Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.716 E Hopkins Ave.0098-2022-BCHO (3)
Isokern® BVETTO' B-Vent Gas Fireplaces and Chimney System Installation, Operation, Maintenance and Owner's Manual Isokern BVETTO Models 80B36 & 80B46 A PRODUCT OF EARTHCORE° INDUSTRIES, LLC IMPORTANT: This manual contains assembly rules, installation steps and guidelines, and use and maintenance in- structions for Isokern B-VENT gas appliances (BVETTO).This manual must become the property of and be reviewed by all current and future users of this product. It is the responsibility of the distributor, general contractor and the installer of this product that the instructions in this manual are followed exactly and,further that the allowed gas log appliance used in this product be installed in strict accordance with the gas log manufacturer's listing and explicit installation and operation instructions. INSTALLER: Leave this manual with the appliance CONSUMER: Retain this manual for future reference Be Sure to Read Entire Manual Before Beginning Construction. Contents of this manual may change without prior notification. Do not install the BVETTO B-Vent Gas Fireplace in a AWARNING: manufactured home or mobile home or recreational FIRE OR EXPLOSION HAZARD vehicle. Failure to follow safety warning exactly could result in serious injury, death, or property damage. — This appliance complies with National Safety and is tested and listed to ANSI Z21.50 - 2014 as — Do not store or use gasoline or other vented gas fireplaces. flammable vapors and liquids in the vicinity — Installation must conform to local codes. Check of this or any other appliance. local codes prior to installation. In the absence of local codes, installation must conform with —WHATTO DO IF YOU SMELL GAS current National Fuel Gas Code,ANSI Z223.1. • Do not try to light any appliance. • Leave the building immediately. INSTALLATION INSTRUCTION; • Do not touch any electrical switch; do not REQUIRED ON SITE use any phone in your building. AT TIME OF INSPECTION • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's PFS Report No. 09 79 instructions. SAP No. 506022-03 USA: ANSI Z21.50 2019 • If you cannot reach your gas supplier, call the fire department. Canadian: CSA 2.22 2019 — Installation and service must be performed ppi® Issued: December 2021 by a qualified installer, service agency or the Revision: 007 gas supplier. US ©2017 Earthcore Industries, LLC THESE FIREPLACES ARE DESIGNED for USE with: PROPANE (LP) or NATURAL GAS (NG), ONLY 12/23/2022 THIS MANUAL CAN ONLY BE REPRODUCED IN ITS ENTIRETY ASPEN BUILDING DEPARTMENT Earthcore Industries The latest revision of this installation manual is available on the Earthcore website: https://earthcore.co/installation-manuals/ . 1 ra: rtnellAm . . . . . I.r 7 • p SCAN RECEIVED 12/23/2022 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Table of Contents General Information 3 B-Vent Metal Chimney Installation 21 - 22 Safety Instructions 4 - 5 Firebrick Installation 23 BVETTO B-Vent Series 36" Drawing 6 Flush Wall Finish Detail 24 Component List - BVETTO B-Vent Series 36"..7 Clearance to Combustible Trim 25 BVETTO B-Vent Series 46" Drawing 8 ISOKERN Gas Log Set - Component List - BVETTO B-Vent Series 46"..9 General Information 26 Burner Parts List 27 Required Clearance to Combustibles 10 Wiring Diagrams 28 Burner Installation 29-31 Calculating Flooring Loads 11 Remote Lighting/Shutdown 31 Remote Control Operation 32 Rough Framing Dimensions 12 LogPlacement 33 Troubleshooting 34 General Assembly Instructions 13 Assembly Instructions ECODAMPER System BVETTO B-Vent Series 14 - 18 GeneralInformation 35 Installation 36 B-Vent Metal Chimney Installation - General Information 19 Registration Card 39 B-Vent Metal Chimney Components 20 Warranty 41 BVETTO Rating Label ISOKERN BVETTO B-VENT GAS FIREPLACE:MODELS 80B36 AND 80B46 P� I MODEL w LISTED VENTED GAS FIREPLACE PER USA:ANSI Z21.50-2019 IBV MODEL# AND CANADIAN:CSA 2.22.2019 C US 080836 0801346 PFS REPORT NO.F0979 NOT FOR USE WITH SOLID FUEL SERIAL NO: B000001 SUITABLE FOR USE WITH PROPANE(LP)OR NATURAL GAS,SEE GAS IDENTIFYING TAG ON BURNER I]IBV36 MODEL#80636 PROPANE(LP)BTU MIN:22,000;BTU MAX:50,000 0 IBV36 MODEL#80B36 NATURAL GAS(NG)BTU MIN:21,000;BTU MAX:65,000 0 IBV46 MODEL#80B46 PROPANE(LP)BTU MIN:23,000;BTU MAX:60,000 1]IBV46 MODEL#801346 NATURAL GAS(NG)BTU MIN:22,000;BTU MAX:75,000 .See Burner Rating Plate For Additional Information See Installation and Operating Instructions For This Model and ICC#ESR-4873 MANIFOLD PRESSURE:PROPANE(LP):10"WATER COLUMN;NATURAL GAS:3.5"WATER COLUMN MINIMUM PERMISSIBLE GAS SUPPLY PRESSURE FR PURPOSE OF INPUT ADJUSTMENT:PROPANE (LP):11"WATER COLUMN I NATURAL GAS:5"WATER COLUMN ELECTRICAL RATING: CLEARANCE TO COMBUSTIBLES: UNIT:ELECTRONIC SMOKE DOME FRONT AND UNIT SIDES =Oin 1 PH UNIT REAR =1.5in. 60mm 60 HZ COMBUSTIBLE SHEATHING ABOVE OPENING = 205mm 120 VOLTS TOP SHEATHING OR TRIM TO OPENING SIDES =Rin. 205mm MANTEL ABOVE OPENING =12in. 305mm LESS THAN 5 AMPS INSULATION FROM FIREBOX =3in. 75mm "CAUTION:PPIAC THIS APPLIANCE IS ONLY FOR USE WITH THEGTYPE OF GAS INDICATED ON THE BURNER RATING PLATE.THIS RECEIVED APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES" This appliance must be installed in accordance with local codes,if any,if none,follow the current ANSI 2223.0/NFPA 54 or CSA B149.1 MADE IN USA EARTHCORE INDUSTRIES HEADQUARTERS CHESAPEAKE,VA 23323 JACKSONVILLE,FL 322% 12/23/2 0 2 2 2 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace General Information BVETTO Models 80B36 and 80B46 are tested and fireplace operation. Check local codes for combustion air listed by PFS Corp., USA Report No. 09-79 to ANSI requirements. Z21.50 - 2014 and Canadian Standard CSA 2.22 - 2014. Each of these topics will be covered in detail The BVETTO models are top-vented, gas only fireplaces throughout this manual. Special attention must be given that are listed for use only with the ISOKERN Gas Log to each topic as the installation progresses. appliance listed in this installation manual. These gas The installation of the BVETTO must conform with appliances come with a gas control valve that includes local codes or, in the absence of local codes, with the an automatic shut-off switch.The gas valve is available in current National Fuel Gas Code, ANSI-Z223.1/NFPA 54 a millivolt remote control pilot assembly. or the current Natural Gas and Propane Installation Code, The exhaust flue gases are to be vented through CSA B149.1. the top of the unit with listed B-Vent piping. A ten inch (10") diameter, double wall B-Venting system and a listed Seismic Code Specifications vent cap are not supplied but are required for proper If installation of the Isokern Firebox is to be installed in operation of all BVETTO Models, 36 and 46. See venting an area with Seismic Codes please follow these instruc- instructions on pages 19-22. tions. Four No.4 ASTM A615 Grade 40 minimum,vertical reinforcing bars, 2 on each side of the fine box running WARNING: This gas appliance must not be connected from mid-height (where the tapered section of the box to a chimney flue servicing a solid fuel burning appliance. begins) of the structure to approximately 4 inches into the concrete slab (for anchorage). Intended Use Statement The BVETTO is intended to burn propane (LP) gas or natural gas (NG), only.This appliance is not intended to be used as a primary source of heat. The BVETTO and its approved components are safe when installed according to this installation manual and when operated as recommended by the manufacturer. Unless you use Earthcore Industries, LLC approved components tested for this appliance, you may cause a fire hazard or serious injury. Before you begin the installation of this appliance, read these instructions completely. Earthcore Industries, LLC disclaims any responsibility for the following actions: 1. Modification of the appliance or any of its components. 2. Use of any component part not approved by Earthcore Industries in combination with this appliance. 3. Installation or operation in a manner other than in- structed in this manual. 4. Burning of anything (solid fuel) other than the listed Important: The top plate of the firebox is not meant to gas log unit and the type of gas approved for use in this be used as a structural support. Please consult structural gas appliance. engineer for structural support of any veneer bearing weight on the Isokern top plate. The most important areas of concern with the installation of the top venting BVETTO are clearance to Note: Do not scale drawings. Illustrations in this manual combustible materials, proper assembly of component are not to scale and are intended to show "typical" parts, load carrying capacity of underlying floor system, installations. height of chimney system, hearth extensions and the Nominal dimensions are given for design and framing techniques employed in applying finishing materials to reference only, since actual installation to job specific design preferences. Alwa the wall surrounding the BVETTO. Combustion air inlet stated minimum clearances to combus i e materia s. kits though not required for the BVETTO may help improve Do not violate any specific installation requije2y�tsj,2022 3 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Safety Instructions WARNING: This product contains or generates 4. For propane (LP) use do not place propane supply chemicals known to the state of California to cause tank(s) inside any structure. Locate propane supply cancer or birth defects or other reproductive harm. tank(s) outdoors. To prevent performance problems, do not use propane fuel tank of less than 100 lbs. capacity. IMPORTANT: Read this owner's manual carefully and completely before trying to assemble, operate or 5. Do not install the BVETTO B-Vent Gas Fireplace in a service this fireplace. Improper use of this fireplace manufactured home or mobile home or recreational can cause serious injury or death from fire, burns, vehicle. explosions and carbon monoxide poisoning. 6.This fireplace reaches high temperature. Keep children DANGER: CARBON MONOXIDE POISONING MAY and adults away from hot surfaces to avoid burns or LEAD TO DEATH! clothing ignition. Fireplace will remain hot for a time after This fireplace is a vented product and will not produce shutdown. Allow surfaces to cool before touching. any gas leakage into your home if properly installed by a qualified service person. If this unit is not properly 7.Turn the BVETTO B-Vent Fireplace off and allow to cool installed by a qualified service person, gas leakage may before servicing. Always shut off any electricity and gas occur. to the BVETTO B-Vent Fireplace while working on it. Only Propane (LP) gas and natural gas (NG) are both a qualified service person should install, service or repair colorless and odorless gases. An odor-making agent is this fireplace. Have your fireplace inspected annually by a added to each of these gases to help you detect a gas qualified service person. leak. However, the odor added to these gases can fade and gas may be present even though no odor exists. 