. ..-:,....",:.::::;...::...-. ....::•,:::.....:•.:.::.- ::;..•••,.:•.-•.•::•.••• E:.- '; 1;i.FrEivED .;::::;::: -........:, :: ..: .,.... , : :::::......r.•,-..:,-.::.,: .,„ ......-...,....„.• ..-... ..-. •::::.: : - -....... . - -- • .... . , ... .:::::,,... ..: t,' , a-,,5/05/2022 ASPEN BUILDING DEPARTMENT To: Planner of the Day City of Aspen 427 Rio Grande Place Aspen,CO 81611 970-429-2764 From: Phil LeHue c/o Matter Planning&Design LLC Noelle Hernandez Date: 3/28/22 Re: 729 W Francis St Moratorium Exemption Application Dear Planner of the Day, Thank you for the review of this Moratorium Application. The scope of work for this building permit meets the moratorium exemption criteria. The proposed work does not change in the building height,does not add Gross Area,norNet Livable. Additionally,demolition is not proposed. Details: 729 W Francis St Zone District:R-6 Legal Description: Subdivision:GOLD RUSH Unit: 1 Parcel ID#:273 512427011 Gross Lot: 13,548 Total Heated SqFt: 1,319 History: • 1955—Construction of one-story,single-family residence. • 1970—Addition of second story dwelling unit. • 1980—Permit No.2918:Remodel with addition of 1 bathroom. • 1985—Permit No.08165:Remodel to upper unit,add entry with new deck. • 1998—Permit No.8-218:Interior remodel,replace some windows,new siding&sheetrock. • 2010—Permit No.01 19.20 10.ARGR:Face lift remodel with new finishes • 2019—Permit No.0090.20 19.ARBK:Lower level interior remodel. Moratorium language Section 1:Moratorium on Land Use Applications • Land Use—Notice of Approval Issued November 11 t,2021,Reception No. 682683: Administrative Variation to Principal Window RDS • The existing FA remains the same. RECEIVED 1 05/05/2022 ASPEN BUILDING DEPARTMENT Section 2:Moratorium on Certain building permit applications: • The proposed work does not trigger demolition,does not increase in height of the building. • The proposed work does not increase to gross square footage,nor Net Livable. Section 3:Exemption from Moratorium for building permit: The scope of work does not result in demolition,increase in gross area,nor net livable area and there is no change to the height of the building. Proposed Scope: • The development is a legally established stacked duplex dwelling unit. • The scope is an interior remodel to upper unit with changes to exterior doors and windows. • The proposed window changes have received Notice of Approval on 11/11/2021:Reception No. 682683. • The interior work proposed includes minor reconfiguration of interior space. • No changes to floor area. • No changes to building height. Attachments: • Moratorium Exemption Application Form • Architectural Plans. • Notice of Approval—Principal Window Variation • All history documents are available upon request. Please call or email with any questions. Kind Regards, Phil LeHue 970-456-3887 Phil.lehue Aoutlook.corn RECEIVED 2 05/05/2022 ASPEN BUILDING DEPARTMENT A I B 1 C I D I E 1 F 1 G I H 1 J SHEET kSD* DOOR TAG PROJECT LOCATION ,i— SEQUENCE 729 WEST FRANCIS STREET PROPERTY LOCATION 1 -0 NUMBER all WINDOW TAG - ""..R n ADDRESS: 729 W FRANCIS ST ASPEN,CO,81611 MATT E R YW,""^s LEGAL DESCRIPTION: SUBDIVISION:GOLD RUSH UNIT 1&2 SHEET NUMBER .Nana PLANNING 7 11 ". LEGAL DESCRIPTION: LAND USE 1112:RESIDENTIAL SINGLE FAMILY RESIDENCE 7 + D E S I G N DISCIPLINE C1'0"} CEILING TAG Cr road Church Aspen LETTER OWNER: G+B LLC Q OWNER ADDRESS: PO BOX 1045,ASPEN,CO 81612 IGB1 MATERIAL TAG �",, ,wa PARCEL ID# 273512427010&273512427011 NORTH NORTH ARROW ` Aspen Ranger Station 729 Wear FranCia Street ' • REVISION TAG ® 'ti•'<_ j :1.Si BUILDIN I - ON AS PER PITKIN COUNTY ASSESSOR ',Hallam r BUBBLE ATB = s NCH DESIGN,LLC DBA TT STRUCTURAL a �; Imo- PROPERTY CLASS: DUPLEX CONDO IMPS MATTER PLANNING+DESIGN LLC _— AREAS OF pens Rental co _ - ACTUAL YEAR BUILT: 1955 299 MILWAUKEE ST STE 206 DENVER,CO 80206 GRID LINES REVISION 970-379-5401 I www.matterinteriors.com West End Splendor a"" r i EFFECTIVE YEAR BUILT: 1994(UNIT 1/LOWER LEVEL) BUSINESS LICENSE 12685 By Frarcnupe. - - - EFFECTIVE YEAR BUILT: 1995 UNIT2/UPPER LEVEL PARTITION w .0,,,:" ( ) PROJECT TEAM NAME WORK POINT, TYPE : ^$ O Aspe^Hatp;paispcety"'°""r o.- �z' LAST REMODEL: 2016(UNIT 1/LOWER LEVEL) EL.ELEVATION ELEVATION © �., EXISTING EXTERIOR WALL: STUCCO(UNIT 1) LEVEL HEAD DTL — NOELLE HERNANDEZ QHuiyard Park _ EXISTING EXTERIOR WALL: WOOD SID AVE(UNIT 2) NOELLE@MATTERINTERIORS.COM 6 A.4".. "°,7"'" we r .7 PROPOSED EXTERIOR WALL NORTH&SOUTH STANDING SEAM METAL WALL OVER EXISTING 6 NAME SPOT DIRECTION Q M. SORAYA GALLEGO ELEVATION "a : FACADE FACADE EL.ELEVATION z VIEWED CN ns a ce so y © u y SORAYA@MATTERINTERIORS.COM "ae„„„ n + PROPOSED EXTERIOR WALL EAST&WEST WOOD BOARD&WD BATTENS OVER EXISTING WM/ Aspen V.Mee Spa -- — ` NICOLE STEWART ROOM/AREA 1 IDENTIFICATION Forum Haan co Q Architecture a un9=� �, FACADE FACADE NICOLE@MATTERINTERIORS.COM a A6_ D ELEVATION € a R cture I ei«alvnnng € V 9 • FLOOR:GANDPROPOSEDINTERIORWALLS. DRSE YWALL NAME SHEET WHERE 0 ssi� a '6 t, 't ROOM/NAME INTERIOR Harmaeno _ - •+ _ _ - PROPOSED NTERIOR FLOOR: WOOD AND TILE AT BATHROOMS 1101 ""`"N"- CnneAeneaaOl --0` Y+aAq x r' FLOOR HEAT TYPE: RADIANT FLOOR HEAT SYSTEM NOTES ELEVATION IS ROOM/AREA DRAWN Google a Aspen\ ! ""3 ose NUMBER HEATING FUEL: GAS ROOF COVER: METAL(EXISTING) DRAWINGS AND SPECIFICATIONS DESCRIBES THE 729 WEST FRANCIS ROOF STRUCTURE: GABLE/HIP(EXISTING) GENERAL SCOPE OF THE PROJECT AND DESIGN CONCEPT IN TERMS OF THE INTERIOR DESIGN, PROJECT SYMBOL PROJECT MAP NORTH STREET VIEW NEIGHBORHOOD:PERNEIGH NORTH WESTEND ASPEN ARCHITECTURAL,URAL,MECHANICAL,ELECTRICAL,AND SUPER NEIGHBORHOOD: CITY OF ASPEN PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-O" NECESSARILY INDICATE OR DESCRIBE ALL OF THE WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 SQUARE FOOTAGES AS PER PITKIN COUNTY 5 COMPLETION OF THE REQUIREMENTS OF THE CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, ASSESSOR: DESCRIBED OR INFERRED,THE CONTRACTOR SHALL LOWER LEVEL-UNIT 1/LOWER LEVEL: 1,371 SQ.FT. DETERMINE AND INCLUDE IN THE PROPOSALS ALL GENERAL NOTES ENERGY CODE NOTES ITEMS NECESSARY TO PROVIDE THE PROPER UPPER LEVEL- UNIT 2/UPPER LEVEL: 1,379 SQ.FT. EXECUTION AND COMPLETION OF THE WORK. A. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT,THE GENERAL A. ALL NEW BUILDING COMPONENTS AFFECTED BY REMODEL TO PATIO/DECK/BALCONIES: 478 SQ.FT.(EXISTING) GENERAL NOTES: NOTES,THE SPECIFICATIONS,AND THE DRAWINGS,WHICH ARE COMPLY WITH MINIMUM REQUIREMENTS SPECIFIED ABOVE FOR TOTAL HEATED: 2,690 SQ.FT COOPERATIVE AND CONTINUOUS.WORK INDICATED OR REASONABLY L CLIMATE ZONES 7&8. ALL UNAFFECTED COMPONENTS N/A PER 1.ALLDIMENSIONSTOBEFIELDVERIFIEDPRIORTO m PROPOSED: NO CHANGES TO EXISTING SQ.FT. CONSTRUCTION AND/OR FABRICATION. IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH re CODE. — FULLY COVERED IN ALL.ANY DISCREPANCY BETWEEN THE DIFFERENT • ISSUED AS FULL SHEET N. B. PRESCRIPTIVE ALTERNATIVE USED:NEW WINDOWS TO HAVE U PARTS SHOULD BE REPORTED TO THE DESIGNER IMMEDIATELY. o ISSUED AS SKETCH ce o 0 0 #OF STORIES ABOVE GRADE: 2 PROJECT I ISSUED FOR INFORMATION ONLY VALUE OF MAX 0.28,AND TO BE SAFETY GLAZED:2015 IRC R308.4 B. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND > > L' C. UPGRADES TO NEW LAYOUT AND ENERGY CODE:*MINIMUM OF UNIT 1/BEDROOMS 3/FULL BATHS 2 ORDINANCES;AND SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF g3 75%OF ALL LAMPS INSTALLED IN PERMANENT LIGHT FIXTURES UNIT 2/BEDROOMS 3/FULL BATHS 2 729 W FRANCIS ST CRAFTSMANSHIP BY JOURNEYMEN OF THE APPROPRIATE TRADES. MUST BE HIGH EFFICIENCY IN DWELLING UNITS(2015 IECC R404.1 #OF STORIES BELOW GRADE 0 ASPEN, CO, 81611 C. UPGRADES TO NEW LAYOUT AND ENERGY CODE:*MINIMUM OF 75%OF ALL 5 5 g &C405.1) LAMPS INSTALLED IN PERMANENT LIGHT FIXTURES MUST BE HIGH EFFICIENY 4 IN DWELLING UNITS(2015 IECC R404.1&C405.1) ' ROJECT SCOPE DESCRIPTION 4 D. THE GENERAL CONTRACTOR SHALL COMPLY WITH AND GIVE NOTICES SHEET# DRAWING TITLE o S REQUIRED BY AGENCIES HAVING JURISDICTION OVER THE WORK.IF THE 1.PRESCRIPTIVE ALTERNATIVE:USE THE VALUES OUT OF TABLE R402.1.2 FOR INSULATION AND DESCRIPTION EXTERIOR UNIT LOWER LEVEL:REPLACEMENT NR E GENERAL CONTRACTOR PERFORMS WORK KNOWING IT TO BE CONTRARY FENESTRATION(PRINTED BELOW).YOUR DETAILS,SECTIONS,AND/OR SCHEDULES MUST BE NEW EXTERIOR WINDOWS,NEW FLASHING, TO LAWS,STATUTES,ORDINANCES,BUILDING CODES,AND RULES AND GO-00 COVER SHEET • NOTED WITH THESE R AND U VALUES. DOORS AND NEW BUILDING EXTERIOR FINISH. PROJECT TYPE REGULATIONS WITHOUT NOTICE TO THE DESIGNER AND THE OWNER,THE GO-02 FIRE AND FAR PLAN DIAGRAMS • 2015 IECC TABLE R402.1.2(AS AMENDED BY CITY OF ASPEN ORDINANCE 40,2016) EXTERIOR UNIT 2/UPPER LEVEL:REPLACEMENT FOR NEW CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR SUCH WORK AND GO-03A EXTERIOR SCOPE OF WORK ITEMIZED • EXTERIOR WINDOWS,DOOR AND NEW INTERIOR ALTERATION SHALL BEAR THE ATTRIBUTABLE COSTS.THE GENERAL CONTRACTOR SHALL GO-03B INTERIOR'S SCOPE OF WORK ITEMIZED • BUILDING EXTERIOR FINISH. ONLY+ WINDOW PROMPTLY NOTIFY THE DESIGNER IN WRITING OF ANY KNOWN CLIMATE FENESTRATION SKYLIGHT CEILING wooR NAB FLOOR BASEMENT sub svnce INTERIOR UNIT 1:NO INTERIOR ALTERATIONS. ALTERATIONS INCONSISTENCIES IN THE CONTRACT DOCUMENTS WITH SUCH GO-04A ZONING DEMOLITION NORTH&EAST FACADE ZONE U-FACTOR U-FACTOR R-VALUE F R VP DELL R WALL R-VALUE R VALUE R V VALUE wALL INTERIOR UNIT 2:ALTERATIONS TO EXISTING GOVERNMENTAL LAWS,RULES AND REGULATIONS. MODIFICATIONS R-VALUE GO-04B ZONING DEMOLITION SOUTH&WEST FACADE0 5 RESIDENTIAL BUILDING(NON LOAD BEARING). E. THESE DOCUMENTS ARE INTENDED TO MATERIALS,EQUIPMENT,AND 7 0.28 0.55 as 213+10 1s/z1 Sae 1s/1s` 10,aed 1s/1s` SITE EXISTING RESIDENCE EXISTING RESIDENCE MODIFICATIONS • 13+10" SERVICES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN.IT IS GO-04C ZONING PROPOSED NORTH&EAST FACADE ROOF OVERHANG: NO CHANGES THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF MODIFICATIONS • TABLE FOOTNOTES: UTILITY LOCATIONS: NO CHANGES TO EXISTING ISSUE THE DESIGNER ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION GO-04D ZONING PROPOSED SOUTH&WEST FACADE RREMP: NO CHANGES NO. REVISION DESCRIPTION DATE ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS;IT IS THEa C."15/19"MEANS R-15 CONTINUOUS INSULATED SHEATHING ON THE INTERIOR OR EXTERIOR OF 3 RESPONSIBILITY OF THE DESIGNER TO PROVIDE DETAILS AND/OR MODIFICATIONS THE HOME OR R-19 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL."15/19" FAR/UNIT 1(LOWER LEVEL): NO CHANGES TO EXISTING 3 DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED BY EXISTING GO-04E EXISTING PHOTOS AND PROPOSED FACADE SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE FAR/UNIT 2(UPPER LEVEL): NO CHANGES TO EXISTING I1 'ISSUE FOR PERMIT 105/24/2021 1 CONDITIONS OR WHERE IT IS NOT DETAILED IN THE DOCUMENTS. MODIFICATIONS BASEMENT WALL PLUS R-5 CONTINUOUS INSULATED SHEATHING ON THE INTERIOR OR GO-06 GENERAL NOTES • EXTERIOR OF THE HOME."10/13"MEANS R-10 CONTINUOUS INSULATED SHEATHING ON THE F. DRAWINGS AND SPECIFICATIONS DESCRIBES THE GENERAL SCOPE OF THE • INTERIOR OR EXTERIOR OF THE HOME OR R-13 CAVITY INSULATION AT THE INTERIOR OF THE INTERIOR(UNIT ALTERATIONS: BATHROOMS,BEDROOMS&KTCHEN PROJECT AND DESIGN CONCEPT IN TERMS OF THE INTERIOR DESIGN, BASEMENT WALL. 2/UPPER LEVEL) MECHANICAL,ELECTRICAL,AND PLUMBING SYSTEMS.THESE DOCUMENTS ID-00.1 DEMOLITION PLAN UNIT 1/LOWER LEVE&UNIT 2/ D.R-5 SHALL BE ADDED TO THE REQUIRED SLAB EDGE R-VALUES FOR HEATED SLABS. LOAD BEARING: REFER TO STRUCTURAL DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL OF THE WORK REQUIRED UPPER LEVEL INSULATION DEPTH SHALL BE THE DEPTH OF THE FOOTING OR 2 FEET,WHICHEVER IS LESS IN NON LOAD BEARING: PARTITIONS IN BATHROOMS,BEDROOMS, FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF ID-00.2 DEMOLITION CEILING PLAN UNIT 2/UPPER LEVEL • ZONES 1 THROUGH 3 FOR HEATED SLABS. CLOSETS THE CONTRACT.ON THE BASIS OF THE SCOPE INDICATED,DESCRIBED OR INFERRED,THE GENERAL CONTRACTOR SHALL DETERMINE AND INCLUDE IN ID-01.1 FLOOR PLAN • G.OR INSULATION SUFFICIENT TO FILL THE FRAMING CAVITY,R-19 MINIMUM. CEILINGS ALTERATIONS: BATHROOMS THE PROPOSALS ALL ITEMS NECESSARY TO PROVIDE THE PROPER ID-01.2 RCP&POWER/DATA FLOOR PLANS • H.THE FIRST VALUE IS CAVITY INSULATION,THE SECOND VALUE IS CONTINUOUS INSULATION, ELECTRICAL: OUTLETS AND DIMMERS FOR NEW LAYOUT, EXECUTION AND COMPLETION OF THE WORK.ALL DIMENSIONS SHALL BE ID-01.3 FINISH&FURNITURE FLOOR PLANS • SO"13+5„MEANS R-13 CAVITY INSULATION PLUS R-5 CONTINUOUS INSULATION. RELOCATION OF EXISTING ELECTRICAL PANEL FIELD VERIFIED PRIOR TO CONSTRUCTION AND/OR FABRICATION. ID-02.3 INTERIOR ELEVATIONS LIGHTING: LIGHTING:PER ENERGY CODE HIGH I.THE SECOND R-VALUE APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIOR EFFICIENCY IN DWELLING UNITS(2015 IECC G. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THESE SPECIFIED OR ID-02.4 KITCHEN ENLARGED PLAN&ELEVATIONS OF THE MASS WALL. EFFICIENCY CALLED OUT BY TRADE NAME IN THESE DOCUMENTS SHALL BE PRESENTED ID-02.5 RESTRM 1 ENLARGED PLAN&ELEVATIONS R404.1&C405.1) 2 TO THE DESIGNER FOR APPROVAL.THE CONTRACTOR SHALL SUBMIT ID-02.6 RESTRM 2 ENLARGED PLANS&ELEVATIONS PLUMBING: REPLACEMENT AND NEW LAYOUT. NO NEW 2 SAMPLES WHEN REQUIRED BY THE DESIGNER,AND ALL SUCH SAMPLES CONNECTIONS ADDED SHALL BE APPROVED BY THE DESIGNER IN WRITING BEFORE THE WORK IS ID-03.1 DETAILS • PERFORMED.WORK MUST CONFORM TO THE APPROVED SAMPLES;ANY KITCHEN: NEW LAYOUT,NEW APPLIANCES,NEW CASEWORK WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED PLANNING APPROVALS WITH WORK,WHICH CONFORMS AT THE GENERAL CONTRACTOR'S EXPENSE. FINISHES: NEW CASEWORK,TILE,NEW FLOORING SUBCONTRACTORS SHALL SUBMIT REQUESTS AND SAMPLES FOR APPROVAL FIREPLACE REPLACEMENT OF EXISTING FIREPLACE FOR THROUGH THE GENERAL CONTRACTOR WHEN WORK IS LET THROUGH HIM. FIRE CODE NOTES BUIDING CODE INFORMATION NEW H. SHOP DRAWINGS SHALL BE SUBMITTED TO THE DESIGNER AND A. FIRE SPRINKLERS AS ADOPTED BY ORDINANCE 31,2011:AUTOMATIC CODE EDITIONS 2015 INTERNATIONAL BUILDING CODE STRUCTURAL ENGINEER,FOR HER/HIS APPROVAL WHERE CALLED FOR FIRE SPRINLERS ARE REQUIRED IN ALL STRUCTURES 5,000 SQUARE EXTERIOR WINDOWS: NEW WINDOWS FEET OR GREATER AS DEFINED BY FIRE AREA AND IN STRUCTURES 2 ANYWHERE IN THESE DOCUMENTS.APPROVAL SHALL BE MADE BY THE 2015 INTERNATIONAL RESIDENTIAL CODE SIDING: NEW STANDING SEAM METAL WALL AND WD DESIGNER BEFORE WORK IS BEGUN,AND WORK SHALL CONFORM TO THE STORIES OR MORE IN HEIGHT AND IN STRUCTURES CONTAINING 4 OR 2015 INTERNATIONAL PLUMBING CODE BOARD&WD BATTENS OVER EXISTING SHEET TITLE APPROVED SHOP DRAWINGS,SUBJECT TO REPLACEMENT AS REQUIRED MORE DWELLINGS. 2015 INTERNATIONAL MECHANICAL CODE FACADE FOR SAMPLES IN PARAGRAPH G,ABOVE. B. CARBON MONOXIDE DETECTORS AS ADOPTED BT CITY ORDINANCE:ALL 2015 INTERNATIONAL FUEL GAS CODE LIGHTING: REPLACE SCONCES(DARK SKY COMPLIANCE COVER SHEET I. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE GENERAL OWNERS OF EXISTING RESIDENTIAL OCCUPANCIES SHALL COME INTO 2015 INTERNATIONAL FIRE CODE TYPE) CONTRACTOR WHEN THERE IS NEED OF AN INSPECTION AS REQUIRED BY COMPLIANCE WITH THE REQUIREMENTS OF CHAPTER 8.15 CARBON 2015 INTERNATIONAL EXISTING BUILDING CODE ROOF: EXISTING TO REMAIN-ADD SNOW MELT& THE UNIFORM BUILDING CODE OR BY ANY LOCAL CODE OR ORDINANCE MONOXIDE DETECTORS.THE ORDINANCE BECAME EFFECTIVE MARCH 2, 2017 NATIONAL ELECTRIC CODE GUTTERS 1 J. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND 2009 AND APPLIES TO ALL EXISTING,NEW AND ALTERED DWELLINGS. 