HomeMy WebLinkAboutFile Documents.1263 Bunny Ct.0047-2022-BRES (6) RECEIVED r-AuWirl INSTALLATION MANUAL PCOCOMLLVilliAla 04/05/2022 mP INSTALLATION INSTRUCTION; REQUIRED ON SITE TOWN &COUNTRY ASPEN LUXURY FIREPLACES BUILDING DEPARTMENT AT TIME OF INSPECTION The Architectural Series BY TOWN & COUNTRY CONFIGURATION Sincle Sidec 4: if • FOR YOUR SAFETY This is a decorative product and is not intended Installation and service must be performed by to be used as a heating appliance. a qualified installer, service agency or the gas supplier. This appliance is suitable for installation in a WHAT TO DO IF YOU SMELL GAS bedroom or bed sitting room. • Do not try to light any appliance. • Do not touch any electrical switch. This appliance may be installed in an aftermarket • Do not use any phone in your building. permanently located, manufactured home (USA only) • Immediately call your gas supplier from a or mobile home, where not prohibited by local codes. neighbour's phone. Follow the gas supplier's This appliance is only for use with the type of instructions. gas indicated on the rating plate. This appliance • If you cannot reach your gas supplier call is not convertible for use with other gases, the fire department. unless a certified kit is used. Do not store or use gasoline or other WARNING: If the information in these instructions is flammable vapors and liquids in the vicinity of not followed exactly, a fire or explosion may result this or any other appliance. causing property damage, personal injury or death. �hr.Rry We endorse NFI NATIONAL INSTALLER: Leave this manual with the appliance. c LC us FIREPLACE CONSUMER: Retain this manual for future reference. II INSTITUTE F-1_T'N'l, A CENT FiCATv04 AGENCY 04/05/2022 310521-56 Architectural Series Aim 81 BUILDING DEPARTMENT RECEIVED III O4/VJ/ LVLL " `� Table of Contents ASPEN BUILDING DEPARTMEN Contents Table of Contents 2 Caution 3 Safety 3 Important Note for the Commonwealth of Massachusetts 4 Congratulations on your Town &Country purchase 5 Installation Requirements/Appliance Specifications 5 Installation Requirements 5 Vent Terminal Minimum Clearances 6 Minimum Clearances to Combustible Material 7 Appliance Dimensions 8 Top Intake model 8 Bottom Intake model 9 Btu Values and Weights 10 Minimum Clearances to Combustible Material 10 Locating the Unit 11 Framing and Finishing 13 Framing 15 Facing Material 16 Venting Configuration 17 Venting plenum 17 NOTE: Plenum must not be shared with other appliances. 17 Venting Specifications 19 Air Intake 21 Optional Motorized Damper 23 Power Vent 24 Power Vent Dimensions 25 Vertical Installation 25 Horizontal Installation 26 Vent Terminal Clearance 27 Power Vent Wiring 27 Flush Mount Power Vent Dimensions 28 Framing the Flush Mount Power Vent 29 Flush Mount Electrical Connection 30 Baffle Adjustment 31 Black Glass Option Installation 32 Glass Burner Media Installation 34 Front Glass Plates Installation 35 Inner Glass Plate Installation 35 Outer Glass Plate Installation 37 Electrical Connection 38 Electrical Diagram 39 LED Strip Replacement 40 Removing an LED section 40 Control Panel Installation 42 Gas Connection 43 Gas Pressure Requirements 43 Lighting Instructions 44 Maintenance 45 GLASS PANEL: 45 ANNUAL INSPECTION: 45 Periodically: 45 Replaceable Parts 4 Rating Label ECE IVE t 04/05/2022 r TOWN&c Op eTR= 100005181 2 Architectural Series 310521-56 p aE ASPEN BUILDING DEPARTMENT RECEIVED Eviorw) FORCOMCOMPLIANCE O4/UJ/ LULL aution BUILD h �iance and its individual shut off valve must be disconnected from gas supply piping system during ressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Do not use the fire feature if any part has been under water. Immediately call a qualified service technician to inspect the fire feature and to replace any part of the control system and any gas control which has been under water. NFI NATIONAL A WARNING:This product can expose you to chemicals FIREPLACE 6 INSTITUTE including ceramic fibers, which are known to the State A CERTIFICATION AGENCY of California to cause cancer, and carbon monoxide, which is known to the State of California to cause We recommend that our gas hearth birth defects or other reproductive harm. products be installed and serviced For more information go to www.P65Warnings.ca.gov. by professionals who are certified in the United States by the National Fireplace Institute®(NFI) as NFI Gas This warning is applicable to all Specialists Pacific Energy Fireplace Products Safety Any grill, panel or door removed for servicing the unit must be replaced prior to operating. Failure to do so may create a hazardous condition. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures. This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. RECEIVED 04/05/g22 310521-56 Architectural Series 3 100005181 =v8., °;;cP ASPEN BUILDING DEPARTMENT RECEIVED IIE 04r)nporta �. `ate for the Commonwealth of Massachusetts — FAS achusetts Rules and Regulations 248 CMR 5.08: BUILDING DEPARTMENT (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling,building or structure used in whole or in part for residential purposes,including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven(7)feet above finished grade in the area of the venting,including but not limited to decks and porches,the following requirements shall be satisfied. 1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment,the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed,in addition,the installing plumber or gas fitter shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling,building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors. a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,the hard-wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation,the owner shall have a period of thirty (30)days to comply with the above requirements;provided,however,that during said thirty(30)day period,a battery operated carbon monoxide detector with an alarm shall be installed. 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certified. 3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight(8)feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half(1/2)inch in size,"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS" 4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection,the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2) (a) 1 through 4. (b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4. 1. The equipment listed in Chapter 10 entitled"Equipment Not Required To Be Vented"in the most current edition of NFPA 54 as adopted by the Board;and 2. Product Approved side wall horizontal vented gas fueled equipment installed in a room or structure separate from the dwelling,building or structure used in whole or in part for residential purposes. (c) MANUFACTURER REQUIREMENTS—GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment,the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components;and 2. A complete parts list for the venting system design or venting system. (d) MANUFACTURER REQUIREMENTS—GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fuel gases,but identifies"special venting systems';the following requirements shall be satisfied by the manufacturer. 1. The referenced"special venting system"instructions shall be included with the appliance or equipment installation instructions;and 2. The"special venting systems"shall be Product Approved by the Board,and the instructions for that system shall include a parts list and detailed installation instructions. (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment,all venting instructions,all parts lists for venting instructions,and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. RECEIVED 04/05/2022 r TOWNocOp ATR= 100005181 4 Architectural Series 310521-56 p RE ASPEN BUILDING DEPARTMENT RECEIV EVIEWE-1 ED R.- o4T7s7roDon lations on your Town & Country purchase - ASPEN BUILDBUILDIttaffilikitiilikaUral Series Zero Clearance linear appliance has been professionally installed by: Dealer name: Phone Number: If you discover any problems with your linear appliance, contact your dealer immediately to have the unit repaired. Caution: Do not attempt to repair the linear appliance because you may cause injury to yourself or others, and risk causing damage to the unit. Before operating your linear appliance carefully read this manual and pay close attention to all Safety Warnings. The manual contains important information on the unit's safe operation and maintenance. - Installation Requirements/Appliance Specifications Town and Country Architectural Series linear appliance. Specifications • This unit has been tested to CSA P.4.1 specifications. • Single wall (min. 26 ga) galvanized venting. (Zero clearance) • 120VAC /single phase. • 24VAC Honeywell direct ignition valve system. • Power vented only. Programmed with pre and post-purge safety functioning. Certified to use provided Town & Country power vent only. • Horizontal or Vertical Termination. • Zero clearance unit (no non-combustible board required). • 12" rigid exhaust - 150ft max length plus up to 6 elbows. (Zero clearance) • 7" rigid intakes - (All bottom intake models) 150ft max length plus up to 6 elbows. (Zero clearance) • 10" rigid intakes - (All top intake models) 150ft max length plus up to 6 elbows. (Zero clearance) Installation Requirements The fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes. Only qualified (licensed or trained) personnel should install this product.In the state of Massachusetts, only a licensed Plumber and Gas Fitter may install this product.REC""�E IVED 04/05/ 22 Low 310521-56 Architectural Series 5 100005181 y Rod NTR s ASPEN BUILDING DEPARTMENT RECEIVED II E" O4/u /LULL 411nirent Terminal Minimum Clearances ASPEN BUILDING DEPARTMENT _❑ f � H g - jLECD TT FID g �� �r LOSED BLE I!!!!L!. OPEN- I \ g T g _ AVFJ / } AREA WHERE TERMINAL r,El V❑VENT TERMINAL QA AIR SUPPLY INLET IS NOT PERMITTED GAS METER Figure 1: Vent terminal minimum clearances. POWER VENT (SKU 22080040) Canada1 US2 A= Clearances above grade,veranda,porch,deck,or balcony. 12 inches(30 cm)min. 12 inches min. B= Clearance beside or below a window or door that may be opened. 