8. It is imperative that the unit's control areas, burners Carbon Monoxide Poisoning: Early signs of carbon and circulation air passages be kept clean. monoxide poisoning resemble flu symptoms, including headaches, dizziness or nausea. If you have these signs 9. Venting system should be inspected annually by a the fireplace may not have been installed properly, get qualified service person. If needed have venting system fresh air at once! Have the fireplace inspected and cleaned or repaired. serviced bya qualified service person or your gas supplier. Some people are more affected by carbon monoxide 10. Keep all combustible material, gasoline and other than others.These include pregnant women, people with flammable liquids at a safe distance from the fireplace. heart or lung diseases or anemia, people at high altitude Do not use the fireplace where these items are used or or under the influence of alcohol. Earthcore Industries stored. Decorations, clothing and other such combustible strongly recommends the use of a carbon monoxide items should not be placed on the fireplace. detector/alarm device wherever gas fired appliances are in use. 11. Do not use the BVETTO B-Vent Series Fireplace to All parties either involved in or associated with the cook food or burn paper or other objects. installation, service and use of this fireplace must read this entire manual. Keep this manual for reference and as 12. Do not use any solid fuels - wood, coal, paper, a guide book to safe operation of this fireplace. cardboard, etc. - in this fireplace. Use only the gas type listed on the fireplace's gas log label. WARNING: This unit is not for use with solid fuel. 14. Keep all insulation and vapor barriers a minimum 1.Always check local building codes governing fireplaces of three inches (3") away from all BVETTO B-Vent and fireplace installations. The BVETTO B-Vent Series and chimney components. installation must comply with all local, regional, state and national codes and regulations. 15. This American Gas Association fact sheet provides an overview of the requirements for the electrical 2.The BVETTO B-Vent Series fireplaces are listed for use bonding of fuel gas piping systems to the electrical with the decorative gas log appliance listed in this grounding system based on ANSI Z223.1/NFPA 54, manual only. National Fuel Gas Code - 2021 (NFGC). The bonding requirements in previous code editions, in local 3. This appliance is only for use with the type of gas jurisdictions or in specific situations, may differ. indicated on the rating plate.This appliance can be field � �y J�(� �A converted for use with other gases with Propane (LP) or 16. Do not pack or fill required air space ,.�► �/ Natural Gas (NG). insulation or other material. No material is allowed in these spaces. 12/23/2022 4 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Safety Instructions 17. Never install a BVETTO B-Vent Series component, 29. Do not nail or screw into the isokern fireplace, chimney component or accessory that has visible or which includes firebox or smoke dome components suspected physical damage as a result of handling or unless attaching the anchor plate for the metal transportation. These items should be inspected by a flue system. This may alter the integrity of the qualified representative to ensure safe condition. When fireplace and cause a house fire.THIS WILL VOID THE in doubt, consult your local supplier. WARRANTY OF THE FIREPLACE. 18. Do not alter or modify the BVETTO B-Vent Series, 30. Never spray or apply any type of sealer, insulation or venting components under any circumstances. other materials to the fireplace. Modification or alteration of the venting components may void manufacturer's warranty, listings and approvals. 19. Do not use a fireplace blower insert, heat exchanger or any other product not specified by the manufacturer herein for use with this fireplace. 20.Do not use any BVETTO B-Vent Series appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 21.The BVETTO B-Vent Series is not intended to heat an entire home or to be used as a heat source. '',��II�II^'' II��IIIII` , 22. Children and adults should be alerted to the hazards Io.4 of high surface temperature and should stay away from this appliance to avoid burns or clothing ignition. 23. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental \/ contact burns.A physical barrier is recommended if there are at-risk individuals in the house.To restrict access to the fireplace, install a adjustable safety gate to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces. i 24. Clothing or flammable material should not be placed , ` / on or near the appliance. 25. Due to high temperatures, the appliance should POP' ,be located out of traffic and away from furniture and draperies. - 28. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to �I excessive lint from carpeting, bedding material, etcetera. 11 It is imperative that control compartments, burners, and ^� circulating air passageways of the appliance be kept clean. ��i * p ,,. , ED �1 /2 ; 2022 5 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 BVETTO B-Vent Series 36" (80B36) 41 22 t/z" ►- 25 1/4 IIIIIIIIIIIIIIIIIIIIIIIIIIIIII ii winninninnininin / = I IN • IUo�" 16" i 11, High Temp 11 Lintel Down Draft 6 Diverter • i 711/4" 71 'A" iim 1 A En' A mil High Temperatur_ Limit Switch 36'/s" II 31 1/2" 34 /2" 4_ li 31 t/z" 10�1/2 " II II V v � 1 43 Note:These are inside rough 5 dimensions Front View before firebrick Side View Uses 10"Metal-Fab or DuraVentType B Gas Vent Chimney. P H I 103/4" 27 '/4" ID- 25 1/a" 25 '/4', 14" Flue Outlet -0--221/2"- = 361/8" ►- 43" ► Plan View Top View RECEIVED 12/23/2022 6 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Component List - BVETTO B-Vent Series 36" (80B36) Component Part# Description Component Part# Description r25Va" „5 10%' 21 Isokern BVETTO `'y. 36S Isokern BVETTO Base Plate Top Plate /43" 22%� " ` V 12 Isokern BVETTO 11 Isokern BVETTO Smoke Dome(QTY.2) 15" Smoke Dome(QTY.2) 15" 429/aN/ 1 32'/zN./ 1 25%"�03" /, 701/2" \✓ 15" 34 Isokern BVETTO Isokern BVETTO 25 Backwall(QTY.3)* Side Sloping(QTY.4) 30" , / $" *NOTE: One additional backwall and two additional sidewalls 25% A can be added to obtain an opening of 42"tall before brick �II 20 Isokern BVETTO is installed, as well as,Two additional backwalls and four 10/ I Sidewall(QTY.6)* additional sidewalls can be added to obtain an opening of 521/2" r/; tall before brick is installed.To obtain this height the additional pieces will need to be ordered in addition to the 80B36 fireplace kit. RECEIVED 12/23/2022 7 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 BVETTO B-Vent Series 46" (80B46) 331/2 25 IA" II IIIIIIIIIIIIIIIIIIIIIIIIIIII Hiiinininiiiiiiiiiiiiiiiii 111 IU $ " 363/4" lii HighLintelli Down Temp Draft 1 6" Diverter l i711/4" 71 '/4" 1 N•a "MEE4\ High Temperature II II31 1/2" Limit Switch 47 1/8" 34 1/2" 31 '/z" IIV � V • 53" w Note:These are inside rough 5 dimensions Front View before firebrick Side View Uses 10"Metal-Fab or DuraVent Type B Gas Vent Chimney. I :10 3/4" 371/4"_,„,, • 25 '/ "\ 4" 25 /4 14" Flue Outlet 1 331/2"-IP' -4 47 1/8" ► -4 53" ► Plan View Top View RECEIVED 12/23/2022 8 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Component List - BVETTO B-Vent Series 46" (80B46) Component Part# Description Component Part# Description r25V4" „5 10%' 23 Isokern BVETTO `' 77 Isokern BVETTO Base Plate Top Plate /53" 33'/z �3/s" V 13 Isokern BVETTO 11 Isokern BVETTO Smoke Dome(QTY.2) 15" Smoke Dome(QTY.2) 15" 429/4N/ 1 529/4N./ 1 0 25'/4"� ,3" , 70' " 15" 34 Isokern BVETTO_ l \ 31 Isokern BVETTO Side Sloping(QTY.4) // Backwall(Q(QTY.3)* 40" , / -Z\ 8" *NOTE: One additional backwall and two additional sidewalls 25' , A can be added to obtain an opening of 42"tall before brick II20 Isokern BVETTO is installed, as well as,Two additional backwalls and four 101/2 I Sidewall(QTY.6)* additional sidewalls can be added to obtain an opening of 521/2" 2%'S tall before brick is installed.To obtain this height the additional pieces will need to be ordered in addition to the 80B46 fireplace kit. RECEIVED 12/23/2022 9 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Required Clearance to Combustibles The BVETTO fireplaces and chimney systems are tested and listed for installation with "clearance to combustibles" as follows: 4010 Zero inch (0") clearance to the combustible floor; (Isokern Base Plate must be used) ;` Zero inch (0") clearance at the Isokern firebox sides and front and smoke dome sides and front. '` One and one half inches (1-1/2") clearance at the ., Isokern firebox back wall and smoke dome back wall. ��, One inch (1 ") minimum air space to combustibles at "11111iiiiiliiii I� ` all B-Vent double wall chimney components' outer layer. , *AllilliP.,,,,11111111111 When installing on a combustible floor system the front of the fireplace must be covered with a non- combustible hearth extension material set tight against '► the fireplace front and extending at least twenty inches �' (20") out from the finished front of the fireplace and at least twelve inches(12") beyond the finished sides of the fireplace opening. IMPORTANT: "Combustibles" are defined as "normal Ltle construction materials" and considered to be: wood I framing materials, particle board, mill board, plywood paneling, plywood subflooring and wood flooring. CAUTION: Maintain three inches (3") clearance to insulation and vapor barriers from all firebox, smoke III � dome and B-Vent flue components' outer layer. jlr\U �I� EXCEPTION: If insulation is used in walls surrounding � �Iljj���� / the fireplace, insulation may be installed behind sheathing ,- ' ' of gypsum board, plywood, particle board or other rigid, y�/ fire rated material on the side facing the Isokern. The facing material cannot be within 1 1/2" to the fireplace sidewalls. NOTES: 1. The fireplaces must sit upon a support designed to bear the total installed weight of the fireplace. 2. All BVETTO installations will result in the minimum finished fire brick floor of the firebox being at least four jand one half inches (4-1/2") above the combustible floor III II system. Never place a BVETTO on a combustible floor II// without the e base plate. 1IA„ / Min. ►_�1.1_II �LIIIII►III COMBUSTIBLE FRAMING/ �j *II B . II B,. Mi„n. 11 11_Min. `, ''; IIII 111 \i G VED FIGURE 1 FIGURE 2 12/23/2022 10 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Calculating Flooring Loads Floor framing for BVETTO installation will need to be designed and built to accept substantial dead loads spread over a relative small floor area. (Figure 3) The following weights and sizes can be used to calculate loading. It is the contractor's responsibility to provide adequate floor system load capacity. BVETTO Weights and Load Calculations Total dead load amounts include (but are not necessarily limited to) the following items and their corresponding weight estimates as listed below: 1. Isokern unit model weights: a. BVETTO-46: 1400 lb - b. BVETTO-36: 1200 lb 2. Approximate weight of log set: 100 lb. 3. Fire brick and Adhesive: 350 lbs. - 1800 lbs. depending on brick size and pattern 4. Facing material: per general contractor Hearth Extension 5. B-Vent metal flue: per manufacturer (non combustible) The floor area for each model is as follows: BVETTO-46 @ 53" x 25.25" = 9.30 sq. ft. BVETTO-36 @ 43" x 25.25" = 7.54 sq. ft. [// ///// / Earthcore is not responsible for structural floor support details for this fireplace system. Unless otherwise noted all floor framing drawings in this manual are merely illustrations to indicate the presence of an Combustible underlying floor system. Floor System Consult your local structural engineer for proper floor (non-insulated) system design, sizing and specifications. FIGURE 3 RECEIVED 12/23/2022 11 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Rough Framing Dimensions Typical Installation Framing Dimensions BVETTO Width Height Depth ® A B C Model 36 44" 72,'83", 93" 26 3A" Model 46 54" 72,'83", 93" 26 3A" Framed '/// ® Notes: Opening / 1. "B" includes the 3" thick base plate. 