2015 INTERNATIONAL ENERGY CONSERVATION CODE GARAGE: NO CHANGES 1 CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION;FOR C. CODE EDITIONS:2015 IBC, 2015 IRC,2015 MC,2015 IPC FIRE SPRINKLER _X NO _YES NFPA Ordinance 31, DECK&STAIRS: EXISTING TO REMAIN.REPLACEMENT OF COMPLIANCE WITH THE FEDERAL AND STATE O.S.H.A.REGULATIONS;AND FIRE SPRINKLER SYSTEMS INSTALLED YES X NO SYSTEM INSTALLED 2011 (Per EXISTING HANDRAIL SHEET NUMBER FOR THE OWNER. NFPA SPRINKLERED PER ORDINANCE 31,2011 ) SCREEN AT LEVEL 1 REPLACEMENT OF EXISTING WOOD SCREEN K. ASBESTOS-THE DESIGNER,AND DESIGN TEAM SHALL NOT BE LIABLE FOR TYPE OF CONSTRUCTION:WOOD FRAMED TYPE OF WOOD FRAME C w�, ANY ISSUE REGARDING ASBESTOS. **REFER TO SHEET G-02 FOR FIRE AREA DIAGRAM CONSTRUCTION LAUNDRY RM&MECHANICAL FOR NEW PERFORATED METAL SCREEN EIVEt/ROOM: G 0 0 0/05/2022 A IB IC 1 D IE 1F IG IH IJ 02020 MATTER PLANNINd4 DESIGN BUILDING G- ARTMENT A I B I C I D I E I F I G I H I 3 FAR&FIRE PLAN LEGEND EXISTING OR NIC PARTITION EXISTING OR NIC PARTITION MATTER NEW OR NEW PARTITION PLANNING 7 •,,• FIRE AREA BOUNDARY 7 +IDESIGN EXISTING INTERIOR FIRE FLOOR AREA AT J NIC(NOT IN CONTRACT)FLOOR PLAN E=j EXISTING INTERIOR FIRE FLOOR AREA AT PROPOSED FLOOR PLAN r 1 EXISTING EXTERIOR/OVERHANG I. —J FIRE FLOOR AREA — NCH DESIGN,LLC DBA ® MATTER PLANNING+DESIGN LLC HARDWIRED CARBON MONOXIDE/SMOKE 299 MILWAUKEE ST STE 206 DENVER,CO 80206 DETECTOR SUGGESTED PLACEMENT 970-379-5401 1 tterinteria m s.co BUSINESS LICENSE 12685 PROJECT TEAM FIRE AREA NOTES NOELLE HERNANDEZ 6 FIRE AREA CONDITIONS ARE EXISTING TO REMAIN. 6 NOELLE@MATTERINTERIORS.COM NO NEW FLOOR OR FIRE AREA,EXISTING FIRE AREA IS LESS THAN SORAYA GALLEGO 5,000 SF AT(3,544 SF): SORAYA@MATTERINTERIORS.COM -LOWER LEVEL EXISTING FIRE AREA: 1,455 SF NICOLE STEWART -LOWER LEVEL EXISTING DECK OVERHANG: 353 SF NICOLE@MATTERINTERIORS.COM -UPPER LEVEL EXISTING FIRE AREA: 1,355 SF -UPPER LEVEL ROOF OVERHANG AREA: 381 SF TOTAL: 3,544 SF -NO EXISTING FIRE SPRINKLER SYSTEM -SUGGESTED PLACEMENT FOR CARBON MONOXIDE AND SMOKE NOTES DETECTORS EXISTING OR NEW WHERE INDICATED CEILING S/C-REFER TO FIRE INSPECTOR FOR FINAL PLACEMENT. DRAWINGS AND SPECIFICATIONS DESCRIBES THE GENERAL SCOPE OF THE PROJECT AND DESIGN CONCEPT IN TERMS OF THE INTERIOR DESIGN, ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND ILLUSTRATE AND CALCULATE FIRE AREA AS DEFINED BY 2015 IBC PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT SECTION 902.IF THE FIRE AREA IS GREATER THAN WORK REQUI EDFORTHE ULLPERFARMANTEE 5 5000SQFT,A FIRE SPRINKLER SYSTEM IS REQUIRED PER ORDINANCE 5 WORK REQUIRED FORTHEMENOF THE AND 31,2011. COMPLETION OF THE REQUIREMENTS OF THE CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, DESCRIBED OR INFERRED,THE CONTRACTOR SHALL FIRE AREA.THE AGGREGATE FLOOR AREA ENCLOSED AND BOUNDED DETERMINE AND INCLUDE IN THE PROPOSALS ALL BY FIRE WALLS,FIRE BARRIERS,EXTERIOR WALLS OR HORIZONTAL ITEMS NECESSARY AND COMPLETION PROVIDETHET PROPERWORK. ASSEMBLIES OF A BUILDING.AREAS OF THE BUILDING NOT PROVIDED EXECUTION AND OF THE WORK. WITH SURROUNDING WALLS SHALL BE INCLUDED IN THE FIRE AREA IF GENERAL NOTES: SUCH AREAS ARE INCLUDED WITHIN THE HORIZONTAL PROJECTION OF THE ROOF OR FLOOR NEXT ABOVE. 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION AND/OR FABRICATION. ❑ CARBON MONOXIDE AND SMOKE DETECTOR LOCATIONS(ASPEN MUNICIPAL CODE CH 8.15) PROJECT 729 W FRANCIS ST ASPEN, CO, 81611 4 4 Al0 CC—) 1 1 �� - - -+�1 1- PROJECT TYPE ( I I l'''''1/777f'r EXISTING2'-0" INTERIOR ALTERATION _ � IROOFOVERHANG ONLY} WINDOW CI ALTERATIONS -- I WirrrY ,; )A_i,, Imo' ,w 1 ISSUE ,� —_ ' 6 oP' 9�� - rI f Na REVISION DESCRIPTION DATE 3 i cI 3 �� I1 I ISSUE FOR PERMIT 105/24/2021 irriI I w ,// ,- ` ,I �/ �� ��A. - .1 � �/ I I- EXISTING RH y A ROOF OVERHANG 0 ,� • 4 4 j ® L ( V— I�l` I // ///• ni� LI I L, EXISTING BUILDING• Pr': r EXISTING ROOF EXISTING BUILDING 'I 'I FIRE AREA' OVERHANG FIRE � FIRE AREA 1,355 SF I 11 1,455 SF/ / AREA 381 SF-4 F 2 �� I e ® 11 2 CO .EXISTING DECK ' EXISTING OVERHANG y�� _ I D ` OVERHANG TO �= FIRE AREA 1•' — y J EXISTING 4'-0" L —---------—--� DN PLANNING APPROVALS ROOF OVERHANG ...----- REMAIN EXISTING DECK 11 353 SF ill - HI AREA 408 SF L___- - __ -..-J r 4 r - = k - - M1- EXISTING BUILDING FIRE AREA: 1,455 SF EXISTING BUILDING FIRE AREA: 1,355 SF SHEET TITLE EXISTING OVERHANG FIRE AREA: 353 SFL EXISTING OVERHANG FIRE AREA: 381 SF TOTAL FIRE AREA(LOWER LEVEL): 1,808 SF TOTAL FIRE AREA(UPPER LEVEL): 1,736 SF FIRE AND FAR PLAN NO CHANGE ON FIRE AREA DP NO CHANGE ON FIRE AREA DIAGRAMS 1 1 1 D FIRE AREA_ UNIT 1/ LOWER LEVEL FLOOR PLAN 5D FIRE AREA_ UNIT 2/ UPPER LEVEL FLOOR PLAN SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" SHEET NUMBER GO-O /05/2022 A IB 1C D IE 1F IG 1H IJ ,D2020 MATTER PLANNING\+DESIGN BUILDING L ARTMENT A I B I C D I E I F I G I H 1 3 EXTERIOR SCOPE OF WORK MATT E R EXTERIOR WORK TYPEIF .INME C EL-01 CUT SHEET PLANNING 7 MARK TYPE DESCRIPTION 1■1■1■1■1■1■1■1■1■1■1■ PITCH SINGLE WALL SCONCE "I_TECH LIGHTING +I D E S I G N - 111111111111111111tl11 EXT 1 NEW STANDING SEAM METAL WALL AT EAST AND WEST FACADE.INSTALL OVER EXISTING EXTERIOR WALL -�I1_11_1_1_1-�_l-i 11119111111111111111111111111111tl1 ] i_ EXT 2 NEW WOOD BOARD&WOOD BATTENS AT NORTH AND SOUTH FACADE.INSTALL OVER EXISTING EXTERIOR WALL 0■■■■■■■ 1111111111111111111111 EXT 3 NEW EXTERIOR WALL INFILL WHERE WINDOWS ARE REMOVED OR REPLACED. INFILL ROOF AT 11111111111 DEMOLISHED 1111111111111111111111IIIIIIIIItlI EXT 4 WINDOWS NEW THROUGHOUTO°I•I•"e"""•I••r°"• "•I^•••m•"I•. SKYLIGHT EXT 5 EXTERIOR DOORS NEW AS INDICATED IN PLAN 011111111111111111101s s�mo „"^.,e"•,. 11111111111111111111tl11 mwn-,•=, m.uv=•eea•ex•n«MryK.„:", _ NCH DESIGN,LLC DBA EXT 6 EXTERIOR WALL OPENING AT NEW WINDOWS/DOORS LOCATIONS AND AT FIREPLACE VENTILATION 1 1 1 1 1 1 1 1 1 1 1 1 c."wm•"MwE•",r.m"""e• r,"NN". MATTER PLANNING+DESIGN LLC EXT 7 FLASHING(AT GROUND FLOOR) NEW THROUGHOUT -- 1LLLLLIy- 11111d1111I11111I111tl11 299 MILWAUKEE ST STE 206 DENVER,CO 80206 '2� 1■-1 1-■1 1 1 SPECIFICATIONS 970-379-5401 I www.matterinteriors.com EXT 8 EXISTING STUCCO TO BE REMOVED THROUGHOUT i1■'1■1'1'1■ 1 111111111111111111III BUSINESS LICENSE 12685 EXT 9 EXISTING WOOD SIDING TO BE REMOVED THROUGHOUT I 101 I111III111I111IIIItl11 „- EXT 10 EXISTING ROOF ASSEMBLY TO REMAIN AND TO BE REPAIRED AS REQUIRED 1 111tl11 M,M "" PROJECT TEAM EXT 11 EXISTING ROOF STRUCTURE TO REMAIN AND TO BE REPAIRED AS REQUIRED.PREP FOR NEW FINISH 111101 a.,".,.b. A A tl I „,-,.°° „ ° '°° NOELLE HERNANDEZ 6 EXT 12 GUTTERS TO REMAIN AND TO BE REPAIRED AS REQUIRED.PREP FOR NEW FINISH 1 1111101 - ""= SI 6 NOELLE@MATTERINTERIORS.COM EXT 13 EXISTING WOOD DECK TO REMAIN AND TO BE REPAIRED AS REQUIRED.PREP FOR NEW FINISH 111111111111 ,°...,.„m ,b-,MT.„,„- 1 1111111101 SORAYA GALLEGO EXT 14 EXISTING HANDRAIL STRUCTURE TO REMAIN AND TO BE REPAIRED AS REQUIRED 1 1111111111111111tl11 "°°^" "" SORAYA@MATTERINTERIORS.COM 11111111111 EXT 15 HANDRAIL BALAUSTER EXISTING TO BE REMOVED FOR REPLACEMENT 11111111111111111111111 `;„.„ - A A NICOLE STEWART EXT 16 EXISTING STAIRS TO REMAIN AND TO BE REPAIRED AS REQUIRED 4 1 111111111111111111tl 1 NICOLE@MATTERINTERIORS.COM �� 1111111111111111111tl11 u,„•..,",E,. "". ... EXT 17 LIGHTING/SCONCES NEW THROUGHOUT 111111111111111111111 1 EXT 18 EXISTING SKYLITE TO REMAIN AND TO BE REPAIRED AS REQUIRED IIIIIIIIIItliI „-,'�",-- " EXT 19 EXISTING WOOD SCREEN TO BE DEMOLISHED FOR REPLACEMENT(AT EXISTING MECHANICAL ROOM) 11111111111111111111111 „„,�M, _ 1 1 111 11111111111tl1■ EXT 20 NEW PERFORATED METAL SCREEN NEW(AT EXISTING LAUNDRY AND MECHANICAL ROOM/LOWER LEVEL) 1 tl 1 1 1 1 1 1 1 1 1111tl1111� a,,,, •�-v, z.s I tl l l EXISTING ROOF TO REMAIN 111111 s Ki _64mm NOTES EXT 21 METAL FRAME NEW AROUND NEW WINDOWS AND EXTERIOR DOORS 11011111111111111111111111111 "•�" - Ins -- EXT 22 METAL FRAME CANOPY NEW AT LOWER LEVEL(WEST AND EAST FACADE) 11tltl111111111111111111111111111111111111111111 .A�> .. `a _. s• , "9 a DRAWINGS AND SPECIFICATIONS DESCRIBES THE 11N1111111111111111111111111111111111111111111 1z'm"'sa"." ao mm GENERAL SCOPE OF THE PROJECT AND DESIGN EXT 23 FLASHING(ROOF) NEW THROUGHOUT 111111111111111111111111111111111111111111111111 Pitch Single CONCEPT INTER MS OF THE INTERIOR DESIGN, EXT 24 INFILL OPENING AT REMOVED THERMAL BARRIER WITH NOMINAL 2X4 TIMBER AND INSULATION.MATCH ''''' ''1'1'1'1',I111111111111111111111 I ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND SKYLIGHT CONSTRUCTION ASSEMBLY MATERIALS AND FINIHSES ,II1I1I1I1I1I1I1I1I1 ORDERING INFORMATION PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL OF THE WALL FINISH 20 PAINT FOR EXSTING HANDRAIL STRUCTURE TO REMAIN 0 411111111111111111 _ _ WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 WALL FINISH 21 PAINT FOR EXTERIOR GUTTER aJAIIIIIIIIIIIIIIII ,�"„ e 5 COMPLETION THE BASISREQUIREMENTSFT THE CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, WALL FINISH 22 PAINT/STAINED FOR EXTERIOR EXPOSED WOOD STRUCTURE d:111111111111171■11111ii111111111111111111111 " '®a" �' DESCRIBED OR INFERRED,THE CONTRACTOR SHALL DETERMINE AND INCLUDE IN THE PROPOSALS ALL WALL FINISH 23 PAINT/STAINED FOR EXISTING STAIRS ITEMS NECESSARY TO PROVIDE THE PROPER WEXT1 PARTITION TYPE EXTERIOR PARTITION TO MATCH EXISTING ASSEMBLY. kechq.u.am EXECUTION AND COMPLETION OF THE WORK. ROOF EXISTING TO REMAIN. GENERAL NOTES: DEMO(1)EXISTING SKLYLIGHT, INFILL 15 SF.THERMAL BARRIER WITH NOMINAL 2X4 TIMBER AND INSULATION.MATCH CONSTRUCTION 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO EXTERIOR DOOR SCHEDULE-NEW SCOPE OF WORK- ASSEMBLY MATERIALS AND FINIHSES. EXTERIOR LIGHT FIXTURE SCOPE PLAN LEGEND _ CONSTRUCTION AND/OR FABRICATION. DOOR SIZE SO FT 772, NOT IN CONTRACT (R) NEW LIGHT FIXTURE TO BE LEVEL ELEV SIDE MARK DOOR TYPE ROOM NAME R.O.WIDTH R.O.HEIGHT DOOR U-VALUE MANUF F EXISTING ROOF SCOPE OF WORK INSTALLED AT EXISTING LOCATION PROJECT EXISTING OR NIC PARTITION LOWER LVL EAST LLDR-04 SINGLE SWING LL-MUD RM 3'-0 3/8" 6'-11 1/4" 21 0.29 KOLBE SCALE: 1/8"=1'-0" EXISTING TO REMAIN (N) NEW LOCATION 729 W FRAN C I S ST LOWER LVL SOUTH LLDR-02 SINGLE SWING LL-LIVING RM 8'-0 1/4" 7'-11 3/4" 60 0.26 KOLBE IZI NEW EXTERIOR LIGHT FIXTURE LOWER LVL SOUTH LLDR-01 SLIDING LL-DINING 8'-01/4" 7'-113/4" 60 0.26 KOLBE NEW OR NEW PARTITION SYMBOL ASPEN, CO, 81611 LOWER LVL WEST LLDR-03 SLIDING LL-LIVING RM 3'-0 3/8" 6'-11 1/4" 21 0.29 KOLBE 4 UPPER LVL SOUTH UPDR-03 SINGLE SWING VESTIBULE 3'-0 3/8" 6'-11 1/4" 21 0.29 KOLBE 4 UPPER LVL SOUTH UPDR-02 SLIDING EXISTING DECK 8'-0 1/4" 7'-6" 60 0.26 KOLBE UPPER LVL SOUTH UPDR-01 SLIDING EXISTING DECK 8'-0 1/4" 7'-6" 60 0.26 KOLBE (R) , 3 C q/1 Al EL-01T- - - - - 'T - PROJECT TYPE -- EXTERIOR WINDOW SCHEDULE NEW SCOPE OF WO- M. Or 0 II' (R)1III INTERIOR ALTERATION ROUGH ROUGH ��% ONLY+ WINDOW LEVEL ELEV SIDE MARK TYPE ROOM NAME HGTH. WIDTH SQ FT U-VALUE MANUF. NOTES �I ALTERATIONS LOWER LVL EAST LLW-07 SLIDING LL-BEDRM 1 3'-6 1/4" 6'-01/4" 21 0.25 KOLBE EGRESS LOWER LVL EAST LLW-08 AWNING LL-BATH 1 2'-0 1/4" 3'-6 1/4" 7 0.25 KOLBE 0 11 28 0 441" LOWER LVL NORTH LLW-05 SLIDING LL-BEDRM 2 3'-6 1/4" 5'-0 1/4" 18 0.26 KOLBE EGRESS NEW EXTERIOR ® Y I / ISSUE LIGHT FIXTURE TO word, - li NEW EXTERIOR (2 LOWER LVL NORTH LLW-06 SLIDING LL-BEDRM 1 3'-6 1/4" 5'-0 1/4" 18 0.26 KOLBE EGRESS BE INSTALLED AT LIGHT FIXTURE TO NO. REVISION DESCRIPTION DATE ���r BE INSTALLED AT 3 LOWER LVL NORTH LLW-09 AWNING LL-LAUNDRY 4'-0 1/4" 3'-0 1/4" 12 0.25 KOLBE EXISTING LOCATION _' - EXISTING LOCATION I 48 © �� / _ 3 LOWER LVL WEST LLW-01 CASEMENT LL-LIVING RM 4'-0 1/4" 4'-6 1/4" 18 0.26 KOLBE ,�A / LOWER LVL WEST LLW-02 SLIDING LL-BEDRM 3 4'-0 1/4" 4'-0 1/4" 16 0.26 KOLBE EGRESS j1r �� Ip LOWER LVL WEST LLW-03 AWNING LL-BATH 2 2'-0 1/4" 3'-6 1/4" 7 0.25 KOLBE 01 '� f - LOWER LVL WEST LLW-04 SLIDING LL-BEDRM 2 3'-6 1/4" 6'-0 1/4" 21 0.25 KOLBE EGRESS 4 62 �4 ��I (R) � V 11- EL-GI UPPERLVL EAST UPW-10 SLIDING MASTER 4-01/4" 6'-01/4" 24 0.26 KOLBE EGRESS i '' - I_ BEDROOM /,://, 'UPPER LVL EAST UPW-11 FIXED BATHRM 1 1'-0 1/4" 5'-6 1/4" 5.5 0.25 KOLBE ELA1 II� yL 7 UPPER LVL EAST UPW-12 CASEMENT TOILET RM1 6'-0 1/4" 2'-0 1/4" 12 0.24 KOLBE (R) IC:iUPPER LVL EAST UPW-13 CASEMENT VESTIBULE 6'-0 1/4" 2'-0 1/4" 12 0.24 KOLBE 115 24. UPPER LVL NORTH UPW-08A AWNING BEDROOM 1 1'-6 1/4" 4'-0" 63 5 0.25 KOLBE ■ IIUPPER LVL NORTH UPW-08B AWNING BEDROOM 1 1'-6 1/4" 4'-0" 6 0.25 KOLBE , 2 11 UPPER LVL NORTH UPW-09A AWNING MASTER 1'-6 1/4" 4'-0" 6 0.25 KOLBE BEDROOM - 5A , j I 1. __ UPPER LVL NORTH UPW-09B AWNING MASTER 1'-6 1/4" 4'-0" 6 0.25 KOLBE r J PLANNING APPROVALS BEDROOM EL-o1 EL-) EL-01 J L _(�_ _ DN 24 NEW EXTERIOR (N) (R) I - _ ■�■� LIGHT FIXTURE I r - - M� UPPER LVL WEST LLW-03 AWNING LIVING RM 2'-0 1/4" 3'-6 1/4" 6 0.26 KOLBE (NEW LOCATION) UPPER LVL WEST UPW-03 AWNING LIVING RM 2'-0 1/4" 3'-0 1/4" 6 0.26 KOLBE a_ 1 I_ H NEW EXTERIOR LIGHT I I I NEW EXTERIOR UPPER LVL WEST UPW-05 SLIDING BEDROOM2 4'-6" 4'-6" 20.25 0.31 KOLBE EGRESS FIXTURE TO BE == INSTALLED AT LIGHT FIXURE UPPER LVL WEST UPW-06 FIXED BATHRM 2 1'-0 1/4" 4'-0 1/4" 4 0.25 KOLBE I (NEW LOCATION) M� EXISTING LOCATION I SHEET TITLE UPPER LVL WEST UPW-07 SLIDING BEDROOM 1 4'-6" 4'-6" 20.25 0.31 KOLBE EGRESS __'� m� 56.5 �� EXTERIOR SCOPE I.. OF WORK ITEMIZED IIIPt LIGHTING FIXTURE SCHEDULE-EXTERIOR EXTERIOR PROPOSED UP EXTERIOR PROPOSED TAG MANUFACTURER TYPE/MODEL FINISH LAMP 1 F LIGHTING DIAGRAM LOWER LEVEL 1 H LIGHTING DIAGRAM UPPER LEVEL SHEET NUMBER EL-01 Tech Lighting WALL SCONCE/PITCH SINGLE METAL BLACK LED _ OUTDOOR WALL NORTH G 0 0 3cRE22D A I B 1 C I D I E I F I G I H I J ®2020 MATTER PLANNINAIS 1B1 N BUILDING DEPARTMENT A I B I C I D I E I F I G I H I 3 INTERIOR SCOPE OF WORK MATT E R 7 APPLIANCES SCHEDULE INTERIOR DOOR SCHEDULE-NEW SCOPE OF WORK- CEILING SCHEDULE PLANNING MARK ROOM NOTES DOOR SIZE MARK TYPE NOTES +I D E S I G N AP.1 KITCHEN KITCHEN PACKAGE:NEW REFRIGERATOR,DISHWASHER, MARK LOCATION WIDTH HEIGHT TYPE HARDWARE CLG-1 GYP BORAD CEILING AT BATHROOMS FINISH:LEVEL 4/PAINTED RANGE,OVEN,MICROWAVEM EXHAUST HOOD 205 LAUNDRY CL 5'-0" 7'-0" PAIR BIFOLD DOOR HD.3 CLG-2 GYP BOARD CEILING FINISH:LEVEL 4/PAINTED AP.2 LAUNDRY CLOSET NEW WASHER&DRYER 206 COAT CL 4'-6" 6'-8" PAIR BIFOLD DOOR HD.3 CLG-3 GYP BOARD CEILING OVER EXISTING FINISH:LEVEL 4/PAINTED AP.3 BATHROOM 1&2 EXHAUST FAN 207 CORRIDOR 3'-0" 6'-8" SINGLE SWING DOOR HD.1 WOOD CEILING 208 BATHRM 2 2'-6" 6'-8" SINGLE SWING DOOR HD.1 CLG-4 GYP BORAD CEILING AT BATHROOMS FINISH:TILE - 209 CORRIDOR 3'-0" 6'-8" SINGLE SWING DOOR HD.1 (SHOWER) - NCH DESIGN,LLC DBA MATTER PLANNING+DESIGN LLC lir CONSTRUCTION TYPES SCHEDULE 210 CORRIDOR 6'-8" SINGLE SWING DOOR HD.1 299MILWAUKEESTSTE206DENVER,C080206 211 BATHRM 1 2'-7" 7'-0" POCKET DOOR HD.2 970-379-5401 www.ma erin eriE TYPE DESCRIPTION INTERIOR LIGHTING FIXTURE SCHEDULE BUSINESS LICENSE 12685 GLD-01 BTHRM 1 2'-6" 8'-0" GLASS SWING DOOR AT BATHROOM 1/ HD.4 PARTITION W3 TYPICAL 4 3/4"THICK INTERIOR PARTITION WITH BATT INSULATION SHOWER SHOWER GL.1 TAG ROOM TYPE NOTES PROJECT TEAM PARTITION W4 6 3/4"THICK INTERIOR PARTITION WITH BATT INSULATION GLD-03 BATHRM 2 2'-3" 6'-8" GLASS SWING DOOR AT BATHROOM 2/ HD.6 LT-01 TYP THROUGHOUT RECESSED LIGHT FIXTURE PERMANENT PARTITION W5 4 5/8"THICK INTERIOR PARTITION WITH INSULATION BATT AT AT TUB GL.3 LT-03 LAUNDRY AND COAT CLOSET WALL MOUNTED ABOVE DOOR FRAME NON PERMANENT NOELLE HERNANDEZ 6 SHOWER LOCATIONS LT-04 BATHROOM 1 WALL SCONCE AT VANITY SINK NON PERMANENT 6 NOELLE@MATTERINTERIORS.COM PARTITION W6 6 5/8"THICK INTERIOR PARTITION WITH BATT INSULATION AT LT-05 MASTER BEROOM WALL SCONCE NON PERMANENT SORAYAGALLEGO SHOWER LOCATIONS SORAYA@MATTERINTERIORS.COM INTERIOR DOOR HARDWARE SCHEDULE LT-06 BATHROOM 2 WALL SCONCE NON PERMANENT WATERPROOF NEW WATERPROOF FOR CURBLESS SHOWERS LT-07 SEE PLAN CEILING SURFACE MOUNTED 1 NON PERMANENT NICOLE STEWART INSULATION NEW FOR SOUND AT ALL WALLS MARK TYPE NOTESNICOLE@MATTERINTERIORS.COM LT-08A LIVING ROOM/SOFFIT CEILING SURFACE MOUNTED-TAPED LED NON PERMANENT PIPING REWORK FOR NEW LAYOUT WRAP PIPES HD.1 SINGLE SWING DOOR PACKAGE LEVER,ROSETTE,LOCK SET,CONCEALED HINGES, LT-08B KITCHEN/CABINETS CEILING SURFACE MOUNTED-TAPED LED NON PERMANENT DOOR AND FRAMES NEW THROUGHOUT FLOOR STOP LT-09 DINING ROOM DECORATIVE CEILING SURFACE MOUNTED NON PERMANENT HARDWARE NEW THROUGHOUT HD.2 POCKET DOOR PACKAGE TRACK PULLS WITH PRIVACY LATCH - APPLIANCES NEW THROUGHOUT HD.3 CLOSET BIFOLD DOOR PACKAGE LEVERS LATCH AND HINGES,PULL,DOOR STOP NOTES BLOCKING IN-WALL STEEL OR FIRE RATED WOOD HD.4 GLASS SWING DOOR SHOWER HINGES,KNOBS AND PULLS LT-01 CUT SHEET HD.5 GLASS SWING DOOR TOILET HINGES,KNOBS AND PULLS DRAWINGSAND SPECIFICATIONS DESCRIBES THE ¢ GENERAL SCOPE OF THE PROJECT AND DESIGN COMPARTMENT �pl�.