12 inches(30 cm)for 9 inches for appliances> appliances<100,000 10,000 Btuh and<50,000 Btuh., Btuh. 36 inches(91 cm)for `12 inches for appliances appliances>100,000 >50,000 Btuh., Btuh. C= Clearance to permanently closed window recommended to prevent condensation 12 inches(30 cm) 12 inches on window. D= Vertical clearance to ventilated soffit located above the terminal within a horizontal 24 inches(60 cm)min. 24 inches min. distance of 2 feet(61 cm)from the center line of the terminal. E= Clearance to unventilated soffit from the center line of the terminal. 24 inches(60 cm)min. 24 inches min. F= Clearance to outside corner. 6 inches(15 cm)min. 6 inches min. G= Clearance to inside corner from the center line of the terminal. 24 inches(60 cm)min. 24 inches min. H= Clearance to each side of center line extended above meter/regulator assembly. 3 feet(90 cm)min. within a height of 15ft (4.5m)above the meter or regulator assembly 1= Clearance to service regulator vent outlet. 3 feet(90cm)min. J= Clearance to non mechanical air supply inlet to building or the combustion air inlet 12 inches(30 cm)< 9 inches for appliances> to any other appliance. 100,000 Btuh. 10,000 Btuh and<50,000 36 inches(91)cm> Btuh. 100,000 Btuh 12 inches for appliances >50,000 Btuh. K= Clearance to a mechanical air supply inlet. 6 feet(1.8 m)min. 3 feet(90cm)min. above if within 10ft(3m) horizontally L= Clearance above paved side-walk or a paved driveway located on public property A 7 feet(2.1 m)min. M= Clearance under veranda, porch,deck,or balcony $12 inches(25 cm) $12 inches min. min. RECEIVED 04/05/2022 r TOWN&COp COUNTRY 100005181 6 Architectural Series 310521-56 LUXURY FIREPLACES ASPEN BUILDING DEPARTMENT RECEIVED 04/0E41 M •' i''OWER VENT(SKU 22080041) ASF;-i,j Canadal US2 BUILD CPC(]i4 1parar`ces above grade,veranda, porch,deck,or balcony. 12 inches(30 cm)min. 12 inches min. B= Clearance beside or below a window or door that may be opened. 12 inches(30 cm)for 9 inches for appliances> appliances<100,000 10,000 Btuh and<50,000 Btuh., Btuh. 36 inches(91 cm)for *12 inches for appliances appliances>100,000 >50,000 Btuh., Btuh. C= Clearance to permanently closed window recommended to prevent condensation 12 inches(30 cm) 12 inches on window. D= Vertical clearance to ventilated soffit located above the terminal within a horizontal 20 inches(51 cm)min. 20 inches min. distance of 2 feet(61 cm)from the center line of the terminal. E= Clearance to unventilated soffit from the center line of the terminal. 20 inches(51 cm)min. 20 inches min. F= Clearance to outside corner. 6 inches(15 cm)min. 6 inches min. G= Clearance to inside corner from the center line of the terminal. 20 inches(51 cm)min. 20 inches min. H= Clearance to each side of center line extended above meter/regulator assembly. 3 feet(90 cm)min. ** within a height of 15ft (4.5m)above the meter or regulator assembly 1= Clearance to service regulator vent outlet. 3 feet(90cm)min. ** J= Clearance to non mechanical air supply inlet to building or the combustion air inlet 12 inches(30 cm)< 9 inches for appliances> to any other appliance. 100,000 Btuh. 10,000 Btuh and<50,000 36 inches(91)cm> Btuh. 100,000 Btuh 12 inches for appliances >50,000 Btuh. K= Clearance to a mechanical air supply inlet. 6 feet(1.8 m)min. 3 feet(90cm)min. above if within 10ft(3m) horizontally L= Clearance above paved side-walk or a paved driveway located on public property A 7 feet(2.1 m)min. ** M= Clearance under veranda, porch,deck,or balcony $12 inches(25 cm) $12 inches min. min. 1) - In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) - USA- In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code, ** Clearance in accordance with local installation codes and the requirements of the gas supplier A A vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* $ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor Minimum Clearances to Combustible Material This appliance is a zero clearance fire feature. Combustible material may be use to frame the unit in. Venting for this unit is also zero clearance. Combustible material is permitted to come into direct contact with venting material. RECEIVED 04/05/ 22 310521-56 Architectural Series 7 100005181 TOWN&ROUNTRs vr ASPEN BUILDING DEPARTMENT RECEIVED II O4/VD/LVLL Appliance Dimensions ASPEN Top Intake model BUILDING DEPARTMENT 3' 4' 5' 6' 7' 8' A 47 7/8" 59 7/8" 71 7/8" 83 7/8" 95 7/8" 107 7/8" B 53 1/4" 65 1/4" 77 1/4" 89 1/4" 101 1/4" 113 1/4" C 37 1/8" 46 1/8" 58 1/8" 70 1/8" 82 1/8" 94 1/8" Glass Height 1 16" 24" 32" D 16" 24" 32" 22" e 10" E 52 1/8" 60 1/8" 68 1/8" _ t B aft 1I ' JI e I 22 5/8" C o 11 7/8" I-T I I—T I I-T1 28"i 11 1/8" - • 4ft y 0 ] 0 1 .. 40" t . : �-. 0 17 7Norr l/8" • 5ft [� A 40" - ,-J 81- i 5/8" —� 22 5/8" 21" 6ft * ° 40" • • • 0 ..Ai\- 0 . 7ft [ty) E Nur 48" a 0 0 al- 0 . AINI U " L 8ft R=l RECEIVED 04/05/2022 r TOWN&coUNTRY 100005181 8 Architectural Series 310521-56 p aE ,. E, ASPEN BUILDING DEPARTMENT RECEIVED ley/11EN-) aoricookarinvia 04/05/2022 i iMP Bottom Intake model ASPEN BUILDING DEPARTMENT 3' 4' 5' 6' - 7' 8' A 47 7/8" 59 7/8" 71 7/8" 83 7/8" 95 7/8" 107 7/8" B 53 1/4" 65 1/4" 77 1/4" 89 1/4" 101 1/4" 113 1/4" C 50 1/4" 62 1/4" 74 1/4" 86 1/4" 98 1/4" 110 1/4" Top View(Vent) 0 11 7/8" "153 Q a4 Bottom View(Air Intakes) 12" mom 12" mr_� l m 3ft B 1 1/2'— I—r. . . . . . . . .0 —I Etta G�� ali . . . . . . . . . .1 .......... 07" 15" — — 15" ° l J' 0 °. Oft '. D �, ._ ' v u A —:: . • • 21 21 •�/ ur '� "o � -i �lE ° 5ft Glass Height_ 16" 24" 32" D 16" 24" 32" 21" — 21" ff E 45 1/4" 53 1/4" 61 1/4" rt. r, F 50 5/8" 58 5/8" 66 5/8" ° I 0 _ ° .• 6ft �f u 15 1/2" 1 1/2"—. k g 18" 18" 18" r, ^ r, o • . 1 7ft . �, .. .. E F 24" 18" 24" • 2 ^ - - ^ -. 17 7/8' ° 0 O ° 8ft 0 5/8"—f —181/2"— RECEIVED 04/05/ 22 Low 310521-56 Architectural Series 9 100005181 y 8 Rod NTR s Nir ASPEN BUILDING DEPARTMENT RECEIVED Mt20 ZD 04/07,/!0!! Btu Values and Weights ASPEN BUILDING DEPARTMENT Single Side 3FT 4FT 5FT 6FT 7FT 8FT BTU/HR 48000 64000 80000 96000 112000 128000 16" Glass 374 440 522 591 664 727 Weight lbs 24" Glass 422 495 585 661 737 814 Weight lbs Minimum Clearances to Combustible Material This appliance is a zero clearance fire feature. Combustible material may be used to frame this unit in. Venting for this unit is also zero clearance. Combustible material is permitted to come into direct contact with venting material. RECEIVED 04/05/2022 r rowN&cop eTRY 100005181 10 Architectural Series 310521-56 p aE ASPEN BUILDING DEPARTMENT RECEIVED I III Faiourtamwate Locating the Unit O4/VJ/LVLL B j e the Architectural Series Linear Appliance is power vented, it can be located in a variety of BUlLDWe A Consideration must be taken for the location of the fresh air intake and the power vent unit venting. A site fabricated platform capable of supporting the appliances weight may be constructed to elevate the viewing area to the desired height, and so that it can accommodate the fresh air intakes (if bottom vented), gas supply and electrical supply. / / /n øn Bottom Horizontal / Power Vent Intake Termination Vertical Termination Models Vertical Venting &Termination U. Supporting wall ,��������������/////�����i� Facing Material ,.7.i ... r /:. Power Vent 1 A _:'.. .. , ....:7.,__ e, , . / . , . - . . -�--- - Site Fabricated \ J I F.J. / Elevated Platform //////////// %//////;ll/////////////////��/////////////////; I Air Intake \ J \ I Figure 2: Location options for Bottom Intake models. RECEIVED 04/05/0,22 310521-56 Architectural Series 11 100005181 TOWN&COUNTRY LUXUES ASPEN BUILDING DEPARTMENT RECEIVE AIE08/1W peacatmatima 04/05/2022 1,.9 ASPEN BUILDING DEPARTMENT r_,,,,,, r A i / Horizontal Termination / Power Vent //n ) 1 Top C1ir/ ; ) ` I\ ) Vertical i, ) Termination Intake r/ ) /'': ) Models %/ ////A Vertical Termination Supporting wall Facing Material Air Intakes ,,,-.4- .is . ,„„„„ ,„.,„„, „. --: rm ,-Th Power Vent C]; j . ez-Al , /-/- ,, d Site Fabricated , .• Elevated Platform /7//////////// //.l .7 i////////////// //////////////////.:I A Figure 3: Location options for Top Intake models. RECEIVED 04/05/2022 V TOaCOUNTR 100005181 12 Architectural Series VXupYWN . aE . V 310521-56, ASPEN BUILDING DEPARTMENT RECEIVED 1av/l1 O4/ Un/LULL Framing and Finishing ASPEN BUILDING DEPARTMENT Screws must approach the wood studs through the metal framing from the center of the appliance Bottom . Intake - . . ; 0 Models 0 • • • Figure 4: Stud securing points for bottom intake models. Before framing and finishing, there are two important points to keep in mind: 1 . When securing the top of the unit to the wooden studs, the screws must come through the metal framing from the center of the unit (Figure 6). 2. Facing material can be secured directly to the front and sides of the unit except in the areas indicated in this example by Figure 45. Each model will have its own specific areas in which screws must not be driven into. Facing material may be screwed directly into the body of the appliance with the exception of areas indicated. . . 1 in. below rivets _ . ' — . 3in. above trim — ; .— , — , • , . ; Do not use screws in these areas 3in. below trim — : • — • — • . • • • . • • • : Recessed area Recessed area • (Front and rear) — — • - �� FzECFIVED Figure 5: Facing attachment area for Bottom Intake models. 04/05/g22 310521-56 Architectural Series 13 100005181 rowp&Rod NTR ASPEN BUILDING DEPARTMENT RECEIVES r1IEW1r18/2022) peacatraiima 04/05/2022 m' ASPEN Framing material can be screwed directly to the attachment BUILDING DEPARTMENT rim around the top of the appliance. 4e4/:/ 4111Pd Top Intake • 41.0 • Models r� • Figure 6: Stud securing points for Top Intake models. Before framing and finishing, there are two important points to keep in mind: 1 . When securing wooden studs to the top of the unit, the screws can be secured through any part of the upper fastening area surface (Figure 6). 2. Facing material can be secured directly to the front and sides of the unit except in the areas indicated in this example by Figure 77. Each model will have its own specific areas in which screws must not be driven into. Facing material may be screwed directly into the body of the appliance with the exception of areas indicated. I I 1 in. below rivets I — • • 3in. above trim - - - . Do not use screws in these areas • 3in. below trim — — — . Recessed area [I O (Front and rear) — L _ram � , • et_ IVED Figure 7: Facing attachment area for Top Intake models. 04/05/2022 r T,.