2. "Raised hearth" requires additional rough opening height at "B" equal to the height of the raised hearth detail. 3. Rough framing dimension for width "A" allows for the 1/2" for each side to build fireplace in the space.There is \� 0" required clearance at the sides of the Fireplace. A 4. Rough framing dimension for depth "C" allows for the Framed required 1-1/2" clearance at the back of the Fireplace. Opening FIGURE 4 5. Opening height of 83" requires minimum 9' flue; 93" height requires minimum 12' flue. Dui i ii ii ini ini �i M— 1�. .,;.. Corner Installation Framing Dimensions c ' e BVETTO A B C D ' 2\ Model 36 44" 49" 32" 70" c Model 46 54" 59" 39" 77" A Note:The following chart of plan dimensions is intended I -," to aid in the positioning of an BVETTO in a corner I condition. I FIGURE 5 RECEIVED 12/23/2022 12 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace General Assembly Instructions When beginning the assembly process, mix the Earthcore Adhesive with clean water to a smooth, workable texture (without lumps or dry pockets) of a "toothpaste" consistency. This mixture is suitable for application onto Isokern components by using a masonry grout bag supplied with the unit. Attention should be paid that the Adhesive mixture is not too thin or runny, as this will not allow the Adhesive to reach its maximum bonding strength. Mark out the position of the base plate on the supporting floor system. Apply a thin layer of Earthcore Earthcore Adhesive to the area and set base plate in the Adhesive. Adhesive (Figure 6) Earthcore Adhesive is then squeezed from a grout bag onto the contact surfaces of the Isokern components as FIGURE 6 they are fitted together. NOTE: It is important that a 1/2" bead of Adhesive is piped onto all the components' contact surfaces, about 1/2" in from all edges. (Figure 7) Earthcore Adhesive Earthcore When setting the next component onto the Adhered contact surface of the base plate, some Adhesive should Adhesive squeeze out along the face of the entire joint as a sign of complete and proper sealing of the joint. On broader contact surfaces it is advisable to apply several additional 1/2" beads of the Earthcore Adhesive to the area to assure proper sealing of the joint. Properly Adhered firebox and smoke dome assembly requires approximately 100 pounds (dry measure) of Earthcore Adhesive. Leveling and Aligning Components: FIGURE 7 Be sure to assemble all Isokern components level and flush with adjoining components. Earthcore Adhesive is not intended to create a Adhesive joint of any thickness for leveling purposes. Therefore, leveling and alignment adjustments are made by the use of small plastic shims supplied with the unit. (Figure 8) 411000 The shims can be inserted under a component to level and align it with adjacent Isokern components. Be sure to re-grout any and all gaps resulting from shim insertion to maintain components to full bearing. Broken Components: Components can be repaired by using Earthcore Adhesive along the break line as the component is set into place. Components broken into multiple small pieces should be discarded and replaced. IMPORTANT: 1.Do not mix Earthcore Adhesive with anti-freeze agents. 2.The maximum recommended Adhesive joint thickness FIGURE 8 at Isokern components is 1/4'.' 12/23/2022 13 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Assembly Instructions - BVETTO B-Vent Series The following assembly instructions identify the parts by name, part number and the placement of each part in the assembly process. NOTE:At all component placement, be sure to Adhesive Base Plate: all contact surfaces with Earthcore Adhesive. Check for 36": Part 21 complete sealing of each contact joint while assembly • 46": Part 23 progresses. 1. Set the base plates in a full bed of Earthcore Adhesive on a level support surface. See page 11 for supporting floor system. (Figure 9). Do not set the base plate so I Earthcore that it is in span. Adhesive • Flush Hearth: If the design preference is for a "flush hearth" the base FIGURE 9 plate can be omitted from the assembly and the firebox walls built directly on a minimum 4" concrete support slab.The fire brick floor of the firebox is then set directly II to the concrete support slab. This makes the fireplace finished fire brick floor approximately one and one-half inches (1-1/2") above the top of the concrete support slab. The noncombustible hearth material will butt tight up against the fire brick floor. (Figure 10) Illi.j1P1 Raised Hearth: If the design preference is for a raised hearth (floor ' -�• of the fireplace elevated above the room's floor), then the base plate can be set on a noncombustible platform FIGURE 10 `1 that is built up to the desired raised hearth height on the \ concrete support slab. (Figure 11) I When calculatingraised hearth height be sure to gFlush Hearth 4111 allow for the three inch (3") thick base plate plus the one on Concrete and one half inch (1-1/2") thick fire brick floor in addition Foundations Only to the height of the platform. For all "raised hearth" construction where concrete l blocks are used to create the raised platform, it is - necessary to use the base plate. Be sure to Adhesive ,\/ the concrete block platform together. CMU used for base plate support should be rated ASTM 90. ' Whether a flush hearth or al raised hearth is installed, I, the combustible floor in front of the fireplace must be I- `' II- covered with a noncombustible hearth extension set I/\� / I 1 tight against the fireplace front and extending at least 4,\ II i I 20 inches out from the finished fireplace and at least 12 II I inches beyond the finished sides of the fireplace opening. ` 1 ! 1 WARNING: "Flush hearth" installations are possible `\i / i ♦ only where the BVETTO support is a concrete slab FIGURE 11 without any wood underpinning as the base plate \� I i is omitted. Never place a BVETTO on a combustible 'l/I floor without the base plate. Raised hearth for wood or RE�s-� � IV D concrete installs 12/23/2022 14 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Assembly Instructions - BVETTO B-Vent Series 2. Set the first course of the firebox side walls and back - Earthcore walls into place. (Figure 12-13) \ Adhesive NOTE: It may be convenient to dry set the first course of I� side walls and back walls into place on the Isokern base Part#20 plate and then trace their position on the base plate with a pencil. • After outlining the dry set pieces, remove them and \ apply Earthcore Adhesive to the areas traced on the base plate where the side walls and back wall are to sit. By doing this, the first layer of wall components can be set directly into Adhesive already applied to the proper areas on the base plate. 3. It is required that the two supplied high temperature wires be routed from the inside of the BVETTO as follows: Once the lowest, left hand side wall firebox FIGURE 12 component is set in place (left,when facing the fireplace) drill a 1/4" - 3/8" dia. hole in the inner face of this side wall located four to six inches (4" -6") out from the back Earthcore wall of the BVETTO and at three to four inches (3" -4") Adhesive above the BVETTO base plate. (Figure 14) Backwall: This drill hole must intersect the hollow core of the , 36": Part 25 BVETTO firebox side wall. 46": Part 31 Feed the two lengths of high temperature wire from the inside of the BVETTO firebox through the drilled hole Part#20 \ and into hollow space of the firebox side wall. Bring the two lengths of wire up and out through the top of the side wall component (Figure 14). NOTE: For Seismic Installation - With the Seismic installation the opening in the sidewalls are used to anchor the Isokern Fireplace to the floor with rebarb and Part#20 backfilled with concrete. The high tempertaure wires will need to be run outside of the Isokern unit and not through the openings in the sidewall. The wires will be run through the bottom course of the sidewall and out to the side of the Isokern Fireplace. FIGURE 13 Another 1/4" hole should be drilled in the first course of side sloping to attach to the high temperature wires to the high temp lintel for the High Temperature switch. 3. Continue assembly of the consecutive courses of the firebox side wall and back wall.Apply Adhesive to the top '1 \ \ of each layer of wall components, set the next course above into place. Be sure to Adhesive all vertical joints of the side wall to back wall connection when setting each component to its mate. (Figure 15) �. Look for some Adhesive to squeeze out along the joints of all contact surfaces as a sign that the joint is thoroughly sealed with the approved Adhesive. �EIVED lwougi4,9 22 15 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Assembly Instructions - BVETTO B-Vent Series Backwall: 4. When all of the firebox sidewall and backwall 36": Part 25 components are set, check the top surface of the firebox 46": Part 31 for level. If necessary, adjust the top surface of the box assembly for level by inserting a shim supplied with the unit between the lowest wall component and the top 11 surface of the base plate. Lairitildall Any gap created under the wall components during the Shim leveling process must be filled with Earthcore Adhesive to fill bearing against the base plate. 111110110 5. Begin the smoke dome assembly by setting the rear it p bottom smoke dome component on top of the firebox back wall assembly in a bed of Earthcore Adhesive.The smoke dome component should sit flush with the back FIGURE 15 side of the firebox assembly. (Figure 16) I Then set the front bottom smoke dome component across the firebox opening so that the smoke dome piece spans the firebox opening and is flush with the front of Smoke Dome: the firebox. 36": Part#11 4 6. Position the smoke dome's sloping sidewalls at each 46": Part#13 end of the bottom smoke dome components. The sloping sidewalls fit in between the front and rear smoke dome components and also fit into the 4l Is haunches at the ends of the front and rear smoke dome components. 100" The smoke dome sloping sidewalls have a beveled bott om, i om edge so that they will sit tight onto the flat top of 1.),,O the firebox side walls. I7. Set the upper course of front and rear smoke dome components directly on top of and aligned with the I bottom front and bottom rear smoke dome components that are already in place. FIGURE 16 I Set the two upper smoke dome sloping sidewalls into position, one at each end of the upper front and rear smoke dome components. (Figure 17) Top Plate: 8. Set the top plate into position and adhere on top of the 36": Part#36 smoke dome wall assembly. 