� gst 3"Round Regressed Gimbal LED 7.5W CONCEPT IN TERMS OF THE INTERIOR DESIGN, HD.6 GLASS SWING DOOR AT TUB HINGES,KNOBS AND PULLS ` IFghts ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT HD.7 VANITY PACKAGE BATHROOM 1 PULLS : NECESSARILY INDICATE OR DESCRIBE ALL OF THE WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 MARK TYPE NOTES HD.8 VANITY PACKAGE BATHROOM 2 PULLS // ` Location: 5 COMPLETION OF THE REQUIREMENTS OF THE EL.1 OUTLETS FOR NEW LAYOUT HD.9 MILLWORK PACKAGE KITCHEN CABINET PULLS Y ` Cat Ory_ CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, DESCRIBED OR INFERRED,THE CONTRACTOR SHALL EL.2 APPLIANCE FOR NEW LAYOUT Now: DETERMINE AND INCLUDE IN THE PROPOSALS ALL EL.3 TV FOR NEW LAYOUT Type IC,Wet&Air-Tight ITEMS NECESSARY TO PROVIDE THE PROPER EL.4 THERMOSTAT FOR NEW LAYOUT DESCRIPTION SPECIFICATION EXECUTION AND COMPLETION OF THE WORK. INTERIOR WALL/SUFARCES FINISH TYPE 3'Round Regressed Gimbal LED I Sloped Ceilings,Highlighting Artwork GENERAL NOTES: EL.5 KITCHEN HOOD FOR NEW LAYOUT With Integed Driver In Connection Box Energy Used 7.5W EL.6 HOME NETWORK FOR NEW LAYOUT MARK TYPE LOCATION NOTES Gimbal Yet Air-Tight Without Housing Needed Color Temperature 2700 1 3000 1 3500 14000 15000 1 DTW 32 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO EL.7 RESTROOMS EXHAUST FANS FOR NEW LAYOUT PT.1 PAINT 1 WALLS,TYP THROUGHOUT,U.O.N. PREP FINISH TO LEVEL 5 TO RECEIVE Light Output 580 1 600 1 620 I 630 1 650 I 500 - CONSTRUCTION AND/OR FABRICATION. NEW PAINT FINISH FEATURE58BENEFITS Li Halogen aknt saw_ EL.8 DIMMERS FOR NEW LAYOUT 2 12°Deep-Instal Where Ceiling Space is Limited Beam Angle 38.or 15°with 20°tilt and 360°rotation EL.9 SWITCHES FOR NEW LAYOUT PT.2 PAINT 2 WALLS AT BATHROOMS 1&2 PREP FINISH TO LEVEL 5 TO RECEIVE Type IC Rated-No Housing Required CRI I 90+ PROJECT NEW PAINT FINISH Fast&Easy To Install-Save On Labor Default Driver input 120V AC Tdac Dimmable EL.10 ELECTRICAL PANEL RELOCATED Driver Inside Connection Box-No Junction Box Needed Optional D,wor Input 120V-347VAC 0-10V Dimmable EL.11 BATHROOM FANS FOR NEW LAYOUT PT.3 PAINT 3 CEILING AT BATHROOMS PREP FINISH TO LEVEL 4 TO RECEIVE 729 W FRANCIS ST CRI90+for TmeCobrRendedng uncbnBox WmCapadry Max5No12AWGor8No14AWG NEW PAINT FINISH Power Factor 0.95 ASPEN, CO, 81611 PT.4 PAINT 4 FOR EXISTING WOOD CEILING STAINED MOUNTING Approved Location Insulated Caen&Wet Locations .1 QUARTZ 1 AT BATHROOMS(COUNERTOP) Cut Hole In Ceiling And Snap Fixture In Opening IP Raring IP 54 QZ 4 With Attached Spring Clips AO-Tight Yee 4 INTERIOR GLAZING TYPES QZ.2 QUARTZ 2 AT KICTHEN(COUNTERTOP) Ceiling Clearance Required:312' _ Ambient Temperature -40°F(-40°C)to+104°F(+40°C) T. TILE 1 AT BATHROOMS 1&2 Projected Life 70%Light Output at 50,000 Fours MARK ROOM TYPE DIMENSIONS: ID31/4"OD41/4'Cut Out 31/4'to312" Certification 0ULus,Energy Star(except DTW),T24 T.2 TILE 2 AT FIREPLACE Warranty 10 Year Residential/5 Year Commercial GL.1 AT BATHROOM 1 GLASS PARTITION AT SHOWER PROJECT TYPE GL.2 AT BATHROOM 1 GLASS PARTITION AT TOILET T. TILE 3 AT KITCHEN 120VTRIAC Dimmable Optional 120V-34TV T.4 TILE 4l WALL AT BATHROOMS Driver Included Drive 0-10V Dimmable ENCLOSURE BASE -ff #LL- OrderSeparatetyas INTERIOR ALTERATION GL.3 AT BATHROOM 2 GLASS PARTITION AT TUB Cat L-LD0718T - GL.4 AT BATHROOM 1 MIRROR WB.1 WOOD BASE AT ALL WOOD FLOOR LOCATIONS tn� " ONLY+ WINDOW GL.5 AT BATHROOM 2 MIRROR I=1 ALTERATIONS GL.6 FOR REPLACEMENT AT EXISTING GLASS BALAUSTER i�1 I ACCESSORIES Sold Sop a.* EXTERIOR DECK&STAIR HANDRAIL INTERIOR FLOOR TYPES " " Low Vo age Extension Cables 6h-cat#IXCB.20ft-cat#ESC20 MARK ROOM DESCRIPTION AVAILABLE TRIMS Max 40 h Allowed.FT4/CMR rated ISSUE FLR.1 TYP.THROUGHOUT RADIANT HEAT SYSTEM fie` • Fbt Rough-In Fiats-Cat#RIP312 NO. I REVISION DESCRIPTION I DATE B PLUMBING COUNT FLR.2 TYP.THROUGHOUT,U.O.N. WOOD FLOOR .4 '" � Aell g FLR.3 AT BATHROOM 1 TILE FLOOR TYPE EXISTING NEW ADDED White Black Flanged Rate with Hanger Ban TOILETS 2 2 0 FLR.4 AT BATHROOM 2 TILE FLOOR ,-� -cat#FRP312 ORDERING GUIDE Example:LR03-30K-WH SHOWERS&SHOWER CONTROLS 1 1 0 CCT Trim nosh Beam Angle TUB,SHOWER AND CONTROLS 1 1 0 LRO3 -x0K xx - 2700K 27K -WH for38°leave blank COMPLIANCE VANITY FAUCET 2 3 +1 MILLWORK LEGEN l 3000K 30K -BK -15D spot 15" SINK 1 1 0 3500K 35K 0001M1 M Type IC SINK FAUCET 1 1 0 MARK ROOM DESCRIPTION 4000K 40K e47a#10 Air-nMM MW.1 KITCHEN PACKAGE REFER TO ELEVATIONS AND DETAILS 5000K 50K DTW 3K-2K 32K 38°Only Din to Warm 3K to 2K USA Patent#US 10,344,952 B2 1 Canada Patent#2.967,954 MW.2 LIVING ROOM/FIREPLACE REFER TO ELEVATIONS AND DETAILS MW.3a BATHROOM 1 VANITY Lotus LED Lights USA www.LotusLEDLights.com Lotus LED Lights CANADA MW.3b BATHROOM 2 VANITY 250 H Street#301,Blane WA 98230 to 360-200-5500 800-15355 24 Ave Box 200,Surrey BC V4A 2H9 tel 604-538-3090 Heinesport NJ,Naples FL,Dallas TX,Vancouver WA Della BC&Mississauga ON MARK ROOM DESCRIPTION MW.4a BEDROOM 1 FREE STANDING WARDROBE.REFER TO ELEVATIONS AND DTLS PL.1 BATHROOM 1&2 NEW TOILET MW.4b _BEDROOM 2 FREE STANDING WARDROBE.REFER TO ELEVATIONS AND DTLS 2 PL.2a BATHROOM 1&2 NEW UNDERMOUNT SINK MW.4c MASTER BEDROOM FREE STANDING WARDROBE.REFER TO ELEVATIONS AND DTLS 2 PL.2b BATHROOM 1&2 NEW FAUCET MW.5 ALL TRIM PACKAGE_PAINT EXISTING PL.3a BATHROOM 1&2 NEW SHOWER HEAD MW.6 COAT CLOSET SHELVES PL.3b BATHROOM 1&2 NEW SHOWER FLOOR DRAIN MW.7 LAUNDRY CLOSET SHELVES PLANNING APPROVALS PL.3e BATHROOM 1&2 NEW HANDSHOWER PL.3f BATHROOM 1&2 NEW SHOWER HOSE PL.4a BATHROOM 1&2 NEW WALL MOUNTED HOOKS PL.4b BATHROOM 1&2 NEW TOWEL BAR PL.4c BATHROOM 1&2 NEW TOILET PAPER HOLDER PL.5 KITCHEN NEW SINK SHEET TITLE PL.6a KITCHEN NEW FAUCET PL.6b KITCHEN NEW SAOP DISPENSER INTERIOR'S SCOPE PL.6c KITCHEN NEW FILTERED WATER TAP OF WORK ITEMIZED PL.7 BATHROOM 2 NEW TUB 1 1 SHEET NUMBER GO-O3B °'2 A I B I C I D I E I F I G I H I J 0 2020 MATTER PLANNINQIMN BUILDING DEPARTMENT A 1 B 1 C I D 1 E 1 F I G I H 1 3 DEMOLITION ELEVATIONS LEGEND WINDOW SCHEDULE DEMOLITION SCOPE OF WORK NORTH&EAST EXTERIOR DOOR SCHEDULE DEMOLITION SCOPE OF WORK NORTH&EAST EXISTING KEYNOTE LEGEND ELEVATION SIDE ROUGH ROUGH DOOR SIZE SQ FT TO BE DEMOLISHED D-31 HATCH AREA INDICATES:EXISTING WINDOW AND/OR WALL AREA TO BE LEVEL MARK HEIGHT WIDTH SQ FT LEVEL ELEV SIDE MARK WIDTH HEIGHT DOOR DEMOLISHED FOR NEW WIDNOW REPLACEMENT.REFER TO CONSTRUCTION MATT E R LOWER LVL EAST DW27 3'-0" 6'-4" 19 LOWER LVL EAST DD-02 3'-0" 6'-8" 20 El KEYNOTE PLANS AND ELEVATIONS FOR NEW SCOPE OF WORK,TYP. LOWER LVL EAST DW28 1'-3" 3'-0" 4 TAG D-32 HATCH AREA INDICATES:EXISTING WINDOW TO BE DEMOLISHIED.NO WINDOW PLANNING 7 LOWER LVL NORTH DW25 3'-4" 5'-0" 17 �) DOOR TAG REPLACEMNET AT THIS LOCATION.INFILL EXTERIOR WALL TO MATCH EXISTING 7 + D E S I G N LOWER LVL NORTH DW26 3'-4" 5'-0" 17 WALL ASSEMBLY. { LOWER LVL NORTH DW30 4'-0" 2'-10" 12 WINDOW D-33 HATCH AREA INDICATES:EXTERIOR WALL TO BE DEMOLISHED AS REQUIRED TAG FOR NEW WINDOW LOCATION 69 D-34 EXISTING DOOR TO BE DEMOLISHED FOR REPLACEMENT AT SAME LOCATION. UPPER LVL EAST DW8 3'-6" 3'-8" 13 DEMO WALL AREA FOR D-36 EXISTING LIGHT FIXTURE TO BE DEMOLISHED FOR REPLACEMENT. UPPER LVL EAST DW9 3'-6" 3'-8" 13 ///; NEW WINDOW LOCATION D-37 EXISTING WOOD SCREEN TO BE DEMOLISHED FOR REPLACEMENT. UPPER LVL EAST DW10 3'-0" 3'-0" 9 A 7, REP ACEM NW FOR D-38 EXISTING SKYLIGHT TO BE DEMOLISHED.EXISTING OPENING TO BE INFILLED — MATTER PLANNINGSI DESIGN LLC DBA UPPER LVL EAST DW11 3'-0" 4'-4" 13 AND TO MATCH EXISTING ROOF CONSTRUCTION. 299 MILWAUKEE ST STE 206 DENVER,CO 80206 UPPER LVL EAST DW12 4'-0" 4'-10" 16 ��� DEMO WINDOW FOR D-39 EXISTING EXTERIOR STUCCO TO BE ENTIRELY REMOVED,TYP.G.C.TO PREP 970-379-54011 www.matterinteriors.com UPPER LVL NORTH DW7 4'-0" 4'-6" 18 - - ' LOCATION AT WER LE WALL SURFACE AS REQUIRED FOR NEW FACADE FINISH. BUSINESS LICENSE 12685 LOCATION AT LOWER LEVEL 82 DEMO WINDOW.NO D-40 HATCH AREA INDICATES:EXISTING WINDOWS AT LOWER LEVEL TO BE PROJECT TEAM REPLACEMENT.INFILL DEMOLISHED FOR NEW WIDNOW REPLACEMENT AT SAME LOCATION AS EXTERIOR WALL EXISTING TO BE DEMOLISHED,UNLESS OTHERWISE NOTED. NOELLE HERNANDEZ EXISTING STUCCO TO D-41 EXISTING BALAUSTER TO BE REMOVED FOR REPLACEMENT.HANDRAIL NOELLE@MATTERINTERIORS.COM BE REMOVED STRUCTURE TO REMAIN.G.C.TO VERIFY EXISTING CONDITIONS AND REPAIR AS SORAYA GALLEGO REQUIRED.PREP SURFACE AS REQUIRED FOR NEW FINISH SORAYA@MATTERINTERIORS.COM EXISTING WOOD SIDING 1-1 L____, BE REMOVED D-42 EXISTING HORIZONTAL AND VERTICAL WOOD SIDING TO BE ENTIRELY NICOLE STEWART REMOVED,TYP.G.C.TO PREP WALL SURFACE AS REQUIRED FOR NEW FACADE NICOLE@MATTERINTERIORS.COM _, DEMO SKYLIGHT.NO FINISH. REPLACEMENT.INFILL ROOF D-43 EXISTING ROOF AND STRUCTURE TO REMAIN.G.C.TO VERIFY EXISTING CONDITIONS AND REPAIR AS REQUIRED. DEMOLITION-NORTH ELEVATION SCOPE/AREAS NOTES DRAWINGS AND SPECIFICATIONS DESCRIBES THE GENERAL SCOPE OF THE PROJECT AND DESIGN �l��LL++JJ CONCEPT IN TERMS OF THE INTERIOR DESIGN, C B Al CI _ - - ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND o-ae PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT UPPER LEVEL NECESSARILY INDICATE OR DESCRIBE ALL OF THE DEMO WINDOW/ WORK REQUIRED FOR THE FULL PERFORMANCE AND EXTERIOR WALL DW7 I 5 COMPLETION OF THE REQUIREMENTS OF THE 5 - - - - - - - - ROOF LEVEL TO BE INFILLED 18 SF CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, _��114.11F117"iy-_.- "- EL.+21'-51/4" L-----J DESCRIBED OR INFERRED,THE CONTRACTOR SHALL ��.. s:Z�ZiIi�� DWALL-• _ � - J ITEMSDETE NINE AND SSARY LUDE IN TO THE PROSALSPER ALL -�� - INFILL'I i"� - I I r - - 1 ITEMS NECESSARY TO PROVIDE THE PROPER - y a,^ r 7 r EXECUTION AND COMPLETION OF THE WORK. •�- i /���TI LOWER LEVEL I GENERAL NOTES: ® IIM3J.®So:41. ® iltre I�����/►��,�4lei"oo� a� eu�II: DEMO TYP ���,,��®� ®��- y��I4►��� "� p � WINDOWS FOR DW25 I DW26 I DW30 I 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO - Mtz=��.�y�r_ -A'969__ �;�II , ���A ,I�. �.as1T�AFii9HY>f_______ REPLACEMENT 17 SF 17 SFL 12 SF - CONSTRUCTION AND/OR FABRICATION. CM oug iM TYP - _ -_-- 1 -- ows - - - rr� PROJECT ® DWALL-7 NI HiNIIIIIMI 1 �ll Z12/1 729 W FRANCIS ST UPPER LEVEL I UPPER LEVEL �� ASPEN, CO, 81611 - UPPER LVL r 4 LL-' EL.+9'VI; iiil INFILL AREA AT I INFILL-1 DEMO WALL TO P DWALL-2 Yi REMOVED ACCOMODATE WINDOW 1IS I NEW WINDOW ��Z/12SFA 4 1' .i- 1i/i .I PROJECT TYPE LOWER LEVEL ifOCklmr1°1r' , {- � 9t 91 Al' mTMP OD SCREEN DEMO POR „sF INTERIOR ALTERATION ® 'p( �, �•��� , _ :- --. REPLACEMENT J r-z��#A ® ALTERATIONS AOW LOWER LVL 11 5 A NORTH BUILDING DEMO ELEVATION DEMOLITION-EAST ELEVATION SCOPE/AREAS ISSUE SCALE: 1/4I=1'-0" r -I 3 NO. I REVISION DESCRIPTION I DATE 3 I I 11 'ISSUE FOR PERMIT I05/24/2021 I UPPER LEVEL 1 DEMO WINDOW/ EXTERIOR WALL DW9 1 5 cm II I I 4 II 3.1 CM Ilrl I 1� GA 1 TO BE INFILLED 13 SF ��-- . r - _ ROOF LEVELEn r r- - - - UPPER LEVEL 1 I 1 I l' ' 1 , ,W4111 /. DEMO MI --- --- _ - ` I, �,��.�� .�;-®�L, „ ��1♦ WINDOWS FOR owe DW10 DW77 DW12 - ��` —- .1 A.1�� � , =1 Is♦♦I �i, (I, REPLACEMENT 13 SF 9 SF 13 SF 16 SF am -L- J_L- ----J- Wr in: m _„ I. Al,,, iW DWALL- ?� DWALL-6 4'� �0'�is I ®i�� ❑ 2 TYP. :=fr; �� .� JI ���E sl_! � ��yti� 10�r1� J ®� 1 n -I I 1 2 L�,1 ' sA`s i 1►4► sell=le ® �)�1 I . ._ *A -- - LOWER LEVEL 1 DYIMILL-3 DEMO LOWER LEVEL II 'F,.�,,8.�11'''I 0^ � WINDOWS FOR DW27 I I- DW28-1 DEMO DOOR FOR DD02 i ' • .... - III III LJ ,� II1lJ1811818 �� I""�TYP. REPLACEMENTli 19 SF 4 SF REPLACEMENT 20 SF PLANNING APPROVALS I'IIIIIIIIIIIIIIIIIIIIIIIIIIIIi1111111111 - - - III ' UEpE R LV9. I LL 2 �,� UPPER LEVEL INFILL AREA AT {10T I y l 1 REMOVED INFILL-2� LINFILL-34 11- LL-4�FI INFILL- LDJ. WINDOW v SHEET TITLE / j ZONING DEMOLITION j NORTH & EAST oae TYP UPPER LEVEL y / DEMO WALL TO % V 7/77/T FACADE ACCOMODATE 1 1 4 DD 0\J LOWER LVL NEW WINDOW ,�_ � _CLI�Ld _�![ULU [L I IIII EL.+a-0^ MODIFICATIONS DWALL-3 DWALL-4 DWALL-5 DWALL-6 DWALL-7 E m E m 6 SF 13 SF 4 SF 2 SF 24 SF SHEET NUMBER LOWER LEVEL EAST BUILDING DEMO ELEVATION SDEMO CR EN FOR / ,..,-7,, , RREPLACEMENT25 G 0 O SCALE: 1/4"=1'-0" S 45010E22° 1 A IB 1C ID IE 1F IG IH IJ 02020 MATTER PLANNINASEENN BUILDING DEPARTMENT A I B I C I D I E I F I G I H I J DEMOLITION ELEVATIONS LEGEND KEYNOTE LEGEND ' WINDOW SCHEDULE DEMOLITION SCOPE OF WORK SOUTH&WEST EXTERIOR DOOR SCHEDULE DEMOLITION SCOPE OF WORK SOUTH&WEST EXISTING D-31 l HATCH AREA INDICATES:EXISTING WINDOW AND/OR WALL AREA TO BE DEMOLISHED FOR NEW WIDNOW REPLACEMENT.REFER TO CONSTRUCTION PLANS AND ELEVATIONS ROUGH ROUGH DOOR SIZE SQ FT - - - TO BE DEMOLISHED FOR NEW SCOPE OF WORK,TYP. LEVEL ELEVATION SIDE MARK HEIGHT WIDTH SQ FT LEVEL ELEV SIDE MARK WIDTH HEIGHT DOOR MATTER KEYNOTE D-32 HATCH AREA INDICATES:EXISTING WINDOW TO BE DEMOLISHIED.NO WINDOW LOWER LVL SOUTH DW15 4'-4" 3'-10" 17 UPPER LVL SOUTH DD-05 3'-0" 6'-8" 20 TAG REPLACEMNET AT THIS LOCATION.INFILL EXTERIOR WALL TO MATCH EXISTING WALL PLANNING 7 LOWER LVL SOUTH DW16 4'-4" 3'-10" 17 LOWER LVL WEST DD-01 3'-0" 6'-8" 20 O DOOR TAG ASSEMBLY. 7 +I D E S I G N LOWER LVL SOUTH DW17 4'-4" 3'-10" 17 D-33 HATCH AREA INDICATES:EXTERIOR WALL TO BE DEMOLISHED AS REQUIRED FOR NEW LOWER LVL SOUTH DW18 4'-4" 3'-10" 17 WINDOW WINDOW LOCATION LOWER LVL SOUTH DW19 4'-4" 3'-10" 17 TAG D-34 EXISTING DOOR TO BE DEMOLISHED FOR REPLACEMENT AT SAME LOCATION. LOWER LVL SOUTH DW20 4'-4" 3'-10" 17 D-35 EXISTING DOOR TO REMAIN. LOWER LVL WEST DW21 4'-4" 3'-10" 17 �� NEW WINDOWROCFATION D-36 EXISTING LIGHT FIXTURE TO BE DEMOLISHED FOR REPLACEMENT. LOWER LVL WEST DW22 3'-4" 5'-0" 17 D-38 EXISTING SKYLIGHT TO BE DEMOLISHED.EXISTING OPENING TO BE INFILLED AND TO LOWER LVL WEST DW23 1'-3" 3'-0" 4 , DEMO WINDOW FOR MATCH EXISTING ROOF CONSTRUCTION. - MATTER PLANNINGSI DESiGN LLC DBC �O REPLACEMENT LOWER LVL WEST DW24 2'-10" 18 D-39 EXISTING EXTERIOR STUCCO TO BE ENTIRELY REMOVED,TYP.G.C.TO PREP WALL 299 MILWAUKEE ST STE 206 DENVER,CO 80206 6'-4' /2 DEMO WINDOW FOR SURFACE AS REQUIRED FOR NEW FACADE FINISH. 970-379-5401 E LCENSiE 12688 158 � REPLACEMENT AT SAME BUSINESS LICENSE 12685 UPPER LVL SOUTH DW1 5'-8" 8'-4" 48 LOCATION AT LOWER LEVEL D-40 HATCH AREA INDICATES:EXISTING WINDOWS AT LOWER LEVEL TO BE DEMOLISHED ' /�' DEMO WINDOW.NO FOR NEW WIDNOW REPLACEMENT AT SAME LOCATION AS EXISTING TO BE PROJECT TEAM UPPER LVL SOUTH DW2 5'-8" 8'-4" 48 DEMOLISHED,UNLESS OTHERWISE NOTED. v REPLACEMENT.INFILL UPPER LVL WEST DW3 4'-0" 4'-6" 18 EXTERIOR WALL D-41 EXISTING BALAUSTER TO BE REMOVED FOR REPLACEMENT.HANDRAIL STRUCTURE TO NOELLE HERNANDEZ UPPER LVL WEST DW4 4'-0" 4'-6" 18 EXISTING STUCCO TO REMAIN.G.C.TO VERIFY EXISTING CONDITIONS AND REPAIR AS REQUIRED.PREP NOELLE@MATTERINTERIORS.COM 6 UPPER LVL WEST DWS 4'-0" 4'-6" 18 L•_'::' BE REMOVED SURFACE AS REQUIRED FOR NEW FINISH 6 SORAYA GALLEGO UPPER LVL WEST DW6 4'-0" 4'-6" 18 EXISTING WOOD SIDING D-42 EXISTING HORIZONTAL AND VERTICAL WOOD SIDING TO BE ENTIRELY REMOVED,TYP. SORAYA@MATTERINTERIORS.COM 168 BE REMOVED G.C.TO PREP WALL SURFACE AS REQUIRED FOR NEW FACADE FINISH. NICOLE STEWART D-43 EXISTING ROOF AND STRUCTURE TO REMAIN.G.C.TO VERIFY EXISTING CONDITIONS NICOLE@MATTERINTERIORS.COM -_-_-_-3, DEMO SKYLIGHT.NO AND REPAIR AS REQUIRED. REPLACEMENT.INFILL ROOF D-44 HATCH AREA INDICATES:EXTERIOR WALL TO BE DEMOLISHED AS REQUIRED FOR NEW FIREPLACE VENTILATION PER MANUFACTURER'S SPECIFICATIONS. DEMOLITION-SOUTH ELEVATION SCOPE/AREAS NOTES r 1 DRAWINGS AND SPECIFICATIONS DESCRIBES THE r r r r GENERAL SCOPE OF THE PROJECT AND DESIGN I I CONCEPT IN TERMS OF THE INTERIOR DESIGN, ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND A D-sa ,.Ai) `B., ® C I I I PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL OF THE lig ElWORK REQUIRED FOR THE FULL PERFORMANCE AND 5 - - - - _ - - - - - ROOFLEVEL UPPER LEVEL UPPER LEVEL I I 5 COMPLETION OF THE REQUIREMENTS OF THE _1 EL.