=„6 ouNTRv 100005181 14 Architectural Series 310521-56 �VXupY. .E .�E= ASPEN BUILDING DEPARTMENT RECEIVED n`208,:i2ozz4u�a FORCOOMINUNCE � ene 04/WA2 ;.MP \SEEN BUILfNu utrHn!Mr IV (Studs shown are for demonstration purposes only and do not indicate how the finished struc- ture should be constructed) Drywall or Facing Material 2X6"Stud • Drywall or Facing Material Recessed Area (front & rear) 2X4"Stud Site fabricated platform (must support weight of appliance-see page 11). (Platform shown is for demonstration purposes only and does not indicate how the structure should be constructed) Figure 8: Framing and facing. NOTE: The architectural series fireplaces have a large amount of venting air being drawn through them. It is recommended to insulate the framework that encloses the venting above the fireplace with a sound-proofing insulation such as mineral wool, to reduce any air flow white noise. RECEIVED 04/05/ 22 310521-56 Architectural Series 15 100005181 TOWN&COUNTRY LUXUES ASPEN BUILDING DEPARTMENT RECEIVED aw 04Fikrn'( 19lat�rial — d'ASrE-J\N1 mILDmp w- unit requires no clearance to combustible material, drywall or other facing material can be affixed directly to the surface of the unit. Using standard 2x4's and 2x6's in the framing process allows for the edge of 1/2" drywall or other facing material to fit into the channels which make up the perimeter of the exterior glass sheets (Figure 9 and Figure 10). To Power Vent 1/2"Drywall or Facing Material 2X6"Studs o • • s e Channels will accommodate 1/2" Drywall or • Facing Material . Figure 9: Leading edge of drywall. NOTE: The architectural o o series fireplaces with the F• • exception of the peninsula 2X4°StudsY _ models are capable of bearing up to 1000Ibs of 1/2"Drywall or Facing Material facing material weight. Up to 1 inch stone may be used. An architectural series Site fabricated platform fireplace is not to be used as a load bearing structure. Figure 10: Left side framing and facing view. 04/05/2022 r row Nacp:c ` 100005181 16 Architectural Series p aEo 310521-56 BUILDING DEPARTMENT RECEIVED il1M08/18/E- PORCOMIXANWINS 04/^ ^ ''' 1 IMP Venting Configuration ASF'1IV BUILC ING DEPARTMENT Surface mount power vent Riser required Flat roof configuration (min. 12"high.Check local codes). I I surface mount Bottom Peaked roof power vent configuration Intake Models 36"Min. clearance from — outlet surface mount Direction of ' exhaust flow power vent 2 Direction of air flow 36"Min. clearance < from Air intakes \ J \ intake ~ > H Direction of air flow Maximum flue outlet pipe length is 150 feet plus 6 elbows and the maximum combustion air inlet pipe is 150 feet plus 6 elbows. Figure 11: Venting configurations for bottom intake models. Venting plenum NOTE: Plenum must not be shared with other appliances. Some installations - particularly in new renovations or with pre-existing constraints / obstacles may require the construction of a plenum in order to accommodate multiple air intakes. The plenum must be made of furnace ducting (Minimum 26 gauge) or other material impervious to moisture. The constructed plenum must have a minimum cross-section of 150in2 and be sealed to the air-intake collars on the appliance. The plenum may be transitioned to a single intake as long as the recommended cross-section is maintained. For a single air intake, the rule of a maximum of 150 feet plus 6 elbows still applies. RECEIVED 04/05/ 22 Low 310521-56 Architectural Series 17 100005181 y&Rod N1 s Nir ASPEN BUILDING DEPARTMENT RECEIVED aliFEWirl FORM 04/05/2022VAMINCE imp ASPEN Surface mount power vent BUILC ING DEPARTMENT Riser required (Flat roof configuration , J I v.— (Min. 12"high.Check local codes). Surface mount Top Peaked roof power vent configuration Intake Models 36"Min. clearance from — outlet r , [I '''‘ i 2 > z Surface mount 36"Min. power vent U) Direction of air flow clearance 8 _ — — _ from intake Q to outlet - = I Maximum flue outlet pipe length is 150 feet plus 6 elbows. Maximum combustion air inlet pipe is 150 feet plus 6 elbows. J Figure 12: Venting configurations for Top Intake models. RECEIVED 04/05/2022 V TOWN&CONTRY 100005181 18 Architectural Series 310521-56 LUXURY FIREPLACES ASPEN BUILDING DEPARTMENT RECEIVED rib',- IMPAANCE 04/o:/LOLL `8/2022 FOICO ` Venting Specifications ASPEN Power vent mounted vertically BUIL1 ING DEPARTMENT with intake vents built into an elevated riser. <—n Bottom ' Intake 0 01-11 Models o � Intakes combined into a larger single Power vent mounted duct to reduce exterior penetrations. horizontally. All venting including exhaust is zero clearance to combustible materials. 12"exhaust venting can be a maximum of 150ft plus 6 elbows For servicing purposes,it is recommended that,if possible, the optional motorized dampers ri be accessible after installation. • Optional • • motorized Must use 7"intake venting lines. • dampers Each venting line can be a maximum of 150ft plus 6 elbows. • • I - Fresh air intakes can be joined into a larger single duct or plenum. I"I 0 T (Minimum 150 in2 cross-section for all models) — — 0 T Air intake vents ♦ J \ I Figure 13: Venting specifications for Bottom Intake models. • Bottom Air intake venting uses three 7" standard single wall furnace grade venting ducts on 3-6ft burner models, and four 7" vents on 7-8ft models. All vent intakes must be used. Each intake line can be up to a maximum of 150 ft plus 6 elbows. • Motorized dampers are optional. • Exhaust venting uses 12" standard single wall furnace grade venting material. Maximum length is 150 ft plus 6 elbows. • All Venting is zero clearance. • All Vent seams (Intake and Exhaust) including elbow rivets must be sealed with highRVED aluminum tape. 04/05/g22 310521-56 Architectural Series 19 100005181 ;°Wp 8•, °; -cRs ASPEN BUILDING DEPARTMENT RECEIVED In(oaJL8/ z I 04/05/2022 ll Uroxtmotctr�NICE ASPEN BUILD NG DEPARTMENT Power vent mounted vertically ( with intake vents built into an elevated riser. Top P-7—> Intake l 01 '_❑ I Models 11 ❑ Intake ss c omnb ine td tion troe da uce exterior penetrations. Optional All venting including exhaust is motorized Power vent mounted zero clearance to combustible dampers horizontally. materials. 12"exhaust venting can be a maximum of 150ft plus 6 elbows. For servicing purposes,it is ❑ recommended that,if possible, the optional motorized dampers Air intake vents be accessible after installation. — ❑ Must use 10 inch intake venting lines.Each venting line can be a maximum of 150ft plus 6 elbows. Fresh air intakes can be joined into a larger single duct or plenum. (Minimum 150 in2 cross-section for all models) --- --- Figure 14: Venting specifications for Top Intake models. • Top Air intake venting uses two 10" standard single wall furnace grade venting ducts on all models. Both lines must be used. Each intake line can be up to a maximum of 150 ft plus 6 elbows. • Motorized dampers are optional. • Exhaust venting uses 12" standard single wall furnace grade venting material. Maximum length is 150 ft plus 6 elbows. • All Venting is zero clearance. �.., • All Vent seams (Intake and Exhaust) including elbow rivets must be sealed with high tOrnpeiEN aluminum tape. 04/05/2022 r TOWN&cop TRs 100005181 20 Architectural Series 310521-56 p aE ASPEN BUILDING DEPARTMENT RECEIVED kes-viilliENE.4), 04/up/Luce Air Intake ASPEN „ BUILE ING DEPARTMENT ' 7 J 1 7 Inch Intake Hood 6 3/4" Dimensions 1 1/8" 1l1/8" ir1 T 3 1/2" ir 8 3/8" 9 3/8" Top 9 3/8" 1 " 1 7/8" -0E-1 7/8" w" �`� 10 3/4" °ter° °ter° 10 3/4" 6 3/4' 110.- 7" T : i -3 1/2"� 1 7/8" 614,, f17/8" REAR SIDE Figure 15: 7 inch intake vent dimensions. RECEIVED 04/05/022 310521-56 Architectural Series 21 100005181 TOWLUXUN&F COUNTRY ASPEN BUILDING DEPARTMENT RECEIVED frrn Foricoutcumma 04/05/2022 ASPEN BUILC ING DEPARTMEN' 10111.-- J 10 Inch Intake Hood Dimensions 6 3/4" 1 1/8" 1l1/8" 1 1 3 1/2" 11 3/8"-110- 12 3/8"-1.- TOP 12 3/8"-11.-- 1„ 1 7/8" f1 7/8" 0 13 3/4" 22 IIi:Ii %! °�° 13 3/4" 6 3/4"-110- 10" 1 7/8" 778,, —1 7/8" REAR SIDE Figure 16: 10 inch intake vent dimensions. RECEIVED 04/05/2022 r rowNacop:rc ` 100005181 22 Architectural Series 310521-56 p , aE ASPEN BUILDING DEPARTMENT RECEIVED II O4/ V3/LVLL � Optional Motorized Damper ASPEN BUILDING DEPARTMENT jol! ti 114.1 Figure 17: Optional motorized damper. The optional motorized damper closes off air from the outside being able to enter the fireplace when the fireplace is off. This unit is mounted near the air intake vent. This unit is wired directly to the fireplace body (Figure 54 on page 38). One motorized damper is required for each of the air intake venting lines. All bottom intake models use 7 inch motorized dampers if required for installation. All top intake models use 10 inch motorized dampers if required for installation. 15 1 11"_11... 4 5/8 4 5/8" 5 1/4" 8" 7 1/4" = 91/2 I rki12" l f1/2" 7 �„ 10' 110.- Figure 18: 7 inch Motorized damper dimensions. Figure 19: 10 inch Motorized damper RECEIVED 04/05/ 22 310521-56 Architectural Series 23 100005181 TOWLUXUN&pop NTR= ASPEN BUILDING DEPARTMENT RECEIVED /l muma O4/VJ/GVGG �"` ` Power Vent This section is an overview of the Power Vent Installations. Consult the specific BUILDOMAy iriLLlt Manual (included with each power vent) for up to date and detailled instructions. NOTE: The installer must supply; • An approved 14ga. household power wire from the fireplace to the Power Vent, for the 120VAC power. and, • A minimum 18ga, 2 conductor (bell/alarm) wire from the fireplace to the power vent for the 24VAC Blower Control. Electrical Motor specifications: 115 VAC Single phase, 60 Hz 1/2 HP 6.8 Amps Weight: Aprox. 30 lbs. -- r v. L_________a ii Figure 20: Power vent. Use the provided self-tapping screws to attach the Use the provided lag screws to attach the power vent vent pipe to both sides of the anti-vibration collar. to the site constructed riser or curb. There are 8 holes around the base. (Two per side). 04/05/2022 r TOWN&copNTRv 100005181 24 Architectural Series 310521-56 p .E ,. E= ASPEN BUILDING DEPARTMENT RECEIVED alilleOfig-1 18/18/20224 FORCOOkallalANCE 04/8.J/2822 Power Vent Dimensions I - 1 I I • • I i. - • • . , 19- i 1 -• i - - - 231 „ . CO] . 221" 0 IT -... .. _ A 1-01.. .1- U. _ ____ D 4 ..-11 i . . . ... I 3-8 1_ • • 1. 1 „ 23-4 •-- Figure 21: Power vent dimensions. Vertical Installation ...., .„.. 44 P 4 I. 4 IIIP. 4110 --".. ''... ..." ,-. ,-..