46": Part#77 One side of the top plate shows a thickened center. This side is the bottom face. Side Sloping: The flue hole in the top plate is centered in the 36": Part#34 smoke dome from side to side but is offset from front to 41%4 ,I 46": Part#34 back, the center being ten and three-fourths inches (10 3/4") from the back of the firebox. (Figure17) 9pp/ 9.The high templintel, as supplied, is fortyfive inches(45") long and fits the BVETTO models 36&46. Field cut the high O- m lin I II h rf r lin r it f r h �` \/ to p to equa y at t e pe o ated es as equ ed o t e 111111141e 36" unit.This will ensure the limit switch and micro-switch are located in the proper position on the lintel. Connect the two (2) leads from the h Er) wires to the thermocouple junction bloc_ page 29). FIGURE 17 12/23/2022 16 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Assembly Instructions - BVETTO B-Vent Series ature Measure and locate the centerline of the fireplace opening. 2HignremperWfes Align notch at the front of the lintel to the centerline of the fireplace. Install lintel using 1 1/2" masonry screws. High Temperature Limit Switch NOTE: The limit switch and micro-switch are already supplied and mounted in the BVETTO high temp lintel compo-nent. Connect the two high temperature wires (coming out the top of the BVETTO left hand firebox side wall) to the two high temperature wires that are attached Tab stand verticent al ward to stand vertical to the limit switch. (both sides) FIGURE 18 The small tab near damper lever should be bent upward to stand vertical. This protects wires passing through the / op- LiTerminals'it ch harness. Front Alternate wire Facing WARNING: Do not bypass the high temperature location limit switch. I� ice= rir Install downdraft diverter at the top plate. (Figure 20) Orient assembly such that the wire cable is toward the front of the fireplace opening. Loosen screws on the cable clamp and loop between the two washers at the end of the handle assembly. NOTE: Wire clamp should be approximately 4" from f ` the washers.Tighten lock nuts on the handle if necessary. Pull cable to close the damper and adjust the length of wire cable by swinging the handle between open and close po-sitions. When in the open position, the damper 1101111111111H111° should be rotated a full 90 degrees from the closed /\' position. Re-tighten screws on the cable clamp and I remove excess cable. 1 The high templintel fits horizontallyuptoward the bottom \ 9 of the smoke dome. The adjoining short leg of the high B-vent metal lintel FIGURE 19 temp lintel fits up against the bottom of the smoke dome component. (Figure 19) The high temp lintel has 4 pilot holes for the screw placement. Attach the high temp lintel flush against the front face of the smoke dome with 4 mounting screws driv-en into the face of the BVETTO smoke dome. Smoke Dome Component Any excess wire draped between the high temp lintel and the left hand firebox sidewall should be neatly tucked into the hollow core of the left hand sidewall. Excess wire should not be visible below the canopy --a-, bottom. NOTE: The 2 high temperature wires inside of the BVETTO firebox will connect to the appropriate contacts found on the gas burner assembly during the installation HighTemperatureLimitSwitch of the gas log set. Metal Canopy RECEIVED 1?16Zaip?0022 17 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Access Modification - Combustion Air Kits, Gas & Electrical Line Feed A Four Inch (4") Combustion air inlet kits are The air kit is fitted into the front 1/3 of the side wall of the recommended by Earthcore and may help improve fireplace firebox by core drilling an appropriately sized hole at the operation in homes tightly sealed and with other ventilating selected firebox location. Keep the top of the access hole appliances installed (Figures 21 & 22). The following no more than six inches (6") above the finished firebrick is a general representation of a combustion air kit. floor.The hole size should allow f or a quarter inch ( 1/4") joint around the air access sleeve for heat expansion. Do not install in the rear of the firebox. Combustion air kits Flex Duct To Fireplace (All Parts Noncombustible) must be installed in accordance with local codes. Fireplace Make Up Air Requirements i Bvetto Series �� Exterior 14 Wall Model Opening Height (in) Consumption Air Flow (CFM) Skill*" 80B36 30 272 opm . II 80B36 40 365 FIGURE 21� 80B36 50 459 Exterior Air Vent 80B46 30 348 With Dress Plate 80B46 40 466 806 50 587 WARNING: Do not use combustible duct material.Avoid installing a combustion air inlet where the opening could I be blocked by snow, bushes or other obstacles. Air inlet ducts shall not terminate in attic, basement or garage \/ spaces. ' Gas Line Feed irtiLl ' ' For a fireplace having the provision for installation of a gas - pipe,the provision is intended only for connection to a ' I/ decorative gas appliance. Gas line for gas log sets used in /` , the Isokern firebox can be routed through the side wall, by =, , drilling an appropriately sized hole using a masonry drill `II i� bit. (Figure Typical Placement of III \ ( g 23) Gas or Electric Conduit (See Detail Below) 4411 `ill CAUTION: When using the decorative appliance,the CAUTION: fireplace damper must be set in the fully open position. All access holes must be / FIGURE 22 grouted with mortar-after Electrical Line Feed line or conduit feed to seal any gaps or cracks around line can be routed through the MAGNUM firebox side walls by feed conduits drilling an appropriately sized hole using a masonry drill bit (Figure 23). Be sure to follow the gas log Appliance Manufacturer's explicit electrical line connection instructions for vented masonry fireplace installations. Gas Fire Brick Side line and electric line must be fed through separate access Ir holes. Gas or Electric CAUTION:All access holes must be grouteittartarivED Conduit I PA NOTE: Fill AnyGaps after line or conduit feed -to seal any gap Around Conduit with Mortar around line feed conduits. (Figure 23) FIGURE 23 12/23/2022 18 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace B-Vent Metal Chimney Installation - General Information The BVETTO Series Fireplaces are tested and listed or try to match with other products or use improvised for use with the specified factory-built metal B-Vent solutions. Chimney Systems. The design and installation require Install your Isokern fireplace as described in this that the system use the Metal-Fab Type B Gas Vent or installation manual and maintain all required clearances. the DuraVentType B Gas Vent Chimney Systems. Connect only one fireplace per chimney. Follow the fireplace safety manual for maximum efficiency and APPROVED MANUFACTURERS safety. Do not over fire. Any damage to the fireplace or Metal-Fab®(UL 441 & ULC S605)Type B Gas Vent chimney can possibly void the warranty. DuraVent'9UL 441 & ULC S605)Type B Gas Vent Do not burn wood, driftwood, plastic, or chemically treated wood such as railroad ties.They are corrosive to NOTE: The selected, approved chimney manufacturer your chimney system.THIS ISA GAS ONLY FIREPLACE. must provide the masonry anchor plate with down draft diverter designed to fit their flue system. (Figure 24) All chimneys and chimney liners must be installed in accordance with the manufacturer's installation A major cause of chimney related fires is instructions and under the terms of their listing for use with open faced fireplaces. failure to maintain required clearance (air spaces) to combustible material*. Minimum Refer to metal flue manufacturer for number clearance for 10" diameter air-cooled of offsets, approved chimney shrouds, clearance to chimney is one (1) inches. It is of utmost combustibles and any information specific to that flue importance that this chimney is installed system. Only tested and listed chimney terminations only in accordance with these instructions. can be used on metal flue chimney systems. B-Vent Chimney is not designed for use on products that operate at continuous temperatures in excess of 1000°F. MECHANICAL VENT SYSTEMS IMPORTANT:Never fill any required clearance space with It is acceptable to use mechanical draft systems of venting insulation or any other building materials surrounding the companies that do engineering calculations and make chimney. necessary recommendations for fan size and flue vent Exterior metal parts, with exception of the top diameter following the guidelines of NFPA 211/2016. portion of the chimney cap, can be painted with a high Installation of such systems must also follow the temperature rust proof paint. Wash the metal surface mechanical draft company's explicit installation and with a vinegar and water solution to remove any residue operation instructions. before painting. Painting the chimney will help to increase chimney life. IMPORTANT: MECHANICAL VENT SYSTEMS Interior chimneys shall be enclosed where they If a mechanical draft system in incorporated with this extend through closets, storage areas, occupied spaces, fireplace, the draft system must be from an approved or anywhere the surface of the chimney could be manufacturer.Any mechanical draft system shall be contacted by persons or combustible materials. The air installed according to the manufacturer's instructions. space between the outer wall of the chimney and the Any installed mechanical draft system must be interlocked enclosure shall not be less than 1 inches. with the gas appliance control system to allow appliance Except for installation in one or two family dwellings, operation only when the mechanical draft system in in a factory built chimney that extends through any zone above that on which the connected appliance is located is operation. to be provided with an enclosure having a fire resistance rating equal to or greater than that of the floor or roof assemblies through which it passes. In cold climates, chimneys mounted on an outside wall should be enclosed in a chase. Exterior chases reduce condensation and enhance draft. Proper planning for your B-Vent Chimney installation will result in greater safety, efficiency and convenience. RECEIVED You must use only B-Vent Chimney parts and components to maintain a listed chimney system. Do not mix parts 12/23/2022 19 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Metal-Fab B-Vent Components DuraVent B-Vent Components Component Part# Description Component Part# Description 1OM12 B-Vent 12"Length 1OM18 B-Vent 18"Length 10GV18 B-Vent 18"Length 1OM24 B-Vent 24"Length 1OM3 B-Vent 3'Length 1OM4 B-Vent 4'Length — - 1OGV36 B-Vent 3'Length 1OM5 B-Vent 5'Length 1 1OM12A 10M 18A B-Vent 12"Adjustable Length B-Vent 18"Adjustable Length 1OG1V12A B-Vent 12"Adjustable Length 4\ (' . pp 1OM45 45 Deg Adjustable Elbow Akl'' 1OGVL45 45 Deg Adjustable Elbow Y i u m BVT-1 B-Vent Metal Lintel 611-3.411111 BVT-2 B-Vent Draft Diverter 41,1 1OMGR B-Vent Guy Ring 1OGVRS B-Vent Firestop Support 1OMF B-Vent Standard Flashing 4 10GVF B-Vent Adjustable Flashing ''IIIIIIILIIOPPP-' 1OMFS B-Vent Firestop C:1110GVFS B-Vent Firestop - 1.