+2I'-5 1/4" DEMO DEMO DOOR CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, - -�-___ WINDOWS FOR DWI I I DW2 FOR DDOS DESCRIBED OR INFERRED,THE CONTRACTOR SHALL OM REPLACEMENT 48 SF 48 SF REPLACEMENT 20 SF DETERMINE AND INCLUDE IN THE PROPOSALS ALL - �� . .�- - ryP' i _i _ L-- J ITEMS NECESSARY TO PROVIDE THE PROPER - :,- EXECUTION AND COMPLETION OF THE WORK. �TYP. r - - - 1 r - - - 1 r 1 r 1 r - - - 1 ' 'r ,fl r - 1M- a �--_- i GENERAL NOTES: �_ ___v___� _ _ - y 1 ' n 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO LOWER cc LEVEL CONSTRUCTION AND/OR FABRICATION. �11M / / /dm I / DEMO� _ _ WINDOWS DW15 I I DW16 I I DW17 I I DW1s I DW19 I ® " = '®' I ,�I FOR REPLACEMENT NT _ PROJECT - 17 SFJ 17 SF J � 17 SF L 17 SF L 17 SF J a __I I. TYP.01 ill l Ed ' _ —I ® 1 ® lI/II/�Il/II/IIOII/IIO J��I�IIIIOII/II/JII/I1J wawa i'1 I • _ _ —III II II II II �%) ✓' 729 W FRANCIS ST V s e e DWALL-B I = DWALL-9 .� LJ��� II II II II II II II II II II II III UPPER LVL ✓f K ASPEN, CO, 81611 ail 1 - DWALL-10 I . � �,_ - DWAL ��7 IV// (� UPPER LEVEL DWALL-8 f� DWALL-9 di • /' IriL II / 11-_ % ' I DEMO WALL TO 110 SF V//1 110 SF . , li� I // _, IAo• I III r: TYP NEW WINDOW ACCOMODATE r � _V"_Z,ZZ'�=I PROJECT TYPE MI , 'IP 1' 0� + �+� II j��1�7����j� INTERIOR ALTERATION �_ '�! r �d _ PAI j'-. IB 0 . 1 ONLY+ WINDOW % 'fp ownLL-1i� ALTERATIONS I %%%% ;;%i •,' ' %,i %DWALL 12. .�_- ��� I , �'� /, I '-%�i!;, Z%G%%/L -�.1 EX LOWER LVL �����������G110 SF'/ 7. CM OM LOWER LEVEL �/7 DEMO WALL LTEO a "/�j//jJJ��pWALL,? V �,j�lr� ISSUE 5ASOUTH BUILDING DEMO ELEVATION NEW WINDOW ��«l 'L 144 SF%A_ ! ��<i�t�«__�G76LSF/V NO. I REVISION DESCRIPTION I DATE 3 SCALE: 1/4"=1'-0" 1/ ul 3 DEMOLITION-WEST ELEVATION SCOPE/AREAS 0 UPPER LEVEL r - - - -1r - - - -1r - - - -1r - - - -11 CO ®LI 0 LI LI 0 0 oaa DEMO EXTERIOR WALL • • • TO BE INFILLED 0--- _ Nma R.C2 -L EL WHERE WINDOW I _ a•_s_a_ oe, E E E -_--- ---- �i�_-----_-- - - - - - HAS BEEN DW3 DW4 DW5 DWB OOF INFILL m REMOVED 18 SF 18 SF 18 SF 18 SF TYP. d V zria gr- -•e-DWALL-17 - DWALL-1• ,DWALL-7 -� ' I r j it r ® 9.>D.e Trerff®!y.>�'� I,_ � I ,,, * orAar.� El LOWER LEVEL I I I e DEMO / I /I 4. II II WINDOWS FOR DW20 I I DW22 r DW23 1 1 DW24 1 I I 2 \ I I p• 'I /I,III �- I► I I r I I REPLACEMENT L 17 SF J_ 17 SF 1_L 4 SF 1 _-_-_-_18 SF J 2 U iL_ 1 I,I__ Is r — — 1 II 411414 I PLANNING APPROVALS • DW6== _... DW4 DW3 1II II II0II Il IIlUIlUXIlllll\T r 1 I I, -u u u u u u u — — — _ UPPE R+9 LV9 L EL. „ 1,,,,,,. ,-„,,,,,,,---,,,,,,,,,,, LOWER LEVEL I LOWER LEVEL I I _ _ . _ DEMOTEWINDOW/ORWALL DEMO DOOR I we INFILL 6: I °❑� EXTERIOR DW21 FOR DD01 1• �� I C j. 1liiiii* TYP. \ TO BE INFILLED L 17 SF J REPLACEMENT L20 SF D W2 / �� I �W2 II.{ N D I'� 40 1 .I \ UPPER LEVEL SHEET TITLE / 1 •11��• DEMO WALL TO eriz'r�zr�vrr� rszrzrizr�a W2 �.• C�I,y �II 1 \ ACCOMODATE C FIZZ/GI ZONING DEMOLITION K 11 � /�I NEW WINDOW errvrnJrv�_ SOUTH &WEST o 1. I�eciy_AJ 9P' Intel I' DWALL-13 DWALL-14 DWALL-15 DWALL-16 DWALL-17.:I II,L�I L�J�I 17 SF 17 SF 17 SF 17 SF 17 SF FACADE 1 If - .II LOWER LVL 1 MODIFICATIONS ❑ II El D-01 ❑ ® ® ��♦�♦�♦�♦�• SHEET NUMBER WEST BUILDING DEMO ELEVATION LOWER LEVEL :..... UPPERNFILL- 1 A INFILL AREA AT �; ROOF:INFILL AREA GcO4Er02. ED REMOVED AT REMOVED ROOF INFILL SCALE: 1/4°=1'-D" WINDOW -��� ,�y SKLYLIGHT L-_1 15 SF A I B C I D I E I F I G I H I J ®2020 MATTER PLANNIN4f1SM1114 BUILDING DEPARTMENT A I B I C I D I E I F I G I H I 3 WALL DEMOLITION CALCS CITY OF ASPEN ZONING SUBMISSIONill EXTERIOR WINDOW SCHEDULE NEW SCOPE OF WORK NORTH&EAST All KEYNOTE LEGEND LOWER LEVEL ROUGH ROUGH EL-1 NEW STANDING SEAM METAL WALL ATTACHED TO FIXED BRACKETS AND LEVEL ELEV SIDE MARK TYPE ROOM NAME HGTH. WIDTH SQ FT U-VALUE MANUF. NOTES HORIZONTAL CARRIER RAILS TO EXISTING BUILDING AND TO BE SECURELY SO.FT. SQ.FT. ATTACHED TO BUILDING. MATT E R ELEVATION SQ.FT. SQ.FT. SQ.FT. SQ.FT. EXISTING TO REMAIN+ EXT WALL MINUS EXIST SQ.FT.INFILL LOWER LVL EAST LLW-07 SLIDING LL-BEDRM 1 3'-6 1/4" 6'-0 1/4" 21 0.25 KOLBE EGRESS SIDE/WALL EXISTING EXISTING DEMO EXT. DEMO NEW FENESTRATION TO REMAIN&NEW EXT.WALL EL-2 NEW WINDOW AND/OR DOOR. EXT.WALL FENESTRATION WALL FENESTRATION FENESTRATION LOWER LVL EAST LLW-08 AWNING LL-BATH 1 2'-0 1/4" 3'-6 1/4" 7 0.25 KOLBE PLANNING 7 NORTH 334 51 N/A N/A 51 �"°°'"'°E'� 334 N/A LOWER LVL NORTH LLW-OS SLIDING LL-BEDRM 2 3'-6 1/4" 5'-0 1/4" 18 0.26 KOLBE EGRESS EL-3 NEW WOOD SIDING AND WD BATTENS.FINISH TO BE PAINTED 7 EL-4 NEW EXTERIOR WOOD SIDING.FINISH TO BE PAINTED. +I D E S I G N EAST 430 46 N/A N/A 46 ,"" '• 430 N/A LOWER LVL NORTH LLW-06 SLIDING LL-BEDRM 1 3'-6 1/4" 5'-0 1/4" 18 0.26 KOLBE EGRESS EL-6 NEW PERFORATED METAL SCREEN. SOUTH 384 122 96 101 148 TZ—Za,a."," 358 -26 LOWER LVL NORTH LLW-09 AWNING LL-LAUNDRY 4'-0 1/4" 3'-0 1/4" 12 0.25 KOLBE EL-7 NEW GUTTER,TYP.THROUGHOUT AT EXISTING ROOF.FINISH TO BE PAINTED WEST 375 102 o 40 85 ;.,"q.=,".,.,. 392 +17 76 EL-8 NEW BLACKENED METAL FRAME AROUND WINDOWS AND/OR DOOR,TYP. TOTAL 1,523 321 141 303 -9 UPPER LVL EAST UPW-10 SLIDING MASTER 4'-0 1/4" 6'-0 1/4" 24 0.26 KOLBE EGRESS EL-9 NEW CANOPY MADE OF BLACKENED METAL PLATE. BEDROOM UPPER LEVEL EL-10 NEW EXTERIOR LIGHT FIXTURE TO BE INSTALLED WHERE EXTERIOR LIGHT UPPER LVL EAST UPW-11 FIXED BATHRM 1 1'-0 1/4" 5'-6 1/4" 5.5 0.25 KOLBE SQ.FT. SQ.FT. WAS DEMOLISHED. HERE _ NCH DESIGN,LLC DBA ELEVATION SQ.FT. SQ.FT. SQ.FT. SQ.FT. EXISTING TO REMAIN+ EXT WALL MINUS EXIST SQ.FT.INFILL UPPER LVL EAST UPW-12 CASEMENT TOILET RM1 6'-0 1/4" 2'-0 1/4" 12 0.24 KOLBE MATTER PLANNING+DESIGN LLC SIDE/WALL EXISTING EXISTING DEMO EXT. DEMO NEW FENESTRATION TO REMAIN&NEW EXT.WALL EL-12 FIREPLACE VENT 299 MILWAUKEE ST STE 206 DENVER,C080206 EXT.WALL FENESTRATION WALL FENESTRATION FENESTRATION UPPER LVL EAST UPW-13 CASEMENT VESTIBULE 6'-0 1/4" 2'-0 1/4" 12 0.24 KOLBE EL-14 EXISTING EXPOSED STRUCTURE.REPAIR AND REFINISED AS REQUIRED. 970MATT401 I www.matterinterIGN m NORTH 290 22 32 22 24 UPPER LVL NORTH UPW-08A AWNING BEDROOM 1 1'-6 1/4" 4'-0" 6 0.25 KOLBE BUSINESS LICENSE 12685 (NEW) 288 -2 UPPER LVL NORTH UPW-08B AWNING BEDROOM 1 1'-6 1/4" 4'-0" 6 0.25 KOLBE EL-15 EXISTING EDGE OF ROOF.REPAIR AND REFINISHED AS REQUIRED. EAST 339 79 60 79 52 (NEW) 366 +27 EL-16 NEW FLASHINGAT4"A.F.F. PROJECT TEAM SOUTH 312 127 51 127 149 (NEW) egg -2z UPPER LVL NORTH UPW-09A AWNING MASTER 1'-6 1/4" 4'-0" 6 0.25 KOLBE BEDROOM EL-17 NEW GLASS BALAUSTER. WEST 344 81 208 81 51 (NEW) 374 +ao UPPER LVL NORTH UPW-09B AWNING MASTER 1'-6 1/4" 4'-0" 6 0.25 KOLBE EL-18 EXTSNG HANDRAIL STRUCTURE TO REMAIN AND TO BE PAINTED NOELLE H NOELLE@MATTERINTERIORS.COM 6 TOTAL 1,285 309 309 276 +33 BEDROOM EL-19 NEW METAL PLATE TO WRAP STANDING SEAM MEATL WALL AND WOOD SIDING 6 EL-20 NEW BLACKENED METAL FRAME TO TERMINATE EDGE OF STANDING SEAM SORAYAGALLEGO ROOF EXISTING TO REMAIN. METAL SORAYA@MATTERINTERIORS.COM DEMO(1)EXISTING L , ERIOR DOOR SCH - E-NEW SCOPE OF WORK NORTH&- EL-21 FAUX WOOD BOARD.PAINTED FISNIH NICOLE STEWART INFILL 15 SF.THERMAA BARRIER L BARRIER WITH NOMINAL 2X4 TIMBER AND INSULATION.MATCH CONSTRUCTION NICOLE@MATTERINTERIORS.COM ASSEMBLY MATERIALS AND FINIHSES. DOOR SIZE SQ FT LEVEL ELEV SIDE MARK DOOR TYPE ROOM NAME R.O.WIDTH R.O.HEIGHT DOOR U-VALUE MANUF LOWER LVL EAST LLDR-04 SINGLE SWING LL-MUD RM 3'-0 3/8" 6'-11 1/4" 21 0.29 KOLBE ELEVATIONS LEGEND NOTES KEYNOTE TAG NEW STANDING SEAM NEW WOOD SIDING DRAWINGS AND SPECIFICATIONS DESCRIBES THE METAL WALL GENERAL SCOPE OF THE PROJECT AND DESIGN t CONCEPT IN TERMS OF THE INTERIOR DESIGN, ES/ OAl ® O ® DOOR TAGNEW METAL FRAME ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND NEW WOOD SIDING AND 0AROUND WINDOWS PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT WOOD BATTENS OR DOORS NECESSARILY INDICATE OR DESCRIBE ALL OF THE WINDOW TAG WORK REQUIRED FOR THE FULL PERFORMANCE AND E5 COMPLETION OF THE REQUIREMENTS OF THE 5 ROOF LE VEL CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, �� ® DESCRIBED OR INFERRED,THE CONTRACTOR SHALL — �"" _ GENERAL NOTES DETERMINE AND INCLUDE IN THE PROPOSALS ALL --• - !PA ITEMS NECESSARY TO PROVIDE THE PROPER � ••• '4 1 I 1 -� -CONTRACTOR TO CONFIRM ALL NEW EXTERIOR DOORS AND WINDOW SIZES WITH EXECUTION AND COMPLETION OF THE WORK. Oil • �L MANUFACTURER AND SPECIFICATIONS. T/WINDOW 0 GENERAL NOTES: / // N. // N /// N %/ 1■ ^ EL=T-3" -BEAR RESISTANT DOOR HARDWARE FOR EXTERIOR DOORS. 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO JBI.1 N. TYP. CONSTRUCTION AND/OR FABRICATION. 1 U W-0 U W-0 W-0 U W-0 PROPOSED-NORTH ELEVATION SCOPE/AREAS PROJECT /// // //. . 4 ST NEW WINDOW r - - - 7 r - - - 1 r - - - 1 r - - - 1 ASPEN, CO 81611 �B�I i i UPPER+ LVL LOCATION , : , 1 UPW-08A UPW-08B UPW-09A UPW-0 9B 1 'LL-1/NEWi i i,ii ,i,�,�,', 1 6SF 6SF 6SF 6SF 1 f - �� PROJECT TYPE n ® TYP. Z -/l � 111- l/i l/i- l/i-' F — - -I MO .../ /// rvP LOWER LEVEL I I I I I INTERIOR ALTERATION 1 II : PLACE AT SAME I LLWOS LLWO6 LLWO9 ONLY+ WINDOW �. \LW-0 TYP• LOCATION 18 SF 18 SF 12 SF ® �° ® ----JL �_� � ALTERATIONS 1 I . . .t u _ LOWERLVL SE TYP III: TYP. LOWER LEVEL ID-03.1 DEMO WOOD R�?.T-1.1'i'1.1.1'i'1.1-i-r'1.1-i'i-1.1-i� ISSUE 1 ANORTH BUILDING ELEVATION SCREEN FOR 1'1'1'1'1'1'1'1'1'1'1'1',',':i LL-1INEW REPLACEMENT yiili:il�ilili:il�ilili:il�ili:ilil�ili:i:il�il�1 1. 17 SF NO. REVISION DESCRIPTION DATE 3 SCALE: 1/4"=1'-0" 5 3 11 'ISSUE FOR PERMIT I05/24/2021 I 5 T .1 .1 1 T OM ® ® 3 ® � T 2 _ — T ROOF LEVEL PROPOSED-EAST ELEVATION SCOPE/AREAS EL.+21'-5 1/4" T/WINDOW I ---------- ��_ EL=7-3"0 Ir l I I 0I ' /// /// ® UPPER LEVEL 2 NEW WINDOW - 2 7 LOCATION I UPW-10 UPW-11 UPW-12 UPW-13 /// I// //` 0F‘' 24 SF 5.5 SF 12 SF 12 SF PLANNING APPROVALS i / U r ry 1 UPPER LVL r 1 // : �ii LL-2/NEWI�I�IIi I�I�I�I,I�I�I�I,I�I�I�I,I�I III III s` I I / I;lililili l�I�lil;l il ililili l�I;lilil / _ LOW R WINDO LI _ LOW WINDOR LI I // NEW WINDOW-PLACE AT I —INEW WINDOW- I LLDR-04 ISHEET TITLE / 11 1 ., 1 /// _. /// ` .. ® LOCATIONSAME J L —JLOCATIONPLACE AT SAME L20SF ZONING PROPOSED ( ® I LLW-07 LLW-08NORTH & EAST ® FACADE 1 24 SF 5.5 SF 1.. I li LOWERLVL� MODIFICATIONS II��BB��: EL-9 / : : : 5H 1 EL.+O'-0" LOWER LEVEL Yi7Y -0 I ® ® ID-03.1 P DEMO WOOD nn7-17n7-17nl-17nl-177-1-1-17-17LL NEW SHEET NUMBER SCREEN FOR r�,', IDA3.1 REPLACEMENT r�,l i l l'I l l Y�11 111111'1 111111111 l�i i i 111 1 E EAST BUILDING ELEVATION i .,., l , ' I ' I '.I.' ' I.'.I ' I.'.'.I�I�'.I LL_.F, I , C J J G 0_0 4(!$VED A I B I C I D I E I F I G I H I J ®2020 MATTER PLANNINONSEE f N BUILDING DEPARTMENT A 1 B 1 C 1 D 1 E 1 F 1 G 1 H 1 J WALL DEMOLITION CALCS CITY OF ASPEN ZONING SUBMISSION EXTERIOR WINDOW SCHEDULE NEW SCOPE OF WORK SOUTH&WEST KEYNOTE LEGEND LOWER LEVEL ROUGH ROUGH EL-1 NEW STANDING SEAM METAL WALL ATTACHED TO FIXED BRACKETS AND SQ.FT. SQ.FT. LEVEL ELEV SIDE MARK TYPE ROOM NAME HGTH. WIDTH SQ FT U-VALUE MANUF. NOTES HORIZONTAL CARRIER RAILS TO EXISTING BUILDING AND TO BE SECURELY MATTER ELEVATION SQ.FT. SQ.FT. SQ.FT. SQ.FT. EXISTING TO REMAIN+ EXT WALL MINUS EXIST SQ.FT.INFILL ATTACHED TO BUILDING. SIDE/WALL EXISTING EXISTING DEMO EXT. DEMO NEW FENESTRATION TO REMAIN&NEW EXT.WALL LOWER LVL WEST LLW-01 CASEMENT LL-LIVING RM 4'-0 1/4" 4'-6 1/4" 18 0.26 KOLBE EXT.WALL FENESTRATION WALL FENESTRATION FENESTRATION LOWER LVL WEST LLW-02 SLIDING LL-BEDRM 3 4'-0 1/4" 4'-0 1/4" 16 0.26 KOLBE EGRESS EL-2 NEW WINDOW AND/OR DOOR. PLANNING 7 NORTH 334 Si N/A N/A 51 ^'"°"°"'"" 334 N/A LOWER LVL WEST LLW-03 AWNING LL-BATH 2 2'-0 1/4" 3'-6 1/4" 7 0.25 KOLBE EL-3 NEW WOOD SIDING AND WD BATTENS.FINISH TO BE PAINTED 7 +I D E S I G N EAST 430 46 N/A N/A 46 '"°°"'''.., 430 N/A LOWER LVL WEST LLW-04 SLIDING LL-BEDRM 2 3'-6 1/4" 6'-0 1/4" 21 0.25 KOLBE EGRESS EL-4 NEW EXTERIOR WOOD SIDING.FINISH TO BE PAINTED. SOUTH 384 122 96 101 148 1,7=ro .,„ 358 -26 62 EL-7 NEW GUTTER,TYP.THROUGHOUT AT EXISTING ROOF.FINISH TO BE PAINTED WEST 375 102 0 40 85 a,"....T),.ro " 392 +17 UPPER LVL WEST LLW-03 AWNING LIVING RM 2'-0 1/4" 3'-6 1/4" 6 0.26 KOLBE EL-8 NEW BLACKENED METAL FRAME AROUND WINDOWS AND/OR DOOR,TYP. TOTAL 1,523 321 141 303 -9 UPPER LVL WEST UPW-03 AWNING LIVING RM 2'-0 1/4" 3'-0 1/4" 6 0.26 KOLBE EL-9 NEW CANOPY MADE OF BLACKENED METAL PLATE. UPPER LEVEL UPPER LVL WEST UPW-05 SLIDING BEDROOM 2 4'-6" 4'-6" 20.25 0.31 KOLBE EGRESS EL-10 NEW EXTERIOR LIGHT FIXTURE TO BE INSTALLED WHERE EXTERIOR LIGHT WAS - SQ.FT. sQ.FT. UPPER LVL WEST UPW-06 FIXED BATHRM 2 1'-0 1/4" 4'-0 1/4" 4 0.25 KOLBE DEMOLISHED. HERE - NCH DESIGN,LLC DBA ELEVATION SQ.FT. SQ.FT. SQ.FT. SQ.FT. EXISTING TO REMAIN+ EXT WALL MINUS EXIST SQ.FT.INFILL EL-11 NEW EXTERIOR LIGHT FIXTURE LOCATION. MATTER PLANNING+DESIGN LLC SIDE/WALL EXISTING EXISTING DEMO EXT. DEMO NEW FENESTRATION TO REMAIN&NEW EXT.WALL UPPER LVL WEST UPW-07 SLIDING BEDROOM 1 4'-6" 4'-6" 20.25 0.31 KOLBE EGRESS - 299 MILWAUKEE ST STE 206 DENVER,CO 80206 EXT.WALL FENESTRATION WALL FENESTRATION FENESTRATION 56.5 EL-12 FIREPLACE VENT 970-379-5401 I www.matterinteriors.com NORTH 290 22 32 22 24 (NEW) 288 -2 IIMIIEWEL-13 EXISTING WOOD COLUMNS IN THE FOREGROUND BUSINESS LICENSE 12685 EXTERIOR DOOR SCHEDULE-NEW SCOPE OF WORK SOUTH&WEST EL-14 EXISTING EXPOSED STRUCTURE.REPAIR AND REFINISED AS REQUIRED. EAST 339 79 60 79 52 (NEW) 366 +27 PROJECT TEAM SOUTH 312 127 51 127 149 (NEW) 290 -22 DOOR SIZE SQ FT EL-15 EXISTING EDGE OF ROOF.REPAIR AND REFINISHED AS REQUIRED. WEST 344 81 208 81 51LEVEL ELEV SIDE MARK DOOR TYPE ROOM NAME R.O.WIDTH R.O.HEIGHT DOOR U-VALUE MANUF EL-16 NEW FLASHING AT 4"A.F.F. NOELLE HERNANDEZ 6 (NEW) 374 +3o LOWER LVL SOUTH LLDR-02 SINGLE SWING LL-LIVING RM 8'-0 1/4" 7'-11 3/4" 60 0.26 KOLBE EL-17 NEW GLASS BALAUSTER. 6 NOELLE@MATTERINTERIORS.COM TOTAL 1,285 309 309 276 +33 LOWER LVL SOUTH LLDR-01 SLIDING LL-DINING 8'-0 1/4" 7'-11 3/4" 60 0.26 KOLBE EL-18 EXTSING HANDRAIL STRUCTURE TO REMAIN AND TO BE PAINTED SORAYAGALLEGO ROOF EXISTING TO REMAIN. LOWER LVL WEST LLDR-03 SLIDING LL-LIVING RM 3'-0 3/8" 6'-11 1/4" 21 0.29 KOLBE EL-19 NEW METAL PLATE TO WRAP STANDING SEAM MEATL WALL AND WOOD SIDING SORAYA@MATTERINTERIORS.COM DEMO(1)EXISTING SKLYLIGHT, UPPER LVL SOUTH UPDR-03 SINGLE SWING VESTIBULE 3'-0 3/8" 6'-11 1/4" 21 0.29 KOLBE EL-20 NEW BLACKENED METAL FRAME TO TERMINATE EDGE OF STANDING SEAM NICOLE STEWART BARRIERINFILL 15 SF.THERMAL NOMINAL 2X4 TIMBER AND INSULATION.MATCH CONSTRUCTION UPPER LVL SOUTH UPDR-02 SLIDING EXISTING DECK 8'-0 1/4" 7'-6" 60 0.26 KOLBE METAL NICOLE@MATTERINTERIORS.COM ASSEMBLY MATERIALS AND FINIHSES. UPPER LVL SOUTH UPDR-01 SLIDING EXISTING DECK 8'-0 1/4" 7'-6" 60 0.26 KOLBE EL-22 INFILL ROOF OPENING WHERE SKYLIGHT HAS BEEN REMOVED.INFILL TO MATCH EXISING ROOF CONSTRUCTION. ELEVATIONS LEGEND NOTES KEYNOTE TAG NEW STANDING SEAM NEW WOOD SIDING DRAWINGS AND SPECIFICATIONS DESCRIBES THE T METAL WALLGENERAL SCOPE OF THE PROJECT AND DESIGN 0 ® � • ® OF THE INTERIOR DESIGN, ARCHRECTUCONCEPT IN TRAL MERMS ECHANICAL,CAL ELECTRICAL,AND XXX DOOR TAG NEW FRAME NEW WOOD BATTENS SIDING AND /// NEW METALS FRAME PLUMBING SYSTEMS.THERE DOCUMENTS DO NOT WOOD BATTENS OR DOORS NECESSARILY INDICATE OR DESCRIBE ALL OF THE WINDOW TAG WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 ROOF LEVEL S COMPLETION OF THE REQUIREMENTS OF THE _�-�..••• iy ���_ EL.