HomeMy WebLinkAboutFile Documents.729 W Francis St.0052-2022-BRES (14) Specifications MEZZO36
Please consult the manufacturer's
H EAT&GLO, installation manual for all details and M EZZO36
No one builds a better fire requirements before making a final 36" Direct Vent Gas Fireplace
design layout decision.
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH GLASS SIZE
Actual Framing Actual Framing Actual Framing Actual Framing
MEZZO36 35-1/2 x 12-1/2
46-3/16 48-1/4 46-3/16 48-1/4 41-3/4 42 17-1/8 18-1/4
Top
< 46-3/16"[1173] 1"[25]
� 1 1
18-5/8" l e �� �J
[473117-1/8" O O It)
�) 0 0 -
[435] . \� 8-9/16"[218]
8"[203] t
CENTERED ON APPLIANCE /
/ A
r 49-1/2"[1257]
39-1/4"[997]
I __ I A 1 ,
A 42-1/2„
[1080] 63"[1600]
36 5/8" Ti --- - v .
[930] 61] 5-5/824-1/2 [397]23-3/4" 622[603] L::: ' "
[ ] — _ i
I j60] ui' __ :� �. = 4"�_ •
v i iI v i22s] y �� I
� y [102]
�_ .. ° °
2-3/4" �8[21sj„I` [18]„ GAS ACCESS �8�211g]
[70] ELECTRICAL ACCESS
Left Front Right
BEFORE FRAMING, PLEASE NOTE:
A minimum of 18" of vertical venting is required before attaching any elbow to the appliance.
RECEIVED
05/05/2022
Additional information can be found online at www.heatnglo.com ASPEN
BUILDING DEPARTMENT
Decorative Fronts Dimensions and Framing MEZZ036
FRONT DIMENSIONS
39"[991 f .. 1
MIN
5/8"[16]
E't"" [19" 27-1/4" illf8"
3-1/8" 26-1/4" �[483] 1[333][635] 16-3/4" [667 Iy [3y0]
It
[181] 29-1/8"[740] .
37-3/16"[945] 36-3/4"[933] ' L4-36-7/16"[926]
40-5/16"[1024] I� 42-3/4"[1089] 45-5/8"[1159]
Clean Face Trim Loft Forge Front Quattro Front
• Rectangular holes on • Rectangular holes on • Rectangular holes on
bottom of access panel bottom of access panel bottom of access panel
should be covered. must be exposed. must be exposed.
• Approved for 0ff-4ff • ONLY approved for 0"-1ff • ONLY approved for 0"-1ff
finishing material on finishing material on finishing material on
inside fit method overlap fit method overlap fit method
• If finishing materials are 0-1"
thick, the outer trim ring
should be adjusted
out so that the trim ring
overlaps the finishing
material. This is intended to
provide the cleanest look.
• If finishing materials are 1-4"
thick, install the trim ring
all the way in. Finishing
materials may not extend
past the outside edge of
the trim ring.
FINISHED OPENING DIMENSIONS
1 _ 1 [ ._, 1
•
•
•
•
•
® < 39-1/8"[994] > < 39-1/8"[994] >
1 -oo- y_,�� , .—,.. , .—.�, , .—.l. .+"� r„ _„ _„ _' J •�I
I1
15-3/4"
[400] FIREPLACE VIEWING AREA 1[438] FIREPLACE VIEWING AREA
J
•
- - - , • ,
v.
. L
•
•
•
•
Inside Fit Method Overlap Fit Method
(Clean Face Trim) (Loft Forge, Quattro)
RE( IVED
05/05/2022
HEAT6GLO
No one buildsa better fire ASPEN
BUILDING DEPARTMENT
Specifications MEZZ036
APPLIANCE LOCATION FRAMING DIMENSION
rII�24-1/2" 11.,I`[622] [21] t i 'I,-`, [254
'48-1/4"[1226]'^ 1111111111111111.1111111111
� �If�.