°1.17)' 10MSC B-Vent Storm Collar41:70•_. lOGVSC B-Vent Storm Collar li1OMFT B-Vent Flat Tall Cone Flashing I 1OGVFF B-Vent FlatTall Cone Flashing f C EIVED 10MC B-Vent Vent Cap/Termination 1OGVVT B-VentVeRap ermmation :u O 12/23/2022 20 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace B-Vent Metal Chimney Installation 1.Mount Anchor Plate with down draft diverter:Chimneys B-Vent Draft Diverter for Isokern BVETTO fireplaces begin with an Anchor Plate with down draft diverter. It is important that the surface of the Isokern chimney has a level surface on which to attach the Anchor Plate. If �Ipllllllllllllllp the top of the Isokern does not have a level surface, then it will need to be modified accordingly. ''lllllll�llll ''I Center the Inswool blanket over Isokern Top Plate ISOWOOL �� hole and trace outline of hole with a pen or marker. Cut Ceramic a hole in the blanket to match the hole in the Isokern Fiber Blanket top plate. Center the Inswool blanket over the Isokern Top Plate flue opening, then center anchor plate over the Inswool blanket. Make sure nothing interferes with the damper plate movement. Firebox Secure the Anchor Plate with four (4) masonry anchors. (Figure 24) If the Anchor Plate with Damper is installed the damper should swing freely. When the 14*� chain is pulled down, the damper should close (horizontal position). When the chain is released (no weight on the f /chain), the damper should swing open (vertical position). To install the lintel hook, place the damper plate in / the closed (horizontal) position. Determine and mark 1I, \ 'the position of the lintel hook. The lintel hook should be mounted in a position so as to provide a small amount oftension in the spring attached to the chain. \' The tension is needed to prevent the damper plate I from rattling when closed. Mount the lintel hook to masonry with the screws provided. Do not obstruct oval openings in the anchor plate. I / WARNING: Do not locate Anchor Plate with Down Draft FIGURE 24 Diverter in a location inaccessible for inspection, cleaning and servicing after installation. 2. Starting at the anchor plate, attach the first section of ..• I B-Vent Pipe. It is acceptable to use screws to attach the B-Vent to the anchor plate. suRELocKTM The B-Vent sections and components use the Metal- 1 I '1! TAB Fab positive twist lock for interconnections. Align the ;_ ends of the vent, push together then twist section to t lock in place. (Figure 25) No additional fasteners are required to assure a safe PI installation. It is acceptable to apply screws at the joints LINE UP PIPE ENDS TWIST TO ENGAGE TWIST if local code requires, or at the installingcontractor's AND PUSH TOGETHER. LOCKANDDEPRESS q SURELOCKT"TAB TO option, provided that the screws do not penetrate the SECURE PIPE SECTIONS p PATENT NO.6811190 flue. .11 NOTE: When installing B-Vent always align "Up" arrowQ t away from appliance. Chimneys must be installed so that access is provided for inspection and cleaning. 1 IC P.-1' ECEIVED TO UNLOCK,SIMPLY BEND PULL PIPE APART OUT THE TAB AND UNTWIST JL^ :RJAi L ^^L 22 21 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 B-Vent Metal Chimney Installation 3. If the B-Vent must penetrate the ceiling between floors, cut a hole in the ceiling 2 inches larger than the outside diameter (OD) of the outer casing. The B-Vent is to be centered in this opening.When installed, check to make sure the one inch (25.4 mm) clearance to combustible has been maintained. MC CAP NOTE: The B-Vent type chimney system must be [HIEN enclosed within a chase when installed in or passing STORM COLLAR through a living area where combustibles or people may 0 ROOFING TO come in contact with it. This is important to prevent OVERLAP possible personal injury or fire hazard. FLASHING BASE ON HIGH SIDE 4. Continue with B-Vent penetrating the roof. MF FLASHING NOTE: For Canadian installations, use labeled ULC section, designated with Suffix G, on vent sections exposed to atmosphere. MAINTAIN 1"(25.4 mm) WALL BAND-REQUIRED At the roof, the opening should be 2 inches (51 mm) CLEARANCE TO FOR EVERY 30FT. greater than the B-Vent OD. Above a flashingis COMBUSTIBLE THRU OF VENT HEIGHT the roof, JOIST AREA III required to maintain the one inch (25.4 mm) clearance to ■�! the combustibles of the roof. Installation of a storm collar allows water to drain over the flashing. 0 FIRESTOP 5. Install the B-Vent cap (MC) onto the B-Vent. ARROWS ALWAYS POINT AWAY FROM NOTE:Vent heightminimuminches,maximum is 100 height APPLIANCE FORg EACH SECTION 111 shall comply with NFPA 54,chapter 13.1 requirement A B-Vent Cap should be used on all installations FIGURE 26 to prevent back drafts and to keep out rain and debris. The vent must extend through a flashing, and should terminate with the lowest discharge opening no closer to the roof than the minimum height shown in the table below. These minimum heights may be used provided the vent is not less than 8' from any vertical wall. For installations not covered in table below, the lowest discharge opening of the vent cap should be at least 2' above the highest point where it passes through the roof. All gas vents extending above the roof more than 5 feet must be securely guyed or braced. Roof Pitch Minimum Height Flat to 7/12 (305 mm) 1.0 ft Over 7/12 to 8/12 (451 mm) 1.5 ft Over 8/12 to 9/12 (610 mm) 2.0 ft Over 9/12 to 10/12 (762 mm) 2.5 ft Over 10/12 to 11/12 (991 mm) 3.25 ft Over 11/12 to 12/12 (1218 mm) 4.0 ft Over 12/12 to 14/12 (1524 mm) 5.0 ft Over 14/12 to 16/12 (1829 mm) 6.0 ft Over 16/12 to 18/12 (2134 mm) 7.0 ft Over 18/12 to 20/12 (2286 mm) RECEIVED Over 20/12 to 21/12 (2438 mm) 12/23/2022 22 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Firebrick Installation The manufacturer requires that the fireplace fireboxes be covers the 1/2" expansion gaps where both the floor lined with a minimum one and one-eighth (1-1/8") thick firebrick and the back wall firebrick were held off the units firebrick for the Floor, Backwall and Sidewalls. Thicker side walls. (Figure 29) firebrick may be used as an option. The pattern for the All required through-wall accesses (gas and air intake firebrick lining is an owner option.The ISOSET mortar by supply access holes) should be drilled before the required Earthcore is to be used when lining the Isokern Fireplace. firebrick lining is installed. Do not cover these areas with firebrick. The ISOSET Firebrick Mortar Application: Earthcore makes no claims as to the performance •Add .75 quarts of water per 10Ibs of dry product until of firebrick or firebrick mortar(s). It is typical for heat completely blended. stress cracks to appear in the firebrick in fireplaces. • Only mix what can be utilized within 15 minutes • Do not retemper(the addition of water after the chemical reaction has begun). •The use of warm water will accelerate setup H H • Joint thickness should be thin (1/16"-1/8") I • Complete set time is between 48 &72 hours. • For best results, please allow seven days before heat is applied. •Approximately 35 to 40 lbs of prepared mortar will Expansion FIGURE 27 lay up one hundred 9x4'hx2' " Straights. 1/2"Gap • DO NOT add additives such as fireclay,sand, cement,or other accelerators. These instructions may vary because of different climates and conditions. The use of good masonry practices for your area should also be considered. Installation Instructions: 1.Wet mop the inside of the fireplace with a damp sponge to remove dust and loose particles from the interior before firebricking. I For Best Results: Expansion 1/2"Gap —\1 1. After wet sponged interior of firebox apply a 1/4 �! notch bed joint on rear sides and floor. Fire Brick Floor 2. Dip each firebrick in a pale of water before applying I(Built First) mortar to one side for adherence to firebox. I FIGURE 28 2. Face joint dimensions of 1/8" to 3/8" in the brick work is recommended and has the best appearance. Other face joint dimensions are acceptable however smaller joints may not leave room for heat expansion of firebrick. 3. Start the firebrick at the front edge of the floor of the Isokern firebox, proceeding inward toward the back. Let the floor brick gap approximately 1/2" off the back wall and side walls.This air space allows heat expansion of the firebrick and is to be left empty of mortar. (Figure 27) I I 4. Next,apply firebrick to the back wall of the unit.The back No Gaps' wall firebrick covers the 1/2" expansion gap left at the brick Fire Brick Floor floor along the back wall of the firebox. (Figure 28) and Back Wall (Built First) 5. Set the side wall firebrick by starting at the front edge ; RECEIVED of the unit's side wall and working inward toward the back wall firebrick. The side wall firebrick, when completed, ifI § n22 23 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Flush Wall Finish Detail BVETTO units are designed to be installed so that the Clearance to Drywall: rough front face of the Isokern firebox and smoke dome sit Drywall can be placed directly in contact with the front flush to the room face of the rough framing members that of the BVETTO smoke dome. (Figure 24)With the Isokern create the room wall finish. firebox/smoke dome set flush with the interior face of wall framing, drywall can be hung on the framing members and IMPORTANT: Do not build a combustible frame wall in pass across the face of the BVETTO smoke dome and in front of the BVETTO firebox/smoke dome assembly. contact with it. (Figure 30) The drywall must be cut back a minimum of eight inches (8") from the sides of the firebox opening and Wall Framing for the room wall where the BVETTO is eight inches (8") back from the top of the BVETTO firebox set must not be placed across the front face of the BVETTO opening, leaving BVETTO material exposed around the firebox and smoke dome assembly. face of the BVETTO firebox opening. These drywall cut back areas will be filled with grout in conjunction with the installation of the required fire brick lining requirements. Combustible wood sheathing such as plywood and particle board may be used to cover the front of the Isokern smoke dome and be in direct contact with it. Application of such combustible sheathings must assure that the sheathing is held a minimum of eight inches (8") away from each side of the finished fireplace opening and / a minimum of eight inches (8") inches above the top of the finished fireplace opening. (Figure 30&31) If combustible wood sheathing is installed across the face of the Isokern smoke dome front be sure that when r the required noncombustible finished facing materials are applied directly to the front of the BVETTO, that no ' gaps or voids are left behind the finished facing materials. ICompletely seal the required noncombustible finished Ifacing materials directly to the Isokern unit with Earthcore ���,��� Adhesive or other non-combustible grout. � �� IMPORTANT: Since there is no fire brick set along the FIGURE 30 `II top of the BVETTO firebox opening, when setting the ,♦101 noncombustible facing material onto the drywall across `11II the top of the firebox opening there will be a gap between 0 the back of the noncombustible finish material and the `\\ rough front face of the Isokern Smoke Dome. (Figure 32) Be sure to fill this gap with Earthcore Adhesive in conjunction with placement of the code required noncombustible finish facing material that is set across the top of the firebox opening. WARNING: Avoid false chimneys. 