+21'-51/4" CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, 31 .4-,"-WO '-'- DESCRIBED OR INFERRED,THE CONTRACTOR SHALL Yiiil —� ��i /jy---���_ GENERAL NOTES DETERMINE AND INCLUDE IN THE PROPOSALS ALL —� 0. l $1101 �" ITEMS NECESSARY TO PROVIDE THE PROPER G� -61i -• ! �_ -CONTRACTOR TO CONFIRM ALL NEW EXTERIOR DOORS AND WINDOW SIZES WITH EXECUTION AND COMPLETION OF THE WORK. — a '� MANUFACTURER AND SPECIFICATIONS. f Il11.1 GENERAL NOTES: - Yi®-r0 -BEAR RESISTANT DOOR HARDWARE FOR EXTERIOR DOORS. ® ► , 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO P6R-0 Y(PDR-03 - ® CONSTRUCTION AND/OR FABRICATION. �/ �/ I" A� ® PROPOSED-SOUTH ELEVATION SCOPE/AREAS PROJECT 00 / I729 W FRANCIS ST �/ I// 11 I �/ �/ �/ �/ ' ASPEN, CO, 81611 �i id I H1 aPDR 3 - UPPER LVL 4 EL.+9,-9„ r �� II 1111II IIII11 11 11 11 1 0 I II u uIIII1( IIIII I t YYY I 4 1I2'-0" ''2'-0"I (� - ��1I I - ►1 , O. - - • 8711 UPPER LEVEL I PROJECT TYPE I NEW DOOR- UPDR-01 UPDR-02 1 PLACE AT SAME UPDR-03 ® - I a a T LOCATION L 605L_L 60SFlii L20SF J INTERIOR ALTERATION 01: - . 1 i ONLY+ WINDOW ALTERATIONS .Y �. —���, ,1� 1.". .��.�_ .n .. .� LOWER LVL LDR-0 �. EL.+0'-0"� ® ® TYP ISSUE 5ASOUTH BUILDING ELEVATION NO. 1 REVISION DESCRIPTION I DATE 3 SCALE: 1/4"=1'-0" LOWER LEVEL 3 NEW DOOR- 1 ISSUE FOR PERMIT 05 2 1 1 PLACE AT SAME LLDR-01 LLDR-02 I /4/2021 O LOCATION - 60 SFJ 60 SF� 3 3.1 4 CEILING 5 i I ,7-, JOIST L�J I ROOF LEVEL PROPOSED-WEST ELEVATION SCOPE/AREAS I EL.+21'-5114' UPW-08 UPPER LEVEL 4 SF NEW WINDOW ` d T1 �k �T1 �1 d d d �, ,, r _ -_-_-_-_ J IT -—f—-— - - ----------------- TEL/WINDOW LOCATION L _� I 2 0 0 r,..,„,.: I�1 II II 1 I I 1 2 ® • Yitifi UPPER LEVEL PW-0 PW-0 i I!— NEW WINDOW- PLACE AT SAME UPW-0 PUPW-04 UPW-05 UPW-07 021 LOCATION L6 SF L6 SF_1 L 20.25 SF L 20.25 SF _1 PLANNING APPROVALS . J �s UPPER LVL 1 m\ o I I r LOWER LEVEL r - 71 I I �1,1 NEW WINDOW- i1Y - /I / LLW-01 LLW-02I�// MC // PLACE AT SAME 18SF I18 SF L78PS L2W SF 4 SHEET TITLE ® /// /// /// / /// ///- ® LOCATION 1_ —_—_—_L_L_—_J_L— J_L_—_—_—_ 121 . LW-0 / /// - Z \\ ZONING PROPOSED LW • LW-0 � ' \ o Iwo r SOUTH &WEST \ - ® \ FACADE 1 �� LOWERLVL 1 MODIFICATIONS 1 El ma 5H i7rY ()__DR-03 5E • EL.+0'-0 ID-03.1 !Eu.,l ® ID-031 LOWER LEVEL 1 SHEET NUMBER 1 AWEST BUILDING ELEVATION NEW DOOR- LLDR-03 PLACE AT SAME G 0-022 LOCATION L2LSF i ED 1 A 1 B I C 1 D 1 E I F 1 G 1 H 1 J ®2020 MATTER PLANNINASEENN BUILDING DEPARTMENT A 1 B 1 C D 1 E 1 F G H 3 MATT E R .,:::;-.. 7 AV °ay.}��, ttl 2tta: ., „k��ti d'i:i� °* -'7-C �y � +,. ,\i. ,y�V� .,, � .t ~� PLANNING m tT os: ' 'fi r �-,A '` - - - r t` (DESIGN 4 iv- • oviiii h�'i.�' n , o '+INf" .-,f r tea: /sAxr- i ° a• _. ��R F` �f. / 2 gat !ll.. • ,h _ NCH DESIGN,LLC DBA "-- 299 MILWAUKEE ST STE 206 DENVER,CO 80206 0 "FIT' + '� � ,.-y �` ''� .� 4 F _ ',� ~ MATTER PLANNING+DESIGN LLC A ` - /n7- ,�;rfi`, - i .t _ Al p r Al:• T •` �y 'W. '^ - ,,, - ��,rir, 1IPI y. r ! r \all— J _ . :::::D79t5 .0„._ `. .., ` � RIN6 �. } v ": 4 ;.. ; t 44t 6NOELLE@MATTERINTERIORS.COM ( {ti � �t ti� -.1 ,- pLai ° .1 ......-jr - c�4.I I_! 4� SORAYA GALLEGO - Le !!, 1 !„.• SORAYA@MATTERINTERIORS.COM .'`.• - 111 I I ,�•' _ NIC TTERINTERIORS COM [ \ NICOLE STEWART OLE MA 1 )11L1 ...• . . ;',.:. ;'" :AO . Of '..--- '1...im_FR r I ' ., I .' 100' sesAtIrki 29"4111L“Nillill _ .�� �. - ( ,-.• - NOTES n ' - _ ` I .I DRAWINGS AND SPECIFICATIONS DESCRIBES THE iF _ ,y� GENERAL SCOPE OF THE PROJECT AND DESIGN -- �qN„'�l _ 11'I_ - - - " CONCEPT IN TERMS OF THE INTERIOR DESIGN .' Y _ � r- r ♦ - - y`. C _ - ARCHRECTURAL,MECHANICAL,ELECTRICAL,AND - PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT _ - aw„ a y�`y�l� NECESSARILY INDICATE OR DESCRIBE ALL OF THE _ • - - -- 3'` _ ,_ _ alk - _ WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 • -.p' 'r�i T -*i - _ - ^a._�:.- - 5 COMPLETION OF THE REQUIREMENTS OF THE 11106 CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, DESCRIBED OR INFERRED,THE CONTRACTOR SHALL EXISTING NORTH/ WEST FACADE EXISTING NORTH/ EAST FACADE EXISTING SOUTH FACADE ITEMS NINE AND SSARY TLUDEINTHEPROPOSALS ALL ITEMS NECESSARY TO PROVIDE THE PROPER EXECUTION AND COMPLETION OF THE WORK. SCALI3/32"=1'-0" SCAU3/32"=1'-0" SCALI3/32"=1'-0" GENERAL NOTES: 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION AND/OR FABRICATION. -Mil PROJECT • ik 729 W FRANCIS ST - , IIMMIP i ASPEN, CO, 81611 ���� / 011 ,.iN y PROJECT TYPE 0 .11..- ii I ' 4 INTERIOR ALTERATION "1",-.01 .L'4,5tri', v- ri,i.:4,1.4tir.kltli, voi I`IIli 1 II" ..Ion ONLY+ WINDOW b , . , , ,3 -.._._ _1! i I I _,-0 0 ALTERATIONS III ild: i Illi_411 ___ I II I , •,... . _ _ _...t... 1 ' 1 ' I ISSUE _ owl IN 3 :lit __ E' 1Tl , . IIPPI on. 0:11 +I I41 �\�R 3 NO. REVISION DESCRIPTION DATE _ . k I. _._ ,_ .,. • C:1 . [I f"lk ., . L. ^t" �tV 0 2 PROPOSED NORTH/ WEST VIEW PROPOSED NORTH/ EAST VIEW PROPOSED SOUTH/ WESTVIEW 2 SCALE:1/8"=1'-0" SCALE:1/8"=1'-0" SCALE:1/$"=1'-D" PLANNING APPROVALS SHEET TITLE EXISTING PHOTOS AND PROPOSED FACADE ' 1 MODIFICATIONS SHEET NUMBER GO-O4E 2 A 1 B I C 1 D 1 E I F 1 G I H I J ®2020 MATTER PLANNINCASELEMN BUILDING DEPARTMENT A I B 1 C D I E 1 F I G 1 H I J 01. GENERAL 03. DEMOLITION 05. CEILINGS 07. MILLWORK MATTER 1 1 PLANNING 1.SUSPENTION:WHERE APPLICABLE DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A 1.STANDARDS:MILLWORK AND CABINETS TO COMPLY WITH THE"ARCHITECTURAL WOODWORK 7 1.RULES:ALL WORK SHALL CONFORM TO APPLICABLE CODES AND COMPLY WITH ALL LAWS, 1.VERIFY FIRST:CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING 'LATERAL FORCE OF 20%OF THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUATARY TO STANDARDS".WOOD MILLWORK TO BE PREMIUM GRADE AND LAMINATE MILLWORK TO BE CUSTOM 7 ORDINANCES,RULES,REGULATIONS,AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING ON DEMOLITION OF EACH AREA AND PROMPTLY REPORT ANY DISCREPANCIES TO THE ARCHITECT. 1 THE SYSTEM.USE A MINIMUM CEILING WEIGHT OF 5 POUNDS PER SQUARE FOOT TO DETERMINE THE GRADE TYP.CABINET,DOOR,AND DRAWER FRONT INTERFACE STYLE TO BE FLUSH OVERLAY UNLESS +I D E S I G N THE PERFORMANCE OF THE WORK.ALL COVID SAFETY GUIDELINES AND RULES APPLY. 1 LATERAL FORCE. NOTED OTHERWISE. 2.REMOVALS:WHERE DEMOLITION AND/OR REMOVAL IS INDICATED,IT IS INTENDED TO SHOW THE 2.FEES:THE CONTRACTOR SHALL SECURE AND PAY FOR THE DEMOLITION AND ALL OTHER REQUIRED GENERAL NATURE OF EXISTING CONDITIONS AND EXTENT OF WORK.IT IS NOT TO BE CONSIDERED A '2.LOADS:WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE 2.SHOP DWGS:MILLWORK SHOP DRAWINGS SHALL INDICATE ALL JOINTS AND SEAMS/EDGES.PRECISE PERMITS,FEES,LICENSES,AND INSPECTIONS NECESSARY FOR THE PROPER EXECUTION AND RECORD DRAWING OF EXISTING CONDITIONS. 'PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM,THE FOLLOWING BRACING METHODS MAY DIMENSIONS AT MILLWORK TO BE FIELD VERIFIED TYPICAL. COMPLETION OF THE WORK. i BE EMPLOYED: 3.METHODS:CONTRACTOR SHALL SUBMIT A SCHEDULE OF METHODS AND OPERATIONS FOR ALL 3.INTERIOR:INTERIOR OF WOOD VENEER CABINETS TO BE WOOD VENEER TO MATCH EXTERIOR FINISH. 3.INSURANCE:CONTRACTOR SHALL PROVIDE PROOF OF INSURANCE PRIOR TO THE START OF THE DEMOLITION AND REMOVAL WORK FOR THE OWNERS INFORMATION.THE SCHEDULE SHALL INDICATE : 2.1:PROVIDE A LATERAL SUPPORT BY FOUR WIRES OF MINUMUM NO.12 GUAGE SPLAYED IN INTERIOR OF LAMINATE CABINETS TO BE BLACK MELAMINE UNLESS NOTED OTHERWISE.ALL EXPOSED WORK.COMPLY WITH OWNER AND CITY INSURANCE REQUIREMENTS. COORDINATION REQUIRED WITH THE BUILDING MANAGEMENT AND ALL TRADES. : FOUR DIRECTIONS 90 DEGREES APART,AND CONNECTED TO THE MAIN RUNNER WITHIN 2"OF SURFACES TO RECEIVE VENEER OR LAMINATE SURFACE SAME AS FINISHED FACE. THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 _ NCH DESIGN,LLC DBA 4.OWNER:CONTRACTOR TO COMPLY WITH OWNER REQUIREMENTS FOR WORK ON SITE. 4.HAZARDS:IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS ARE ENCOUNTERED, DEGREES FROM THE PLANE OF THE CEILING.PROVIDE THESE LATERAL SUPPORT POINTS 12 MATTER PLANNING+DESIGN LLC DO NOT DISTURB AND IMMEDIATELY NOTIFY THE DESIGNER AND OWNER. : FEET ON CENTER IN EACH DIRECTION,WITH THE FIRST POINT WITHIN 4 FEET FROM EACH WALL. 6.FILLERS:PROVIDE FILLER PANEL AT ENDS OF MILLWORK TYP UNLESS NOTED OTHERWISE.FILLER TO 299 MILWAUKEE ST STE 206 DENVER,CO 80206 5.EXISTNG:ALL EXISTING CONDITIONS AND DIMENSIONS SHALL BE FIELD VERIFIED BY THE : CREATE REVEAL AT MILLWORK AND ADJACENT CONSTRUCTION.REVEAL TO BE FINISHED. 970-379-5401 I www.matterinteriors.com CONTRACTOR,WHO SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES,OMMISSIONS, 5.SALVAGE:COORDINATE SALVAGE ITEMS WITH OWNER PRIOR TO COMMENCEMENT OF DEMO WORK. 2.2:ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM.ATTACH MAIN RUNNER AND CROSS BUSINESS LICENSE 12685 OR CONFLICTS BEFORE PROCEEEDING WITH THE WORK.NO EXTRA COSTS WILL BE AUTHORIZED FOR SALVAGE THE FOLLOWING ITEMS FOR REUSE:DOOR HARDWARE,DOORS,LIGHT FIXTURES,AND : RUNNERS AT TWO ADJACENT WALLS;MAINTAIN CLEARANCE BETWEEN THE WALL AND THE 7.SCRIBE:MILLWORK TO ADJACENT CONSTRUCTION TYPICAL.FILL ALL GAPS WITH PAINTABLE WORK WHICH IS REQUIRED TO COMPLETE THE PROJECT SCOPE AND INTENT DUE TO CONDITIONS SIGNAGE. RUNNERS AT THE OTHER TWO WALLS. SEALANT.MATCH COLOR OF ADJACENT MILLWORK FINISH UNLESS NOTED OTHERWISE. PROJECT TEAM WHICH ARE READILY OBSERVABLE AT THE PROJECT SITE.DESIGN INTENT DRAWINGS ARE DIMENSIONED FINISH TO FINISH OF DRYWALL 6.PROTECT:ALL ITEMS THAT ARE NOT INDICATED TO BE REMOVED(INCLUDING ITEMS TO BE : 2.3:PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES.IN ADDITION,VERTICALLY SALVAGED),SHALL BE CAREFULLY PROTECTED FROM DAMAGE DURING DEMOLITION,AND CAUTION : SUPPORT ENDS OF RUNNERS WITHIN 8 INCHES OF DISCONTINUITIES SUCH AS MAY OCCUR 9.BASE:BASE AT MILLWORK CABINETS TO BE LAMINATE UNLESS NOTED OTHERWISE. NOELLE HERNANDEZ 6.RESPONSIBILTY:THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY CLEANING AND REMOVAL OF SHALL BE USED TO ELIMINATE THE POSSIBILITY OF DAMAGE TO SUCH ITEMS.DAMAGE TO EXISTING WHERE THE CEILING IS INTERUPPTED BY A WALL. NOELLE@MATTERINTERIORS.COM 6 ALL DEBRIS,DUST,AND EQUIPMENT RELATED TO THE DEMOLITION AND THOROUGH CLEAN-UP UPON ITEMS OR SURFACES THAT REMAIN,SHALL BE REFINISHED,REPAIRED OR REPLACED TO THE 6 COMPLETION OF THE PROJECT.PROTECT GROUNDS AND LANDSCAPING WHEN PERFORMING WORK. SATISFACTION OF THE OWNER,BUILDING MANAGEMENT AND DESIGNER AT NO ADDITIONAL COST. : 2.4:SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE 11.GLIDES:PREMIUM GRADE DRAWER GLIDES TO BE FULL EXTENSION TYP.GLIDES AT TRASH DRAWER SORAYA GALLEGO CONTRACTOR WILL BE RESONSIBLE FOR DAMAGE TO GROUNDS AND LANDSCAPING AND BE REQUIRED : ABOVE. CABINETS TO BE EXTRA HEAVY DUTY-200#CAPACITY. SORAYA@MATTERINTERIORS.COM TO REPAIR OR REPLACE AS NECESSARY. 7. COORDINATE:DEMOLITION WITH NEW FLOOR PLAN.CONTRACTOR SHALL VERIFY THE DIMENSIONS AND EXTENT OF DEMOLITION PRIOR TO BEGINING DEMOLITION.CONTRACTOR SHALL COORDINATE 1 3.MATERIALS:CEILING MATERIALS TO BE CLASS 1 OR CLASS A RATED OR BE SUSPENDED FROM 12.GROMMETS:EXACT LOCATION FOR GROMMETS OR OTHER OPENINGS THROUGH THE COUNTERTOP NICOLE STEWART 7.BARRIERS:THE CONTRACTOR SHALL PROVIDE AND MAINTAIN REQUIRED DUST BARRIERS,CANOPIES, LOCATIONS OF NEW OPENINGS WITH THE CONSTRUCTION PLAN. ,GYPSUM BOARD OR OTHER NONCOMBUSTIBLE CEILING MATERIAL WITH MAX GAP OF 1 3/4". TO BE COORDINATED IN THE SHOP DRAWINGS. NICOLE@MATTERINTERIORS.COM BARRICADES,PROTECTION,AND/OR WARNING LIGHTS IN GOOD CONDITION UNTIL THE COMPLETION OF THE WORK REQUIRING SUCH PROTECTION.PROVIDE EGRESS PATHWAYS AS REQUIRED FOR SPACES 9.UTILITIES:CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES PRIOR TO '4.SHOWERS:CEILINGS IN SHOWERS,LOCKER ROOMS,OR OTHER AREAS SUBJECT TO MOISTURE TO 13.HARDWARE:AT CLOSETS,PROVIDE COAT ROD AND SHELF FULL LENGTH OF ROOM.PROVIDE TO REMAIN OCCUPIED DURING CONSTRUCTION. DEMOLITION OF ANY PARTITIONS. ''BE MOISTURE RESISTANT. SUPPORT BRACKETS AT 4'-0"ON CENTER MIN OR AS RECOMMENDED BY MANUFACTURER. 8.HOURS:GENERAL CONTRACTOR TO WORK WITH THE OWNER AND DESIGNER TO DETERMINE WHAT 10.TEMPORARY:PROVIDE TEMPORARY AND PERMANENT SUPPORT AS NECESSARY TO MAINTAIN THE 1 5.ENGINEERING:REFER TO ENGINEERING AND OWNER VENDOR DRAWINGS FOR QUANTITY AND WORK CAN BE DONE DURING WORKING HOURS AND WHAT WORK MUST BE DONE AFTER HOURS ACTIVE INTEGRITY OF ADJACENT AND EXISTING STRUCTURES.THIS INCLUDES BUT IS NOT LIMITED TO :GENERAL LOCATION OF ALL EXIT SIGNS,EMERGENCY LIGHTS,THERMOSTATS,SPRINKLER HEADS,LIFE - DURING CONSTRUCTION. PROVIDING SUPPORT BRACING,FRAMING,LINTELS,BEAMS,AND/OR COLUMNS AS REQUIRED FOR I SAFETY SPEAKERS,DIFFUSERS,ETC.UNLESS NOTED OTHERWISE.COORDINATE EXACT PLACEMENT OF NOTES SUPPORT OF PARTITIONS,BEARING WALLS,WALL OPENINGS,FLOOR OPENINGS,AND/OR BUILDING 'DEVICES WITH ARCHITECT.9.ACCESS:REQUIRED TO BE ACCESSEDCTOR HALL DETERMINE ALL LOCATIONS AND CONDITIONS WHERE WORK IS STRUCTURE. 6.ELECTRICAL:REFER TO ELECTRICAL DRAWINGS FOR SWITCHING AND/OR POWER ZONES.ALL 08. M E P DRAWINGS AND SPECIFICATIONS DESCRIBES THE 12.PATCH:WHERE DEMOLITION OCCURS,ALL REMAINING WALLS ARE TO BE PATCHED,SANDED 'LIGHTING FIXTURES ARE TO BE CONTROLLED/SWITCHED ON THE FLOOR AND/OR FLOOR ZONE LIGHTING GENERAL SCOPE OF THE PROJECT AND DESIGN 10.CORING:ANY CORING REQUIRED THROUGH THE EXISTING STRUCTURAL SLAB TO BE SCANNED. SMOOTH,AND PREPARED FOR FINISHING AS REQUIRED. 'MASTER SWITCH,UNLESS NOTED OTHERWISE. CONCEPT IN TERMS OF THE INTERIOR DESIGN, 1.MEP TRADES:ALL MECHANICAL,ELECTRICAL,PLUMBING,AND FIRE PROTECTION WORK IS TO BE ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND 11.FUMES:WHEN PAINTING OR INSTALLING MATERIALS REQUIRING ADHESIVE SPACES ARE TO BE 13.REPAIR:REPAIR,AND PREP EXISTING WALLS FOR NEW PAINT AND WALLPAPER.SEE FINISH PLAN. i 7.PLACEMENT:THE CONTRACTOR SHALL COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH DESIGN/BUILD.PROVIDE REQUIRED DRAWINGS AND INFORMATION FOR PERMIT.PROVIDE PRODUCT PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT PROPERLY VENTILATED. WHERE DEMO OCCURS,ALL TO REMAIN WALLS ARE TO BE PATCHED,SANDED SMOOTH,&PREP'D FOR i MECHANICAL,ELECTRICAL,PLUMBING,FIRE PROTECTION,AUDIO VISUAL,TELECOMMUNICATIONS,AND DATA AND SHOP DRAWINGS INCLUDING BUT NOT LIMITED TO THE FOLLOWING SCOPE AS NOTED BELOW. NECESSARILY INDICATE OR DESCRIBE ALL OF THE NEW FINISH. 'SECURITY.WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND INSTALLATION,CONSULT THE REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION: WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 12.VERIFY FIRST:THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND BE KNOWLEDGEABLE OF 'DESIGNER BEFORE PROCEEDING WITH WORK. 5 COMPLETION OF THE REQUIREMENTS OF THE CONDITIONS THEREON.CONTRACTOR SHALL INVESTIGATE,VERIFY,AND BE RESPONSIBLE FOR ALL 14.PERIMETER:EXSITING WALLS TO REMAIN UNLESS NOTED OTHERWISE.PREP ALL EXISTING A.DRAWINGS TO INCLUDE BOTH EXISTING AND NEW WORK FOR ENTIRE AREA OF SCOPE. CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, CONDITIONS OF THE PROJECT AND SHALL NOTIFY THE OWNER OF ANY CONDITIONS REQUIRING INTERIOR PARTITION WALLS TO REMAIN TO RECEIVE NEW FINISHES.MATCH ADJACENT FINISHES. i8.LIGHTING:LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES,UNLESS NOTED INCLUDE AREAS OUTSIDE OF PROJECT SCOPE AREA AS REQUIRED TO REFLECT COMPLETE DESCRIBED OR INFERRED,THE CONTRACTOR SHALL MODIFICATION BEFORE PROCEEDING WITH THE WORK. i OTHERWISE.SPRINKLER HEADS AND OTHER CEILING DEVICES ARE TO BE CENTERED IN CEILING TILE SYSTEM. DETERMINE AND INCLUDE IN THE PROPOSALS ALL 15.CUT/CORE:EXISTING FLOOR AS REQUIRED TO INSTALL NEW DEVICES.REFER TO ELEC PLAN FOR 'UNITS AND/OR ALIGNED WITH ADJACENT DEVICES UNLESS NOTED OTHERWISE.REFER TO RCP FOR ITEMS NECESSARY TO PROVIDE THE PROPER 13.LEAD ITEMS:UPON AWARD OF CONTRACT,GENERAL CONTRACTOR SHALL IDENTIFY ALL LONG LEAD DEVICE LOCATIONS. 