- 23" 12 1/2" 12 1/2" M n. 23" -' - .--- „_ .---- ,• Site Fabricated Riser .-- .--- Max 22 1/2" .-.--- ._,„.„ Max 22 1/2" .---* Figure 22: Power vent installation. RECEIVED 04/05/022 310521-56 Architectural Series 25 100005181 TOWN&COUNTRY ASPEN BUILDING DEPARTMENT RECEIVED riliEWirl 04/e3/2822 Horizontal Installation Max 22 1/2" 2 1/2" 12 1/2" Min Site Fabricated �r Mounting Curb iI 23 II 0. 12 1/2" Min. al Max 22 1/2" 23" 111. Figure 23: Power vent horizontal installation. When installing the power vent horizontally, ensure the side of the power vent with the attached electrical junction box is facing downwards. Use exterior silicone/caulk around the base of the power vent to seal it to the building envelope. Any horizontal run leading to the power vent shall be sloped down to the outside at a minimum of 1/4 inch per foot of vent length. RECEIVED 04/05/2022 V TOaCOUNV 310521-56 100005181 26 Architectural Series �VXupYWN . aE .TR�E, ASPEN BUILDING DEPARTMENT RECEIVES illafrl 08/18/2022 04/ un/LULL Vent Terminal Clearance ASPEN BUILDING DEPARTMENT Note: Minimum 3 feet clearance from solid objects/walls or between multiple power vents. . 411-441110 Figure 24: Power vent clearances. Power Vent Wiring $ik Black Weather proof Conduit White to Blower Motor and Control r p p I• C)�! pi_ Ground a a 120V Power and 24 V Blower Control from 0 a o Red Fireplace(Wire not provided with unit) Grey Figure 25: T.S. Wiring diagram. RECEIVED 04/05/022 310521-56 Architectural Series 27 100005181 TOWLUXUN&F COUNTRY ASPEN BUILDING DEPARTMENT RECEIVED rillafr18/2022 l 04 v jz.vz.z. sh Mount Power Vent Dimensions ASPEN BUILD-RCDEP1RTMENT 261/8" CC ) ( ) ( ) ] I I 28" 1 1/2" BRICK LEDGE 28" 14 3//8" - ► A \ . o o X A A 1 zI`1 . . 1 I L A I 1 ' I ! s 1 `1 \/ \/ 1 I, 1 I el 1 1 1 b ao N. NCo- Co- 1 1 1 I coNL ! H. ` I >1 N 1 /\ /\ 1 ` 1 ► 1 J 1 . - . 1 H c 1 1 1 /: � \ V 1 30" Figure 26: Architectural series power vent dimensions. RECEIVED 04/05/2022 r ro T„,, NTRv 100005181 28 Architectural Series V% . aE . E, 310521-56 BUILDING DEPARTMENT RECEIVE piii t n O4/ VJ/LVLL -" Waming the Flush Mount Power Vent ASPEN BUILDING DEPtR4 ommended framing. See local building codes for more information. [69mm] 27"[69mm] r �� 1 cLIIIIill Figure 27: PV Framing Dimensions. Figure 28: Fan -witho EICEIVED installed. ��`` 04/05/022 310521-56 Architectural Series 29 100005181 TOWN aF COUNTRY ASPEN BUILDING DEPARTMENT RECEIVED tesYillOrg— 04/ Vr/ LULL Mush Mount Electrical Connection ASPEN BUILDING DEPARTMENT $i 4 White Black 120V Power from I Fireplace (Wire not provided with unit) Ground Grey ii P,T Red F _„„...... 24 V Blower Control from Fireplace (Wire not provided with unit) Figure 29: FMPV Wiring Diagram. RECEIVED 04/05/2022 o lmi„, OUNTRV 100005181 30 Architectural Series 310521-56 �VXup . aE .�E, ASPEN BUILDING DEPARTMENT RECEIVED -RIV D 18/2022 O4/VJ/LVLL sw `` mte Baffle Adjustment ASPEN BUILDING DEPARTMENT 4 li11( a 1riiilil 1 . 4* ` - 1,Ilk; al i ' ® Figure 30: Adjustable baffle ports. Figure 31: Adjustment accessible through the baffle cover. The air baffle (Figure 30) is set to fully open before it is shipped and might need adjustment. However, if adjustment is required, the sliding plates can be moved by inserting a screwdriver or other object up through the baffle cover (Figure 31). There is a bracket on either end of the baffle to use for easy adjustment. If the flame pattern is too hectic, close the baffle opening a half inch at a time and monitor the flame with all glass panes installed. NOTE: The more you close the baffle, the more the outer glass temperature will rise, as less heat is being evacuated from the combustion zone. The baffle cover is secured by six bolts (Figure 31). If removal of the baffle cover is necessary, always remove the two center bolts last, as well as installing them first when re-installing the baffle cover. RECEIVED 04/05/ 22 310521-56 Architectural Series 31 100005181 ,=y8.F a°;! -cRsNir ASPEN BUILDING DEPARTMENT RECEIVEDEViliEWirl o4/e3/2ezz `` 'ift Black Glass Option Installation ASPEN - BUILDING DEPART ► . • . 1 1'1 1 1 1 1 1 i 1 I r I'i 1 I ♦o si RLN ,1 1 Iwo w'svw I i I 1 I I ( i 11%v M:ItEw 1 1 1 1 4 1 1 1 , , r u se Rnw II' i!4!'4 I I I I I 1 / 1 • 1 \11,i!..... , i ,', , 1'/ 1 1 1'K ter 11CI , — • a Figure 32: Single sided firebox before black glass installation. Note: Installation of the rear black glass plate is a two person job. 1. Using the supplied suction cups, insert the top edge of the rear black glass plate into its slot located on the ceiling of the unit (Figure 33). • 'Alb 4401 .( , Pill) . • • Aiiii RECEIVED Figure 33: Insert top end of rear black glass plate first. 04/05/2022 V I?X O1;)= 100005181 32 Architectural Series 310521-56 VXupV. ASPEN BUILDING DEPARTMENT RECEIVED 3oa;12o 2I 8/fericookarinvia 04/05/2022 ASPEN 1 BUILDING DEPARTMENT I • • Figure 34: Lift bottom end of black glass over the rear mesh screen. 2. With the top edge of the plate lifted into its slot, maneuver the bottom edge of the plate over top of the mesh tray and lower the plate down into its slot (Figure 34). 3. Insert the top edge of the left hand black glass sheet into its slot located in the ceiling of the unit (Figure 36). 111 k --.'14111illirli -- ---- -____ i \'row. • .o '1 Milli 0 ___ Figure 35: Rear black glass plate in place. Figure 36: Insert top of side black glass first., EIVED 04/05/0,22 310521-56 Architectural Series 33 100005181 TOWN&COUNTRY ASPEN BUILDING DEPARTMENT RECEIVED II 0 4/ 0 I mP - PEN- .,i G DEPARTME�f I — _ I I• iiii 0 .I N\, * /.. • '' N • • % . T Figure 37: Insert bottom end of side black glass plate. Figure 38: Insert opposite black glass plate. 4. With the top edge of the side plate lifted into its slot, maneuver the bottom edge of the plate over top of the pilot assembly and over the mesh tray and lower the plate down into its slot (Figure 37). 5. Repeat this procedure for installing a black glass plate for the right hand side (Figure 38). 6. Once all black glass plate are installed, fill the burner tray with crushed glass media. Glass Burner Media Installation 1VikWR 11.71:0"1 y,,,, T_ _ v • Figure 39: Twilight Diamond crushed glass media. Figure 40: Crushed glass media in burner tray. The amount of crushed glass media provided is dependent on the length of the unit. Four pounds are alloted for each foot length of the unit. Spread all of the crushed glass media in the burner tray. Cover all of the black mesh burner tray but do not cover the pilot assembly or the burner ports. RE(,11VED 04/05/2022 r TOWN&COUNTRY 100005181 34 Architectural Series 310521-56 p .E ASPEN BUILDING DEPARTMENT RECEIVEDrill-LEW) 04/v./LULL Front Glass Plates Installation Inftercplass Plate Installation Upper slot for Outer glass plate =s` ►, /. xr, --eff"' .„,----- ' 11\ :::;:;:; :::1- - . Gap7/ P Upper slot for Inner glass plate ql‘ _ Figure 41: Upper slots for front glass plates. Figure 42: Insertion point between furthest louver and lower inside slot. Note: The following procedure may be a two person job depending on the length of the inner glass plate. Because of working space constraints, the upper edge of the inner glass plate cannot be immedi- ately inserted into the upper inner slot (Figure 41) until the bottom edge of the glass plate has been lowered into the large gap between the furthest louver and the lower inner slot (Figure 42). Once the glass plate has been lowered into this gap the upper edge can then be lifted up into the upper inner slot. 1. There are 3 horizontal louvers at the bottom of the fireplace opening extending the length of the opening. The bottom edge of the inner glass plate will be inserted down into the gap behind the furthest louver (Figure 43). it. --:: ,. ,...: Fr: N . - . • • ...... .. oir. , _ . 1 ,..... , .:•;,., , . e ... , - . _ ,. „ . .„ . . i p -� • .�Figure 43: Lowering bottom edge of inner plate into gap. Figure 44: Raising top edge into the in r .:- ED 04/05/022 310521-56 Architectural Series 35 100005181 TOWLUXUN&•COUNTRY ASPEN BUILDING DEPARTMENT RECEIVES r1IEW1r18/2022) 04/05/2022 m' ASPEN BUILDING a411,117F _ 4 Figure 45: Lower the inside front plate into its slot. Figure 46: Inside securing plates. 2. Once the lower edge has been inserted into the gap, tilt the glass plate upward and into the upper inner slot (Figure 44). 3. With the upper edge of the glass plate inside the upper inner slot, tilt the glass plate toward the lower inner slot and lower the glass plate into this slot (Figure 45). 4. Install the inside securing plates (Figure 46) into the space between the inner and outer front glass plates. These securing plates are identical and have a flared edge which are installed so that the flared edges make contact with the inner glass sheet (Figure 47). These securing plates are held in place with magnets (Figure 48). • • Magnets • 4110 1(til • Flared edge - - toward inner glass plate Figure 47: Left side securing plate installation. Figure 48: Installing right side securing plate. 04/05/2022 r TOWN&coU NTRv 100005181 36 Architectural Series 310521 56 �V%u• . •E «E, ASPEN BUILDING DEPARTMENT RECEIVED llpiIl FoRcatLukuma 04/05/2022 m' AS Makesure 1;1 BUILDING I E .AR Liu EN 1 5. Make sure that the securing plates are pushed up against the inner glass plate (Figure securing 49). This will keep the inner glass plate from plate is vibrating pushed y W right up to -- the inside glass plate. This will keep any vibration to a minimum Figure 49: Position securing plate up against the inside glass plate. Outer Glass Plate Installation Note: The following procedure may be a two person job depending on the length of the outer glass plate. 