1011 IMPORTANT: Failure to seal an a s between the front 1 1 illrnil Y 9 p1 I\� � face of the BVETTO and the back of the noncombustible I►� FAIN finished facing material will create what is known as �`�z• I1 ��I p, a "false chimney" or "secondary chimney" A "false ',•4��,�� �i chimney"in this case is the narrow gap (mentioned above) �`�`` /r between the back of the noncombustible facing material ,.../ 4,,, � � � at the top of the firebox opening and the rough front of `� III `I the BVETTO smoke dome. If left unfilled this gap creates a "false chimney" which can cause a fire hazard by drawing ` considerable heat out of the firebox and `�`����` behind the noncombustible finish facing ar �E ���� into the wall cavity behind the drywall or other sheathing FIGURE 31 material that houses the Isokern fireplace. 12/23/2022 24 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Clearance to Combustible Trim Mantle and Mantle Shelf Clearances: All combustible trim projecting less than one and one-half inch (1 1/2") must be kept eight inches (8") from Ceiling the sides of the fireplace opening. All combustible trim projecting more than one and one-half inch (1 1/2") must °°°°°°°°ommi° kept twelve inches (12") from the fireplace opening. 42" be p p g minimum clearance (Figure 34) from opening Parts of the combustible mantle assembly located to ceiling along the sides of the fireplace opening, which project more than one and one half inches(1-1/2")from the face of the fireplace, shall have additional clearance equal to that of the projection. Parts of the combustible mantle assembly located above and projecting more than one and one half inches (1-1/2") from the fireplace opening shall not be placed -, less than twelve inches (12") from the top of the fireplace opening. (Figure 33) Adjoining Walls: Side walls and walls to rooms adjoining the Isokern fireplace installation cannot be closer than twenty four inches (24")to the finished fireplace opening. (Figure 33 Ceilings: The minimum clearance from the top of the fireplace Combustible FIGURE 32 Floor System opening to a ceiling is forty-two inches (42"). (Figure 32) (non-flammable) NOTE: "Clearance to Combustible Trim" are those distances required to ensure that a fireplace mantle or Adjoining Room Wall facing will not catch fire. In most cases the distances should also be adequate to prevent any discoloration or r' H warping due to heat. However each installation presents a unique and completely different set of circumstances involving many variables. These include paint or finish composition, previous L exposure to heat, methods and quality of construction, , 1 air flow patterns, etc. Because of these variables, the 4" 8" Hearth 112" manufacturer does not guarantee that heat warping or s Extension 20" discoloration will never occur. (non-combustible) 24" FIGURE 33 I I LI 0 Hearth Extension (non-combustible) Combustible / V ///A Floor System (non-flammable) } _a'g4022 25 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 ISOKERN Gas Log Set - General Information The BVETTO burner system is to be installed only in DO NOT USE IF GAS PRESSURE IS LOWERTHANTHE an ISOKERN B-vent (BVETTO) fireplace with a MINIMUM REQUIREMENT. working flue and constructed of noncombustible The minimum inlet gas-supply pressure for purposes material. The installation, including provisions for of input adjustment is 5" water column (w.c.) on natural combustion and ventilation air must conform with all gas and 11" w.c. on L.P. gas. Insuffi cient gas pressure guidelines found in the instructions supplied with the will affect proper operation of the pilot (if equipped). Do BVETTO fireplace. not install this gas appliance if minimum pressure is not The chimney damper MUST be fully opened when available.The maximum inlet gas-supply pressure is 10.5" burning the unit.The unit is designed to burn with yellow w.c. on natural gas and flames;thus adequate ventilation is absolutely necessary. 13"w.c.on L.P.gas.The L.P.source must be regulated. To comply with certification, listings, and building (Do not connect this appliance directly to an unregulated code acceptances, and for safe operation and proper L.P. gas tank - this can cause an explosion.) Do not performance of this burner system, use ONLY connect this appliance to a portable L.P. gas cylinder. BVETTO parts and accessories. Use of other controls, The gas piping system must be sized to provide parts, and accessories that are not designed for use minimum inlet pressure at the maximum fl ow rate(BTU/ with BVETTO burner systems is prohibited and will void hr). all warranties, certifi cations, listings, and building code Undue pressure loss will occur if the pipe is too approvals, and may cause property damage, personal small, or the run is too long. Gas supply pipe must be injury, or loss of life. Earthcore will not be liable for any 1/2" minimum interior diameter. If the gas line is longer damages caused by this misuse. than 20', a larger diameter line may be necessary. Refer to the NFPA 54 guidelines for further details. IMPORTANT:Solid-fuels shall not be burned in a fireplace This gas appliance and its main gas valve must be where a decorative appliance is installed. disconnected from the gas-supply piping system during any pressure testing of that system at test pressures in WARNING: If not installed, serviced, and excess of 1/2 psig. used correctly per these instructions, this product can This gas appliance must be isolated from the gas- cause serious personal injury, property damage, or loss supply piping system by closing the equipment shutoff of life. valve connected to the gas-supply line during any This appliance is only for use with the type of gas pressure testing of the gas-supply piping system at test indicated on the rating plate.This appliance is NOT FIELD pressures equal to or less than 1/2 psig. CONVERTIBLE for use with other gasses. CHECK GAS TYPE (natural or L.P.): The gas supply must be the same as stated on your burner system rating plate. If gas supply is different, DO NOT INSTALL. Contact your dealer for immediate assistance. INSUFFICIENT GAS PRESSURE WILL KEEP THE PILOT (IF EQUIPPED) FROM OPERATING PROPERLY. Table 1 - Product Specifications BTU Rating NATURAL GAS LP GAS Firebox Model Burner Model Log Set Model HIGH HIGH 80B36 BV-3BRN-24-NG/LP-MVKEI-GCRK AW024 74K 66K 80B46 BV-3BRN-24-NG/LP-MVKEI-GCRK AW030 74K 66K RECEIVED 12/23/2022 26 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Burner Parts List 1 6 s - — • ME !NM 5 4 7 3 — - 8 10 9 11 Y# ,� 4. 12 # Part # .Description 1 3BRN-24 24" 3 Burner 2 .LP-CONV * Propane Models Only 24" 3 Burner Propane Conversion Kit 3 6003V NG Control Valve 6003V-LP LP Control Valve 4 GM6KA Control Module 5 6K-WIR Wiring Harness 6 3V-PIL-24 NG Pilot Assembly 3V-PIL-24P LP Pilot Assembly 7 3V-BAT Battery Pack 8 •GCRK Remote Kit (Receiver & Handheld) 9 H P-R-B-10 Lava Rock 10 GLE-6B Black Embers 11 T102-9898-16 Flex Line 12 46-68 Gas Inlet Fitting Replacement parts can be ordered The log set is purchased and packaged from your local ISOKERN dealer. separately;contact your local ISOKERN rik �\/ �11�('� dealer when ordering. Refer to the ,P• �/ instructions included with the log set. 1 /23/2022 27 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 ISOKERN Gas Log Set - Wiring Diagrams IGNITION MODULE I :nraxi uu .cu. um PILOT ASSEMBLY 1a l' 4' ::‘ .641! !.. LI-t ' AL 14.1 UCN NOPINIMPIT E I I I I Lim1 ..• 44I , . WIRE HARNESS i241 aim WV INN tali - , ... . 11— BLACK "�`_ ' i BLACK r- . Ri .. , • %Ai ?.), I -. g • RED •'o GAS 1►IILVt 4. RED BROWN BROWN ` 7./..,,,,,......-"t.,-" BLACK 1 BLACK LINTEL Iti'''-''N'-'-'"-•.,,.. SWITCH -- - BAITER( HOLDER WIRE _ , �� - .-' ij • r!— '.111 LINTEL SWITCH WIRE I FIGURE 35 . ECEIVED 12/23/2022 28 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Burner Installation IMPORTANT: Ensure fireplace is clear of all debris NMI IIIIIP BURNER INSTALLATION: '4 1.Make sure the fireplace gas supply is turned off. 1 2.Locate the gas-supply stub inside the fireplace FIGURE 36 and remove the cap. When removing the cap make sure the stud does not turn, loosening the Location of Black& connection inside the wall. Brown wires from the ` .4111111111111 battery pack to connect spill switch 3.Center the burner from side to side and position MIMI wires it as close to the back wall of the firebox. Ideally, ---„,' the burner will be aligned directly under the flue \r I — a— damper. `_ "' 4.Disconnect one black-to-brown wire connection ,K and connect the black and brown wires to the Spill Switch wires. (Figure 35, 38, and 39) FIGURE 37 5.Use the 1/2" stainless steel flex line connector to connect the gas supply line to the gas inlet on the valve. When bending the flex line use proper •Ajwitch bending procedures to avoid kinkin the tubing box 6.Verify that connections are tight,then turn on 'the gas and check each connection using soap andwater solution. DO NOT USE AN OPEN FLAME FOR LEAK TESTING. The soap and water connection should be 50%water and 50%soap. Brush the /_ solution over the connections and check for Disconnect black/brown wires bubbles. Any leak must be corrected prior to proceeding with installation. FIGURE 38 7.Determine the valve system that is installed on the appliance,thenproceed with lighting the pilot Switch box wire Main harness wire pp g g 8.Before lighting the appliance make sure the heat IIII.II: I shield is placed back in the position it was when -I s the appliance was taken out of the box. • � rd Spill switch wires Connect spill switch wires RECEIVED FIGURE 39 12/23/2022 29 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 ISOKERN Gas Log Set - Burner Installation 9. Units with Power vent: Locate the two spill Spill switch wire switches and two power vent wires (not supplied ) coming out of the hole in the lower right side of the fireplace. Connect them to the free wires now coming from the main harness and battery box . See Figure FIGURE 40 40-42 Power vent wire Spill switch wire Connect spill switch and power vent wires 10. Install burner system batteries. Reference the INSTALLING/REPLACING BATTERIES section for details. 11. Place the switch box on the side, at the rear right corner of the fireplace. Figure 36&37 IMPORTANT: Ensure that the box wire remains away from the burner system and its flame during operation. ....._.0...IIISMMM......11P'''4.