'LOCATIONS.NOTIFY ARCHITECT OF CONFLICTS BEFORE INSTALLATION. B.PROVIDE AS-BUILT DRAWINGS TO OWNER AND/OR LANDLORD FOR ALL MEPFP SCOPE. EXECUTION AND COMPLETION OF THE WORK. ITEMS(GREATER THAN 8 WEEKS)AND ORDER THEM IMMEDIATELY OR INSTRUCT AND GUARANTEE THAT ' PROVIDE TRAINING FOR NEW SYSTEMS. THE GENERAL CONTRACTOR'S HIRED SUBCONTRACTORS SHALL DO SO. 16.FLOORING:FLOORING AND BASE TO BE REMOVED THROUGHOUT AREA IN SCOPE,UNLESS NOTED i 9.REFENCE ONLY:CEILING PLAN IS FOR REFERENCE ONLY.FIELD VERIFY LOCATION OF ALL EXISTING GENERAL NOTES: OTHERWISE.PREPARE SLAB FOR NEW FLOORING,LEVEL ALL SLAB DEPRESSIONS AND VARIATIONS AS i LIGHT FIXTURES,CEILING GRID AND DEVICES.NOTIFY ARCHITECT OF ANY DISCREPANCIES. C.MECHANICAL-INCLUDE ZONING INFORMATION,LOCATIONS FOR THERMOSTATS,VAV BOXES, 14.SCHEDULE:THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE AND PHASING WITH REQUIRED.CONTRACTOR TO PROVIDE LEVEL FLOOR FOR INSTALLATION OF FINISH FLOOR MATERIALS. AND DIFFUSERS. 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO OWNER'S VENDORS AND SUPPLIERS,SUCH AS FURNITURE,SECURITY,AND TELCOM. PATCH AND REPAIR WALLS AS REQUIRED FOR SMOOTH INSTALLATION OF NEW FINISHES. '10.CONCEALED:CONCEALED DEVICES REQUIRING ACCESS SUCH AS REMOTE BALLASTS,J-BOXES, _ CONSTRUCTION AND/OR FABRICATION. AND HVAC FILTERS ARE TO BE LOCATED ABOVE ACCESSIBLE CEILINGS UNLESS NOTED OTHERWISE. D.ELECTRICAL AND FIRE ALARM-INCLUDE CONDUIT SIZING,CIRCUITING,AND LOCATIONS FOR 15.OWNER:GENERAL CONTRACTOR TO COORDINATE W/OWNER VENDORS 17.MEPFP:DEMOLITION WITH MEPFP DESIGN BUILD DRAWINGS BY GC.CAP ALL REMOVED UTILITIES. ELECTRICAL OUTLETS,TELECOMMUNICATION AND AV ROUGH-INS,LIGHT SWITCHES,LIGHT PULL WIRES BACK TO J-BOX AT DEMOLISHED ELECTRICAL DEVICES. :11. ACCESS:WHERE CONCEALED DEVICES REQUIRING ACCESS CANNOT BE LOCATED AT ACCESSIBLE FIXTURES,FLOOR BOXES. PROJECT 16.DRAWINGS:THE DRAWINGS ISSUED HEREWITH ARE SCOPE DOCUMENTS,AND AS SUCH SHOW THE :CEILINGS,PROVIDE ACCESS PANELS.COORDINATE LOCATION WITH ARCHITECT.ACCESS PANELS ARE GENERAL EXTENT OF THE PROJECT AND DO NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK 18.EXTERIOR FINIHS: 'TO BE CHICAGO METALLIC GRG OR APPROVED EQUAL UNLESS NOTED OTHERWISE. E.PLUMBING-INCLUDE EXISTING AND NEW LOCATIONS FOR PLUMBING FIXTURES AND PIPING. REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE WORK,NOR DO THEY SHOW ALL OF THE A. EXTERIOR STUCCO FINISH AT LOWER LEVEL AND HORIZONTAL AND VERTICAL WOOD SIDING TO INSULATE PIPES. 729 W F RAN C I S ST CONDITIONS WHICH MAY BE ENCOUNTERED TO PROPERLY EXECUTE THE WORK. BE ENTIRELY REMOVED FOR NEW EXTERIOR FINISH. i 12.COLORS:INSOFAR AS PERMITTED BY CODE OR LOCAL AUTHORITIES,ALL LIFESAFETY DEVICES, SMOKE AND CARBON MONOXIDE DETECTORS FIRE PROTECTION- . B. G.C.TO VERIFY EXISTING EXTERIOR BUILDING CONDITIONS AND REPAIR AS REQUIRED IN ORDER :SPRINKLER HEADS,ETC.COLOR AND FINISH ARE TO MATCH ADJACENT CONSTRUCTION UNLESS NOTED F. ASPEN, CO, 81611 17.SCALE DO NOT SCALE DRAWINGS-DIMENSIONS GOVERN.LARGE SCALE DETAILS GOVERN OVER TO KEEP THE INTEGRITY OF THE BUILDING. I OTHERWISE.FINISHES TO BE SELECTED FROM STANDARD COLOR OPTIONS UNLESS SPECIFICALLY SMALL. 19.EXTERIOR HANDRAIL NOTED TO BE CUSTOM. 2.SYSTEMS RECONFIGURE AS REQUIRED FOR NEW LAYOUT.UPGRADE EXISTING SYSTEMS AS 4 A. EXISTING STRUCTURE OF HANRDAIL TO REMIAN.G.C.TO VERIFY EXISTING CONDITIONS AND REQUIRED. 4 18.DESCREPANCIES:WHERE DISCREPANCIES OCCUR BETWEEN THE VARIOUS DISCIPLINES/TRADES, REPAIR AS REQUIRED. i 14.CASEWORK:COORDINATE LOCATIONS OF LIGHT FIXTURES,SERVICE CONNECTIONS,AND OUTLETS CONSULT THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. B. EXISTING WOOD BALAUSTER TO BE REMOVED FOR A DIFFERENT MATERIAL REPLACEMENT. 'LOCATED IN OR ON MILLWORK.COLOR OF DEVICES TO MATCH ADJACENT FINISHES UNLESS NOTED p. AIR BALANCING:AS REQUIRED FOR NEW LAYOUT 'OTHERWISE.COORDINATE COLOR OF DEVICES WITH ARCHITECT. 19.ELEVATIONS:FINISH FLOOR ELEVATIONS ARE FROM TOP OF FINISHED FLOOR,UNLESS NOTED 20.EXTRIOR DECK:TO REMAIN.G.0 TO VERIFY EXISTING CONDITIONS AND REPAIR AS REQUIRED. 4.INSULATION:ALL ROOMS WITH FULL HEIGHT WALLS ARE TO HAVE ACOUSTICALLY INSULATED AND OTHERWISE. ,15.PENDANTS:AT PENDANT LIGHTING,PROVIDE FIELD APPROVAL BY ARCHITECT FOR FINAL OFFSET DUCTWORK(INCLUDING RETURN AIR).VERIFY EXISTING CONDITIONS AND UPGRADE AS PROJECT TYPE 21.EXTRIOR STAIRS:TO REMAIN.G.0 TO VERIFY EXISTING CONDITIONS AND REPAIR AS REQUIRED. :PLACEMENT OF FIXTURES PRIOR TO TRIMMING CABLE LENGTH. REQUIRED. 20.FINISH TO FINISH IMPORTANT:PARTITIONS ARE DIMENSIONED FROM PARTITION FINISHED,UNLESS I NOTED OTHERWISE. 5.RETURN AIR:PROVIDE AIR PATHWAYS TO MAIN AS REQUIRED DUE TO NEW FULL HEIGHT WALLS. INTERIOR ALTERATION 21.PRODUCTS:ARE TO BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND 6.EQUIPMENT:REFER TO EQUIPMENT SCHEDULE FOR PLUMBING FIXTURE SPECS ONLY+ WINDOW - INSTRUCTIONS.ACCLIMATE MATERIALS TO SITE CONDITIONS AS RECOMMENDED BY MANUFACTURER. 22.EXPOSED:ALL EXPOSED SURFACES OF WORK(INCLUDING BUT NOT LIMITED TO,CONSTRUCTION ALTERATION S MATERIALS,PRODUCTS,EQUIPMENT,AND FIXTURES)SHALL BE FREE OF ALL NAME PLATES,LOGOS, '04. PARTITIONS 06. FINISHES ��09. ELECTRICAL & FIRE ALARM STAMPED OR PRINTED MARKINGS,ETC. 1 1 23.PROTECT:EXISTING EXTERIOR WALLS AND OTHER ELEMENTS TO REMAIN THROUGHOUT CONSTRUCTION.FINISH MATERIALS INCLUDING BOTH EXISTING AND NEW SHALL BE PROTECTED 1.PARTITIONS:ALL PARTITIONS ARE ASSUMED TO BE NON-LOADBEARING U.N.O.CONTRACTOR IS '1.CLASS:ALL INTERIOR FLOOR,WALL,AND CEILING FINISHES ARE CLASS 2 AND/OR CLASS B MATERIAL 1.DEVICES:ELECTRICAL OUTLETS,SWITCHES,SECURITY DEVICES ETC ARE TO BE BRIGHT WHITE, ISSUE DURING CONSTRUCTION. RESPONSIBLE FOR CONFIRMING SIZE AND SPACING OF WALL FRAMING TO COMPLY WITH CODE AND 'CLASSIFICATION. UNLESS NOTED OTHERWISE. DEVICES MOUNTED IN DARK COLORED FINISHES SUCH AS BLACK TO BE HEIGHT OF STRUCTURE. BLACK.DEVICES MOUNTED IN STONE OR WOOD SURFACES TO BE GREY DEVICE WITH NO.4 BRUSHED NO. I REVISION DESCRIPTION I DATE 24.BLOCKING:THE CONTRACTOR SHALL FURNISH AND INSTALL ALL BLOCKING,STIFFENERS,BRACINGS, :2.REPAIR:EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES.VERIFY STAINLESS STEEL PLATE.SEE FINISH PLAN OR NOTES FOR ADDITIONAL INFORMATION. 3 BACKING PLATES,AND SUPPORTING BRACKETS REQUIRED FOR THE PROPER INSTALLATION OF ALL 2.BRACING:PROVIDE BRACING ABOVE CEILING AS REQUIRED TYP.PROVIDE HORIZONTAL BRACING AS :EXISTING SUBSTRATES WITH FINISH MANUFACTURER AND TO ENSURE INSTALLATION COMPLIES WITH 3 MILLWORK,CASEWORK,TOILET ROOM ACCESSORIES,TOILET PARTITIONS,INCLUDING WALL-MOUNTED REQUIRED AT ALL CHASE WALLS. I WARRANTY.ENSURE SURFACES TO RECEIVE NEW FINISHES ARE CLEAN,TRUE,AND FREE OF 2.GANG:DEVICES TO BE GANGED TOGETHER TO ONE PLATE WHERE POSSIBLE. 11 IISSUE FOR PERMIT 105/24/2021 I AND/OR SUSPENDED MECHANICAL,ELECTRICAL AND MISCELLANEOUS EQUIPMENT WHETHER SHOWN IN :IRREGULARITIES.DO NOT PROCEED WITH WORK UNTIL SATISFACTORY CONDITIONS HAVE BEEN THE DRAWINGS OR NOT.THIS SHALL ALSO APPLY TO OWNER FURNISHED/CONTRACTOR INSTALLED 3.COMPONENTS:REFER TO SPECIFICATIONS FOR DETAILED INFORMATION FOR PARTITION ASSEMBLY 1 CORRECTED. 3.MOUNTING:REFER TO TYPICAL MOUNTING HEIGHT DRAWINGS FOR MOUNTING HEIGHTS.DEVICES EQUIPMENT. COMPONENTS AND INSTALLATION REQUIREMENTS. I REQUIRED TO BE ACCESSIBLE TO LOCATED WITHIN ADA REACH RANGE.WALL DEVICES LOCATED NEAR 1 3.PAINT:IS TO BE NO-VOC PAINT SUCH AS BENJAMIN MOORE ECO-SPEC OR APPROVED EQUAL. A CORNER ARE TO BE PLACED WITHIN 24"OF THE CORNER TYPICAL. 25.NON EXPOSED:ALL NON-EXPOSED WOOD,PLYWOOD,BLOCKING,SHIMMING,FRAMING,ETC.,TO BE 4.ALL FIRE-RATED:WHERE APPLICABLE PARTITIONS SHALL CONFORM TO THE DESIGNATED TEST :PAINTED SURFACES ARE TO RECEIVE TWO FINISH COATS OF FINISH PAINT OVER ONE COAT OF PRIMER FIRE RETARDANT TREATED. NUMBER.SEE LIFE SAFETY PLANS FOR LOCATIONS OF FIRE-RATED PARTITIONS.FIRE-RATED 11 MINIMUM. 4.UNUSED:EXISTING UNUSED J-BOXES ARE TO BE REMOVED AND WALL PATCHED.BLANKOFF PLATES PARTITIONS SHALL BE CONSTRUCTED PRIOR TO NON-RATED PARTITIONS.BUTT NON-RATED PARTITION I ARE NOT ACCEPTABLE UNLESS J-BOX CONTAINS WIRING. 26.ACCESS:MOVE ALL EXISTING BUILT-IN ACCESS PANELS,HATCHES,AND RECESSED CABINETS TO TO FIRE-RATED PARTITIONS,TYPICAL. :4.PAINTED CEILINGS:ARE TO HAVE FLAT FINISH FACE OF NEW PARTITIONS OR FURRING UNO.PATCH EXISTING AS REQUIRED DUE TO RELOCATED OR : 6.SECURITY:COORDINATE SECURITY DEVICES WITH OWNER AND SECURITY VENDOR.COORDINATE DELETED DEVICES.PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED 5.STC-RATED:WHERE APPLICAALE PARTITIONS SHALL CONFORM TO THE DESIGNATED TEST NUMBER. :5.PRIME:COAT ONLY BEHIND AREAS TO BE COVERED WITH MILLWORK,WALL COVERING,PANELS,ETC. ELECTRICAL ROUGH IN REQUIREMENTS AND DOOR HARDWARE.PROVIDE PATHWAYS FOR SECURITY FOR MECHANICAL,ELECTRICAL,AND PLUMBING EQUIPMENT.ACCESS PANELS SHALL BE CONCEALED SEAL ENTIRE PERIMETER OF ALL STC-RATED PARTITIONS WITH ACOUSTIC SEALANT.AT ALL STC-RATED 11 AREAS BEHIND FILE CABINETS TO BE FULLY FINISHED.PROVIDE FINISH PAINT AT ALL PAINTED AREAS DEVICES AS REQUIRED. AND LOCATIONS REVIEWED BY THE DESIGNER.ACCESS PANELS SHALL HAVE THE SAME FINISH AS PARTITIONS,RECESSED FIXTURES AND OUTLETS SHOULD BE STAGGERED ON OPPOSITE SIDES OF THE I EXPOSED BEHIND ANY MILLWORK,PANELS,CONSTRUCTION,ETC.,DUE TO REVEALS,JOINTS,END ADJACENT SURFACES AND LOCATIONS AT FINISH MATERIALS SUCH AS WOOD,TILE,ETC.ARE TO BE PARTITION ASSEMBLY AND OPENINGS BY A MINIMUM OF 24".FOR SUCH FIXTURES AND OUTLETS :CONDITIONS,ETC. 6.ALARMS:ALL OCCUPIABLE ROOMS AND SPACES REQUIRED TO HAVE AUDIBLE FIRE ALARMS REVIEW CONCEALED AND BE OF THE SAME MATERIAL AS ADJACENT FINISHES. SHOULD BE CAULKED AND SEPARATED HORIZONTALLY 1 EXISTING CONDITIONS AND UPGRADE EXISTING AS REQUIRED TO MEET CODE FOR NEW LAYOUT. '6.BEHIND:ALL PAINTED SURFACES ARE TO BE PAINTED BEHIND ELEMENTS SUCH AS ELECTRICAL 27.WINDOWS:EXISTING WINDOW MULLIONS AND SILLS ARE TO BE PATCHED AND CLEANED AS 6.ACOUSTICS:PROVIDE ACOUSTICAL SEALANT AND INSULATION IN WET WALLS i COVERPLATES,WHITEBOARDS,CLOCKS,SIGNS,ETC.REMOVE EXISTING DEVICES BEFORE PAINTING REQUIRED.REPAIR GAPS AS REQUIRED TO MATCH EXISTING. i AND REINSTALL. 7.MOISTURE PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD AT HIGH MOISTURE AREAS. 28.PARTITIONS:PATCH AND REPAIR TO ACHIEVE/RESTORE FULL COVERAGE AS REQUIRED. PROVIDE CEMENT BOARD AT AT TILE AND WET WALLS AREAS KITCHENS,DISHWASH,SINKS AND '7.EXPOSED:PAINT ALL EXPOSED,BARE,AND COVERED PIPES,DUCTS,HANGERS,STEEL,ELECTRICAL 2 TOILETS. 'BOXES AND CONDUIT TO MATCH ADJACENT SURFACES OR AS SPECIFIED BY DRAWINGS OR FINISH 2 29.GLASS:TO BE AS FOLLOWS UNLESS NOTED OTHERWISE:MIN 1/2"THICK CLEAR TEMPERED AT 1 SCHEDULE.AT CEILINGS,PAINT EXPOSED ELEMENTS FLAT BLACK.PAINT PIPES EXPOSED INSIDE FRAMELESS SHOWERS 8.EXTERIOR:PARTITIONS AT EXTERIOR WALLS ARE EXISTING TO REMAIN :MILLWORK CABINETS.PAINT TO MATCH CABINET INTERIOR COLOR. 30.CORROSION:PREVENT GALVANIC ACTION AND OTHER FORMS OF CORROSION BY INSULATING 9.DOORS:PROVIDE REVEAL DETAILS AS REQUIRED FOR PIVOT AND POCKET '8.WALL FINISH:IS TO MATCH EXISTING UNLESS NOTED OTHERWISE.SMOOTH WALLS TO BE MINIMUM 1 0. PLUMBING METALS AND OTHER MATERIALS FROM DIRECT CONTACT WITH INCOMPATIBLE MATERIALS. 'LEVEL FOUR FINISH TYP.REFER TO PLANS AND MATERIAL SCHEDULE FOR LOCATIONS REQUIRING 10.NEW TO EXISTNG:WHERE NEW PARTITONS MEET EXISTING PARTITIONS AND/OR CONSTRUCTION, i HIGHER LEVEL OF FINISH. PLANNING APPROVALS PARTITIONS SHALL ALIGN W/AND/OR BE LOCATED SIMILAR TO EXISTING PARTITIONS/CONSTRUCTION UNLESS OTHERWISE INDICATED. '9.COVERINGS:TO BE PREPARED FOR MATERIALS. 1.CONNECTIONS:PROVIDE WATER CONNECTION FOR REFRIGERATORS,WATER FILTER,AND COFFEE MACHINES. 02. SUBMITTALS 11.SUPPORT:PROVIDE CONCEALED SUPPORT AND BLOCKING IN PARTIITONS FOR ALL WALL HUNG 10.BASE:WOOD FLUSH WITH DRYWALL AND REVEVEAL DETAIL UNLESS NOTED OTHERWISE. ITEMS.COORDINATE WITH ALL ADJACENT TRADES. , 2.FILTERED:WATER FILTER EQUIPMENT TO BE PROVIDED BY OWNER AND INSTALLED BY CONTRACTOR. _ i 11.PREP FLOORS:AS NECESSARY TO LEVEL IRREGULARITIES IN SLAB IN ACCORDANCE WITH INDUSTRY 12.JOINTS:PROVIDE CONTROL JOINTS EVERY 30'-0"MIN.TYPICAL.REFER TO FLOOR PLANS AND 'STANDARDS. 3.INSULATION:INSULATE EXPOSED PIPING AT SINKS.EXISTING CONDITIONS UPGRADED ATO WATER SUBMITALS AND CLOSEOUT: INTERIOR ELEVATIONS FOR LOCATIONS OF CONTROL JOINTS. ' EFFICIENCY TYPE. 1.SUBMIT SAMPLES OF ALL FINISHES AND FINISHED MATERIALS TO ARCHITECT FOR REVIEW AND1 12.TRANSITION:LOCATIONS AT NEW FLOORING TO BE SCHLUTER SCHIENE OR APPROVED EQUAL APPROVAL,INCLUDING BUT NOT LIMITED TO SUSPENDED CEILINGS,PAINT,WALL COVERINGS,PLASTIC 13.HEAVY FINISHES: HEAVY WALL FINISHES,SUCH AS CERAMIC TILE,AND WALL-HUNG FIXTURES,SUCH U.N.O.LOCATIONS ABUTTING EXISTING RESILIENT FLOORING TO BE SCHLUTER RENO-T OR APPROVED SHEET TITLE LAMINATE,TRIM,GLASS,RUBBER BASE,AND FLOOR COVERINGS. AS LAVATORIES,RDIE CABINETS,ETC.,SHALL NOT BE SUPPORTED IDEON RESILIENTLYWITH MOUNTED WALLS. EQUAL U.N.O. GENERAL NOTES COORDINATE LOCATION OF RESILIENT CHANNEL SIDE OF PARTITIONS WITH ARCH'L DWGS. i 13.CENTERLINE:LOCATE TRANSITIONS IN FLOORING MATERIAL OR COLOR AT CENTERLINE OF DOOR IN 2.SHOP DWGS SUBMIT COMPLETE SHOP DRAWINGS,SCHEDULES,AND PRODUCT DATA TO ARCHITECT CLOSED POSITION U.N.O. 11. MECHANICAL FOR REVIEW AND APPROVAL,INCLUDING BUT NOT LIMITED TO DOORS AND FRAMES AND HARDWARE, WINDOWS,SUSPENDED CEILINGS,CASEWORK,MILLWORK,FLOORING INCLUDING SEAMING DIAGRAMS, 15.EXTEND:FLOORING TO EXTEND UNDER MILLWORK,CABINETS,AND DEMOUNTABLE WALLS UON LIGHTING FIXTURES AND CONTROLS,ELECTRICAL DEVICES,PLUMBING FIXTURES,AND MECHANICAL, i r 1 ELECTRICAL,PLUMBING '17.WATERPROOFING:CURBLESS SHOWERS WATERPROF ENTORE RESTROOM FLOOR. 1.THERMOSTATS:THERMOSTATS ARE TO BE COORDINATED WITH DESIGNER FOR PLACEMENT 1 3.LEFT OVER AT END OF PROJECT PROVIDE THE FOLLOWING MINIMUM AMOUNT OF ATTIC STOCK TO 1 1 18.LABELS:DO NOT PAINT UL LABELS AT DOORS AND FRAMES. 2.TYPE:THERMOSTATS ARE TO BE PROGRAMMABLE NEST BRAND OR SIMILAR. OWNER:ONE FULL GALLON CAN OF PAINT OF EACH COLOR AND FINISH 1 SHEET NUMBER 1 19.SEAL:STONE AND EXPOSED CONCRETE FLOORS ARE TO BE SEALED TYPICAL. 