1 . Using the supplied suction cups, fit the upper edge of the outside front glass plate into its slot (Figure 50). Angle the lower edge into a vertical position and lower the pane into the bottom slot (Figure 51). Do not remove the suction handles yet as this sheet is to be moved once more. 2. Once the inside front glass sheet is installed, shift it so that it is centered in its frame and so that there is a gap of about 1/8" between the glass sheet and each side of the frame. ......, 7 .... . de I MO 4 I rr • , . . . Q' iE �, Figure 50: Insert top end of outer glass sheet in first. Figure 51: Outer glass plate lowered into its slot. 04/05/022 310521-56 Architectural Series 37 100005181 Lowy&pOU NTR i ASPEN BUILDING DEPARTMENT RECEIVED rilENE-- 0.2022D OLVLL "�` ` 4/VJ/ Electrical Connection ASPEN BUILDING DEPARTMENT Power to this unit is 120VAC. The electrical ", connection boxes are located behind a removable ' " panel that runs the length of the lower side of the appliance. ` After the panel is removed, the electrical connection i Remove 4 Screws box cover can be removed to access the wiring _zei.,; (Figure 52). Once wiring is completed (Figure 55), power will be . t gimminAll supplied to both the power vent and the main unit control module (Figure 53). The optional motorized damper wiring is located behind the removable panel as well in the second Figure 52: Electrical connection panel removed. connection box (Figure 54). There will be a pair of wires for the appropriate number of dampers specified for the appliance. These wires are not polar specific. Low voltage wiring can be used for connecting the dampers. The CAT5e cable is located here as well. Connect the Cat5e cable to the control panel wall receptacle (Figure 56). Ensure the wiring strain relief clamps are snug and secure. Re-attach the box covers, followed by the compartment panel when all wiring is complete. Use aluminum tape to seal all seams of the compartment panel before attaching facing material. i • — I • To Power Vent !Iiiii- -ma � lk. f F �' To optional : 2 . h motorized Ilk 1 dampers /IP 7,4' To Unit MainPower Cat 5e cable ' I _ connects to!� �i Control Panel i,i: '-y Figure 53: Inside of electrical connection box. Figure 54: Motorized damper electrical connection' L ; 04/05/2022 r TowNacop eTR= 100005181 38 Architectural Series 310521-56 —""--- ASPEN ASPEN BUILDING DEPARTMENT RECEIVED ill O4/VJ/GVLL " ` Electrical Diagram ASPEN BUILDING DEPARTMENT To Unit Power Power Junction Box h Black From unit From House Black �W White Power Circuit Green White Green White White Green Blue Black To Power Vent Figure 55: Wiring at fireplace - power. 24V Junction Box To Damper Black Black Blue 'r From unit Controls Red To Blower Grey Control 111 Cat 5e cable To Control Panel Figure 56: Wiring at fireplace - Dampers and controls. REI PEIVED 04/05/g22 310521-56 Architectural Series 39 100005181 (=v8.,a°; cP ASPEN BUILDING DEPARTMENT RECEIVED EvIw lfinVIM 04/u.J/LULL .20224 �"` ` LED Strip Replacement ASPEN BUILDING DEPARTMENT •T. ..- 7 r- wi I- r f r r r r ;f r r Lillt ,..rc r r :r r rZi Figure 57: Individual LED section. There are two rows of LED lights in this fire feature, one row on each side of the burner. Each row of LED lights is made of individual LED sections which can be joined together using bridge connectors to achieve the desired row length (Figure 58). Each row of sections also has its own main electrical connector (Figure 59). s volv / *f0e/ /,' • :;. ,. ,, 1� I l /I/ .` / - • Figure 58: LED individual sections joined together. Figure 59: LED connector. Removing an LED section 1. To remove an individual LED section or sections, begin by disconnecting the main power to the fire feature at the main circuit breaker. Give time for the unit to cool down. 2. Remove the glass panels. 3. Remove the glass media and the relevant glass tray. 4. Disconnect the main electrical connection located on the left hand side of the fire feature by lifting the connector up as shown in. RECEIVED 04/05/2022 r TOWN&COUNTRY 100005181 40 Architectural Series 310521-56 p RELUXUY ,«E, ASPEN BUILDING DEPARTMENT RECEIVED ��� 04/C5/2022 -- - 1. BUILDIN 7EPARTMENT -_. .‘. ' • ir Ilr lir -1, r 1 lz 1 I I' 1 t 1 1 1 1: I r l.: I 1 I I 1 Figure 60: LED strip bridge connector. Figure 61: LED strip hold down tabs. 5. Remove the bridge connector of the LED section(s) to be replaced (Figure 60). These connector tabs lift up much like the main electrical connector. In this way, individual LED sections can be replaced without removing the entire row of LED sections from the fire feature. 6. The LED sections and rows are held in place by hold down tabs (Figure 61). These tabs can be lifted up so that the LED section can be removed. 7. When removing an individual LED section, lift up the side of the LED section next to the tabs that were just moved upwards and then remove the LED section (Figure 62). -ram • T _ _ r •y, . . . --r\> <4_1 • • Figure 62: LED strip removal. Figure 63: Arrows always meet. NOTE: When replacing an LED section, make sure that the arrows on the sections meet as shown in Figure 63. Whether joining full sized sections to other full sized sections, or when joining a full sized section to a short section, the arrows must meet each other. As you stand in front of the fire feature, the arrows will be located on the sides of the sections furthest away from you. 8. Reconnect the individual LED sections using a bridge connector as shown in (Figure 60). 9. Reconnect the main electrical connector as shown in (Figure 59). 10. Return the glass tray(s), glass media and glass panels to their original positions. RECEIVED 04/0 5 g22 310521-56 Architectural Series 41 100005181 OW&a°;acRs ASPEN BUILDING DEPARTMENT RECEIVED 1 �i08/1erg 04/VJ/LVLL ' Control Panel Installation ASPEN '3UILDING �easeNrefer to the instrutions included with your controls for installation. NOTE: The CAT5e cable has a maximum length of 50 feet and so the touch pad must be installed within this distance. NOTE: Make sure that the ON/OFF switch is in the ON position before mounting the touch pad in its frame. NOTE: Make sure that the AC power to this appliance is turned off before installing or servicing the touch pad. RECEIVED 04/05/2022 I9,=,,. TRV 100005181 42 Architectural Series 310521-56 ��.�... .E �.�E, ASPEN BUILDING DEPARTMENT RECEIVED i1aliIEME 04/uo/LOLL Gas Connection ASPEN BUILDING DEPARTMEN \ I . Ini prr Of, mwq- LI* �_- _ -' 44.1141iii, 4141 _ Figure 64: Gas connection point. Figure 65: Gas valve shut off. All units ship with a multi-capped half inch NPT pipe for gas connection (Figure 64). All units also ship with a gas valve shut-off (Figure 65). This shut-off handle is located on the right side of the glass door opening between the inner and outer glass panes. Push this handle down before installing the outer glass panes. Gas Pressure Requirements Natural Gas Liquid Propane Gas Gas pressure requirements Gas pressure requirements Input Pressure Natural Gas Input Pressure Liquid Propane Gas Minimum 5.0" IN/WC (1.24 kPa) Minimum 12.5" IN/WC (3.11 kPa) Maximum 7.0" IN/WC (1.74 kPa) Maximum 13.9" IN/WC (3.45 kPa) Manifold Pressure Manifold Pressure Maximum 3.5" IN/WC (0.87 kPa) Maximum 11.0" IN/WC (2.73 kPa) RECEIVED 04/05/g22 310521-56 Architectural Series 43 100005181 (=v8.,a°; cP ASPEN BUILDING DEPARTMENT RECEIVED EVENE-1 FORCOU `� O4/V�/LVLL Lighting Instructions ASPEN BUILDING DEPARTMENT FOR YOUR SAFETY READ BEFORE LIGHTING Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. BEFORE LIGHTING: smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: - Do not try to light any appliance. - Do not touch any electrical switch; do not use any phone in your building. - Immediately call your gas supplier from a neighbour's phone. Follow the supplier's instructions. - If you cannot reach your gas supplier, call the fire department. B. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance &to replace any part of the control system &any gas control which has been under water. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above this label. 2. Move switch to "ON" position (unit will purge for 10 seconds) 3. The appliance will try igniting 3 times. If the appliance fails to ignite, the control will lock out. 4. Call your service technician or retailer to rectify the issue. TO TURN OFF GAS APPLIANCE 1. Move switch to the "OFF" position (unit will post-purge for 15 seconds). 2. Turn off all electrical power to the appliance if service is to be performed or for extended shutdown. CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing,furniture, gasoline and other liquids having flammable vapours away. Keep burner and control compartments clean. See installation and operating instructions accompanying the appliance. ATTENTION: L'appareil est chaud lorsqu'il fonctionne. Ne pas toucher l'appareil. Risque de brulures graves. Serveiller les enfants. Garder les ventements, le meubles, ('essence ou autres liquides produisant des vapeurs inflammables loin de l'appareil.S'assurer que le bruleur et le compartiment des commandes sont propres.Voir les instructions d'installation et d'utilisation qui accompangnent l'appareil. RECEIVED 04/05/2022 r TOWN&cop ATR= 100005181 44 Architectural Series 310521-56 LUXURY FIREPLACES ASPEN BUILDING DEPARTMENT RECEIVED rillEWirl 08/18/2022 ARINICE O4/UJ/ LULL `` Maintenance C TJ N: BUILDING DEPARTMEN Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fire feature and its venting be inspected at least once a year by a qualified service person. GLASS PANEL: Warning: Do not operate fire feature with glass panel removed, cracked or broken. Replacement of the glass panel should be done by a licensed or qualified service person. Do not strike or otherwise impact the glass in anyway that may cause it to break. If the glass becomes cracked or broken it must be replaced before using the fire feature. Replacement glass can be obtained from your nearest Town & Country Fireplaces dealer. ANNUAL INSPECTION: a) Remove glass panel and inspect the Burner and Igniter for soot build up. If excessive build up of soot is present, have a qualified service person inspect and adjust the unit for proper combustion. b) Check that the venting pipe and venting terminal are open and free from blockage or debris. If the venting is disassembled for cleaning, it must be properly assembled and re-sealed. Refer to VENTING section for proper procedure. Note: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids. Periodically: a) Viewing glass may be cleaned as necessary with fireplace glass cleaner. CAUTION: Do not use abrasive cleaners on glass or any other part of the fire feature. Do not clean glass when hot. RECEIVED 04/05/g22 310521-56 Architectural Series 45 100005181 (=v8.,a°; cP ASPEN BUILDING DEPARTMENT RE EIVED II FeRcomamiiics O4/U0/ LULL Replaceable Parts ASPEN I UILDH FPJRoMEN ITEM DESCRIPTION 80001338 Switch Vacuum, .6" WC, Pellet /Architectural 80002698 Touch Screen Display, Control Ver. 1.5 