- FIGURE 41 1111111;Hower Batter box wire 12. Place the decorative heat shield over the battery box.AI. .. Connect power vent to switch box wire WIRING DIAGRAMTO SPILL SWITCH AND POWER VENT Ignition Motor wire module harness Q To Brown r i fireplac spill Switch Brown Female osMale . Black Black e Power vent Battery control box pack s Female Male es Male _,Female RECEIVED Note: power vent wires FIGURE 42 not supplied 12/2 3/2 0 2 2 30 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Burner Installation 13. locate vermiculite (3 burner and LP units only) • and the rock wool (Glowing Embers). Vermiculite is used for all propane units and for the ember burner on the 3 burner appliance. Open the vermiculite, e _ then evenly fill the entire ember pan area, _ Embers 14. Open the bag of rock wool, then spread it evenly PP- throughout the entire ember pan area. Tear the Lava Rock rock wool into smaller pieces and keeping it loosely packed will provide a better ember bed appearance. BATTERY LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly,a fire or explosion may result causing property damage,personal injury or loss of life. A_ This appliance is equipped with an ignition device that automatically lights the plot-DO NOT attempt to light the pilot by hand. B. BEFORE OPERATING,smell all around the appliance area'or gas.Be sure to smell next to the flop•because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS •Do not light any appliance. •Do not touch any electric switch;do not use any phone in your building. •Immediately call your gas supplier from a neighbor's phone Follow the gas supplier's instructions-If you cannot reach your gas supplier,call the fire department_ C. Use only the'emote to light the pilot.This valve will not operate if the pilot is not lit and stable. D. Do not use this appliance if any part has been under water.Immed ately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.Attempted operation may result in fire or explosion resulting in property damage.personal injury or loss of life. REMOTE LIGHTING CAUTION:DO NOT attempt to light the pilot by hand. 1 1 1r Note: If the remote does not function.and batteries with an adequate power level are installed.refer to the TRANSMITTER FUNCTION section. Note: Step 1 may not be required if previously done during an earlier lighting. OFF REMOTE I ONE I Locate the 3-position switch on the remote receiver and slide the switch to the REMOTE positron. 2 Locate the remote transmitter and press the ON button.The ignition rr sequence will begin.The remote receiver will emit an audible"beep-, then the igniter will begin to spark.After the pilot lights and is established. I ON I (12;) the valve will automatcally open and the burner will light_ Note: -he ignition sequence will take approximately S seconds. TIMER WARNING: If the pilot fails to light or if the burner fails to light / (within 5 seconds of pilot lighting),press the OFF button on OFF J O the remote transmitter and/or slide the switch to the OFF position.Allow five(5)minutes for any gas in the unit to SET dissipate,then repeat steps 1 and 2 above. IF YOU SMELL GAS,SEE STEP B ABOVE. If the pilot fails to light after several tries,turn all control/remote system components to OFF and contact a qualified professional service techncian. SHUTTING DOWN For remote shut down,cress the OFF button on the remote transmitter_ If remote is unavailable,sl de the switch on the remote receiver to the OFF position. t I 11 PILOT APPEARANCE e Periodically check the pilot for proper flame pattern.The pilot flame should encircle the generator tip,and is reset at the factory a fi If the pilot flame burns incorrectly:shut down completely and contact a ., qualified professional technician. . Battery Pilot IMPORTANT: For all valves, the air MUST be purged from the gas line before the pilot will light an Epr,r, The time needed to purge will depend on the length of the gas line to the unit and the amount o h unit or gas line was last used. It may take several minutes before all the air is purged and the pilot will light and burn properly. Reference the LIGHTING INSTRUCTIONS section in this manual. 12/23/2022 31 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 ISOKERN Gas Log Set - Burner Installation / Remote TRANSMITTER Oita— ® The transmitter operates on(2)1.5V AAA batteries. It is recommended that ALKALINE batteries always be used for this product. Be sure the batteries are installed with the(+) IO and(-)ends facing the correct direction,and are fully charged. O fir, CRP O ' KEY SETTINGS ( ) O .�,a. 1. ON--- rplin ( OFF ) �t 2. OFF--TuTurns applianceapace OF . a 3. TIMER Changesns unit fromON manualF mode to timer mode. ( ,E_.- ) A 4. SET--Adjusts timer setting. ( sET FRONT 30.C1. LCD-LIQUID CRYSTAL DISPLAY '� 1_ Display Indicates current room temperature. F 2. Fahrenheit or Celsius Indicates degrees Fahrenheit or Celsius. ' 3 3. Flame Indicates appliance is ON. 4. Room Appears when LCD screen is ON. ROOM SET TEMP 5. Temperature Appears during manual operation. 6. Set Appears when adjusting the desired timer setting_ F SETTING°FAHRENHEIT/°CELSIUS SCALE14? The factor;setting for temperature is°F.To change the displayed temperature scale,press the ON and OFF keys at the same time. Follow this same procedure to return to°F. ROOM TEMP MANUAL FUNCTION TIMER FUNCTION _ ON OPERATION: • Press the ON button to start the Press the ON key to turn the appliance. appliance ON. The flame icon • Press the TIMER button.The I ''� f '`:. will appear on the LCD screen) LCD screen will show the word 1!1! set. 35ET't ON MODE • Press the SET button until the desired time is reached(15 min.- SET MODE OFF OPERATION: 180 min. in.Thajuizttg 1`,F Press the OFF key to turn the increments).The max setting ' ' appliance OFF.(The flame icon will disappear from the LCD time is 3 hours • NOTE:The LCD display will flash n screenl the set time for 6-seconds,then OFF MODE start the countdown COUNT DOWN MODE • Press the OFF button to turn OFF the timer,and the appliance. LEARNING TRANSMITTER TO RECEIVER Each transmitter uses a unique security code. It will be necessary to press the LEARN button on the receiver to accept the transmitter security code upon initial use,if batteries are replaced, or if a replacement transmitter is purchased from your dealer or the factory,In order for the receiver to accept the transmitter security code,be sure the slide button on the receiver is in the REMOTE position;the receiver will not LEARN if the slide switch is in the ON or OFF position.The LEARN button in located on the front face of the receiver;inside the small hole labeled LEARN Using a small screwdriver or end of apaperclip gently press and release the black LEARN button inside the hole,When you release the LEARN button the receiver will emit an audible "beep"After the receiver emits the beep press the transmitter ON button and release.The receiver will emit several beeps indicating that the transmitter's code has been accepted into the receiver. RECEIVED 12/23/2022 32 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace ISOKERN Gas Log Set - Burner Installation/ Log Placement Burning Grand Canyon Gas Logs for any length of time will create soot; generally on the logs and firebrick. Soot is the result of incomplete combustion of the gas, producing dark dense material. Improper placement of the log set will contribute to excessive soot. It is critical to place logs according to the log placement diagrams.To clean off soot use an old tooth brush and gently rub away the soot. Periodic examination and cleaning of the venting system and the fireplace, including frequency of such examination and cleaning, by a qualified agency is recommended. AZ WEATHERED OAK 24' LOG PLAEMENT GUIDE • ( y eA. •//{ '��• /,/" "fi •�a'A`• 'w.. Yl 4 AZ WEATHERED OAK 30" LOG PLACEMENT GUIDE jiiillinrL _,.. ..,._ __.,.._ . : ,:_‘:taL . «et' • .,", '~ • '! � i: ce'' /23/2022 33 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 ISOKERN Gas Log Set - Troubleshooting BURNER SHUTTING DOWN DURING OPERATION A. Insufficient or excessive gas pressure Al.Check source gas pressure&checkwith local gas company. A2. Other gas appliances may be on the same gas line, dropping gas pressure to log set.Check pressures with everything operating to ensure adequate pressure. B. Log placement B. Reference the LOG PLACEMENT section in this manual for recommended log positioning. C. Pilot flame lifting off thermocouple/generator C. Check gas pressure (see section Al). D. Pilot (remote compatible) D. Contact your dealer for instructions on replacement. E. Blockages on burner E. Vacuum any lava granules or material that may have fallen onto burner pipe area. PILOT WILL NOT LIGHT A. Pilot flame lifting off thermocouple/generator A. Check gas pressure (see Section 1, Al of this table). B. Electronic spark not lighting pilot B. Check to ensure sparking when activated. Note:You may need to turn or press igniter several times to ignite pilot. See LIGHTING INSTRUCTIONS for your control valve. C. Igniter electrode wire loose C. Check wiring and reconnect any loose wiring. D. Gas supply off/manual shutoff valve closed D.Turn on gas supply or open manual shutoff valve. E.Air in gas line E. Bleed the gas supply line and repeat LIGHTING INSTRUCTIONS until air is removed. F. Pilot hood blocked F. Check for debris or dirt/Clean pilot LOW FLAME HEIGHT A. Gas pressure A. Check gas pressure (see Section 1, Al of this table). BURNER NOT BURNING EVENLY A. Burner orifice clogged A. Clean burner orifice. B. Remote set on low fl ame (if option available) B. Adjust flame with remote transmitter. C.Top burner lights; Cl. Check gas pressure. Can be caused by too small of a gas line (see bottomburner has delayed ignition. Section 1, Al of this table). C2. Low propane ODORS A. Gas leak A. Shut off gas, if possible. Follow instructions on front page. Have a qualified professional installer or the gas company correct all leaks. B. New home, new carpet, or new paint B. When these odors are drawn into the fireplace, this may cause objectionable odors. Thoroughly ventilate the area before restarting your log set. C. Damper closed C. Ensure that damper is open; . PILOT WILL NOT STAY LIT A.Valve won't hold A. Contact your dealer for instructions on replacement. B. Pilot hood not aimed at thermocouple B. Pilot hood bent; replace pilot or angle pilot hood properly so pilot flame hits thermocouple. C. Pilot line bent/kinked at connection to valve C. Replace pilot line. D.Thermocouple is loose D.Tighten thermocouple nut at gas control valve. (Do not over tighten.) E.Thermocouple cracked or worn out E. Replace thermocouple. F. Excessive down draft F. Install chimney cap / Outside chimney too close to other peaks / Check chimney flue for proper height/ Poorly designed chimney. BURNER WILL NOTTURN ON A. System deactivated due to closed damper A. Open damper. RECEIVED B. Low/dead batteries in remote transmitter B. Replace batteries as needed (if applicable). AND/OR remote receiver/switch box (select models only) 12/23/2022 34 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace EcoDamper Draft System General Information & Components The environmentally friendly ENERVEX EcoDamper Component Part# Description System is the first completely automated draft and damper system for use with gas fireplaces.The EcoDamper System quietly manages a perfect draft and prevents conditioned air from escaping through the chimney when the fireplace is not in use. It eliminates the need for glass doors, opening many new design 101.0299.1200 AS 9 Chimney Fan options while allowing for a larger view area of the