4.AS BUILT SUBMIT TWO HARD COPIES AND DIGITAL PDF FILES OF AS BUILTS,WARRANTY AND 1 OPERATION&MAINTENANCE MANUALS TO OWNER. I G 0 Q CEIVEt /OS/2022 A IB 1C I D IE 1F IG IH IJ 02020 MATTER PLANNINGU DESIGN BUILDING L ARTMENT A I B 1 C I D I E 1 F I G H I J PERCENTAFE OF INTERIOR DEMOLITION PLAN LEGEND DEMOLITION/UPPER LEVEL r/A (IPNOT IN CONTRACT D OUTLET TO BE REMOVED EXISTING INTERIOR FLOOR AREA: 1,355 SF EXISTING OR NIC PARTITION 1 D SWITCH TO BE REMOVED MATT E R DEMOLITION SCOPE OF INTERIOR 0 D DATA TO BE REMOVED NON-LOADBEARING PARTITIONS, OF DEMOLITION WORK AREA D TV CONNECTION TO BE PLANNING 7 PLUMBING AND MILLWORK AREA: 415 SF 7 REMOVED I D E S I G N PERCENTAGE OF DEMOLITION I FLOOR AREA: 31% 017 D THERMOSTAT TO BE EXISTING TO REMAIN OR NIC I REMOVED - - - EXISTING TO BE DEMOLISHED 0 D WALL SCONCE TO BE ER EXISTING TO REMAIN 1 REMOVED D TO BE DEMOLISHED I I DOOR TO BE DEMOLISHED DW DEMO WINDOW 1 EX DOOR-EXISTING TO REMAIN - NCH DESIGN,LLC DBA MATTER PLANNING+DESIGN LLC DD DEMO DOOR WINDOW TAG 299 MILWAUKEE ST STE 206 DENVER,CO 80206 970-379-5401 I www.matterinteriors.com BUSINESS LICENSE 12685 t PROJECT TEAM DEMO PLAN NOTES NOELLEHERNANDEZ A Al B ,` NOELLE@MATTERINTERIORS.COM 6 A GO-04A CT)CO ) - - / G ) O-04A ® ® ) 6 REFER TO SHEET GO-06 FOR ADDITIONAL NOTES l D 5A D / DW7 D APPLIANCE:ALL KITCHEN APPLIANCES TO BE REMOVED. SORAYA@MA TERINTERIORS.COM O rrr2i9: i i�i-iii - - - ��� -_L- - DOORS,DOOR FRAMES&HARDWARE TO DEMO WHERE NOTED D o-as �ti ® fl NICOLE STEWART ni u 0 EX I I i \ i D CO--) • I ELECTRICAL:DEMO AND DISCONNECT WHERE PARTITIONS ARE NICOLE@MATTERINTERIORS.COM _ I DEMOLISHED OR WHERE"D"IS NOTED. IM ELECTRICAL:EXISTING OUTLETS ARE TO REMAIN WHERE NOTED EX. 1 I- OL— 11 n 71- TYP.AT LOWER COVER PLATES TO BE REMOVED FOR REPLACEMENT wz 10 + wz ®® I / \ / \-� 'LEVEL ELECTRICAL:DEMO AND DISCONNECT ALL ABANDON ELECTRICAL - D R'� D DEN,,�r- �-D -� D EX�- CONNECTIONS NOTES III DYJI_-� ELECTRICAL:WHERE EXISTING OUTLETS ARE TO REMAIN:G.C.TO VERIFY DRAWINGS AND SPECIFICATIIONNS DESCRIBES THE j� Imo, D D SE EXISTING WIRING CONDITIONS AND REPAIRAS REQUIRED. GENERALSCOPEOFTHEPROJECTANDDESIGN ii �' - STRUCTURAL:EXISTING TO REMAIN.G.C.TO VERIFY EXISTING CONCEPTINOPEOFTFTHEOJECTORDESIGN, III EX or '' I _ CONDITIONS AND REPAIR AS REQUIRED. ARCHRECTURAL,MECHANICAL,ELECTRICAL,AND I TYP. \ :'_I III PLUMBING SYSTEMS.THESE DOCRUMENTS DO NOT (DW -a �,�IF WINDOW:ALL EXTERIOR WINDOWS TO BE REMOVED FOR REPLACEMENT. NECESSARILY INDICATE OR DESCRIBE ALL OF THE 5 lD IIIL. °❑"' �I EX I „ TYP,AT UPPER WALL EXTERIOR TO BE DEMOLISHED AS REQUIRED FOR NEW WINDOW 5 WORK REQUIRED FOR THE FULLPERFORMANCEAND ® ( ) COMPLETION OF THE REQUIREMENTS OF THE ��\ LEVEL (Z J� , �I /- -\ �-II D II OR DOOR LOCATION. CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, /� 7 IY DESCRIBED OR INFERRED,THE CONTRACTOR SHALL F �� WALL-EXTERIOR-OPENINGS:PATCH AND REPAIR AS REQUIRED WHERE 'irDETERMINE UA INCLUDE PE IN THE HE P O PER ALL n I r-, / /11 E D D D D / IIIDo� IDEMO OCCUR$ DETERITEMS IN ANDE INCLUDE DE PRE PROPER�� t�-//��, 7,..... TYP. Q I TYP. II ®D FIRE PLACE TO BE DISCONNECTED AND REMOVED.PATCH AND REPAIR EXECUTION AND COMPLETION OF THE WORK. 2.1 �,� /`` ' 2.1 ° ��1 u�I ANY WALL OR ROOF PENETRATION DAMGAED BY DEMOLITION. GENERAL NOTES: �� T= 1. wz /, / E co-04A I IIL,/ I I 10\ F_I I SMOKE DETECTOR:TO BE REMOVED AND SALVAGED FOR RELOCATION ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO Dr / \ I L L- D THERMOSTAT:TO BE REMOVED FOR REPLACEMENT. _ CONSTRUCTION AND/OR FABRICATION. - ©Al r _-__� - r- 0 1T -[ FLOORING:ALL FLOOR FINISH TO BE REMOVED THROUGHOUT. +{ F l I D 1 r PROJECT li All f I 00.04B 1A D Li TYP. 4- I� ❑o-q ® D I 1E GO-04A_ II . ex I��� �d� �'®Q r II III D PTV 7CT W FRANCIS ST DI ���I/' / II ° c� I KEYNOTE LEGEND ASPEN, CO, 81611 4 ,,'r' I ® D-1 ELECTRICAL:ALL WALL/FLOOR HEATERS TO BE REMOVED 4 %l / ' '/ ® L K J L J bD THROUGHOUT 3.1 T ❑ ® III __- 1 REF. I7 D-2 ELECTRICAL:ALL WALL SCONCES TO BE REMOVED n we o "�I-r- J �D D-3 ELECTRICAL PANEL TO BE REMOVED FOR RELOCATION u Dex D D D / �� LLJJ D-4 FLOORING:REMOVAL ALL FINISH FLOOR AND WALL BASE PROJECT TYPE _� ,� S CM I THROUGHOUT ODD-oz Zidt -I- /~;�- 1 DCD - D-5 GLAZING SIDELITE AND ASSEMBLY TOBEREMOVED INTERIOR ALTERATION -,I , , ,% r 1 D (6 4 ) D D � CAS-� a� D�°kJ D-6 GLAZING:REMOVED ALL GLASS AT SHOWERS - ONLY+ WINDOW DD-o1 ®®''� //'/ �D�lDrri '� r D D-7 GLAZING:REMOVED VANITY MIRRORS ALTERATIONS D y / lI 1 - EX I I Ir= / D-8 WALL TILE FINISH TO BE REMOVED 01 / ® I I 1 ® L L D-9 CASEWORK AT BATHROOMS TO BE REMOVED cii---� 1 III D-10 CASEWORK AT CLOSETS TO BE REMOVED D-11 CASEWORK AT KITCHEN TO BE REMOVED ISSUE CO - I III 1 i D-12 PLUMBING AT BATHROOMS:SINK,FAUCET,TOILET,SHOWER NO. I REVISION DESCRIPTION I DATE 3 l�-__ D �� .1_ I I I HANDLE/HEAD,TUB,TUB CONTROLS,ETC. TO BE REMOVED 3 GO-04B 1A I % LE ---- D-13 PLUMBING AT KICTHEN:SINK&FAUCET TO BE REMOVED I IISSUE FOR PERMIT I05/24/2021 I TYP. TYP.11 Do- ., Hc , D-14 WINDOW:ALL EXTERIOR WINDOWS TO BE REMOVED I ® III 1 -D - D-15 FIRE PLACE TO BE REMOVED I m D D-16 WALL(EXTERIOR)TO BE DEMOLISHED AS REQUIED FOR NEW / D II FIREPPLACE VENT SYSTEM D I� / I 1 7 I D-17 WALL(EXTERIOR)TO BE DEMOLISHED AS REQUIRED FOR NEW ® , - WINDOW / CZ ■ II 1 D-18 WALL(EXTERIOR)AFFECTED BY WINDOW REMOVAL TO BE PATCH wz ligI ®I TI w� D AND REPAIR AS REQUIRED.NO NEW WINDOW AT THIS LOCATION 1 D-19 EXISTING COLUMN Ex \\ D-20 EXISTING WOOD DECK REMAIN O REMAIN.G.C.TO VERIFY EXISTING LA /� E II 5, - - "sue.® ®* �. - !•� _,� _F- .� /s, ! I. - 5 - CONDITION AND REPAIR AS REQUIRED. DD os TYP. D-36 EXISTING LIGHT FIXTURE TO BE DEMOLISHED FOR REPLACEMENT. 2 EX impm r -c n D-39 EXISTING EXTERIOR STUCCO TO BE ENTIRELY REMOVED,TYP.II 1311 MI 2 G.C.TO�D ®D �'D ®D TYP: CO D CM FINISH. PREP WALL SURFACE AS REQUIRED FOR NEW FACADE D D ■ ! _ _ - L - - - DN \ D-41 EXISTING BALAUSTER TO BE REMOVED FOR REPLACEMENT. HANDRAIL STRUCTURE TO REMAIN.G.C.TO VERIFY EXISTING PLANNING APPROVALS CONDITIONS AND REPAIR AS REQUIRED.PREP SURFACE AS sA I 1El rYP 5A II REQUIRED FOR NEW FINISH GO-04B I Go-04B D-42 EXISTING HORIZONTAL AND VERTICAL WOOD SIDING TO BE y 1 ENTIRELY REMOVED,TYP.G.C.TO PREP WALL SURFACE AS REQUIRED FOR NEW FACADE FINISH. I 1 SHEET TITLE :_______Ar__) DEMOLITION PLAN UNIT 1/ LOWER LEVE & UNIT 2/ UPPER LOWER LVL- DEMOLITION PLAN I ' LEVEL 1 AEXTERIOR WINDOWS & DOORS 1 E UPPER �LVL- INTERIOR DEMOLITION PLAN SHEET NUMBER UP NORTH 0E . IVED ID.° W//2022 A IB 1C ID IE 1F IG IH IJ 0 2020 MATTER PLANNINAStatiN BUILDING DEPARTMENT A I B 1 C I D I E 1 F I G H 1 J PERCENTAGE OF INTERIOR CEILING DEMOLITION CEILING PLAN LEGEND DEMOLITION/UPPER LEVEL EXISTING OR NIC PARTITION .a 0 p WALL SCONCE TO BE EXISTING INTERIOR CEILING AREA: 1,355 SF EXISTING TO REMAIN REMOVED MATTER EXISTING TO BE DEMOLISHED I I RECESSED CAN LIGHT DEMOLITION SCOPE OF INTERIOR TO BE DEMOLISHED PLANNING 7 CEILING AREA: 155 SF Mr 140 SF 7 OF DEMOLITION CEILING k`�`,,,`�y EXISTING WOOD +I D E S I G N PERCENTAGE OF DEMOLITION AREA STRUCTURE TO REMAIN CEILING AREA: 11.5% ER EXISTING TO REMAIN ® EXISTING WOOD CEILING TO REMAIN D TO BE DEMOLISHED ' TRACK LIGHT TO BE I' -{ CELINGARD GYP n n DEMOLISHED NCH DESIGN,LLC DBA O CLG MOUNTED LIGHT TO MATTER PLANNING+DESIGN LLC BE DEMOLISHED 299 MILWAUKEE ST STE 206 DENVER,CO 80206 970-379-5401 I www.matterinteriors.com BUSINESS LICENSE 12685 PROJECT TEAM ic) TAl �C� DEMO CEILING NOTES NOELLE HERNANDEZ 6 III IIII I g I REFER TO SHEET GO-06 FOR ADDITIONAL NOTES 6 NOELLE@MATTERINTERIORS.COM EXISTING WOOD CEILING AND STRUCTURE TO REMAIN.G.C.TO VERIFY SORAYAGALLEGO _ N SORAYA@MATTERINTERIORS.COM EXISTING CONDITION AND REPAIR AS REQUIRED. s� I®i �� a II' I I IIIIII !II_ CEILING DEVICES:REMOVE FOR NEW LAYOUT. NICGLESTEWART Iu WCEILING:G.C.TO VERIFY EXISTING TO REMAIN CEILINGS CONDITIONS NICOLE STEWA RINTERIORS COM I i' AND PATCH AND REPAIR AS REQUIRED. III , LIGHTING:ALL CEILING LIGHTING TO BE REMOVED �� III`. ®7.. 1 rA , _ NOTES :goL ..I 1111111c -ar milli IIII KEYNOTE LEGENDANN CONCEPDRAWINT SCOPE TOERMSFOF EHEWEE INTERIOR DS AND SPECIFICATIONS REDSIGN NIBES E IliTif ill /! it ARCHRECTURAL,MECHANICAL,ELECTRICAL,AND D-2 ELECTRICAL:ALL WALL SCONCES TO BE REMOVED ol p` iiPLUMBING SYSTEMS.THESE DOCUMENTS L,NOT ® DC-1 CEILING:DRYWALL CEILING,LIGHTING AND CEILING FANS AT NECESSARILY INDICATE OR DESCRIBE ALL OF THE '' 11 �I 1• BATHROOMS TO BE DEMOLISHEDWORK REQUIRED FORTHE FULLPERFORMANCEAND S IIII41I.i I cr,111 i ILL IIIIIIII S CONTRACO ON THE R HEFUMENTSORMANa 1 n�i n ., DC-2 CEILING:EXISTING SOFFIT TO REMAIN.REMOVE EXISTING TRIM CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, ICI_r7���/�q��/'1��/�1�/�,..W//// •////////////�h1!%sl AND LIGHTING TO BE REMOVED FOR REPLACEMENT.PATCH, DESCRIBED OR INFERRED,THE CONTRACTOR SHALL 1i ii ifii--- le Ipl In®IIIII F. REPAIR AND SMOOTH SOFFIT A REQUIRED FOR LEVEL 4 FINISH. DETERMINE AND INCLUDE IN THE PROPOSALS ALL ® _ I I 1111111111111111111111111111111111111C r milipill IIII I II ' IIII II E E C TION AND COM LETION FTH PROPER RK.1� II DC-3 CEILING:EXISTING WOOD CEILING TO REMAIN. ExEcuTIONANDcoMPLETIONOFTHEwoRK.IIIIIIIIII IIII I IIII I III ������� IIIIIIIf�III �� �� ��� III IIIII IIII IIII IIIIII INI DC 4 CEILING:EXISTING REPAIR AS REQUIRED P BOARD CEILING TO REMAIN.PATCH AND GENERAL NOTES: lid 'iw -, ///,/ -..0iG-., ///////////ii /.i r p 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO "" I .. r ormiliolliiiimmilimi DC-5 LIGHTING:REMOVE EXISTING TRACK LIGHT MOUNTED ON WOOD CONSTRUCTION AND/OR FABRICATION. © _ I Ill io IIIg11 IIII illl aDipump I/I I I II19 I — STRUCTURE.SALVAGE FOR RELOCATION.REFER TO RCP FOR - IlliII1IIIIIIII1 III III II III II III II IIIIII® rrI ,III !Ili .I NEW LAYOUT. DC 6 LIGHTING TO BE REMOVED,TYP. PROJECT I m ` DC-7 SKYLITE:EXISTING TO BE DEMOLISHED.EXISTING OPENING TO 729 W FRANC IS ST IIIIIIIIIIIIII",,t,.., I I1,,, D BE INFILLED AND TO MATCH EXISTING ROOF CONSTRUCTION. DC-8 CONDUIT TO BE REMOVED ASPEN, CO, 81611 ,, ( D.,,..,.,,,,. I. _ III " ______ I DC-9 SMOKE AND CO DETECTOR TO BE REMOVED AND SALVAGED 4 FOR RELOCATION 4 ® _ 1IIi1Ih�liw II .III.II III IiL III i� III liii 1�1��1� iI I f _ _ DC-11 CEILING:EXISTING FIREPLACE PENETRATION TO BE CLOSE OFF 1111111111111111111111211111111 II III F # [111111111111111111111111III I IIII I IIII I IIII �.I I PROJECT TYPE iirti tillII,'714•. . 1 ,®IcIONLY+ WINDOW III I IIIIIrgi ruirfa INTERIOR ALTERATION 1111 IIIIIII" .11 .D ;'# II -. III ❑ ALTERATIONS II% 7„. ;���ivi�.���/I.r...'.:-.#'I/�//iE:..:t�} %,,., ����. !JI 111101111011111111IIII r Ii�D,- {�I 1. ;,. IIIII I'r. .1.� ISSUE 3 I% .I�// /////% , / :.,'1; ..::D %/////// �//i 3 NO. I REVISION DESCRIPTION I DATE itLjliJJ !Ijffljl. HJII , 1 1 ij Ill LS7°D !In 1111111 a.,"®Ili-�' ''�. Ez .r'J I41 IIIII II Ill I I I s_.._..,I�_ II_I 11 I I Ii Ii it1111111 : :i...i..i AB ., ,,.Ia:. ,I... I 2 2 1 I.J1 PLANNING APPROVALS 0 0 0 0 ❑ ❑ 1 SHEET TITLE DEMOLITION CEILING PLAN UNIT 2/ UPPER LEVEL 1 L 1 E UPPER LVL- DEMO INTERIOR RCP PLAN SHEET NUMBER SCALE: 1/4"=1'-0" NORTH � IVED IDOOE2 a2022 A 1B 1C D 1E 1F I G H IJ ®2020 MATTER PLANNIN SI N BUILDING DEPARTMENT A I B 1 C I D I E 1 F I G 1 H I 3 PERCENTAFE OF PROPOSED CONSTRUCTION PLAN LEGEND _ INTERIOR/UPPER LEVEL EX EXISTING TO REMAIN ////I NOT IN CONTRACT EXISTING INTERIOR FLOOR AREA: 1,355 SF R RELOCATED EXISTING OR NIC PARTITION MATTER PROPOSED SCOPE OF INTERIOR LLD(NEW) LOWER LEVEL DOOR NON-LOADBEARING PARTITIONS, 420 SF 7 PLUMBING AND MILLWORK AREA: 420 SF OF PROPOSED WORK AREA LLW(NEW) LOWER LEVEL WINDOW 7 PLANNING PERCENTAGE OF PROPOSED EXISTING OR NIC PARTITION +I D E S I G N UPW(NEW) UPPER LEVEL WINDOW FLOOR AREA: 31% NEW OR NEW PARTITION UPD(NEW) UPPER LEVEL DOOR j/ MILLWORK (--) DOOR-EXISTING TO REMAIN (oo)- PARTITION TAG LD- NEW LOWER LEVEL DOOR (WEXII- INFILL AT EXTERIOR PARTITION _ NCH DESIGN,LLC DBA TO MATCH EXISTING pD- NEW UPPER LEVEL DOOR MATTER PLANNING+DESIGN LLC WINDOW TAG 299 MILWAUKEE ST STE 206 DENVER,CO 80206 970-379-5401 I www.matterinteriors.com BUSINESS LICENSE 12685 T PROJECT TEAM (C A U W-0A U W-0B Al B U A A U -0B (C) co Qac GO-04C O G 01A 0 N '' 1A EXISTNG N N ,� CONSTRUCTION PLAN NOTES il NOELLE HERNANDEZ N N - BEAM NOELLE@MATTERINTERIORS.COM 6 r (vEXT) EXT- �YEXT) REFER TO SHEET GO-04A FOR ADDITIONAL NOTES 6 i; I SORAYA GALLEGO 1 1/� al ;i __ REFER TO SHEET GO-06 FOR ADDITIONAL NOTES SORAYA@MATTERINTERIORS.COM if- ' —� �-, -- 1 l J �JJJj -- - r BLOCKING:GC PROVIDE AND COORDINATE ALL REQUIRED NICOLE STEWART 1 r ALIGN - -- ALIGN 2- APPLIANCES KITCHEN: NEW REFRIGERATOR,NEW MICROWAVE,NEW NIGGLE@MATTERINTERIORS.COM RAGE/OVEN,NEW DISHWASHER APPLIANCES LAUNDRY: NEW WASHER AND DRYER Iro,".7 � I I CASEWORK:NEW THROUGHOUT BEDROOM 1 �N /777/ B 2_ NLL 209 N DOORS INTERIOR:NEW THROUGHOUT NOTES LL-10 193 SF - -MASTER BEDROOM DOORS EXTERIOR:NEW.REFER TO SHEET GO-04A FOR ADDITIONAL INFORMATION -- __- - - _I 210 I z DRAWINGS AND SPECIFICATIONS DESCRIBES THE zza SF L' - FLOORING:G.C.TO VERIFY EXISTING CONDITIONS AND TO PATCH,REPAIR GENERAL SCOPE OF THE PROJECT AND DESIGN �Ia ^� AND LEVEL AS REQUIRED FOR NEW RADIANT HEAT SYSMTEM. CONCEPT IN TERMS OF THE INTERIOR DESIGN, YJEXT)- - -0- _ ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND a _ i FLOORING:INFLOOR RADIANT HEAT SYSTEM. PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT ` NECESSARILY INDICATE OR DESCRIBE ALL OF THE il WINDOW FLOORING:NEW FLOOR FINISH(OVER RADIANT HEAT SYSTEM)AND WALL WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 Alt I C, y ALIGN BASE.REFER TO FLOOR FINISH PLAN AND ELEVATIONS. 5 COMPLETION OF THE REQUIREMENTS OF THE _ Q ` `_I+N —_—_ _ THERMOSTATS:-NEW AS REQUIRED FOR NEW LAYOUT CONTRACT.ON THE BASIS OF THESCOPE INDICATED, DESCRIBED OR INFERRED,THE CONTRACTOR SHALL -7, !� i" %��� ' O 1 LIGHTING:REFER TO RCP FOR NEW LIGHTING AND CEILINGS DETERMINE AND INCLUDE IN THE PROPOSALS ALL L� i w4 I W3 I ITS ITEMS NECESSARY TO PROVIDE THE PROPER `/I: -,_,, _I C 209-) PLUMBING KITCHEN:NEW SINK AND FAUCET. EXECUTION AND COMPLETION OF THE WORK. 2.1 , LL BATH 2 �' ' 2.1 ` ` I , , 822. sf PLUMBING KITCHEN&LAUNDRY RM:NEW WATER CONNECTIONS FOR GENERAL NOTES: LL-11 P1N-0 . W3) PCORRIDOR REFRIGERATOR AND WASHER&DRYER. ' -® 1E 11 GO-04A - w �I/(o\1, �/ 204 �21°� I 1E GO-04C PLUMBING RESTROOMS:NEW SINK AND FAUCET,SHOWER&TUB I.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO _ ___ IN __ _ 1\�QS/5� a6 SF CONSTRUCTION AND/OR FABRICATION. • r �_-w —�VINDO sf Z11 W4 _ CONTROLS AND DRAINS,TOILETS - �� - - - O BATHRM 2u _ _ _ _- (T) _ _ I ° Exr �i ce�i a zoa 2oa ��I -= WINDOWS:NEW NEW THROUGHOUT.REFER TO SHEET GO-04A&ID-2.1 II w �� 3 0° FOR ADDITIONAL INFORMATION. PROJECT 33 SF i BATHRM 1 ALIGN _ LL-BATH 1 ,( ` ` dial 2m w LNUNDRYCL 211 WALL PARTITIONS:NEW FOR NEW LAYOUT LL-oa 1 w3 Z. 206 1 31 SF Exr WATERPROOF MATERIALS:FOR ALL WET WALLS AND FLOORS IN 729 W FRAN C I S ST �I�. Ilii1 �- -O 17SF 0 p„,., SHOWERS ASPEN, CO, 81611 N I LL=BEDRM 3 / •"• / -- N w W5 (wa) Q ALIGN N STONE/TILE:NEW FOR ALL BATHROOMS AND KITCHEN 4 LL-07 - ` q BEDROOM 2 (w3) (N13 h1 , I k STONE/TILE:NEW FOR FIREPLACE ENCLOSURE 4 WINDOW D2.4 Sf' - 1 207 1 SMOKE&CO DETECTOR:RELOCATED. 3.1 ' — 3.1 122 SF (W3) \ \ /] ❑ / - METALS:STEEL SUPPORTS,FIREPLACE CLADD&MISC BLK'G AS RQ'D LL-MUD RM , 2_0^ MECHANICAL:NEW HOOD KICTHEN PROJECT TYPE GO-04D 1A LL-OS - - ro GO-04D 1A 7E1COAT CL ❑e FIRE RATED MATERIALS:FOR IN WALL BLCKG AND ABOVE CEILING }2-0 ®' �� C —' O° —�E FIRE PLACE:NEW. MANUFACTURER:HEAT&GLO/MEZZO 36"/36 DIRECT 0 7 DR-N qO 1osF ' jW4) I WINDOW VENT GAS FIREPLACE.G.C.TO COORDINATE ON SITE OPENING AT INTERIOR ALTERATION ' /„ N 1, , EXTERIOR WALL FOR PROPER INSTALLATION/VENTILATION. - ONLY+ WINDOW CDR-6) / y W,3 j l NEXT) REFER TO SHEET GO-08 FOR CONSTRUCTION SCHEDULES ALTERATIONS N = / /LL-DIN7VING ® I 2'-0" 4'-0"CLR REF. — gGLAZING:NEW FOR ALL BATHS SHOWERS AND MIRRORS CLEAR HOLD[ ALIGN GLAZING:PROVIDE NEW GLASS BALAUSTER AT EXTERIOR HANDRAIL L RM�NINDOW cz7 ��— ISSUE 4 203 1 KITCHEN Qa 01 5j- Lw-0 (,N2) 297 SF 202 0 KEYNOTE LEGEND NO. REVISION DESCRIPTION DATE 1sz sF 1 ELECTRICAL:RELOCATED ELECTRICAL PANEL 3 3 LL-LIVING RM LL-LAUNDRY N DLL-01 .,/ / LL-04 1 2 NEW FIRE PLACE:MANUFACTURER:HEAT&GLO/MODEL:36"MEZZO/ 1 TISSUE FOR PERMIT 05/24/2021VESTIBULE�I I w zo1 36 DIRECT VENT GAS FIRPLACE ti �l �— — a2 sP 3 FLOORING:NEW WOOD FINISH FLOOR OVER NEW FLOOR RADIANT CLG \ HEAT SYSTEM,TYP. JOIST ALIGN °w a -�� 4 FLOORING:NEW TILE FINISH FLOOR OVER NEW FLOOR RADIANT LL (wz) - J HEAT SYSTEM. 1 WINDOW 5 NEW BLACKENED METAL PLATE CANOPY BELOW.PROVIDE N pro I LL-MECH CONCEALED SUPPORT AS REQUIRED. LL oo WINDOW ALIGN 6 REFER TO STRUCTURAL ENGINEER DOCUMENTS FOR NEW OPENING w cn ALIGN ALIGN ' 9L.6 7 NEW METAL SCREEN 1 FLOORING:NEW CARP ET PET FINISH FLOOR OVER NEW FLOOR RADIANT TYP 5 : 1 I 5) - 1 N HEAT SYSTEM,TYP. [LDR-o'� LDR-0 N PDR-0 _I N ��N EXT KrPDR-01 1'tPDR-0�1' EXT 2 N N 2 ❑e ❑ DN ❑ _ I■ ... .-' : ' "- MMS1 ,,, EXISTING DECK PLANNING APPROVALS i I I I I I 200 I 402 SF I I 1 1 1 GL6 _ I I 1 1 TYP 0 0 0 ❑ - -. II 1 I v --,.. 