B, Architectural 80002335 Burner Media, Non Reflective Glass, Ice, 4LB, Architectural 80002367 Valve assembly with transducer/ fittings, Architectural 80002368 Pressure transducer, Architectural 80002369 Ignition Module, Helifire /Architectural 80002370 Transformer 24 volt, Architectural 80002371 Transformer 12 volt, Architectural 80002372 LED board short, Architectural 80002373 LED board long, Architectural 80002374 Suction cup, Architectural 80002379 Toggle switch, Architectural RECEIVED 04/05/2022 r TOW N&coU eTR= 100005181 46 Architectural Series 310521-56 p aE ASPEN BUILDING DEPARTMENT RECEIVED /igo 08/18/2022 o471.7.27=511611621 Rating Label ASPEN BUILDING DEPARTMENT 04ERGy VENTED GAS FIREPLACE-NOT FOR USE WITH SOLID FUEL FOYER AU GAZ A EVACUATION-NE PAS UTILISER AVEC DU 723 COMBUSTIBLE SOLIDE C( —E)US THIS IS A DECORATIVE PRODUCT AND IS NOT INTENDED P.4.1-15 Efficiency:9.9% TO BE USED AS A HEATING APPLIANCE. This Appliance is Equipped For Use With I Cet Appareil est Equipe Pour Utilise Avec: TOWN&COUNTRY ANSI Z21.50/CSA 2.22(2016)Vented Decorative Gas Appliance. NATURAL GAS/ L.P.GAS/ FIREPLACES'" Certified for/Certifie pour Canada and U.S.A. DU GAZ NATUREL ■ DU GAZ L.P. MODEL/ ■ FOR USE WITH/ NATURAL.GAS/ L.P GAS/ MODELE: EN CASE D'EMPLOI AVEC: DU GAZ NATUREL DU GAZ L.P. 3FT ARCHITECTURAL Minimum supply pressure/Pression minimum d'alimentation: 5.0 in/wc/5.0 po/c.e. 12.5 in/wc/12.5 po/c.e. (For the purpose of input adjustment I dans le but de realer I'alimenation) (1.24 kPa) (3.11 kPa) SERIES Maximum supply pressure/Pression maximum d'alimentation: 7.0 in/wc/7.0 po/c.e. 13.9 in/wc/13.9 po/c.e. (1.74 kPa) (3.45 kPa) SERIES/ Manifold pressure/Pression de la tuyauterie: Maximum 3.50 in/wc/3.50 po/c.e. 11.0 in/wc/13.9 po/c.e. SERIE: A (0.87 kPa) (2.73 kPa) Orifice Size/Diametre de l'injectuer: NA X2 LA X2 MADE IN CANADA Input BTU/hr(kW)/Entree BTU/h(kW): Max.:48,000 (14.06) Max.:48,000 (14.06) FABRIQUE AU CANADA Blower electrical rating: 115v,60hz,5.9 A/Normes electriques du ventilateur: 115v,60hz,5.9 A This appliance equipped for altitudes 0-4500 ft.(0-1371.6 m)/Cet unite est congu pour des altitudes variant entre 0-4500 pieds(0-1371.6 m).In Canada,also certified for installation in a bedroom or a bedsitting room/Aussi certifie pour installation dans une chambre a toucher ou une salle de sejour.This appliance must be installed in accordance with local codes,if any;if none,follow the current CAN/CGA-B149(Canada),or ANSI Z223.1(USA)Installation Codes.Installer l'appareil selon les codes ou reglements locaux,ou,en('absence de tels reglements,selon les codes d'installation CAN/CGA-B149(Canada),or ANSI Z223.1 (USA)en vigeur. MANUFACTURED(MOBILE)HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,manufactured(mobile)home where not prohibited by local codes.See owners manual for details. FABRIQUEZ(MOBILE)MAISON: Cet appareil dolt etre utilise uniquement avec le type de gaz indique sur la plaque signaletique et peut etre installs dans une maison prefabriquee(mobile)installee a demeure si les reglements locaux le permettent.Voir la notice du proprietaire pour plus de details.Cet appareil ne peut etre converti a d'autres gaz sauf si une trousse de conversion certifiee est utilisee. Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH(in CANADA),and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR,Part 3280,or the current Standard for Fire Safety Criteria for Manufactured Home Installations,Sites,and Communities ANSI/NFPA 501A,(in the U.S.A.). Cet appareil diot etre installs conformement aux exigences de la norme CAN/CSA Z240 MH en vigueur de I'ACNOR,Installations de gaz dans les Constructions Mobiles. FOR USE WITH THE GLASS CERTIFIED WITH THE APPLIANCE ONLY/POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIEES AVEC L'APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES/CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Fireplace Products Ltd. Left and Right side are determined when facing the front of the appliance./Les cotes droit et gauche se determinent Duncan,British Columbia, en se mettant devant l'appareil et en lui faisant face. Top,Back and Side Standoffs/Sommet,Arriere et Cote Butee 0 in./0 po. (0 mm) Canada Sidewall to Appliance I Du mur lateral a l'appareil 0 in./0 po. (0 mm) Ceiling to Appliance/Plafond a('appareil 0 in./0 po. (0 mm) DATE OF MANUFACTURE Mantel to Appliance/Du manteau al'appareil 0 in./0 po. (0 mm) Maximum Mantel Extension/Allongement maximum du manteau 0 in./0 po. (0 mm) `See Installation Manual for more detail/Voyez des Directive de('Installation pour plus detaux. Mantel Supports/Supports du manteau 0 in./0 po. (0 mm) JAN FEB MAR APR 2018 Vent Pipe/Dechargez le Tuyau 0 in./0 po. (0 mm) • WARNING: Improper installation,adjustment,alteration,service or maintenance can cause injury or property damage.Refer MAY JUN JUL AUG 2019 to the owner's information manual provided with this appliance.For assistance or additional information,consult a qualified installer,service agency or the gas supplier. AVERTISSEMENT: Une installation,un reglage,une modification,une reparation ou un entretien mal effectue peut causer SEP OCT NOV DEC 2020 des dommages materiels ou des blessures.Voir la notice de l'utilisateur qui accompgne l'appareil.Pour de('aide ou des renseignements supplementaires,consultez un installateur,un technicien agree ou le fournisseur de gaz. 101218 568000065 3FT Architectural Series RECEIVED 04/05/ 22 310521-56 Architectural Series 47 100005181 TOWN&COUNTRLUXUY ASPEN BUILDING DEPARTMENT RECEIVED13 L Ir-_ ,Lti os/is/2o22 J 04/05/2022 ASPEN BUILDING DEPARTMENT 04ERGj_ VENTED GAS FIREPLACE-NOT FOR USE WITH SOLID FUEL FOYER AU GAZ A EVACUATION-NE PAS UTILISER AVEC DU 724 COMBUSTIBLE SOLIDE C LC US THIS IS A DECORATIVE PRODUCT AND IS NOT INTENDED P.4.1-15 Efficiency:11.4% 1 i 1 j y 1‘C TO BE USED AS A HEATING APPLIANCE. This Appliance is Equipped For Use With I Cet Appareil est Equipe Pour Utilise Avec: TOWN&COUNTRY ANSI Z21.50/CSA 2.22(2016)Vented Decorative Gas Appliance. NATURAL GAS/ M L.P.GAS/ FIREPLACES" Certified for/Certifie pour Canada and U.S.A. DU GAZ NATUREL DU GAZ L.P. MODEL/ ■ FOR USE WITH/ NATURAL.GASI L.P GAS/ MODELE: EN CASE D'EMPLOI AVEC: DU GAZ NATUREL DU GAZ L.P. 4FT ARCHITECTURAL Minimum supply pressure/Pression minimum d'alimentation: 5.0 in/wc/5.0 po/c.e. 12.5 in/wc/12.5 po/c.e. (For the purpose of input adjustment/dans le but de regler I'alimenation) (1.24 kPa) (3.11 kPa) SERIES Maximum supply pressure/Pression maximum d'alimentation: 7.0 in/wc/7.0 po/c.e. 13.9 in/wc/13.9 po/c.e. (1.74 kPa) (3.45 kPa) SERIES/ A Manifold pressure I Pression de la tuyauterie: Maximum 3.50 in/wc/3.50 po/c.e. 11.0 in/wc/13.9 po/c.e. (0.87 kPa) (2.73 kPa) SERIF: Orifice Size/Diametre de l'injectuer: _ NB X2 LB X2 MADE IN CANADA Input BTU/hr(kW)/Entree BTU/h(kW): Max.:64,000 (18.75) Max.:64,000 (18.75) FABRIQUE AU CANADA Blower electrical rating: 115v,60hz,5.9 A/Normes electriques du ventilateur: 115v,60hz,5.9 A This appliance equipped for altitudes 0-4500 ft.(0-1371.6 m)/Cet unite est conyu pour des altitudes variant entre 0-4500 pieds(0-1371.6 m).In Canada,also certified for installation in a bedroom or a bedsitting room/Aussi certifie pour installation dans une chambre a toucher ou une salle de sejour.This appliance must be installed in accordance with local codes,if any;if none,follow the current CAN/CGA-B149(Canada),or ANSI Z223.1(USA)Installation Codes.Installer l'appareil salon les codes ou reglements locaux,ou,en l'absence de tels reglements,selon les codes d'installation CAN/CGA-B149(Canada),or ANSI Z223.1 (USA)en vigeur. MANUFACTURED(MOBILE)HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,manufactured(mobile)home where not prohibited by local codes.See owners manual for details. FABRIQUEZ(MOBILE)MAISON: Cat appareil dolt etre utilise uniquement avec le type de gaz indique sur la plaque signaletique et peut etre installs dans une maison prefabriquee(mobile)installee a demeure si les reglements locaux le permettent.Voir la notice du proprietaire pour plus de details.Cet appareil ne peut etre converti a d'autres gaz sauf si une trousse de conversion certifiee est utilisee. Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH(in CANADA),and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR,Part 3280,or the current Standard for Fire Safety Criteria for Manufactured Home Installations,Sites,and Communities ANSI/NFPA 501A,(in the U.S.A.). Cet appareil diot etre installs conformement aux exigences de la norme CAN/CSA Z240 MH en vigueur de I'ACNOR,Installations de gaz dans les Constructions Mobiles. FOR USE WITH THE GLASS CERTIFIED WITH THE APPLIANCE ONLY/POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIEES AVEC L'APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES/CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Fireplace Products Ltd. Left and Right side are determined when facing the front of the appliance./Les cotes droit et gauche se determinant Duncan,British Columbia,en se mettant devant l'appareil et en lui faisant face. Top,Back and Side Standoffs/Sommet,Arriere et Cote Butee 0 in./0 po. (0 mm) Canada Sidewall to Appliance/Du mur lateral a('appareil 0 in./0 po. (0 mm) Ceiling to Appliance/Plafond a l'appareil 0 in./0 po. (0 mm) Mantel to Appliance/Du manteau al'appareil 0 in./0 po. (0 mm) DATE OF MANUFACTURE Maximum Mantel Extension/Allongement maximum du manteau 0 in./0 po. (0 mm) *See Installation Manual for more detail/Voyez des Directive de('Installation pour plus detaux. Mantel Supports/Supports du manteau 0 in./0 po. (0 mm) JAN FEB MAR APR 2018 Vent Pipe/Dechargez le Tuyau 0 in./0 po. (0 mm) WARNING: Improper installation,adjustment,alteration,service or maintenance can cause injury or property damage.Refer MAY JUN JUL AUG 2019 to the owner's information manual provided with this appliance.For assistance or additional information,consult a qualified installer,service agency or the gas supplier. AVERTISSEMENT: Une installation,un reglage,une modification,une reparation ou un entretien mal effectue peut causer SEP OCT NOV DEC 2020 des dommages materiels ou des blessures.Voir la notice de l'utilisateur qui accompgne l'appareil.Pour de('aide ou des renseignements supplementaires,consultez un installateur,un technician agree ou le fournisseur de gaz. 101218 568000066 4FT Architectural Series RECEIVED 04/05/2022 r TOWNaCOp COUNTRY 100005181 48 Architectural Series 310521-56 LUXURY FIREPLACES ASPEN BUILDING DEPARTMENT RECEIVED IALAih1Lfl 08/ie/2022 J FoRcoutcummte 04/05/2022 ASPEN BUILDING DEPARTMENT vF:R(; VENTED GAS FIREPLACE- NOT FOR USE WITH SOLID FUEL j FOYER AU GAZ A EVACUATION- NE PAS UTILISER AVEC DU 725 COMBUSTIBLE SOLIDE C(LC)us THIS IS A DECORATIVE PRODUCT AND IS NOT INTENDED P.4.1-15 Efficiency:12.8% //Itl►�`.