fire and a more natural look. The system consists of the RS Chimney Fan, the Mechanical Fireplace Damper (MFD), the ADC100 Control and the PDS1 Proven Draft Switch. RS Chimney Fan _ Made of high quality, recycled cast aluminum, RS Chimney Fans keep the perfect draft for a long time.The 216.0100.1210 MFD Mechanical Fireplace Damper fan features a quiet, enclosed motor and is recommended to be used with gas or oil fireplaces, stoves, ovens, furnaces, water heaters, BBQs, and pizza ovens. MFD Mechanical Fireplace Damper The low-profile Mechanical Fireplace Damper (MFD) is an accessory to be used in conjunction with an ADC100 a° control and a chimney fan as part of the EcoDamper 302.0100.1200 ADC100 Draft Control and Intellidraft System. This damper prevents conditioned (includes PDS-1) • • air from escaping through the chimney when the fireplace is not in use and eliminates the need for glass doors. ADC100 Draft Control ,..., . The ADC100 Control,for gas appliances, has pre-and post-purge features, an integrated damper relay and 301.1001.0000 PDS-1 Proven Draft Switch (included with ADC100) includes a draft switch that shuts the appliance off when there isn't enough draft, protecting your family from dangerous flue-gas. PDS1 PROVEN DRAFT SWITCH Use the PDS1 Proven Draft Switch to provide protection from insufficient draft.When there is an unsafe draft, the switch shuts down the gas-fired appliance or fireplace. RECEIVED 12/23/2022 35 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 ECODAMPER System - Installation Installations must conform to requirements of the 2. Before servicing or cleaning the unit, switch off at authority having jurisdiction. Where required by the service panel and lock service panel to prevent power from authority having jurisdiction, the installation must also being switched on accidentally. conform to the Standard for Draft Equipment and The National Fuel Gas Code, ANSI Z223.1/NFPA 54. 3. Installation work and electrical wiring must be done bya All electrical wiring must be in accordance with the qualified person(s)in accordance with applicable codes and requirements of authority having jurisdiction or, in the standards. absence of such requirements, with the National Electrical Code, NFPA70. 4. Follow the appliance manufacturer's guidelines and This installation manual does not contain any system safety standards such as those published by the National design documentation. System design documentation is Fire Protection Association (NFPA), and the American available from any authorized ENERVEX representative. Society for Heating, Refrigeration and Air Conditioning Accessories, fans, and variable frequency drives are not Engineers (ASHRAE), and the local code authorities. covered by this manual. Please refer to these component's individual manuals. 5. This system must be grounded. TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, MECHANICAL DRAFT SYSTEM FOR A GAS-FIRED OR INJURY TO PERSONS, OBSERVE THE FIREPLACE WITH DAMPER AND SAFETY SYSTEM FOLLOWING: PER NFPA 54/IFGC 1. Use this unit in the manner intended by the manufacturer. If you have questions, contact the Application manufacturer at the address or telephone number listed on This installation shows a combination fireplace and the front of the manual. damper system. The ADC100 control monitors fan and damper operation and the safety system. No adjustments are necessary after the system is installed and commissioned. The ADC100 does not have to be visible and can be installed in the attic. (Figure 55) Chimney Fan Jill juminProven Draft Switch is part of ADC100 control. SEQUENCE OF OPERATION nction Junction V1. During commissioning, the fan speed is set using the MFD Automated Box potentiometer located on the ADC100 control board. Damper .11. 2. When the gas igniter is activated, the fan speed Chimney increases, and the damper begins to open. Once the Probe J damper is fully open and the proven draft switch closes,the fan returns to the speed setting of the potentiometer and the ADC100 releases the gas valve. PDS, Proven ADC100 Draft Switch 3. If proper draft is not maintained, the ADC100 will 4 O increase fan speed gradually until the PDS closes. If the PDS — has not closed 10 seconds after the fan reaches 100%speed, I the ADC100 will shut off the gas valve and go into alarm r mode. If the PDS closes while in alarm mode, the fan will resume the original speed setting. +/- 4. O nce the fireplace is turned off,the fan will continue 44 to operate fora set post-purge time(adjustable between 0-10 minutes) to remove any remaining products of Gas combustion before shutting down.The damper closes 10 Valve seconds after the fan is shut off. - ' 5. In case of a mechanical or electrical fail C NED will shut off the gas valve. FIGURE 43 12/23/2022 36 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace ECODAMPER System - Wiring Diagram FAN MOTOR s o 7 C-c 7 n p oY G I I - 7 OW O I I I x I ADC 100 1 1 1 1 I1 11 0 AUX 2 All I t)AI/PER VFD AV%2 AV% I �--F-1 N AC Al FAN OUT 14YDC IN IN PDS IN RELAY I PROVE RELAY CTRL OUT OUT /d /d l n 0 26 25 29 30 D 1 2 3 4 5 6 7 8 0 0 9 10 11 12 13 Ia 15 16 17 18 19 20 21 0 0 22 23 000I 000 00 00 000 00000000 00 FIGURE44 1 L J 1 1 1 - 1 1 1 i i i i 1 1 LLI I 1 ,�� 1 POTIER SU L PPLY '„4LL 51YITCJ U I 6 120 VAC OR RECEIVER L J 1 1 L 0 0 0 �1ust Be Dedicoted No NC 0 PDS—1 FIREPLACE EXTERNAL J L____ P$ER SUP Lt GAS VALVE N_i i VAC GENERATOR 1 1 I HOT CO' N LI C NO NC 1TH TRa 0 0 0 0 0 DAMPER GAS VALVE ACTUATOR OR IGNITION RECEIVED 12/23/2022 37 ASPEN BUILDING DEPARTMENT Earthcore Industries BVETTO B-Vent Gas Fireplace 12/2021 Notes RE1,-;EIV D 12/23/2022 38 ASPEN BUILDING DEPARTMENT Earthcore Industries 12/2021 BVETTO B-Vent Gas Fireplace Registration Card Please tear out along dashed lines and send to: Earthcore Industries Attn:Technical Department 6899 Phillips Industrial Blvd Jacksonville, FL 32256 Dealer Date of Purchase: Date Of Installation: Address: City, State, Zip: Phone No.: Fireplace Size (Circle One): BVETTO 36" (80B36) BVETTO 46" (80B46) Gas Type (Circle One): Natural Gas Propane Fireplace Serial Number: (Located on Rating Plate Inside Fireplace) Buyer: Address: City, State, Zip: Phone No.: Installed By: Address: City, State, Zip: Phone No.: RECEIVED 12/23/2022 39 ASPEN BUILDING DEPARTMENT /I"'*�� ;;i.:(j i' �gig Q11I�.. \ 'i�``� .01 I(''.IQI.I�.. �� ;;S: vjj 1 li''�1♦�.� ; ♦ o;;;;: Si.. I''�IQ,,I�1♦ V. J*w.;SY-VON 47 P��i0�i�:..':.•:k�`1 •• CrP 4%, i�:..:...:'�`111. .": :: 44 i:`•..:q:�k.4. A.l..... . �/0�i::.. ':...i � �.J!.......tr.`..i0�ikA •:ili �i 1,11: % A arrantp & Mt5ttatmer % �" Isokern BVETTO B-Vent Gas Fireplace ",: ,4l. Earthcore offers a Lifetime Warranty for all Isokern components, to be free from defects in materials that negatively 1l � affect system performance from the date of purchase, subject to the terms and conditions of this limited warranty. ‘ :. This warranty covers only the above stated components.THIS WARRANTY DOES NOT COVER DRAFTING, SMOKING •�,. OR PUFFING OF THE FIREPLACE SYSTEM. Factors beyond the manufacturer's control affect fireplace drafting, K :11! smoking,and puffing, and ISOKERN cannot guarantee these aspects of performance. 'll :• EXCLUSIONS AND LIMITATIONS ` � ! **. This Lifetime Warranty applies only if the Isokern Product is installed in the United States and Canada and only if "'' \' operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with 1 j•,•.:: all applicable installation and building codes and good trade practices.This warranty is non-transferable and extends to .�• ; ;` �/ the original owner only.The following do not carry the Lifetime Warranty but are warranted as follows: • Burner—The BVETTOgas logburner has a oneyear warrantyagainst any ":ir�,,N g performance defects. ``: o e.- Gas Logs—The BVETTO gas logs have a one year warranty against breakage;except breakage due to mishandling or 1/1,..•. negligence. j�' Control Valve— If the BVETTO gas log burner was purchased with a gas control valve, the gas control valve has a one '''� ' •% year warrantyagainst any � :'.. ... g performance defects. - �: ‘ila• Gas Logs — All painted surfaces that get wet due to rain, flooding, household pets, wild animals or birds, or get i!.% damaged due to negligence or disaster, have no warranty. %1 ;. 1(; Accessories— Embers and lava coal that get wet due to rain, flooding, household pets, wild animals or birds, or get 0, j� damaged due to negligence or disaster, have no warranty. t ;. �� • s'." Parts not otherwise listed carry a 90 day warranty from the date of installation. ' =� —zi a component is nd to be ve under he terms of s warranty the o whom s warranty is i�� shall notify Earthcore, 6899 Phillips II dusttrialtBlvd, Jacksonvlille, Florida 32256rty ntwriting, byl registered mail, witthinn pips,4 s€ thirty(30)days following the discovery of the defect within the lifetime warranty period.The notice shall contain (1)the • • date of purchase; (2)place of purchase; (3)address of installation; (4) name,address and phone number of the owner; "= . \` and •(5)a brief description of the defect. •./. •$%% Earthcore, or any division thereof, is not responsible for any labor costs or indirect costs incurred for the replacement \ . ��� i3_ of defective components. Alt!d �•� Earthcore is not responsible for misuse or mishandling of components. Nothing in this warranty makes Earthcore, or . ��':• any division thereof, liable in any respect for any injury or damage to the building or structure in which the fireplace or '��\' eg chimney system has been installed or to persons or property therein arising out of the use, misuse, or installation of : ":• properly manufactured ISOKERN product. ' EARTHCORE,OR ANY DIVISIONTHEREOF,SHALL NOT BE HELD LIABLE FOR ANY INCIDENTAL ORCONSEQUENTIAL ."." DAMAGES OR EXPENSES ARISING OUT OF THE USE OF THE FIREPLACES OR CHIMNEY SYSTEMS. ALL SUCH ••••• ; DAMAGES AND EXPENSES ARE HEREBY EXCLUDED. s = !�i : a:.34 ::.— This warranty is null and void when the fireplace or chimney systems are not installed pursuant to the installation :-•: l;• instructions provided by Earthcore or local building codes have not been followed completely. ';� pt/ This warranty applies only to those fireplace and chimney systems installed in the continental United States and �``' = ? Canada. If any part of this warranty is found to be unenforceable, the remaining parts shall remain in force and effect. �:��•� . /—zi��i EARTHCORE HEREBY DISCLAIMS ALL GUARANTEES AND WARRANTIES, EXPRESS OR IMPLIED, BEYOND THE it: ��' WARRANTIES SET FORTH HEREIN. ` `li Ali:, I/�� eart heore s. �.. 6899 Phillips Industrial Blvd. •Jacksonville, FL 32256• 904.363.3417 •f: 904.363.3408• earthcore �,�E;G,,1 E `• /,i 11: :i '/�:t �� ': I:/ 17.7.7.7.t 141: : ;./` 1.771.:tilt :MSC ice:: .. $ -:a ;? lal`. `�•�. I 11 �•.. - I/ 11`�. ... i�11 `�. I/ 11``,. I//11 `�.•.... I/ 11`�. ... I//11 �. I/ 11 `�. I/ 11 `�. I� /1 `�. ./ �p���i1 .0.Ii,'.��`tt, k .4'.I:::'w��i1 1�I''e�`tt, 1��1�.9:•' 1 it `.;.!Ii,R ./ 1k��1�::.��:.�i1 �I;!Ii,'�.2. sk. tif:V;.��1 �1;.gRVt /��.ir Q.. � I � ..I� .!.I�O� `:%�� �e./ Sl.I�i��.!:. `,.� Vitt.,� .S:_ �i��.!! �%� �!:I eQI.�....��._.I��.,�2,���.!./ MKG1004_0817 BUILDING DEPARTMENT