[1588" [25] �II
[1588] 8-1/4" See clearances IIIII
[122 in install manual I
Al/" Refer to Install manual for hearth, 1
2239] mantel and wall projection I
/j information. t �'
If a Passive Heat,Heat-Zone or
Heat Out will be installed,refer 48-1/4" .I I!r
install manual for instructions. [1226r
18 in.(457 mm)required when
Passive Heat Side Discharge Kit is 1 �� I=
installed.Refer to the Passive HeatI
kit instructions for more information.
HEADER
DEPTH*
48-1/4"[1226*S � 42"
I�Ip� 1]476] III\ 11067]
L [176]
WALL PENETRATION 14664j/IUII`M.ii
Do not pack with [11226] �i Ai
insulation or D. .,
other material Ai -- APPLIANCE MAY BE INSTALLED OFF OF FLOOR***
d���� * Adjust framing dimensions for interior sheathing(such as sheetrock)
��E **Header depth not to exceed 3-1/2".
���a ***If appliance is installed off the floor,maintain required clearances to combustibles
10"
12" ����� Construct platform in accordance with local building codes.
III CLEARANCES TO COMBUSTIBLES
r '"
.,�
64"
[1626] 1...,.e Shows center of vent framing
L--" hole for top venting.Center of hole
s 1"[25]above center of horizontal
vent pipe. 31"[787]
Top of
Fireplace
MANTEL PROJECTIONS - COMBUSTIBLE Opening to
Gelling
0"
NOTE: All measurements in inches. •
•
WITHOUT MAX. MAX.
13 WITH •
PASSIVE 9 PASSIVE 16
HEAT ' HEAT * ss-u2^
1410]
a3^ • Bottom 01
29
I 2a I
[1210] �1"[26] Ce
Fireplailince to
g
IF
1a,93022 Tr 10 I 1"125]
. 9
IIsIsil1
MEASUREMENTS FROM TOP EDGE MANTEL LEG/WALL PROJECTIONS
MEASUREMENT FROM
TOPP EDGE OPENING
OF THE APPLIANCE OPENING COMBUSTIBLE OR NON-COMBUSTIBLE
Measurement from top edge opening Measurement from top edge of opening Note:Clearance from Note:Clearance from
to bottom of appliance s24-1/2IN. obottee of appliance=341M IN. opening to opening to
perpendicular wall perpendicular wall
0 O
MANTEL PROJECTIONS - NON-COMBUSTIBLE Top View Top View
NOTE: All measurements in inches. 4-1/2^ T [•,,
OVERLAP FIT INSIDE FIT
minimum 3 ft.maximum / minimum UNLIMITED
MAX.
FIREPLACE OPENING FIREPLACE OPENING
MAX. 18 See Appliance dimension diagram See Appliance dimension diagram
in install manual-Dimension B in install manual-Dimension B
is
Acceptable on both sides of opening
J 7
e J e Product information provided is
s 5 1 PRODUCT LISTING CODES not complete and is subject to
4
1s I j 11 change without notice.Product
al } I
11 - D US ANSI Z21.88-2017 installation must adhere strictly
2 I s 10 •
4 9 to instructions accompanying
e�Li 6 1 18111
CAN CSA 2.33-2017 product to avoid risk of fire and
— ,,,, Omura Deusm UL307B potential injury. IVED
OF THE APPLIAMENTSNCE
FROM TOP EDGE
OF THE APPLIANCE OPENINGMEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING Additional information can be found online at www.heatn o. 4
Measurement from op edge of opening
• o bottom of appliance s24-1/2 IN. Measurement from top edge of opening
e bottom of appliance•244/21N. 0 5/0 5/2 0 2 2
Lakeville,MN Web:heatnglo.com C u8 LISTED
HEAT&G L O Phone: 888-427-3973 952-985-6000 AS L N
No one builds a better fire B U I LMMER#I T NT