\7) TO BE USED AS A HEATING APPLIANCE. This Appliance is Equipped For Use With / Cet Apparel!est Equipe Pour Utilise Avec: TOWN&COUNTRY ANSI Z21.50/CSA 2.22(2016)Vented Decorative Gas Appliance. NATURAL GAS/ M L.P.GAS/ FIREPLACES- Certified for/Certifie pour Canada and U.S.A. DU GAZ NATUREL DU GAZ L.P. MODEL/ ■ FOR USE WITH/ NATURAL.GAS/ L.P GAS/ MODELE: EN CASE D'EMPLOI AVEC: DU GAZ NATUREL DU GAZ L.P. 5FT ARCHITECTURAL Minimum supply pressure/Pression minimum d'alimentation: 5.0 in/wc/5.0 po/c.e. 12.5 in/wc/12.5 po/c.e. (For the purpose of input adjustment/dans le but de ropier I'alimenation) (1.24 kPa) (3.11 kPa) SERIES Maximum supply pressure/Pression maximum d'alimentation: 7.0 in/wc/7.0 po/c.e. 13.9 in/wc/13.9 po/c.e. (1.74 kPa) (3.45 kPa) SERIES/ Manifold pressure/Pression de la tuyauterie: Maximum 3.50 in/wc/3.50 po/c.e. 11.0 in/wc/13.9 po/c.e. SERIE: A (0.87 kPa) (2.73 kPa) Orifice Size/Diametre de l'injectuer: NA X2&NB X1 LA X2&LB X1 MADE IN CANADA Input BTU/hr(kW)/Entree BTU/h(kW): Max.:80,000 (23.44) Max.:80,000 (23.44) FABRIQUE AU CANADA Blower electrical rating: 115v,60hz,5.9 A/Normes electriques du ventilateur: 115v,60hz,5.9 A This appliance equipped for altitudes 0-4500 ft.(0-1371.6 m)/Cet unite est congu pour des altitudes variant entre 0-4500 pieds(0-1371.6 m).In Canada,also certified for installation in a bedroom or a bedsitting room/Aussi certifie pour installation dans une chambre a toucher ou une salle de sejour.This appliance must be installed in accordance with local codes,if any;if none,follow the current CAN/CGA-B149(Canada),or ANSI Z223.1(USA)Installation Codes.Installer l'appareil selon les codes ou reglements locaux,ou,en('absence de tels reglements,selon les codes d'installation CAN/CGA-B149(Canada),or ANSI Z223.1 (USA)en vigeur. MANUFACTURED(MOBILE)HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,manufactured(mobile)home where not prohibited by local codes.See owners manual for details. FABRIQUEZ(MOBILE)MAISON: Cet appareil doit etre utilise uniquement avec le type de gaz indique sur la plaque signaletique et peut etre installs dans une maison prefabriquee(mobile)installee a demeure si les reglements locaux le permettent.Voir la notice du proprietaire pour plus de details.Cet appareil ne peut etre converti a d'autres gaz sauf si une trousse de conversion certifiee est utilisee. Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH(in CANADA),and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR,Part 3280,or the current Standard for Fire Safety Criteria for Manufactured Home Installations,Sites,and Communities ANSI/NFPA 501A,(in the U.S.A.). Cet appareil diot etre installs conformement aux exigences de la norme CAN/CSA Z240 MH en vigueur de I'ACNOR,Installations de gaz dans les Constructions Mobiles. FOR USE WITH THE GLASS CERTIFIED WITH THE APPLIANCE ONLY/POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIEES AVEC L'APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES/CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Fireplace Products Ltd. Left and Right side are determined when facing the front of the appliance./Les cotes droit et gauche se determinent Duncan,British Columbia, en se mettant devant l'appareil et en lui faisant face. Top,Back and Side Standoffs/Sommet,Arriere et Cote Butee 0 in./0 po. (0 mm) Canada Sidewall to Appliance/Du mur lateral a l'appareil 0 in./0 po. (0 mm) Ceiling to Appliance/Plafond a l'appareil 0 in./0 po. (0 mm) DATE OF MANUFACTURE Mantel to Appliance/Du manteau al'appareil 0 in./0 po. (0 mm) Maximum Mantel Extension/Allongement maximum du manteau 0 in./0 po. (0 mm) *See Installation Manual for more detail/Voyez des Directive de('Installation pour plus detaux. Mantel Supports/Supports du manteau 0 in./0 po. (0 mm) JAN FEB MAR APR 2018 Vent Pipe/Dechargez le Tuyau 0 in./0 po. (0 mm) WARNING: Improper installation,adjustment,alteration,service or maintenance can cause injury or property damage.Refer MAY JUN JUL AUG 2019 to the owner's information manual provided with this appliance.For assistance or additional information,consult a qualified • installer,service agency or the gas supplier. AVERTISSEMENT: Une installation,un reglage,une modification,une reparation ou un entretien mal effectue peut causer SEP OCT NOV DEC 2020 des dommages materiels ou des blessures.Voir la notice de I'utilisateur qui accompgne l'appareil.Pour de('aide ou des renseignements supplementaires,consultez un installateur,un technicien agree ou le fournisseur de gaz. 101218 568000067 5FT Architectural Series RECEIVED 04/05/ 22 310521-56 Architectural Series 49 100005181 TOWN&COUNTRY NIII LUXUASPEN BUILDING DEPARTMENT RECEIVED IA LAih1Lfl 08/ie/2022 J FoRcoutcummte iiIIIP ASPEN BUILDING DEPARTMENT ;.1ER(;) VENTED GAS FIREPLACE-NOT FOR USE WITH SOLID FUEL FOYER AU GAZ A EVACUATION-NE PAS UTILISER AVEC DU 726 er COMBUSTIBLE SOLIDE CLC US THIS IS A DECORATIVE PRODUCT AND IS NOT INTENDED P.4.1-15 Efficiency:14.3% j?•?21tiV9 TO BE USED AS A HEATING APPLIANCE. This Appliance is Equipped pp q pped For Use With I Cet Apparel!est Equipe Pour Utilise Avec: TOWN&COUNTRY ANSI Z21.50/CSA 2.22(2016)Vented Decorative Gas Appliance. Certified for/Certifie pour Canada and U.S.A. NATURAL GAS/ ■ L.P.GAS/ FIREPLACES— DU GAZ NATUREL DU GAZ L.P. MODEL/ ■ FOR USE WITH/ NATURAL.GAS/ L.P GAS/ MODELS: EN CASE D'EMPLOI AVEC: DU GAZ NATUREL DU GAZ L.P. 6FT ARCHITECTURAL Minimum supply pressure/Pression minimum d'alimentation: 5.0 in/wc/5.0 po/c.e. 12.5 in/wc/12.5 po/c.e. (For the purpose of input adjustment I dans le but de ropier I'alimenation) (1.24 kPa) (3.11 kPa) SERIES Maximum supply pressure/Pression maximum d'alimentation: 7.0 in/wc/7.0 po/c.e. 13.9 in/wc/13.9 po/c.e. (1.74 kPa) (3.45 kPa) SERIES/ A Manifold pressure/Pression de la tuyauterie: Maximum 3.50 in/wc/3.50 po/c.e. 11.0 in/wc/13.9 po/c.e. SERIE: (0.87 kPa) (2.73 kPa) Orifice Size/Diametre de I'injectuer: NB X3 LB X3 MADE IN CANADA Input BTU/hr(kW)/Entree BTU/h(kW): Max.:96,000 (28.13) Max.:96,000 (28.13) FABRIQUE AU CANADA Blower electrical rating: 115v,60hz,5.9 A/Normes electriques du ventilateur: 115v,60hz,5.9 A This appliance equipped for altitudes 0-4500 ft.(0-1371.6 m)/Cet unite est conyu pour des altitudes variant entre 0-4500 pieds(0-1371.6 m).In Canada,also certified for installation in a bedroom or a bedsitting room/Aussi certifie pour installation dans une chambre a toucher ou une salle de sejour.This appliance must be installed in accordance with local codes,if any;if none,follow the current CAN/CGA-B149(Canada),or ANSI Z223.1(USA)Installation Codes.Installer l'appareil selon les codes ou reglements locaux,ou,en('absence de tels reglements,selon les codes d'installation CAN/CGA-B149(Canada),or ANSI Z223.1 (USA)en vigeur. MANUFACTURED(MOBILE)HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,manufactured(mobile)home where not prohibited by local codes.See owners manual for details. FABRIQUEZ(MOBILE)MAISON: Cet appareil dolt etre utilise uniquement avec le type de gaz indique sur la plaque signaletique et peut titre installs dans une maison prefabriquee(mobile)installee a demeure si les reglements locaux le permettent.Voir la notice du proprietaire pour plus de details.Cet appareil ne peut etre converti a d'autres gaz sauf si une trousse de conversion certifiee est utilisee. Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH(in CANADA),and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR,Part 3280,or the current Standard for Fire Safety Criteria for Manufactured Home Installations,Sites,and Communities ANSI/NFPA 501A,(in the U.S.A.). Cet appareil diot titre installs conformement aux exigences de la norme CAN/CSA Z240 MH en vigueur de I'ACNOR,Installations de gaz dans les Constructions Mobiles. FOR USE WITH THE GLASS CERTIFIED WITH THE APPLIANCE ONLY/POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIEES AVEC L'APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES/CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Fireplace Products Ltd. Left and Right side are determined when facing the front of the appliance./Les cotes droit et gauche se determinent Duncan,British Columbia, en se mettant devant l'appareil et en lui faisant face. Top,Back and Side Standoffs/Sommet,Arriere et Cote Butee 0 in./0 po. (0 mm) Canada Sidewall to Appliance/Du mur lateral a('appareil 0 in./0 po. (0 mm) Ceiling to Appliance/Plafond a l'appareil 0 in./0 po. (0 mm) DATE OF MANUFACTURE Mantel to Appliance/Du manteau al'appareil 0 in./0 po. (0 mm) Maximum Mantel Extension/Allongement maximum du manteau 0 in./0 po. (0 mm) *See Installation Manual for more detail/Voyez des Directive de('Installation pour plus detaux. Mantel Supports/Supports du manteau 0 in./0 po. (0 mm) JAN FEB MAR APR 2018 Vent Pipe/Dechargez le Tuyau 0 in./0 po. (0 mm) WARNING: Improper installation,adjustment,alteration,service or maintenance can cause injury or property damage.Refer MAY JUN JUL AUG 2019 to the owner's information manual provided with this appliance.For assistance or additional information,consult a qualified installer,service agency or the gas supplier. AVERTISSEMENT: Une installation,un reglage,une modification,une reparation ou un entretien mal effectue peut causer SEP OCT NOV DEC 2020 des dommages materiels ou des blessures.Voir la notice de l'utilisateur qui accompgne l'appareil.Pour de('aide ou des renseignements supplementaires,consultez un installateur,un technicien agree ou le fournisseur de gaz. 101218 568000068 6FT Architectural Series RECEIVED 04/05/2022 r TOWN&COp ATR= 100005181 50 Architectural Series 310521-56 LUXURY FIREPLACES ASPEN BUILDING DEPARTMENT RECEIVED IA LA ih,1 E oe/ia/2o22 J FoRcoutcummte liMP ASPEN BUILDING DEPARTMENT ��l_RC,) VENTED GAS FIREPLACE-NOT FOR USE WITH SOLID FUEL 727 FOYER AU GAZ A EVACUATION-NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE C �� P.4.1-15 Efficiency:15.7% US THIS IS A DECORATIVE PRODUCT AND IS NOT INTENDED f k121rA��� TO BE USED AS A HEATING APPLIANCE. This Appliance is Equipped For Use With / Cet Appareil est Equipe Pour Utilise Avec: TOWN&COUNTRY ANSI Z21.50/CSA 2.22(2016)Vented Decorative Gas Appliance. NATURAL GAS/ ■ L.P.GAS/ FIREPLACES" Certified for/Certifie pour Canada and U.S.A. DU GAZ NATUREL DU GAZ L.P. MODEL/ ■ FOR USE WITH/ NATURAL.GAS/ L.P GAS/ MODELE: EN CASE D'EMPLOI AVEC: DU GAZ NATUREL DU GAZ L.P. 7FT ARCHITECTURAL Minimum supply pressure/Pression minimum d'alimentation: 5.0 in/wc/5.0 po/c.e. 12.5 in/wc/12.5 po/c.e. (For the purpose of input adjustment/dans le but de regler I'alimenation) (1.24 kPa) (3.11 kPa) SERIES Maximum supply pressure/Pression maximum d'alimentation: 7.0 in/wc/7.0 po/c.e. 13.9 in/wc/13.9 po/c.e. (1.74 kPa) (3.45 kPa) SERIES/ Manifold pressure I Pression de la tuyauterie: Maximum 3.50 in/wc/3.50 po/c.e. 11.0 in/wc/13.9 po/c.e. SERIE: A (0.87 kPa) (2.73 kPa) Orifice Size/Diametre de I'injectuer: NA X2&NB X2 LA X2&LB X2 MADE IN CANADA Input BTU/hr(kW)I Entree BTU/h(kW): Max.:112,000 (32.82) Max.:112,000 (32.82) FABRIQUE AU CANADA Blower electrical rating: 115v,60hz,5.9 A/Normes electriques du ventilateur: 115v,60hz,5.9 A This appliance equipped for altitudes 0-4500 ft.