11 I II SA I SA GO-04D I I I I GO-04D SHEET TITLE 11 FLOOR PLAN II II LOWER LEVEL- EXISTING PLAN NEW ' II 1 1 AEXTERIOR WINDOWS & DOORS 1 E UPPER DLVL- FLOOR PLAN 1 SHEET NUMBER UP NORTH E . IVED o-0 • /2022 A I B I C I D I E I F I G IH 1J ®2020 MATTER PLANNING SIGN BUILDING DEPARTMENT A I B 1 C I D I E 1 F I G H I J REQUIREMENT: PERCENTAGE OF PROPOSED CEILING PLAN LEGEND INTERIOR CEILING/UPPER LEVEL v/A NOT IN CONTRACT 1, PAINTED GYPSUM BOARD MATT E R AT LEAST 75%OF LIGHTING WILL BE HIGH EXISTING INTERIOR CEILING AREA: 1,355 SF - CEILING/LEVEL 5 FINISH EFFICACY. EXISTING OR NIC PARTITION PROPOSED SCOPE OF INTERIOR 1307 SF EXISTING WOOD CEILING PLANNING 7 ACTUAL:34 OF TOTAL PERMANENT FIXURES CEILING AREA: 1,307 SF MI OF PROPOSED CEILING TO REMAIN 7 + D E S I G N (LT-01)ARE HIGH EFFICENCY(100%). WORK AREA PERCENTAGE OF PROPOSED \\�\\\ HIGH EFFICCY LAMPS ARE DEFINED BY 2009 IECC CEILING AREA: 96.5% � EXISTING WOOD 202 AS: EXISTING OR NIC PARTITION STRUCTURE TO -60 LUMNES PER WATT FOR LAMPS OVER 40 NEW OR NEW PARTITION REMAIN WATTS. -50 LUMENS PER WATT FOR LAMPS OVER 15 EX EXISTING TO REMAIN a KEYNOTE TAG WATTS TO 40 WATTS. -40 LUMENS PER WATT FOR 15 WATTS OR LESS LT-)GC LIGHT FIXTURE TAG (CLG-19)( CEILING TAG - NCH DESIGN,LLC DBA MATTER PLANNING+DESIGN LLC 299 MILWAUKEE ST STE 206 DENVER,CO 80206 970-379-5401 I www.matterinteriors.com BUSINESS LICENSE 12685 t PROJECT TEAM 9S) ER ER C4) LIGHT FIXTURES SYMBOLS NOELLE HERNANDEZ NOELLE@MATTERINTERIORS.COM 6 1 1 r 1 I 0 RECESSED LIGHT FIXTURE 1 0- WALL SCONCE WALL SCONCE 6 SORAYA GALLEGO 0 SIU RFA EE MOUNTED LIGHT SORAYA@MATTERINTERIORS.COM *� _—_ �I-_1- _ 1 ---- SURFACE MOUNTED TAPED LED A / — — �' 1 o WALL MOUNTED LIGHT NICOLE MATTET _ / �EX 1 _ FIXTURE SMOKE AND CO DETECTOR NICOLE@MATTERINTERIORS.COM w LT SS' MASTER BEDROOM 1 9 �9 11 f':; -EX Ea 1v LT-05 I 210 I POWER&DATA PLAN LEGEND ;IL" r + LT 01 �f EX ❑ ® ,ELT-01 I. �r - - LT-01 LT-01 LT-01, ',✓ 9 OUTLET ® FLOOR OUTLET `F' TV LOCATION d 1 1 CLG-g I r I , NOTES 2..- VARIES v i i ' I EX PGFI GFI OUTLET $ SWITCH 4 THERMOSTAT CLG•3 k I i DRAWINGS AND SPECIFICATIONS DESCRIBES THE BEDROOM 1 ❑-' _ I LT-01 209 I '-Cr) ¢ & BEDROOMI I®, GENERAL SCOPE OF THE PROJECT AND DESIGN ILT 01 LT 01 BED II y i , LT-01 CONCEPT IN TERMS OF THE INTERIOR DESIGN, I I I 209 1 ea ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND -•I LT 01 LT-01 "-, '' _I L-01 T-01 CEILING PLAN NOTE$ PLUMBING SYSTEMS.THESE DOCUMENTB DO NOT tEXT i L ¢T Ti.�.�. o- ,_ • ; CD,, ,�--' i NECESSARILY INDICATE OR DESCRIBE ALL OF THE 5 WINDOW EQ EQ MASTER BEDROOM REFER TO SHEET GO-06 FOR ADDITIONAL NOTES 5 WORK REQUIRED FOR THE FULL PERFORMANCE AND ' :..1 210 I. ��� �: ii COMPLETION OF THE REQUIREMENTS OF THE o\ CEILING:NEW DRYWALL CEILING FLAT PLASTER FINISH TO BE LEVEL 5 CONTRACT ON THE BASIS OF THE SCOPE INDICATED, EO EQ LT 01 E-s -- , LT-01 L } Y E WHERE INDICATED DESCRIBED OR INFERRED THE CONTRACTOR SHALL ______ _ I LT-OS - - LT-OS i DETERMINE AND INCLUDE IN THE PROPOSALS ALL EQ EQ„ EQ -•EQ __ CEILING:NEW DRYWALL SLOPED CEILING PLASTER FINISH TO BE LEVEL 5 ITEMS NECESSARY TO PROVIDE THE PROPER [ 221 - — — Q I ,, < — WHERE INDICATED EXECUTION AND COMPLETION OF THE WORK. LIGHTING:NEW RECESSED LED DOWNLIGHTS WHERE INDICATED GENERAL NOTES' ® c c a LT os C w° J �Lr 01 %9 - LT-os _FI r-o1 D' LIGHTING NOT SHOWN IN DRAWINGS ARE DECORATIVE AND SURFACE :' ii - I Ea ra 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO I'L 01 LT-01 MOUNTED .: ",_ - ,LT-01 � � — CONSTRUCTION AND/OR FABRICATION. CORRIDOR �,t, _ MECHANICAL:NEW CEILING EXHAUST FANS AT BATHROOMS U Of-Cs-. 2 �T!7. DOOR Ii CSC. E-s ., BATHRM 2 J - BATHRM 2�LT-01 CORRIDOR E-s • I r SMOKE&CO DETECTOR:RELOCATED.MATTER TO PROVIDE NEW w EQ EQ ., 1 _�_I 1 I1 CJCu ���"`®®®T-04 PROJECT i 8-2' b' .. --\ LAUNDRY CL i ,CLG a" w ®I 205 BATTERIES AS REQUIRED. LTI01 208 ._ ❑ d I" r o1 Lr oa 0 206 I LT o1 I zoo I B ALL RECESSED LIGHT FIXTURES TO BE IC RATED BENEATH THE THERMAL 729 W FRAN C I S ST �Li-o1 BATHRM 1 ENVELOPE,TYPICAL THROUGHOUT I r I r FX Es' ASPEN, CO, 81611 LT 01 DOOR BATHRM 1 E a__ El �, LT-01 _ // ,� 1 211 1 CLG 3" BEDROOM 2 ., LAUNDRY CL O 1 211 - I I I 9{ rpFl--ry/ POWER/DATA NOTES 4 207 I LT 04-4 - IEr `�m JJJ 1-1 -�� 4 �LT-oa ALL COVER/SWITCH PLATES FINISHES TO BE COORDINATED W/MATTER. 3.1 i EQ EQ dr. o. I \; APPLIANCES: NEW OUTLETS FOR ALL APPLIANCES 31 �' ' d cLG z ° w BEDROOM z cony cL �� I CASEWORK LIGHTING:UNDER,ABOVE&IN KITCHEN z o - 6 2 EQ EQ 7;Q7° 207 zos a ,' •I� LT-01 , LT-01 PROJECT TYPE to ELECT: REPLACE COVER PLATES WHERE "EX"IS INDICATED. - '1:. 1 EX - n) I L.' -y ® 0 — '� v LT 01 d LT 01 LT 01 01 DOORF r w. . ry �I -LT 01- LT-01 LT-oi ELECT: GC PROVIDES FOR NEW LAYOUT AND TO BE INSTALLED PER CODE 4 L7o1 d ®J 8L 21 EQ. EQ ._ _—_ 4 _L- - -_ _ LT01 __ J _ _ I __ _ _.�_ _ _ ELEC: PROVIDE GFI OUTLETS AT WET AREAS INTERIOR ALTERATION ,)-• :9: 1 O 9 '59 —oT \ 9 FLOOR HEAT RADIANT SYSTEM(NEW) - ONLY+ WINDOW r COAT uK1716HEN :11 # d ® LIGHTING:NEW LIGHTING AND DIMMING THROUGHOUT ALTERATIONS LT 08B - LT-08B REF. 1 I / ELECTRICAL PANEL TO BE RELOCATED AS INDICATED IN DRAWINGS. 1 L_zos_f �` _ i I ® 1 EX , IN -FI ELECTRICAL PROVIDE POWER FOR NEW CEILING FANS EQ a EQ EQ EQ EQ k EQ 1 a 3 e l ``` PROVIDE NEW THERMOSTAT M E) O 1 Z5 �5 Ic, ,_ - PROVIDE POWER FOR KITCHEN VENTILATION HOOD ISSUE EQ EQ o1 LT 01? Lr or. T-01 Lr o1 r-01 LT-o1 01 LT-OP ELECTRICAL:OUTLETS TO BE O.C.15"A.F.F.MOUNTED,UNLESS NO. I REVISION DESCRIPTION I DATE on LT-01 LT 01 LT 01 KITCHEN _ _ 3 - I �� o i -� �:_ " �, 1 ® i o - - OTHERWISE NOTED 3 I` ) ® LIVING RM ® ^II ELECTRICAL:OUTLETS ABOVE COUNTERTOPS TO BE O.C.44"A.F.F. I1 'ISSUE FOR PERMIT 105/24/2021 I LIVING RM ( ' I 203 1,-' .I■ �" �i aF I LT ocLc 2. LT-o1 MOUNTED,UNLESS OTHERWISE NOTED 203 I d'i ¢ - -I d s 9- 0- / ,'k ¢ ' ® i� VESTIBULE IILT 01 F'' I-,- -:.LT-09 I w LT-01 LT-09 201 S - — r } ) Ox O ( ell ®IIo_r-+ EYNOTE LEGEND FIREPLACE ,.!T 07 1 1' 0,h S LT-07 01u - Wit ' � LT-o1� I J el �. E C-3 BATTERY SMOKE&CO DETECTOR LOCATION ABOVE DOOR FRAME ® 3 s ) w Jr c s I ‘.® I_ o C-4 BATTERY SMOKE&CO DETECTOR LOCATION Lr o7 I C-5 CEILING EXHAUST FAN LOCATION ���JJJ Ei ��LLJJ C-7 NEW SLOPED DRYWALL CEILING.LEVEL 4 PLASTER PAINTED FINISH. • -I �ESTBUL4 -- _-�___ -_____---- C-8 FLAT DRYWALL CEILING.LEVEL 4 PLASTER PAINTED FINISH. 20 5- d5 1 C-9 SURFACE MOUNTED LIGHT LOCATED WHERE EXISTING WAS LT-01 LT Otji j j ',:::':"."-:'•I'.-, .-',.j-',.z;....:':-.:"' ` LT-01 �c,,,, .LT-01 LT-01 E`H'11 �P I l REMOVED 5;(— �-_ C-10 JUNCTION BOX FOR DECORATIVE PENDANT —9I - - - - z1 Jj C-11 SURFACEMOUNTEDTAPEDLEDLIGHTFIXTUREATXISTINGAND2NEW DRYWALL SOFFITC-12 NEW COVED SOFFIT TO MATCH EXISTING.PROVIDE NEW PAINT -- /�//� /� � ' � �J L - v I DN FINISH. C-13 EXISTING COVED SOFFIT TO REMAIN-PROVIDE NEW PAINT FINISH- PLANNING APPROVALS EXISTING DECK E-1 ELECTRICAL PANEL-RELOCATED LOCATION 200 1 E-2.1 CONVENIENCE OUTLET FOR REFRIGERATOR AT 15"A.F.F. E-2.2 CONVENIENCE OUTLET FOR DISHWASHER AT 15"A.F.F. E-2.3 CONVENIENCE OUTLET FOR MICROWAVE E-2.4 CONVENIENCE OUTLET FOR RANGE/OVEN E-3 CASEWORK LIGHTING E-4 SWITCH/DIMMERS FOR SURFACE MOUNTED AND DECORATIVE SHEET TITLE LIGHT FIXTURES RCP & POWER/DATA E-5 SWITCH/DIMMERS FOR RECESSED LIGHT FIXTURE FLOOR PLANS E-6 SWITCH FOR CEILING FAN E-7 FLOOR OUTLET PLANS 1 E-8 TV LOCATION WITH RETRACTABLE ARM.PROVIDE BLOCKING AS 1 /� REQUIRED. A 1 UPPER LVL- RCP PLAN E UPPER LVL- POWER PLAN SHEET NUMBER SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0' NORTH 10-01 90.'CC VE® 2 022 A I B 1 C I D I E 1 F I G I H 1 J �i ©2020 MATTER PLANNINARMN BUILDING DEPARTMENT A I B 1 C D 1 E 1 F I G H I J FINISH FLOOR PLAN LEGEND k/ NOT IN CONTRACT MATT E R EXISTING OR NIC PARTITION PLANNING 7 7 +IDESIGN EXISTING OR NIC PARTITION NEW OR NEW PARTITION o- KEYNOTE TAG NCH DESIGN,LLC DBA MATTER PLANNING-,DESIGN LLC 299 MILWAUKEE ST STE 206 DENVER,CO 80206 970-379-5401 I www.matterinteriors.com BUSINESS LICENSE 12685 //���� PROJECT TEAM Al (C A Al L J WOOD FLOOR FINISH OVER \h INFLOOR RADIANT HEAT SYSTEM NOELLE HERNANDEZ 6 - T _ - - - - — i T 1 i I WD.1 1 6 NOELLE@MATTERINTERIORS.COM O —1- -I .... _ _ = - - II SORAYA GALLEGO CARPET FLOOR FINISH OVER SORAYA@MATTERINTERIORS.COM II — - - in ' ■_' ''''''''''' r n. n .. .... .,I - -Ill ■ INFLOOR RADIANT HEAT SYSTEM �I _______________ I I NICOLE STEWART CPT-1 NICOLE@MATTERINTERIORS.COM 1______ I I naa. TILE FLOOR FINISH OVER INFLOOR om ------ ------------------- RADIANT HEAT SYSTEM ____ ______________ BED ------------- _-_-_-_-_-_-_-_-_- NOTES _-- _ EXISTING WOOD DECK TO - 1 r G REMAIN DRAWINGS AND SPECIFICATIONS DESCRIBES THE - .1Exw. GENERAL SCOPE OF THE PROJECT AND DESIGN "-'- BED '------------ - CONCEPT IN TERMS OF THE INTERIOR DESIGN, MASTER BEDROOM I .I BEDROOM 1 MASTER BEDROOM - ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND Ir- --'''' - PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT ___________I209 -_-1-210 ___ I 209 __ 210 NECESSARILY INDICATE OR OJECRIBEALESI THE 5 __________________- I -- CP7.1 CP7.1 NOTES: 5 WORK REQUIRED FOR THE FULL PERFORMANCE AND R R E D _____________------------ - - -REFER TO SHEET GO-O6 FOR ADDITIONAL INFORMATION. COMPLETION OF THE REQUIREMENTS OF THE I - - - - -_-_- -_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_- II ______ _ CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, i i - -__ --__-- DETERMINE AND INCLUDE IN THE PROPOSALS ALL -- 1 - ITEMS NECESSARY TO PROVIDE THE PROPER { EXECUTION AND COMPLETION OF THE WORK. 12.1 OMI N 1 I GENERAL NOTES: 1 CORRIDOR I� I CORRIDOR 0 ___ J(�0�� 204 _ 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO ____- ___ I 1\ /i - — - - ___ ______ - CONSTRUCTION AND/OR FABRICATION. WD.1 IllIBATHRM 2 -- - I BATHRM 2 -f 'a 208 "u„'�_ ! I I — —a���`_ tall) 1 208 I ■_I I F I PROJECT 1 INISH FLOOR PLAN NOTES ihniIII+YIM_ I / 1 BATHRM 1! I ® _ 1 REFER TO SHEETS 00 06 AND GO-OS FOR ADDITIONAL NOTES _ I I \ ®LAUNDRY C n O \LAUNDRY C BATHRM 1 2 REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL MATERAIL INFORMATION AND DETAIL �aI 205 211 3 ALL WALLS ARE TO PAINTED LEVEL4,UNLESSNOTEDOTHERWISE729 W FRANCIS ST BEDROOM 2 I I 1 111111"111111 ""' I BEDROOM 2 �-WD.1 T.1 4 ALL WALLS AT BATHROOMS TO PAINTED LEVEL 5 UNLESS NOTED OTHERWISE ASPEN, CO, 81611 IIll 207 IIIII® I II _ �� 5 FLOORS:NEW WOODFLOOR THROUGHOUT,INLESSOTHERWISE NOTED J- 6 FLOORS:NEW TILE FLOOR AT BATHROOM LOTIONS 4 1 " I ® —1 '/ r��I - 7 TILE WALLS:NEW AT SHOWER,TUB AND WETALL LOCATIONS 4 n __ __ 1. 'II_ I 3 I \ I 8 INSTALL WALL BASE TILE AT ALL FLOOR TILECATIONS .14 /I 9 INSTALL WOOD BASE AT ALL WOOD FLOOR LOCATIONS BTHRM 1 SHOWER TOILET RM1 10 WOOD FLOOR TO BE INSTALLED PER MANUF.RECOMMENDATIONS.PROVIDE A WOOD QUEEN SIZE1 25 212 THRESHOLD AT DOORWAY,LOCATE TRANSITION AT CENTERLINE OF CLOSED DOOR 213 . 11 REFER TO CEILING PLAN FOR CEILING FINISHES PROJECT TYPE BED COAT CL I. COAT CL ///��� -- T 1 I�1_\ 2 EXISTING EXTERIOR DECK TO REMAIN AND TO BE REFINISHED. QIIII. LVJ INTERIOR ALTERATION '206 206 / �1 W I61j _:,I 3 ONLY+ WINDOW rill REF �\ ALTERATIONSil r-\ - I II I II ' ' LIVING RM- LIVINGRM- '' 203MN�1 III KITCHEN — 203 KITCHEN ISSUE �IppM_202IiR II - - WD 1 - - 202 IIeP_ Na REVISION DESCRIPTION DATE il 3 I 1� �� J4 I _ I - --� 3 III' (® ®II �� II � GCS\ VESTIBULE el II lin ,I I : , 1 C 201 I - if , . ::til '�,�7-1 1 WD.1 ,, I 1 r _ -._ 1 11 Pil .... . ILA1L1111r II II- III 1 . _ jwi_____I- i, il . , © LEI _511- l'ill _ _ -- _-_ _.- Ra 2 2 LI II II I - - - - - DN \ - DE EXISTING DECK EXISTING DECK PLANNING APPROVALS I 200 1 200 1 I all 1 EXWD 1 SHEET TITLE FINISH & FURNITURE FLOOR PLANS 1 UPPER LVL- FURNITURE PLAN 1 1 AFOR REFERNCE ONLY 1 E UPPER LVL- FINISH PLAN SCALE: 1/4" /4"=1-!)° SHEET NUMBER I NORTH 1 E IVED D-0 • ,. /2022 A IB 1C ID IE 1F IG IH IJ 02020 MATTER PLANNINASEE N BUILDING DEPARTMENT A I B 1 C I D I E 1 F I G 1 H I J EXISTING EXTERIOR I r MATTER WALL ASSEMBLY j � EXISTING EXTERIOR / WALL ASSEMBLY r, / PLANNING 7 EXISTING SHEATHING j / EXISTING SHEATHING i/ 4 / + D E S I G N NEW WOOD WORK FRAME �q�,/,.; / NEW METAL FRAMING II/�� / ATTACHED TO EXISTING / ATTACHED TO EXISTING �i EXTERIOR SHEATHING / �/- / EXTERIOR SHEATHING �� / NEW WOOD j j / "I ��. BATTENS BEYOND / / NEW STANDING SEAM j j / METAL ATTACHED TO / / METAL FRAMING WITH �� _ NCH DESIGN,LLC DBA NEW WOOD VERTICAL / / CONCEALED FASTENERS — y SIDING ATTACHED TO MATTER PLANNING+DESIGN LLC WOOD WORKFRAME .. / / LW 299 MILWAUKEE ST STE 206 DENVER,CO 80206 WATERPROOF MEMBRANE 1'_ / 970-379-54011 www.matterinteriore.com WATERPROOF %—�/ �I j " / BUSINESS LICENSE 12685 MEMBRANE f / FLASHING ' .1i � ./ / PROJECT TEAM FLASHING �� / �% NOELLE HERNAN D EZ 6 I �® / 6 NOELLE@MATTERINTERIORS.COM ERIORS.COM w wz— C a w z SORAYA GALLEGO SORAYA@MATTERINTERIORS.COM EXISTING SOIL a 11 _ 1*fi - NICOLE STEWART OR PAVING z a - EXISTING SOIL 0 Z o. 0 OR PAVING g - FLASHING TO BE NICOLE@MATTERINTERIORS.COM e O FLASHING TO BE p \ EXTENDED 6"BELOW \ `v , EXTENDED 6"BELOW 11 III 0 I .. a GRADE ,N. —— GRADE —III—I I - I I— ': ..4,- a —I I—III '`6.- :} — III O III EXISTING 1 I—III—_m 0 I I— I NOTES —IIII I d _ FOUNDATION —I I —I I I-fO I I • EXISTING —III— - III I I '• FOUNDATION DRAWINGS AND SPECIFICATIONS DESCRIBES THE III _ _a GENERAL SCOPE OF THE PROJECT AND DESIGN —III—III—III—III— -./I0.' —III-1 I I—I I 1-1 I I ..% CONCEPT IN TERMS OF THE INTERIOR DESIGN, \9 ARCHITECTURAL,MECHANICAL,ELECTRICAL,AND PLUMBING SYSTEMS.THESE DOCUMENTS DO NOT NECESSARILY INDICATE OR DESCRIBE ALL OF THE WORK REQUIRED FOR THE FULL PERFORMANCE AND 5 EXTERIOR DTL SCT AT WD SIDING EXTERIOR DTL SCT AT STANDING 5 COMPLETION OF THE REQUIREMENTS OF THE CONTRACT.ON THE BASIS OF THE SCOPE INDICATED, 5 EAND EDGE OF SLAB 5 H SEAM METAL AND EDGE OF SLAB DESCRIBED ANDOR INCLUDEFERRED, ECONTPOSALSRACTOR SHALL v DETERMINE AND INCLUDE IN THE PROPOSALS ALL ITEMS NECESSARY TO PROVIDE THE PROPER SCALE: 3"=1'-0" SCALE: 3"=1'-0" EXECUTION AND COMPLETION OF THE WORK. GENERAL NOTES: 1.ALL DIMENSIONS TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION AND/OR FABRICATION. — 111111 PROJECT 729 W FRANCIS ST II ASPEN CO 81611 IT III 4 4 WALL FINISH IIII III y DOOR U 1. DOOR 1 U DOORy DOOR OPENING WIDTHWALL FINISH RE:SCHEDULE DOOR DOOR RE:SCHEDULE b ) } } OPENING WIDTH OPENING WIDTH OPENING WIDTH DOOR HEAD OPENING WIDTH OPENING WIDTH I I 1 I I DOOR HEADRE:STRUCTURAL I III PROJECT TYPE _ _ = i i RE:STRUCTURAL DOOR II� „ III w o 0 0 HARDWARE �ii.'—I— INTERIOR ALTERATION SHIM SPACE -- �- = ONLY+ WINDOW — g �=, z �� �: �A �A �A �A SHIM SPACE w ALTERATIONS 0 �r O O O O O =/ WOOD TRIM,STAINED O O 0 0 > 0 0 > WOOD TRIM,STAINED f---� 0 0 0 a 0 0 J DOOR RE:DOOR SCHEDULE �/ - } DOOR RE:DOOR SCHEDULE - f W/ ISSUE D1 SSINGLE FLUSH WING DOOR DZ PAIR DOOR GLASS SWING D3 GLASS DOOR AT SHOWERD4 POCKET DOOR D5 EGLASS TRY LITE DOOR W/ D6 SLIDING GLASS DOOR T! NO. I REVISION DESCRIPTION I DATE 3 3 INTERIOR INTERIOR INTERIOR INTERIOR EXTERIOR EXTERIOR TYP DETAIL SECTION DTL DETAIL SECTION AT DOOR TYPES 3 G AT DOOR FRAMES 3 H POCKET DOOR BGALE:1/4"=1'-0" SCALE: 3"=1'-0" SCALE: 3"=1'-0" 2 44 4 - - 4 . .. A. !c-.:,,, 2 1)1/ 18I111 1 1/ a �1r,���1�/////// �/�/� // PLANNING APPROVALS PARTITION TYPE AS I i ... ��I TAGGED ON FLOOR 1 — -- - - - P PLANS WET BOARD WET WALL SIDE WET BOARD) WET WALL SIDE lai DESCRIPTION: NON-RATED/NON-LOADBEARING PARTITION DESCRIPTION: NON-RATED/NON-LOADBEARING PARTITION DESCRIPTION: NON-RATED/NON-LOADBEARING PARTITION DESCRIPTION: NON-RATED/NON-LOADBEARING PARTITION WOOD STUD ANCHORED WOOD STUD SIZE(S): 2 X 6 @ 16"O.C. WOOD STUD SIZE(S): 2 X 4 @ 16"O.C. WOOD STUD SIZE(S): 2 X 6 @ 16"O.C. WOOD STUD SIZE(S): 2 X 4 @ 16"O.C. I.�I III TO FLOOR SLAB GYPSUM BOARD:1 LAYER(S)@ 5/8" THICK GYPSUM BOARD:1 LAYER(S)@ 5/8"THICK GYPSUM BOARD: 1 LAYER(S)@ 5/8" THICK GYPSUM BOARD:1 LAYER(S)@ 5/8" THICK ACOUSTICAL SHEET TITLE l SEALANT WET BOARD: 1 (ON WET WALL LAYER(S)@ 1/2" THICK WET BOARD: 1 (ONWA WET LAYER(S)@ 1/2"THICK GYPSUM BOARD: 1 LAYER(S)@ 5/8 THICK GYPSUM BOARD:1 LAYER(S)@ 5/8" THICK BOTH SIDES, SIDE) WALL SIDE) INSULATION: FIBER GLASS BATT TYPE@ 31/2"THICK INSULATION: FIBER GLASS BATT TYPE@ 31/2"THICK DETAILS BK6(�IFINISH AND BASE INSULATION: FIBER GLASS BATT TYPE @ 3 1/2" THICK INSULATION: FIBER GLASS BATT TYPE @ 3 1/2" THICK FIRE RATING: N/A TEST NUMBER:N/A FIRE RATING: N/A TEST NUMBER: N/A PER FINISH >nl'ii�n FIRE RATING: N/A TEST NUMBER: N/A FIRE RATING: N/A TEST NUMBER: N/A 1 1 SILL DETAIL - TYPICAL PARTITION TYPE - W6 PARTITION TYPE - W5 PARTITION TYPE - W4 PARTITION TYPE - W3 SHEET NUMBER SCALE: 3"=1'-0" SCALE: 3"=1'-0" SCALE: 3"=1'-0" SCALE: 3"=1'-0" SCALE: 3"=1'-0" I D-03E,F,IVED A I B I C I D I E I F I G I H I J ®2020 MATTER PLANNIN5/S15 t iN BUILDING DEPARTMENT