(0-1371.6 m)/Cet unite est congu pour des altitudes variant entre 0-4500 pieds(0-1371.6 m).In Canada,also certified for installation in a bedroom or a bedsitting room/Aussi certifie pour installation dans une chambre a toucher ou une salle de sejour.This appliance must be installed in accordance with local codes,if any;if none,follow the current CAN/CGA-B149(Canada),or ANSI Z223.1(USA)Installation Codes.Installer l'appareil selon les codes ou reglements locaux,ou,en('absence de tels reglements,selon les codes d'installation CAN/CGA-B149(Canada),or ANSI Z223.1 (USA)en vigeur. MANUFACTURED(MOBILE)HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,manufactured(mobile)home where not prohibited by local codes.See owners manual for details. FABRIQUEZ(MOBILE)MAISON: Cet appareil doit etre utilise uniquement avec le type de gaz indique sur la plaque signaletique et peut etre installs dans une maison prefabriquee(mobile)installee a demeure si les reglements locaux le permettent.Voir la notice du proprietaire pour plus de details.Cet appareil ne peut etre converti a d'autres gaz sauf si une trousse de conversion certifiee est utilisee. Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH(in CANADA),and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR,Part 3280,or the current Standard for Fire Safety Criteria for Manufactured Home Installations,Sites,and Communities ANSI/NFPA 501A,(in the U.S.A.). Cet appareil diot etre installs conformement aux exigences de la norme CAN/CSA Z240 MH en vigueur de I'ACNOR,Installations de gaz dans les Constructions Mobiles. FOR USE WITH THE GLASS CERTIFIED WITH THE APPLIANCE ONLY/POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIEES AVEC L'APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES/CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Fireplace Products Ltd. Left and Right side are determined when facing the front of the appliance./Les cotes droit et gauche se determinent Duncan,British Columbia, en se mettant devant l'appareil et en lui faisant face. Top,Back and Side Standoffs I Sommet,Arriere et Cote Butee 0 in./0 po. (0 mm) Canada Sidewall to Appliance/Du mur lateral a('appareil 0 in./0 po. (0 mm) i Ceiling to Appliance/Plafond a l'appareil 0 in./0 po. (0 mm) Mantel to Appliance/Du manteau al'appareil 0 in./0 po. (0 mm) DATE OF MANUFACTURE Maximum Mantel Extension/Allongement maximum du manteau 0 in./0 po. (0 mm) *See Installation Manual for more detail/Voyez des Directive de('Installation pour plus detaux. Mantel Supports/Supports du manteau 0 in./0 po. (0 mm) JAN FEB MAR APR 2018 Vent Pipe/Dechargez le Tuyau 0 in./0 po. (0 mm) WARNING: Improper installation,adjustment,alteration,service or maintenance can cause injury or property damage.Refer MAY JUN JUL AUG 2019 to the owner's information manual provided with this appliance.For assistance or additional information,consult a qualified installer,service agency or the gas supplier. AVERTISSEMENT: Une installation,un reglage,une modification,une reparation ou un entretien mal effectue peut causer SEP OCT NOV DEC 2020 des dommages materiels ou des blessures.Voir la notice de l'utilisateur qui accompgne l'appareil.Pour de('aide ou des renseignements supplementaires,consultez un installateur,un technicien agree ou le fournisseur de gaz. 101218 568000069 7FT Architectural Series RECEIVED 04/05/ 22 310521-56 Architectural Series 51 100005181 TOWN&COUNTRY NIII LUXUASPEN BUILDING DEPARTMENT RECEIVESI�L�i' 11 08/ie/2022 J Foscookosiumm 04/05/2022 ASPEN BUILDING DEPARTMENT `.vF_R(,j VENTED GAS FIREPLACE-NOT FOR USE WITH SOLID FUEL FOYER AU GAZ A EVACUATION-NE PAS UTILISER AVEC DU 728 COMBUSTIBLE SOLIDE C(-LC)US THIS IS A DECORATIVE PRODUCT AND IS NOT INTENDED P.4.1-15 Efficiency:17.2% ! /ll t���� TO BE USED AS A HEATING APPLIANCE. This Appliance is Equipped pp q pped For Use With / Cet Appareil est Equipe Pour Utilise Avec: TOWN&COUNTRY ANSI Z21.50/CSA 2.22(2016)Vented Decorative Gas Appliance. NATURAL GAS/ L.P.GAS/ FIREPLACES' Certified for/Certifie pour Canada and U.S.A. DU GAZ NATUREL ■ DU GAZ L.P. MODEL/ ■ FOR USE WITH/ NATURAL.GAS/ L.P GAS/ MODELE: EN CASE D'EMPLOI AVEC: DU GAZ NATUREL DU GAZ L.P. 8FT ARCHITECTURAL Minimum supply pressure/Pression minimum d'alimentation: 5.0 in/wc/5.0 po/c.e. 12.5 in/wc/12.5 po/c.e. (For the purpose of input adjustment/dans le but de regler I'alimenation) (1.24 kPa) (3.11 kPa) SERIES Maximum supply pressure/Pression maximum d'alimentation: 7.0 in/wc/7.0 po/c.e. 13.9 in/wc/13.9 po/c.e. (1.74 kPa) (3.45 kPa) SERIES/ A Manifold pressure/Pression de la tuyauterie: Maximum 3.50 in/wc/3.50 po/c.e. 11.0 in/wc/13.9 po/c.e. SERIF: Fi (0.87 kPa) (2.73 kPa) Orifice Size/Diametre de l'injectuer: NB X4 LB X4 MADE IN CANADA Input BTU/hr(kW)/Entree BTU/h(kW): Max.:128,000 (37.51) Max.:128,000 (37.51) FABRIQUE AU CANADA Blower electrical rating: 115v,60hz,5.9 A/Normes electriques du ventilateur: 115v,60hz,5.9 A This appliance equipped for altitudes 0-4500 ft.(0-1371.6 m)/Cet unite est congu pour des altitudes variant entre 0-4500 pieds(0-1371.6 m).In Canada,also certified for installation in a bedroom or a bedsitting room/Aussi certifie pour installation dans une chambre a coucher ou une salle de sejour.This appliance must be installed in accordance with local codes,if any;if none,follow the current CAN/CGA-B149(Canada),or ANSI Z223.1(USA)Installation Codes.Installer ('appareil selon les codes ou reglements locaux,ou,en('absence de tels reglements,selon les codes d'installation CAN/CGA-B149(Canada),or ANSI Z223.1 (USA)en vigeur. MANUFACTURED(MOBILE)HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,manufactured(mobile)home where not prohibited by local codes.See owners manual for details. FABRIQUEZ(MOBILE)MAISON: Cet appareil doit etre utilise uniquement avec le type de gaz indique sur la plaque signaletique et peut titre installs dans une maison prefabriquee(mobile)installee a demeure si les reglements locaux le permettent.Voir la notice du proprietaire pour plus de details.Cet appareil ne peut etre converti a d'autres gaz sauf si une trousse de conversion certifiee est utilisee. Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH(in CANADA),and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR,Part 3280,or the current Standard for Fire Safety Criteria for Manufactured Home Installations,Sites,and Communities ANSI/NFPA 501A,(in the U.S.A.). Cet appareil diot etre installs conformement aux exigences de la norme CAN/CSA Z240 MH en vigueur de I'ACNOR,Installations de gaz dans les Constructions Mobiles. FOR USE WITH THE GLASS CERTIFIED WITH THE APPLIANCE ONLY/POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIEES AVEC L'APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES/CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Fireplace Products Ltd. Left and Right side are determined when facing the front of the appliance./Les cotes droit et gauche se determinent Duncan,British Columbia, en se mettant devant('appareil et en lui faisant face. Top,Back and Side Standoffs/Sommet,Arriere et Cote Butee 0 in./0 po. (0 mm) Canada Sidewall to Appliance/Du mur lateral a('appareil 0 in./0 po. (0 mm) Ceiling to Appliance/Plafond a('appareil 0 in./0 po. (0 mm) DATE OF MANUFACTURE Mantel to Appliance/Du manteau al'appareil 0 in./0 po. (0 mm) Maximum Mantel Extension/Allongement maximum du manteau 0 in./0 po. (0 mm) *See Installation Manual for more detail/Voyez des Directive de('Installation pour plus detaux. Mantel Supports/Supports du manteau 0 in./0 po. (0 mm) JAN FEB MAR APR 2018 Vent Pipe/Dechargez le Tuyau 0 in./0 po. (0 mm) WARNING: Improper installation,adjustment,alteration,service or maintenance can cause injury or property damage.Refer MAY JUN JUL AUG 2019 to the owner's information manual provided with this appliance.For assistance or additional information,consult a qualified installer,service agency or the gas supplier. AVERTISSEMENT: Une installation,un reglage,une modification,une reparation ou un entretien mal effectue peut causer SEP OCT NOV DEC 2020 des dommages materiels ou des blessures.Voir la notice de l'utilisateur qui accompgne('appareil.Pour de('aide ou des renseignements supplementaires,consultez un installateur,un technicien agree ou le fournisseur de gaz. 101218 568000070 8FT Architectural Series RECEIVED 04/05/2022 r TOWN&CO TRY 100005181 52 Architectural Series 310521-56 LUXURY FIREPLACESASPEN BUILDING DEPARTMENT RECEIVED ri1109 peacatmatima 04/05/2022 m' ASPEN BUILDING DEPARTMENT RECEIVED 04/05/2022 Blank ASPEN BUILDING DEPARTMENT RECEIVED ri1109 peacatmatima 04/05/2022 m' ASPEN BUILDING DEPARTMENT RECEIVED 04/05/2022 Blank ASPEN BUILDING DEPARTMENT RECEIVED ri1109 peacatmatima 04/05/2022 m' ASPEN BUILDING DEPARTMENT RECEIVED 04/05/2022 Blank ASPEN BUILDING DEPARTMENT RECEIVED - /OLEME 0 49 ,22 right PaPaefffdrfgfgy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. 4?4ij TOWN & COUNTRY LUXURY FIREPLACES For technical support, contact your retailer. Web site: www.townandcountryfireplaces.com 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada 04/05/2022 ASPEN BUILDING DEPARTMENT